Search results for: direct current control
21042 Solutions for Quality Pre-Control of Crimp Contacts
Authors: C. F. Ocoleanu, G. Cividjian, Gh. Manolea
Abstract:
In this paper, we present two solutions for connections quality pre-control of Crimp Contacts and to identify in the first moments the connections improperly executed, before final assembly of a electrical machines. The first solution supposed experimental determination of specific losses by calculated the initial rate of temperature rise. This can be made drawing the tangent at the origin at heating curve. The method can be used to identify bad connections by passing a current through the winding at ambient temperature and simultaneously record connections temperatures in the first few minutes since the current is setting. The second proposed solution is to apply to each element crimping a thermal indicator one level, and making a test heating with a heating current corresponding to critical temperature indicator.Keywords: temperature, crimp contact, thermal indicator, current distribution, specific losses
Procedia PDF Downloads 42321041 EWMA and MEWMA Control Charts for Monitoring Mean and Variance in Industrial Processes
Authors: L. A. Toro, N. Prieto, J. J. Vargas
Abstract:
There are many control charts for monitoring mean and variance. Among these, the X y R, X y S, S2 Hotteling and Shewhart control charts, for mentioning some, are widely used for monitoring mean a variance in industrial processes. In particular, the Shewhart charts are based on the information about the process contained in the current observation only and ignore any information given by the entire sequence of points. Moreover, that the Shewhart chart is a control chart without memory. Consequently, Shewhart control charts are found to be less sensitive in detecting smaller shifts, particularly smaller than 1.5 times of the standard deviation. These kind of small shifts are important in many industrial applications. In this study and effective alternative to Shewhart control chart was implemented. In case of univariate process an Exponentially Moving Average (EWMA) control chart was developed and Multivariate Exponentially Moving Average (MEWMA) control chart in case of multivariate process. Both of these charts were based on memory and perform better that Shewhart chart while detecting smaller shifts. In these charts, information the past sample is cumulated up the current sample and then the decision about the process control is taken. The mentioned characteristic of EWMA and MEWMA charts, are of the paramount importance when it is necessary to control industrial process, because it is possible to correct or predict problems in the processes before they come to a dangerous limit.Keywords: control charts, multivariate exponentially moving average (MEWMA), exponentially moving average (EWMA), industrial control process
Procedia PDF Downloads 35521040 Development of a Direct Immunoassay for Human Ferritin Using Diffraction-Based Sensing Method
Authors: Joel Ballesteros, Harriet Jane Caleja, Florian Del Mundo, Cherrie Pascual
Abstract:
Diffraction-based sensing was utilized in the quantification of human ferritin in blood serum to provide an alternative to label-based immunoassays currently used in clinical diagnostics and researches. The diffraction intensity was measured by the diffractive optics technology or dotLab™ system. Two methods were evaluated in this study: direct immunoassay and direct sandwich immunoassay. In the direct immunoassay, human ferritin was captured by human ferritin antibodies immobilized on an avidin-coated sensor while the direct sandwich immunoassay had an additional step for the binding of a detector human ferritin antibody on the analyte complex. Both methods were repeatable with coefficient of variation values below 15%. The direct sandwich immunoassay had a linear response from 10 to 500 ng/mL which is wider than the 100-500 ng/mL of the direct immunoassay. The direct sandwich immunoassay also has a higher calibration sensitivity with value 0.002 Diffractive Intensity (ng mL-1)-1) compared to the 0.004 Diffractive Intensity (ng mL-1)-1 of the direct immunoassay. The limit of detection and limit of quantification values of the direct immunoassay were found to be 29 ng/mL and 98 ng/mL, respectively, while the direct sandwich immunoassay has a limit of detection (LOD) of 2.5 ng/mL and a limit of quantification (LOQ) of 8.2 ng/mL. In terms of accuracy, the direct immunoassay had a percent recovery of 88.8-93.0% in PBS while the direct sandwich immunoassay had 94.1 to 97.2%. Based on the results, the direct sandwich immunoassay is a better diffraction-based immunoassay in terms of accuracy, LOD, LOQ, linear range, and sensitivity. The direct sandwich immunoassay was utilized in the determination of human ferritin in blood serum and the results are validated by Chemiluminescent Magnetic Immunoassay (CMIA). The calculated Pearson correlation coefficient was 0.995 and the p-values of the paired-sample t-test were less than 0.5 which show that the results of the direct sandwich immunoassay was comparable to that of CMIA and could be utilized as an alternative analytical method.Keywords: biosensor, diffraction, ferritin, immunoassay
Procedia PDF Downloads 35421039 A Novel Design Methodology for a 1.5 KW DC/DC Converter in EV and Hybrid EV Applications
Authors: Farhan Beg
Abstract:
This paper presents a method for the efficient implementation of a unidirectional or bidirectional DC/DC converter. The DC/DC converter is used essentially for energy exchange between the low voltage service battery and a high voltage battery commonly found in Electric Vehicle applications. In these applications, apart from cost, efficiency of design is an important characteristic. A useful way to reduce the size of electronic equipment in the electric vehicles is proposed in this paper. The technique simplifies the mechanical complexity and maximizes the energy usage using the latest converter control techniques. Moreover a bidirectional battery charger for hybrid electric vehicles is also implemented in this paper. Several simulations on the test system have been carried out in Matlab/Simulink environment. The results exemplify the robustness of the proposed design methodology in case of a 1.5 KW DC-DC converter.Keywords: DC-DC converters, electric vehicles, power electronics, direct current control
Procedia PDF Downloads 72721038 Two-Level Separation of High Air Conditioner Consumers and Demand Response Potential Estimation Based on Set Point Change
Authors: Mehdi Naserian, Mohammad Jooshaki, Mahmud Fotuhi-Firuzabad, Mohammad Hossein Mohammadi Sanjani, Ashknaz Oraee
Abstract:
In recent years, the development of communication infrastructure and smart meters have facilitated the utilization of demand-side resources which can enhance stability and economic efficiency of power systems. Direct load control programs can play an important role in the utilization of demand-side resources in the residential sector. However, investments required for installing control equipment can be a limiting factor in the development of such demand response programs. Thus, selection of consumers with higher potentials is crucial to the success of a direct load control program. Heating, ventilation, and air conditioning (HVAC) systems, which due to the heat capacity of buildings feature relatively high flexibility, make up a major part of household consumption. Considering that the consumption of HVAC systems depends highly on the ambient temperature and bearing in mind the high investments required for control systems enabling direct load control demand response programs, in this paper, a recent solution is presented to uncover consumers with high air conditioner demand among large number of consumers and to measure the demand response potential of such consumers. This can pave the way for estimating the investments needed for the implementation of direct load control programs for residential HVAC systems and for estimating the demand response potentials in a distribution system. In doing so, we first cluster consumers into several groups based on the correlation coefficients between hourly consumption data and hourly temperature data using K-means algorithm. Then, by applying a recent algorithm to the hourly consumption and temperature data, consumers with high air conditioner consumption are identified. Finally, demand response potential of such consumers is estimated based on the equivalent desired temperature setpoint changes.Keywords: communication infrastructure, smart meters, power systems, HVAC system, residential HVAC systems
Procedia PDF Downloads 6921037 An Approach towards Elementary Investigation on HCCI Technology
Authors: Jitendra Sharma
Abstract:
Here a Homogeneous Charge is used as in a spark-ignited engine, but the charge is compressed to auto ignition as in a diesel. The main difference compared with the Spark Ignition (SI) engine is the lack of flame propagation and hence the independence from turbulence. Compared with the diesel engine. HCCI has a homogeneous charge and have no problems associated with soot and Nox but HC and CO were higher than in SI mode. It was not possible to achieve high IMEP (Indicated Mean Effective Pressure) values with HCCI. The Homogeneous charge compression ignition (HCCI) is an attractive technology because of its high efficiency and low emissions. However, HCCI lakes a direct combustion trigger making control of combustion timing challenging, especially during transients. To aid in HCCI engine control we present a simple model of the HCCI combustion process valid over a range of intake pressures, intake temperatures, equivalence ratios and engine speeds. HCCI a new combustion technology that may develop as an alternative to diesel engines with high efficiency and low Knox and particulate matter emissions. The homogenous charge compression ignition (HCCI) is a promising new engine technology that combines elements of the diesel and gasoline engine operating cycles. HCCI as a way to increase the efficiency of the gasoline engine. The attractive properties are increased fuel efficiency due to reduced throttling losses, increased expansion ratio and higher thermodynamic efficiency. With the advantages there are some mechanical limitations to the operation of the HCCI engine. The implementation of homogenous charge compression ignition (HCCI) to gasoline engines is constrained by many factors. The main drawback of HCCI is the absence of direct combustion timing control. Therefore all the right conditions for auto ignition have to be set before combustion starts. This paper describes the past and current research done on HCCI engine. Many research got considerable success in doing detailed modeling of HCCI combustion. This paper aims at studying the fundamentals of HCCI combustion, the strategy to control the limitation of HCCI engine.Keywords: HCCI, diesel engine, combustion, elementary investigation
Procedia PDF Downloads 44421036 Hardware Co-Simulation Based Based Direct Torque Control for Induction Motor Drive
Authors: Hanan Mikhael Dawood, Haider Salim, Jafar Al-Wash
Abstract:
This paper presents Proportional-Integral (PI) controller to improve the system performance which gives better torque and flux response. In addition, it reduces the undesirable torque ripple. The conventional DTC controller approach for induction machines, based on an improved torque and stator flux estimator, is implemented using Xilinx System Generator (XSG) for MATLAB/Simulink environment through Xilinx blocksets. The design was achieved in VHDL which is based on a MATLAB/Simulink simulation model. The hardware in the loop results are obtained considering the implementation of the proposed model on the Xilinx NEXYS2 Spartan 3E1200 FG320 Kit.Keywords: induction motor, Direct Torque Control (DTC), Xilinx FPGA, motor drive
Procedia PDF Downloads 62221035 Acquisition of French (L3) Direct Object by Persian (L1) Speakers of English (L2) as EFL Learners
Authors: Ali Akbar Jabbari
Abstract:
The present study assessed the acquisition of L3 French direct objects by Persian speakers who had already learned English as their L2. The ultimate goal of this paper is to extend the current knowledge about the CLI phenomenon in the realm of third language acquisition by examining the role of Persian and English as background languages and learners’ English level of proficiency in their performance on French direct object. To fulfill this, the assumptions of three L3 hypotheses, namely L1 Transfer, L2 Status Factor, and Cumulative Enhancement Model, were examined. The research sample was comprised of 40 undergraduate students in the fields of English language and literature and translation studies at Birjand University in Iran. According to the English proficiency level of learners revealed by the Quick Oxford English Placement test, the participants were grouped as upper intermediate and lower intermediate. A grammaticality judgment and a translation test were administered to gather the required data on learners' comprehension and production of the desired structure in French. It was demonstrated that the rate of positive transfer from previously learned languages was more potent than the rate of negative transfer. A Comparison of groups' performances revealed a significant difference between upper and lower intermediate groups in positing French direct objects correctly. However, the upper intermediate group did not significantly differ from the lower intermediate group in negative transfer. It can be said that by increasing the L2 proficiency of the learners, they could use their previous linguistic knowledge more efficiently. Although further examinations are needed, the current study contributed to a better characterization of cross-linguistic influence in third language acquisition. The findings help French teachers and learners to positively exploit the prior knowledge of Persian and English and apply it in in the multilingual context of French direct object's teaching and learning process.Keywords: Cross-Linguistic Influence, Persian, French & English Direct Object, Third Language Acquisition, Language Transfer
Procedia PDF Downloads 6921034 Neural Nets Based Approach for 2-Cells Power Converter Control
Authors: Kamel Laidi, Khelifa Benmansour, Ouahid Bouchhida
Abstract:
Neural networks-based approach for 2-cells serial converter has been developed and implemented. The approach is based on a behavioural description of the different operating modes of the converter. Each operating mode represents a well-defined configuration, and for which is matched an operating zone satisfying given invariance conditions, depending on the capacitors' voltages and the load current of the converter. For each mode, a control vector whose components are the control signals to be applied to the converter switches has been associated. Therefore, the problem is reduced to a classification task of the different operating modes of the converter. The artificial neural nets-based approach, which constitutes a powerful tool for this kind of task, has been adopted and implemented. The application to a 2-cells chopper has allowed ensuring efficient and robust control of the load current and a high capacitors voltages balancing.Keywords: neural nets, control, multicellular converters, 2-cells chopper
Procedia PDF Downloads 83621033 Bayesian Borrowing Methods for Count Data: Analysis of Incontinence Episodes in Patients with Overactive Bladder
Authors: Akalu Banbeta, Emmanuel Lesaffre, Reynaldo Martina, Joost Van Rosmalen
Abstract:
Including data from previous studies (historical data) in the analysis of the current study may reduce the sample size requirement and/or increase the power of analysis. The most common example is incorporating historical control data in the analysis of a current clinical trial. However, this only applies when the historical control dataare similar enough to the current control data. Recently, several Bayesian approaches for incorporating historical data have been proposed, such as the meta-analytic-predictive (MAP) prior and the modified power prior (MPP) both for single control as well as for multiple historical control arms. Here, we examine the performance of the MAP and the MPP approaches for the analysis of (over-dispersed) count data. To this end, we propose a computational method for the MPP approach for the Poisson and the negative binomial models. We conducted an extensive simulation study to assess the performance of Bayesian approaches. Additionally, we illustrate our approaches on an overactive bladder data set. For similar data across the control arms, the MPP approach outperformed the MAP approach with respect to thestatistical power. When the means across the control arms are different, the MPP yielded a slightly inflated type I error (TIE) rate, whereas the MAP did not. In contrast, when the dispersion parameters are different, the MAP gave an inflated TIE rate, whereas the MPP did not.We conclude that the MPP approach is more promising than the MAP approach for incorporating historical count data.Keywords: count data, meta-analytic prior, negative binomial, poisson
Procedia PDF Downloads 11921032 Effects of Mental Skill Training Programme on Direct Free Kick of Grassroot Footballers in Lagos, Nigeria
Authors: Mayowa Adeyeye, Kehinde Adeyemo
Abstract:
The direct free kick is considered a great opportunity to score a goal but this is not always the case amidst Nigerian and other elite footballers. This study, therefore, examined the extent to which an 8 weeks mental skill training programme is effective for improving accuracy in direct free kick in football. Sixty (n-60) students of Pepsi Football Academy participated in the study. They were randomly distributed into two groups of positive self-talk group (intervention n-30) and control group (n-30). The instrument used in the collection of data include a standard football goal post while the research materials include a dummy soccer wall, a cord, an improvised vanishing spray, a clipboard, writing materials, a recording sheet, a self-talk log book, six standard 5 football, cones, an audiotape and a compact disc. The Weinberge and Gould (2011) mental skills training manual was used. The reliability coefficient of the apparatus following a pilot study stood at 0.72. Before the commencement of the mental skills training programme, the participants were asked to take six simulated direct free kick. At the end of each physical skills training session after the pre-test, the researcher spent at least 15 minutes with the groups exposing them to the intervention. The mental skills training programme alongside physical skills training took place in two different locations for the different groups under study, these included Agege Stadium Main bowl Football Pitch (Imagery Group), and Ogba Ijaye (Control Group). The mental skills training programme lasted for eight weeks. After the completion of the mental skills training programme, all the participants were asked to take another six simulated direct free kick attempts using the same field used for the pre-test to determine the efficacy of the treatments. The pre-test and post-test data were analysed using inferential statistics of t-test, while the alpha level was set at 0.05. The result revealed significant differences in t-test for positive self-talk and control group. Based on the findings, it is recommended that athletes should be exposed to positive self-talk alongside their normal physical skills training for quality delivery of accurate direct free kick during training and competition.Keywords: accuracy, direct free kick, pepsi football academy, positive self-talk
Procedia PDF Downloads 35021031 Investigating the Effect of Executive Functions on Young Children’s Drawing of Familiar and Unfamiliar
Authors: Reshaa Alruwaili
Abstract:
This study was inspired by previous studies with young children that found (a) that they need both inhibitory control and working memory when drawing an unfamiliar subject (e.g., animals) by adapting their schema of the human figure and (b) that when drawing something familiar (e.g., a person) they use inhibitory control mediated through fine motor control to execute their drawing. This study, therefore, systematically investigated whether direct effects for both working memory and inhibitory control and/or effects mediated through fine motor control existed when drawing both familiar and unfamiliar subjects. Participants were 95 children (41-66 months old) required to draw both a man and a dog, scored respectively for how representational they were and for differences from a human figure. Regression and mediation analyses showed that inhibitory control alone predicted drawing a recognizable man while working memory alone predicted drawing a dog that was not human-like when fine motor control, age, and gender were controlled. Contrasting with some previous studies, these results suggest that the roles of working memory and inhibitory control are sensitive to the familiarity of the drawing task and are not necessarily mediated through fine motor control. Implications for research on drawing development are discussed.Keywords: child drawing, inhibitory control, working memory, fine motor control, mediation, familiar and unfamiliar subjects
Procedia PDF Downloads 7821030 Assessment of Aminopolyether on 18F-FDG Samples
Authors: Renata L. C. Leão, João E. Nascimento, Natalia C. E. S. Nascimento, Elaine S. Vasconcelos, Mércia L. Oliveira
Abstract:
The quality control procedures of a radiopharmaceutical include the assessment of its chemical purity. The method suggested by international pharmacopeias consists of a thin layer chromatographic run. In this paper, the method proposed by the United States Pharmacopeia (USP) is compared to a direct method to determine the final concentration of aminopolyether in Fludeoxyglucose (18F-FDG) preparations. The approach (no chromatographic run) was achieved by placing the thin-layer chromatography (TLC) plate directly on an iodine vapor chamber. Both methods were validated and they showed adequate results to determine the concentration of aminopolyether in 18F-FDG preparations. However, the direct method is more sensitive, faster and simpler when compared to the reference method (with chromatographic run), and it may be chosen for use in routine quality control of 18F-FDG.Keywords: chemical purity, Kryptofix 222, thin layer chromatography, validation
Procedia PDF Downloads 20221029 Energy Management Method in DC Microgrid Based on the Equivalent Hydrogen Consumption Minimum Strategy
Authors: Ying Han, Weirong Chen, Qi Li
Abstract:
An energy management method based on equivalent hydrogen consumption minimum strategy is proposed in this paper aiming at the direct-current (DC) microgrid consisting of photovoltaic cells, fuel cells, energy storage devices, converters and DC loads. The rational allocation of fuel cells and battery devices is achieved by adopting equivalent minimum hydrogen consumption strategy with the full use of power generated by photovoltaic cells. Considering the balance of the battery’s state of charge (SOC), the optimal power of the battery under different SOC conditions is obtained and the reference output power of the fuel cell is calculated. And then a droop control method based on time-varying droop coefficient is proposed to realize the automatic charge and discharge control of the battery, balance the system power and maintain the bus voltage. The proposed control strategy is verified by RT-LAB hardware-in-the-loop simulation platform. The simulation results show that the designed control algorithm can realize the rational allocation of DC micro-grid energy and improve the stability of system.Keywords: DC microgrid, equivalent minimum hydrogen consumption strategy, energy management, time-varying droop coefficient, droop control
Procedia PDF Downloads 30321028 Finite Element Assessment on Bond Behaviour of FRP-to-Concrete Joints under Cyclic Loading
Authors: F. Atheer, Al-Saoudi, Robin Kalfat, Riadh Al-Mahaidi
Abstract:
Over the last two decades, externally bonded fiber reinforced polymer (FRP) composites bonded to concrete substrates has become a popular method for strengthening reinforced concrete (RC) highway and railway bridges. Such structures are exposed to severe cyclic loading throughout their lifetime often resulting in fatigue damage to structural components and a reduction in the service life of the structure. Since experimental and numerical results on the fatigue performance of FRP-to-concrete joints are still limited, the current research focuses on assessing the fatigue performance of externally bonded FRP-to-concrete joints using a direct shear test. Some early results indicate that the stress ratio and the applied cyclic stress level have a direct influence on the fatigue life of the externally bonded FRP. In addition, a calibrated finite element model is developed to provide further insight into the influence of certain parameters such as: concrete strength, FRP thickness, number of cycles, frequency and stiffness on the fatigue life of the FRP-to-concrete joints.Keywords: FRP, concrete bond, control, fatigue, finite element model
Procedia PDF Downloads 45121027 Control Algorithm Design of Single-Phase Inverter For ZnO Breakdown Characteristics Tests
Authors: Kashif Habib, Zeeshan Ayyub
Abstract:
ZnO voltage dependent resistor was widely used as components of the electrical system for over-voltage protection. It has a wide application prospect in superconducting energy-removal, generator de-excitation, overvoltage protection of electrical & electronics equipment. At present, the research for the application of ZnO voltage dependent resistor stop, it uses just in the field of its nonlinear voltage current characteristic and overvoltage protection areas. There is no further study over the over-voltage breakdown characteristics, such as the combustion phenomena and the measure of the voltage/current when it breakdown, and the affect to its surrounding equipment. It is also a blind spot in its application. So, when we do the feature test of ZnO voltage dependent resistor, we need to design a reasonable test power supply, making the terminal voltage keep for sine wave, simulating the real use of PF voltage in power supply conditions. We put forward the solutions of using inverter to generate a controllable power. The paper mainly focuses on the breakdown characteristic test power supply of nonlinear ZnO voltage dependent resistor. According to the current mature switching power supply technology, we proposed power control system using the inverter as the core. The power mainly realize the sin-voltage output on the condition of three-phase PF-AC input, and 3 control modes (RMS, Peak, Average) of the current output. We choose TMS320F2812M as the control part of the hardware platform. It is used to convert the power from three-phase to a controlled single-phase sin-voltage through a rectifier, filter, and inverter. Design controller produce SPWM, to get the controlled voltage source via appropriate multi-loop control strategy, while execute data acquisition and display, system protection, start logic control, etc. The TMS320F2812M is able to complete the multi-loop control quickly and can be a good completion of the inverter output control.Keywords: ZnO, multi-loop control, SPWM, non-linear load
Procedia PDF Downloads 32521026 The Inhibitory Effect of Trichoderma sp. on Mycelial Growth of Fusarium oxysporum f. sp. radicis-lycopersici and Alternaria solani
Authors: A. Y. Benabdellah, W. Lakhdari, A. Dahliz, Y. Bouchikh, A. Soud, R. M'lik, H. Hammi
Abstract:
The direct comparison tests on the culture medium, between Trichoderma sp. and Fusarium oxysporum f. sp. radicis-lycopersici revealed that the latest one could inhibit the growth of F. oxysporum mycelial over than 40% compared to the control and that after four days of incubation at 26° C. Moreover, beyond this period and at the end of six days, Trichoderma sp. invading the colonies of F. oxysporum on what it sporule, thus revealing its power is highly myco-parasitic. Almost similar results were obtained against Alternaria solani is also a pathogen which is not causing a lot of damage, but we found it more sensitive to Trichoderma sp. with a percentage of inhibition more than 50%. So due to the in vitro test of Trichoderma sp. against these aggressive pathogens by direct contact has been found that can inhibit their mycelial growth with high speed and a high inhibition rate.Keywords: Trichoderma sp., Fusarium oxysporum f. sp. radicis-lycopersici, Alternaria solani, biological control, antagonist
Procedia PDF Downloads 38021025 Non-Linear Control in Positioning of PMLSM by Estimates of the Load Force by MRAS Method
Authors: Maamar Yahiaoui, Abdelrrahmene Kechich, Ismail Elkhallile Bousserhene
Abstract:
This article presents a study in simulation by means of MATLAB/Simulink software of the nonlinear control in positioning of a linear synchronous machine with the esteemed force of load, to have effective control in the estimator in all tests the wished trajectory follows and the disturbance of load start. The results of simulation prove clearly that the control proposed can detect the reference of positioning the value estimates of load force equal to the actual value.Keywords: mathematical model, Matlab, PMLSM, control, linearization, estimator, force, load, current
Procedia PDF Downloads 61021024 Design and Simulation of Unified Power Quality Conditioner based on Adaptive Fuzzy PI Controller
Authors: Brahim Ferdi, Samira Dib
Abstract:
The unified power quality conditioner (UPQC), a combination of shunt and series active power filter, is one of the best solutions towards the mitigation of voltage and current harmonics problems in distribution power system. PI controller is very common in the control of UPQC. However, one disadvantage of this conventional controller is the difficulty in tuning its gains (Kp and Ki). To overcome this problem, an adaptive fuzzy logic PI controller is proposed. The controller is composed of fuzzy controller and PI controller. According to the error and error rate of the control system and fuzzy control rules, the fuzzy controller can online adjust the two gains of the PI controller to get better performance of UPQC. Simulations using MATLAB/SIMULINK are carried out to verify the performance of the proposed controller. The results show that the proposed controller has fast dynamic response and high accuracy of tracking the current and voltage references.Keywords: adaptive fuzzy PI controller, current harmonics, PI controller, voltage harmonics, UPQC
Procedia PDF Downloads 55721023 H-Infinity Controller Design for the Switched Reluctance Machine
Authors: Siwar Fadhel, Imen Bahri, Man Zhang
Abstract:
The switched reluctance machine (SRM) has undeniable qualities in terms of low cost and mechanical robustness. However, its highly nonlinear character and its uncertain parameters justify the development of complicated controls. In this paper, authors present the design of a robust H-infinity current controller for an 8/6 SRM with taking into account the nonlinearity of the SRM and with rejection of disturbances. The electromagnetic torque is indirectly regulated through the current controller. To show the performances of this control, a robustness analysis is performed by comparing the H-infinity and PI controller simulation results. This comparison demonstrates better performances for the presented controller. The effectiveness and robustness of the presented controller are also demonstrated by experimental tests.Keywords: current regulation, experimentation, robust H-infinity control, switched reluctance machine
Procedia PDF Downloads 31121022 Direct and Indirect Effects of Childhood Traumas, Emotion Regulation Difficulties and Age on Tendency to Violence
Authors: Selin Kara-Bahçekapılı, Bengisu Nehir Aydın
Abstract:
Objective: In this study, it is aimed to examine the relationship between childhood traumas (overprotection-control, emotional/physical/sexual abuse, emotional/physical neglect), age, emotional regulation difficulties, and the tendency of violence in adults. In the study, the direct and indirect effects of 6 sub-factors of childhood traumas, emotion regulation difficulties, and age on tendency to violence are evaluated on a model that theoretically reveals. Method: The population of this cross-sectional study consists of individuals between the ages of 18-65 living in Turkey. The data from 527 participants were obtained by online surveys and convenience sampling method within the scope of the study. As a result of exclusion criteria and then outlier data analysis, the data of 443 participants were included in the analysis. Data were collected by demographic information form, childhood trauma scale, emotion regulation difficulty scale, and violence tendency scale. Research data were analyzed by SPSS and AMOS using correlation, path analysis, direct and indirect effects. Results: According to the research findings, the variables in the model explained 28.2% of the variance of the mean scores of the individuals' tendency to violence. Emotion regulation difficulties have the most direct effect on the tendency to violence (d=.387; p<.01). The effects of excessive protection and control, emotional neglect, and physical neglect variables on the tendency to violence are not significant. When the significant and indirect effects of the variables on tendency to violence over emotion regulation difficulties are examined, age has a negative effect, emotional neglect has a positive effect, emotional abuse has a positive effect, and overprotection-control has a positive effect. The indirect effects of sexual abuse, physical neglect, and physical abuse on tendency to violence are not significant. Childhood traumas and age variables in the model explained 24.1% of the variance of the mean scores of the individuals’ emotion regulation difficulties. The variable that most affects emotion regulation difficulties is age (d=-.268; p<.001). The direct effects of sexual abuse, physical neglect, and physical abuse on emotion regulation difficulties are not significant. Conclusion: The results of the research emphasize the critical role of difficulty in emotion regulation on the tendency to violence. Difficulty in emotion regulation affects the tendency to violence both directly and by mediating different variables. In addition, it is seen that some sub-factors of childhood traumas have direct and/or indirect effects on the tendency to violence. Emotional abuse and age have both direct and indirect effects on the tendency to violence over emotion regulation difficulties.Keywords: childhood trauma, emotion regulation difficulties, tendency to violence, path analysis
Procedia PDF Downloads 9721021 Simulation Based Performance Comparison of Different Control Methods of ZSI Feeding Industrial Drives
Authors: Parag Nihawan, Ravinder Singh Bhatia, Dinesh Kumar Jain
Abstract:
Industrial drives are source of serious power quality problems. In this, two typical industrial drives have been dealt with, namely, FOC induction motor drives and DTC induction motor drive. The Z-source inverter is an emerging topology of power electronic converters which is capable of buck boost characteristics. The performances of different control methods based Z-source inverters feeding these industrial drives have been investigated, in this work. The test systems have been modeled and simulated in MATLAB/SIMULINK. The results obtained after carrying out these simulations have been used to draw the conclusions.Keywords: Z-source inverter, total harmonic distortion, direct torque control, field orientation control
Procedia PDF Downloads 58221020 Temperature Control Improvement of Membrane Reactor
Authors: Pornsiri Kaewpradit, Chalisa Pourneaw
Abstract:
Temperature control improvement of a membrane reactor with exothermic and reversible esterification reaction is studied in this work. It is well known that a batch membrane reactor requires different control strategies from a continuous one due to the fact that it is operated dynamically. Due to the effect of the operating temperature, the suitable control scheme has to be designed based reliable predictive model to achieve a desired objective. In the study, the optimization framework has been preliminary formulated in order to determine an optimal temperature trajectory for maximizing a desired product. In model predictive control scheme, a set of predictive models have been initially developed corresponding to the possible operating points of the system. The multiple predictive control moves have been further calculated on-line using the developed models corresponding to current operating point. It is obviously seen in the simulation results that the temperature control has been improved compared to the performance obtained by the conventional predictive controller. Further robustness tests have also been investigated in this study.Keywords: model predictive control, batch reactor, temperature control, membrane reactor
Procedia PDF Downloads 46921019 A Low-Power, Low-Noise and High-Gain 58~66 GHz CMOS Receiver Front-End for Short-Range High-Speed Wireless Communications
Authors: Yo-Sheng Lin, Jen-How Lee, Chien-Chin Wang
Abstract:
A 60-GHz receiver front-end using standard 90-nm CMOS technology is reported. The receiver front-end comprises a wideband low-noise amplifier (LNA), and a double-balanced Gilbert cell mixer with a current-reused RF single-to-differential (STD) converter, an LO Marchand balun and a baseband amplifier. The receiver front-end consumes 34.4 mW and achieves LO-RF isolation of 60.7 dB, LO-IF isolation of 45.3 dB and RF-IF isolation of 41.9 dB at RF of 60 GHz and LO of 59.9 GHz. At IF of 0.1 GHz, the receiver front-end achieves maximum conversion gain (CG) of 26.1 dB at RF of 64 GHz and CG of 25.2 dB at RF of 60 GHz. The corresponding 3-dB bandwidth of RF is 7.3 GHz (58.4 GHz to 65.7 GHz). The measured minimum noise figure was 5.6 dB at 64 GHz, one of the best results ever reported for a 60 GHz CMOS receiver front-end. In addition, the measured input 1-dB compression point and input third-order inter-modulation point are -33.1 dBm and -23.3 dBm, respectively, at 60 GHz. These results demonstrate the proposed receiver front-end architecture is very promising for 60 GHz direct-conversion transceiver applications.Keywords: CMOS, 60 GHz, direct-conversion transceiver, LNA, down-conversion mixer, marchand balun, current-reused
Procedia PDF Downloads 45221018 Negative Sequence-Based Protection Techniques for Microgrid Connected Power Systems
Authors: Isabelle Snyder, Travis Smith
Abstract:
Microgrid protection presents challenges to conventional protection techniques due to the low-induced fault current. Protection relays present in microgrid applications require a combination of settings groups to adjust based on the architecture of the microgrid in islanded and grid-connected modes. In a radial system where the microgrid is at the other end of the feeder, directional elements can be used to identify the direction of the fault current and switch settings groups accordingly (grid-connected or microgrid-connected). However, with multiple microgrid connections, this concept becomes more challenging, and the direction of the current alone is not sufficient to identify the source of the fault current contribution. ORNL has previously developed adaptive relaying schemes through other DOE-funded research projects that will be evaluated and used as a baseline for this research. The four protection techniques in this study are labeled as follows: (1) Adaptive Current only Protection System (ACPS), Intentional (2) Unbalanced Control for Protection Control (IUCPC), (3) Adaptive Protection System with Communication Controller (APSCC) (4) Adaptive Model-Driven Protective Relay (AMDPR).Keywords: adaptive relaying, microgrid protection, sequence components, islanding detection
Procedia PDF Downloads 10021017 Can Illusions of Control Make Us Happy?
Authors: Martina Kaufmann, Thomas Goetz, Anastasiya A. Lipnevich, Reinhard Pekrun
Abstract:
Positive emotions have been shown to benefit from optimistic perceptions, even if these perceptions are illusory. The current research investigated the impact of illusions of control on positive emotions. There is empirical evidence showing that people are more emotionally attentive to losses than to gains. Hence, we expected that, compared to gains, losses in illusory control would have a stronger impact on positive emotions. The results of two experimental studies support this assumption: Participants who experienced gains in illusory control showed no substantial change in positive emotions. However, positive emotions decreased when they perceived a loss in illusory control. These results suggest that a loss of illusory control (but not a gain thereof) mediates the impact of the situation on individuals’ positive emotions. Implications for emotion theory and practice are discussed.Keywords: cognitive appraisal, control, illusions, optimism, positive emotions
Procedia PDF Downloads 64121016 Interpolation Issue in PVNPG-14M Application for Technical Control of Artillery Fire
Authors: Martin Blaha, Ladislav Potužák, Daniel Holesz
Abstract:
This paper focused on application support for technical control of artillery units – PVNPG-14M, especially on interpolation issue. Artillery units of the Army of the Czech Republic, reflecting the current global security neighborhood, can be used outside the Czech Republic. The paper presents principles, evolution and calculation in the process of complete preparation. The paper presents expertise using of application of current artillery communication and information system and suggests the perspective future system. The paper also presents problems in process of complete preparing of fire especially problems in permanently information (firing table) and calculated values. The paper presents problems of current artillery communication and information system and suggests requirements of the future system.Keywords: Fire for Effect, Application, Fire Control, Interpolation method, Software development.
Procedia PDF Downloads 32321015 The Design of PFM Mode DC-DC Converter with DT-CMOS Switch
Authors: Jae-Chang Kwak, Yong-Seo Koo
Abstract:
The high efficiency power management IC (PMIC) with switching device is presented in this paper. PMIC is controlled with PFM control method in order to have high power efficiency at high current level. Dynamic Threshold voltage CMOS (DT-CMOS) with low on-resistance is designed to decrease conduction loss. The threshold voltage of DT-CMOS drops as the gate voltage increase, resulting in a much higher current handling capability than standard MOSFET. PFM control circuits consist of a generator, AND gate and comparator. The generator is made to have 1.2MHz oscillation voltage. The DC-DC converter based on PFM control circuit and low on-resistance switching device is presented in this paper.Keywords: DT-CMOS, PMIC, PFM, DC-DC converter
Procedia PDF Downloads 45121014 Application of Matrix Converter for the Power Control of a DFIG-Based Wind Turbine
Authors: E. Bounadja, M. O. Mahmoudi, A. Djahbar, Z. Boudjema
Abstract:
This paper presents a control approach of the doubly fed induction generator (DFIG) in conjunction with a direct AC-AC matrix converter used in generating mode. This device is intended to be implemented in a variable speed wind energy conversion system connected to the grid. Firstly, we developed a model of matrix converter, controlled by the Venturini modulation technique. In order to control the power exchanged between the stator of the DFIG and the grid, a control law is synthesized using a high order sliding mode controller. The use of this method provides very satisfactory performance for the DFIG control. The overall strategy has been validated on a 2-MW wind turbine driven a DFIG using the Matlab/Simulink.Keywords: doubly fed induction generator (DFIG), matrix converter, high-order sliding mode controller, wind energy
Procedia PDF Downloads 52321013 Optimal Injected Current Control for Shunt Active Power Filter Using Artificial Intelligence
Authors: Brahim Berbaoui
Abstract:
In this paper, a new particle swarm optimization (PSO) based method is proposed for the implantation of optimal harmonic power flow in power systems. In this algorithm approach, proportional integral controller for reference compensating currents of active power filter is performed in order to minimize the total harmonic distortion (THD). The simulation results show that the new control method using PSO approach is not only easy to be implanted, but also very effective in reducing the unwanted harmonics and compensating reactive power. The studies carried out have been accomplished using the MATLAB Simulink Power System Toolbox.Keywords: shunt active power filter, power quality, current control, proportional integral controller, particle swarm optimization
Procedia PDF Downloads 616