Search results for: transcranial direct current electrical stimulation
13485 Transfer of Electrical Energy by Magnetic Induction
Authors: Carlos Oliveira Santiago Filho, Ciro Egoavil, Eduardo Oliveira, Jéferson Galdino, Moises Galileu, Tiago Oliveira Correa
Abstract:
Transfer of Electrical Energy through resonant inductive magnetic coupling is demonstrated experimentally in a system containing coil primary for transmission and secondary reception. The topology used in the prototype of the Class-E amplifier, has been identified as optimal for power transfer applications. Characteristic of the inductor and the load are defined by the requirements of the resonant inductive system. The frequency limitation the of circuit restricts unloaded “Q-Factor”, quality factor of the coils and thus the link efficiency. With a suitable circuit, copper coil unloaded Q-Factors of over 1,000 can be achieved in the low Mhz region, enabling a cost-effective high Q coil assembly. The circuit is capable system capable of transmitting energy with direct current to load efficiency above 60% at 2 Mhz.Keywords: magnetic induction, transfer of electrical energy, magnetic coupling, Q-Factor
Procedia PDF Downloads 51813484 Study of the Tribological Behavior of a Sliding Contact Brass-Steel Couple with Electrical Current
Authors: C. Boubechou, A. Bouchoucha, H. Zaidi
Abstract:
The aim of this paper is to study the tribological behavior of a dynamic contact steel-brass couple with electric current. This study looks at a dry contact brass-steel couple where friction and wear are studied in terms of mechanical and electrical parameters. For this reason, a tribometer, pin-rotary disc is used in an atmospheric atmosphere. The test parameters are as follows: the normal load (5-30N), the sliding speed (0.1 to 0.5 m / s) and the electric current (3-10A). The duration of each test is 30 minutes. The experimental results show that these parameters have a significant effect on the tribological behavior of the couple studied. The discussion of results is based on observations, using an optical microscope, MEB and a profilometer, worn surfaces and interface phenomena resulting from the process of sliding contact.Keywords: brass-steel couple, dry friction, electrical current, morphology, normal load, sliding speeds, wear
Procedia PDF Downloads 26613483 Analysis of Direct Current Motor in LabVIEW
Authors: E. Ramprasath, P. Manojkumar, P. Veena
Abstract:
DC motors have been widely used in the past centuries which are proudly known as the workhorse of industrial systems until the invention of the AC induction motors which makes a huge revolution in industries. Since then, the use of DC machines have been decreased due to enormous factors such as reliability, robustness and complexity but it lost its fame due to the losses. A new methodology is proposed to construct a DC motor through the simulation in LabVIEW to get an idea about its real time performances, if a change in parameter might have bigger improvement in losses and reliability.Keywords: analysis, characteristics, direct current motor, LabVIEW software, simulation
Procedia PDF Downloads 55113482 Development of a Myocardial Patch with 3D Hydrogel Electrical Stimulation System
Authors: Yung-Gi Chen, Pei-Leun Kang, Yu-Hsin Lin, Shwu-Jen Chang
Abstract:
Myocardial tissue has limited self-repair ability due to its loss of differentiation characteristic for most mature cardiomyocytes. Therefore, the effective use of stem cell technology in regenerative medicine is an important development to alleviate the current difficulties in cardiac disease treatment. The main purpose of this project was to develop a 3-D hydrogel electrical stimulating system for promoting the differentiation of stem cells into myocardial cells, and the patch will be used to repair damaged myocardial tissue. This project was focused on the preparation of the electrical stimulation system with carbon/CaCl₂ electrodes covered with carbon nanotube-hydrogel. In this study, we utilized screen imprinting techniques and used Poly(lactic-co-glycolic acid)(PLGA) membranes as printing substrates to fabricate a carbon/CaCl₂ interdigitated electrode that covered with alginate/carbon nanotube hydrogels. The single-walled carbon nanotube was added in the hydrogel to enhance the mechanical strength and conductivity of hydrogel. In this study, we used PLGA (85:15) as electrode preparing substrate. The CaCl₂/ EtOH solution (80% w/v) was mixed into carbon paste to prepare various concentration calcium-containing carbon paste (2.5%, 5%, 7.5%, 10% v/v). Different concentrations of alginate (1%, 1.5%, 2% v/v) and SWCNT(Diameter < 2nm, length between 5-15μm) (1, 1.5, 3 mg/ml) are gently immobilized on the electrode by cross-linking with calcium chloride. The three-dimensional hydrogel electrode was tested for its redox efficiency by cyclic voltammetry to determine the optimal parameters for the hydrogel electrode preparation. From the result of the final electrodes, it indicated that the electrode was not easy to maintain the pattern of the interdigitated electrode when the concentration of calcium of chloride was more than 10%. According to the gel rate test and cyclic voltammetry experiment results showed the SWCNT could increase the electron conduction of hydrogel electrodes significantly. So far the 3D electrode system has been completed, 2% alginate mixed with 3mg SWCNT is the optimal condition to construct the most complete structure for the hydrogel preparation.Keywords: myocardial tissue engineering, screen printing technology, poly (lactic-co-glycolic acid), alginate, single walled carbon nanotube
Procedia PDF Downloads 11213481 Treatment of Oil Recovery Water Using Direct and Indirect Electrochemical Oxidation
Authors: Tareg Omar Mansour, Khaled Omar Elhaji
Abstract:
Model solutions of pentanol in the salt water of various concentrations were subjected to electrochemical oxidation using a dimensionally stable anode (DSA) and a platinised titanium cathode. The removal of pentanol was analysed over time using gas chromatography (GC) and by monitoring the total organic carbon (TOC) concentration of the reaction mixture. It was found that the removal of pentanol occurred more efficiently at higher salinities and higher applied electrical current values. When using a salt concentration of 20,000 ppm and an applied current of 100 mA there was a decrease in concentration of pentanol of 15 %. When the salt concentration and applied current were increased to 58,000 ppm and 500 mA respectively, the decrease in concentration was improved to 64 %.Keywords: dimensionally stable anode (DSA), total organic hydrocarbon (TOC), gas chromatography mass spectrometry (GCMS), electrochemical oxidation
Procedia PDF Downloads 38313480 Ovarian Stimulation and Oocyte Cryopreservation for Fertility Preservation in Adolescent Females at the Royal Children’s Hospital: A Case Series
Authors: Kira Merigan
Abstract:
BACKGROUND- Fertility preservation (FP) measures are increasingly recognised as an important consideration for children and adolescents planned to undergo potentially damaging gonadotoxic therapy. Worldwide, there are very few documented cases of FP in young females by way of ovarian stimulation and oocyte cryopreservation.AIM – To report a case series of mature oocyte cryopreservation in 5post-pubertal adolescents aged 14-17 years old, with varied medical conditions requiring gonadotoxic treatment. SETTING-These cases took place via a multidisciplinary team approach at The Royal Children’s Hospital, a large tertiary centre in Melbourne, Australia. INTERVENTION– Ovarian stimulation and oocyte collection was performed as detailed in each case. RESULTS –Across the 5 patients, 3-28 oocytes were retrieved. We report pre-treatment workup, complications, and delays to treatment. CONCLUSION- Oocyte cryopreservation may be a safe alternative to ovarian tissue cryopreservation (OTC) in the adolescent populationKeywords: fertility preservation, adolescent, ovarian stimulation, oocyte cryopreservation
Procedia PDF Downloads 16713479 Action Potential of Lateral Geniculate Neurons at Low Threshold Currents: Simulation Study
Authors: Faris Tarlochan, Siva Mahesh Tangutooru
Abstract:
Lateral Geniculate Nucleus (LGN) is the relay center in the visual pathway as it receives most of the input information from retinal ganglion cells (RGC) and sends to visual cortex. Low threshold calcium currents (IT) at the membrane are the unique indicator to characterize this firing functionality of the LGN neurons gained by the RGC input. According to the LGN functional requirements such as functional mapping of RGC to LGN, the morphologies of the LGN neurons were developed. During the neurological disorders like glaucoma, the mapping between RGC and LGN is disconnected and hence stimulating LGN electrically using deep brain electrodes can restore the functionalities of LGN. A computational model was developed for simulating the LGN neurons with three predominant morphologies, each representing different functional mapping of RGC to LGN. The firings of action potentials at LGN neuron due to IT were characterized by varying the stimulation parameters, morphological parameters and orientation. A wide range of stimulation parameters (stimulus amplitude, duration and frequency) represents the various strengths of the electrical stimulation with different morphological parameters (soma size, dendrites size and structure). The orientation (0-1800) of LGN neuron with respect to the stimulating electrode represents the angle at which the extracellular deep brain stimulation towards LGN neuron is performed. A reduced dendrite structure was used in the model using Bush–Sejnowski algorithm to decrease the computational time while conserving its input resistance and total surface area. The major finding is that an input potential of 0.4 V is required to produce the action potential in the LGN neuron which is placed at 100 µm distance from the electrode. From this study, it can be concluded that the neuroprostheses under design would need to consider the capability of inducing at least 0.4V to produce action potentials in LGN.Keywords: Lateral Geniculate Nucleus, visual cortex, finite element, glaucoma, neuroprostheses
Procedia PDF Downloads 27713478 Transient Current Investigations in Liquid Crystalline Polyurethane
Authors: Jitendra Kumar Quamara, Sohan Lal, Pushkar Raj
Abstract:
Electrical conduction behavior of liquid crystalline polyurethane (LCPU) has been investigated under transient conditions in the operating temperature range 50-220°C at various electric fields of 4.35-43.45 kV/cm. The transient currents show the hyperbolic decay character and the decay exponent ∆t (one tenth decay time) dependent on field as well as on temperature. The increase in I0/Is values (where I0 represents the current observed immediately after applying the voltage and Is represents the steady state current) and the variation of mobility at high operating temperatures shows the appearance of mesophase. The origin of transient currents has been attributed to the dipolar nature of carbonyl (C=O) groups in the main chain of LCPU and the trapping charge carriers.Keywords: electrical conduction, transient current, liquid crystalline polymers, mesophase
Procedia PDF Downloads 28013477 The Role Collagen VI Plays in Heart Failure: A Tale Untold
Authors: Summer Hassan, David Crossman
Abstract:
Myocardial fibrosis (MF) has been loosely defined as the process occurring in the pathological remodeling of the myocardium due to excessive production and deposition of extracellular matrix (ECM) proteins, including collagen. This reduces tissue compliance and accelerates progression to heart failure, as well as affecting the electrical properties of the myocytes resulting in arrhythmias. Microscopic interrogation of MF is key to understanding the molecular orchestrators of disease. It is well-established that recruitment and stimulation of myofibroblasts result in Collagen deposition and the resulting expansion in the ECM. Many types of Collagens have been identified and implicated in scarring of tissue. In a series of experiments conducted at our lab, we aim to elucidate the role collagen VI plays in the development of myocardial fibrosis and its direct impact on myocardial function. This was investigated through an animal experiment in Rats with Collagen VI knockout diseased and healthy animals as well as Collagen VI wild diseased and healthy rats. Echocardiogram assessments of these rats ensued at four-time points, followed by microscopic interrogation of the myocardium aiming to correlate the role collagen VI plays in myocardial function. Our results demonstrate a deterioration in cardiac function as represented by the ejection fraction in the knockout healthy and diseased rats. This elucidates a potential protective role that collagen-VI plays following a myocardial insult. Current work is dedicated to the microscopic characterisation of the fibrotic process in all rat groups, with the results to follow.Keywords: heart failure, myocardial fibrosis, collagen, echocardiogram, confocal microscopy
Procedia PDF Downloads 8213476 The Light-Effect in Cylindrical Quantum Wire with an Infinite Potential for the Case of Electrons: Optical Phonon Scattering
Authors: Hoang Van Ngoc, Nguyen Vu Nhan, Nguyen Quang Bau
Abstract:
The light-effect in cylindrical quantum wire with an infinite potential for the case of electrons, optical phonon scattering, is studied based on the quantum kinetic equation. The density of the direct current in a cylindrical quantum wire by a linearly polarized electromagnetic wave, a DC electric field, and an intense laser field is calculated. Analytic expressions for the density of the direct current are studied as a function of the frequency of the laser radiation field, the frequency of the linearly polarized electromagnetic wave, the temperature of system, and the size of quantum wire. The density of the direct current in cylindrical quantum wire with an infinite potential for the case of electrons – optical phonon scattering is nonlinearly dependent on the frequency of the linearly polarized electromagnetic wave. The analytic expressions are numerically evaluated and plotted for a specific quantum wire, GaAs/GaAsAl.Keywords: the light–effect, cylindrical quantum wire with an infinite potential, the density of the direct current, electrons-optical phonon scattering
Procedia PDF Downloads 34013475 Renewable Energy Interfaced Shunt Active Filter Using a Virtual Flux Direct Power Control
Authors: M. R. Bengourina, M. Rahli, L. Hassaine, S. Saadi
Abstract:
In this study, we present a control method entitled virtual flux direct power control of a grid connected photovoltaic system associated with an active power filter. The virtual flux direct control of power (VF-DPC) is employed for the calculation of reference current generation. In this technique, the switches states of inverter are selected from a table of switching based on the immediate errors between the active and reactive powers and their reference values. The objectives of this paper are the reduction of Total Harmonic Distortion (THD) of source current, compensating reactive power and injecting the maximum active power available from the PV array into the load and/or grid. MATLAB/SIMULINK simulations are provided to demonstrate the performance of the proposed approach.Keywords: shunt active power filter, VF-DPC, photovoltaic, MPPT
Procedia PDF Downloads 32313474 Single Tuned Shunt Passive Filter Based Current Harmonic Elimination of Three Phase AC-DC Converters
Authors: Mansoor Soomro
Abstract:
The evolution of power electronic equipment has been pivotal in making industrial processes productive, efficient and safe. Despite its attractive features, it has been due to nonlinear loads which make it vulnerable to power quality conditions. Harmonics is one of the power quality problem in which the harmonic frequency is integral multiple of supply frequency. Therefore, the supply voltage and supply frequency do not last within their tolerable limits. As a result, distorted current and voltage waveform may appear. Attributes of low power quality confirm that an electrical device or equipment is likely to malfunction, fail promptly or unable to operate under all applied conditions. The electrical power system is designed for delivering power reliably, namely maximizing power availability to customers. However, power quality events are largely untracked, and as a result, can take out a process as many as 20 to 30 times a year, costing utilities, customers and suppliers of load equipment, a loss of millions of dollars. The ill effects of current harmonics reduce system efficiency, cause overheating of connected equipment, result increase in electrical power and air conditioning costs. With the passage of time and the rapid growth of power electronic converters has highlighted the damages of current harmonics in the electrical power system. Therefore, it has become essential to address the bad influence of current harmonics while planning any suitable changes in the electrical installations. In this paper, an effort has been made to mitigate the effects of dominant 3rd order current harmonics. Passive filtering technique with six pulse multiplication converter has been employed to mitigate them. Since, the standards of power quality are to maintain the supply voltage and supply current within certain prescribed standard limits. For this purpose, the obtained results are validated as per specifications of IEEE 519-1992 and IEEE 519-2014 performance standards.Keywords: current harmonics, power quality, passive filters, power electronic converters
Procedia PDF Downloads 30113473 Direct Strength Method Approach for Indian Cold Formed Steel Sections with and Without Perforation for Compression Member
Authors: K. Raghu, Altafhusen P. Pinjar
Abstract:
Cold-formed steel section are extensively used in industry and many other non-industry constructions worldwide, it is relatively a new concept in India. Cold-formed steel sections have been developed as more economical building solutions to the alternative heavier hot-rolled sections in the commercial and residential markets. Cold‐formed steel (CFS) structural members are commonly manufactured with perforations to accommodate plumbing, electrical, and heating conduits in the walls and ceilings of buildings. Current design methods available to engineers for predicting the strength of CFS members with perforations are prescriptive and limited to specific perforation locations, spacing, and sizes. The Direct Strength Method (DSM), a relatively new design method for CFS members validated for members with and without perforations, predicts the ultimate strength of general CFS members with the elastic buckling properties of the member cross section. The design compression strength and flexural strength of Indian (IS 811-1987) standard sections is calculated as per North American Specification (AISI-S100 2007) and software CUFSM 4.05.Keywords: direct strength, cold formed, perforations, CUFSM
Procedia PDF Downloads 37913472 Study of Electrical Properties of An-Fl Based Organic Semiconducting Thin Film
Authors: A.G. S. Aldajani, N. Smida, M. G. Althobaiti, B. Zaidi
Abstract:
In order to exploit the good electrical properties of anthracene and the excellent properties of fluorescein, new hybrid material has been synthesized (An-Fl). Current-voltage measurements were done on a new single-layer ITO/An-FL/Al device of typically 100 nm thickness. Atypical diode behavior is observed with a turn-on voltage of 4.4 V, a dynamic resistance of 74.07 KΩ and a rectification ratio of 2.02 due to unbalanced transport. Results show also that the current-voltage characteristics present three different regimes of the power-law (J~Vᵐ) for which the conduction mechanism is well described with space-charge-limited current conduction mechanism (SCLC) with a charge carrier mobility of 2.38.10⁻⁵cm2V⁻¹S⁻¹. Moreover, the electrical transport properties of this device have been carried out using a dependent frequency study in the range (50 Hz–1.4 MHz) for different applied biases (from 0 to 6 V). At lower frequency, the σdc values increase with bias voltage rising, supporting that the mobile ion can hop successfully to its nearest vacant site. From σac and impedance measurements, the equivalent electrical circuit is evidenced, where the conductivity process is coherent with an exponential trap distribution caused by structural defects and/or chemical impurities.Keywords: semiconducting polymer, conductivity, SCLC, impedance spectroscopy
Procedia PDF Downloads 17813471 Supergrid Modeling and Operation and Control of Multi Terminal DC Grids for the Deployment of a Meshed HVDC Grid in South Asia
Authors: Farhan Beg, Raymond Moberly
Abstract:
The Indian subcontinent is facing a massive challenge with regards to energy security in member countries, to provide reliable electricity to facilitate development across various sectors of the economy and consequently achieve the developmental targets. The instability of the current precarious situation is observable in the frequent system failures and blackouts. The deployment of interconnected electricity ‘Supergrid’ designed to carry huge quanta of power across the Indian sub-continent is proposed in this paper. Besides enabling energy security in the subcontinent, it will also provide a platform for Renewable Energy Sources (RES) integration. This paper assesses the need and conditions for a Supergrid deployment and consequently proposes a meshed topology based on Voltage Source High Voltage Direct Current (VSC-HVDC) converters for the Supergrid modeling. Various control schemes for the control of voltage and power are utilized for the regulation of the network parameters. A 3 terminal Multi Terminal Direct Current (MTDC) network is used for the simulations.Keywords: super grid, wind and solar energy, high voltage direct current, electricity management, load flow analysis
Procedia PDF Downloads 42813470 Effect of Al Contents on Magnetic Domains of {100} Grains in Electrical Steels
Authors: Hyunseo Choi, Jaewan Hong, Seil Lee, Yang Mo Koo
Abstract:
Non-oriented (NO) electrical steel is one of the most important soft magnetic materials for rotating machines. Si has usually been added to electrical steels to reduce eddy current loss by increasing the electrical resistivity. Si content more than 3.5 wt% causes cracks during cold rolling due to increase of brittleness. Al also increases the electrical resistivity of the materials as much as Si. In addition, cold workability of Fe-Al is better than Fe-Si, so that Al can be added up to 6.0 wt%. However, the effect of Al contents on magnetic properties of electrical steels has not been studied in detail. Magnetic domains of {100} grains in electrical steels, ranging from 1.85 to 6.54 wt% Al, were observed by magneto-optic Kerr microscopy. Furthermore, the correlation of magnetic domains with magnetic properties was investigated. As Al contents increased, the magnetic domain size of {100} grains decreased due to lowered domain wall energy. Reorganization of magnetic domain structure became more complex as domain size decreased. Therefore, the addition of Al to electrical steel caused hysteresis loss to increase. Anomalous loss decreased and saturated after 4.68% Al.Keywords: electrical steel, magnetic domain structure, Al addition, core loss, rearrangement of domains
Procedia PDF Downloads 24313469 Effect of Transcutaneous Electrical Nerve Stimulation on Acupoints in Type 2 Diabetes Mellitus: A Blood Glucose Analysis
Authors: Asif Arsalan
Abstract:
The mortality rate of type 2 diabetes increasing day by day at an alarming rate. Changing lifestyle and environment have contributory effect in increase rate of type 2 diabetes mellitus. This study introduces a new method in physiotherapy field of treating a disease like diabetes, and gives the new way to control the diabetes without medicines.50 patients were selected on the basis of inclusion and exclusion criteria and were assigned to receive either TENS (group A) on the bilateral ST36 acupoints at a frequency of 25 Hz with intensity of 9 mA or placebo (group B) treatment for 5 minutes for 7 days. The blood glucose level was measured at both pre and post stimulation. Stimulation was given after 3 hours of food on every day regularly on stipulated time.There was significant improvement (P<0.05) in random blood sugar level of type 2 diabetes mellitus. It has been found TENS on bilateral ST36 acupoints have an effect to control plasma glucose level for type 2 diabetic mellitus patients and can be used without having any side effect. This study gives new idea to treat the type 2 diabetes conservatively with the TENS. As there are some study that TENS had been used to treat nausea, spasticity etc. condition by stimulating the acupoint but it is the very first time that TENS has been used to treat diabetes like disease. This study help the physiotherapy community to spread the physiotherapy treatment in other branches of the medical field and this gives a new identity for the physiotherapy. This also gives the benefit to patients to take a safe and cost effective treatment for the diabetes, and make the new use of TENS to treat other condition rather than pain.Keywords: acupoint, plasma glucose level, type 2 diabetic mellitus, TENS
Procedia PDF Downloads 30413468 Electrical Design Review Based on BIM-MEP Model
Authors: Michael Liu, Sen-Chou Tsai, Yu-Tang Huang, Tai-Chun Lin, Guan-Chyun Hsieh
Abstract:
This study proposes an electrical review method for mechanical, electrical, and plumbing (MEP) using building information modeling (BIM). The purpose is to reliably simplify the review work, directly evaluate the layout of electrical equipment and wiring, and calculate short-circuit current and line voltage drop based on BIM-MEP models. The study was done by MIEtech Company in collaboration with Taiwan Power Company (TPC), which is basically the unit responsible for reviewing the design of electrical appliances. This study aims to simplify the review process, reduce manual review errors, and improve the timeliness and reliability of reviews. In addition, the review system provides insight into the process and correctness of the precise integration of wiring, plumbing, and electrical equipment into the building structure, improving the safety and reliability of building electricity. In addition, it can also assist electrical engineers to use BIM to enhance the accuracy and self-detection capabilities of circuit design and improve the timeliness of the design process.Keywords: mechanical, electrical and plumbing, building information modeling, electrical review method
Procedia PDF Downloads 813467 Evaluating the Performance of Passive Direct Methanol Fuel Cell under Varying Operating and Structural Conditions
Authors: Rahul Saraswat
Abstract:
More recently, a focus has been given to replacing machined stainless steel metal flow fields with inexpensive wire mesh current collectors. The flow fields are based on simple woven wire mesh screens of various stainless steels, which are sandwiched between a thin metal plate of the same material to create a bipolar plate/flow field configuration for use in a stack. Major advantages of using stainless steel wire screens include the elimination of expensive raw materials as well as machining and/or other special fabrication costs. The objective of the project is to improve the performance of the passive direct methanol fuel cell without increasing the cost of the cell and to make it as compact and light as possible. From the literature survey, it was found that very little is done in this direction, and the following methodology was used. 1. The passive direct methanol fuel cell (DMFC) can be made more compact, lighter, and less costly by changing the material used in its construction. 2. Controlling the fuel diffusion rate through the cell improves the performance of the cell. A passive liquid feed direct methanol fuel cell (DMFC) was fabricated using a given MEA (Membrane Electrode Assembly) and tested for different current collector structures. Mesh current collectors of different mesh densities along with different support structures, were used, and the performance was found to be better. Methanol concentration was also varied. Optimisation of mesh size, support structure, and fuel concentration was achieved. Cost analysis was also performed hereby. From the performance analysis study of DMFC, we can conclude with the following points: Area specific resistance (ASR) of wire mesh current collectors is lower than the ASR of stainless steel current collectors. Also, the power produced by wire mesh current collectors is always more than that produced by stainless steel current collectors. 1. Low or moderate methanol concentrations should be used for better and stable DMFC performance. 2. Wiremesh is a good substitute for stainless steel for current collector plates of passive DMFC because of its lower cost (by about 27 %), flexibility, and light in weight characteristics of wire mesh.Keywords: direct methanol fuel cell, membrane electrode assembly, mesh, mesh size, methanol concentration, support structure
Procedia PDF Downloads 8013466 Cephalometric Changes of Patient with Class II Division 1 [Malocclusion] Post Orthodontic Treatment with Growth Stimulation: A Case Report
Authors: Pricillia Priska Sianita
Abstract:
An aesthetic facial profile is one of the goals in Orthodontics treatment. However, this is not easily achieved, especially in patients with Class II Division 1 malocclusion who have the clinical characteristics of convex profile and significant skeletal discrepancy due to mandibular growth deficiency. Malocclusion with skeletal problems require proper treatment timing for growth stimulation, and it must be done in early age and in need of good cooperation from the patient. If this is not done and the patient has passed the growth period, the ideal treatment is orthognathic surgery which is more complicated and more painful. The growth stimulation of skeletal malocclusion requires a careful cephalometric evaluation ranging from diagnosis to determine the parts that require stimulation to post-treatment evaluation to see the success achieved through changes in the measurement of the skeletal parameters shown in the cephalometric analysis. This case report aims to describe skeletal changes cephalometrically that were achieved through orthodontic treatment in growing period. Material and method: Lateral Cephalograms, pre-treatment, and post-treatment of cases of Class II Division 1 malocclusion is selected from a collection of cephalometric radiographic in a private clinic. The Cephalogram is then traced and measured for the skeletal parameters. The result is noted as skeletal condition data of pre-treatment and post-treatment. Furthermore, superimposition is done to see the changes achieved. The results show that growth stimulation through orthodontic treatment can solve the skeletal problem of Class II Division 1 malocclusion and the skeletal changes that occur can be verified through cephalometric analysis. The skeletal changes have an impact on the improvement of patient's facial profile. To sum up, the treatment timing on a skeletal malocclusion is very important to obtain satisfactory results for the improvement of the aesthetic facial profile, and skeletal changes can be verified through cephalometric evaluation of pre- and post-treatment.Keywords: cephalometric evaluation, class II division 1 malocclusion, growth stimulation, skeletal changes, skeletal problems
Procedia PDF Downloads 24913465 The Comparative Electroencephalogram Study: Children with Autistic Spectrum Disorder and Healthy Children Evaluate Classical Music in Different Ways
Authors: Galina Portnova, Kseniya Gladun
Abstract:
In our EEG experiment participated 27 children with ASD with the average age of 6.13 years and the average score for CARS 32.41 and 25 healthy children (of 6.35 years). Six types of musical stimulation were presented, included Gluck, Javier-Naida, Kenny G, Chopin and other classic musical compositions. Children with autism showed orientation reaction to the music and give behavioral responses to different types of music, some of them might assess stimulation by scales. The participants were instructed to remain calm. Brain electrical activity was recorded using a 19-channel EEG recording device, 'Encephalan' (Russia, Taganrog). EEG epochs lasting 150 s were analyzed using EEGLab plugin for MatLab (Mathwork Inc.). For EEG analysis we used Fast Fourier Transform (FFT), analyzed Peak alpha frequency (PAF), correlation dimension D2 and Stability of rhythms. To express the dynamics of desynchronizing of different rhythms we've calculated the envelope of the EEG signal, using the whole frequency range and a set of small narrowband filters using Hilbert transformation. Our data showed that healthy children showed similar EEG spectral changes during musical stimulation as well as described the feelings induced by musical fragments. The exception was the ‘Chopin. Prelude’ fragment (no.6). This musical fragment induced different subjective feeling, behavioral reactions and EEG spectral changes in children with ASD and healthy children. The correlation dimension D2 was significantly lower in autists compared to healthy children during musical stimulation. Hilbert envelope frequency was reduced in all group of subjects during musical compositions 1,3,5,6 compositions compared to the background. During musical fragments 2 and 4 (terrible) lower Hilbert envelope frequency was observed only in children with ASD and correlated with the severity of the disease. Alfa peak frequency was lower compared to the background during this musical composition in healthy children and conversely higher in children with ASD.Keywords: electroencephalogram (EEG), emotional perception, ASD, musical perception, childhood Autism rating scale (CARS)
Procedia PDF Downloads 28413464 Efficacy and Safety of Electrical Vestibular Stimulation on Adults with Symptoms of Insomnia: A Double-Blind, Randomized, Sham-Controlled Trial
Authors: Teris Cheung, Joyce Yuen Ting Lam, Kwan Hin Fong, Calvin Pak-Wing Cheng, Julie Sittlington, Yu-Tao Xiang, Tim Man Ho Li
Abstract:
Insomnia is one of the most common health problems in the general population. Insomnia can be acute, intermittent, and become chronic, often due to comorbidity with other physical and mental health conditions. Although there are conventional pharmaceutical and psychotherapeutic treatments to treat symptoms of insomnia, however; there is no robust and novel randomized controlled trial (RCT) using transdermal neurostimulation on individuals with insomnia symptoms. This gives us the impetus to execute the first nationwide RCT. Aim: To evaluate the efficacy of Electrical Vestibular Stimulation (VeNS) on individuals with insomnia in Hong Kong. Design: This study was a two-armed, double blinded, randomized, sham-controlled trial. Sampling: 60 community-dwelling adults aged 18 and 60 years with moderate insomnia symptoms or above (Insomnia Severity Index > 14) were recruited. All subjects were computerized randomized into either the active VeNS group or the sham VeNS group on a 1:1 ratio. Intervention: All participants received a home-use VeNS device and used 30-min VeNS sessions during five consecutive days across a 4-week period (total treatment hours: 10). Baseline measurements and post-VeNS evaluation of the psychological outcomes, including 1) insomnia severity, 2) sleep quality, and 3) quality of life were investigated. The short-and long-term sustainability of the VeNS intervention was assessed immediately after poststim and at a 1-month and 3-month follow-up period. Data analysis: A mixed GEE model was used to analyze the repeated measures data. Missing data were managed by multiple imputations. The level of significance was set to p < 0.05. Significance of the study: This is the first trial to examine the efficacy and safety of VeNS among adults with insomnia symptoms in Hong Kong. Findings that emerged were used to determine whether this VeNS device can be considered a self-help technological device to reduce the severity of insomnia in the community setting and to reduce the global disease burden. Clinical Trial Registration: ClinicalTrials.gov, identifier: NCT04452981.Keywords: adults, insomnia, neuromodulation, rct, vestibular stimulation
Procedia PDF Downloads 8213463 Correlations Between Electrical Resistivity and Some Properties of Clayey Soils
Authors: F. A. Hassona, M. M. Abu-Heleika, M. A. Hassan, A. E. Sidhom
Abstract:
Application of electrical measurements to evaluate engineering properties of soils has gained a wide, promising field of research in recent years. So, understanding of the relation between in-situ electrical resistivity of clay soil, and their mechanical and physical properties consider a promising field of research. This would assist in introducing a new technique for the determination of soil properties based on electrical resistivity. In this work soil physical and mechanical properties of clayey soil have been determined by experimental tests and correlated with the in-situ electrical resistivity. The research program was conducted through measuring fifteen vertical electrical sounding stations along with fifteen selected boreholes. These samples were analyzed and subjected to experimental tests such as physical tests namely bulk density, water content, specific gravity, and grain size distribution, and Attereberg limits tests. Mechanical test was also conducted such as direct shear test. The electrical resistivity data were interpreted and correlated with each one of the measured experimental parameters. Based on this study mathematical relations were extracted and discussed. These results exhibit an excellent match with the results reported in the literature. This study demonstrates the utility of the developed methodology for determining the mechanical properties of soils easily and rapidly depending on their electrical resistivity measurements.Keywords: electrical resistivity, clayey soil, physical properties, shear properties
Procedia PDF Downloads 29413462 Asymmetrically Contacted Tellurium Short-Wave Infrared Photodetector with Low Dark Current and High Sensitivity at Room Temperature
Authors: Huang Haoxin
Abstract:
Large dark current at room temperature has long been the major bottleneck that impedes the development of high-performance infrared photodetectors towards miniaturization and integration. Although infrared photodetectors based on layered 2D narrow bandgap semiconductors have shown admirable advantages compared with those based on conventional compounds, which typically suffer from expensive cryogenic operations, it is still urgent to develop a simple but effective strategy to further reduce the dark current. Herein, a tellurium (Te) based infrared photodetector is reported with a specifically designed asymmetric electrical contact area. The deliberately introduced asymmetric electrical contact raises the electric field intensity difference in the Te channel near the drain and the source electrodes, resulting in spontaneous asymmetric carrier diffusion under global infrared light illumination under zero bias. Specifically, the Te-based photodetector presents promising detector performance at room temperature, including a low dark current of≈1 nA, an ultrahigh photocurrent/dark current ratio of 1.57×10⁴, a high specific detectivity (D*) of 3.24×10⁹ Jones, and relatively fast response speed of ≈720 μs at zero bias. The results prove that the simple design of asymmetric electrical contact areas can provide a promising solution to high-performance 2D semiconductor-based infrared photodetectors working at room temperature.Keywords: asymmetrical contact, tellurium, dark current, infrared photodetector, sensitivity
Procedia PDF Downloads 5113461 Efficacy of Transcranial Magnetic Therapy on Balance in Patients with Stroke
Authors: Nawal A. Abu-Shady, Ibrahim M. I. Hamoda, Ahmed R. Z. Baghdadi, Mohammed K. Mohamed
Abstract:
Background: The aim of this work was to investigate the efficacy of Transcranial Magnetic Therapy (TMT) on balance in hemiparetic stroke patients. It was conducted in outpatient clinic and in BIODEX balance system lab in Faculty of Physical Therapy, Cairo University. Subjects and Methods: Thirty hemiparetic stroke patients from both sexes represent the sample of this study. The patients' ages ranged from 45 to 55 years. They were assigned randomly into two equal groups; the study group (GA) and the control group (GB). control group treated by selected therapeutic physical therapy program. GA treated by the same program of treatment as the GB in addition to TMT. The duration of treatment was six weeks, three times weekly.day after day. The different aspects of dynamic balance (overall stability, anteroposterior stability and mediolateral stability indices) were assessed pre and post treatment objectively by Biodex balance system and clinically by Short Form of Berg Balance Scale (SFBBS) in both groups. Results: Comparison of each variable pre and post treatment in each group revealed a significant improvement in all different parameters in both groups ( p < 0.01), however comparison between post results revealed that the GA showed a high significant improvement higher than the GB in all different variables.Keywords: stroke, TMT, SFBBS, biodex balance system
Procedia PDF Downloads 35613460 Suitability Verification of Cellulose Nanowhisker as a Scaffold for Bone Tissue Engineering
Authors: Moon Hee Jung, Dae Seung Kim, Sang-Myung Jung, Gwang Heum Yoon, Hoo Cheol Lee, Hwa Sung Shin
Abstract:
Scaffolds are an important part to support growth and differentiation of osteoblast for regeneration of injured bone in bone tissue engineering. We utilized tunicate cellulose nanowhisker (CNW) as scaffold and developed complex system that can enhance differentiation of osteoblast by applying mechanical stimulation. CNW, a crystal form of cellulose, has high stiffness with a large surface area and is useful as a biomedical material due to its biodegradability and biocompatibility. In this study, CNW was obtained from tunicate extraction and was confirmed for its adhesion, differentiation, growth of osteoblast without cytotoxicity. In addition, osteoblast was successfully differentiated under mechanical stimulation, followed by calcium dependent signaling. In conclusion, we verified suitability of CNW as scaffold and possibility of bone substitutes.Keywords: osteoblast, cellulose nanowhisker, CNW, mechanical stimulation, bone tissue engineering, bone substitute
Procedia PDF Downloads 36613459 Pharmacodynamic Enhancement of Repetitive rTMS Treatment Outcomes for Major Depressive Disorder
Authors: A. Mech
Abstract:
Repetitive transcranial magnetic stimulation has proven to be a valuable treatment option for patients who have failed to respond to multiple courses of antidepressant medication. In fact, the American Psychiatric Association recommends TMS after one failed treatment course of antidepressant medication. Genetic testing has proven valuable for pharmacokinetic variables, which, if understood, could lead to more efficient dosing of psychotropic medications to improve outcomes. Pharmacodynamic testing can identify biomarkers, which, if addressed, can improve patients' outcomes in antidepressant therapy. Monotherapy treatment of major depressive disorder with methylated B vitamin treatment has been shown to be safe and effective in patients with MTHFR polymorphisms without waiting for multiple trials of failed medication treatment for depression. Such treatment has demonstrated remission rates similar to antidepressant clinical trials. Combining pharmacodynamics testing with repetitive TMS treatment with NeuroStar has shown promising potential for enhancing remission rates and durability of treatment. In this study, a retrospective chart review (ongoing) of patients who obtained repetitive TMS treatment enhanced by dietary supplementation guided by Pharmacodynamic testing, displayed a greater remission rate (90%) than patients treated with only NeuroStar TMS (62%).Keywords: improved remission rate, major depressive disorder, pharmacodynamic testing, rTMS outcomes
Procedia PDF Downloads 5613458 Effect of Pioglitazone on Intracellular Na+ Homeostasis in Metabolic Syndrome-Induced Cardiomyopathy in Male Rats
Authors: Ayca Bilginoglu, Belma Turan
Abstract:
Metabolic syndrome, is associated impaired blood glucose level, insulin resistance, dyslipidemia caused by abdominal obesity. Also, it is related with cardiovascular risk accumulation and cardiomyopathy. The hypothesis of this study was to examine the effect of thiazolidinediones such as pioglitazone which is widely used insulin-sensitizing agents that improve glycemic control, on intracellular Na+ homeostasis in metabolic syndrome-induced cardiomyopathy in male rats. Male Wistar-Albino rats were randomly divided into three groups, namely control (Con, n=7), metabolic syndrome (MetS, n=7) and pioglitazone treated metabolic syndrome group (MetS+PGZ, n=7). Metabolic syndrome was induced by providing drinking water that was 32% sucrose, for 18 weeks. All of the animals were exposed to a 12 h light – 12 h dark cycle. Abdominal obesity and glucose intolerance had measured as a marker of metabolic syndrome. Intracellular Na+ ([Na+]i) is an important modulator of excitation–contraction coupling in heart. [Na+]i at rest and [Na+]i during pacing with electrical field stimulation in 0.2 Hz, 0.8 Hz, 2.0 Hz stimulation frequency were recorded in cardiomyocytes. Also, Na+ channel current (INa) density and I-V curve were measured to understand [Na+]i homeostasis. In results, high sucrose intake, as well as the normal daily diet, significantly increased body mass and blood glucose level of the rats in the metabolic syndrome group as compared with the non-treated control group. In MetS+PZG group, the blood glucose level and body inclined to decrease to the Con group. There was a decrease in INa density and there was a shift both activation and inactivation curve of INa. Pioglitazone reversed the shift to the control side. Basal [Na+]i either MetS and Con group were not significantly different, but there was a significantly increase in [Na+]i in stimulated cardiomyocytes in MetS group. Furthermore, pioglitazone had not effect on basal [Na+]i but it reversed the increase in [Na+]i in stimulated cardiomyocytes to the that of Con group. Results of the present study suggest that pioglitazone has a significant effect on the Na+ homeostasis in the metabolic syndrome induced cardiomyopathy in rats. All animal procedures and experiments were approved by the Animal Ethics Committee of Ankara University Faculty of Medicine (2015-2-37).Keywords: insulin resistance, intracellular sodium, metabolic syndrome, sodium current
Procedia PDF Downloads 28513457 Direct CP Violation in Baryonic B-Hadron Decays
Authors: C. Q. Geng, Y. K. Hsiao
Abstract:
We study direct CP-violating asymmetries (CPAs) in the baryonic B decays of B- -> p\bar{p}M and Λb decays of Λb ®pM andΛb -> J/ΨpM with M=π-, K-,ρ-,K*- based on the generalized factorization method in the standard model (SM). In particular, we show that the CPAs in the vector modes of B-®p\bar{p}K* and Λb -> p K*- can be as large as 20%. We also discuss the simplest purely baryonic decays of Λb-> p\bar{p}n, p\bar{p}Λ, Λ\bar{p}Λ, and Λ\bar{Λ}Λ. We point out that some of CPAs are promising to be measured by the current as well as future B facilities.Keywords: CP violation, B decays, baryonic decays, Λb decays
Procedia PDF Downloads 25513456 Evaluation of the Diagnostic Potential of IL-2 after Specific Antigen Stimulation with PE35 (Rv3872) and PPE68 (Rv3873) for the Discrimination of Active and Latent Tuberculosis
Authors: Shima Mahmoudi, Babak Pourakbari, Setareh Mamishi, Mostafa Teymuri, Majid Marjani
Abstract:
Although cytokine analysis has greatly contributed to the understanding of tuberculosis (TB) pathogenesis, data on cytokine profiles that might distinguish progression from latency of TB infection are scarce. Since PE/PPE proteins are known to induce strong humoral and cellular immune responses, the aim of this study was to evaluate the diagnostic potential of interleukin-2 (IL-2) as biomarker after specific antigen stimulation with PE35 and PPE68 for the discrimination of active and latent tuberculosis infection (LTBI). The production of IL-2 was measured in the antigen-stimulated whole-blood supernatants following stimulation with recombinant PE35 and PPE68. All the patients with active TB and LTBI had positive QuantiFERON-TB Gold in Tube test. The level of IL-2 following stimulation with recombinant PE35 and PPE68 were significantly higher in LTBI group than in patients with active TB infection or control group. The discrimination performance (assessed by the area under ROC curve) for IL-2 following stimulation with recombinant PE35 and PPE68 between LTBI and patients with active TB were 0.837 (95%CI: 0.72-0.97) and 0.75 (95%CI: 0.63-0.89), respectively. Applying the 12.4 pg/mL cut-off for IL-2 induced by PE35 in the present study population resulted in sensitivity of 78%, specificity of 78%, PPV of 78% and NPV of 100%. In addition, a sensitivity of 81%, specificity of 70%, PPV of 67% and 87% of NPV was reported based on the 4.4 pg/mL cut-off for IL-2 induced by PPE68. In conclusion, peptides of the antigen PE35 and PPE68, absent from commonly used BCG strains, stimulated strong IL-2- positive T cell responses in patients with LTBI. This study confirms IL-2 induced by PE35 and PPE68 as a sensitive and specific biomarker and highlights IL-2 as new promising adjunct markers for discriminating of LTBI and Active TB infection.Keywords: IL-2, PE35, PPE68, tuberculosis
Procedia PDF Downloads 409