Search results for: diagnostic device
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2896

Search results for: diagnostic device

1096 Increasing the Frequency of Laser Impulses with Optical Choppers with Rotational Shafts

Authors: Virgil-Florin Duma, Dorin Demian

Abstract:

Optical choppers are among the most common optomechatronic devices, utilized in numerous applications, from radiometry to telescopes and biomedical imaging. The classical configuration has a rotational disk with windows with linear margins. This research points out the laser signals that can be obtained with these classical choppers, as well as with another, novel, patented configuration, of eclipse choppers (i.e., with rotational disks with windows with non-linear margins, oriented outwards or inwards). Approximately triangular laser signals can be obtained with eclipse choppers, in contrast to the approximately sinusoidal – with classical devices. The main topic of this work refers to another, novel device, of choppers with shafts of different shapes and with slits of various profiles (patent pending). A significant improvement which can be obtained (with regard to disk choppers) refers to the chop frequencies of the laser signals. Thus, while 1 kHz is their typical limit for disk choppers, with choppers with shafts, a more than 20 times increase in the chop frequency can be obtained with choppers with shafts. Their transmission functions are also discussed, for different types of laser beams. Acknowledgments: This research is supported by the Romanian National Authority for Scientific Research, through the project PN-III-P2-2.1-BG-2016-0297.

Keywords: laser signals, laser systems, optical choppers, optomechatronics, transfer functions, eclipse choppers, choppers with shafts

Procedia PDF Downloads 175
1095 Comparative Operating Speed and Speed Differential Day and Night Time Models for Two Lane Rural Highways

Authors: Vinayak Malaghan, Digvijay Pawar

Abstract:

Speed is the independent parameter which plays a vital role in the highway design. Design consistency of the highways is checked based on the variation in the operating speed. Often the design consistency fails to meet the driver’s expectation which results in the difference between operating and design speed. Literature reviews have shown that significant crashes take place in horizontal curves due to lack of design consistency. The paper focuses on continuous speed profile study on tangent to curve transition for both day and night daytime. Data is collected using GPS device which gives continuous speed profile and other parameters such as acceleration, deceleration were analyzed along with Tangent to Curve Transition. In this present study, models were developed to predict operating speed on tangents and horizontal curves as well as model indicating the speed reduction from tangent to curve based on continuous speed profile data. It is observed from the study that vehicle tends to decelerate from approach tangent to between beginning of the curve and midpoint of the curve and then accelerates from curve to tangent transition. The models generated were compared for both day and night and can be used in the road safety improvement by evaluating the geometric design consistency.

Keywords: operating speed, design consistency, continuous speed profile data, day and night time

Procedia PDF Downloads 144
1094 Resistance of Haemonchus spp. to Albendazole, Fenbendazole and Levamisole in 4 Goat Farms of Antioquia, Colombia

Authors: Jose D. Zapata-Torres, Esteban Naranjo-Gutiérrez, Angela M. Martínez-Valencia, Jenny J. Chaparro-Gutiérrez, David Villar-Argaiz

Abstract:

Reports of drug resistance have been made in every livestock host and to every anthelmintic class. In some regions of world, the extremely high prevalence of multi-drug resistance in nematodes of sheep and goats threatens the viability of small-ruminant industries. In the region of Antioquia, Colombia, no reports of nematode resistance have been documented due to a lack of veterinary diagnostic laboratories. The objective of this study was to evaluate the efficacy of albendazole, fenbendazole, and levamisole to control gastrointestinal nematodes in goat farms of Antioquia by doing fecal egg count reduction tests. A total of 139 crossbreed goats from four separate farms were sampled for feces prior to, and 14 days following anthelmintc treatments. Individual fecal egg counts were performed using the modified three chamber McMaster technique. The anthelmintics administered at day 0 were albendazole (farm 1, n=63), fenbendazole (farm 2, n=20), and levamisole (farm 3 and 4, n= 37, and 19). Larval cultures were used to identify the genus of nematodes using Baermann`s technique and the morphological keys for identification of L3 in small ruminants. There was no difference in fecal egg counts between 0 and 14, with means (±SD) of 1681,5 ± 2121,5 and 1715,12 ± 1895,4 epg (eggs per gram), respectively. The egg count reductions for each anthelmintic and farm were 25,86% for albendazole (farm 1), 0% for fenbendazole (farm 2), 0% (farm 3), and 5,5% (farm 4) for levamisole. The genus of nematodes identified was predominantly Haemonchus spp., with 70,27% and 82,81% for samples from day 0 and 14, respectively. These results provide evidence of a total state of resistance to 3 common anthelmintics. Further research is needed to design integrate management programs to control nematodes in small ruminants in Colombia.

Keywords: anthelmintics, goat, haemonchus, resistance

Procedia PDF Downloads 513
1093 Place of Radiotherapy in the Treatment of Intracranial Meningiomas: Experience of the Cancer Center Emir Abdelkader of Oran Algeria

Authors: Taleb L., Benarbia M., Boutira F. M., Allam H., Boukerche A.

Abstract:

Introduction and purpose of the study: Meningiomas are the most common non-glial intracranial tumors in adults, accounting for approximately 30% of all central nervous system tumors. The aim of our study is to determine the epidemiological, clinical, therapeutic, and evolutionary characteristics of a cohort of patients with intracranial meningioma treated with radiotherapy at the Emir Abdelkader Cancer Center in Oran. Material and methods: This is a retrospective study of 44 patients during the period from 2014 to 2020. The overall survival and relapse-free survival curves were calculated using the Kaplan-Meier method. Results and statistical analysis: The median age of the patients was 49 years [21-76 years] with a clear female predominance (sex ratio=2.4). The average diagnostic delay was seven months [2 to 24 months], the circumstances of the discovery of which were dominated by headaches in 54.5% of cases (n=24), visual disturbances in 40.9% (n=18), and motor disorders in 15.9% (n=7). The seat of the tumor was essentially at the level of the base of the skull in 52.3% of patients (n=23), including 29.5% (n=13) at the level of the cavernous sinus, 27.3% (n=12) at the parasagittal level and 20.5% (n=9) at the convexity. The diagnosis was confirmed surgically in 36 patients (81.8%) whose anatomopathological study returned in favor of grades I, II, and III in respectively 40.9%, 29.5%, and 11.4% of the cases. Radiotherapy was indicated postoperatively in 45.5% of patients (n=20), exclusive in 27.3% (n=12) and after tumor recurrence in 27.3% of cases (n=18). The irradiation doses delivered were as follows: 50 Gy (20.5%), 54 Gy (65.9%), and 60 Gy (13.6%). With a median follow-up of 69 months, the probabilities of relapse-free survival and overall survival at three years are 93.2% and 95.4%, respectively, whereas they are 71.2% and 80.7% at five years. Conclusion: Meningiomas are common primary brain tumors. Most often benign but can also progress aggressively. Their treatment is essentially surgical, but radiotherapy retains its place in specific situations, allowing good tumor control and overall survival.

Keywords: diagnosis, meningioma, surgery, radiotherapy, survival

Procedia PDF Downloads 84
1092 Teaching English to Rural Students: A Case Study of a Select Batch at SSN College of Engineering, Chennai

Authors: Martha Karunakar

Abstract:

There exists a wide divide between the urban and the rural students in a vast country like India. This dichotomy is seen in the resources available to them, like the learning facilities, the infra-structure, the learning ambience and meeting of their basic needs of food, clothing and shelter. This paper discusses the effect of English language teaching as a Bridge course on a select batch of rural students at an Engineering college in Chennai, one of the four Metros of India. The study aims to understand how the teacher input and the teacher- peer-student interaction facilitates the acquisition of the basic structures of the English language to a group that is minimally exposed to the language. The objective in conducting the Bridge Course is to integrate these rural students into the mainstream and empower them in terms of English speaking ability; to enable them to comprehend their respective engineering classes where the medium of instruction is English and also to be able to interact with their urban peers. This program is conducted prior to the start of a regular academic session to equip them face the rigors of engineering education. The study is placed within the framework of Interaction theory in second language acquisition. The study evaluates the impact of linking theory and practice by implementing meaningful interaction not only within classrooms but also in the common areas. By providing intensive comprehensible input, it is anticipated that participant’s level of English language improves. The teaching methods and classroom activities included individual and group participation, encompassing all the four skills of listening, speaking, reading and writing (LSRW). The diagnostic tests that were administered before the commencement of the course and the exit test after the completion were used to record the impact of the training.

Keywords: comprehensible input, interaction, rural students, teaching English

Procedia PDF Downloads 364
1091 An Assessment of the Effects of Social Conflicts on Tourism in Plateau State, Nigeria: Case Study of Jos Crisis on Hill Station Hotel

Authors: Audu Aly Fada, Adejoh Apeh Matthew

Abstract:

This research assesses the effects of social conflicts on tourism products in Plateau State. It was specifically set out to find out the major causes of social conflicts in Jos, evaluate the effects of social conflicts on the influx of tourists to Hill station hotel Jos, and the impact on revenue generation of the hotel. To achieve these objectives research questions were formulated and a sample of 30 hotel staff was selected as the respondents. Data collected were organized and analyzed using tables, percentages and mean statistics. It was found that the hospitality and tourism industry was adversely affected. The crisis brought about a decline in the number of tourist arrivals, increase in cancelled bookings, a decrease in the average length of stay of tourists and the average room occupancy. Peace is the best friend of travel and tourism, while war and insecurity are among its worst enemies. It is recommended that all stakeholders involved in tourism administration should device safer environment that supports continued patronage by providing modern security apparatus. In the same spirit, government as the main stake-holder in security provision should do more than paying lip service to guarantee security and safety of lives and properties.

Keywords: social conflict, crisis, security, tourism development

Procedia PDF Downloads 390
1090 Analysis of User Complaints and Preferences by Conducting User Surveys to Ascertain the Need for Change in Current Design of Helmets

Authors: Pratham Baheti, Rohan Sanghi, Aditya Gupta

Abstract:

In the largely populated city of New Delhi, India, there are a lot of people that travel by two-wheelers. Majority of the people wear helmets while traveling and know how important it is to wear helmets for their safety. Still, the number of deaths because of road accidents involving two-wheelers is significant. We had conducted a survey by traveling within and in the outskirts of Delhi so as to see the variation in data and in the opinion of people towards helmet being a safety device rather than to escape the traffic police. We conducted a survey at traffic junctions and crossings of all the stakeholders and collected feedback on the Helmet scenario in India. According to the survey, the possible reason for these deaths is that the people, being unaware of helmet safety standards (ISI standards for helmets), buy helmets with fake ISI mark from unauthorized helmet sellers for a cheap price. Also, for the people who do not wear a helmet at all or wear a helmet just because it is a law, the reasons that they do not want to wear a helmet is heavyweight, lack of ventilation, inconvenience due to a strap, and hair problems. To address all these problems, we are designing a helmet with reduced weight and also working on the Helmet’s retention system and ventilation. We plan to provide this product at a cheap cost whilst maintaining the ISI standards so that a larger section of the population would be able to afford the helmet.

Keywords: safety, survey, ISI marks, stakeholders, helmet

Procedia PDF Downloads 263
1089 Comparison of Deep Learning and Machine Learning Algorithms to Diagnose and Predict Breast Cancer

Authors: F. Ghazalnaz Sharifonnasabi, Iman Makhdoom

Abstract:

Breast cancer is a serious health concern that affects many people around the world. According to a study published in the Breast journal, the global burden of breast cancer is expected to increase significantly over the next few decades. The number of deaths from breast cancer has been increasing over the years, but the age-standardized mortality rate has decreased in some countries. It’s important to be aware of the risk factors for breast cancer and to get regular check- ups to catch it early if it does occur. Machin learning techniques have been used to aid in the early detection and diagnosis of breast cancer. These techniques, that have been shown to be effective in predicting and diagnosing the disease, have become a research hotspot. In this study, we consider two deep learning approaches including: Multi-Layer Perceptron (MLP), and Convolutional Neural Network (CNN). We also considered the five-machine learning algorithm titled: Decision Tree (C4.5), Naïve Bayesian (NB), Support Vector Machine (SVM), K-Nearest Neighbors (KNN) Algorithm and XGBoost (eXtreme Gradient Boosting) on the Breast Cancer Wisconsin Diagnostic dataset. We have carried out the process of evaluating and comparing classifiers involving selecting appropriate metrics to evaluate classifier performance and selecting an appropriate tool to quantify this performance. The main purpose of the study is predicting and diagnosis breast cancer, applying the mentioned algorithms and also discovering of the most effective with respect to confusion matrix, accuracy and precision. It is realized that CNN outperformed all other classifiers and achieved the highest accuracy (0.982456). The work is implemented in the Anaconda environment based on Python programing language.

Keywords: breast cancer, multi-layer perceptron, Naïve Bayesian, SVM, decision tree, convolutional neural network, XGBoost, KNN

Procedia PDF Downloads 55
1088 Modified Lot Quality Assurance Sampling (LQAS) Model for Quality Assessment of Malaria Parasite Microscopy and Rapid Diagnostic Tests in Kano, Nigeria

Authors: F. Sarkinfada, Dabo N. Tukur, Abbas A. Muaz, Adamu A. Yahuza

Abstract:

Appropriate Quality Assurance (QA) of parasite-based diagnosis of malaria to justify Artemisinin-based Combination Therapy (ACT) is essential for Malaria Programmes. In Low and Middle Income Countries (LMIC), resource constrain appears to be a major challenge in implementing the conventional QA system. We designed and implemented a modified LQAS model for QA of malaria parasite (MP) microscopy and RDT in a State Specialist Hospital (SSH) and a University Health Clinic (UHC) in Kano, Nigeria. The capacities of both facilities for MP microscopy and RDT were assessed before implementing a modified LQAS over a period of 3 months. Quality indicators comprising the qualities of blood film and staining, MP positivity rates, concordance rates, error rates (in terms of false positives and false negatives), sensitivity and specificity were monitored and evaluated. Seventy one percent (71%) of the basic requirements for malaria microscopy was available in both facilities, with the absence of certifies microscopists, SOPs and Quality Assurance mechanisms. A daily average of 16 to 32 blood samples were tested with a blood film staining quality of >70% recorded in both facilities. Using microscopy, the MP positivity rates were 50.46% and 19.44% in SSH and UHS respectively, while the MP positivity rates were 45.83% and 22.78% in SSH and UHS when RDT was used. Higher concordance rates of 88.90% and 93.98% were recorded in SSH and UHC respectively using microscopy, while lower rates of 74.07% and 80.58% in SSH and UHC were recorded when RDT was used. In both facilities, error rates were higher when RDT was used than with microscopy. Sensitivity and specificity were higher when microscopy was used (95% and 84% in SSH; 94% in UHC) than when RDT was used (72% and 76% in SSH; 78% and 81% in UHC). It could be feasible to implement an integrated QA model for MP microscopy and RDT using modified LQAS in Malaria Control Programmes in Low and Middle Income Countries that might have resource constrain for parasite-base diagnosis of malaria to justify ACT treatment.

Keywords: malaria, microscopy, quality assurance, RDT

Procedia PDF Downloads 208
1087 A Rare Case of Metastatic Basal Cell Carcinoma

Authors: Nitesh Kumar, Eoin Twohig, jasparl cheema, Sadiq mawji, Yousif al najjar

Abstract:

Basal cell carcinoma (BCC) is the commonest cutaneous malignancy affecting humans. Despite this, distant spread is exceptionally rare. Metastatic BCC (mBCC) is estimated to occur in 0.0028 - 0.5%. it aim to illustrate with the aid of histological slides, a case of mBCC occurring in a fit and well 67-year-old. Initial diagnosis of desmoplastic BCC was made in 2006 from a scalp biopsy with the lesion then being excised. Re-excision of local recurrence was undertaken the following year. In 2014 the patient presented with an ipsilateral level 2a mass. Fine Needle Aspiration raised the suspicion of metastatic carcinoma. The patient had excision of two nodes from the left neck alongside pharyngeal tonsillectomy and tongue base biopsies. Histologically, the nodes closely resembled the immunophenotype of the initial scalp lesion. The patient subsequently had a modified radical neck dissection, and residual mBCC was excised from the left Sternocleidomastoid muscle. In 2023 the patient developed haematuria. On further investigation bilateral lung lesions on CT were noted with subsequent biopsy confirming mBCC. Spinal and renal lesions have also been found. Histopathology showed clear resemblance of the lung metastases to both those in the neck and the primary (scalp BCC) – with no squamous differentiation seen. The time span from primary to occurrence of lung metastasis (18 years) affirms the indolent and slow growing nature of BCC.  This case fulfils Lattes and Kessler diagnostic criteria. High risk cases are described as those with advanced local presentation, primary tumour on the Head and Neck and locally recurrent lesions.

Keywords: BCC, metastasis, rare, skin cancer

Procedia PDF Downloads 37
1086 Changes in the Median Sacral Crest Associated with Sacrocaudal Fusion in the Greyhound

Authors: S. M. Ismail, H-H Yen, C. M. Murray, H. M. S. Davies

Abstract:

A recent study reported a 33% incidence of complete sacrocaudal fusion in greyhounds compared to a 3% incidence in other dogs. In the dog, the median sacral crest is formed by the fusion of sacral spinous processes. Separation of the 1st spinous process from the median crest of the sacrum in the dog has been reported as a diagnostic tool of type one lumbosacral transitional vertebra (LTV). LTV is a congenital spinal anomaly, which includes either sacralization of the caudal lumbar part or lumbarization of the most cranial sacral segment of the spine. In this study, the absence or reduction of fusion (presence of separation) between the 1st and 2ndspinous processes of the median sacral crest has been identified in association with sacrocaudal fusion in the greyhound, without any feature of LTV. In order to provide quantitative data on the absence or reduction of fusion in the median sacral crest between the 1st and 2nd sacral spinous processes, in association with sacrocaudal fusion. 204 dog sacrums free of any pathological changes (192 greyhound, 9 beagles and 3 labradors) were grouped based on the occurrence and types of fusion and the presence, absence, or reduction in the median sacral crest between the 1st and 2nd sacral spinous processes., Sacrums were described and classified as follows: F: Complete fusion (crest is present), N: Absence (fusion is absent), and R: Short crest (fusion reduced but not absent (reduction). The incidence of sacrocaudal fusion in the 204 sacrums: 57% of the sacrums were standard (3 vertebrae) and 43% were fused (4 vertebrae). Type of sacrum had a significant (p < .05) association with the absence and reduction of fusion between the 1st and 2nd sacral spinous processes of the median sacral crest. In the 108 greyhounds with standard sacrums (3 vertebrae) the percentages of F, N and R were 45% 23% and 23% respectively, while in the 84 fused (4 vertebrae) sacrums, the percentages of F, N and R were 3%, 87% and 10% respectively and these percentages were significantly different between standard (3 vertebrae) and fused (4 vertebrae) sacrums (p < .05). This indicates that absence of spinous process fusion in the median sacral crest was found in a large percentage of the greyhounds in this study and was found to be particularly prevalent in those with sacrocaudal fusion – therefore in this breed, at least, absence of sacral spinous process fusion may be unlikely to be associated with LTV.

Keywords: greyhound, median sacral crest, sacrocaudal fusion, sacral spinous process

Procedia PDF Downloads 431
1085 Non-Parametric Changepoint Approximation for Road Devices

Authors: Loïc Warscotte, Jehan Boreux

Abstract:

The scientific literature of changepoint detection is vast. Today, a lot of methods are available to detect abrupt changes or slight drift in a signal, based on CUSUM or EWMA charts, for example. However, these methods rely on strong assumptions, such as the stationarity of the stochastic underlying process, or even the independence and Gaussian distributed noise at each time. Recently, the breakthrough research on locally stationary processes widens the class of studied stochastic processes with almost no assumptions on the signals and the nature of the changepoint. Despite the accurate description of the mathematical aspects, this methodology quickly suffers from impractical time and space complexity concerning the signals with high-rate data collection, if the characteristics of the process are completely unknown. In this paper, we then addressed the problem of making this theory usable to our purpose, which is monitoring a high-speed weigh-in-motion system (HS-WIM) towards direct enforcement without supervision. To this end, we first compute bounded approximations of the initial detection theory. Secondly, these approximating bounds are empirically validated by generating many independent long-run stochastic processes. The abrupt changes and the drift are both tested. Finally, this relaxed methodology is tested on real signals coming from a HS-WIM device in Belgium, collected over several months.

Keywords: changepoint, weigh-in-motion, process, non-parametric

Procedia PDF Downloads 52
1084 Thick Data Techniques for Identifying Abnormality in Video Frames for Wireless Capsule Endoscopy

Authors: Jinan Fiaidhi, Sabah Mohammed, Petros Zezos

Abstract:

Capsule endoscopy (CE) is an established noninvasive diagnostic modality in investigating small bowel disease. CE has a pivotal role in assessing patients with suspected bleeding or identifying evidence of active Crohn's disease in the small bowel. However, CE produces lengthy videos with at least eighty thousand frames, with a frequency rate of 2 frames per second. Gastroenterologists cannot dedicate 8 to 15 hours to reading the CE video frames to arrive at a diagnosis. This is why the issue of analyzing CE videos based on modern artificial intelligence techniques becomes a necessity. However, machine learning, including deep learning, has failed to report robust results because of the lack of large samples to train its neural nets. In this paper, we are describing a thick data approach that learns from a few anchor images. We are using sound datasets like KVASIR and CrohnIPI to filter candidate frames that include interesting anomalies in any CE video. We are identifying candidate frames based on feature extraction to provide representative measures of the anomaly, like the size of the anomaly and the color contrast compared to the image background, and later feed these features to a decision tree that can classify the candidate frames as having a condition like the Crohn's Disease. Our thick data approach reported accuracy of detecting Crohn's Disease based on the availability of ulcer areas at the candidate frames for KVASIR was 89.9% and for the CrohnIPI was 83.3%. We are continuing our research to fine-tune our approach by adding more thick data methods for enhancing diagnosis accuracy.

Keywords: thick data analytics, capsule endoscopy, Crohn’s disease, siamese neural network, decision tree

Procedia PDF Downloads 129
1083 Hybrid Seismic Energy Dissipation Devices Made of Viscoelastic Pad and Steel Plate

Authors: Jinkoo Kim, Minsung Kim

Abstract:

This study develops a hybrid seismic energy dissipation device composed of a viscoelastic damper and a steel slit damper connected in parallel. A cyclic loading test is conducted on a test specimen to validate the seismic performance of the hybrid damper. Then a moment-framed model structure is designed without seismic load so that it is retrofitted with the hybrid dampers. The model structure is transformed into an equivalent simplified system to find out optimum story-wise damper distribution pattern using genetic algorithm. The effectiveness of the hybrid damper is investigated by fragility analysis and the life cycle cost evaluation of the structure with and without the dampers. The analysis results show that the model structure has reduced probability of reaching damage states, especially the complete damage state, after seismic retrofit. The expected damage cost and consequently the life cycle cost of the retrofitted structure turn out to be significantly small compared with those of the original structure. Acknowledgement: This research was supported by the Ministry of Trade, Industry and Energy (MOTIE) and Korea Institute for Advancement of Technology (KIAT) through the International Cooperative R & D program (N043100016).

Keywords: seismic retrofit, slit dampers, friction dampers, hybrid dampers

Procedia PDF Downloads 265
1082 Tc-99m MIBI Scintigraphy to Differentiate Malignant from Benign Lesions, Detected on Planar Bone Scan

Authors: Aniqa Jabeen

Abstract:

The aim of this study was to evaluate the effectiveness of Tc-99m MIBI (Technetium 99-methoxy-iso-butyl-isonitrile) scintigraphy to differentiate malignancies from benign lesions, which were detected on planar bone scans. Materials and Methods: 59 patients with bone lesions were enrolled in the study. The scintigraphic findings were compared with the clinical, radiological and the histological findings. Each patient initially underwent a three-phase bone scan with Tc-99m MDP (Methylene Diphosphonate) and if evidence of lesion found, the patient then underwent a dynamic and static MIBI scintigraphy after three to four days. The MDP and MIBI scans were evaluated visually and quantitatively. For quantitative analysis count ratios of lesions and contralateral normal side (L/C) were taken by region of interests drawn on scans. The Student T test was applied to assess the significant difference between benign and malignant lesions p-value < 0.05 was considered significant. Result: The MDP scans showed the increase tracer uptake, but there was no significant difference between benign and malignant uptake of the radiotracer. However significant difference (p-value 0.015), in uptake was seen in malignant (L/C = 3.51 ± 1.02) and benign lesion (L/C = 2.50±0.42) on MIBI scan. Three of thirty benign lesions did not show significant MIBI uptake. Seven malignant appeared as false negatives. Specificity of the scan was 86.66%, and its Negative Predictive Value (NPV) was 81.25% whereas the sensitivity of scan was 79.31%. In excluding the axial metastasis from the lesions, the sensitivity of MIBI scan increased to 91.66% and the NPV also increased to 92.85%. Conclusion: MIBI scintigraphy provides its usefulness by distinguishing malignant from benign lesions. MIBI also correctly identifies metastatic lesions. The negative predictive value of the scan points towards its ability to accurately diagnose the normal (benign) cases. However, biopsy remains the gold standard and a definitive diagnostic modality in musculoskeletal tumors. MIBI scan provides useful information in preoperative assessment and in distinguishing between malignant and benign lesions.

Keywords: benign, malignancies, MDP bone scan, MIBI scintigraphy

Procedia PDF Downloads 383
1081 Modification of a Human Powered Lawn Mower

Authors: Akinwale S. O., Koya O. A.

Abstract:

The need to provide ecologically-friendly and effective lawn mowing solution is crucial for the well-being of humans. This study involved the modification of a human-powered lawn mower designed to cut tall grasses in residential areas. This study designed and fabricated a reel-type mower blade system and a pedal-powered test rig for the blade system. It also evaluated the performance of the machine. The machine was tested on some overgrown grass plots at College of Education Staff School Ilesa. Parameters such as theoretical field capacity, field efficiency and effective field capacity were determined from the data gathered. The quality of cut achieved by the unit was also documented. Test results showed that the fabricated cutting system produced a theoretical field capacity of 0.11 ha/h and an effective field capacity of 0.08ha/h. Moreover, the unit’s cutting system showed a substantial improvement over existing reel mower designs in its ability to cut on both the forward and reverse phases of its motion. This study established that the blade system described herein has the capacity to cut tall grasses. Hence, this device can therefore eliminate the need for powered mowers entirely on small residential lawns.

Keywords: effective field capacity, field efficiency, theoretical field capacity, quality of cut

Procedia PDF Downloads 129
1080 Internet of Things Based Patient Health Monitoring System

Authors: G. Yoga Sairam Teja, K. Harsha Vardhan, A. Vinay Kumar, K. Nithish Kumar, Ch. Shanthi Priyag

Abstract:

The emergence of the Internet of Things (IoT) has facilitated better device control and monitoring in the modern world. The constant monitoring of a patient would be drastically altered by the usage of IoT in healthcare. As we've seen in the case of the COVID-19 pandemic, it's important to keep oneself untouched while continuously checking on the patient's heart rate and temperature. Additionally, patients with paralysis should be closely watched, especially if they are elderly and in need of special care. Our "IoT BASED PATIENT HEALTH MONITORING SYSTEM" project uses IoT to track patient health conditions in an effort to address these issues. In this project, the main board is an 8051 microcontroller that connects a number of sensors, including a heart rate sensor, a temperature sensor (LM-35), and a saline water measuring circuit. These sensors are connected via an ESP832 (WiFi) module, which enables the sending of recorded data directly to the cloud so that the patient's health status can be regularly monitored. An LCD is used to monitor the data in offline mode, and a buzzer will sound if any variation from the regular readings occurs. The data in the cloud may be viewed as a graph, making it simple for a user to spot any unusual conditions.

Keywords: IoT, ESP8266, 8051 microcontrollers, sensors

Procedia PDF Downloads 69
1079 Discrimination and Classification of Vestibular Neuritis Using Combined Fisher and Support Vector Machine Model

Authors: Amine Ben Slama, Aymen Mouelhi, Sondes Manoubi, Chiraz Mbarek, Hedi Trabelsi, Mounir Sayadi, Farhat Fnaiech

Abstract:

Vertigo is a sensation of feeling off balance; the cause of this symptom is very difficult to interpret and needs a complementary exam. Generally, vertigo is caused by an ear problem. Some of the most common causes include: benign paroxysmal positional vertigo (BPPV), Meniere's disease and vestibular neuritis (VN). In clinical practice, different tests of videonystagmographic (VNG) technique are used to detect the presence of vestibular neuritis (VN). The topographical diagnosis of this disease presents a large diversity in its characteristics that confirm a mixture of problems for usual etiological analysis methods. In this study, a vestibular neuritis analysis method is proposed with videonystagmography (VNG) applications using an estimation of pupil movements in the case of an uncontrolled motion to obtain an efficient and reliable diagnosis results. First, an estimation of the pupil displacement vectors using with Hough Transform (HT) is performed to approximate the location of pupil region. Then, temporal and frequency features are computed from the rotation angle variation of the pupil motion. Finally, optimized features are selected using Fisher criterion evaluation for discrimination and classification of the VN disease.Experimental results are analyzed using two categories: normal and pathologic. By classifying the reduced features using the Support Vector Machine (SVM), 94% is achieved as classification accuracy. Compared to recent studies, the proposed expert system is extremely helpful and highly effective to resolve the problem of VNG analysis and provide an accurate diagnostic for medical devices.

Keywords: nystagmus, vestibular neuritis, videonystagmographic system, VNG, Fisher criterion, support vector machine, SVM

Procedia PDF Downloads 125
1078 The Antecedent Variables of Government Financial Accounting System (SAKD) Implementation and Its Consequences: Empirical Study on the Device of Regional Coordinating Agency for Development of Cross County, City Region III Central Java Province, Indo

Authors: Dona Primasari

Abstract:

This study examines the antecedent variables of Government Financial Acccounting System (SAKD) implementation and its consequence. The antecedent variables are: decentralization of decision making, adaptation, and the manager support. The consequences are satisfaction and performance officer. This research represents the empirical test which used convenience sampling technics in data collection. The data were collected from 167 officers of local government in the Regional Coordinating Agency for Development of Cross County/City Region III Central Java Province. Data analysis used Structural Equation Model (SEM) with the AMOS 18.0 program. The result of hypothesis examination indicates that six raised hypothesis are accepted and two hypothesis are rejected.

Keywords: decentralization of decision making, adaptation officer, manager support, implementation of Government Accounting Financial System (SAKD), satisfaction and performance officer

Procedia PDF Downloads 375
1077 PDMS-Free Microfluidic Chips Fabrication and Utilisation for Pulsed Electric Fields Applications

Authors: Arunas Stirke, Neringa Bakute, Gatis Mozolevskis

Abstract:

A technology of microfluidics is an emerging tool in the field of biology, medicine and chemistry. Microfluidic device is also known as ‘lab-on-a-chip’ technology [1]. In moving from macro- to microscale, there is unprecedented control over spatial and temporal gradients and patterns that cannot be captured in conventional Petri dishes and well plates [2]. However, there is not a single standard microfluidic chip designated for all purposes – every different field of studies needs a specific microchip with certain geometries, inlet/outlet, channel depth and other parameters to precisely regulate the required function. Since our group is studying an effect of pulsed electric field (PEF) to the cells, we have manufactured a microfluidic chip designated for high-throughput electroporation of cells. In our microchip, a cell culture chamber is divided into two parallel channels by a membrane, meanwhile electrodes for electroporation are attached to the wall of the channels. Both microchannels have their own inlet and outlet, enabling injection of transfection material separately. Our perspective is to perform electroporation of mammalian cells in two different ways: (1) plasmid and cells are injected in the same microchannel and (2) injected into separate microchannels. Moreover, oxygen and pH sensors are integrated on order to analyse cell viability parameters after PEF treatment.

Keywords: microfluidics, chip, fabrication, electroporation

Procedia PDF Downloads 64
1076 Psychological Alarm among Individuals Suffering from Irritable Bowel Syndrome

Authors: Selim A., Albasher N., Bakrmom G., Alanzi S.

Abstract:

Irritable bowel syndrome (IBS) is a chronic functional bowel disorder characterized by abdominal discomfort or pain and associated with alteration in frequency and/or form of bowel habit among other symptoms. This diagnosis is associated with increased levels of psychological distress, maladaptive coping, genetic risk factors, abnormal small and colonic intestine transit, change in stool frequency or form and abdominal discomfort or pain. Aim: The aim of the study was to assess psychological alarm among individuals suffering from Irritable Bowel Syndrome (IBS). Methods: A cross-sectional correlational research design was used to conduct the current study. A convenience sample of 504 participants was included in the present study. Data were collected using a self-report questionnaire. The questionnaire included socio-demographic data, ROME III to identify Irritable Bowel Syndrome (IBS) and Psychological Alarm Questionnaire. Results: Out of 504 participants who reported abdominal discomfort, 297 (58.9 %) participants met the diagnostic criteria of IBS. The mean age of the IBS participants was 30.16 years, females composed 75.1% of the IBS participants, and 55.2% did not seek medical help. Psychological alarms such as feeling anxious, feeling depressed, having suicidal ideations, bodily pain, having impaired functioning due to pain and feeling unable to cope with pain were significantly high among IBS individuals when compared to individuals not suffering from IBS. Psychological alarms such as feeling anxious, feeling depressed, having suicidal ideations, bodily pain, having impaired functioning due to pain and feeling unable to cope with pain were significantly high among IBS individuals compared to individuals not suffering from IBS. Conclusion: IBS is highly associated with significant psychological alarms including depression, anxiety and suicidal ideas.

Keywords: abdominal pain , irritable bowel syndrome, distress, psychological alarms

Procedia PDF Downloads 169
1075 Analysing Maximum Power Point Tracking in a Stand Alone Photovoltaic System

Authors: Osamede Asowata

Abstract:

Optimized gain in respect to output power of stand-alone photovoltaic (PV) systems is one of the major focus of PV in recent times. This is evident in its low carbon emission and efficiency. Power failure or outage from commercial providers, in general, does not promote development to public and private sector; these basically limit the development of industries. The need for a well-structured PV system is of importance for an efficient and cost effective monitoring system. The purpose of this paper is to validate the maximum power point of an off-grid PV system taking into consideration the most effective tilt and orientation angles for PV's in the southern hemisphere. This paper is based on analyzing the system using a solar charger with maximum power point tracking (MPPT) from a pulse width modulation (PWM) perspective. The power conditioning device chosen is a solar charger with MPPT. The practical setup consists of a PV panel that is set to an orientation angle of 0°N, with a corresponding tilt angle of 36°, 26°, and 16°. Preliminary results include regression analysis (normal probability plot) showing the maximum power point in the system as well the best tilt angle for maximum power point tracking.

Keywords: poly-crystalline PV panels, solar chargers, tilt and orientation angles, maximum power point tracking, MPPT, Pulse Width Modulation (PWM).

Procedia PDF Downloads 155
1074 Web Quest as the Tool for Business Writing Skills Enhancement at Technical University EFL Classes

Authors: Nadezda Kobzeva

Abstract:

Under the current trend of globalization, economic and technological dynamics information and the means by which it is delivered and renewed becomes out-of-date rapidly. Thus, educational systems as well as higher education are being seriously tested. New strategies’ developing that is supported by Information and Communication Technology is urgently required. The essential educators’ mission is to meet the demands of the future by preparing our young learners with proper knowledge, skills and innovation capabilities necessary to advance our competitiveness globally. In response to the modern society and future demands, the oldest Siberian Tomsk Polytechnic University has wisely proposed several initiatives to promote the integration of Information and Communication Technology (ICT) in education, and increase the competitiveness of graduates by emphasizing inquiry-based learning, higher order thinking and problem solving. This paper gives a brief overview of how Web Quest as ICT device is being used for language teaching and describes its use advantages for teaching English as a Foreign Language (EFL), in particular business writing skills. This study proposes to use Web Quest to promote higher order thinking and ICT integration in the process of engineers training in Tomsk Polytechnic University, Russia.

Keywords: web quest, web quest in pedagogy, resume (CVs) and cover letter writing skills, ICT integration

Procedia PDF Downloads 358
1073 p210 BCR-ABL1 CML with CMML Clones: A Rare Presentation

Authors: Mona Vijayaran, Gurleen Oberoi, Sanjay Mishra

Abstract:

Introduction: p190 BCR‐ABL1 in CML is often associated with monocytosis. In the case described here, monocytosis is associated with coexisting p210 BCR‐ABL and CMML clones. Mutation analysis using next‐generation sequence (NGS) in our case showed TET2 and SRSF2 mutations. Aims & Objectives: A 75-year male was evaluated for monocytosis and thrombocytopenia. CBC showed Hb-11.8g/dl, TLC-12,060/cmm, Monocytes-35%, Platelets-39,000/cmm. Materials & Methods: Bone marrow examination showed a hypercellular marrow with myeloid series showing sequential maturation up to neutrophils with 30% monocytes. Immunophenotyping by flow cytometry from bone marrow had 3% blasts. Making chronic myelomonocytic leukemia as the likely diagnosis. NGS for myeloid mutation panel had TET2 (48.9%) and SRSF2 (32.5%) mutations. This report further supported the diagnosis of CMML. To fulfil the WHO diagnostic criteria for CMML, a BCR ABL1 by RQ-PCR was sent. The report came positive for p210 (B3A2, B2A2) Major Transcript (M-BCR) % IS of 38.418. Result: The patient was counselled regarding the unique presentation of the presence of 2 clones- P210 CML and CMML. After discussion with an international faculty with vast experience in CMML. It was decided to start this elderly gentleman on Imatinib 200mg and not on azacytidine, as ASXL1 was not present; hence, his chances of progressing to AML would be less and on the other end, if CML is left untreated then chances of progression to blast phase would always be a possibility. After 3 months on Imatinib his platelet count improved to 80,000 to 90,000/cmm, but his monocytosis persists. His 3rd month BCR-ABL1 IS% is 0.004%. Conclusion: After searching the literature, there were no case reports of a coexisting CML p210 with CMML. This case might be the first case report. p190 BCR ABL1 is often associated with monocytosis. There are few case reports of p210 BCR ABL1 positivity in patients with monocytosis but none with coexisting CMML. This case highlights the need for extensively evaluating patients with monocytosis with next-generation sequencing for myeloid mutation panel and BCR-ABL1 by RT-PCR to correctly diagnose and treat them.

Keywords: CMML, NGS, p190 CML, Imatinib

Procedia PDF Downloads 62
1072 The Structural and Electrical Properties of Cadmium Implanted Silicon Diodes at Room Temperature

Authors: J. O. Bodunrin, S. J. Moloi

Abstract:

This study reports on the x-ray crystallography (XRD) structure of cadmium-implanted p-type silicon, the current-voltage (I-V) and capacitance-voltage (C-V) characteristics of unimplanted and cadmium-implanted silicon-based diodes. Cadmium was implanted at the energy of 160 KeV to the fluence of 10¹⁵ ion/cm². The results obtained indicate that the diodes were well fabricated, and the introduction of cadmium results in a change in behavior of the diodes from normal exponential to ohmic I-V behavior. The C-V measurements, on the other hand, show that the measured capacitance increased after cadmium doping due to the injected charge carriers. The doping density of the p-Si material and the device's Schottky barrier height was extracted, and the doping density of the undoped p-Si material increased after cadmium doping while the Schottky barrier height reduced. In general, the results obtained here are similar to those obtained on the diodes fabricated on radiation-hard material, indicating that cadmium is a promising metal dopant to improve the radiation hardness of silicon. Thus, this study would assist in adding possible options to improve the radiation hardness of silicon to be used in high energy physics experiments.

Keywords: cadmium, capacitance-voltage, current-voltage, high energy physics experiment, x-ray crystallography, XRD

Procedia PDF Downloads 118
1071 Control of an Asymmetrical Design of a Pneumatically Actuated Ambidextrous Robot Hand

Authors: Emre Akyürek, Anthony Huynh, Tatiana Kalganova

Abstract:

The Ambidextrous Robot Hand is a robotic device with the purpose to mimic either the gestures of a right or a left hand. The symmetrical behavior of its fingers allows them to bend in one way or another keeping a compliant and anthropomorphic shape. However, in addition to gestures they can reproduce on both sides, an asymmetrical mechanical design with a three tendons routing has been engineered to reduce the number of actuators. As a consequence, control algorithms must be adapted to drive efficiently the ambidextrous fingers from one position to another and to include grasping features. These movements are controlled by pneumatic muscles, which are nonlinear actuators. As their elasticity constantly varies when they are under actuation, the length of pneumatic muscles and the force they provide may differ for a same value of pressurized air. The control algorithms introduced in this paper take both the fingers asymmetrical design and the pneumatic muscles nonlinearity into account to permit an accurate control of the Ambidextrous Robot Hand. The finger motion is achieved by combining a classic PID controller with a phase plane switching control that turns the gain constants into dynamic values. The grasping ability is made possible because of a sliding mode control that makes the fingers adapt to the shape of an object before strengthening their positions.

Keywords: ambidextrous hand, intelligent algorithms, nonlinear actuators, pneumatic muscles, robotics, sliding control

Procedia PDF Downloads 276
1070 Demographic Characteristics and Factors Affecting Mortality in Pediatric Trauma Patients Who Are Admitted to Emergency Service

Authors: Latif Duran, Erdem Aydin, Ahmet Baydin, Ali Kemal Erenler, Iskender Aksoy

Abstract:

Aim: In this retrospective study, we aim to contribute to the literature by presenting the proposals for taking measures to reduce the mortality by examining the demographic characteristics of the pediatric age group patients presenting with trauma and the factors that may cause mortality Material and Method: This study has been performed by retrospectively investigating the data obtained from the patient files and the hospital automation registration system of the pediatric trauma patients who applied to the Adult Emergency Department of the Ondokuz Mayıs University Medical Faculty between January 1, 2016, and December 31, 2016. Results: 289 of 415 patients involved in our study, were males. The median age was 11.3 years. The most common trauma mechanism was falling from the high. A significant statistical difference was found on the association between trauma mechanisms and gender. An increase in the number of trauma cases was found especially in the summer months. The study showed that thoracic and abdominal trauma was relevant to the increased mortality. Computerized tomography was the most common diagnostic imaging modality. The presence of subarachnoid hemorrhage has increased the risk of mortality by 62.3 fold. Eight of the patients (1.9%) died. Scoring systems were statistically significant to predict mortality. Conclusion: Children are vulnerable to trauma because of their unique anatomical and physiological differences compared to adult patient groups. It will be more successful in the mortality rate and in the post-traumatic healing process by administering the patient triage fast and most appropriate trauma centers in the prehospital period, management of the critical patients with the scoring systems and management with standard treatment protocols

Keywords: emergency service, pediatric patients, scoring systems, trauma, age groups

Procedia PDF Downloads 185
1069 Lab Bench for Synthetic Aperture Radar Imaging System

Authors: Karthiyayini Nagarajan, P. V. Ramakrishna

Abstract:

Radar Imaging techniques provides extensive applications in the field of remote sensing, majorly Synthetic Aperture Radar (SAR) that provide high resolution target images. This paper work puts forward the effective and realizable signal generation and processing for SAR images. The major units in the system include camera, signal generation unit, signal processing unit and display screen. The real radio channel is replaced by its mathematical model based on optical image to calculate a reflected signal model in real time. Signal generation realizes the algorithm and forms the radar reflection model. Signal processing unit provides range and azimuth resolution through matched filtering and spectrum analysis procedure to form radar image on the display screen. The restored image has the same quality as that of the optical image. This SAR imaging system has been designed and implemented using MATLAB and Quartus II tools on Stratix III device as a System (Lab Bench) that works in real time to study/investigate on radar imaging rudiments and signal processing scheme for educational and research purposes.

Keywords: synthetic aperture radar, radio reflection model, lab bench, imaging engineering

Procedia PDF Downloads 476
1068 Reliability Analysis of a Life Support System in a Public Aquarium

Authors: Mehmet Savsar

Abstract:

Complex Life Support Systems (LSS) are used in all large commercial and public aquariums in order to keep the fish alive. Reliabilities of individual equipment, as well as the complete system, are extremely important and critical since the life and safety of important fish depend on these life support systems. Failure of some critical device or equipment, which do not have redundancy, results in negative consequences and affects life support as a whole. In this paper, we have considered a life support system in a large public aquarium in Kuwait Scientific Center and presented a procedure and analysis to show how the reliability of such systems can be estimated by using appropriate tools and collected data. We have also proposed possible improvements for systems reliability. In particular, addition of parallel components and spare parts are considered and the numbers of spare parts needed for each component to achieve a required reliability during specified lead time are calculated. The results show that significant improvements in system reliability can be achieved by operating some LSS components in parallel and having certain numbers of spares available in the spare parts inventories. The procedures and the results presented in this paper are expected to be useful for aquarium engineers and maintenance managers dealing with LSS.

Keywords: life support systems, aquariums, reliability, failures, availability, spare parts

Procedia PDF Downloads 267
1067 Excitation Density and Energy Dependent Relaxation Dynamics of Charge Carriers in Large Area 2D TMDCs

Authors: Ashish Soni, Suman Kalyan Pal

Abstract:

Transition metal dichalcogenides (TMDCs) are an emerging paradigm for the generation of advanced materials which are capable of utilizing in future device applications. In recent years TMDCs have attracted researchers for their unique band structure in monolayers. Large-area monolayers could become the most appropriate candidate for flexible and thin optoelectronic devices. For this purpose, it is crucial to understand the generation and transport of charge carriers in low dimensions. A deep understanding of photo-generated hot charges and trapped charges is essential to improve the performance of optoelectronic devices. Carrier trapping by the defect states that are introduced during the growth process of the monolayer could influence the dynamical behaviour of charge carriers. Herein, we investigated some aspects of the ultrafast evolution of the initially generated hot carriers and trapped charges in large-area monolayer WS₂ by measuring transient absorption at energies above and below the band gap energy. Our excitation density and energy-dependent measurements reveal the trapping of the initially generated charge carrier. Our results could be beneficial for the development of TMDC-based optoelectronic devices.

Keywords: transient absorption, optoelectronics, 2D materials, TMDCs, exciton

Procedia PDF Downloads 54