Search results for: aortic valve stenosis
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 325

Search results for: aortic valve stenosis

265 Surface Adjustments for Endothelialization of Decellularized Porcine Pericardium

Authors: M. Markova, E. Filova, O. Kaplan, R. Matejka, L. Bacakova

Abstract:

The porcine pericardium is used as a material for cardiac and aortic valves substitutes. Current biological aortic heart valve prosthesis have a limited lifetime period because they undergo degeneration. In order to make them more biocompatible and prolong their lifetime it is necessary to reseed the decellularized prostheses with endothelial cells and with valve interstitial cells. The endothelialization of the prosthesis-surface may be supported by suitable chemical surface modification of the prosthesis. The aim of this study is to prepare bioactive fibrin layers which would both support endothelialization of porcine pericardium and enhance differentiation and maturation of the endothelial cells seeded. As a material for surface adjustments we used layers of fibrin with/without heparin and some of them with adsorbed or chemically bound FGF2, VEGF or their combination. Fibrin assemblies were prepared in 24-well cell culture plate and were seeded with HSVEC (Human Saphenous Vein Endothelial Cells) at a density of 20,000 cells per well in EGM-2 medium with 0.5% FS and without heparin, without FGF2 and without VEGF; medium was supplemented with aprotinin (200 U/mL). As a control, surface polystyrene (PS) was used. Fibrin was also used as homogeneous impregnation of the decellularized porcine pericardium throughout the scaffolds. Morphology, density, and viability of the seeded endothelial cells were observed from micrographs after staining the samples by LIVE/DEAD cytotoxicity/viability assay kit on the days 1, 3, and 7. Endothelial cells were immunocytochemically stained for proteins involved in cell adhesion, i.e. alphaV integrin, vinculin, and VE-cadherin, markers of endothelial cells differentiation and maturation, i.e. von Willebrand factor and CD31, and for extracellular matrix proteins typically produced by endothelial cells, i.e. type IV collagen and laminin. The staining intensities were subsequently quantified using a software. HSVEC cells grew on each of the prepared surfaces better than on control surface. They reached confluency. The highest cell densities were obtained on the surface of fibrin with heparin and both grow factors used together. Intensity of alphaV integrins staining was highest on samples with remained fibrin layer, i.e. on layers with lower cell densities, i.e. on fibrin without heparin. Vinculin staining was apparent, but was rather diffuse, on fibrin with both FGF2 and VEGF and on control PS. Endothelial cells on all samples were positively stained for von Willebrand factor and CD31. VE-cadherin receptors clusters were best developed on fibrin with heparin and growth factors. Significantly stronger staining of type IV collagen was observed on fibrin with heparin and both growth factors. Endothelial cells on all samples produced laminin-1. Decellularized pericardium was homogeneously filled with fibrin structures. These fibrin-modified pericardium samples will be further seeded with cells and cultured in a bioreactor. Fibrin layers with/without heparin and with adsorbed or chemically bound FGF2, VEGF or their combination are good surfaces for endothelialization of cardiovascular prostheses or porcine pericardium based heart valves. Supported by the Ministry of Health, grants No15-29153A and 15-32497A, and the Grant Agency of the Czech Republic, project No. P108/12/G108.

Keywords: aortic valves prosthesis, FGF2, heparin, HSVEC cells, VEGF

Procedia PDF Downloads 237
264 Effects of Turbulence Penetration on Valve Leakage in Nuclear Reactor Coolant System

Authors: Gupta Rajesh, Paudel Sagar, Sharma Utkarsh, Singh Amit Kumar

Abstract:

Thermal stratification has drawn much attention because of the malfunctions at various nuclear plants in U.S.A that raised significant safety concerns. The concerns due to this phenomenon relate to thermal stresses in branch pipes connected to the reactor coolant system piping. This stress limits the lifetime of the piping system, and even leading to penetrating cracks. To assess origin of valve damage in the pipeline, it is essential to determine the effect of turbulence penetration on valve leakage; since stratified flow is generally generated by turbulent penetration or valve leakage. As a result, we concluded with the help of coupled fluent-structural analysis that the pipe with less turbulence has less chance of failure there by requiring less maintenance.

Keywords: nuclear reactor coolant system, thermal stratification, turbulent penetration, coupled fluent-structural analysis, Von-Misses stress

Procedia PDF Downloads 262
263 Development of Piezoelectric Gas Micropumps with the PDMS Check Valve Design

Authors: Chiang-Ho Cheng, An-Shik Yang, Hon-Yi Cheng, Ming-Yu Lai

Abstract:

This paper presents the design and fabrication of a novel piezoelectric actuator for a gas micropump with check valve having the advantages of miniature size, light weight and low power consumption. The micropump is designed to have eight major components, namely a stainless steel upper cover layer, a piezoelectric actuator, a stainless steel diaphragm, a PDMS chamber layer, two stainless steel channel layers with two valve seats, a PDMS check valve layer with two cantilever-type check valves and an acrylic substrate. A prototype of the gas micropump, with a size of 52 mm × 50 mm × 5.0 mm, is fabricated by precise manufacturing. This device is designed to pump gases with the capability of performing the self-priming and bubble-tolerant work mode by maximizing the stroke volume of the membrane as well as the compression ratio via minimization of the dead volume of the micropump chamber and channel. By experiment apparatus setup, we can get the real-time values of the flow rate of micropump and the displacement of the piezoelectric actuator, simultaneously. The gas micropump obtained higher output performance under the sinusoidal waveform of 250 Vpp. The micropump achieved the maximum pumping rates of 1185 ml/min and back pressure of 7.14 kPa at the corresponding frequency of 120 and 50 Hz.

Keywords: PDMS, check valve, micropump, piezoelectric

Procedia PDF Downloads 426
262 Application of Exhaust Gas-Air Brake System in Petrol and Diesel Engine

Authors: Gurlal Singh, Rupinder Singh

Abstract:

The possible role of the engine brake is to convert a power-producing engine into a power-absorbing retarding mechanism. In this braking system, exhaust gas (EG) from the internal combustion (IC) engines is used to operate air brake in the automobiles. Airbrake is most used braking system in vehicles. In the proposed model, instead of air brake, EG is used to operate the brake lever and stored in a specially designed tank. This pressure of EG is used to operate the pneumatic cylinder and brake lever. Filters used to remove the impurities from the EG, then it is allowed to store in the tank. Pressure relief valve is used to achieve a specific pressure in the tank and helps to avoid further damage to the tank as well as in an engine. The petrol engine is used in the proposed EG braking system. The petrol engine is chosen initially because it produces less impurity in the exhaust than diesel engines. Moreover, exhaust brake system (EBS) for the Diesel engines is composed of gate valve, pneumatic cylinder and exhaust brake valve with the on-off solenoid. Exhaust brake valve which is core component of EBS should have characteristics such as high reliability and long life. In a diesel engine, there is butterfly valve in exhaust manifold connected with solenoid switch which is used to on and off the butterfly valve. When butterfly valve closed partially, then the pressure starts built up inside the exhaust manifold and cylinder that actually resist the movement of piston leads to crankshaft getting stops resulting stopping of the flywheel. It creates breaking effect in a diesel engine. The exhaust brake is a supplementary breaking system to the service brake. It is noted that exhaust brake increased 2-3 fold the life of service brake may be due to the creation of negative torque which retards the speed of the engine. More study may also be warranted for the best suitable design of exhaust brake in a diesel engine.

Keywords: exhaust gas, automobiles, solenoid, airbrake

Procedia PDF Downloads 229
261 A Measurement Device of Condensing Flow Rate, an Order of MilliGrams per Second

Authors: Hee Joon Lee

Abstract:

There are many difficulties in measuring a small flow rate of an order of milli grams per minute (LPM) or less using a conventional flowmeter. Therefore, a flow meter with minimal loss and based on a new concept was designed as part of this paper. A chamber was manufactured with a level transmitter and an on-off control valve. When the level of the collected condensed water reaches the top of the chamber, the valve opens to allow the collected water to drain back into the tank. To allow the water to continue to drain when the signal is lost, the valve is held open for a few seconds by a time delay switch and then closed. After an examination, the condensing flow rate was successfully measured with the uncertainty of ±5.7% of the full scale for the chamber.

Keywords: chamber, condensation, flow meter, milli-grams

Procedia PDF Downloads 254
260 Human Coronary Sinus Venous System as a Target for Clinical Procedures

Authors: Wiesława Klimek-Piotrowska, Mateusz K. Hołda, Mateusz Koziej, Katarzyna Piątek, Jakub Hołda

Abstract:

Introduction: The coronary sinus venous system (CSVS), which has always been overshadowed by the coronary arterial tree, has recently begun to attract more attention. Since it is a target for clinicians the knowledge of its anatomy is essential. Cardiac resynchronization therapy, catheter ablation of cardiac arrhythmias, defibrillation, perfusion therapy, mitral valve annuloplasty, targeted drug delivery, and retrograde cardioplegia administration are commonly used therapeutic methods involving the CSVS. The great variability in the course of coronary veins and tributaries makes the diagnostic and therapeutic processes difficult. Our aim was to investigate detailed anatomy of most common clinically used CSVS`s structures: the coronary sinus with its ostium, great cardiac vein, posterior vein of the left ventricle, middle cardiac vein and oblique vein of the left atrium. Methodology: This is a prospective study of 70 randomly selected autopsied hearts dissected from adult humans (Caucasian) aged 50.1±17.6 years old (24.3% females) with BMI=27.6±6.7 kg/m2. The morphology of the CSVS was assessed as well as its precise measurements were performed. Results: The coronary sinus (CS) with its ostium was present in all hearts. The mean CS ostium diameter was 9.9±2.5mm. Considered ostium was covered by its valve in 87.1% with mean valve height amounted 5.1±3.1mm. The mean percentage coverage of the CS ostium by the valve was 56%. The Vieussens valve was present in 71.4% and was unicuspid in 70%, bicuspid in 26% and tricuspid in 4% of hearts. The great cardiac vein was present in all cases. The oblique vein of the left atrium was observed in 84.3% of hearts with mean length amounted 20.2±9.3mm and mean ostium diameter 1.4±0.9mm. The average length of the CS (from the CS ostium to the Vieussens valve) was 31.1±9.5mm or (from the CS ostium to the ostium of the oblique vein of the left atrium) 28.9±10.1mm and both were correlated with the heart weight (r=0.47; p=0.00 and r=0.38; p=0.006 respectively). In 90.5% the ostium of the oblique vein of the left atrium was located proximally to the Vieussens valve, in remaining cases was distally. The middle cardiac vein was present in all hearts and its valve was noticed in more than half of all the cases (52.9%). The posterior vein of the left ventricle was observed in 91.4% of cases. Conclusions: The CSVS is vastly variable and none of basic hearts parameters is a good predictor of its morphology. The Vieussens valve could be a significant obstacle during CS cannulation. Caution should be exercised in this area to avoid coronary sinus perforation. Because of the higher incidence of the presence of the oblique vein of the left atrium than the Vieussens valve, the vein orifice is more useful in determining the CS length.

Keywords: cardiac resynchronization therapy, coronary sinus, Thebesian valve, Vieussens valve

Procedia PDF Downloads 270
259 The Microstructural Evolution of X45CrNiW189 Valve Steel during Hot Deformation

Authors: A. H. Meysami

Abstract:

In this paper, the hot compression tests were carried on X45CrNiW189 valve steel (X45) in the temperature range of 1000–1200°C and the strain rate range of 0.004–0.5 s^(-1) in order to study the high temperature softening behavior of the steel. For the exact prediction of flow stress, the effective stress - effective strain curves were obtained from experiments under various conditions. On the basis of experimental results, the dynamic recrystallization fraction (DRX), AGS, hot deformation and activation energy behavior were investigated. It was found that the calculated results were in a good agreement with the experimental flow stress and microstructure of the steel for different conditions of hot deformation.

Keywords: X45CrNiW189, valve steel, hot compression test, dynamic recrystallization, hot deformation

Procedia PDF Downloads 253
258 Numerical Investigation of the Electromagnetic Common Rail Injector Characteristics

Authors: Rafal Sochaczewski, Ksenia Siadkowska, Tytus Tulwin

Abstract:

The paper describes the modeling of a fuel injector for common rail systems. A one-dimensional model of a solenoid-valve-controlled injector with Valve Closes Orifice (VCO) spray was modelled in the AVL Hydsim. This model shows the dynamic phenomena that occur in the injector. The accuracy of the calibration, based on a regulation of the parameters of the control valve and the nozzle needle lift, was verified by comparing the numerical results of injector flow rate. Our model is capable of a precise simulation of injector operating parameters in relation to injection time and fuel pressure in a fuel rail. As a result, there were made characteristics of the injector flow rate and backflow.

Keywords: common rail, diesel engine, fuel injector, modeling

Procedia PDF Downloads 392
257 Morphology and Risk Factors for Blunt Aortic Trauma in Car Accidents: An Autopsy Study

Authors: Ticijana Prijon, Branko Ermenc

Abstract:

Background: Blunt aortic trauma (BAT) includes various morphological changes that occur during deceleration, acceleration and/or body compression in traffic accidents. The various forms of BAT, from limited laceration of the intima to complete transection of the aorta, depends on the force acting on the vessel wall and the tolerance of the aorta to injury. The force depends on the change in velocity, the dynamics of the accident and of the seating position in the car. Tolerance to aortic injury depends on the anatomy, histological structure and pathomorphological alterations due to aging or disease of the aortic wall.An overview of the literature and medical documentation reveals that different terms are used to describe certain forms of BAT, which can lead to misinterpretation of findings or diagnoses. We therefore, propose a classification that would enable uniform systematic screening of all forms of BAT. We have classified BAT into three morphologycal types: TYPE I (intramural), TYPE II (transmural) and TYPE III (multiple) aortic ruptures with appropriate subtypes. Methods: All car accident casualties examined at the Institute of Forensic Medicine from 2001 to 2009 were included in this retrospective study. Autopsy reports were used to determine the occurrence of each morphological type of BAT in deceased drivers, front seat passengers and other passengers in cars and to define the morphology of BAT in relation to the accident dynamics and the age of the fatalities. Results: A total of 391 fatalities in car accidents were included in the study. TYPE I, TYPE II and TYPE III BAT were observed in 10,9%, 55,6% and 33,5%, respectively. The incidence of BAT in drivers, front seat and other passengers was 36,7%, 43,1% and 28,6%, respectively. In frontal collisions, the incidence of BAT was 32,7%, in lateral collisions 54,2%, and in other traffic accidents 29,3%. The average age of fatalities with BAT was 42,8 years and of those without BAT 39,1 years. Conclusion: Identification and early recognition of the risk factors of BAT following a traffic accident is crucial for successful treatment of patients with BAT. Front seat passengers over 50 years of age who have been injured in a lateral collision are the most at risk of BAT.

Keywords: aorta, blunt trauma, car accidents, morphology, risk factors

Procedia PDF Downloads 485
256 Pulmonary Valve Papillary Fibroelastoma: A Case Report of a Fibroelastoma Presenting as a Pulmonary Embolism

Authors: Frazer Kirk, Matthew Yong, Peter Williams, Andrie Strobel

Abstract:

Pulmonary valve papillary fibroelastoma is an exceedingly rare pathology. The experience and literature regarding them are largely anecdotal and based on sporadic, single case reports. Throughout their known history, two features remain salient that they are classically asymptomatic and found incidentally. The demographic profile of those affected is unclear, as reports regarding those affected are mixed, and there is no clear gender or age predominance, although there is some suggestion of a predisposition to affect females. Nor has there been a well-structured epidemiological study of the entity. Interestingly they are becoming more common on peri-mortum examination. Here-after we describe our experience with a symptomatic presentation of pulmonary papillary fibroelastoma masquerading as a pulmonary embolism and its subsequent assessment and management, with intraoperative photography and echocardiography for reference.

Keywords: cardiac tumor, pulmonary valve, fibroelastoma, cardiac surgery

Procedia PDF Downloads 181
255 Predictors of Clinical Failure After Endoscopic Lumbar Spine Surgery During the Initial Learning Curve

Authors: Daniel Scherman, Daniel Madani, Shanu Gambhir, Marcus Ling Zhixing, Yingda Li

Abstract:

Objective: This study aims to identify clinical factors that may predict failed endoscopic lumbar spine surgery to guide surgeons with patient selection during the initial learning curve. Methods: This is an Australasian prospective analysis of the first 105 patients to undergo lumbar endoscopic spine decompression by 3 surgeons. Modified MacNab outcomes, Oswestry Disability Index (ODI) and Visual Analogue Score (VAS) scores were utilized to evaluate clinical outcomes at 6 months postoperatively. Descriptive statistics and Anova t-tests were performed to measure statistically significant (p<0.05) associations between variables using GraphPad Prism v10. Results: Patients undergoing endoscopic lumbar surgery via an interlaminar or transforaminal approach have overall good/excellent modified MacNab outcomes and a significant reduction in post-operative VAS and ODI scores. Regardless of the anatomical location of disc herniations, good/excellent modified MacNab outcomes and significant reductions in VAS and ODI were reported post-operatively; however, not in patients with calcified disc herniations. Patients with central and foraminal stenosis overall reported poor/fair modified MacNab outcomes. However, there were significant reductions in VAS and ODI scores post-operatively. Patients with subarticular stenosis or an associated spondylolisthesis reported good/excellent modified MacNab outcomes and significant reductions in VAS and ODI scores post-operatively. Patients with disc herniation and concurrent degenerative stenosis had generally poor/fair modified MacNab outcomes. Conclusion: The outcomes of endoscopic spine surgery are encouraging, with a low complication and reoperation rate. However, patients with calcified disc herniations, central canal stenosis or a disc herniation with concurrent degenerative stenosis present challenges during the initial learning curve and may benefit from traditional open or other minimally invasive techniques.

Keywords: complications, lumbar disc herniation, lumbar endoscopic spine surgery, predictors of failed endoscopic spine surgery

Procedia PDF Downloads 96
254 Congenital Malformations in Neonate Dogs in the Sao Paulo State University Veterinary Hospital, Botucatu, Sao Paulo, Brazil

Authors: Maria Lucia G. Lourenco, Keylla H. N. P. Pereira, Viviane Y. Hibaru, Fabiana F. Souza, Joao C. P. Ferreira, Simone B. Chiacchio, Luiz H. A. Machado

Abstract:

Congenital malformations are organ defects due to genetic or teratogenic causes, which can lead to high mortality in dog litters. This study assessed and described the congenital malformations in newborn dogs. The study included litters attend in the São Paulo State University (UNESP) Veterinary Hospital, Botucatu, Sao Paulo, Brazil. One hundred seventy-eight litters and 803 newborns were evaluated. The occurrence of litters with malformations was 24.7%, and of newborns was 6.7%. Twenty-seven different malformations were registered: anasarca, anal atresia, cleft lip, cleft palate, duplicated right ribcage, equinovarus, exencephaly, gastroschisis, hydrocephaly, lissencephaly, macroglossia, microphthalmia, mitral valve dysplasia, omphalocele, eyelid agenesis, persistent urachus, polydactyly, pulmonary hypoplasia, pulmonary valve stenosis, rectovaginal fistula, agenesis of abdominal muscles, rib hypoplasia, scoliosis, segmental aplasia of the intestines, tricuspid valve dysplasia, unilateral kidney agenesis, and vaginal atresia. 68.7% of newborns died as a result of malformations. The pure breeds with the highest chances of manifesting malformations in contrast with mixed breeds were French Bulldog, Pug, English Bulldog, Rottweiler, German Spitz, Pinscher, Pitbull, Yorkshire Terrier, and Shih-Tzu. Significant values (P<0.05) occurred in races French Bulldogs and Pugs. The causes of congenital disabilities are possibly related to hereditary genetic factors considering that the highest incidence of malformations was observed among purebreds. There as one case of exposure to a teratogenic agent, but no other mothers were exposed to such agents during pregnancy. Two cases of consanguineal breeding between siblings were reported. The mortality rate was high. Genetic breeding programs for reproduction, avoiding consanguineous mating, care in choosing parents, and avoiding maternal exposure to teratogenic agents are of utmost importance in reducing dog malformations and consequent mortality.

Keywords: congenital defects, teratogenesis, canine neonatology, newborn puppy

Procedia PDF Downloads 108
253 Study of Cavitation Phenomena Based on Flow Visualization Test in 3-Way Reversing Valve

Authors: Hyo Lim Kang, Tae An Kim, Seung Ho Han

Abstract:

A 3-way reversing valve has been used in automotive washing machines to remove remaining oil and dirt on machined engine and transmission blocks. It provides rapid and accurate changes of water flow direction without any precise control device. However, due to its complicated bottom-plug shape, a cavitation occurs in a wide range of the bottom-plug in a downstream. In this study, the cavitation index and POC (percent of cavitation) were used to evaluate quantitatively the cavitation phenomena occurring at the bottom-plug. An optimal shape design was carried out via parametric study for geometries of the bottom-plug, in which a simple CAE-model was used in order to avoid time-consuming CFD analysis and hard to achieve convergence. To verify the results of numerical analysis, a flow visualization test was carried out using a test specimen with a transparent acryl pipe according to ISA-RP75.23. The flow characteristics such as the cavitation occurring in the downstream were investigated by using a flow test equipment with valve and pump including a flow control system and high-speed camera.

Keywords: cavitation, flow visualization test, optimal shape design, percent of cavitation, reversing valve

Procedia PDF Downloads 271
252 Characteristics of Patients Undergoing Subclavian Artery Revascularization in Latvia: A Retrospective Analysis

Authors: Majid Shahbazi

Abstract:

Subclavian artery stenosis (SAS) is a common vascular disease that can cause a range of symptoms, from arm fatigue and weakness to ischemic stroke. Revascularization procedures, such as percutaneous transluminal angioplasty and stenting, are widely used to treat SAS and improve blood flow to the affected arm. However, the optimal management of patients with SAS is still unclear, and further research is needed to evaluate the safety and efficacy of different treatment options. This study aims to investigate the characteristics of patients with SAS who underwent revascularization procedures in Latvia (Specifically RAKUS). The research part of this paper aims to describe and analyze the demographics, comorbidities, diagnostic methods, types of revascularization procedures, and antiaggregant therapy used. The goal of this study is to provide insights into the current clinical practice in Latvia and help future treatment decision-makers. To achieve this aim, a retrospective study of 76 patients with SAS who underwent revascularization procedures was performed. After statistical analysis of the data, the study provided insights into the characteristics and management of patients with SAS in Latvia, highlighting the most observed comorbidities in these patients, the preferred diagnostic methods, and the most performed procedures. These findings can inform clinical decision-making and may have implications for the management of patients with subclavian artery stenosis in Latvia.

Keywords: subclavian artery stenosis, revascularization, characteristics of patients, comorbidities, retrospective analysis

Procedia PDF Downloads 69
251 Pressure Surge Analysis for Al Gardabiya Pump Station Phase III of the Man-Made River Project

Authors: Ahmed Bensreti, Mohamed Gouarsha

Abstract:

This paper presents a review of the pressure surge simulations carried out for Phase III of the Man Made River project in Libya with particular emphasis on the transient generated by simultaneous pump trips at Al Gardabiya Pump Station. The omission of the surge vessel check valve and bypass system on the grounds of cost, ease of design, and construction will result in, as expected, increased surge fluctuations as the damping effect in the form was removed. From the hydraulic and control requirements, it is recommended for Al Gardabiya Pump station that the check valve and check valve bypass be included in the final surge vessel design.

Keywords: computational fluid dynamics, surge vessel design, transient surge analysis, water pipe hydraulics

Procedia PDF Downloads 40
250 Economic Load Dispatch with Valve-Point Loading Effect by Using Differential Evolution Immunized Ant Colony Optimization Technique

Authors: Nur Azzammudin Rahmat, Ismail Musirin, Ahmad Farid Abidin

Abstract:

Economic load dispatch is performed by the utilities in order to determine the best generation level at the most feasible operating cost. In order to guarantee satisfying energy delivery to the consumer, a precise calculation of generation level is required. In order to achieve accurate and practical solution, several considerations such as prohibited operating zones, valve-point effect and ramp-rate limit need to be taken into account. However, these considerations cause the optimization to become complex and difficult to solve. This research focuses on the valve-point effect that causes ripple in the fuel-cost curve. This paper also proposes Differential Evolution Immunized Ant Colony Optimization (DEIANT) in solving economic load dispatch problem with valve-point effect. Comparative studies involving DEIANT, EP and ACO are conducted on IEEE 30-Bus RTS for performance assessments. Results indicate that DEIANT is superior to the other compared methods in terms of calculating lower operating cost and power loss.

Keywords: ant colony optimization (ACO), differential evolution (DE), differential evolution immunized ant colony optimization (DEIANT), economic load dispatch (ELD)

Procedia PDF Downloads 417
249 Analysis of Weld Crack of Main Steam Governing Valve Steam Turbine Case

Authors: Sarakorn Sukaviriya

Abstract:

This paper describes the inspection procedure, root cause analysis, the rectification of crack, and how to apply the procedure with other similar plants. During the operation of the steam turbine (620MW), instruments such as speed sensor of steam turbine, the servo valve of main stop valve and electrical wires were malfunction caused by leakage steam from main steam governing valve. Therefore, the power plant decided to shutdown steam turbines for figuring out the cause of leakage steam. Inspection techniques to be applied in this problem were microstructure testing (SEM), pipe stress analysis (FEM) and non-destructive testing. The crack was initially found on main governing valve’s weldment by visual inspection. To analyze more precisely, pipe stress analysis and microstructure testing were applied and results indicated that the crack was intergranular and originated from the weld defect. This weld defect caused the notch with high-stress concentration which created crack and then propagated to steam leakage. The major root cause of this problem was an inappropriate welding process, which created a weld defect. To repair this joint from damage, we used a welding technique by producing refinement of coarse grain HAZ and eliminating stress concentration. After the weldment was completely repaired, other adjacent weldments still had risk. Hence, to prevent any future cracks, non-destructive testing (NDT) shall be applied to all joints in order to ensure that there will be no indication of crack.

Keywords: steam-pipe leakage, steam leakage, weld crack analysis, weld defect

Procedia PDF Downloads 105
248 Systematic Review and Meta-Analysis of Mid-Term Survival, and Recurrent Mitral Regurgitation for Robotic-Assisted Mitral Valve Repair

Authors: Ramanen Sugunesegran, Michael L. Williams

Abstract:

Over the past two decades surgical approaches for mitral valve (MV) disease have evolved with the advent of minimally invasive techniques. Robotic mitral valve repair (RMVr) safety and efficacy has been well documented, however, mid- to long-term data are limited. The aim of this review was to provide a comprehensive analysis of the available mid- to long-term term data for RMVr. Electronic searches of five databases were performed to identify all relevant studies reporting minimum 5-year data on RMVr. Pre-defined primary outcomes of interest were overall survival, freedom from MV reoperation and freedom from moderate or worse mitral regurgitation (MR) at 5-years or more post-RMVr. A meta-analysis of proportions or means was performed, utilizing a random effects model, to present the data. Kaplan-Meier curves were aggregated using reconstructed individual patient data. Nine studies totaling 3,300 patients undergoing RMVr were identified. Rates of overall survival at 1-, 5- and 10-years were 99.2%, 97.4% and 92.3%, respectively. Freedom from MV reoperation at 8-years post RMVr was 95.0%. Freedom from moderate or worse MR at 7-years was 86.0%. Rates of early post-operative complications were low with only 0.2% all-cause mortality and 1.0% cerebrovascular accident. Reoperation for bleeding was low at 2.2% and successful RMVr was 99.8%. Mean intensive care unit and hospital stay were 22.4 hours and 5.2 days, respectively. RMVr is a safe procedure with low rates of early mortality and other complications. It can be performed with low complication rates in high volume, experienced centers. Evaluation of available mid-term data post-RMVr suggests favorable rates of overall survival, freedom from MV reoperation and freedom from moderate or worse MR recurrence.

Keywords: mitral valve disease, mitral valve repair, robotic cardiac surgery, robotic mitral valve repair

Procedia PDF Downloads 59
247 Modern Cardiac Surgical Outcomes in Nonagenarians: A Multicentre Retrospective Observational Study

Authors: Laurence Weinberg, Dominic Walpole, Dong-Kyu Lee, Michael D’Silva, Jian W. Chan, Lachlan F. Miles, Bradley Carp, Adam Wells, Tuck S. Ngun, Siven Seevanayagam, George Matalanis, Ziauddin Ansari, Rinaldo Bellomo, Michael Yii

Abstract:

Background: There have been multiple recent advancements in the selection, optimization and management of cardiac surgical patients. However, there is limited data regarding the outcomes of nonagenarians undergoing cardiac surgery, despite this vulnerable cohort increasingly receiving these interventions. This study describes the patient characteristics, management and outcomes of a group of nonagenarians undergoing cardiac surgery in the context of contemporary peri-operative care. Methods: A retrospective observational study was conducted of patients 90 to 99 years of age (i.e., nonagenarians) who had undergone cardiac surgery requiring a classic median sternotomy (i.e., open-heart surgery). All operative indications were included. Patients who underwent minimally invasive surgery, transcatheter aortic valve implantation and thoracic aorta surgery were excluded. Data were collected from four hospitals in Victoria, Australia, over an 8-year period (January 2012 – December 2019). The primary objective was to assess six-month mortality in nonagenarians undergoing open-heart surgery and to evaluate the incidence and severity of postoperative complications using the Clavien-Dindo classification system. The secondary objective was to provide a detailed description of the characteristics and peri-operative management of this group. Results: A total of 12,358 adult patients underwent cardiac surgery at the study centers during the observation period, of whom 18 nonagenarians (0.15%) fulfilled the inclusion criteria. The median (IQR) [min-max] age was 91 years (90.0:91.8) [90-94] and 14 patients (78%) were men. Cardiovascular comorbidities, polypharmacy and frailty, were common. The median (IQR) predicted in-hospital mortality by EuroSCORE II was 6.1% (4.1-14.5). All patients were optimized preoperatively by a multidisciplinary team of surgeons, cardiologists, geriatricians and anesthetists. All index surgeries were performed on cardiopulmonary bypass. Isolated coronary artery bypass grafting (CABG) and CABG with aortic valve replacement were the most common surgeries being performed in four and five patients, respectively. Half the study group underwent surgery involving two or more major procedures (e.g. CABG and valve replacement). Surgery was undertaken emergently in 44% of patients. All patients except one experienced at least one postoperative complication. The most common complications were acute kidney injury (72%), new atrial fibrillation (44%) and delirium (39%). The highest Clavien-Dindo complication grade was IIIb occurring once each in three patients. Clavien-Dindo grade IIIa complications occurred in only one patient. The median (IQR) postoperative length of stay was 11.6 days (9.8:17.6). One patient was discharged home and all others to an inpatient rehabilitation facility. Three patients had an unplanned readmission within 30 days of discharge. All patients had follow-up to at least six months after surgery and mortality over this period was zero. The median (IQR) duration of follow-up was 11.3 months (6.0:26.4) and there were no cases of mortality observed within the available follow-up records. Conclusion: In this group of nonagenarians undergoing cardiac surgery, postoperative six-month mortality was zero. Complications were common but generally of low severity. These findings support carefully selected nonagenarian patients being offered cardiac surgery in the context of contemporary, multidisciplinary perioperative care. Further, studies are needed to assess longer-term mortality and functional and quality of life outcomes in this vulnerable surgical cohort.

Keywords: cardiac surgery, mortality, nonagenarians, postoperative complications

Procedia PDF Downloads 92
246 Modified Preputial Urethrostomy as a Salvage Procedure in Four Dogs

Authors: Thomas Giansetto, Olivier Broux, Géraldine Bolen, Stéphanie Claeys

Abstract:

Objective: To describe a modified preputial urethrostomy in four dogs. Study design: Short case series. Animals: Four male dogs were treated by the modified preputial urethrostomy, three because of urethral stenosis, and one because of severe complications following perineal urethrostomy. Methods: Four dogs were presented for dysuria and urinary obstruction. secondary to urethral stenosis or tear. Obstruction was treated with a modified preputial urethrostomy. Results: Four dogs had resolution of dysuria with a modified preputial urethrostomy without penile amputation. None of the dogs presented signs of dysuria, urinary tract infection, or dermatitis postoperatively. Two dogs showed signs of urinary incontinence 15 days and one month postoperatively. Conclusion: The modified preputial urethrostomy resulted in a favorable prognosis and may be an alternative to prepubic urethrostomy in male dogs.

Keywords: urethrostomy, preputial, technique, urogenital

Procedia PDF Downloads 128
245 Blood Flow in Stenosed Arteries: Analytical and Numerical Study

Authors: Shashi Sharma, Uaday Singh, V. K. Katiyar

Abstract:

Blood flow through a stenosed tube, which is of great interest to mechanical engineers as well as medical researchers. If stenosis exists in an artery, normal blood flow is disturbed. The deposition of fatty substances, cholesterol, cellular waste products in the inner lining of an artery results to plaque formation .The present study deals with a mathematical model for blood flow in constricted arteries. Blood is considered as a Newtonian, incompressible, unsteady and laminar fluid flowing in a cylindrical rigid tube along the axial direction. A time varying pressure gradient is applied in the axial direction. An analytical solution is obtained using the numerical inversion method for Laplace Transform for calculating the velocity profile of fluid as well as particles.

Keywords: blood flow, stenosis, Newtonian fluid, medical biology and genetics

Procedia PDF Downloads 494
244 Investigation and Analysis of Vortex-Induced Vibrations in Sliding Gate Valves Using Computational Fluid Dynamics

Authors: Kianoosh Ahadi, Mustafa Ergil

Abstract:

In this study, the event of vibrations caused by vortexes and the distribution of induced hydrodynamic forces due to vortexes on the sliding gate valves has been investigated. For this reason, a sliding valve with the help of computational fluid dynamics (CFD) software was simulated in two-dimensional )2D(, where the flow and turbulence equations were solved for three different valve openings (full, half, and 16.7 %) models. The variety of vortexes formed within the vicinity of the valve structure was investigated based on time where the trend of fluctuations and their occurrence regions have been detected. From the gathered solution dataset of the numerical simulations, the pressure coefficient (CP), the lift force coefficient (CL), the drag force coefficient (CD), and the momentum coefficient due to hydrodynamic forces (CM) were examined, and relevant figures were generated were from these results, the vortex-induced vibrations were analyzed.

Keywords: induced vibrations, computational fluid dynamics, sliding gate valves, vortexes

Procedia PDF Downloads 81
243 Development of a New Piezoelectrically Actuated Micropump for Liquid and Gas

Authors: Chiang-Ho Cheng, An-Shik Yang, Chih-Jer Lin, Chun-Ying Lee

Abstract:

This paper aims to present the design, fabrication and test of a novel piezoelectric actuated, check-valves embedded micropump having the advantages of miniature size, light weight and low power consumption. This device is designed to pump gases and liquids with the capability of performing the self-priming and bubble-tolerant work mode by maximizing the stroke volume of the membrane as well as the compression ratio via minimization of the dead volume of the micropump chamber and channel. By experiment apparatus setup, we can get the real-time values of the flow rate of micropump, the displacement of the piezoelectric actuator and the deformation of the check valve, simultaneously. The micropump with check valve 0.4 mm in thickness obtained higher output performance under the sinusoidal waveform of 120 Vpp. The micropump achieved the maximum pumping rates of 42.2 ml/min and back pressure of 14.0 kPa at the corresponding frequency of 28 and 20 Hz. The presented micropump is able to pump gases with a pumping rate of 196 ml/min at operating frequencies of 280 Hz under the sinusoidal waveform of 120 Vpp.

Keywords: actuator, check-valve, micropump, piezoelectric

Procedia PDF Downloads 408
242 Endovascular Aneurysm Repair (Evar) with Endoanchors: For Tandem Aortic Abdominal Aneurysm (Aaa) with Hostile Neck & Proximal Penetrating Atherosclerotic Ulcer

Authors: Von Jerick Tenorio, Jonald Lucero, Marivic Vestal, Edwin Tiempo

Abstract:

In patients with hostile aortic neck anatomy, the risks of proximal seal complications and stent migration remain with EVAR despite improved endograft technology. This case report discusses how the technical challenges of the hostile neck anatomy, proximal penetrating atherosclerotic ulcer (PAU) and tortuous femoral access were addressed. The CT aortogram of a 63-year-old hypertensive and diabetic man with recurring abdominal discomfort revealed a fusiform infra-renal aneurysm measuring 8.8 cm in length and 5.7 cm in diameter. The proximal landing zone only has a 3 mm healthy neck with a conicity of > 10% and a thrombus of 4 mm thick. Proximal to the aneurysm is a PAU with a circumferential mural thrombus. The right femoral artery is tortuous with > 90o angulation. A 20% oversized Endurant II endograft and Aptus Heli-FX EndoAnchors were deployed as prophylaxis for type I endoleaks and endograft migration consequent to the conical neck and proximal aneurysm extension consequent to the PAU. A stiff Backup Meier guide wire facilitated the deployment of the endograft. Coil embolization of the right internal iliac artery was performed as prophylaxis for type II endoleaks. EndoAnchors can be used as an adjunct to EVAR as prophylaxis for proximal seal complications and stent migration in patients with hostile aortic aneurysm neck anatomy and concomitant proximal PAU.

Keywords: endoAnchors, endoleaks, EVAR, hostile neck

Procedia PDF Downloads 170
241 A Case of Prosthetic Vascular-Graft Infection Due to Mycobacterium fortuitum

Authors: Takaaki Nemoto

Abstract:

Case presentation: A 69-year-old Japanese man presented with a low-grade fever and fatigue that had persisted for one month. The patient had an aortic dissection on the aortic arch 13 years prior, an abdominal aortic aneurysm seven years prior, and an aortic dissection on the distal aortic arch one year prior, which were all treated with artificial blood-vessel replacement surgery. Laboratory tests revealed an inflammatory response (CRP 7.61 mg/dl), high serum creatinine (Cr 1.4 mg/dL), and elevated transaminase (AST 47 IU/L, ALT 45 IU/L). The patient was admitted to our hospital on suspicion of prosthetic vascular graft infection. Following further workups on the inflammatory response, an enhanced chest computed tomography (CT) and a non-enhanced chest DWI (MRI) were performed. The patient was diagnosed with a pulmonary fistula and a prosthetic vascular graft infection on the distal aortic arch. After admission, the patient was administered Ceftriaxion and Vancomycine for 10 days, but his fever and inflammatory response did not improve. On day 13 of hospitalization, a lung fistula repair surgery and an omental filling operation were performed, and Meropenem and Vancomycine were administered. The fever and inflammatory response continued, and therefore we took repeated blood cultures. M. fortuitum was detected in a blood culture on day 16 of hospitalization. As a result, we changed the treatment regimen to Amikacin (400 mg/day), Meropenem (2 g/day), and Cefmetazole (4 g/day), and the fever and inflammatory response began to decrease gradually. We performed a test of sensitivity for Mycobacterium fortuitum, and found that the MIC was low for fluoroquinolone antibacterial agent. The clinical course was good, and the patient was discharged after a total of 8 weeks of intravenous drug administration. At discharge, we changed the treatment regimen to Levofloxacin (500 mg/day) and Clarithromycin (800 mg/day), and prescribed these two drugs as a long life suppressive therapy. Discussion: There are few cases of prosthetic vascular graft infection caused by mycobacteria, and a standard therapy remains to be established. For prosthetic vascular graft infections, it is ideal to provide surgical and medical treatment in parallel, but in this case, surgical treatment was difficult and, therefore, a conservative treatment was chosen. We attempted to increase the treatment success rate of this refractory disease by conducting a susceptibility test for mycobacteria and treating with different combinations of antimicrobial agents, which was ultimately effective. With our treatment approach, a good clinical course was obtained and continues at the present stage. Conclusion: Although prosthetic vascular graft infection resulting from mycobacteria is a refractory infectious disease, it may be curative to administer appropriate antibiotics based on the susceptibility test in addition to surgical treatment.

Keywords: prosthetic vascular graft infection, lung fistula, Mycobacterium fortuitum, conservative treatment

Procedia PDF Downloads 129
240 A Retrospective Study of Vaginal Stenosis Following Treatment of Cervical Cancers and the Effectiveness of Rehabilitation Interventions

Authors: Manjusha R. Vagal, Shyam K. Shrivastava, Umesh Mahantshetty, Sudeep Gupta, Supriya Chopra, Reena Engineer, Amita Maheshwari, Atul Buduk

Abstract:

Vaginal stenosis is a common side effect associated with pelvic radiotherapy in cervical cancer patients which contributes negatively to woman’s health and prevents adequate vaginal/cervical examination. Vaginal dilation with a dilator is routine practice and is internationally advocated as a prophylactic measure to preserve vaginal patency. This retrospective study was carried out with the aim to know the usefulness of vaginal dilation following pelvic radiation therapy in cervical cancer patients in India. Data from medical records of 183 cervical cancer patients, which met the study criteria, were collected related to the stage of the disease, treatment received, commencement period of dilation post radiation therapy, sexual status and side effects associated to dilation practice. Data related to vaginal dimensions as per the length of insertion of a small, medium and large dilator were collected on regular follow-ups until 36 months and/or more. Vaginal dimensions as measured with the length of medium dilator insertion were used for analysis of dilation therapy results using paired t-test. Patients who underwent vaginal dilation with dilator maintained vaginal patency, also the mean vaginal length significantly increased, from 8.02 cm ± 2.69 to 9.96 ± 2.89 cm with a p value <0.001. There was no significant difference found on vaginal patency with different intervals of initiation of dilation therapy. At the third year and more following dilation therapy, significant increase in vaginal length observed with a p value of 0.0001 in both sexually active and inactive patients. Compilation of vaginal dosage during brachytherapy was inadequate, and hence, the secondary objective of the study to determine the effect of radiotherapy on the outcome of rehabilitation intervention was not studied in detail. This retrospective study has found that dilation therapy with vaginal dilators post pelvic radiotherapy is effective in preventing vaginal stenosis and improving vaginal patency and cannot be substituted with vaginal intercourse. Sexual quality of life assessment in the Indian population needs much attention.

Keywords: dilator, sexually active, vaginal dilation, vaginal stenosis

Procedia PDF Downloads 183
239 Numerical Simulation of Magnetohydrodynamic (MHD) Blood Flow in a Stenosed Artery

Authors: Sreeparna Majee, G. C. Shit

Abstract:

Unsteady blood flow has been numerically investigated through stenosed arteries to achieve an idea about the physiological blood flow pattern in diseased arteries. The blood is treated as Newtonian fluid and the arterial wall is considered to be rigid having deposition of plaque in its lumen. For direct numerical simulation, vorticity-stream function formulation has been adopted to solve the problem using implicit finite difference method by developing well known Peaceman-Rachford Alternating Direction Implicit (ADI) scheme. The effects of magnetic parameter and Reynolds number on velocity and wall shear stress are being studied and presented quantitatively over the entire arterial segment. The streamlines have been plotted to understand the flow pattern in the stenosed artery, which has significant alterations in the downstream of the stenosis in the presence of magnetic field. The results show that there are nominal changes in the flow pattern when magnetic field strength is enhanced upto 8T which can have remarkable usage to MRI machines.

Keywords: magnetohydrodynamics, blood flow, stenosis, energy dissipation

Procedia PDF Downloads 254
238 Oat βeta Glucan Attenuates the Development of Atherosclerosis and Improves the Intestinal Barrier Function by Reducing Bacterial Endotoxin Translocation in APOE-/- MICE

Authors: Dalal Alghawas, Jetty Lee, Kaisa Poutanen, Hani El-Nezami

Abstract:

Oat β-glucan a water soluble non starch linear polysaccharide has been approved as a cholesterol lowering agent by various food safety administrations and is commonly used to reduce the risk of heart disease. The molecular weight of oat β-glucan can vary depending on the extraction and fractionation methods. It is not clear whether the molecular weight has a significant impact at reducing the acceleration of atherosclerosis. The aim of this study was to investigate three different oat β-glucan fractionations on the development of atherosclerosis in vivo. With special focus on plaque stability and the intestinal barrier function. To test this, ApoE-/- female mice were fed a high fat diet supplemented with oat bran, high molecular weight (HMW) oat β-glucan fractionate and low molecular weight (LMW) oat β-glucan fractionate for 16 weeks. Atherosclerosis risk markers were measured in the plasma, heart and aortic tree. Plaque size was measured in the aortic root and aortic tree. ICAM-1, VCAM-1, E-Selectin, P-Selectin, protein levels were assessed from the aortic tree to determine plaque stability at 16 weeks. The expression of p22phox at the aortic root was evaluated to study the NADPH oxidase complex involved in nitric oxide bioavailability and vascular elasticity. The tight junction proteins E-cadherin and beta-catenin from western blot analyses were analysed as an intestinal barrier function test. Plasma LPS, intestinal D-lactate levels and hepatic FMO gene expression were carried out to confirm whether the compromised intestinal barrier lead to endotoxemia. The oat bran and HMW oat β-glucan diet groups were more effective than the LMW β-glucan diet group at reducing the plaque size and showed marked improvements in plaque stability. The intestinal barrier was compromised for all the experimental groups however the endotoxemia levels were higher in the LMW β-glucan diet group. The oat bran and HMW oat β-glucan diet groups were more effective at attenuating the development of atherosclerosis. Reasons for this could be due to the LMW oat β-glucan diet group’s low viscosity in the gut and the inability to block the reabsorption of cholesterol. Furthermore the low viscosity may allow more bacterial endotoxin translocation through the impaired intestinal barrier. In future food technologists should carefully consider how to incorporate LMW oat β-glucan as a health promoting food.

Keywords: Atherosclerosis, beta glucan, endotoxemia, intestinal barrier function

Procedia PDF Downloads 392
237 Effects of the Non-Newtonian Viscosity of Blood on Flow Field in a Constricted Artery with a Porous Plaque

Authors: Maedeh Shojaeizadeh, Amirreza Yeganegi

Abstract:

Nowadays many people lose their lives due to cardiovascular diseases. Inappropriate food habits and lack of exercise expedite deposit process of fatty substances on inner surface of blood arteries. This abnormal lump disturbs uniform blood flow and reduces oxygen delivery to active organs. This work presents a numerical simulation of Non-Newtonian blood flow in a stenosis vessel. The vessel is considered as two dimensional channel and plaque area is modelled as a homogenous porous medium. To simulate blood flow reaction around stenosis region, we use C++ code and solve coupled Cauchy, Darcy, governing continuity and energy equations. The analyses results show that viscosity power (n) plays an important role in flow separation and the size of the eddy at the downstream edge of the plaque. It is also observed that with increasing (n) value, temperature discontinuity and likelihood of vessel rupture declined.

Keywords: blood flow, computational fluid dynamic, porosity, power law fluid

Procedia PDF Downloads 437
236 Improvement of Performance of Anti-Splash Device for Cargo Oil Tank Vent Pipe Using CFD Simulation

Authors: Sung-Min Kim, Joon-Hong Park, Hyuk Choi

Abstract:

This study is focused on the comparative analysis and improvement to grasp the flow characteristic of the anti-splash device located under the P/V valve and new concept design models using the CFD. The P/V valve located upper deck to solve the pressure rising and vacuum condition of inner tank of the liquid cargo ships occurred oil outflow accident by transverse and longitudinal sloshing force. Anti-splash device is fitted to improve and prevent this problem in the shipbuilding industry, but the oil outflow accidents are still reported by ship owners. Thus, 4 types of new design model are presented by this study, and then comparative analysis is conducted with new models and existing model. Mostly the key criterion of this problem is flux in the outlet of the anti-splash device. Therefore, the flow and velocity are grasped by transient analysis, and then it decided optimum model and design parameters to develop model. Later, it is needed to develop an anti-splash device by flow test to get certification and verification using experiment equipments.

Keywords: anti-splash device, P/V valve, sloshing, CFD

Procedia PDF Downloads 605