Search results for: motion errors
1523 3D Biomechanical Analysis in Shot Put Techniques of International Throwers
Authors: Satpal Yadav, Ashish Phulkar, Krishna K. Sahu
Abstract:
Aim: The research aims at doing a 3 Dimension biomechanical analysis in the shot put techniques of International throwers to evaluate the performance. Research Method: The researcher adopted the descriptive method and the data was subjected to calculate by using Pearson’s product moment correlation for the correlation of the biomechanical parameters with the performance of shot put throw. In all the analyses, the 5% critical level (p ≤ 0.05) was considered to indicate statistical significance. Research Sample: Eight (N=08) international shot putters using rotational/glide technique in male category was selected as subjects for the study. The researcher used the following methods and tools to obtain reliable measurements the instrument which was used for the purpose of present study namely the tesscorn slow-motion camera, specialized motion analyzer software, 7.260 kg Shot Put (for a male shot-putter) and steel tape. All measurement pertaining to the biomechanical variables was taken by the principal investigator so that data collected for the present study was considered reliable. Results: The finding of the study showed that negative significant relationship between the angular velocity right shoulder, acceleration distance at pre flight (-0.70), (-0.72) respectively were obtained, the angular displacement of knee, angular velocity right shoulder and acceleration distance at flight (0.81), (0.75) and (0.71) respectively were obtained, the angular velocity right shoulder and acceleration distance at transition phase (0.77), (0.79) respectively were obtained and angular displacement of knee, angular velocity right shoulder, release velocity shot, angle of release, height of release, projected distance and measured distance as the values (0.76), (0.77), (-0.83), (-0.79), (-0.77), (0.99) and (1.00) were found higher than the tabulated value at 0.05 level of significance. On the other hand, there exists an insignificant relationship between the performance of shot put and acceleration distance [m], angular displacement shot, C.G at release and horizontal release distance on the technique of shot put.Keywords: biomechanics, analysis, shot put, international throwers
Procedia PDF Downloads 1871522 Uncertainty Quantification of Corrosion Anomaly Length of Oil and Gas Steel Pipelines Based on Inline Inspection and Field Data
Authors: Tammeen Siraj, Wenxing Zhou, Terry Huang, Mohammad Al-Amin
Abstract:
The high resolution inline inspection (ILI) tool is used extensively in the pipeline industry to identify, locate, and measure metal-loss corrosion anomalies on buried oil and gas steel pipelines. Corrosion anomalies may occur singly (i.e. individual anomalies) or as clusters (i.e. a colony of corrosion anomalies). Although the ILI technology has advanced immensely, there are measurement errors associated with the sizes of corrosion anomalies reported by ILI tools due limitations of the tools and associated sizing algorithms, and detection threshold of the tools (i.e. the minimum detectable feature dimension). Quantifying the measurement error in the ILI data is crucial for corrosion management and developing maintenance strategies that satisfy the safety and economic constraints. Studies on the measurement error associated with the length of the corrosion anomalies (in the longitudinal direction of the pipeline) has been scarcely reported in the literature and will be investigated in the present study. Limitations in the ILI tool and clustering process can sometimes cause clustering error, which is defined as the error introduced during the clustering process by including or excluding a single or group of anomalies in or from a cluster. Clustering error has been found to be one of the biggest contributory factors for relatively high uncertainties associated with ILI reported anomaly length. As such, this study focuses on developing a consistent and comprehensive framework to quantify the measurement errors in the ILI-reported anomaly length by comparing the ILI data and corresponding field measurements for individual and clustered corrosion anomalies. The analysis carried out in this study is based on the ILI and field measurement data for a set of anomalies collected from two segments of a buried natural gas pipeline currently in service in Alberta, Canada. Data analyses showed that the measurement error associated with the ILI-reported length of the anomalies without clustering error, denoted as Type I anomalies is markedly less than that for anomalies with clustering error, denoted as Type II anomalies. A methodology employing data mining techniques is further proposed to classify the Type I and Type II anomalies based on the ILI-reported corrosion anomaly information.Keywords: clustered corrosion anomaly, corrosion anomaly assessment, corrosion anomaly length, individual corrosion anomaly, metal-loss corrosion, oil and gas steel pipeline
Procedia PDF Downloads 3101521 Assessment of Kinetic Trajectory of the Median Nerve from Wrist Ultrasound Images Using Two Dimensional Baysian Speckle Tracking Technique
Authors: Li-Kai Kuo, Shyh-Hau Wang
Abstract:
The kinetic trajectory of the median nerve (MN) in the wrist has shown to be capable of being applied to assess the carpal tunnel syndrome (CTS), and was found able to be detected by high-frequency ultrasound image via motion tracking technique. Yet, previous study may not quickly perform the measurement due to the use of a single element transducer for ultrasound image scanning. Therefore, previous system is not appropriate for being applied to clinical application. In the present study, B-mode ultrasound images of the wrist corresponding to movements of fingers from flexion to extension were acquired by clinical applicable real-time scanner. The kinetic trajectories of MN were off-line estimated utilizing two dimensional Baysian speckle tracking (TDBST) technique. The experiments were carried out from ten volunteers by ultrasound scanner at 12 MHz frequency. Results verified from phantom experiments have demonstrated that TDBST technique is able to detect the movement of MN based on signals of the past and present information and then to reduce the computational complications associated with the effect of such image quality as the resolution and contrast variations. Moreover, TDBST technique tended to be more accurate than that of the normalized cross correlation tracking (NCCT) technique used in previous study to detect movements of the MN in the wrist. In response to fingers’ flexion movement, the kinetic trajectory of the MN moved toward the ulnar-palmar direction, and then toward the radial-dorsal direction corresponding to the extensional movement. TDBST technique and the employed ultrasound image scanner have verified to be feasible to sensitively detect the kinetic trajectory and displacement of the MN. It thus could be further applied to diagnose CTS clinically and to improve the measurements to assess 3D trajectory of the MN.Keywords: baysian speckle tracking, carpal tunnel syndrome, median nerve, motion tracking
Procedia PDF Downloads 4951520 On a Negative Relation between Bacterial Taxis and Turing Pattern Formation
Authors: A. Elragig, S. Townley, H. Dreiwi
Abstract:
In this paper we introduce a bacteria-leukocyte model with bacteria chemotaxsis. We assume that bacteria develop a tactic defense mechanism as a response to Leukocyte phagocytosis. We explore the effect of this tactic motion on Turing space in two parameter spaces. A fine tuning of bacterial chemotaxis shows a significant effect on developing a non-uniform steady state.Keywords: chemotaxis-diffusion driven instability, bacterial chemotaxis, mathematical biology, ecology
Procedia PDF Downloads 3681519 Flow Visualization and Mixing Enhancement in Y-Junction Microchannel with 3D Acoustic Streaming Flow Patterns Induced by Trapezoidal Triangular Structure using High-Viscous Liquids
Authors: Ayalew Yimam Ali
Abstract:
The Y-shaped microchannel is used to mix both miscible or immiscible fluids with different viscosities. However, mixing at the entrance of the Y-junction microchannel can be a difficult mixing phenomena due to micro-scale laminar flow aspects with the two miscible high-viscosity water-glycerol fluids. One of the most promising methods to improve mixing performance and diffusion mass transfer in laminar flow phenomena is acoustic streaming (AS), which is a time-averaged, second-order steady streaming that can produce rolling motion in the microchannel by oscillating a low-frequency range acoustic transducer and inducing an acoustic wave in the flow field. The developed 3D trapezoidal, triangular structure spine used in this study was created using sophisticated CNC machine cutting tools used to create microchannel mold with a 3D trapezoidal triangular structure spine alone the Y-junction longitudinal mixing region. In order to create the molds for the 3D trapezoidal structure with the 3D sharp edge tip angles of 30° and 0.3mm trapezoidal triangular sharp edge tip depth from PMMA glass (Polymethylmethacrylate) with advanced CNC machine and the channel manufactured using PDMS (Polydimethylsiloxane) which is grown up longitudinally on top surface of the Y-junction microchannel using soft lithography nanofabrication strategies. Flow visualization of 3D rolling steady acoustic streaming and mixing enhancement with high-viscosity miscible fluids with different trapezoidal, triangular structure longitudinal length, channel width, high volume flow rate, oscillation frequency, and amplitude using micro-particle image velocimetry (μPIV) techniques were used to study the 3D acoustic streaming flow patterns and mixing enhancement. The streaming velocity fields and vorticity flow fields show 16 times more high vorticity maps than in the absence of acoustic streaming, and mixing performance has been evaluated at various amplitudes, flow rates, and frequencies using the grayscale value of pixel intensity with MATLAB software. Mixing experiments were performed using fluorescent green dye solution with de-ionized water in one inlet side of the channel, and the de-ionized water-glycerol mixture on the other inlet side of the Y-channel and degree of mixing was found to have greatly improved from 67.42% without acoustic streaming to 0.96.83% with acoustic streaming. The results show that the creation of a new 3D steady streaming rolling motion with a high volume flowrate around the entrance was enhanced by the formation of a new, three-dimensional, intense streaming rolling motion with a high-volume flowrate around the entrance junction mixing zone with the two miscible high-viscous fluids which are influenced by laminar flow fluid transport phenomena.Keywords: micro fabrication, 3d acoustic streaming flow visualization, micro-particle image velocimetry, mixing enhancement
Procedia PDF Downloads 231518 Optimization of Rehabilitation in Scapolohumeral Periarthrosis Using Botulinum Toxin
Authors: M. A. Akulov, V. O. Zaharov, A. A. Tomskij
Abstract:
Introduction: Scapulohumeral periarthrosis, resulting as a reaction to mechanical injury of shoulder tendons and muscles, is associated with high incidence of temporal and permanent disability. There is a strong need for investigation of treatment of that patient group. Severe pain leads to limitation of movements range, which result in secondary alterations of joint capsule and ligamentous apparatus. Muscle tension and edema, swelling of fascial and fibrous structures result in nerve and vascular compression in intramuscular and osseo-muscular-fibrous spaces. Botulinum toxin injection leads to decrease of muscle tone, increase of movements range and associated pain alleviation. Study aim: Optimization of rehabilitation process in scapolohumeral periarthrosis using Xeomin. Patients and methods: 40 patients aged 37-56 years with scapulohumeral periarthrosis were evaluated. Patients were divided into two groups according to treatment regimen. The first (main) group included 21 patients, receiving intramuscular Xeomin 150-200 U in the area of brachio-scapular joint and trigger points (inducing motion range limitation and pain). Treatment procedures were combined with physical therapy and osteopathic procedures. The second (control) group included 19 patients, receiving conventional physical therapy and osteopathic procedures. The evaluation and efficacy comparison was carried out using McGill pain questionnaire, Clinical Global Impression scale (CGI), and patient-reported increase of brachio-scapular joint movement range and pain decrease at 1, 3 and 6 months of treatment. Results. The study demonstrated a significant improvement in the main group after one month of treatment, which persisted during months of treatment. At baseline, rank pain index on McGill pain questionnaire was 18,4±4,9 and 17,8±5,1 in the main and control group, respectively (p > 0,05). At 1 month of treatment we observed a significant decrease of pain syndrome (no pain or modest pain) and increase of movement range in angular degrees in the main group (р < 0,05). In the control group significant improvements were observed only on the 3 month of treatment (р < 0,05), but at 6 months of treatment the improvement in pain syndrome and motion range in brachio-scapular joint was significantly smaller, than in the main group. Rank pain index on McGill pain scale was 5,2±1,8 in the main group compared to 12,0±2,6 in the control group (р < 0,05). At 6 months of treatment patients in the first group reported a significant/highly significant improvement of general health on CGI, whereas in the second group most patients reported a minimal improvement. We observed a sustained and persistent improvement of motion range in brachio-scapular joint in the main group. Conclusion: Xeomin injections as a part of rehabilitation process in scapulohumeral periarthrosis lead to reduced time and increased quality of rehabilitation.Keywords: botulinum toxin, rehabilitation, scapulohumeral periarthrosis
Procedia PDF Downloads 2791517 Astronomical Object Classification
Authors: Alina Muradyan, Lina Babayan, Arsen Nanyan, Gohar Galstyan, Vigen Khachatryan
Abstract:
We present a photometric method for identifying stars, galaxies and quasars in multi-color surveys, which uses a library of ∼> 65000 color templates for comparison with observed objects. The method aims for extracting the information content of object colors in a statistically correct way, and performs a classification as well as a redshift estimation for galaxies and quasars in a unified approach based on the same probability density functions. For the redshift estimation, we employ an advanced version of the Minimum Error Variance estimator which determines the redshift error from the redshift dependent probability density function itself. The method was originally developed for the Calar Alto Deep Imaging Survey (CADIS), but is now used in a wide variety of survey projects. We checked its performance by spectroscopy of CADIS objects, where the method provides high reliability (6 errors among 151 objects with R < 24), especially for the quasar selection, and redshifts accurate within σz ≈ 0.03 for galaxies and σz ≈ 0.1 for quasars. For an optimization of future survey efforts, a few model surveys are compared, which are designed to use the same total amount of telescope time but different sets of broad-band and medium-band filters. Their performance is investigated by Monte-Carlo simulations as well as by analytic evaluation in terms of classification and redshift estimation. If photon noise were the only error source, broad-band surveys and medium-band surveys should perform equally well, as long as they provide the same spectral coverage. In practice, medium-band surveys show superior performance due to their higher tolerance for calibration errors and cosmic variance. Finally, we discuss the relevance of color calibration and derive important conclusions for the issues of library design and choice of filters. The calibration accuracy poses strong constraints on an accurate classification, which are most critical for surveys with few, broad and deeply exposed filters, but less severe for surveys with many, narrow and less deep filters.Keywords: VO, ArVO, DFBS, FITS, image processing, data analysis
Procedia PDF Downloads 801516 Seminal Attributes, Cooling Procedure and Post Thaw Quality of Semen of Indigenous Khari Bucks (Capra hircus) of Nepal
Authors: Pankaj Kumar Jha, Saroj Sapkota, Dil Bahadur Gurung, Raju Kadel, Neena Amatya Gorkhali, Bhola Shankar Shrestha
Abstract:
The study was conducted to evaluate the seminal attributes, effectiveness of cooling process and post-thawed semen quality of a Nepalese indigenous Khari buck. Thirty-two ejaculates, 16 from each buck were studied for seminal attributes of fresh semen: volume, color, mass activity, motility, viability, sperm concentration, and morphology. The pooled mean values for each seminal attributes were: volume 0.7±0.3 ml; colour 3.1±0.3 (milky white); mass activity 3.8±0.4 (rapid wave motion with formation of eddies at the end of waves to very rapid wave motion with distinct eddies formation); sperm motility 80.9±5.6%; sperm viability 94.6±2.0%; sperm concentration 2597.0±406.8x106/ml; abnormal acrosome, mid-piece and tail 10.7±1.8% and abnormal head 5±1.7%. For freezing semen, further 6 ejaculates from each buck were studied with Tris based egg yolk citrate extender. The pooled mean values of motility and viability of post diluted semen for 90 and 120 minutes each for cooling and glycerol equilibration were 73.8±4.8%, 88.1±2.6% and 69.2±6.0%, 85.0±1.7%, respectively. The pooled mean values of post thaw motility and viability with advancement of preservation time were: 0hour 49.0±4.6%, 81.2±1.9%; 2nd day 41±2.2%, 79±1%; 5th day 41±2.2%, 78.6±0.9% and 10th day 41±2.2%, 78.6±0.9%. We concluded from the above study that the seminal attributes and results of post-thaw semen quality were satisfactory and in accordance with other work in foreign countries, which indicated the feasibility of cryopreserving buck semen. For more validation, research with large number of bucks, different types of diluents and freezing trials by removing seminal plasma followed by pregnancy rate is recommended.Keywords: cryopreservation, Nepalese indigenous Khari (Hill goat) buck, post-thaw semen quality, seminal attributes
Procedia PDF Downloads 4031515 Hyperelastic Constitutive Modelling of the Male Pelvic System to Understand the Prostate Motion, Deformation and Neoplasms Location with the Influence of MRI-TRUS Fusion Biopsy
Authors: Muhammad Qasim, Dolors Puigjaner, Josep Maria López, Joan Herrero, Carme Olivé, Gerard Fortuny
Abstract:
Computational modeling of the human pelvis using the finite element (FE) method has become extremely important to understand the mechanics of prostate motion and deformation when transrectal ultrasound (TRUS) guided biopsy is performed. The number of reliable and validated hyperelastic constitutive FE models of the male pelvis region is limited, and given models did not precisely describe the anatomical behavior of pelvis organs, mainly of the prostate and its neoplasms location. The motion and deformation of the prostate during TRUS-guided biopsy makes it difficult to know the location of potential lesions in advance. When using this procedure, practitioners can only provide roughly estimations for the lesions locations. Consequently, multiple biopsy samples are required to target one single lesion. In this study, the whole pelvis model (comprised of the rectum, bladder, pelvic muscles, prostate transitional zone (TZ), and peripheral zone (PZ)) is used for the simulation results. An isotropic hyperelastic approach (Signorini model) was used for all the soft tissues except the vesical muscles. The vesical muscles are assumed to have a linear elastic behavior due to the lack of experimental data to determine the constants involved in hyperelastic models. The tissues and organ geometry is taken from the existing literature for 3D meshes. Then the biomechanical parameters were obtained under different testing techniques described in the literature. The acquired parametric values for uniaxial stress/strain data are used in the Signorini model to see the anatomical behavior of the pelvis model. The five mesh nodes in terms of small prostate lesions are selected prior to biopsy and each lesion’s final position is targeted when TRUS probe force of 30 N is applied at the inside rectum wall. Code_Aster open-source software is used for numerical simulations. Moreover, the overall effects of pelvis organ deformation were demonstrated when TRUS–guided biopsy is induced. The deformation of the prostate and neoplasms displacement showed that the appropriate material properties to organs altered the resulting lesion's migration parametrically. As a result, the distance traveled by these lesions ranged between 3.77 and 9.42 mm. The lesion displacement and organ deformation are compared and analyzed with our previous study in which we used linear elastic properties for all pelvic organs. Furthermore, the visual comparison of axial and sagittal slices are also compared, which is taken for Magnetic Resource Imaging (MRI) and TRUS images with our preliminary study.Keywords: code-aster, magnetic resonance imaging, neoplasms, transrectal ultrasound, TRUS-guided biopsy
Procedia PDF Downloads 871514 A Research on the Effect of Soil-Structure Interaction on the Dynamic Response of Symmetrical Reinforced Concrete Buildings
Authors: Adinew Gebremeskel Tizazu
Abstract:
The effect of soil-structure interaction on the dynamic response of reinforced concrete buildings of regular and symmetrical geometry are considered in this study. The structures are presumed to be generally embedded in a homogenous soil formation underlain by very stiff material or bedrock. The structure-foundation–soil system is excited at the base by an earthquake ground motion. The superstructure is idealized as a system with lumped masses concentrated at the floor levels, and coupled with the substructure. The substructure system, which comprises of the foundation and soil, is represented, and replaced by springs and dashpots. Frequency-dependent impedances of the foundation system are incorporated in the discrete model in terms of the springs and dashpots coefficients. The excitation applied to the model is field ground motions of actual earthquake records. Modal superposition principle is employed to transform the equations of motion in geometrical coordinates to modal coordinates. However, the modal equations remain coupled with respect to damping terms due to the difference in damping mechanisms of the superstructure and the soil. Hence, proportional damping for the coupled structural system may not be assumed. An iterative approach is adopted and programmed to solve the system of coupled equations of motion in modal coordinates to obtain the displacement responses of the system. Parametric studies for responses of building structures with regular and symmetric plans of different structural properties and heights are made for fixed and flexible base conditions, for different soil conditions encountered in Addis Ababa. The displacement, base shear and base overturning moments are used in the comparison of different types of structures for various foundation embedment depths, site conditions and height of structures. These values are compared against those of fixed base structure. The study shows that the flexible base structures, generally exhibit different responses from those structures with fixed base. Basically, the natural circular frequencies, the base shears and the inter-story displacements for the flexible base are less than those of the fixed base structures. This trend is particularly evident when the flexible soil has large thickness. In contrast, the trend becomes less predictable, when the thickness of the flexible soil decreases. Moreover, in the latter case, the iteration undulates significantly making the prediction difficult. This is attributed to the highly jagged nature of the impedance functions of frequencies for such formations. In this case, it is difficult to conclude whether the conventional fixed-base approach yields conservative design forces, as is the case for soil formations of large thickness.Keywords: effect of soil structure, dynamic response corroborated, the modal superposition principle, parametric studies
Procedia PDF Downloads 351513 Size Effects on Structural Performance of Concrete Gravity Dams
Authors: Mehmet Akköse
Abstract:
Concern about seismic safety of concrete dams have been growing around the world, partly because the population at risk in locations downstream of major dams continues to expand and also because it is increasingly evident that the seismic design concepts in use at the time most existing dams were built were inadequate. Most of the investigations in the past have been conducted on large dams, typically above 100m high. A large number of concrete dams in our country and in other parts of the world are less than 50m high. Most of these dams were usually designed using pseudo-static methods, ignoring the dynamic characteristics of the structure as well as the characteristics of the ground motion. Therefore, it is important to carry out investigations on seismic behavior this category of dam in order to assess and evaluate the safety of existing dams and improve the knowledge for different high dams to be constructed in the future. In this study, size effects on structural performance of concrete gravity dams subjected to near and far-fault ground motions are investigated including dam-water-foundation interaction. For this purpose, a benchmark problem proposed by ICOLD (International Committee on Large Dams) is chosen as a numerical application. Structural performance of the dam having five different heights is evaluated according to damage criterions in USACE (U.S. Army Corps of Engineers). It is decided according to their structural performance if non-linear analysis of the dams requires or not. The linear elastic dynamic analyses of the dams to near and far-fault ground motions are performed using the step-by-step integration technique. The integration time step is 0.0025 sec. The Rayleigh damping constants are calculated assuming 5% damping ratio. The program NONSAP modified for fluid-structure systems with the Lagrangian fluid finite element is employed in the response calculations.Keywords: concrete gravity dams, Lagrangian approach, near and far-fault ground motion, USACE damage criterions
Procedia PDF Downloads 2671512 Elucidation of Dynamics of Murine Double Minute 2 Shed Light on the Anti-cancer Drug Development
Authors: Nigar Kantarci Carsibasi
Abstract:
Coarse-grained elastic network models, namely Gaussian network model (GNM) and Anisotropic network model (ANM), are utilized in order to investigate the fluctuation dynamics of Murine Double Minute 2 (MDM2), which is the native inhibitor of p53. Conformational dynamics of MDM2 are elucidated in unbound, p53 bound, and non-peptide small molecule inhibitor bound forms. With this, it is aimed to gain insights about the alterations brought to global dynamics of MDM2 by native peptide inhibitor p53, and two small molecule inhibitors (HDM201 and NVP-CGM097) that are undergoing clinical stages in cancer studies. MDM2 undergoes significant conformational changes upon inhibitor binding, carrying pieces of evidence of induced-fit mechanism. Small molecule inhibitors examined in this work exhibit similar fluctuation dynamics and characteristic mode shapes with p53 when complexed with MDM2, which would shed light on the design of novel small molecule inhibitors for cancer therapy. The results showed that residues Phe 19, Trp 23, Leu 26 reside in the minima of slowest modes of p53, pointing to the accepted three-finger binding model. Pro 27 displays the most significant hinge present in p53 and comes out to be another functionally important residue. Three distinct regions are identified in MDM2, for which significant conformational changes are observed upon binding. Regions I (residues 50-77) and III (residues 90-105) correspond to the binding interface of MDM2, including (α2, L2, and α4), which are stabilized during complex formation. Region II (residues 77-90) exhibits a large amplitude motion, being highly flexible, both in the absence and presence of p53 or other inhibitors. MDM2 exhibits a scattered profile in the fastest modes of motion, while binding of p53 and inhibitors puts restraints on MDM2 domains, clearly distinguishing the kinetically hot regions. Mode shape analysis revealed that the α4 domain controls the size of the cleft by keeping the cleft narrow in unbound MDM2; and open in the bound states for proper penetration and binding of p53 and inhibitors, which points to the induced-fit mechanism of p53 binding. P53 interacts with α2 and α4 in a synchronized manner. Collective modes are shifted upon inhibitor binding, i.e., second mode characteristic motion in MDM2-p53 complex is observed in the first mode of apo MDM2; however, apo and bound MDM2 exhibits similar features in the softest modes pointing to pre-existing modes facilitating the ligand binding. Although much higher amplitude motions are attained in the presence of non-peptide small molecule inhibitor molecules as compared to p53, they demonstrate close similarity. Hence, NVP-CGM097 and HDM201 succeed in mimicking the p53 behavior well. Elucidating how drug candidates alter the MDM2 global and conformational dynamics would shed light on the rational design of novel anticancer drugs.Keywords: cancer, drug design, elastic network model, MDM2
Procedia PDF Downloads 1301511 Quantitative Analysis of Camera Setup for Optical Motion Capture Systems
Authors: J. T. Pitale, S. Ghassab, H. Ay, N. Berme
Abstract:
Biomechanics researchers commonly use marker-based optical motion capture (MoCap) systems to extract human body kinematic data. These systems use cameras to detect passive or active markers placed on the subject. The cameras use triangulation methods to form images of the markers, which typically require each marker to be visible by at least two cameras simultaneously. Cameras in a conventional optical MoCap system are mounted at a distance from the subject, typically on walls, ceiling as well as fixed or adjustable frame structures. To accommodate for space constraints and as portable force measurement systems are getting popular, there is a need for smaller and smaller capture volumes. When the efficacy of a MoCap system is investigated, it is important to consider the tradeoff amongst the camera distance from subject, pixel density, and the field of view (FOV). If cameras are mounted relatively close to a subject, the area corresponding to each pixel reduces, thus increasing the image resolution. However, the cross section of the capture volume also decreases, causing reduction of the visible area. Due to this reduction, additional cameras may be required in such applications. On the other hand, mounting cameras relatively far from the subject increases the visible area but reduces the image quality. The goal of this study was to develop a quantitative methodology to investigate marker occlusions and optimize camera placement for a given capture volume and subject postures using three-dimension computer-aided design (CAD) tools. We modeled a 4.9m x 3.7m x 2.4m (LxWxH) MoCap volume and designed a mounting structure for cameras using SOLIDWORKS (Dassault Systems, MA, USA). The FOV was used to generate the capture volume for each camera placed on the structure. A human body model with configurable posture was placed at the center of the capture volume on CAD environment. We studied three postures; initial contact, mid-stance, and early swing. The human body CAD model was adjusted for each posture based on the range of joint angles. Markers were attached to the model to enable a full body capture. The cameras were placed around the capture volume at a maximum distance of 2.7m from the subject. We used the Camera View feature in SOLIDWORKS to generate images of the subject as seen by each camera and the number of markers visible to each camera was tabulated. The approach presented in this study provides a quantitative method to investigate the efficacy and efficiency of a MoCap camera setup. This approach enables optimization of a camera setup through adjusting the position and orientation of cameras on the CAD environment and quantifying marker visibility. It is also possible to compare different camera setup options on the same quantitative basis. The flexibility of the CAD environment enables accurate representation of the capture volume, including any objects that may cause obstructions between the subject and the cameras. With this approach, it is possible to compare different camera placement options to each other, as well as optimize a given camera setup based on quantitative results.Keywords: motion capture, cameras, biomechanics, gait analysis
Procedia PDF Downloads 3101510 Two-Dimensional Dynamics Motion Simulations of F1 Rare Wing-Flap
Authors: Chaitanya H. Acharya, Pavan Kumar P., Gopalakrishna Narayana
Abstract:
In the realm of aerodynamics, numerous vehicles incorporate moving components to enhance their performance. For instance, airliners deploy hydraulically operated flaps and ailerons during take-off and landing, while Formula 1 racing cars utilize hydraulic tubes and actuators for various components, including the Drag Reduction System (DRS). The DRS, consisting of a rear wing and adjustable flaps, plays a crucial role in overtaking manoeuvres. The DRS has two positions: the default position with the flaps down, providing high downforce, and the lifted position, which reduces drag, allowing for increased speed and aiding in overtaking. Swift deployment of the DRS during races is essential for overtaking competitors. The fluid flow over the rear wing flap becomes intricate during deployment, involving flow reversal and operational changes, leading to unsteady flow physics that significantly influence aerodynamic characteristics. Understanding the drag and downforce during DRS deployment is crucial for determining race outcomes. While experiments can yield accurate aerodynamic data, they can be expensive and challenging to conduct across varying speeds. Computational Fluid Dynamics (CFD) emerges as a cost-effective solution to predict drag and downforce across a range of speeds, especially with the rapid deployment of the DRS. This study employs the finite volume-based solver Ansys Fluent, incorporating dynamic mesh motions and a turbulent model to capture the complex flow phenomena associated with the moving rear wing flap. A dedicated section for the rare wing-flap is considered in the present simulations, and the aerodynamics of these sections closely resemble S1223 aerofoils. Before delving into the simulations of the rare wing-flap aerofoil, numerical results undergo validation using experimental data from an NLR flap aerofoil case, encompassing different flap angles at two distinct angles of attack was carried out. The increase in flap angle as increase in lift and drag is observed for a given angle of attack. The simulation methodology for the rare-wing-flap aerofoil case involves specific time durations before lifting the flap. During this period, drag and downforce values are determined as 330 N and 1800N, respectively. Following the flap lift, a noteworthy reduction in drag to 55 % and a decrease in downforce to 17 % are observed. This understanding is critical for making instantaneous decisions regarding the deployment of the Drag Reduction System (DRS) at specific speeds, thereby influencing the overall performance of the Formula 1 racing car. Hence, this work emphasizes the utilization of dynamic mesh motion methodology to predict the aerodynamic characteristics during the deployment of the DRS in a Formula 1 racing car.Keywords: DRS, CFD, drag, downforce, dynamics mesh motion
Procedia PDF Downloads 951509 A Modified Open Posterior Approach for the Fixation of Posterior Cruciate Ligament Tibial Avulsion Fractures
Authors: Babak Mirzashahi, Arvin Najafi, Pejman Mansouri, Mahmoud Farzan
Abstract:
Background: The most effective treatment of posterior cruciate ligament (PCL) tears and the consequence of untreated PCL injuries remain controversial. Objectives: The aim of this study is to assess outcomes of fixation of tibial posterior cruciate ligament (PCL) avulsion fractures via a modified technique. Patients and Methods: From January, 2009 to March, 2012, there were 45 cases of PCL tibial avulsion fractures that were referred to our hospital and were managed through a modified open posterior approach. Fixation of Tibial PCL avulsion fractures were fixed by means of a lag screw and washer placed through our modified open posterior approach. Range of motion was begun on the first postoperative day. Clinical stability, range of motion, gastrocnemius muscle strength, radiographic investigation, and patient’s overall quality of life was analyzed at final follow up visit. Results: The average of overall musculoskeletal functional evaluation scores was 15 (range 3–35). All patients achieved union of their fracture and had clinically stable knees at the latest follow-up. The mean preoperative Lysholm score for 15 knees was 62 ± 8 (range, 50-75); the mean postoperative Lysholm score was 92± 7 (range, 75-101). A significant difference in Lysholm scores between preoperative and final follow-up evaluations was found (P < .05). At first-year follow-up, 42 (93%) patients revealed a difference of less than 10 mm in thigh circumference between their injured and healthy knees. Conclusions: The management of displaced large PCL avulsion fractures with placement of a cancellous lag screw with washer by means of the modified open posterior approach leads to satisfactory clinical, radiographic, and functional results and reduces the operation time and less blood loss. Level of evidence: IV.Keywords: posterior cruciate ligament, tibial fracture, lysholm knee score, patient outcome assessment
Procedia PDF Downloads 3011508 Innovative Technologies of Distant Spectral Temperature Control
Authors: Leonid Zhukov, Dmytro Petrenko
Abstract:
Optical thermometry has no alternative in many cases of industrial most effective continuous temperature control. Classical optical thermometry technologies can be used on available for pyrometers controlled objects with stable radiation characteristics and transmissivity of the intermediate medium. Without using temperature corrections, it is possible in the case of a “black” body for energy pyrometry and the cases of “black” and “grey” bodies for spectral ratio pyrometry or with using corrections – for any colored bodies. Consequently, with increasing the number of operating waves, optical thermometry possibilities to reduce methodical errors significantly expand. That is why, in recent 25-30 years, research works have been reoriented on more perfect spectral (multicolor) thermometry technologies. There are two physical material substances, i.e., substance (controlled object) and electromagnetic field (thermal radiation), to be operated in optical thermometry. Heat is transferred by radiation; therefore, radiation has the energy, entropy, and temperature. Optical thermometry was originating simultaneously with the developing of thermal radiation theory when the concept and the term "radiation temperature" was not used, and therefore concepts and terms "conditional temperatures" or "pseudo temperature" of controlled objects were introduced. They do not correspond to the physical sense and definitions of temperature in thermodynamics, molecular-kinetic theory, and statistical physics. Launched by the scientific thermometric society, discussion about the possibilities of temperature measurements of objects, including colored bodies, using the temperatures of their radiation is not finished. Are the information about controlled objects transferred by their radiation enough for temperature measurements? The positive and negative answers on this fundamental question divided experts into two opposite camps. Recent achievements of spectral thermometry develop events in her favour and don’t leave any hope for skeptics. This article presents the results of investigations and developments in the field of spectral thermometry carried out by the authors in the Department of Thermometry and Physics-Chemical Investigations. The authors have many-year’s of experience in the field of modern optical thermometry technologies. Innovative technologies of optical continuous temperature control have been developed: symmetric-wave, two-color compensative, and based on obtained nonlinearity equation of spectral emissivity distribution linear, two-range, and parabolic. Тhe technologies are based on direct measurements of physically substantiated and proposed by Prof. L. Zhukov, radiation temperatures with the next calculation of the controlled object temperature using this radiation temperatures and corresponding mathematical models. Тhe technologies significantly increase metrological characteristics of continuous contactless and light-guide temperature control in energy, metallurgical, ceramic, glassy, and other productions. For example, under the same conditions, the methodical errors of proposed technologies are less than the errors of known spectral and classical technologies in 2 and 3-13 times, respectively. Innovative technologies provide quality products obtaining at the lowest possible resource-including energy costs. More than 600 publications have been published on the completed developments, including more than 100 domestic patents, as well as 34 patents in Australia, Bulgaria, Germany, France, Canada, the USA, Sweden, and Japan. The developments have been implemented in the enterprises of USA, as well as Western Europe and Asia, including Germany and Japan.Keywords: emissivity, radiation temperature, object temperature, spectral thermometry
Procedia PDF Downloads 991507 Rheological and Self-Healing Properties of Poly (Vinyl Butyral)
Authors: Sunatda Arayachukiat, Shogo Nobukawa, Masayuki Yamaguchi
Abstract:
A new self-healing material was developed utilizing molecular entanglements for poly(vinyl butyral) (PVB) containing plasticizers. It was found that PVB shows autonomic self-healing behavior even below the glass transition temperature Tg because of marked molecular motion at surface. Moreover, the plasticizer addition enhances the chain mobility, leading to good healing behavior.Keywords: Poly(vinyl butyral) (PVB), rheological properties, self-healing behaviour, molecular diffusion
Procedia PDF Downloads 4291506 RAFU Functions in Robotics and Automation
Authors: Alicia C. Sanchez
Abstract:
This paper investigates the implementation of RAFU functions (radical functions) in robotics and automation. Specifically, the main goal is to show how these functions may be useful in lane-keeping control and the lateral control of autonomous machines, vehicles, robots or the like. From the knowledge of several points of a certain route, the RAFU functions are used to achieve the lateral control purpose and maintain the lane-keeping errors within the fixed limits. The stability that these functions provide, their ease of approaching any continuous trajectory and the control of the possible error made on the approximation may be useful in practice.Keywords: automatic navigation control, lateral control, lane-keeping control, RAFU approximation
Procedia PDF Downloads 3031505 Effects of Modified Low-Dye Taping on First Ray Mobility Test and Sprint Time
Authors: Yu-Ju Tsai, Ching-Chun Wang, Wen-Tzu Tang, Huei-Ming Chai
Abstract:
A pronated foot is frequently associated with a hypermobile first ray, then developing further severe foot problems. Low-Dye taping with athletic tape has been widely used to restrict excessive first ray motion and re-build height of the medial longitudinal arch in general population with pronated foot. It is not the case, however, for sprinters since they feel too much restriction of foot motions. Currently, the kinesio tape, more elastic than the athletic tape, has been widely used to re-adjust joint positions. It was interesting whether modified low-Dye taping using kinesio tape was beneficial for altering first ray mobility and still giving enough arch support. The purpose of this study was to investigate the effect of modified low-Dye taping on first ray mobility test and 60-m sprint time for sprinters with pronated foot. The significance of this study provides new insight into a treatment alternative of modified low-Dye taping for sprinter with pronated foot. Ten young male sprinters, aged 20.8±1.6 years, with pronated foot were recruited for this study. The pronated foot was defined as the foot that the navicular drop test was greater than 1.0 cm. Three optic shutters were placed at the start, 30-m, and 60-m sites to record sprint time. All participants were asked to complete 3 trials of the 60-m dash with both taping and non-taping conditions in a random order. The low-Dye taping was applied using the method postulated by Ralph Dye in 1939 except the kinesio tape was used instead. All outcome variables were recorded for taping and non-taping conditions. Paired t-tests were used to analyze all outcome variables between 2 conditions. Although there were no statistically significant differences in dorsal and plantar mobility between taping and non-taping conditions, a statistical significance was found in a total range of motion (dorsiflexion plus plantarflexion angle) of the first ray when a modified low-Dye taping was applied (p < 0.05). Time to complete 60-m sprint was significantly increased with low-Dye taping (p < 0.05) while no significance was found for time to 30-m. it indicated that modified low-Dye taping changed maximum sprint speed of 60-m dash. Conclusively, modified low-Dye taping was capable of increasing first ray mobility and further altered maximum sprint speed.Keywords: first ray mobility, kinesio taping, pronated foot, sprint time
Procedia PDF Downloads 2771504 Identification of Failures Occurring on a System on Chip Exposed to a Neutron Beam for Safety Applications
Authors: S. Thomet, S. De-Paoli, F. Ghaffari, J. M. Daveau, P. Roche, O. Romain
Abstract:
In this paper, we present a hardware module dedicated to understanding the fail reason of a System on Chip (SoC) exposed to a particle beam. Impact of Single-Event Effects (SEE) on processor-based SoCs is a concern that has increased in the past decade, particularly for terrestrial applications with automotive safety increasing requirements, as well as consumer and industrial domains. The SEE created by the impact of a particle on an SoC may have consequences that can end to instability or crashes. Specific hardening techniques for hardware and software have been developed to make such systems more reliable. SoC is then qualified using cosmic ray Accelerated Soft-Error Rate (ASER) to ensure the Soft-Error Rate (SER) remains in mission profiles. Understanding where errors are occurring is another challenge because of the complexity of operations performed in an SoC. Common techniques to monitor an SoC running under a beam are based on non-intrusive debug, consisting of recording the program counter and doing some consistency checking on the fly. To detect and understand SEE, we have developed a module embedded within the SoC that provide support for recording probes, hardware watchpoints, and a memory mapped register bank dedicated to software usage. To identify CPU failure modes and the most important resources to probe, we have carried out a fault injection campaign on the RTL model of the SoC. Probes are placed on generic CPU registers and bus accesses. They highlight the propagation of errors and allow identifying the failure modes. Typical resulting errors are bit-flips in resources creating bad addresses, illegal instructions, longer than expected loops, or incorrect bus accesses. Although our module is processor agnostic, it has been interfaced to a RISC-V by probing some of the processor registers. Probes are then recorded in a ring buffer. Associated hardware watchpoints are allowing to do some control, such as start or stop event recording or halt the processor. Finally, the module is also providing a bank of registers where the firmware running on the SoC can log information. Typical usage is for operating system context switch recording. The module is connected to a dedicated debug bus and is interfaced to a remote controller via a debugger link. Thus, a remote controller can interact with the monitoring module without any intrusiveness on the SoC. Moreover, in case of CPU unresponsiveness, or system-bus stall, the recorded information can still be recovered, providing the fail reason. A preliminary version of the module has been integrated into a test chip currently being manufactured at ST in 28-nm FDSOI technology. The module has been triplicated to provide reliable information on the SoC behavior. As the primary application domain is automotive and safety, the efficiency of the module will be evaluated by exposing the test chip under a fast-neutron beam by the end of the year. In the meantime, it will be tested with alpha particles and electromagnetic fault injection (EMFI). We will report in the paper on fault-injection results as well as irradiation results.Keywords: fault injection, SoC fail reason, SoC soft error rate, terrestrial application
Procedia PDF Downloads 2301503 Energy Complementary in Colombia: Imputation of Dataset
Authors: Felipe Villegas-Velasquez, Harold Pantoja-Villota, Sergio Holguin-Cardona, Alejandro Osorio-Botero, Brayan Candamil-Arango
Abstract:
Colombian electricity comes mainly from hydric resources, affected by environmental variations such as the El Niño phenomenon. That is why incorporating other types of resources is necessary to provide electricity constantly. This research seeks to fill the wind speed and global solar irradiance dataset for two years with the highest amount of information. A further result is the characterization of the data by region that led to infer which errors occurred and offered the incomplete dataset.Keywords: energy, wind speed, global solar irradiance, Colombia, imputation
Procedia PDF Downloads 1461502 Comparative Study of Active Release Technique and Myofascial Release Technique in Patients with Upper Trapezius Spasm
Authors: Harihara Prakash Ramanathan, Daksha Mishra, Ankita Dhaduk
Abstract:
Relevance: This qualitative study will educate the clinician in putting into practice the advanced method of movement science in restoring the function. Purpose: The purpose of this study is to compare the effectiveness of Active Release Technique and myofascial release technique on range of motion, neck function and pain in patients with upper trapezius spasm. Methods/Analysis: The study was approved by the institutional Human Research and Ethics committee. This study included sixty patients of age group between 20 to 55 years with upper trapezius spasm. Patients were randomly divided into two groups receiving Active Release Technique (Group A) and Myofascial Release Technique (Group B). The patients were treated for 1 week and three outcome measures ROM, pain and functional level were measured using Goniometer, Visual analog scale(VAS), Neck disability Index Questionnaire(NDI) respectively. Paired Sample 't' test was used to compare the differences of pre and post intervention values of Cervical Range of motion, Neck disability Index, Visual analog scale of Group A and Group B. Independent't' test was used to compare the differences between two groups in terms of improvement in cervical range of motion, decrease in visual analogue scale(VAS), decrease in Neck disability index score. Results: Both the groups showed statistically significant improvements in cervical ROM, reduction in pain and in NDI scores. However, mean change in Cervical flexion, cervical extension, right side flexion, left side flexion, right side rotation, left side rotation, pain, neck disability level showed statistically significant improvement (P < 0. 05)) in the patients who received Active Release Technique as compared to Myofascial release technique. Discussion and conclusions: In present study, the average improvement immediately post intervention is significantly greater as compared to before treatment but there is even more improvement after seven sessions as compared to single session. Hence, this proves that several sessions of Manual techniques are necessary to produce clinically relevant results. Active release technique help to reduce the pain threshold by removing adhesion and promote normal tissue extensibility. The act of tensioning and compressing the affected tissue both with digital contact and through the active movement performed by the patient can be a plausible mechanism for tissue healing in this study. This study concluded that both Active Release Technique (ART) and Myofascial release technique (MFR) are equally effective in managing upper trapezius muscle spasm, but more improvement can be achieved by Active Release Technique (ART). Impact and Implications: Active Release Technique can be adopted as mainstay of treatment approach in treating trapezius spasm for faster relief and improving the functional status.Keywords: trapezius spasm, myofascial release, active release technique, pain
Procedia PDF Downloads 2741501 Study of Linear Generator for Vibration Energy Harvesting of Frequency more than 50Hz
Authors: Seong-Jin Cho, Jin Ho Kim
Abstract:
Energy harvesting is the technology which gathers and converts external energies such as light, vibration and heat which are disposed into reusable electrical energy and uses such electrical energy. The vibration energy harvesting is very interesting technology because it produces very high density of energy and unaffected by the climate. Vibration energy can be harvested by the electrostatic, electromagnetic and piezoelectric systems. The electrostatic system has low energy conversion efficiency, and the piezoelectric system is expensive and needs the frequent maintenance because it is made of piezoelectric ceramic. On the other hand, the electromagnetic system has a long life time and high harvesting efficiency, and it is relatively cheap. The electromagnetic harvesting system includes the linear generator and the rotary-type generator. The rotary-type generators require the additional mechanical conversion device if it uses linear motion of vibration. But, the linear generator uses directly linear motion of vibration without a mechanical conversion device, and it has uncomplicated structure and light weight compared with the rotary-type generator. Therefore, the linear electromagnetic generator can be useful in using vibration energy harvesting. The pole transformer systems need electricity sensor system for sending voltage and power information to administrator. Therefore, the battery is essential, and its regular maintenance of replacement is required. In case of the transformer of high location in mountainous areas, the person can’t easily access it resulting in high maintenance cost. To overcome these problems, we designed and developed the linear electromagnetic generator which can replace battery in electricity sensor system for sending voltage and power information of the pole transformer. And, it uses vibration energy of frequency more than 50 Hz by the pole transformer. In order to analyze the electromagnetic characteristics of small linear electric generator, a commercial electromagnetic finite element analysis program "MAXWELL" was used. Then, through the actual production and experiment of linear generator, we confirmed output power of linear generator.Keywords: energy harvesting, frequency, linear generator, experiment
Procedia PDF Downloads 2601500 Comparative Study of Skeletonization and Radial Distance Methods for Automated Finger Enumeration
Authors: Mohammad Hossain Mohammadi, Saif Al Ameri, Sana Ziaei, Jinane Mounsef
Abstract:
Automated enumeration of the number of hand fingers is widely used in several motion gaming and distance control applications, and is discussed in several published papers as a starting block for hand recognition systems. The automated finger enumeration technique should not only be accurate, but also must have a fast response for a moving-picture input. The high performance of video in motion games or distance control will inhibit the program’s overall speed, for image processing software such as Matlab need to produce results at high computation speeds. Since an automated finger enumeration with minimum error and processing time is desired, a comparative study between two finger enumeration techniques is presented and analyzed in this paper. In the pre-processing stage, various image processing functions were applied on a real-time video input to obtain the final cleaned auto-cropped image of the hand to be used for the two techniques. The first technique uses the known morphological tool of skeletonization to count the number of skeleton’s endpoints for fingers. The second technique uses a radial distance method to enumerate the number of fingers in order to obtain a one dimensional hand representation. For both discussed methods, the different steps of the algorithms are explained. Then, a comparative study analyzes the accuracy and speed of both techniques. Through experimental testing in different background conditions, it was observed that the radial distance method was more accurate and responsive to a real-time video input compared to the skeletonization method. All test results were generated in Matlab and were based on displaying a human hand for three different orientations on top of a plain color background. Finally, the limitations surrounding the enumeration techniques are presented.Keywords: comparative study, hand recognition, fingertip detection, skeletonization, radial distance, Matlab
Procedia PDF Downloads 3821499 Forensic Detection of Errors Permitted by the Witnesses in Their Testimony
Authors: Lev Bertovsky
Abstract:
The purpose of this study was to determine the reasons for the formation of false testimony from witnesses and make recommendations on the recognition of such cases. During the studies, which were based on the achievements of professionals in the field of psychology, as well as personal investigative practice, the stages of perception of the information were studied, as well as the process of its reclaim from the memory and transmission to the communicator upon request. Based on the principles of the human brain, kinds of conscientious witness mistakes were systematized. Proposals were formulated for the optimization of investigative actions in cases where the witnesses make an honest mistake with respect to the effects previously observed by them.Keywords: criminology, eyewitness testimony, honest mistake, information, investigator, investigation, questioning
Procedia PDF Downloads 1861498 A Comparison of Two and Three Dimensional Motion Capture Methodologies in the Analysis of Underwater Fly Kicking Kinematics
Authors: Isobel M. Thompson, Dorian Audot, Dominic Hudson, Martin Warner, Joseph Banks
Abstract:
Underwater fly kick is an essential skill in swimming, which can have a considerable impact upon overall race performance in competition, especially in sprint events. Reduced wave drags acting upon the body under the surface means that the underwater fly kick will potentially be the fastest the swimmer is travelling throughout the race. It is therefore critical to understand fly kicking techniques and determining biomechanical factors involved in the performance. Most previous studies assessing fly kick kinematics have focused on two-dimensional analysis; therefore, the three-dimensional elements of the underwater fly kick techniques are not well understood. Those studies that have investigated fly kicking techniques using three-dimensional methodologies have not reported full three-dimensional kinematics for the techniques observed, choosing to focus on one or two joints. There has not been a direct comparison completed on the results obtained using two-dimensional and three-dimensional analysis, and how these different approaches might affect the interpretation of subsequent results. The aim of this research is to quantify the differences in kinematics observed in underwater fly kicks obtained from both two and three-dimensional analyses of the same test conditions. In order to achieve this, a six-camera underwater Qualisys system was used to develop an experimental methodology suitable for assessing the kinematics of swimmer’s starts and turns. The cameras, capturing at a frequency of 100Hz, were arranged along the side of the pool spaced equally up to 20m creating a capture volume of 7m x 2m x 1.5m. Within the measurement volume, error levels were estimated at 0.8%. Prior to pool trials, participants completed a landside calibration in order to define joint center locations, as certain markers became occluded once the swimmer assumed the underwater fly kick position in the pool. Thirty-four reflective markers were placed on key anatomical landmarks, 9 of which were then removed for the pool-based trials. The fly-kick swimming conditions included in the analysis are as follows: maximum effort prone, 100m pace prone, 200m pace prone, 400m pace prone, and maximum pace supine. All trials were completed from a push start to 15m to ensure consistent kick cycles were captured. Both two-dimensional and three-dimensional kinematics are calculated from joint locations, and the results are compared. Key variables reported include kick frequency and kick amplitude, as well as full angular kinematics of the lower body. Key differences in these variables obtained from two-dimensional and three-dimensional analysis are identified. Internal rotation (up to 15º) and external rotation (up to -28º) were observed using three-dimensional methods. Abduction (5º) and adduction (15º) were also reported. These motions are not observed in the two-dimensional analysis. Results also give an indication of different techniques adopted by swimmers at various paces and orientations. The results of this research provide evidence of the strengths of both two dimensional and three dimensional motion capture methods in underwater fly kick, highlighting limitations which could affect the interpretation of results from both methods.Keywords: swimming, underwater fly kick, performance, motion capture
Procedia PDF Downloads 1361497 Traverse Surveying Table Simple and Sure
Authors: Hamid Fallah
Abstract:
Creating surveying stations is the first thing that a surveyor learns; they can use it for control and implementation in projects such as buildings, roads, tunnels, monitoring, etc., whatever is related to the preparation of maps. In this article, the method of calculation through the traverse table and by checking several examples of errors of several publishers of surveying books in the calculations of this table, we also control the results of several software in a simple way. Surveyors measure angles and lengths in creating surveying stations, so the most important task of a surveyor is to be able to correctly remove the error of angles and lengths from the calculations and to determine whether the amount of error is within the permissible limit for delete it or not.Keywords: UTM, localization, scale factor, cartesian, traverse
Procedia PDF Downloads 831496 Factors Associated with Increase of Diabetic Foot Ulcers in Diabetic Patients in Nyahururu County Hospital
Authors: Daniel Wachira
Abstract:
The study aims to determine factors contributing to increasing rates of DFU among DM patients attending clinics in Nyahururu County referral hospital, Lakipia County. The study objectives include;- To determine the demographic factors contributing to increased rates of DFU among DM patients, determining the sociocultural factors that contribute to increased rates of DFU among DM patients and determining the health facility factors contributing to increased rates of DFU among DM patients attending DM clinic at Nyahururu county referral hospital, Laikipia County. This study will adopt a descriptive cross-sectional study design. It involves the collection of data at a one-time point without follow-up. This method is fast and inexpensive, there is no loss to follow up as the data is collected at one time point and associations between variables can be determined. The study population includes all DM patients with or without DFU. The sampling technique that will be used is the probability sampling method, a simple random method of sampling will be used. The study will employ the use of questionnaires to collect the required information. Questionnaires will be a research administered questionnaires. The questionnaire developed was done in consultation with other research experts (supervisor) to ensure reliability. The questionnaire designed will be pre-tested by hand delivering them to a sample 10% of the sample size at J.M Kariuki Memorial hospital, Nyandarua county and thereafter collecting them dully filled followed by refining of errors to ensure it is valid for collection of data relevant for this study. Refining of errors on the questionnaires to ensure it was valid for collection of data relevant for this study. Data collection will begin after the approval of the project. Questionnaires will be administered only to the participants who met the selection criteria by the researcher and those who agreed to participate in the study to collect key information with regard to the objectives of the study. The study's authority will be obtained from the National Commission of Science and Technology and Innovation. Permission will also be obtained from the Nyahururu County referral hospital administration staff. The purpose of the study will be explained to the respondents in order to secure informed consent, and no names will be written on the questionnaires. All the information will be treated with maximum confidentiality by not disclosing who the respondent was and the information.Keywords: diabetes, foot ulcer, social factors, hospital factors
Procedia PDF Downloads 231495 Basic Calibration and Normalization Techniques for Time Domain Reflectometry Measurements
Authors: Shagufta Tabassum
Abstract:
The study of dielectric properties in a binary mixture of liquids is very useful to understand the liquid structure, molecular interaction, dynamics, and kinematics of the mixture. Time-domain reflectometry (TDR) is a powerful tool for studying the cooperation and molecular dynamics of the H-bonded system. In this paper, we discuss the basic calibration and normalization procedure for time-domain reflectometry measurements. Our approach is to explain the different types of error occur during TDR measurements and how these errors can be eliminated or minimized.Keywords: time domain reflectometry measurement techinque, cable and connector loss, oscilloscope loss, and normalization technique
Procedia PDF Downloads 2071494 A Comparative Study on Vowel Articulation in Malayalam Speaking Children Using Cochlear Implant
Authors: Deepthy Ann Joy, N. Sreedevi
Abstract:
Hearing impairment (HI) at an early age, identified before the onset of language development can reduce the negative effect on speech and language development of children. Early rehabilitation is very important in the improvement of speech production in children with HI. Other than conventional hearing aids, Cochlear Implants are being used in the rehabilitation of children with HI. However, delay in acquisition of speech and language milestones persist in children with Cochlear Implant (CI). Delay in speech milestones are reflected through speech sound errors. These errors reflect the temporal and spectral characteristics of speech. Hence, acoustical analysis of the speech sounds will provide a better representation of speech production skills in children with CI. The present study aimed at investigating the acoustic characteristics of vowels in Malayalam speaking children with a cochlear implant. The participants of the study consisted of 20 Malayalam speaking children in the age range of four and seven years. The experimental group consisted of 10 children with CI, and the control group consisted of 10 typically developing children. Acoustic analysis was carried out for 5 short (/a/, /i/, /u/, /e/, /o/) and 5 long vowels (/a:/, /i:/, /u:/, /e:/, /o:/) in word-initial position. The responses were recorded and analyzed for acoustic parameters such as Vowel duration, Ratio of the duration of a short and long vowel, Formant frequencies (F₁ and F₂) and Formant Centralization Ratio (FCR) computed using the formula (F₂u+F₂a+F₁i+F₁u)/(F₂i+F₁a). Findings of the present study indicated that the values for vowel duration were higher in experimental group compared to the control group for all the vowels except for /u/. Ratio of duration of short and long vowel was also found to be higher in experimental group compared to control group except for /i/. Further F₁ for all vowels was found to be higher in experimental group with variability noticed in F₂ values. FCR was found be higher in experimental group, indicating vowel centralization. Further, the results of independent t-test revealed no significant difference across the parameters in both the groups. It was found that the spectral and temporal measures in children with CI moved towards normal range. The result emphasizes the significance of early rehabilitation in children with hearing impairment. The role of rehabilitation related aspects are also discussed in detail which can be clinically incorporated for the betterment of speech therapeutic services in children with CI.Keywords: acoustics, cochlear implant, Malayalam, vowels
Procedia PDF Downloads 144