Search results for: foreign control
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 12123

Search results for: foreign control

10713 Adsorptive Waste Heat Based Air-Conditioning Control Strategy for Automotives

Authors: Indrasen Raghupatruni, Michael Glora, Ralf Diekmann, Thomas Demmer

Abstract:

As the trend in automotive technology is fast moving towards hybridization and electrification to curb emissions as well as to improve the fuel efficiency, air-conditioning systems in passenger cars have not caught up with this trend and still remain as the major energy consumers amongst others. Adsorption based air-conditioning systems, e.g. with silica-gel water pair, which are already in use for residential and commercial applications, are now being considered as a technology leap once proven feasible for the passenger cars. In this paper we discuss a methodology, challenges and feasibility of implementing an adsorption based air-conditioning system in a passenger car utilizing the exhaust waste heat. We also propose an optimized control strategy with interfaces to the engine control unit of the vehicle for operating this system with reasonable efficiency supported by our simulation and validation results in a prototype vehicle, additionally comparing to existing implementations, simulation based as well as experimental. Finally we discuss the influence of start-stop and hybrid systems on the operation strategy of the adsorption air-conditioning system.

Keywords: adsorption air-conditioning, feasibility study, optimized control strategy, prototype vehicle

Procedia PDF Downloads 435
10712 Comparison of Proportional-Integral (P-I) and Integral-Propotional (I-P) Controllers for Speed Control in Vector Controlled Permanent Magnet Synchronous Motor Drive

Authors: V. Srikanth, K. Balasubramanian, Rajath R. Bhat, A. S. Arjun, Nandhu Venugopal, Ananthu Unnikrishnan

Abstract:

Indirect vector control is known to produce high performance in Permanent Magnet Synchronous Motor (PMSM) drives by decoupling flux and torque producing current components of stator current. The most commonly used controller or the vector control of AC motor is Proportional-Integral (P-I) controller. However, the P-I controller has some disadvantages such as high starting overshoot, sensitivity to controller gains and slower response to sudden disturbance. Therefore, the Integral-Proportional controller for PMSM drives to overcome the disadvantages of the P-I controller. Simulations results are presented and analyzed for both controllers and it is observed that Integral-Proportional (I-P) controllers give better responses than the traditional P-I controllers.

Keywords: PMSM, FOC, PI controller, IP controller

Procedia PDF Downloads 360
10711 Mothers and Moneymakers: A Case Study of How Citizen-Women Shape U.S. Marriage Migration Politics Online

Authors: Gina Longo

Abstract:

Social media, internet technology, and affordable travel have created avenues like tourism and internet chatrooms for Western women to meet foreign partners without paid, third-party intermediaries in regions like the Middle East/North Africa (MENA) and Sub-Saharan Africa (SSA), where men from mid-level developing countries meet and marry Western women and try to relocate. Foreign nationals who marry U.S. citizens have an expedited track to naturalization. U.S. immigration officials require that “green card” petitioning couples demonstrate that their relationships are “valid and subsisting” (i.e., for love) and not fraudulent (i.e., for immigration papers). These requirements are ostensibly gender- and racially-neutral, but migration itself is not; black and white women petitioners who seek partners from these regions and solicit advice from similar others about the potential obstacles to their petitions’ success online. Using an online ethnography and textual analysis of conversation threads on a large on-line immigration forum where U.S. petitioners exchange such information, this study examines how gendered and racialized standards of legitimacy are applied to family and sexuality and used discursively online among women petitioners differently to achieve “genuineness” and define “red flags” indicating potential marriage fraud. This paper argues that forum-women members police immigration requests even before cases reach an immigration officer, and use this social media platform to reconstruct gendered and racialized hierarchies of U.S. citizenship. Women petitioners use the formal criteria of U.S. immigration in ways that reveal gender and racial ideologies, expectations for conformity to a gendered hegemonic family ideal, and policing of women’s sexual agency, fertility, and desirability. These intersectional norms shape their online discussions about the suitability of marriages and of the migration of non-citizen male partners of color to the United States.

Keywords: marriage fraud, migration, online forums, women

Procedia PDF Downloads 120
10710 Improved Thermal Comfort in Cabin Aircraft with in-Seat Microclimate Conditioning Module

Authors: Mathieu Le Cam, Tejaswinee Darure, Mateusz Pawlucki

Abstract:

Climate control of cabin aircraft is traditionally conditioned as a single unit by the environmental control system. Cabin temperature is controlled by the crew while passengers of the aircraft have control on the gaspers providing fresh air from the above head area. The small nozzles are difficult to reach and adjust to meet the passenger’s needs in terms of flow and direction. More dedicated control over the near environment of each passenger can be beneficial in many situations. The European project COCOON, funded under Clean Sky 2, aims at developing and demonstrating a microclimate conditioning module (MCM) integrated into a standard economy 3-seat row. The system developed will lead to improved passenger comfort with more control on their personal thermal area. This study focuses on the assessment of thermal comfort of passengers in the cabin aircraft through simulation on the TAITherm modelling platform. A first analysis investigates thermal comfort and sensation of passengers in varying cabin environmental conditions: from cold to very hot scenarios, with and without MCM installed in the seats. The modelling platform is also used to evaluate the impact of different physiologies of passengers on their thermal comfort as well as different seat locations. Under the current cabin conditions, a passenger of a 50th percentile body size is feeling uncomfortably cool due to the high velocity cabin air ventilation. The simulation shows that the in-seat MCM developed in COCOON project improves the thermal comfort of the passenger.

Keywords: cabin aircraft, in-seat HVAC, microclimate conditioning module, thermal comfort

Procedia PDF Downloads 200
10709 The Future Control Rooms for Sustainable Power Systems: Current Landscape and Operational Challenges

Authors: Signe Svensson, Remy Rey, Anna-Lisa Osvalder, Henrik Artman, Lars Nordström

Abstract:

The electric power system is undergoing significant changes. Thereby, the operation and control are becoming partly modified, more multifaceted and automated, and thereby supplementary operator skills might be required. This paper discusses developing operational challenges in future power system control rooms, posed by the evolving landscape of sustainable power systems, driven in turn by the shift towards electrification and renewable energy sources. A literature review followed by interviews and a comparison to other related domains with similar characteristics, a descriptive analysis was performed from a human factors perspective. Analysis is meant to identify trends, relationships, and challenges. A power control domain taxonomy includes a temporal domain (planning and real-time operation) and three operational domains within the power system (generation, switching and balancing). Within each operational domain, there are different control actions, either in the planning stage or in the real-time operation, that affect the overall operation of the power system. In addition to the temporal dimension, the control domains are divided in space between a multitude of different actors distributed across many different locations. A control room is a central location where different types of information are monitored and controlled, alarms are responded to, and deviations are handled by the control room operators. The operators’ competencies, teamwork skills, team shift patterns as well as control system designs are all important factors in ensuring efficient and safe electricity grid management. As the power system evolves with sustainable energy technologies, challenges are found. Questions are raised regarding whether the operators’ tacit knowledge, experience and operation skills of today are sufficient to make constructive decisions to solve modified and new control tasks, especially during disturbed operations or abnormalities. Which new skills need to be developed in planning and real-time operation to provide efficient generation and delivery of energy through the system? How should the user interfaces be developed to assist operators in processing the increasing amount of information? Are some skills at risk of being lost when the systems change? How should the physical environment and collaborations between different stakeholders within and outside the control room develop to support operator control? To conclude, the system change will provide many benefits related to electrification and renewable energy sources, but it is important to address the operators’ challenges with increasing complexity. The control tasks will be modified, and additional operator skills are needed to perform efficient and safe operations. Also, the whole human-technology-organization system needs to be considered, including the physical environment, the technical aids and the information systems, the operators’ physical and mental well-being, as well as the social and organizational systems.

Keywords: operator, process control, energy system, sustainability, future control room, skill

Procedia PDF Downloads 95
10708 Deformation Behavior of Virgin and Polypropylene Modified Bituminous Mixture

Authors: Noor Zainab Habib, Ibrahim Kamaruddin, Madzlan Napiah

Abstract:

This paper present a part of research conducted to investigate the creep behavior of bituminous concrete mixture prepared with well graded using the dynamic creep test. The samples were prepared from unmodified control mix and Polypropylene modified bituminous mix. Unmodified or control mix was prepared with 80/100 grade bitumen while polypropylene modified mix was prepared using polypropylene PP polymer as modifier, blended with 80/100 Pen bitumen. The concentration of polymer in the blend was kept at 1%, 2%, and 3% by weight of bitumen content. For Dynamic Creep Test, Marshall Specimen were prepared at optimum bitumen content and then tested using IPC Global Universal Testing Machine (UTM), in order to investigate the creep stiffness of both modified and control mix. From the results obtained it was found that 1% and 2% PP modified bituminous mix offer better results in comparison to control and 3% PP modified mix samples. The results verify all the findings of empirical and viscosity test results which indicates that polymer modification induces stiffening effect in the binder. Enhanced viscous component of the binder was considered responsible for this change which eventually enhances the mechanical strength of the modified bituminous mixes.

Keywords: polymer modified bitumen, stiffness, creep, viscosity

Procedia PDF Downloads 419
10707 Research Developments in Vibration Control of Structure Using Tuned Liquid Column Dampers: A State-of-the-Art Review

Authors: Jay Gohel, Anant Parghi

Abstract:

A tuned liquid column damper (TLCD) is a modified passive system of tuned mass damper, where a liquid is used in place of mass in the structure. A TLCD consists of U-shaped tube with an orifice that produces damping against the liquid motion in the tube. This paper provides a state-of-the-art review on the vibration control of wind and earthquake excited structures using liquid dampers. Further, the paper will also discuss the theoretical background of TCLD, history of liquid dampers and existing literature on experimental, numerical, and analytical study. The review will also include different configuration of TLCD viz single TLCD, multi tuned liquid column damper (MTLCD), TLCD-Interior (TLCDI), tuned liquid column ball damper (TLCBD), tuned liquid column ball gas damper (TLCBGD), and pendulum liquid column damper (PLCD). The dynamic characteristics of the different configurate TLCD system and their effectiveness in reducing the vibration of structure will be discussed. The effectiveness of semi-active TLCD will be also discussed with reference to experimental and analytical results. In addition, the review will also provide the numerous examples of implemented TLCD to control the vibration in real structures. Based on the comprehensive review of literature, some important conclusions will be made and the need for future research will be identified for vibration control of structures using TLCD.

Keywords: earthquake, wind, tuned liquid column damper, passive response control, structures

Procedia PDF Downloads 208
10706 Carbohydrate Intake Estimation in Type I Diabetic Patients Described by UVA/Padova Model

Authors: David A. Padilla, Rodolfo Villamizar

Abstract:

In recent years, closed loop control strategies have been developed in order to establish a healthy glucose profile in type 1 diabetic mellitus (T1DM) patients. However, the controller itself is unable to define a suitable reference trajectory for glucose. In this paper, a control strategy Is proposed where the shape of the reference trajectory is generated bases in the amount of carbohydrates present during the digestive process, due to the effect of carbohydrate intake. Since there no exists a sensor to measure the amount of carbohydrates consumed, an estimator is proposed. Thus this paper presents the entire process of designing a carbohydrate estimator, which allows estimate disturbance for a predictive controller (MPC) in a T1MD patient, the estimation will be used to establish a profile of reference and improve the response of the controller by providing the estimated information of ingested carbohydrates. The dynamics of the diabetic model used are due to the equations described by the UVA/Padova model of the T1DMS simulator, the system was developed and simulated in Simulink, taking into account the noise and limitations of the glucose control system actuators.

Keywords: estimation, glucose control, predictive controller, MPC, UVA/Padova

Procedia PDF Downloads 261
10705 Identifying Necessary Words for Understanding Academic Articles in English as a Second or a Foreign Language

Authors: Stephen Wagman

Abstract:

This paper identifies three common structures in English sentences that are important for understanding academic texts, regardless of the characteristics or background of the readers or whether they are reading English as a second or a foreign language. Adapting a model from the Humanities, the explication of texts used in literary studies, the paper analyses sample sentences to reveal structures that enable the reader not only to decide which words are necessary for understanding the main ideas but to make the decision without knowing the meaning of the words. By their very syntax noun structures point to the key word for understanding them. As a rule, the key noun is followed by easily identifiable prepositions, relative pronouns, or verbs and preceded by single adjectives. With few exceptions, the modifiers are unnecessary for understanding the idea of the sentence. In addition, sentences are often structured by lists in which the items frequently consist of parallel groups of words. The principle of a list is that all the items are similar in meaning and it is not necessary to understand all of the items to understand the point of the list. This principle is especially important when the items are long or there is more than one list in the same sentence. The similarity in meaning of these items enables readers to reduce sentences that are hard to grasp to an understandable core without excessive use of a dictionary. Finally, the idea of subordination and the identification of the subordinate parts of sentences through connecting words makes it possible for readers to focus on main ideas without having to sift through the less important and more numerous secondary structures. Sometimes a main idea requires a subordinate one to complete its meaning, but usually, subordinate ideas are unnecessary for understanding the main point of the sentence and its part in the development of the argument from sentence to sentence. Moreover, the connecting words themselves indicate the functions of the subordinate structures. These most frequently show similarity and difference or reasons and results. Recognition of all of these structures can not only enable students to read more efficiently but to focus their attention on the development of the argument and this rather than a multitude of unknown vocabulary items, the repetition in lists, or the subordination in sentences are the one necessary element for comprehension of academic articles.

Keywords: development of the argument, lists, noun structures, subordination

Procedia PDF Downloads 246
10704 Impact of innovative Solar Heating Systems on Greenhouse ‎Microclimates: A Case Study with Zucchini (Cucurbita pepo)‎

Authors: Ilham Ihoume, Rachid Tadili, Nora Arbaoui

Abstract:

Recent innovations in economical heating systems have significantly boosted ‎agricultural production by effectively managing temperature drops in greenhouse ‎microclimates. These advancements enhance product profitability in terms of quality, ‎quantity, and growth duration. This study experimentally investigates the impact of a ‎solar heating system on the microclimate of an agricultural greenhouse, focusing on ‎zucchini (Cucurbita pepo). The System comprises a copper tube placed between double ‎roof glazing and a sensible heat storage system, converting solar energy during the day ‎and storing it for night-time release. A second control greenhouse without heating ‎allows for comparative analysis at various growth stages. During the cold season, the ‎experimental greenhouse showed a temperature increase of 3°C compared to the ‎control greenhouse and 5°C above external ambient air. The relative humidity in the ‎experimental greenhouse ranged from 69% to 70%, whereas the control greenhouse recorded 68% to 86%, and ambient air ‎was between 94% to 99%. The heating systems achieved an efficiency of 73%, and ‎zucchini plants in the experimental greenhouse developed fruit 13 days earlier than ‎those in the control greenhouse.‎

Keywords: solar energy, storage, energy managment, heating system

Procedia PDF Downloads 44
10703 A Robust Model Predictive Control for a Photovoltaic Pumping System Subject to Actuator Saturation Nonlinearity and Parameter Uncertainties: A Linear Matrix Inequality Approach

Authors: Sofiane Bououden, Ilyes Boulkaibet

Abstract:

In this paper, a robust model predictive controller (RMPC) for uncertain nonlinear system under actuator saturation is designed to control a DC-DC buck converter in PV pumping application, where this system is subject to actuator saturation and parameter uncertainties. The considered nonlinear system contains a linear constant part perturbed by an additive state-dependent nonlinear term. Based on the saturating actuator property, an appropriate linear feedback control law is constructed and used to minimize an infinite horizon cost function within the framework of linear matrix inequalities. The proposed approach has successfully provided a solution to the optimization problem that can stabilize the nonlinear plants. Furthermore, sufficient conditions for the existence of the proposed controller guarantee the robust stability of the system in the presence of polytypic uncertainties. In addition, the simulation results have demonstrated the efficiency of the proposed control scheme.

Keywords: PV pumping system, DC-DC buck converter, robust model predictive controller, nonlinear system, actuator saturation, linear matrix inequality

Procedia PDF Downloads 181
10702 Tokyo Skyscrapers: Technologically Advanced Structures in Seismic Areas

Authors: J. Szolomicki, H. Golasz-Szolomicka

Abstract:

The architectural and structural analysis of selected high-rise buildings in Tokyo is presented in this paper. The capital of Japan is the most densely populated city in the world and moreover is located in one of the most active seismic zones. The combination of these factors has resulted in the creation of sophisticated designs and innovative engineering solutions, especially in the field of design and construction of high-rise buildings. The foreign architectural studios (as, for Jean Nouvel, Kohn Pedesen Associates, Skidmore, Owings & Merill) which specialize in the designing of skyscrapers, played a major role in the development of technological ideas and architectural forms for such extraordinary engineering structures. Among the projects completed by them, there are examples of high-rise buildings that set precedents for future development. An essential aspect which influences the design of high-rise buildings is the necessity to take into consideration their dynamic reaction to earthquakes and counteracting wind vortices. The need to control motions of these buildings, induced by the force coming from earthquakes and wind, led to the development of various methods and devices for dissipating energy which occur during such phenomena. Currently, Japan is a global leader in seismic technologies which safeguard seismic influence on high-rise structures. Due to these achievements the most modern skyscrapers in Tokyo are able to withstand earthquakes with a magnitude of over seven degrees at the Richter scale. Damping devices applied are of a passive, which do not require additional power supply or active one which suppresses the reaction with the input of extra energy. In recent years also hybrid dampers were used, with an additional active element to improve the efficiency of passive damping.

Keywords: core structures, damping system, high-rise building, seismic zone

Procedia PDF Downloads 175
10701 Active Control Improvement of Smart Cantilever Beam by Piezoelectric Materials and On-Line Differential Artificial Neural Networks

Authors: P. Karimi, A. H. Khedmati Bazkiaei

Abstract:

The main goal of this study is to test differential neural network as a controller of smart structure and is to enumerate its advantages and disadvantages in comparison with other controllers. In this study, the smart structure has been considered as a Euler Bernoulli cantilever beam and it has been tried that it be under control with the use of vibration neural network resulting from movement. Also, a linear observer has been considered as a reference controller and has been compared its results. The considered vibration charts and the controlled state have been recounted in the final part of this text. The obtained result show that neural observer has better performance in comparison to the implemented linear observer.

Keywords: smart material, on-line differential artificial neural network, active control, finite element method

Procedia PDF Downloads 210
10700 Control Performance Simulation and Analysis for Microgravity Vibration Isolation System Onboard Chinese Space Station

Authors: Wei Liu, Shuquan Wang, Yang Gao

Abstract:

Microgravity Science Experiment Rack (MSER) will be onboard TianHe (TH) spacecraft planned to be launched in 2018. TH is one module of Chinese Space Station. Microgravity Vibration Isolation System (MVIS), which is MSER’s core part, is used to isolate disturbance from TH and provide high-level microgravity for science experiment payload. MVIS is two stage vibration isolation system, consisting of Follow Unit (FU) and Experiment Support Unit (ESU). FU is linked to MSER by umbilical cables, and ESU suspends within FU and without physical connection. The FU’s position and attitude relative to TH is measured by binocular vision measuring system, and the acceleration and angular velocity is measured by accelerometers and gyroscopes. Air-jet thrusters are used to generate force and moment to control FU’s motion. Measurement module on ESU contains a set of Position-Sense-Detectors (PSD) sensing the ESU’s position and attitude relative to FU, accelerometers and gyroscopes sensing ESU’s acceleration and angular velocity. Electro-magnetic actuators are used to control ESU’s motion. Firstly, the linearized equations of FU’s motion relative to TH and ESU’s motion relative to FU are derived, laying the foundation for control system design and simulation analysis. Subsequently, two control schemes are proposed. One control scheme is that ESU tracks FU and FU tracks TH, shorten as E-F-T. The other one is that FU tracks ESU and ESU tracks TH, shorten as F-E-T. In addition, motion spaces are constrained within ±15 mm、±2° between FU and ESU, and within ±300 mm between FU and TH or between ESU and TH. A Proportional-Integrate-Differentiate (PID) controller is designed to control FU’s position and attitude. ESU’s controller includes an acceleration feedback loop and a relative position feedback loop. A Proportional-Integrate (PI) controller is designed in the acceleration feedback loop to reduce the ESU’s acceleration level, and a PID controller in the relative position feedback loop is used to avoid collision. Finally, simulations of E-F-T and F-E-T are performed considering variety uncertainties, disturbances and motion space constrains. The simulation results of E-T-H showed that control performance was from 0 to -20 dB for vibration frequency from 0.01 to 0.1 Hz, and vibration was attenuated 40 dB per ten octave above 0.1Hz. The simulation results of T-E-H showed that vibration was attenuated 20 dB per ten octave at the beginning of 0.01Hz.

Keywords: microgravity science experiment rack, microgravity vibration isolation system, PID control, vibration isolation performance

Procedia PDF Downloads 160
10699 Some Results on Cluster Synchronization

Authors: Shahed Vahedi, Mohd Salmi Md Noorani

Abstract:

This paper investigates cluster synchronization phenomena between community networks. We focus on the situation where a variety of dynamics occur in the clusters. In particular, we show that different synchronization states simultaneously occur between the networks. The controller is designed having an adaptive control gain, and theoretical results are derived via Lyapunov stability. Simulations on well-known dynamical systems are provided to elucidate our results.

Keywords: cluster synchronization, adaptive control, community network, simulation

Procedia PDF Downloads 475
10698 Auction Theory In Competitive Takeovers: Ideas For Regulators

Authors: Emanuele Peggi

Abstract:

The regulation of competitive takeover bids is one of the most problematic issues of any legislation on takeovers since it concerns a particular type of market, that of corporate control, whose peculiar characteristic is that companies represent "assets" unique of their kind, for each of which there will be a relevant market characterized by the presence of different subjects interested in acquiring control. Firstly, this work aims to analyze, from a comparative point of view, the regulation of takeover bids in competitive scenarios, characterized by the presence of multiple takeover bids for the same target company, and contribute to the debate on the impact that various solutions adopted in some legal systems examined (Italy, UK, and USA) have had on the efficiency of the market for corporate control. Secondly, the different auction models identified by the economic literature and their possible applications to corporate acquisitions in competitive scenarios will be examined, as well as the consequences that the application of each of them causes on the efficiency of the market for corporate control and the interests of the target shareholders. The scope is to study the possibility of attributing to the management of the target company the power to design the auction in order to better protect the interests of shareholders through the adoption of ad hoc models according to the specific context. and in particular on the ground of their assessment of the buyer's risk profile.

Keywords: takeovers, auction theory, shareholders, target company

Procedia PDF Downloads 175
10697 Preparation and Quality Control of a New Radiolabelled Complex of Spion

Authors: H. Yousefnia, SJ. Ahmadi, S. Sajadi, S. Zolghadri, A. Bahrami-Samani, M. Bagherzadeh

Abstract:

Nowadays, superparamagnetic iron oxide nanoparticles (SPIONs) as the multitask agents have showed advantageous characteristics. The aim of this study was the preparation and quality control of 153Sm-DTPA-DA-SPION complex. Samarium-153 was produced by neutron irradiation of the enriched 152Sm2O3 in a research reactor for 5 d. For radiolabeling purposes, 8 mg of the ligand was added to the vial containing 153SmCl3 and the mixture was sonicated 30 min, while pH was adjusted to 7-8. The radiochemical purity of the complex was checked by the ITLC method using NH4OH:MeOH:H2O (0.2:2:4) as the mobile phase. This new radiolabeled complex was prepared with a radiochemical purity of higher than 98% in 30 min at the optimized condition. The complex was kept at room temperature and in human serum at 37 °C for 48 h, showed no loss of 153Sm from the complex. Considering all of these features, this new radiolabeled complex can be considered as a good therapeutic agent; however, further studies on its biological behavior are still needed.

Keywords: iron nanoparticles, preparation, quality control, 153Sm

Procedia PDF Downloads 330
10696 Evaluation of Phonophoresis with Dexamethasone in Treatment of Hypertrophic Burn Scar

Authors: Alireza Pishgahi, Mohammad Rahbar, Javad Shokri, Shahla Dareshiri, Yaghoub Salekzamani, Fariba Eslamian

Abstract:

Background and Objectives: Hypertrophic scars are one of the complications following a burn injury. Intralesional corticosteroid injection is an invasive method for treatment of this complication. We had design a single blinded randomized control trial to deliver dexamethasone by phonophoresis and evaluate its efficacy on hypertrophic burn scars characteristics. Material and Methods: 56 cases of hypertrophic burn scar due to burn injury allocated randomly to dexamethasone and control group. Individuals in case group received 10 sessions of dexamethasone 0.4% phonophoresis. Patients in control group had placebo phonophoresis (ultrasound with normal routine aquatic gel without any dexamethasone) with the same protocol. At the beginning of study and one week after last session, hypertrophic scar characteristics and pruritus were measured by ‘Vancouver Scar Scale’, and ‘5-D Pruritus Scale’ respectively in both groups. Results: Despite mild improvement in Vancouver Scar Scale score one week after intervention in dexamethasone phonophoresis group in comparison to control subjects, but this difference was not significant (p=0.08). Pruritus score perceived subjectively were significantly lower one week after intervention in dexamethasone groups in comparison to control subjects (p=0.00). Conclusion: Dexamethasone phonophoresis is a safe and effective treatment method for burn hypertrophic scar pruritus, but its efficacy for scar characteristics improvement needs to be evaluated by larger studies with long-term follow-up period.

Keywords: dexamethasone, hypertrophic scar, phonophoresis, pruritus

Procedia PDF Downloads 173
10695 Linear Parameter-Varying Control for Selective Catalytic Reduction Systems

Authors: Jihoon Lim, Patrick Kirchen, Ryozo Nagamune

Abstract:

This paper proposes a linear parameter-varying (LPV) controller capable of reducing nitrogen oxide (NOx) emissions with low ammonia (NH3) slip downstream of selective catalytic reduction (SCR) systems. SCR systems are widely adopted in diesel engines due to high NOx conversion efficiency. However, the nonlinearity of the SCR system and sensor uncertainty result in a challenging control problem. In order to overcome the control challenges, an LPV controller is proposed based on gain-scheduling parameters, that is, exhaust gas temperature and exhaust gas flow rate. Based on experimentally obtained data under the non-road transient driving cycle (NRTC), the simulations firstly show that the proposed controller yields high NOx conversion efficiency with a desired low NH3 slip. The performance of the proposed LPV controller is then compared with other controllers, including a gain-scheduling PID controller and a sliding mode controller. Additionally, the robustness is also demonstrated using the uncertainties ranging from 10 to 30%. The results show that the proposed controller is robustly stable under uncertainties.

Keywords: diesel engine, gain-scheduling control, linear parameter-varying, selective catalytic reduction

Procedia PDF Downloads 146
10694 The Effects of Parent Psycho-Education Program on Problem-Solving Skills of Parents

Authors: Tuba Bagatarhan, Digdem Muge Siyez

Abstract:

The aim of this research is to examine the effects of the psycho-education program on problem-solving skills of parents of high school students in the risk group for Internet addiction. A quasi-experimental design based on the pre-test, post-test and follow up test including experimental and control groups was used in the research. The independent variable of the study was the parent psycho-education program on problem-solving skills; the dependent variable was the problem-solving skills of parents. The research was conducted with the parents of 52 tenth-grade students in the risk group for Internet addiction from two high schools and volunteer to participate research on evaluation of the effectiveness of internet addiction prevention psycho-education program within the scope of another study. In this study, as 26 students were in the experimental groups in the first-high school, the parents of these 26 students were asked if they would like to participate in the parent psycho-education program on parental problem-solving skills. The parents were volunteer to participate in parent psycho-education program assigned experimental group (n=13), the other parents assigned control group 1 (n=13) in the first high school. The parents of the 26 students were randomly assigned to the control group 2 (n=13) and control group 3 (n=13) in the second high school. The data of the research was obtained via the problem behavior scale - coping - parents form and demographic questionnaire. Four-session parent psycho-education program to cope with Internet addiction and other problem behaviors in their children was applied to the experimental group. No program was applied to the control group 1, control group 2 and control group 3. In addition, an internet addiction prevention psycho-education program was applied to the children of the parents in experimental group and control group 1 within the scope of another study. In the analysis of the obtained data, two-factor variance analysis for repeated measures on one factor was used. Bonferroni post-hoc test was used to find the source of intergroup difference. According to the findings, the psycho-education program significantly increases parents’ problem-solving abilities, and the increase has continued throughout the follow-up test.

Keywords: internet addiction, parents, prevention, psyho-education

Procedia PDF Downloads 182
10693 DEM Simulation of the Formation of Seed Granules in Twin-Screw Granulation Process

Authors: Tony Bediako Arthur, Nejat Rahmanian, Nana Gyan Sekyi

Abstract:

The possibility of producing seeded granules from fine and course powders is a major challenge as the control parameters that affect its producibility is still under investigation. The seeded granulation is a novel form of producing granules where the granule is made up of larger particles at the core, which are surrounded by fine particles. The possibility of managing granulation through course particle feed rate control makes seeded granulation in continuous granulation useful in terms of process control. Twin screw granulation is now a major process of choice for the wet continuous granulation process in the industry. It is, therefore, imperative to investigate the process control parameters that influence the formation of seeded granules in twin screw granulation. In this paper, the effect of the twin screws rotating speed on the production of seeded granules has been examined. Pictorial and quantitative analysis indicates a high number of seeded granules forming at low screw rotating speeds. It is also instructive to say that higher tensile stress occurs at the kneading section of the screws; thus, higher rotating speed courses the fines for breaking off from the seed particle.

Keywords: DEM, twin-screw, Seeded granules, Simulation

Procedia PDF Downloads 88
10692 Seismic Response Control of Multi-Span Bridge Using Magnetorheological Dampers

Authors: B. Neethu, Diptesh Das

Abstract:

The present study investigates the performance of a semi-active controller using magneto-rheological dampers (MR) for seismic response reduction of a multi-span bridge. The application of structural control to the structures during earthquake excitation involves numerous challenges such as proper formulation and selection of the control strategy, mathematical modeling of the system, uncertainty in system parameters and noisy measurements. These problems, however, need to be tackled in order to design and develop controllers which will efficiently perform in such complex systems. A control algorithm, which can accommodate un-certainty and imprecision compared to all the other algorithms mentioned so far, due to its inherent robustness and ability to cope with the parameter uncertainties and imprecisions, is the sliding mode algorithm. A sliding mode control algorithm is adopted in the present study due to its inherent stability and distinguished robustness to system parameter variation and external disturbances. In general a semi-active control scheme using an MR damper requires two nested controllers: (i) an overall system controller, which derives the control force required to be applied to the structure and (ii) an MR damper voltage controller which determines the voltage required to be supplied to the damper in order to generate the desired control force. In the present study a sliding mode algorithm is used to determine the desired optimal force. The function of the voltage controller is to command the damper to produce the desired force. The clipped optimal algorithm is used to find the command voltage supplied to the MR damper which is regulated by a semi active control law based on sliding mode algorithm. The main objective of the study is to propose a robust semi active control which can effectively control the responses of the bridge under real earthquake ground motions. Lumped mass model of the bridge is developed and time history analysis is carried out by solving the governing equations of motion in the state space form. The effectiveness of MR dampers is studied by analytical simulations by subjecting the bridge to real earthquake records. In this regard, it may also be noted that the performance of controllers depends, to a great extent, on the characteristics of the input ground motions. Therefore, in order to study the robustness of the controller in the present study, the performance of the controllers have been investigated for fourteen different earthquake ground motion records. The earthquakes are chosen in such a way that all possible characteristic variations can be accommodated. Out of these fourteen earthquakes, seven are near-field and seven are far-field. Also, these earthquakes are divided into different frequency contents, viz, low-frequency, medium-frequency, and high-frequency earthquakes. The responses of the controlled bridge are compared with the responses of the corresponding uncontrolled bridge (i.e., the bridge without any control devices). The results of the numerical study show that the sliding mode based semi-active control strategy can substantially reduce the seismic responses of the bridge showing a stable and robust performance for all the earthquakes.

Keywords: bridge, semi active control, sliding mode control, MR damper

Procedia PDF Downloads 124
10691 The Correlation between Emotional Intelligence and Locus of Control: Empirical Study on Lithuanian Youth

Authors: Dalia Antiniene, Rosita Lekaviciene

Abstract:

The qualitative methodology based study is designed to reveal a connection between emotional intelligence (EI) and locus of control (LC) within the population of Lithuanian youth. In the context of emotional problems, the locus of control reflects how one estimates the causes of his/her emotions: internals (internal locus of control) associate their emotions with their manner of thinking, whereas externals (external locus of control) consider emotions to be evoked by external circumstances. On the other hand, there is little empirical data about this connection, and the results in disposition are often contradictory. In the conducted study 1430 young people, aged 17 to 27, from various regions of Lithuania were surveyed. The subjects were selected by quota sampling, maintaining natural proportions of the general Lithuanian youth population. To assess emotional intelligence the EI-DARL test (i.e. self-report questionnaire consisting of 75 items) was implemented. The emotional intelligence test, created applying exploratory factor analysis, reveals four main dimensions of EI: understanding of one’s own emotions, regulation of one’s own emotions, understanding other’s emotions, and regulation of other’s emotions (subscale reliability coefficients fluctuate between 0,84 and 0,91). An original 16-item internality/externality scale was used to examine the locus of control (internal consistency of the Externality subscale - 0,75; Internality subscale - 0,65). The study has determined that the youth understands and regulates other people’s emotions better than their own. Using the K-mean cluster analysis method, it was established that there are three groups of subjects according to their EI level – people with low, medium and high EI. After comparing means of subjects’ favorability of statements on the Internality/Externality scale, a predominance of internal locus of control in the young population was established. The multiple regression models has shown that a rather strong statistically significant correlation exists between total EI, EI subscales and LC. People who tend to attribute responsibility for the outcome of their actions to their own abilities and efforts have higher EI and, conversely, the tendency to attribute responsibility to external forces is related more with lower EI. While pursuing their goals, young people with high internality have a predisposition to analyze perceived emotions and, therefore, gain emotional experience: they learn to control their natural reactions and to act adequately in a situation at hand. Thus the study unfolds, that a person’s locus of control and emotional intelligence are related phenomena and allows us to draw a conclusion, that a person’s internality/externality is a reliable predictor of total EI and its components.

Keywords: emotional intelligence, externality, internality, locus of control

Procedia PDF Downloads 222
10690 Metabolic Syndrome and Mental Health in Post Traumatic Stress Disorder Patient

Authors: Hassan Shahmiri Barzoki

Abstract:

Background: Posttraumatic stress disorder (PTSD) is an abnormal physiologic and psychological reaction in person with severe traumatic history. In recent studies, the relationship between PTSD and some other disease apparently unrelated to psychological situations, such as cardiovascular diseases, diabetes, and metabolic syndrome, has been revealed. Thus, the aim of this study was to survey the prevalence of metabolic syndrome and mental health in PTSD patients. Methods: The research design was retrospective cohort study. Subjects were consisted of 142 Iran-Iraq war veterans with PTSD (age: 40-60 years), and the control group was consisted of 153 veterans without PTSD. Data was collected using questionnaires, physical exams and laboratory tests. Results: Prevalence of metabolic syndrome was 45.1%in PTSD group and 17% in control group. In addition, blood pressure, triglyceride and fasting blood sugar in PTSD group were significantly higher than control group (p<0.05). Also, PTSD patients had significant high rates of psychiatric disorders. Conclusion: PTSD patients are more prone to metabolic syndrome and psychiatric disorders than control group.

Keywords: mental health, metabolic syndrome, post traumatic stress disorder, patient

Procedia PDF Downloads 93
10689 Cost Analysis of Neglected Tropical Disease in Nigeria: Implication for Programme Control and Elimination

Authors: Lawong Damian Bernsah

Abstract:

Neglected Tropical Diseases (NTDs) are most predominant among the poor and rural populations and are endemic in 149 countries. These diseases are the most prevalent and responsible for infecting 1.4 billion people worldwide. There are 17 neglected tropical diseases recognized by WHO that constitute the fourth largest disease health and economic burden of all communicable diseases. Five of these 17 diseases are considered for the cost analysis of this paper: lymphatic filariasis, onchocerciasis, trachoma, schistosomiasis, and soil transmitted helminth infections. WHO has proposed a roadmap for eradication and elimination by 2020 and treatments have been donated through the London Declaration by pharmaceutical manufacturers. The paper estimates the cost of NTD control programme and elimination for each NTD disease and total in Nigeria. This is necessary as it forms the bases upon which programme budget and expenditure could be based. Again, given the opportunity cost the resources for NTD face it is necessary to estimate the cost so as to provide bases for comparison. Cost of NTDs control and elimination programme is estimated using the population at risk for each NTD diseases and for the total. The population at risk is gotten from the national master plan for the 2015 - 2020, while the cost per person was gotten for similar studies conducted in similar settings and ranges from US$0.1 to US$0.5 for Mass Administration of Medicine (MAM) and between US$1 to US$1.5 for each NTD disease. The combined cost for all the NTDs was estimated to be US$634.88 million for the period 2015-2020 and US$1.9 billion for each NTD disease for the same period. For the purpose of sensitivity analysis and for robustness of the analysis the cost per person was varied and all were still high. Given that health expenditure for Nigeria (% of GDP) averages 3.5% for the period 1995-2014, it is very clear that efforts have to be made to improve allocation to the health sector in general which is hoped could trickle to NTDs control and elimination. Thus, the government and the donor partners would need to step-up budgetary allocation and also to be aware of the costs of NTD control and elimination programme since they have alternative uses. Key Words: Neglected Tropical Disease, Cost Analysis, NTD Programme Control and Elimination, Cost per Person

Keywords: Neglected Tropical Disease, Cost Analysis, Neglected Tropical Disease Programme Control and Elimination, Cost per Person

Procedia PDF Downloads 273
10688 Coordinated Voltage Control in Radial Distribution System with Distributed Generators Using Sensitivity Analysis

Authors: Anubhav Shrivastava Shivarudraswamy, Bhat Lakshya

Abstract:

Distributed generation has indeed become a major area of interest in recent years. Distributed generation can address a large number of loads in a power line and hence has better efficiency over the conventional methods. However, there are certain drawbacks associated with it, an increase in voltage being the major one. This paper addresses the voltage control at the buses for an IEEE 30 bus system by regulating reactive power. For carrying out the analysis, the suitable location for placing distributed generators (DG) is identified through load flow analysis and seeing where the voltage profile is dipping. MATLAB programming is used to regulate the voltage at all buses within +/- 5% of the base value even after the introduction of DGs. Three methods for regulation of voltage are discussed. A sensitivity based analysis is then carried out to determine the priority among the various methods listed in the paper.

Keywords: distributed generators, distributed system, reactive power, voltage control, sensitivity analysis

Procedia PDF Downloads 659
10687 Optimal Control of Generators and Series Compensators within Multi-Space-Time Frame

Authors: Qian Chen, Lin Xu, Ping Ju, Zhuoran Li, Yiping Yu, Yuqing Jin

Abstract:

The operation of power grid is becoming more and more complex and difficult due to its rapid development towards high voltage, long distance, and large capacity. For instance, many large-scale wind farms have connected to power grid, where their fluctuation and randomness is very likely to affect the stability and safety of the grid. Fortunately, many new-type equipments based on power electronics have been applied to power grid, such as UPFC (Unified Power Flow Controller), TCSC (Thyristor Controlled Series Compensation), STATCOM (Static Synchronous Compensator) and so on, which can help to deal with the problem above. Compared with traditional equipment such as generator, new-type controllable devices, represented by the FACTS (Flexible AC Transmission System), have more accurate control ability and respond faster. But they are too expensive to use widely. Therefore, on the basis of the comparison and analysis of the controlling characteristics between traditional control equipment and new-type controllable equipment in both time and space scale, a coordinated optimizing control method within mutil-time-space frame is proposed in this paper to bring both kinds of advantages into play, which can better both control ability and economical efficiency. Firstly, the coordination of different space sizes of grid is studied focused on the fluctuation caused by large-scale wind farms connected to power grid. With generator, FSC (Fixed Series Compensation) and TCSC, the coordination method on two-layer regional power grid vs. its sub grid is studied in detail. The coordination control model is built, the corresponding scheme is promoted, and the conclusion is verified by simulation. By analysis, interface power flow can be controlled by generator and the specific line power flow between two-layer regions can be adjusted by FSC and TCSC. The smaller the interface power flow adjusted by generator, the bigger the control margin of TCSC, instead, the total consumption of generator is much higher. Secondly, the coordination of different time sizes is studied to further the amount of the total consumption of generator and the control margin of TCSC, where the minimum control cost can be acquired. The coordination method on two-layer ultra short-term correction vs. AGC (Automatic Generation Control) is studied with generator, FSC and TCSC. The optimal control model is founded, genetic algorithm is selected to solve the problem, and the conclusion is verified by simulation. Finally, the aforementioned method within multi-time-space scale is analyzed with practical cases, and simulated on PSASP (Power System Analysis Software Package) platform. The correctness and effectiveness are verified by the simulation result. Moreover, this coordinated optimizing control method can contribute to the decrease of control cost and will provide reference to the following studies in this field.

Keywords: FACTS, multi-space-time frame, optimal control, TCSC

Procedia PDF Downloads 267
10686 Optimizing and Evaluating Performance Quality Control of the Production Process of Disposable Essentials Using Approach Vague Goal Programming

Authors: Hadi Gholizadeh, Ali Tajdin

Abstract:

To have effective production planning, it is necessary to control the quality of processes. This paper aims at improving the performance of the disposable essentials process using statistical quality control and goal programming in a vague environment. That is expressed uncertainty because there is always a measurement error in the real world. Therefore, in this study, the conditions are examined in a vague environment that is a distance-based environment. The disposable essentials process in Kach Company was studied. Statistical control tools were used to characterize the existing process for four factor responses including the average of disposable glasses’ weights, heights, crater diameters, and volumes. Goal programming was then utilized to find the combination of optimal factors setting in a vague environment which is measured to apply uncertainty of the initial information when some of the parameters of the models are vague; also, the fuzzy regression model is used to predict the responses of the four described factors. Optimization results show that the process capability index values for disposable glasses’ average of weights, heights, crater diameters and volumes were improved. Such increasing the quality of the products and reducing the waste, which will reduce the cost of the finished product, and ultimately will bring customer satisfaction, and this satisfaction, will mean increased sales.

Keywords: goal programming, quality control, vague environment, disposable glasses’ optimization, fuzzy regression

Procedia PDF Downloads 223
10685 Differentiation of the Functional in an Optimization Problem for Coefficients of Elliptic Equations with Unbounded Nonlinearity

Authors: Aigul Manapova

Abstract:

We consider an optimal control problem in the higher coefficient of nonlinear equations with a divergent elliptic operator and unbounded nonlinearity, and the Dirichlet boundary condition. The conditions imposed on the coefficients of the state equation are assumed to hold only in a small neighborhood of the exact solution to the original problem. This assumption suggests that the state equation involves nonlinearities of unlimited growth and considerably expands the class of admissible functions as solutions of the state equation. We obtain formulas for the first partial derivatives of the objective functional with respect to the control functions. To calculate the gradients the numerical solutions of the state and adjoint problems are used. We also prove that the gradient of the cost function is Lipchitz continuous.

Keywords: cost functional, differentiability, divergent elliptic operator, optimal control, unbounded nonlinearity

Procedia PDF Downloads 172
10684 Recent Legal Changes in Turkish Commercial Law to Be a Part of International Markets and Their Results

Authors: Ibrahim Arslan

Abstract:

Since 1984, Turkey has experienced a significant transformation in legal and economic matters. The most consequential examples of this transformation in recent years are the renewal of the Commercial Code and the Check Act. Nowadays, the commercial activity is not limited within the boundaries of the country; on the contrary, as required by the global economy, it has an international dimension. For this reason, unlike some other legal principles, the rules regulating the commercial life should be compatible with the international standards as much as possible. Otherwise the development possibility in the global markets will be limited. The Check Act has been adopted in 2009 and the Commercial Code has been adopted in 2011. The Commercial Code has been entered into force on 1 July 2012. The international dimension of check is in-disputable for it is based on the Geneva Convention. However, the Turkish business life has created a unique application of this legal tool. This application is called “post-date” checks. Indeed the majority of the checks being used in the market are post-dated checks. The holders of these checks have waited the date written on the check for presentation and collection. Thus, the actual situation has occurred. This actual situation has been legitimized via Check Act No. 5941 and post dated checks have gained a legal status. In the preparation of the new the Turkish Commercial Code one of the goals is "to ensure that the Turkish commercial law becomes a part of the international market". To achieve this goal, significant changes have been made especially concerning the independent external audition of the corporations, the board structure and public disclosure regulations. These changes aim to facilitate the internationalization of Turkish corporations as well as intensification of foreign direct investments through foreign capital. Although the target has been determined this way, after the adoption but five days before the entry into force of the Turkish Commercial Code No. 6102, a law made backward going alterations concerning independent external audition and public disclosure regulations. Turkish Commercial Code has been currently in force with its altered status. Both the regulations in the Check Act as well as the changes in the Commercial Code are not compatible with the goals introduced by rationale “to ensure Turkish commercial law to be a part of the international market” as such.

Keywords: Turkish Commercial Code No. 6102, Turkish Check Act, “post-date” checks, legal changes

Procedia PDF Downloads 294