Search results for: intra arricular distal humerus fracture
1138 An Experimental Investigation on Mechanical Behaviour of Fiber Reinforced Polymer (FRP) Composite Laminates Used for Pipe Applications
Authors: Tasnim Kallel, Rim Taktak
Abstract:
In this experimental work, fiber reinforced polymer (FRP) composite laminates were manufactured using hand lay-up technique. The unsaturated polyester (UP) and vinylester (VE) were considered as resins reinforced with different woven fabrics (bidirectional and quadriaxial rovings). The mechanical behaviour of the resulting composites was studied and then compared. A focus was essentially done on the evaluation of the effect of E-Glass fiber and ply orientation on the mechanical properties such as tensile strength, flexural strength, and hardness of the studied composite laminates. Also, crack paths and fracture surfaces were examined, and failure mechanisms were analyzed. From the main results, it was found that the quadriaxial composite laminates (QA/VE and QA/UP) with stacking sequences of [0°, +45°, 90°, -45°] present a very ductile tensile behaviour. The other laminate samples (R500/VE, RM/VE, R500/UP and RM/UP) show a very brittle behaviour whatever the used resin. The intrinsic toughness KIC of QA/VE laminate, obtained in fracture tests, are found more important than that of RM/VE composite. Thus, the QA/VE samples, as multidirectional laminate, presents the highest interlaminar fracture resistance.Keywords: crack growth, fiber orientation, fracture behavior, e-glass fiber fabric, laminate composite, mechanical behavior
Procedia PDF Downloads 2501137 Coupled Hydro-Geomechanical Modeling of Oil Reservoir Considering Non-Newtonian Fluid through a Fracture
Authors: Juan Huang, Hugo Ninanya
Abstract:
Oil has been used as a source of energy and supply to make materials, such as asphalt or rubber for many years. This is the reason why new technologies have been implemented through time. However, research still needs to continue increasing due to new challenges engineers face every day, just like unconventional reservoirs. Various numerical methodologies have been applied in petroleum engineering as tools in order to optimize the production of reservoirs before drilling a wellbore, although not all of these have the same efficiency when talking about studying fracture propagation. Analytical methods like those based on linear elastic fractures mechanics fail to give a reasonable prediction when simulating fracture propagation in ductile materials whereas numerical methods based on the cohesive zone method (CZM) allow to represent the elastoplastic behavior in a reservoir based on a constitutive model; therefore, predictions in terms of displacements and pressure will be more reliable. In this work, a hydro-geomechanical coupled model of horizontal wells in fractured rock was developed using ABAQUS; both extended element method and cohesive elements were used to represent predefined fractures in a model (2-D). A power law for representing the rheological behavior of fluid (shear-thinning, power index <1) through fractures and leak-off rate permeating to the matrix was considered. Results have been showed in terms of aperture and length of the fracture, pressure within fracture and fluid loss. It was showed a high infiltration rate to the matrix as power index decreases. A sensitivity analysis is conclusively performed to identify the most influential factor of fluid loss.Keywords: fracture, hydro-geomechanical model, non-Newtonian fluid, numerical analysis, sensitivity analysis
Procedia PDF Downloads 2061136 Expression of PGC-1 Alpha Isoforms in Response to Eccentric and Concentric Resistance Training in Healthy Subjects
Authors: Pejman Taghibeikzadehbadr
Abstract:
Background and Aim: PGC-1 alpha is a transcription factor that was first detected in brown adipose tissue. Since its discovery, PGC-1 alpha has been known to facilitate beneficial adaptations such as mitochondrial biogenesis and increased angiogenesis in skeletal muscle following aerobic exercise. Therefore, the purpose of this study was to investigate the expression of PGC-1 alpha isoforms in response to eccentric and concentric resistance training in healthy subjects. Materials and Methods: Ten healthy men were randomly divided into two groups (5 patients in eccentric group - 5 in eccentric group). Isokinetic contraction protocols included eccentric and concentric knee extension with maximum power and angular velocity of 60 degrees per second. The torques assigned to each subject were considered to match the workload in both protocols, with a rotational speed of 60 degrees per second. Contractions consisted of a maximum of 12 sets of 10 repetitions for the right leg, a rest time of 30 seconds between each set. At the beginning and end of the study, biopsy of the lateral broad muscle tissue was performed. Biopsies were performed in both distal and proximal directions of the lateral flank. To evaluate the expression of PGC1α-1 and PGC1α-4 genes, tissue analysis was performed in each group using Real-Time PCR technique. Data were analyzed using dependent t-test and covariance test. SPSS21 software and Exell 2013 software were used for data analysis. Results: The results showed that intra-group changes of PGC1α-1 after one session of activity were not significant in eccentric (p = 0.168) and concentric (p = 0.959) groups. Also, inter-group changes showed no difference between the two groups (p = 0.681). Also, intra-group changes of PGC1α-4 after one session of activity were significant in an eccentric group (p = 0.012) and concentric group (p = 0.02). Also, inter-group changes showed no difference between the two groups (p = 0.362). Conclusion: It seems that the lack of significant changes in the desired variables due to the lack of exercise pressure is sufficient to stimulate the increase of PGC1α-1 and PGC1α-4. And with regard to reviewing the answer, it seems that the compatibility debate has different results that need to be addressed.Keywords: eccentric contraction, concentric contraction, PGC1α-1 و PGC1α-4, human subject
Procedia PDF Downloads 781135 The Multiaxial Load Proportionality Effect on the Fracture Surface Topography of Forged Magnesium Alloys
Authors: Andrew Gryguć, Seyed Behzad Behravesh, Hamid Jahed, Mary Wells, Wojciech Macek, Bruce Williams
Abstract:
This extended abstract investigates the influence of the multiaxial loading on the fatigue behavior of forged magnesium through quantitative analysis of its fracture surface topography and mesoscopic cracking orientation. Fatigue tests were performed on hollow tubular sample geometries extracted from closed-die forged AZ80 Mg components, with three different multiaxial strain paths (axial/shear), proportional, 45° out of phase, and 90° out of phase. Regardless of the strain path, fatigue cracks are initiated at the outer surface of the specimen where the combined stress state is largest. Depending on the salient mode of deformation, distinctive features in the fracture surface manifested themselves with different topographic amplitudes, surface roughness, and mesoscopic cracking orientation in the vicinity of the initiation site. The dominant crack propagation path was in the circumferential direction of the hollow tubular specimen (i.e., cracking transverse to the sample axis, with little to no branching), which is congruent with previous findings of low to moderate shear strain energy density (SED) multiaxial loading. For proportional loading, the initiation zone surface morphology was largely flat and striated, whereas, at phase angles of 45° and 90°, the initiation surface became more faceted and inclined. Overall, both a qualitative and quantitative link was developed between the fracture surface morphology and the level of non-proportionality in the loading providing useful insight into the fracture mechanics of forged magnesium as a relevant focus for future study.Keywords: fatigue, fracture, magnesium, forging, fractography, anisotropy, strain energy density, asymmetry, multiaxial fatigue
Procedia PDF Downloads 821134 Simulation of Hydraulic Fracturing Fluid Cleanup for Partially Degraded Fracturing Fluids in Unconventional Gas Reservoirs
Authors: Regina A. Tayong, Reza Barati
Abstract:
A stable, fast and robust three-phase, 2D IMPES simulator has been developed for assessing the influence of; breaker concentration on yield stress of filter cake and broken gel viscosity, varying polymer concentration/yield stress along the fracture face, fracture conductivity, fracture length, capillary pressure changes and formation damage on fracturing fluid cleanup in tight gas reservoirs. This model has been validated as against field data reported in the literature for the same reservoir. A 2-D, two-phase (gas/water) fracture propagation model is used to model our invasion zone and create the initial conditions for our clean-up model by distributing 200 bbls of water around the fracture. A 2-D, three-phase IMPES simulator, incorporating a yield-power-law-rheology has been developed in MATLAB to characterize fluid flow through a hydraulically fractured grid. The variation in polymer concentration along the fracture is computed from a material balance equation relating the initial polymer concentration to total volume of injected fluid and fracture volume. All governing equations and the methods employed have been adequately reported to permit easy replication of results. The effect of increasing capillary pressure in the formation simulated in this study resulted in a 10.4% decrease in cumulative production after 100 days of fluid recovery. Increasing the breaker concentration from 5-15 gal/Mgal on the yield stress and fluid viscosity of a 200 lb/Mgal guar fluid resulted in a 10.83% increase in cumulative gas production. For tight gas formations (k=0.05 md), fluid recovery increases with increasing shut-in time, increasing fracture conductivity and fracture length, irrespective of the yield stress of the fracturing fluid. Mechanical induced formation damage combined with hydraulic damage tends to be the most significant. Several correlations have been developed relating pressure distribution and polymer concentration to distance along the fracture face and average polymer concentration variation with injection time. The gradient in yield stress distribution along the fracture face becomes steeper with increasing polymer concentration. The rate at which the yield stress (τ_o) is increasing is found to be proportional to the square of the volume of fluid lost to the formation. Finally, an improvement on previous results was achieved through simulating yield stress variation along the fracture face rather than assuming constant values because fluid loss to the formation and the polymer concentration distribution along the fracture face decreases as we move away from the injection well. The novelty of this three-phase flow model lies in its ability to (i) Simulate yield stress variation with fluid loss volume along the fracture face for different initial guar concentrations. (ii) Simulate increasing breaker activity on yield stress and broken gel viscosity and the effect of (i) and (ii) on cumulative gas production within reasonable computational time.Keywords: formation damage, hydraulic fracturing, polymer cleanup, multiphase flow numerical simulation
Procedia PDF Downloads 1301133 A Hyperflexion Hallux Mallet Injury: A Case Report
Authors: Tan G. K. Y., Chew M. S. J., Sajeev S., Vellasamy A.
Abstract:
Injuries of the extensor hallucis longus (EHL) tendon are a rare phenomenon, with most occurring due to lacerations or penetrating injuries. Closed traumatic ruptures of the EHL are described as “Mallet injuries of the toe”. These can be classified as bony or soft mallet injuries depending on the presence or absence of a fracture at the insertion site of the EHL tendon in the distal phalanx. We present a case of a 33-year-old woman who presented with a hyperflexion injury to the left big toe with an inability to extend the big toe. Ultrasound showed a complete rupture of the EHL tendon with retraction proximal to the hallucal interphalangeal joint of the big toe. The patient was treated through transarticular pinning and repair using the Arthrex Mini Bio-Suture Tak with a 2-0 fibre wire. Six months postoperatively, the patient had symmetrical EHL power and full range of motion of the toe. The lessons to be drawn from this case report are that isolated hallux mallet injuries are rare and can be easily missed in the absence of penetrating wounds. Patients who have such injuries should be investigated early with the appropriate imaging techniques, such as ultrasound or MRI, and treated surgically.Keywords: hallux mallet, extensor hallucis longus tendon, extensor hallucis longus
Procedia PDF Downloads 791132 Designing and Analyzing Sensor and Actuator of a Nano/Micro-System for Fatigue and Fracture Characterization of Nanomaterials
Authors: Mohammad Reza Zamani Kouhpanji
Abstract:
This paper presents a MEMS/NEMS device for fatigue and fracture characterization of nanomaterials. This device can apply static loads, cyclic loads, and their combinations in nanomechanical experiments. It is based on the electromagnetic force induced between paired parallel wires carrying electrical currents. Using this concept, the actuator and sensor parts of the device were designed and analyzed while considering the practical limitations. Since the PWCC device only uses two wires for actuation part and sensing part, its fabrication process is extremely easier than the available MEMS/NEMS devices. The total gain and phase shift of the MEMS/NEMS device were calculated and investigated. Furthermore, the maximum gain and sensitivity of the MEMS/NEMS device were studied to demonstrate the capability and usability of the device for wide range of nanomaterials samples. This device can be readily integrated into SEM/TEM instruments to provide real time study of the mechanical behaviors of nanomaterials as well as their fatigue and fracture properties, softening or hardening behaviors, and initiation and propagation of nanocracks.Keywords: sensors and actuators, MEMS/NEMS devices, fatigue and fracture nanomechanical testing device, static and cyclic nanomechanical testing device
Procedia PDF Downloads 2971131 A Study of Recent Contribution on Simulation Tools for Network-on-Chip
Authors: Muthana Saleh Alalaki, Michael Opoku Agyeman
Abstract:
The growth in the number of Intellectual Properties (IPs) or the number of cores on the same chip becomes a critical issue in System-on-Chip (SoC) due to the intra-communication problem between the chip elements. As a result, Network-on-Chip (NoC) has emerged as a system architecture to overcome intra-communication issues. This paper presents a study of recent contributions on simulation tools for NoC. Furthermore, an overview of NoC is covered as well as a comparison between some NoC simulators to help facilitate research in on-chip communication.Keywords: WiNoC, simulation tool, network-on-chip, SoC
Procedia PDF Downloads 4981130 Liraglutide Augments Extra Body Weight Loss after Sleeve Gastrectomy without Change in Intrahepatic and Intra-Pancreatic Fat in Obese Individuals: Randomized, Controlled Study
Authors: Ashu Rastogi, Uttam Thakur, Jimmy Pathak, Rajesh Gupta, Anil Bhansali
Abstract:
Introduction: Liraglutide is known to induce weight loss and metabolic benefits in obese individuals. However, its effect after sleeve gastrectomy are not known. Methods: People with obesity (BMI>27.5 kg/m2) underwent LSG. Subsequently, participants were randomized to receive either 0.6mg liraglutide subcutaneously daily from 6 week post to be continued till 24 week (L-L group) or placebo (L-P group). Patients were assessed before surgery (baseline) and 6 weeks, 12weeks, 18weeks and 24weeks after surgery for height, weight, waist and hip circumference, BMI, body fat percentage, HbA1c, fasting C-peptide, fasting insulin, HOMA-IR, HOMA-β, GLP-1 levels (after standard OGTT). MRI abdomen was performed prior to surgery and at 24weeks post operatively for the estimation of intrapancreatic and intrahepatic fat content. Outcome measures: Primary outcomes were changes in metabolic variables of fasting and stimulated GLP-1 levels, insulin, c-peptide, plasma glucose levels. Secondary variables were indices of insulin resistance HOMA-IR, Matsuda index; and pancreatic and hepatic steatosis. Results: Thirty-eight patients undergoing LSG were screened and 29 participants were enrolled. Two patients withdrew consent and one patient died of acute coronary event. 26 patients were randomized and data analysed. Median BMI was 40.73±3.66 and 46.25±6.51; EBW of 49.225±11.14 and 651.48±4.85 in the L-P and L-L group, respectively. Baseline FPG was 132±51.48, 125±39.68; fasting insulin 21.5±13.99, 13.15±9.20, fasting GLP-1 2.4± .37, 2.4± .32, AUC GLP-1 340.78± 44 and 332.32 ± 44.1, HOMA-IR 7.0±4.2 and 4.42±4.5 in the L-P and L-L group, respectively. EBW loss was 47± 13.20 and 65.59± 24.20 (p<0.05) in the placebo versus liraglutide group. However, we did not observe inter-group difference in metabolic parameters between the groups in spite of significant intra-group changes after 6 months of LSG. Intra-pancreatic fat prior to surgery was 3.21±1.7 and 2.2±0.9 (p=0.38) that decreased to 2.14±1.8 and 1.06±0.8 (p=0.25) at 6 months in L-P and L-L group, respectively. Similarly, intra-pancreatic fat was 1.97±0.27 and 1.88±0.36 (p=0.361) at baseline that decreased to 1.14±0.44 and 1.36±0.47 (p=0.465) at 6 months in L-P and L-L group, respectively. Conclusion: Liraglutide augments extra body weight loss after sleeve gastrectomy. A decrease in intra-pancreatic and intra-hepatic fat is noticed after bariatric surgery without additive benefit of liraglutide administration.Keywords: sleeve gastrectomy, liraglutide, intra-pancreatic fat, insulin
Procedia PDF Downloads 1931129 Fracture Mechanics Modeling of a Shear-Cracked RC Beams Shear-Strengthened with FRP Sheets
Authors: Shahriar Shahbazpanahi, Alaleh Kamgar
Abstract:
So far, the conventional experimental and theoretical analysis in fracture mechanics have been applied to study concrete flexural- cracked beams, which are strengthened using fiber reinforced polymer (FRP) composite sheets. However, there is still little knowledge about the shear capacity of a side face FRP- strengthened shear-cracked beam. A numerical analysis is herein presented to model the fracture mechanics of a four-point RC beam, with two inclined initial notch on the supports, which is strengthened with side face FRP sheets. In the present study, the shear crack is forced to conduct by using an initial notch in supports. The ABAQUS software is used to model crack propagation by conventional cohesive elements. It is observed that the FRP sheets play important roles in preventing the propagation of shear cracks.Keywords: crack, FRP, shear, strengthening
Procedia PDF Downloads 5501128 Positive Effect of Manipulated Virtual Kinematic Intervention in Individuals with Traumatic Stiff Shoulder: Pilot Study
Authors: Isabella Schwartz, Ori Safran, Naama Karniel, Michal Abel, Adina Berko, Martin Seyres, Tamir Tsoar, Sigal Portnoy
Abstract:
Virtual Reality allows to manipulate the patient’s perception, thereby providing a motivational addition to real-time biofeedback exercises. We aimed to test the effect of manipulated virtual kinematic intervention on measures of active and passive Range of Motion (ROM), pain, and disability level in individuals with traumatic stiff shoulder. In a double-blinded study, patients with stiff shoulder following proximal humerus fracture and non-operative treatment were randomly divided into a non-manipulated feedback group (NM-group; N=6) and a manipulated feedback group (M-group; N=7). The shoulder ROM, pain, and the Disabilities of the Arm, Shoulder and Hand (DASH) scores were tested at baseline and after the 6 sessions, during which the subjects performed shoulder flexion and abduction in front of a graphic visualization of the shoulder angle. The biofeedback provided to the NM-group was the actual shoulder angle and the feedback provided to the M-group was manipulated so that 10° were constantly subtracted from the actual angle detected by the motion capture system. The M-group showed greater improvement in the active flexion ROM, with median and interquartile range of 197.1 (140.5-425.0) compared to 142.5 (139.1-151.3) for the NM-group (p=.046). Also, the M-group showed greater improvement in the DASH scores, with median and interquartile range of 67.7 (52.8-86.2) compared to 89.7 (83.8-98.3) for the NM-group (p=.022). Manipulated intervention is beneficial in individuals with traumatic stiff shoulder and should be further tested for other populations with orthopedic injuries.Keywords: virtual reality, biofeedback, shoulder pain, range of motion
Procedia PDF Downloads 1251127 Application of the Experimental Planning Design to the Notched Precracked Tensile Fracture of Composite
Authors: N. Mahmoudi, B. Guedim
Abstract:
Composite materials have important assets compared to traditional materials. They bring many functional advantages: lightness, mechanical resistance and chemical, etc. In the present study we examine the effect of a circular central notch and a precrack on the tensile fracture of two woven composite materials. The tensile tests were applied to a standardized specimen, notched and a precracked (orientation of the crack 0°, 45°, and 90°). These tensile tests were elaborated according to an experimental planning design of the type 23.31 requiring 24 experiments with three repetitions. By the analysis of regression, we obtained a mathematical model describing the maximum load according to the influential parameters (hole diameter, precrack length, angle of a precrack orientation). The specimens precracked at 90° have a better behavior than those having a precrack at 45° and still better than those having of the precracks oriented at 0°. In addition the maximum load is inversely proportional to the notch size.Keywords: polymer matrix, glasses, fracture, precracks
Procedia PDF Downloads 3441126 Fracture Properties Investigation of Artocarpus odoratissimus Composite with Polypropylene (PP)
Authors: M. Kamal M. Shah, Al Fareez Bin Aslie, O. Irma Wani, J. Sahari
Abstract:
Wood plastic composites (WPC) were made using matrix of polypropylene (PP) thermoplastic resin with wood fiber from Artocarpus Odoratissimus as filler. The purpose of this project is to investigate the fracture properties of Artocarpus odoratissimus composite with PP. The WPC were manufactured by hot-press technique with varying formulations which are 10:0 (100% pure PP), 50:50 (40 g of wood fiber and 40 g of PP) and 60:40 (48 g of wood fiber and 32 g of PP). The mechanical properties were investigated. Tensile and flexural were carried out according to ASTM D 638 and ASTM D 790. The results were analysed to calculate the tensile strength. Tensile strength at break is ranged from 13.2 N/mm2 to 21.7 N/mm2 while, the flexural strength obtained is varying from 14.7 N/mm2 to 31.1 N/mm2. The results of the experiment showed that tensile and flexural properties of the composite were increased with the adding of wood fiber material. Finally, the Scanning Electron Microscope (SEM), have been done to study the fracture behavior of the WPC specimens.Keywords: Artocarpus odoratissimus, polypropylene thermoplastic, wood fiber, WPC
Procedia PDF Downloads 4001125 Fracture Toughness Characterizations of Single Edge Notch (SENB) Testing Using DIC System
Authors: Amr Mohamadien, Ali Imanpour, Sylvester Agbo, Nader Yoosef-Ghodsi, Samer Adeeb
Abstract:
The fracture toughness resistance curve (e.g., J-R curve and crack tip opening displacement (CTOD) or δ-R curve) is important in facilitating strain-based design and integrity assessment of oil and gas pipelines. This paper aims to present laboratory experimental data to characterize the fracture behavior of pipeline steel. The influential parameters associated with the fracture of API 5L X52 pipeline steel, including different initial crack sizes, were experimentally investigated for a single notch edge bend (SENB). A total of 9 small-scale specimens with different crack length to specimen depth ratios were conducted and tested using single edge notch bending (SENB). ASTM E1820 and BS7448 provide testing procedures to construct the fracture resistance curve (Load-CTOD, CTOD-R, or J-R) from test results. However, these procedures are limited by standard specimens’ dimensions, displacement gauges, and calibration curves. To overcome these limitations, this paper presents the use of small-scale specimens and a 3D-digital image correlation (DIC) system to extract the parameters required for fracture toughness estimation. Fracture resistance curve parameters in terms of crack mouth open displacement (CMOD), crack tip opening displacement (CTOD), and crack growth length (∆a) were carried out from test results by utilizing the DIC system, and an improved regression fitting resistance function (CTOD Vs. crack growth), or (J-integral Vs. crack growth) that is dependent on a variety of initial crack sizes was constructed and presented. The obtained results were compared to the available results of the classical physical measurement techniques, and acceptable matchings were observed. Moreover, a case study was implemented to estimate the maximum strain value that initiates the stable crack growth. This might be of interest to developing more accurate strain-based damage models. The results of laboratory testing in this study offer a valuable database to develop and validate damage models that are able to predict crack propagation of pipeline steel, accounting for the influential parameters associated with fracture toughness.Keywords: fracture toughness, crack propagation in pipeline steels, CTOD-R, strain-based damage model
Procedia PDF Downloads 631124 A Single-Use Endoscopy System for Identification of Abnormalities in the Distal Oesophagus of Individuals with Chronic Reflux
Authors: Nafiseh Mirabdolhosseini, Jerry Zhou, Vincent Ho
Abstract:
The dramatic global rise in acid reflux has also led to oesophageal adenocarcinoma (OAC) becoming the fastest-growing cancer in developed countries. While gastroscopy with biopsy is used to diagnose OAC patients, this labour-intensive and expensive process is not suitable for population screening. This study aims to design, develop, and implement a minimally invasive system to capture optical data of the distal oesophagus for rapid screening of potential abnormalities. To develop the system and understand user requirements, a user-centric approach was employed by utilising co-design strategies. Target users’ segments were identified, and 38 patients and 14 health providers were interviewed. Next, the technical requirements were developed based on consultations with the industry. A minimally invasive optical system was designed and developed considering patient comfort. This system consists of the sensing catheter, controller unit, and analysis program. Its procedure only takes 10 minutes to perform and does not require cleaning afterward since it has a single-use catheter. A prototype system was evaluated for safety and efficacy for both laboratory and clinical performance. This prototype performed successfully when submerged in simulated gastric fluid without showing evidence of erosion after 24 hours. The system effectively recorded a video of the mid-distal oesophagus of a healthy volunteer (34-year-old male). The recorded images were used to develop an automated program to identify abnormalities in the distal oesophagus. Further data from a larger clinical study will be used to train the automated program. This system allows for quick visual assessment of the lower oesophagus in primary care settings and can serve as a screening tool for oesophageal adenocarcinoma. In addition, this system is able to be coupled with 24hr ambulatory pH monitoring to better correlate oesophageal physiological changes with reflux symptoms. It also can provide additional information on lower oesophageal sphincter functions such as opening times and bolus retention.Keywords: endoscopy, MedTech, oesophageal adenocarcinoma, optical system, screening tool
Procedia PDF Downloads 881123 Evaluation of Fracture Resistance and Moisture Damage of Hot Mix Asphalt Using Plastic Coated Aggregates
Authors: Malleshappa Japagal, Srinivas Chitragar
Abstract:
The use of waste plastic in pavement is becoming important alternative worldwide for disposal of plastic as well as to improve the stability of pavement and to meet out environmental issues. However, there are still concerns on fatigue and fracture resistance of Hot Mix Asphalt with the addition of plastic waste, (HMA-Plastic mixes) and moisture damage potential. The present study was undertaken to evaluate fracture resistance of HMA-Plastic mixes using semi-circular bending (SCB) test and moisture damage potential by Indirect Tensile strength (ITS) test using retained tensile strength (TSR). In this study, a dense graded asphalt mix with 19 mm nominal maximum aggregate size was designed in the laboratory using Marshall Mix design method. Aggregates were coated with different percentages of waste plastic (0%, 2%, 3% and 4%) by weight of aggregate and performance evaluation of fracture resistance and Moisture damage was carried out. The following parameters were estimated for the mixes: J-Integral or Jc, strain energy at failure, peak load at failure, and deformation at failure. It was found that the strain energy and peak load of all the mixes decrease with an increase in notch depth, indicating that increased percentage of plastic waste gave better fracture resistance. The moisture damage potential was evaluated by Tensile strength ratio (TSR). The experimental results shown increased TRS value up to 3% addition of waste plastic in HMA mix which gives better performance hence the use of waste plastic in road construction is favorable.Keywords: hot mix asphalt, semi circular bending, marshall mix design, tensile strength ratio
Procedia PDF Downloads 3061122 The Crack Propagation on Glass in Laser Thermal Cleavage
Authors: Jehnming Lin
Abstract:
In the laser cleavage of glass, the laser is mostly adopted as a heat source to generate a thermal stress state on the substrates. The crack propagation of the soda-lime glass in the laser thermal cleavage with the straight-turning paths was investigated in this study experimentally and numerically. The crack propagation was visualized by a high speed camera with the off-line examination on the micro-crack propagation. The temperature and stress distributions induced by the laser heat source were calculated by ANSYS software based on the finite element method (FEM). With the cutting paths in various turning directions, the experimental and numerical results were in comparison and verified. The fracture modes due to the normal and shear stresses were verified at the turning point of the laser cleavage path. It shows a significant variation of the stress profiles along the straight-turning paths and causes a change on the fracture modes.Keywords: laser cleavage, glass, fracture, stress analysis
Procedia PDF Downloads 2301121 An Investigation of the Fracture Behavior of Model MgO-C Refractories Using the Discrete Element Method
Authors: Júlia Cristina Bonaldo, Christophe L. Martin, Martiniano Piccico, Keith Beale, Roop Kishore, Severine Romero-Baivier
Abstract:
Refractory composite materials employed in steel casting applications are prone to cracking and material damage because of the very high operating temperature (thermal shock) and mismatched properties of the constituent phases. The fracture behavior of a model MgO-C composite refractory is investigated to quantify and characterize its thermal shock resistance, employing a cold crushing test and Brazilian test with fractographic analysis. The discrete element method (DEM) is used to generate numerical refractory composites. The composite in DEM is represented by an assembly of bonded particle clusters forming perfectly spherical aggregates and single spherical particles. For the stresses to converge with a low standard deviation and a minimum number of particles to allow reasonable CPU calculation time, representative volume element (RVE) numerical packings are created with various numbers of particles. Key microscopic properties are calibrated sequentially by comparing stress-strain curves from crushing experimental data. Comparing simulations with experiments also allows for the evaluation of crack propagation, fracture energy, and strength. The crack propagation during Brazilian experimental tests is monitored with digital image correlation (DIC). Simulations and experiments reveal three distinct types of fracture. The crack may spread throughout the aggregate, at the aggregate-matrix interface, or throughout the matrix.Keywords: refractory composite, fracture mechanics, crack propagation, DEM
Procedia PDF Downloads 811120 Remote Electroacupuncture Analgesia at Contralateral LI4 Acupoint in Complete Freund's Adjuvant-Induced Inflammatory Hindpaw Pain
Authors: Tong-Chien Wu, Ching-Liang Hsieh, Yi-Wen Lin
Abstract:
There are accumulating evidences surrounding the therapeutic effect of electroacupuncture (EA). Local EA can reliably attenuate inflammatory pain in mouse with unclear mechanisms. However, the effect of EA on distal and contralateral acupoint for pain control has been rarely studied and the result was controversial. Here in our study, we found that inflammatory hindpaw pain in mouth, which was induced by injecting the complete Freund’s adjuvant (CFA) 2 days ago can be alleviated immediately after 2Hz 15mins EA treatment at contralateral forefoot acupoint LI4 through both mechanic and thermal behavior test, while sham acupoint group is not. The efficacy was observed to be more obvious after the second round of EA treatment on the following day. This analgesic effect is produced by applying EA to a site remote from the painful area. The present study provides a powerful experimental animal model that can be used for investigating the unique physiological mechanisms involved in acupuncture analgesia.Keywords: remote electroacupuncture, distal EA, pain control, anti-inflammation
Procedia PDF Downloads 1881119 Numerical Simulation of Hydraulic Fracture Propagation in Marine-continental Transitional Tight Sandstone Reservoirs by Boundary Element Method: A Case Study of Shanxi Formation in China
Authors: Jiujie Cai, Fengxia LI, Haibo Wang
Abstract:
After years of research, offshore oil and gas development now are shifted to unconventional reservoirs, where multi-stage hydraulic fracturing technology has been widely used. However, the simulation of complex hydraulic fractures in tight reservoirs is faced with geological and engineering difficulties, such as large burial depths, sand-shale interbeds, and complex stress barriers. The objective of this work is to simulate the hydraulic fracture propagation in the tight sandstone matrix of the marine-continental transitional reservoirs, where the Shanxi Formation in Tianhuan syncline of the Dongsheng gas field was used as the research target. The characteristic parameters of the vertical rock samples with rich beddings were clarified through rock mechanics experiments. The influence of rock mechanical parameters, vertical stress difference of pay-zone and bedding layer, and fracturing parameters (such as injection rates, fracturing fluid viscosity, and number of perforation clusters within single stage) on fracture initiation and propagation were investigated. In this paper, a 3-D fracture propagation model was built to investigate the complex fracture propagation morphology by boundary element method, considering the strength of bonding surface between layers, vertical stress difference and fracturing parameters (such as injection rates, fluid volume and viscosity). The research results indicate that on the condition of vertical stress difference (3 MPa), the fracture height can break through and enter the upper interlayer when the thickness of the overlying bedding layer is 6-9 m, considering effect of the weak bonding surface between layers. The fracture propagates within the pay zone when overlying interlayer is greater than 13 m. Difference in fluid volume distribution between clusters could be more than 20% when the stress difference of each cluster in the segment exceeds 2MPa. Fracture cluster in high stress zones cannot initiate when the stress difference in the segment exceeds 5MPa. The simulation results of fracture height are much higher if the effect of weak bonding surface between layers is not involved. By increasing the injection rates, increasing fracturing fluid viscosity, and reducing the number of clusters within single stage can promote the fracture height propagation through layers. Optimizing the perforation position and reducing the number of perforations can promote the uniform expansion of fractures. Typical curves of fracture height estimation were established for the tight sandstone of the Lower Permian Shanxi Formation. The model results have good consistency with micro-seismic monitoring results of hydraulic fracturing in Well 1HF.Keywords: fracture propagation, boundary element method, fracture height, offshore oil and gas, marine-continental transitional reservoirs, rock mechanics experiment
Procedia PDF Downloads 1271118 Interface Fracture of Sandwich Composite Influenced by Multiwalled Carbon Nanotube
Authors: Alak Kumar Patra, Nilanjan Mitra
Abstract:
Higher strength to weight ratio is the main advantage of sandwich composite structures. Interfacial delamination between the face sheet and core is a major problem in these structures. Many research works are devoted to improve the interfacial fracture toughness of composites majorities of which are on nano and laminated composites. Work on influence of multiwalled carbon nano-tubes (MWCNT) dispersed resin system on interface fracture of glass-epoxy PVC core sandwich composite is extremely limited. Finite element study is followed by experimental investigation on interface fracture toughness of glass-epoxy (G/E) PVC core sandwich composite with and without MWCNT. Results demonstrate an improvement in interface fracture toughness values (Gc) of samples with a certain percentages of MWCNT. In addition, dispersion of MWCNT in epoxy resin through sonication followed by mixing of hardener and vacuum resin infusion (VRI) technology used in this study is an easy and cost effective methodology in comparison to previously adopted other methods limited to laminated composites. The study also identifies the optimum weight percentage of MWCNT addition in the resin system for maximum performance gain in interfacial fracture toughness. The results agree with finite element study, high-resolution transmission electron microscope (HRTEM) analysis and fracture micrograph of field emission scanning electron microscope (FESEM) investigation. Interface fracture toughness (GC) of the DCB sandwich samples is calculated using the compliance calibration (CC) method considering the modification due to shear. Compliance (C) vs. crack length (a) data of modified sandwich DCB specimen is fitted to a power function of crack length. The calculated mean value of the exponent n from the plots of experimental results is 2.22 and is different from the value (n=3) prescribed in ASTM D5528-01for mode 1 fracture toughness of laminate composites (which is the basis for modified compliance calibration method). Differentiating C with respect to crack length (a) and substituting it in the expression GC provides its value. The research demonstrates improvement of 14.4% in peak load carrying capacity and 34.34% in interface fracture toughness GC for samples with 1.5 wt% MWCNT (weight % being taken with respect to weight of resin) in comparison to samples without MWCNT. The paper focuses on significant improvement in experimentally determined interface fracture toughness of sandwich samples with MWCNT over the samples without MWCNT using much simpler method of sonication. Good dispersion of MWCNT was observed in HRTEM with 1.5 wt% MWCNT addition in comparison to other percentages of MWCNT. FESEM studies have also demonstrated good dispersion and fiber bridging of MWCNT in resin system. Ductility is also observed to be higher for samples with MWCNT in comparison to samples without.Keywords: carbon nanotube, epoxy resin, foam, glass fibers, interfacial fracture, sandwich composite
Procedia PDF Downloads 3031117 Sport-Related Hand and Wrist Injuries Treatment
Authors: Sergei Kosarev
Abstract:
Wrong treatment tactics for hand and wrist sport-related injuries can lead to the inability to play sports in the future. It is especially important for professional athletes. The members of the Russian Olympic Team are treated in our hospital -Federal Clinical Research Center (Moscow). For their treatment, we use minimally invasive methods such as wrist arthroscopy and also orthobiologics procedures. In 2022 we had cases with scaphoid fracture and TFCC injuries. In all the cases, we were using the arthroscopy technic for treatment. The scaphoid fracture was fixed by K-wires with free bone grafting. For TFCC injures we used transossal sutures. Rehabilitation started the next day after surgery. Rehabilitation included hand therapy and physiotherapy. All athletes returned to the sport after 8-12 weeks after surgery. One of them had pain in the wrist after 12 weeks after surgery, not more than 4 point VAS. Pain syndrome was blocked after 2 PRP injections in the ulnar side of the wrist.Keywords: sport trauma, wrist arthroscopy, wrist pain, scaphoid fracture
Procedia PDF Downloads 991116 The Influence of Fiber Fillers on the Bonding Safety of Structural Adhesives: A Fracture Analytical Evaluation
Authors: Brandtner-Hafner Martin
Abstract:
Adhesives have established themselves as an innovative joining technology in the industry. Their strengths lie in joining different materials, avoiding structural weakening as in welding or screwing, and enabling lightweight construction methods. Now there are a variety of ways to improve the efficiency and effectiveness of bonded joints. One way is to add fiber fillers. This leads to an improvement in adhesion and cohesion (structural integrity). In this study, the effectiveness of fiber-modified adhesives for bonding different construction materials is reviewed. A series of experimental tests were performed using the fracture analytical GF principle to study the adhesive bonding safety and performance of the joint. Three different structural adhesive systems based on epoxy, CA/A hybrid, and PUR were modified with different fiber materials on different substrates. The results show that significant performance improvements can be achieved and that bonding reliability can be sustainably increased.Keywords: fiber-modified adhesives, bonding safety, GF-principle, fracture analysis
Procedia PDF Downloads 1731115 An Integrated Approach to the Carbonate Reservoir Modeling: Case Study of the Eastern Siberia Field
Authors: Yana Snegireva
Abstract:
Carbonate reservoirs are known for their heterogeneity, resulting from various geological processes such as diagenesis and fracturing. These complexities may cause great challenges in understanding fluid flow behavior and predicting the production performance of naturally fractured reservoirs. The investigation of carbonate reservoirs is crucial, as many petroleum reservoirs are naturally fractured, which can be difficult due to the complexity of their fracture networks. This can lead to geological uncertainties, which are important for global petroleum reserves. The problem outlines the key challenges in carbonate reservoir modeling, including the accurate representation of fractures and their connectivity, as well as capturing the impact of fractures on fluid flow and production. Traditional reservoir modeling techniques often oversimplify fracture networks, leading to inaccurate predictions. Therefore, there is a need for a modern approach that can capture the complexities of carbonate reservoirs and provide reliable predictions for effective reservoir management and production optimization. The modern approach to carbonate reservoir modeling involves the utilization of the hybrid fracture modeling approach, including the discrete fracture network (DFN) method and implicit fracture network, which offer enhanced accuracy and reliability in characterizing complex fracture systems within these reservoirs. This study focuses on the application of the hybrid method in the Nepsko-Botuobinskaya anticline of the Eastern Siberia field, aiming to prove the appropriateness of this method in these geological conditions. The DFN method is adopted to model the fracture network within the carbonate reservoir. This method considers fractures as discrete entities, capturing their geometry, orientation, and connectivity. But the method has significant disadvantages since the number of fractures in the field can be very high. Due to limitations in the amount of main memory, it is very difficult to represent these fractures explicitly. By integrating data from image logs (formation micro imager), core data, and fracture density logs, a discrete fracture network (DFN) model can be constructed to represent fracture characteristics for hydraulically relevant fractures. The results obtained from the DFN modeling approaches provide valuable insights into the East Siberia field's carbonate reservoir behavior. The DFN model accurately captures the fracture system, allowing for a better understanding of fluid flow pathways, connectivity, and potential production zones. The analysis of simulation results enables the identification of zones of increased fracturing and optimization opportunities for reservoir development with the potential application of enhanced oil recovery techniques, which were considered in further simulations on the dual porosity and dual permeability models. This approach considers fractures as separate, interconnected flow paths within the reservoir matrix, allowing for the characterization of dual-porosity media. The case study of the East Siberia field demonstrates the effectiveness of the hybrid model method in accurately representing fracture systems and predicting reservoir behavior. The findings from this study contribute to improved reservoir management and production optimization in carbonate reservoirs with the use of enhanced and improved oil recovery methods.Keywords: carbonate reservoir, discrete fracture network, fracture modeling, dual porosity, enhanced oil recovery, implicit fracture model, hybrid fracture model
Procedia PDF Downloads 751114 Effect of Perioperative Multimodal Analgesia on Postoperative Opioid Consumption and Complications in Elderly Traumatic Hip Fracture Patients: A Systematic Review of Randomised Controlled Trials
Authors: Raheel Shakoor Siddiqui, Shahbaz Malik, Manikandar Srinivas Cheruvu, Sanjay Narayana Murthy, Livio DiMascio
Abstract:
Background: elderly traumatic hip fracture patients frequently present to trauma services globally. Rising low energy falls amongst an osteoporotic aging population is the commonest cause for injury. Hip fractures in this population are a major cause for severe pain, morbidity and mortality. The term hip fracture is interchangeable with neck of femur fracture, fractured neck of femur or proximal femur fracture. Hip fracture pain management protocols and guidelines suggest conventional analgesia, nerve block and opioid based treatment as rescue analgesia. There is a current global opioid crisis with overuse, abuse and dependence. Adverse opioid related complications in vulnerable elderly patients further adds to morbidity and mortality. Systematic reviews in literature have evidenced superiority of multimodal analgesia in osteoarthritic primary joint replacements compared to opioids however, this has not yet been conducted for elderly traumatic hip fracture patients. Aims: The primary aim of this systematic review is to provide standardised evidence following Cochrane and PRISMA guidance in determining advantages of perioperative multimodal analgesia over conventional opioid based treatments in elderly traumatic hip fractures. Methods: 5 databases were searched from January 2000-2023 which identified 8 randomised controlled trials and 446 total participants. These trials met defined PICOS eligibility criteria of patient mean age ≥ 65 years presenting with a unilateral traumatic fractured neck of femur for operative intervention. Analgesic intervention with perioperative multimodal analgesia has been compared to conventional opioid based analgesia. Outcomes of interest include, primarily, the change in postoperative opioid consumption within a 0-30 postoperative period and secondarily, the change in postoperative adverse events and complications. A qualitative synthesis has been performed due to clinical heterogenicity and variance amongst trials. Results: GRADE evidence of moderate quality supports perioperative multimodal analgesia leads to a reduction in postoperative opioid consumption however, low quality evidence supports a reduction of adverse effects and complications. Conclusion: Perioperative multimodal analgesia whether used preoperative, intraoperative and/or postoperative leads to a reduction in postoperative opioid consumption for elderly traumatic hip fracture patients. This review recommends the use of perioperative multimodal analgesia as part of hip fracture pain protocols however, caution and clinical judgement should be used as the risk of adverse effects may not be lower.Keywords: trauma, orthopaedics, hip, fracture, neck of femur fracture, analgesia, multimodal analgesia, opioid
Procedia PDF Downloads 971113 Unidentified Remains with Extensive Bone Disease without a Clear Diagnosis
Authors: Patricia Shirley Almeida Prado, Selma Paixão Argollo, Maria De Fátima Teixeira Guimarães, Leticia Matos Sobrinho
Abstract:
Skeletal differential diagnosis is essential in forensic anthropology in order to differentiate skeletal trauma from normal osseous variation and pathological processes. Thus, part of forensic anthropological field is differentiate skeletal criminal injuries from the normal skeletal variation (bone fusion or nonunion, transitional vertebrae and other non-metric traits), non-traumatic skeletal pathology (myositis ossificans, arthritis, bone metastasis, osteomyelitis) from traumatic skeletal pathology (myositis ossificans traumatic) avoiding misdiagnosis. This case shows the importance of effective pathological diagnosis in order to accelerate the identification process of skeletonized human remains. THE CASE: An unidentified skeletal remains at the medico legal institute Nina Rodrigues-Salvador, of a male young adult (29 to 40 years estimated) showing a massive heterotopic ossification on its right tibia at upper epiphysis and adjacent articular femur surface; an extensive ossification on the right clavicle (at the sternal extremity) also presenting an heterotopic ossification at right scapulae (upper third of scapulae lateral margin and infraglenoid tubercule) and at the head of right humerus at the shoulder joint area. Curiously, this case also shows an unusual porosity in certain vertebrae´s body and in some tarsal and carpal bones. Likewise, his left fifth metacarpal bones (right and left) showed a healed fracture which led both bones distorted. Based on identification, of pathological conditions in human skeletal remains literature and protocols these alterations can be misdiagnosed and this skeleton may present more than one pathological process. The anthropological forensic lab at Medico-legal Institute Nina Rodrigues in Salvador (Brazil) adopts international protocols to ancestry, sex, age and stature estimations, also implemented well-established conventions to identify pathological disease and skeletal alterations. The most compatible diagnosis for this case is hematogenous osteomyelitis due to following findings: 1: the healed fracture pattern at the clavicle showing a cloaca which is a pathognomonic for osteomyelitis; 2: the metacarpals healed fracture does not present cloaca although they developed a periosteal formation. 3: the superior articular surface of the right tibia shows an extensive inflammatory healing process that extends to adjacent femur articular surface showing some cloaca at tibia bone disease. 4: the uncommon porosities may result from hematogenous infectious process. The fractures probably have occurred in a different moments based on the healing process; the tibia injury is more extensive and has not been reorganized, while metacarpals and clavicle fracture is properly healed. We suggest that the clavicle and tibia´s fractures were infected by an existing infectious disease (syphilis, tuberculosis, brucellosis) or an existing syndrome (Gorham’s disease), which led to the development of osteomyelitis. This hypothesis is supported by the fact that different bones are affected in diverse levels. Like the metacarpals that do not show the cloaca, but then a periosteal new bone formation; then the unusual porosities do not show a classical osteoarthritic processes findings as the marginal osteophyte, pitting and new bone formation, they just show an erosive process without bone formation or osteophyte. To confirm and prove our hypothesis we are working on different clinical approaches like DNA, histopathology and other image exams to find the correct diagnostic.Keywords: bone disease, forensic anthropology, hematogenous osteomyelitis, human identification, human remains
Procedia PDF Downloads 3251112 Seismic Data Analysis of Intensity, Orientation and Distribution of Fractures in Basement Rocks for Reservoir Characterization
Authors: Mohit Kumar
Abstract:
Natural fractures are classified in two broad categories of joints and faults on the basis of shear movement in the deposited strata. Natural fracture always has high structural relationship with extensional or non-extensional tectonics and sometimes the result is seen in the form of micro cracks. Geological evidences suggest that both large and small-scale fractures help in to analyze the seismic anisotropy which essentially contribute into characterization of petro physical properties behavior associated with directional migration of fluid. We generally question why basement study is much needed as historically it is being treated as non-productive and geoscientist had no interest in exploration of these basement rocks. Basement rock goes under high pressure and temperature, and seems to be highly fractured because of the tectonic stresses that are applied to the formation along with the other geological factors such as depositional trend, internal stress of the rock body, rock rheology, pore fluid and capillary pressure. Sometimes carbonate rocks also plays the role of basement and igneous body e.g basalt deposited over the carbonate rocks and fluid migrate from carbonate to igneous rock due to buoyancy force and adequate permeability generated by fracturing. So in order to analyze the complete petroleum system, FMC (Fluid Migration Characterization) is necessary through fractured media including fracture intensity, orientation and distribution both in basement rock and county rock. Thus good understanding of fractures can lead to project the correct wellbore trajectory or path which passes through potential permeable zone generated through intensified P-T and tectonic stress condition. This paper deals with the analysis of these fracture property such as intensity, orientation and distribution in basement rock as large scale fracture can be interpreted on seismic section, however, small scale fractures show ambiguity in interpretation because fracture in basement rock lies below the seismic wavelength and hence shows erroneous result in identification. Seismic attribute technique also helps us to delineate the seismic fracture and subtle changes in fracture zone and these can be inferred from azimuthal anisotropy in velocity and amplitude and spectral decomposition. Seismic azimuthal anisotropy derives fracture intensity and orientation from compressional wave and converted wave data and based on variation of amplitude or velocity with azimuth. Still detailed analysis of fractured basement required full isotropic and anisotropic analysis of fracture matrix and surrounding rock matrix in order to characterize the spatial variability of basement fracture which support the migration of fluid from basement to overlying rock.Keywords: basement rock, natural fracture, reservoir characterization, seismic attribute
Procedia PDF Downloads 1971111 The Effect of Nylon and Kevlar Stitching on the Mode I Fracture of Carbon/Epoxy Composites
Authors: Nisrin R. Abdelal, Steven L. Donaldson
Abstract:
Composite materials are widely used in aviation industry due to their superior properties; however, they are susceptible to delamination. Through-thickness stitching is one of the techniques to alleviate delamination. Kevlar is one of the most common stitching materials; in contrast, it is expensive and presents stitching fabrication challenges. Therefore, this study compares the performance of Kevlar with an inexpensive and easy-to-use nylon fiber in stitching to alleviate delamination. Three laminates of unidirectional carbon fiber-epoxy composites were manufactured using vacuum assisted resin transfer molding process. One panel was stitched with Kevlar, one with nylon, and one unstitched. Mode I interlaminar fracture tests were carried out on specimens from the three composite laminates, and the results were compared. Fractographic analysis using optical and scanning electron microscope were conducted to reveal the differences between stitching with Kevlar and nylon on the internal microstructure of the composite with respect to the interlaminar fracture toughness values.Keywords: carbon, delamination, Kevlar, mode I, nylon, stitching
Procedia PDF Downloads 2871110 Numerical Modelling of 3-D Fracture Propagation and Damage Evolution of an Isotropic Heterogeneous Rock with a Pre-Existing Surface Flaw under Uniaxial Compression
Authors: S. Mondal, L. M. Olsen-Kettle, L. Gross
Abstract:
Fracture propagation and damage evolution are extremely important for many industrial applications including mining industry, composite materials, earthquake simulations, hydraulic fracturing. The influence of pre-existing flaws and rock heterogeneity on the processes and mechanisms of rock fracture has important ramifications in many mining and reservoir engineering applications. We simulate the damage evolution and fracture propagation in an isotropic sandstone specimen containing a pre-existing 3-D surface flaw in different configurations under uniaxial compression. We apply a damage model based on the unified strength theory and solve the solid deformation and damage evolution equations using the Finite Element Method (FEM) with tetrahedron elements on unstructured meshes through the simulation software, eScript. Unstructured meshes provide higher geometrical flexibility and allow a more accurate way to model the varying flaw depth, angle, and length through locally adapted FEM meshes. The heterogeneity of rock is considered by initializing material properties using a Weibull distribution sampled over a cubic grid. In our model, we introduce a length scale related to the rock heterogeneity which is independent of the mesh size. We investigate the effect of parameters including the heterogeneity of the elastic moduli and geometry of the single flaw in the stress strain response. The generation of three typical surface cracking patterns, called wing cracks, anti-wing cracks and far-field cracks were identified, and these depend on the geometry of the pre-existing surface flaw. This model results help to advance our understanding of fracture and damage growth in heterogeneous rock with the aim to develop fracture simulators for different industry applications.Keywords: finite element method, heterogeneity, isotropic damage, uniaxial compression
Procedia PDF Downloads 2181109 Discrete Crack Modeling of Side Face FRP-Strengthened Concrete Beam
Authors: Shahriar Shahbazpanahi, Mohammad Hemen Jannaty, Alaleh Kamgar
Abstract:
Shear strengthening can be carried out in concrete structures by external fibre reinforced polymer (FRP). In the present investigation, a new fracture mechanics model is developed to model side face of strengthened concrete beam by external FRP. Discrete crack is simulated by a spring element with softening behavior ahead of the crack tip to model the cohesive zone in concrete. A truss element is used, parallel to the spring element, to simulate the energy dissipation rate by the FRP. The strain energy release rate is calculated directly by using a virtual crack closure technique and then, the crack propagation criterion is presented. The results are found acceptable when compared to previous experimental results and ABAQUS software data. It is observed that the length of the fracture process zone (FPZ) increases with the application of FRP in side face at the same load in comparison with that of the control beam.Keywords: FPZ, fracture, FRP, shear
Procedia PDF Downloads 534