Search results for: performance of swimming freestyle
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 12988

Search results for: performance of swimming freestyle

11128 Effect of Li-excess on Electrochemical Performance of Ni-rich LiNi₀.₉Co₀.₀₉Mn₀.₀₉O₂ Cathode Materials for Li-ion Batteries

Authors: Eyob Belew Abebe

Abstract:

Nickel-rich layered oxide cathode materials having a Ni content of ≥ 90% have great potential for use in next-generation lithium-ion batteries (LIBs), due to their high energy densities and relatively low cost. They suffer, however, from poor cycling performance and rate capability, significantly hampering their widespread applicability. In this study we synthesized a Ni-rich precursor through a co-precipitation method and added different amounts of Li-excess on the precursors using a solid-state method to obtain sintered Li1+x(Ni0.9Co0.05Mn0.05)1–xO2 (denoted as L1+x-NCM; x = 0.00, 0.02, 0.04, 0.06, and 0.08) transition metal (TM) oxide cathode materials. The L1+x-NCM cathode having a Li-excess of 4% exhibited a discharge capacity of ca. 216.17 mAh g–1 at 2.7–4.3 V, 0.1C and retained 95.7% of its initial discharge capacity (ca. 181.39 mAh g–1) after 100 cycles of 1C charge/discharge which is the best performance as compared with stoichiometric Li1+x(Ni0.9Co0.05Mn0.05)1-xO2 (i.e. x=0, Li:TM = 1:1). Furthermore, a high-rate capability of ca. 162.92 mAh g–1 at a rate of 10C, led to the 4% Li-excess optimizing the electrochemical performance, relative to the other Li-excess samples. Ex/in-situ X-ray diffraction, scanning electron microscopy, and X-ray photoelectron spectroscopy revealed that the 4% Li-excess in the Ni-rich NCM90 cathode material: (i). decreased the Li+/Ni2+ disorder by increasing the content of Ni3+ in the TM slab, (ii). increased the crystallinity, and (iii). accelerated Li+ ion transport by widening the Li-slab. Furthermore, electrochemical impedance spectroscopy and cyclic voltammetry confirmed that the appropriate Li-excess lowered the electrochemical impedance and improved the reversibility of the electrochemical reaction. Therefore, our results revealed that NCM90 cathode materials featuring an optimal Li-excess are potential candidates for use in next-generation Li-ion batteries.

Keywords: LiNi₀.₉Co₀.₀₉Mn₀.₀₉O₂, li-excess, cation mixing, structure change, cycle stability, electrochemical properties

Procedia PDF Downloads 177
11127 Service-Oriented Performance Considerations for Remotely Piloted Aircraft Systems Traffic Management

Authors: Iraj Mantegh, Charles Vidal

Abstract:

This paper considers Unmanned Aircraft Systems (UAS) Traffic Management system from a service-oriented architecture point of view and proposes a framework for its performance requirements. The architecture specifically considered is related to the Remotely Piloted Aircraft Systems (RPAS) Traffic Management that is adapted by Transport Canada, in close collaboration with other jurisdictions in the United States and European Union. First, the functional performances for each individual service that comprises the Traffic Management system are defined here, and then quantitative parameters to gauge the performances of individual services are proposed.

Keywords: UAV, drone, UAS, traffic management, UTM

Procedia PDF Downloads 178
11126 Unbreakable Obedience of Safety Regulation: The Study of Authoritarian Leadership and Safety Performance

Authors: Hong-Yi Kuo

Abstract:

Leadership is a key factor of improving workplace safety, and there have been abundant of studies which support the positive effects of appropriate leadership on employee safety performance in the western academic. However, little safety research focus on the Chinese leadership style like paternalistic leadership. To fill this gap, the resent study aims to examine the relationship between authoritarian leadership (one of the ternary mode in paternalistic leadership) and safety outcomes. This study makes hypothesis on different levels. First, on the group level, as an authoritarian leader regards safety value as the most important tasks, there would be positive effect on group safety outcomes through strengthening safety group norms by the emphasis on etiquette. Second, on the cross level, when a leader with authoritarian style has high priority on safety, employees may more obey the safety rules because of fear due to emphasis on absolute authority over the leader. Therefore, employees may show more safety performance and then increase individual safety outcomes. Survey data would be collected from 50 manufacturing groups (each group with more than 5 members and a leader) and a hierarchical linear modeling analysis would be conducted to analyze the hypothesis. Above the predictive result, the study expects to be a cornerstone of safety leadership research in the Chinese academic and practice.

Keywords: safety leadership, authoritarian leadership, group norms, safety behavior, supervisor safety priority

Procedia PDF Downloads 233
11125 Experimental Investigation of Nucleate Pool Boiling Heat Transfer on Laser-Structured Copper Surfaces of Different Patterns

Authors: Luvindran Sugumaran, Mohd Nashrul Mohd Zubir, Kazi Md Salim Newaz, Tuan Zaharinie Tuan Zahari, Suazlan Mt Aznam, Aiman Mohd Halil

Abstract:

With reference to Energy Roadmap 2050, the minimization of greenhouse gas emissions and the enhancement of energy efficiency are the two key factors that could facilitate a radical change in the world's energy infrastructure. However, the energy demands of electronic devices skyrocketed with the advent of the digital age. Currently, the two-phase cooling technique based on phase change pool boiling heat transfer has received a lot of attention because of its potential to fully utilize the latent heat of the fluid and produce a highly effective heat dissipation capacity while keeping the equipment's operating temperature within an acceptable range. There are numerous strategies available for the alteration of heating surfaces, but finding the best, simplest, and most dependable one remains a challenge. Lately, surface texturing via laser ablation has been used in a variety of investigations, demonstrating its significant potential for enhancing the pool boiling heat transfer performance. In this research, the nucleate pool boiling heat transfer performance of laser-structured copper surfaces of different patterns was investigated. The bare copper surface serves as a reference to compare the performance of laser-structured surfaces. It was observed that the heat transfer coefficients were increased with the increase of surface area ratio and the ratio of the peak-to-valley height of the microstructure. Laser machined grain structure produced extra nucleation sites, which ultimately caused the improved pool boiling performance. Due to an increase in nucleation site density and surface area, the enhanced nucleate boiling served as the primary heat transfer mechanism. The pool boiling performance of the laser-structured copper surfaces is superior to the bare copper surface in all aspects.

Keywords: heat transfer coefficient, laser structuring, micro structured surface, pool boiling

Procedia PDF Downloads 84
11124 Experimental Investigation of Nucleate Pool Boiling Heat Transfer on Laser-Structured Copper Surfaces of Different Patterns

Authors: Luvindran Sugumaran, Mohd Nashrul Mohd Zubir, Kazi Md Salim Newaz, Tuan Zaharinie Tuan Zahari, Suazlan Mt Aznam, Aiman Mohd Halil

Abstract:

With reference to Energy Roadmap 2050, the minimization of greenhouse gas emissions, and the enhancement of energy efficiency are the two key factors that could facilitate a radical change in the world's energy infrastructure. However, the energy demands of electronic devices skyrocketed with the advent of the digital age. Currently, the two-phase cooling technique based on phase change pool boiling heat transfer has received a lot of attention because of its potential to fully utilize the latent heat of the fluid and produce a highly effective heat dissipation capacity while keeping the equipment's operating temperature within an acceptable range. There are numerous strategies available for the alteration of heating surfaces, but to find the best, simplest, and most dependable one remains a challenge. Lately, surface texturing via laser ablation has been used in a variety of investigations, demonstrating its significant potential for enhancing the pool boiling heat transfer performance. In this research, the nucleate pool boiling heat transfer performance of laser-structured copper surfaces of different patterns was investigated. The bare copper surface serves as a reference to compare the performance of laser-structured surfaces. It was observed that the heat transfer coefficients were increased with the increase of surface area ratio and the ratio of the peak-to-valley height of the microstructure. Laser machined grain structure produced extra nucleation sites, which ultimately caused the improved pool boiling performance. Due to an increase in nucleation site density and surface area, the enhanced nucleate boiling served as the primary heat transfer mechanism. The pool boiling performance of the laser-structured copper surfaces is superior to the bare copper surface in all aspects.

Keywords: heat transfer coefficient, laser structuring, micro structured surface, pool boiling

Procedia PDF Downloads 82
11123 Experimental Investigation of Nucleate Pool Boiling Heat Transfer on Laser-Structured Copper Surfaces of Different Patterns

Authors: Luvindran Sugumaran, Mohd Nashrul Mohd Zubir, Kazi Md. Salim Newaz, Tuan Zaharinie Tuan Zahari, Suazlan Mt Aznam, Aiman Mohd Halil

Abstract:

With reference to Energy Roadmap 2050, the minimization of greenhouse gas emissions and the enhancement of energy efficiency are the two key factors that could facilitate a radical change in the world's energy infrastructure. However, the energy demands of electronic devices skyrocketed with the advent of the digital age. Currently, the two-phase cooling technique based on phase change pool boiling heat transfer has received a lot of attention because of its potential to fully utilize the latent heat of the fluid and produce a highly effective heat dissipation capacity while keeping the equipment's operating temperature within an acceptable range. There are numerous strategies available for the alteration of heating surfaces, but to find the best, simplest, and most dependable one remains a challenge. Lately, surface texturing via laser ablation has been used in a variety of investigations, demonstrating its significant potential for enhancing the pool boiling heat transfer performance. In this research, the nucleate pool boiling heat transfer performance of laser-structured copper surfaces of different patterns was investigated. The bare copper surface serves as a reference to compare the performance of laser-structured surfaces. It was observed that the heat transfer coefficients were increased with the increase of surface area ratio and the ratio of the peak-to-valley height of the microstructure. Laser-machined grain structure produced extra nucleation sites, which ultimately caused the improved pool boiling performance. Due to an increase in nucleation site density and surface area, the enhanced nucleate boiling served as the primary heat transfer mechanism. The pool boiling performance of the laser-structured copper surfaces is superior to the bare copper surface in all aspects.

Keywords: heat transfer coefficient, laser structuring, micro structured surface, pool boiling

Procedia PDF Downloads 85
11122 Numerical Analysis of the Turbulent Flow around DTMB 4119 Marine Propeller

Authors: K. Boumediene, S. E. Belhenniche

Abstract:

This article presents a numerical analysis of a turbulent flow past DTMB 4119 marine propeller by the means of RANS approach; the propeller designed at David Taylor Model Basin in USA. The purpose of this study is to predict the hydrodynamic performance of the marine propeller, it aims also to compare the results obtained with the experiment carried out in open water tests; a periodical computational domain was created to reduce the unstructured mesh size generated. The standard kw turbulence model for the simulation is selected; the results were in a good agreement. Therefore, the errors were estimated respectively to 1.3% and 5.9% for KT and KQ.

Keywords: propeller flow, CFD simulation, RANS, hydrodynamic performance

Procedia PDF Downloads 501
11121 Performance of Non-toxic, Corrosion Resistant, and Lubricious Metalworking Fluids under Machining

Authors: Ajay Pratap Singh Lodhi, Deepak Kumar

Abstract:

Vegetable oil-based environmentally friendly metalworking fluids (MWFs) are formulated. The tribological performance, cytotoxicity, and corrosion resistance of the formulated fluids (FFs) are evaluated and benchmarked with commercial mineral oil-based MWFs (CF). Results show that FFs exhibited better machining characteristics (roughness, cutting forces, and surface morphology) during machining than CF. MTT assay and Live dead cell assay confirm the cytocompatibility nature of the FFs relative to the toxic CF. Electrochemical analysis shows that FFs and CF exhibited comparable corrosion current density.

Keywords: corrosion inhibitors, cytotoxicity, machining, MTT assay, Taguchi method, vegetable oil

Procedia PDF Downloads 188
11120 A Hygrothermal Analysis and Structural Performance of Wood-Frame Wall Systems with Low-Permeance Exterior Insulation

Authors: Marko Spasojevic, Ying Hei Chui, Yuxiang Chen

Abstract:

Increasing the level of exterior insulation in residential buildings is a popular way for improving the thermal characteristic of building enclosure and reducing heat loss. However, the layout and properties of materials composing the wall have a great effect on moisture accumulation within the wall cavity, long-term durability of a wall as well as the structural performance. A one-dimensional hygrothermal modeling has been performed to investigate moisture condensation risks and the drying capacity of standard 2×4 and 2×6 light wood-frame wall assemblies including exterior low-permeance extruded polystyrene (XPS) insulation. The analysis considered two different wall configurations whereby the rigid insulation board was placed either between Oriented Strand Board (OSB) sheathing and the stud or outboard to the structural sheathing. The thickness of the insulation varied between 0 mm and 50 mm and the analysis has been conducted for eight different locations in Canada, covering climate zone 4 through zone 8. Results show that the wall configuration with low-permeance insulation inserted between the stud and OSB sheathing accumulates more moisture within the stud cavity, compared to the assembly with the same insulation placed exterior to the sheathing. On the other hand, OSB moisture contents of the latter configuration were markedly higher. Consequently, the analysis of hygrothermal performance investigated and compared moisture accumulation in both the OSB and stud cavity. To investigate the structural performance of the wall and the effect of soft insulation layer inserted between the sheathing and framing, forty nail connection specimens were tested. Results have shown that both the connection strength and stiffness experience a significant reduction as the insulation thickness increases. These results will be compared with results from a full-scale shear wall tests in order to investigate if the capacity of shear walls with insulated sheathing would experience a similar reduction in structural capacities.

Keywords: hygrothermal analysis, insulated sheathing, moisture performance, nail joints, wood shear wall

Procedia PDF Downloads 128
11119 The Necessity of Retrofitting for Masonry Buildings in Turkey

Authors: Soner Güler, Mustafa Gülen, Eylem Güzel

Abstract:

Masonry buildings constitute major part of building stock in Turkey. Masonry buildings were built up especially in rural areas and underdeveloped regions due to economic reasons. Almost all of these masonry buildings are not designed and detailed according to any design guidelines by designers. As a result of this, masonry buildings were totally collapsed or heavily damaged when subjected to destructive earthquake effects. Thus, these masonry buildings that were built up in our country must be retrofitted to improve their seismic performance. In this study, new seismic retrofitting techniques that is easy to apply and low-cost are summarized and the importance of seismic retrofitting is also emphasized for existing masonry buildings in Turkey.

Keywords: masonry buildings, earthquake effects, seismic retrofitting techniques, seismic performance

Procedia PDF Downloads 343
11118 Book Recommendation Using Query Expansion and Information Retrieval Methods

Authors: Ritesh Kumar, Rajendra Pamula

Abstract:

In this paper, we present our contribution for book recommendation. In our experiment, we combine the results of Sequential Dependence Model (SDM) and exploitation of book information such as reviews, tags and ratings. This social information is assigned by users. For this, we used CLEF-2016 Social Book Search Track Suggestion task. Finally, our proposed method extensively evaluated on CLEF -2015 Social Book Search datasets, and has better performance (nDCG@10) compared to other state-of-the-art systems. Recently we got the good performance in CLEF-2016.

Keywords: sequential dependence model, social information, social book search, query expansion

Procedia PDF Downloads 289
11117 New Wine in an Old Bottle? Zhong-Yong Thinking and Creativity

Authors: Li-Fang CHou, Chun-Jung Tseng, Sung-Chun Tsai

Abstract:

Zhong-Yong represents unique values and cognitive beliefs of Chinese culture. Zhong-Yong thinking emphasizes (a) holistic thinking and perspective taking, (b) tolerance of contradictions, and (c) pursuance of a person’s interpersonal and inner harmony. With a unique way of naïve dialectical thinking based on Chinese culture, previous studies have found that people with higher Zhong-Yong thinking have more cognitive resources and resilience to make decision for dilemmas and cope stresses. Creativity is defined as the behavior to create novel and value products and viewed as the most important capital for individuals and enterprises. However, the relationship between Zhong-Yong thinking and creativity is still remaining to be unexplored. Three studies were conducted to explore the effects of Zhong-Yong thinking on creativity. In Study1, with 87 undergraduate students from a university in southern Taiwan as participants, we used questionnaire to measure Zhong-Yong thinking and processed creative task (unusual uses task) to get indicators of fluency and flexibility. After controlling background and openness to experience of Big five, the results showed that Zhong-Yong thinking had significant positive effects on fluency and flexibility. In Study 2, 97 undergraduate students were recruited to do Zhong-Yong thinking task and creative task. The result showed that, compared with control group, the participants had higher creative performance after being primed with Zhong-Yong thinking. In Study 3, we adopted questionnaire survey and took 397 employees from private enterprises in Taiwan as sample. Besides the main effects of Zhong-Yong thinking, the moderating effects on the relationship between leadership behavior and employee’s creative performance were also investigated. We found that (a) Zhong-Yong thinking was positively associated to creative performance; (b) Zhong-Yong thinking strengthened the positive effects of transformational and authoritative leadership on creative performance. Finally, the implications of theory/practice and limitations/future directions were also discussed.

Keywords: Zhong-Yong thinking, creativity and creative performance, unusual uses task, transformational leadership, authoritative leadership

Procedia PDF Downloads 583
11116 Effect of Damper Combinations in Series or Parallel on Structural Response

Authors: Ajay Kumar Sinha, Sharad Singh, Anukriti Sinha

Abstract:

Passive energy dissipation method for earthquake protection of structures is undergoing developments for improved performance. Combined use of different types of damping mechanisms has shown positive results in the near past. Different supplemental damping methods like viscous damping, frictional damping and metallic damping are being combined together for optimum performance. The conventional method of connecting passive dampers to structures is a parallel connection between the damper unit and structural member. Researchers are investigating coupling effect of different types of dampers. The most popular choice among the research community is coupling of viscous dampers and frictional dampers. The series and parallel coupling of these damping units are being studied for relative performance of the coupled system on response control of structures against earthquake. In this paper an attempt has been made to couple Fluid Viscous Dampers and Frictional Dampers in series and parallel to form a single unit of damping system. The relative performance of the coupled units has been studied on three dimensional reinforced concrete framed structure. The current theories of structural dynamics in practice for viscous damping and frictional damping have been incorporated in this study. The time history analysis of the structural system with coupled damper units, uncoupled damper units as well as of structural system without any supplemental damping has been performed in this study. The investigations reported in this study show significant improved performance of coupled system. A higher natural frequency of the system outside the forcing frequency has been obtained for structural systems with coupled damper units as against the other cases. The structural response of the structure in terms of storey displacement and storey drift show significant improvement for the case with coupled damper units as against the cases with uncoupled units or without any supplemental damping. The results are promising in terms of improved response of the structure with coupled damper units. Further investigations in this regard for a comparative performance of the series and parallel coupled systems will be carried out to study the optimum behavior of these coupled systems for enhanced response control of structural systems.

Keywords: frictional damping, parallel coupling, response control, series coupling, supplemental damping, viscous damping

Procedia PDF Downloads 458
11115 The Influences of Accountants’ Potential Performance on Their Working Process: Government Savings Bank, Northeast, Thailand

Authors: Prateep Wajeetongratana

Abstract:

The purpose of this research was to study the influence of accountants’ potential performance on their working process, a case study of Government Savings Banks in the northeast of Thailand. The independent variables included accounting knowledge, accounting skill, accounting value, accounting ethics, and accounting attitude, while the dependent variable included the success of the working process. A total of 155 accountants working for Government Savings Banks were selected by random sampling. A questionnaire was used as a tool for collecting data. Descriptive statistics in this research included percentage, mean, and multiple regression analyses. The findings revealed that the majority of accountants were female with an age between 35-40 years old. Most of the respondents had an undergraduate degree with ten years of experience. Moreover, the factors of accounting knowledge, accounting skill, accounting a value and accounting ethics and accounting attitude were rated at a high level. The findings from regression analysis of observation data revealed a causal relationship in that the observation data could explain at least 51 percent of the success in the accountants’ working process.

Keywords: influence, potential performance, success, working process

Procedia PDF Downloads 229
11114 Parametric Analysis of Syn-gas Fueled SOFC with Internal Reforming

Authors: Sanjay Tushar Choudhary

Abstract:

This paper focuses on the thermodynamic analysis of Solid Oxide Fuel Cell (SOFC). In the present work the SOFC has been modeled to work with internal reforming of fuel which takes place at high temperature and direct energy conversion from chemical energy to electrical energy takes place. The fuel-cell effluent is a high-temperature steam which can be used for co-generation purposes. Syn-gas has been used here as fuel which is essentially produced by steam reforming of methane in the internal reformer of the SOFC. A thermodynamic model of SOFC has been developed for planar cell configuration to evaluate various losses in the energy conversion process within the fuel cell. Cycle parameters like fuel utilization ratio and the air-recirculation ratio have been varied to evaluate the thermodynamic performance of the fuel cell. Output performance parameters like terminal voltage, cell-efficiency and power output have been evaluated for various values of current densities. It has been observed that a combination of a lower value of air-circulation ratio and higher values of fuel utilization efficiency gives a better overall thermodynamic performance.

Keywords: current density, SOFC, suel utilization factor, recirculation ratio

Procedia PDF Downloads 508
11113 Evidence on the Impact of Corporate Governance on Bank Performance from Deposit Money Banks in Sub-Saharan Africa

Authors: Ayotunde Qudus Saka, Xin Zhang

Abstract:

Purpose: The purpose of this study is to investigate how corporate governance traits affect the financial performance of banks in the sub-Saharan African region from 2008 to 2022. Methodology/Design/Approach: The performance of a few chosen banks in Sub-Saharan Africa is examined in relation to corporate governance using static panel regression analysis. The following variables were used to present corporate governance in the study: board size (BDS), board gender diversity (BGD), board independence (BDI), number of audit committee meetings (NAM), and number of foreign members on the board (SFM). Return on assets (ROA) was employed as the dependent variable. Fixed effect (FE), random effect (RE), and common effect (CE) estimators were used with static panel data. The model estimate procedure is based on the 'Log-Lin' specification. The estimation includes eleven (11) models, ten of which relate to the individual country and one that captures the SSA countries used in this study. Finding: The RE effect estimator seems to be more efficient than the FE estimator overall. Therefore, the selected estimator used for the overall country investigation is the random effect model adopted in evaluating the connection between financial success and corporate governance, and according to the all-country specification in assessing the study's goal, the fixed effect estimator is thus selected for most of the countries except for Malawi and Zambia that common effect model worked well for showing that the banks in the aforementioned countries have similar organisational cultures and management philosophies. Consequently, the selected estimators for every country were used to evaluate the connection between financial success and corporate governance. Originality/Value: Corporate governance and bank performance topics are well grounded in literature with evidence from developed countries. However, there is a darth in developing countries particularly in the sub-Saharan African region. This study presents multi-country empirical evidence within the SSAs which gives the study more samples, this study makes use of balanced data from 2008 to 2022 being the latest data coverage from SSA, and to the best knowledge of the authors, no prior research has examined the impact of corporate governance mechanisms on bank performance in the SSA region through the use of multi-country samples.

Keywords: bank performance, corporate governance, sub-Saharan African (SSA), gender diversity, foreign member of the board, multi-country

Procedia PDF Downloads 9
11112 Long-Term Foam Roll Intervention Study of the Effects on Muscle Performance and Flexibility

Authors: T. Poppendieker

Abstract:

A new innovative tool for self-myofascial release is widely and increasingly used among athletes of various sports. The application of the foam roll is suggested to improve muscle performance and flexibility. Attempts to examine acute and somewhat long term effects of either have been conducted over the past ten years. However, the results of muscle performance have been inconsistent. It is suggested that regular use over a long period of time results in a different, muscle performance improving outcome. This study examines long-term effects of regular foam rolling combined with a short plyometric routine vs. solely the same plyometric routine on muscle performance and flexibility over a period of six weeks. Results of counter movement jump (CMJ), squat jump (SJ), and isometric maximal force (IMF) of a 90° horizontal squat in a leg-press will serve as parameters for muscle performance. Data on the range of motion (ROM) of the sit and reach test will be used as a parameter for the flexibility assessment. Muscle activation will be measured throughout all tests. Twenty male and twenty female members of a Frankfurt area fitness center chain (7.11) with an average age of 25 years will be recruited. Women and men will be randomly assigned to a foam roll (FR) and a control group. All participants will practice their assigned routine three times a week over the period of six weeks. Tests on CMJ, SJ, IMF, and ROM will be taken before and after the intervention period. The statistic software program SPSS 22 will be used to analyze the data of CMJ, SJ, IMF, and ROM under consideration of muscle activation by a 2 x 2 x 2 (time of measurement x gender x group) analysis of variance with repeated measures and dependent t-test analysis of pre- and post-test. The alpha level for statistic significance will be set at p ≤ 0.05. It is hypothesized that a significant difference in outcome based on gender differences in all four tests will be observed. It is further hypothesized that both groups may show significant improvements in their performance in the CMJ and SJ after the six-week period. However, the FR group is hypothesized to achieve a higher improvement in the two jump tests. Moreover, the FR group may increase IMF as well as flexibility, whereas the control group may not show likewise progress. The results of this study are crucial for the understanding of long-term effects of regular foam roll application. The collected information on the matter may help to motivate the incorporation of foam rolling into training routines, in order to improve athletic performances.

Keywords: counter movement jump, foam rolling, isometric maximal force, long term effects, self-myofascial release, squat jump

Procedia PDF Downloads 287
11111 Optimizing Water Consumption of a Washer-Dryer Which Contains Water Condensation Technology under a Constraint of Energy Consumption and Drying Performance

Authors: Aysegul Sarac

Abstract:

Washer-dryers are the machines which can either wash the laundries or can dry them. In other words, we can define a washer-dryer as a washing machine and a dryer in one machine. Washing machines are characterized by the loading capacity, cabinet depth and spin speed. Dryers are characterized by the drying technology. On the other hand, energy efficiency, water consumption, and noise levels are main characteristics that influence customer decisions to buy washers. Water condensation technology is the most common drying technology existing in the washer-dryer market. Water condensation technology uses water to dry the laundry inside the machine. Thus, in this type of the drying technology water consumption is at high levels comparing other technologies. Water condensation technology sprays cold water in the drum to condense the humidity of hot weather in order to dry the laundry inside. Thus, water consumption influences the drying performance. The scope of this study is to optimize water consumption during drying process under a constraint of energy consumption and drying performance. We are using 6-Sigma methodology to find the optimum water consumption by comparing drying performances of different drying algorithms.

Keywords: optimization, 6-Sigma methodology, washer-dryers, water condensation technology

Procedia PDF Downloads 362
11110 Enhancing the Dynamic Performance of Grid-Tied Inverters Using Manta Ray Foraging Algorithm

Authors: H. E. Keshta, A. A. Ali

Abstract:

Three phase grid-tied inverters are widely employed in micro-grids (MGs) as interphase between DC and AC systems. These inverters are usually controlled through standard decoupled d–q vector control strategy based on proportional integral (PI) controllers. Recently, advanced meta-heuristic optimization techniques have been used instead of deterministic methods to obtain optimum PI controller parameters. This paper provides a comparative study between the performance of the global Porcellio Scaber algorithm (GPSA) based PI controller and Manta Ray foraging optimization (MRFO) based PI controller.

Keywords: micro-grids, optimization techniques, grid-tied inverter control, PI controller

Procedia PDF Downloads 133
11109 Efficient Storage and Intelligent Retrieval of Multimedia Streams Using H. 265

Authors: S. Sarumathi, C. Deepadharani, Garimella Archana, S. Dakshayani, D. Logeshwaran, D. Jayakumar, Vijayarangan Natarajan

Abstract:

The need of the hour for the customers who use a dial-up or a low broadband connection for their internet services is to access HD video data. This can be achieved by developing a new video format using H. 265. This is the latest video codec standard developed by ISO/IEC Moving Picture Experts Group (MPEG) and ITU-T Video Coding Experts Group (VCEG) on April 2013. This new standard for video compression has the potential to deliver higher performance than the earlier standards such as H. 264/AVC. In comparison with H. 264, HEVC offers a clearer, higher quality image at half the original bitrate. At this lower bitrate, it is possible to transmit high definition videos using low bandwidth. It doubles the data compression ratio supporting 8K Ultra HD and resolutions up to 8192×4320. In the proposed model, we design a new video format which supports this H. 265 standard. The major areas of applications in the coming future would lead to enhancements in the performance level of digital television like Tata Sky and Sun Direct, BluRay Discs, Mobile Video, Video Conferencing and Internet and Live Video streaming.

Keywords: access HD video, H. 265 video standard, high performance, high quality image, low bandwidth, new video format, video streaming applications

Procedia PDF Downloads 355
11108 Performance Estimation of Two Port Multiple-Input and Multiple-Output Antenna for Wireless Local Area Network Applications

Authors: Radha Tomar, Satish K. Jain, Manish Panchal, P. S. Rathore

Abstract:

In the presented work, inset fed microstrip patch antenna (IFMPA) based two port MIMO Antenna system has been proposed, which is suitable for wireless local area network (WLAN) applications. IFMPA has been designed, optimized for 2.4 GHz and applied for MIMO formation. The optimized parameters of the proposed IFMPA have been used for fabrication of antenna and two port MIMO in a laboratory. Fabrication of the designed MIMO antenna has been done and tested experimentally for performance parameters like Envelope Correlation Coefficient (ECC), Mean Effective Gain (MEG), Directive Gain (DG), Channel Capacity Loss (CCL), Multiplexing Efficiency (ME) etc and results are compared with simulated parameters extracted with simulated S parameters to validate the results. The simulated and experimentally measured plots and numerical values of these MIMO performance parameters resembles very much with each other. This shows the success of MIMO antenna design methodology.

Keywords: multiple-input and multiple-output, wireless local area network, vector network analyzer, envelope correlation coefficient

Procedia PDF Downloads 57
11107 Performance Investigation of Thermal Insulation Materials for Walls: A Case Study in Nicosia (Turkish Republic of North Cyprus)

Authors: L. Vafaei, McDominic Eze

Abstract:

The performance of thermal energy in homes and buildings is a significant factor in terms of energy efficiency of a building. In a large sense, the performance of thermal energy is dependent on many factors of which the amount of thermal insulation is at one end a considerable factor, as likewise the essence of mass and the wall thickness and also the thermal resistance of wall material. This study is aimed at illustrating the different wall system in Turkish Republic of North Cyprus (TRNC), acknowledge the problem and suggest a solution through comparing the effect of thermal radiation two model rooms- L1 (Ytong wall) and L2 (heat insulated wall using stone wool) set up for experimentation. The model room has four face walls. The study consists of two stage, the first test is to access the effect of solar radiation for south facing wall and the second stage is to test the thermal performance of Ytong and heat insulated wall, the effects of climatic condition during winter. The heat insulated wall contains material hollow brick, stone wool, and gypsum while the Ytong wall contains cement concrete, for the outer surface and the inner surface and Ytong stone. The total heat of the wall was determined, 7T-Type thermocouple was used with a data logger system to record the data, temperature change recorded at an interval of 10 minutes. The result obtained was that Ytong wall save more energy than the heat insulated wall at night while heat insulated wall saves energy during the day when intensity is at maximum.

Keywords: heat insulation, hollow bricks, south facing, Ytong bricks wall

Procedia PDF Downloads 267
11106 Does Exercise Training Moderate the Effects of Ageing on Health

Authors: Elizabeth A. Haruna, Bulus Kpame, Kankanala Venkateswarlu

Abstract:

The interaction of health and athletic performance with biologic aging has been an interesting and intriguing area for research. There has been a general acknowledgement of its importance to major public health and elite performance outcomes. There are many questions unanswered about the mechanisms of effects and dose-response changes. An attempt has been made in this paper to highlight potentially positive effects of regular training on the aging process and its effects on health. Age associated decline in health and performance results from the combination of the aging process itself, inactive lifestyle and primary diseases. An attempt is made in this paper to critically review what is known and what is unknown about evidence based changes, common to disuse and aging. Mechanisms responsible for the slowing decline in muscle mass and muscle force (sarcopenia) down of age – associated, weakness and fatigability due to year round athletic training have been discussed. It is in this regard we have attempted to share our views on advances made so far in understanding the impact of aging on health. We also attempted to explain how the biological effects of aging are minimized during appropriate year round athletic training. On the basis of available research evidence it was concluded that exercise training significantly slow down the deleterious effects of aging on health.

Keywords: aging, atrophy, sarcopenia, plyometric training

Procedia PDF Downloads 417
11105 Mathematical Modelling of a Low Tip Speed Ratio Wind Turbine for System Design Evaluation

Authors: Amir Jalalian-Khakshour, T. N. Croft

Abstract:

Vertical Axis Wind Turbine (VAWT) systems are becoming increasingly popular as they have a number of advantages over traditional wind turbines. The advantages are reliability, ease of transportation and manufacturing. These attributes could make these technologies useful in developing economies. The performance characteristics of a VAWT are different from a horizontal axis wind turbine, which can be attributed to the low tip speed ratio operation. To unlock the potential of these VAWT systems, the operational behaviour in a number of system topologies and environmental conditions needs to be understood. In this study, a non-linear dynamic simulation method was developed in Matlab and validated against in field data of a large scale, 8-meter rotor diameter prototype. This simulation method has been utilised to determine the performance characteristics of a number of control methods and system topologies. The motivation for this research was to develop a simulation method which accurately captures the operating behaviour and is computationally inexpensive. The model was used to evaluate the performance through parametric studies and optimisation techniques. The study gave useful insights into the applications and energy generation potential of this technology.

Keywords: power generation, renewable energy, rotordynamics, wind energy

Procedia PDF Downloads 306
11104 Performance Augmentation of a Combined Cycle Power Plant with Waste Heat Recovery and Solar Energy

Authors: Mohammed A. Elhaj, Jamal S. Yassin

Abstract:

In the present time, energy crises are considered a severe problem across the world. For the protection of global environment and maintain ecological balance, energy saving is considered one of the most vital issues from the view point of fuel consumption. As the industrial sectors everywhere continue efforts to improve their energy efficiency, recovering waste heat losses provides an attractive opportunity for an emission free and less costly energy resource. In the other hand the using of solar energy has become more insistent particularly after the high gross of prices and running off the conventional energy sources. Therefore, it is essential that we should endeavor for waste heat recovery as well as solar energy by making significant and concrete efforts. For these reasons this investigation is carried out to study and analyze the performance of a power plant working by a combined cycle in which Heat Recovery System Generator (HRSG) gets its energy from the waste heat of a gas turbine unit. Evaluation of the performance of the plant is based on different thermal efficiencies of the main components in addition to the second law analysis considering the exergy destructions for the whole components. The contribution factors including the solar as well as the wasted energy are considered in the calculations. The final results have shown that there is significant exergy destruction in solar concentrator and the combustion chamber of the gas turbine unit. Other components such as compressor, gas turbine, steam turbine and heat exchangers having insignificant exergy destruction. Also, solar energy can contribute by about 27% of the input energy to the plant while the energy lost with exhaust gases can contribute by about 64% at maximum cases.

Keywords: solar energy, environment, efficiency, waste heat, steam generator, performance, exergy destruction

Procedia PDF Downloads 298
11103 Analysis of Effects of Magnetic Slot Wedges on Characteristics of Permanent Magnet Synchronous Machine

Authors: B. Ladghem Chikouche

Abstract:

The influence of slot wedges permeability on the electromagnetic performance of three-phase permanent magnet synchronous machine is investigated in this paper. It is shown that the back-EMF waveform, electromagnetic torque and electromagnetic torque ripple are all significantly affected by slot wedges permeability. The paper presents an accurate analytical subdomain model and confirmed by finite-element analyses.

Keywords: exact analytical calculation, finite-element method, magnetic field distribution, permanent magnet machines performance, stator slot wedges permeability

Procedia PDF Downloads 328
11102 Evaluation of Teaching Performance in Higher Education: From the Students' Responsibility to Their Evaluative Competence

Authors: Natacha Jesus-Silva, Carla S. Pereira, Natercia Durao, Maria Das Dores Formosinho, Cristina Costa-Lobo

Abstract:

Any assessment process, by its very nature, raises a wide range of doubts, uncertainties, and insecurities of all kinds. The evaluation process should be ethically irreproachable, treating each and every one of the evaluated according to a conduct that ensures that the process is fair, contributing to all recognize and feel well with the processes and results of the evaluation. This is a very important starting point and implies that positive and constructive conceptions and attitudes are developed regarding the evaluation of teaching performance, where students' responsibility is desired. It is not uncommon to find teachers feeling threatened at various levels, in particular as regards their autonomy and their professional dignity. Evaluation must be useful in that it should enable decisions to be taken to improve teacher performance, the quality of teaching or the learning climate of the school. This study is part of a research project whose main objective is to identify, select, evaluate and synthesize the available evidence on Quality Indicators in Higher Education. In this work, the 01 parameters resulting from pedagogical surveys in a Portuguese higher education institution in the north of the country will be presented, surveys for the 2015/2016 school year, presented to 1751 students, in a total of 11 degrees and 18 master's degrees. It has analyzed the evaluation made by students with respect to the performance of a group of 68 teachers working full time. This paper presents the lessons learned in the last three academic years, allowing for the identification of the effects on the following areas: teaching strategies and methodologies, capacity of systematization, learning climate, creation of conditions for active student participation. This paper describes the procedures resulting from the descriptive analysis (frequency analysis, descriptive measures and association measures) and inferential analysis (ANOVA one-way, MANOVA one-way, MANOVA two-way and correlation analysis).

Keywords: teaching performance, higher education, students responsibility, indicators of teaching management

Procedia PDF Downloads 278
11101 Reproductive Performance of Dairy Cows at Different Parities: A Case Study in Enrekang Regency, Indonesia

Authors: Muhammad Yusuf, Abdul Latief Toleng, Djoni Prawira Rahardja, Ambo Ako, Sahiruddin Sahiruddin, Abdi Eriansyah

Abstract:

The objective of this study was to know the reproductive performance of dairy cows at different parities. A total of 60 dairy Holstein-Friesian cows with parity one to three from five small farms raised by the farmers were used in the study. All cows were confined in tie stall barn with rubber on the concrete floor. The herds were visited twice for survey with the help of a questionnaire. Reproductive parameters used in the study were days open, calving interval, and service per conception (S/C). The results of this study showed that the mean (±SD) days open of the cows in parity 2 was slightly longer than those in parity 3 (228.2±121.5 vs. 205.5±144.5; P=0.061). None cows conceived within 85 days postpartum in parity 3 in comparison to 13.8% cows conceived in parity 2. However, total cows conceived within 150 days post partum in parity 2 and parity 3 were 30.1% and 36.4%, respectively. Likewise, after reaching 210 days after calving, number of cows conceived in parity 3 had higher than number of cows in parity 2 (72.8% vs. 44.8%; P<0.05). The mean (±SD) calving interval of the cows in parity 2 and parity 3 were 508.2±121.5 and 495.5±144.1, respectively. Number of cows with calving interval of 400 and 450 days in parity 3 was higher than those cows in parity 2 (23.1% vs. 17.2% and 53.9% vs. 31.0%). Cows in parity 1 had significantly (P<0.01) lower number of S/C in comparison to the cows with parity 2 and parity 3 (1.6±1.2 vs. 3.5±3.4 and 3.3±2.1). It can be concluded that reproductive performance of the cows is affected by different parities.

Keywords: dairy cows, parity, days open, calving interval, service per conception

Procedia PDF Downloads 258
11100 Impact of Instrument Transformer Secondary Connections on Performance of Protection System: Experiences from Indian POWERGRID

Authors: Pankaj Kumar Jha, Mahendra Singh Hada, Brijendra Singh, Sandeep Yadav

Abstract:

Protective relays are commonly connected to the secondary windings of instrument transformers, i.e., current transformers (CTs) and/or capacitive voltage transformers (CVTs). The purpose of CT and CVT is to provide galvanic isolation from high voltages and reduce primary currents and voltages to a nominal quantity recognized by the protective relays. Selecting the correct instrument transformers for an application is imperative: failing to do so may compromise the relay’s performance, as the output of the instrument transformer may no longer be an accurately scaled representation of the primary quantity. Having an accurately rated instrument transformer is of no use if these devices are not properly connected. The performance of the protective relay is reliant on its programmed settings and on the current and voltage inputs from the instrument transformers secondary. This paper will help in understanding the fundamental concepts of the connections of Instrument Transformers to the protection relays and the effect of incorrect connection on the performance of protective relays. Multiple case studies of protection system mal-operations due to incorrect connections of instrument transformers will be discussed in detail in this paper. Apart from the connection issue of instrument transformers to protective relays, this paper will also discuss the effect of multiple earthing of CTs and CVTs secondary on the performance of the protection system. Case studies presented in this paper will help the readers to analyse the problem through real-world challenges in complex power system networks. This paper will also help the protection engineer in better analysis of disturbance records. CT and CVT connection errors can lead to undesired operations of protection systems. However, many of these operations can be avoided by adhering to industry standards and implementing tried-and-true field testing and commissioning practices. Understanding the effect of missing neutral of CVT, multiple earthing of CVT secondary, and multiple grounding of CT star points on the performance of the protection system through real-world case studies will help the protection engineer in better commissioning the protection system and maintenance of the protection system.

Keywords: bus reactor, current transformer, capacitive voltage transformer, distance protection, differential protection, directional earth fault, disturbance report, instrument transformer, ICT, REF protection, shunt reactor, voltage selection relay, VT fuse failure

Procedia PDF Downloads 83
11099 Genetic Variability Studies of Some Quantitative Traits in Cowpea (Vigna unguiculata L. [Walp.] ) under Water Stress

Authors: Auwal Ibrahim Magashi, Lawan Dan Larai Fagwalawa, Muhammad Bello Ibrahim

Abstract:

A research was conducted to study genetic variability of some quantitative traits in varieties of cowpea (Vigna unguiculata L. [Walp]) under water stressed from Zaria, Nigeria. Seeds of seven varieties of cowpea (Sampea 1, Sampea 2, IAR1074, Sampea 7, Sampea 8, Sampea 10 and Sampea 12) collected from Institute for Agricultural Research (IAR), Samaru, Zaria were screened for water stressed tolerance. The seeds were then sown in poly bags containing sandy-loam arranged in Completely Randomized Design with three replications for quantitative traits evaluation. The nutritional composition of the seeds obtained from the water stress tolerant varieties of cowpea were analyzed. The result obtained revealed highly significant difference (P ≤ 0.01) in the effects of water stress on the number of wilted and dead plants at 40 days after sowing (DAS) and significant (P ≤ 0.05) 34 DAS. However, sampea 10 has the highest mean performance in terms of number of wilted plants at 34 DAS while sampea 2 and IAR 1074 has the lowest mean performance. However, sampea 7 was found to have the highest mean performance for the number of wilted plants at 40 DAS and sampea 2 is lowest. The result for quantitative traits study indicated highly significant difference (P ≤ 0.01) in the plant height, number of days to 50% flowering, number of days to maturity, number of pods per plant, pod length, number of seeds per plant and 100 seed weight; and significant (P ≤ 0.05) at seedling height and number of branches per plant. Similarly, IAR1074 was found to have high performance in terms of most of the quantitative traits under study. However, sampea 8 has the highest mean performance at nutritional level. It was therefore concluded that, all the seven cowpea genotypes were water stress tolerant and produced considerable yield that contained significant nutrients. It was recommended that IAR1074 should be grown for yield while sampea 8 should be grown for protein supplements.

Keywords: cowpea, genetic variability, quantitative traits, water stress

Procedia PDF Downloads 158