Search results for: full scale measurement
9685 The Interactive Effects among Supervisor Support, Academic Emotion, and Positive Mental Health: An Evidence Based on Longitudinal Cross-Lagged Panel Data Analysis on Postgraduates in China
Authors: Jianzhou Ni, Hua Fan
Abstract:
It has been determined that supervisor support has a major influence on postgraduate students' academic emotions and is considered a method of successfully anticipating postgraduates' good psychological well-being levels. As a result, by assessing the mediating influence upon academic emotions for contemporary postgraduates in China, this study investigated the tight reciprocal relationship between psychological empowerment and positive mental well-being among postgraduates. To that end, a help enables a theoretical analysis of role clarity, academic emotion, and positive psychological health was developed, and its validity and reliability were demonstrated for the first time using the normalized postgrad relationship with supervisor scale, academic emotion scale, and positive mental scale, as well as questionnaire data from Chinese postgraduate students. This study used the cross-lagged (ARCL) panel model data to longitudinally measure 798 valid data from two survey questions polls taken in 2019 (T1) and 2021 (T2) to investigate the link between supervisor support and positive graduate student mental well-being in a bidirectional relationship of influence. The study discovered that mentor assistance could have a considerable beneficial impact on graduate students' academic emotions and, as a result, indirectly help learners attain positive mental health development. This verifies the theoretical premise that academic emotions partially mediate the effect of mentor support on positive mental health development and argues for the coexistence of the two. The outcomes of this study can help researchers gain a better knowledge of the dynamic interplay among three different research variables: supervisor support, academic emotions, and positive mental health, as well as fill gaps in previous research. In this regard, the study indicated that mentor assistance directly stimulates students' academic drive and assists graduate students in developing good academic emotions, which contributes to the development of positive mental health. However, given the restricted measurement time in this study's cross-lagged panel data and the potential effect of moderating effects other than academic mood on graduate students' good mental health, the results of this study need to be more fully understood and validated.Keywords: supervisor support, academic emotions, positive mental health, interaction effects, longitudinal cross-lagged measurements
Procedia PDF Downloads 879684 Thermal Network Model for a Large Scale AC Induction Motor
Authors: Sushil Kumar, M. Dakshina Murty
Abstract:
Thermal network modelling has proven to be important tool for thermal analysis of electrical machine. This article investigates numerical thermal network model and experimental performance of a large-scale AC motor. Experimental temperatures were measured using RTD in the stator which have been compared with the numerical data. Thermal network modelling fairly predicts the temperature of various components inside the large-scale AC motor. Results of stator winding temperature is compared with experimental results which are in close agreement with accuracy of 6-10%. This method of predicting hot spots within AC motors can be readily used by the motor designers for estimating the thermal hot spots of the machine.Keywords: AC motor, thermal network, heat transfer, modelling
Procedia PDF Downloads 3269683 Evaluation of Flange Effects on the Lateral In-Plane Response of Brick Masonry Walls
Authors: Hizb Ullah Sajid, Muhammad Ashraf, Naveed Ahmad Qaisar Ali, Sikandar Hayat Sajid
Abstract:
This research study investigates experimentally the effects of flanges (transverse walls) on the lateral in-plane response of brick masonry walls. The experimental work included lateral in-plane quasi-static cyclic tests on full-scale walls (both with & without flanges). The flanges were introduced at both ends of the in-plane wall. In particular the damage mechanism, lateral in-plane stiffness & strength, deformability and energy dissipation of the two classes of walls are compared and the differences are quantified to help understand the effects of flanges on the in-plane response of masonry walls. The available analytical models for the in-plane shear strength & deformation evaluation of masonry walls are critically analyzed. Recommendations are made for the lateral in-plane capacity assessment of brick masonry walls including the contribution of transverse walls.Keywords: brick masonry, damage mechanism, flanges effects, in-plane response
Procedia PDF Downloads 3829682 Virtual Assessment of Measurement Error in the Fractional Flow Reserve
Authors: Keltoum Chahour, Mickael Binois
Abstract:
Due to a lack of standardization during the invasive fractional flow reserve (FFR) procedure, the index is subject to many sources of uncertainties. In this paper, we investigate -through simulation- the effect of the (FFR) device position and configuration on the obtained value of the (FFR) fraction. For this purpose, we use computational fluid dynamics (CFD) in a 3D domain corresponding to a diseased arterial portion. The (FFR) pressure captor is introduced inside it with a given length and coefficient of bending to capture the (FFR) value. To get over the computational limitations, basically, the time of the simulation is about 2h 15min for one (FFR) value; we generate a Gaussian Process (GP) model for (FFR) prediction. The (GP) model indicates good accuracy and demonstrates the effective error in the measurement created by the random configuration of the pressure captor.Keywords: fractional flow reserve, Gaussian processes, computational fluid dynamics, drift
Procedia PDF Downloads 1349681 The Efficacy of Lithium vs. Valporate on Bipolar Patients and Their Sexual Side Effect: A Meta-Analysis of 4159 Patients
Authors: Yasmeen Jamal Alabdallat, Almutazballlah Bassam Qablan, Obada Ahmad Al Jayyousi, Ihdaa Mahmoud Bani Khalaf, Eman E. Alshial
Abstract:
Background: Bipolar disorder, formerly known as manic depression, is a mental health status that leads to extreme mood swings that include emotional lows (depression) and highs (mania or hypomania). This systematic review and meta-analysis aimed to assess the safety and efficacy of lithium versus valproate among bipolar patients. Methods: A computer literature search of PubMed, Scopus, Web of Science, and Cochrane Central Register of Controlled Trials was conducted from inception until June 2022. Studies comparing lithium versus valproate among bipolar patients were selected for the analysis, and all relevant outcomes were pooled in the meta-analysis using Review Manager Software. Results: 11 Randomized Clinical Trials were included in this meta-analysis with a total of 4159 patients. Our meta showed that lithium was superior to valproate in terms of Young Mania Rating Scale (YMRS) (MD = 0.00 with 95% CI, (-0.55 – 0.55; I2 = 0%), P = 1.00). The results of the Hamilton Depression Rating Scale (HDRS) showed that the overall effect favored the valproate treated group (MD = 1.41 with 95% CI, (-0.15 – 2.67; I2 = 0%), P = 0.03). Concerning the results of the Montgomery-Asberg Depression Rating Scale (MADRS), the results showed that the lithium was superior to valproate (MD = 0.03 with 95% CI, (-0.80 to 0.87; I2 = 40%), P = 0.94). In terms of the sexual side effect, we found that the valproate was superior to lithium (RR 1.19 with 95% CI, (0.74 to 1.91; I2 = 0%), P = 0.47). The lithium-treated group was superior in comparison to valproate treated group in terms of Abnormal Involuntary Movement Scale (AIMS) (MD = -0.03 with 95% CI (-0.38 to 0.32; I2 = 0%), P = 0.87). The lithium was more favorable in terms of Simpson-Agnes scale (MD = -0.40 with 95% CI, (-0.86 to 0.06; I2 = 0%), P = 0.09). The results of the Barnes akathisia scale showed that the overall effect of the valproate was more favorable in comparison to lithium (MD = 0.05 with 95% CI, (-0.12 to 0.22; I2 = 0%), P = 0.57). Conclusion: Our study revealed that on the scales of efficacy Lithium treated group surpassed Valproate treated group in terms of Young Mania Rating Scale (YMRS), Abnormal Involuntary Movement Scale (AIMS) and Simpson-Agnes scale, but valproate surpassed it in Barnes Akathisia scale. Furthermore, on the scales of depression Hamilton Depression Rating Scale (HDRS) showed that the overall effect favored Valproate treated group, but Lithium surpassed valproate in terms of Montgomery-Asberg Depression Rating Scale (MADRS). Valproate surpassed Lithium in terms of sexual side effects.Keywords: bipolar, mania, bipolar-depression, sexual dysfunction, sexual side effects, treatment
Procedia PDF Downloads 1559680 Online Measurement of Fuel Stack Elongation
Authors: Sung Ho Ahn, Jintae Hong, Chang Young Joung, Tae Ho Yang, Sung Ho Heo, Seo Yun Jang
Abstract:
The performances of nuclear fuels and materials are qualified at an irradiation system in research reactors operating under the commercial nuclear power plant conditions. Fuel centerline temperature, coolant temperature, neutron flux, deformations of fuel stack and swelling are important parameters needed to analyze the nuclear fuel performances. The dimensional stability of nuclear fuels is a key parameter measuring the fuel densification and swelling. In this study, the fuel stack elongation is measured using a LVDT. A mockup LVDT instrumented fuel rod is developed. The performances of mockup LVDT instrumented fuel rod is evaluated by experiments.Keywords: axial deformation, elongation measurement, in-pile instrumentation, LVDT
Procedia PDF Downloads 5349679 Evaluating Electronic Service Quality in Banking Iran
Authors: Vahid Bairami Rad
Abstract:
With the rapid growth of the Internet and the globalization of the market, most enterprises are trying to attract and win customers in the highly competitive electronic market. Better e-service quality will enhance the relationship with customers and their satisfaction. So the measurement of eservice quality is very important but it is a complex process due to the complex nature of services. Literature predicts that there is a lack of universal definition of e-service quality. The e-service quality measures in banking have great importance in achieving high customer base. This paper proposes a conceptual model for measuring e-service quality in Iranian Banking Iran. Nine dimensions reliability, ease of use, personalization, security and trust, website aesthetic, responsiveness, contact and speed of delivery had been identified. The results of this paper may help to develop a proper scale to measure the e-service quality in Iranian Banking Industry, which may assist to maintain and improve the performance and effectiveness of e-service quality to retain customers.Keywords: electronic banking, Dimensions, customer service quality, electronic, communication
Procedia PDF Downloads 5009678 Neural Synchronization - The Brain’s Transfer of Sensory Data
Authors: David Edgar
Abstract:
To understand how the brain’s subconscious and conscious functions, we must conquer the physics of Unity, which leads to duality’s algorithm. Where the subconscious (bottom-up) and conscious (top-down) processes function together to produce and consume intelligence, we use terms like ‘time is relative,’ but we really do understand the meaning. In the brain, there are different processes and, therefore, different observers. These different processes experience time at different rates. A sensory system such as the eyes cycles measurement around 33 milliseconds, the conscious process of the frontal lobe cycles at 300 milliseconds, and the subconscious process of the thalamus cycle at 5 milliseconds. Three different observers experience time differently. To bridge observers, the thalamus, which is the fastest of the processes, maintains a synchronous state and entangles the different components of the brain’s physical process. The entanglements form a synchronous cohesion between the brain components allowing them to share the same state and execute in the same measurement cycle. The thalamus uses the shared state to control the firing sequence of the brain’s linear subconscious process. Sharing state also allows the brain to cheat on the amount of sensory data that must be exchanged between components. Only unpredictable motion is transferred through the synchronous state because predictable motion already exists in the shared framework. The brain’s synchronous subconscious process is entirely based on energy conservation, where prediction regulates energy usage. So, the eyes every 33 milliseconds dump their sensory data into the thalamus every day. The thalamus is going to perform a motion measurement to identify the unpredictable motion in the sensory data. Here is the trick. The thalamus conducts its measurement based on the original observation time of the sensory system (33 ms), not its own process time (5 ms). This creates a data payload of synchronous motion that preserves the original sensory observation. Basically, a frozen moment in time (Flat 4D). The single moment in time can then be processed through the single state maintained by the synchronous process. Other processes, such as consciousness (300 ms), can interface with the synchronous state to generate awareness of that moment. Now, synchronous data traveling through a separate faster synchronous process creates a theoretical time tunnel where observation time is tunneled through the synchronous process and is reproduced on the other side in the original time-relativity. The synchronous process eliminates time dilation by simply removing itself from the equation so that its own process time does not alter the experience. To the original observer, the measurement appears to be instantaneous, but in the thalamus, a linear subconscious process generating sensory perception and thought production is being executed. It is all just occurring in the time available because other observation times are slower than thalamic measurement time. For life to exist in the physical universe requires a linear measurement process, it just hides by operating at a faster time relativity. What’s interesting is time dilation is not the problem; it’s the solution. Einstein said there was no universal time.Keywords: neural synchronization, natural intelligence, 99.95% IoT data transmission savings, artificial subconscious intelligence (ASI)
Procedia PDF Downloads 1269677 Longitudinal Vibration of a Micro-Beam in a Micro-Scale Fluid Media
Authors: M. Ghanbari, S. Hossainpour, G. Rezazadeh
Abstract:
In this paper, longitudinal vibration of a micro-beam in micro-scale fluid media has been investigated. The proposed mathematical model for this study is made up of a micro-beam and a micro-plate at its free end. An AC voltage is applied to the pair of piezoelectric layers on the upper and lower surfaces of the micro-beam in order to actuate it longitudinally. The whole structure is bounded between two fixed plates on its upper and lower surfaces. The micro-gap between the structure and the fixed plates is filled with fluid. Fluids behave differently in micro-scale than macro, so the fluid field in the gap has been modeled based on micro-polar theory. The coupled governing equations of motion of the micro-beam and the micro-scale fluid field have been derived. Due to having non-homogenous boundary conditions, derived equations have been transformed to an enhanced form with homogenous boundary conditions. Using Galerkin-based reduced order model, the enhanced equations have been discretized over the beam and fluid domains and solve simultaneously in order to obtain force response of the micro-beam. Effects of micro-polar parameters of the fluid as characteristic length scale, coupling parameter and surface parameter on the response of the micro-beam have been studied.Keywords: micro-polar theory, Galerkin method, MEMS, micro-fluid
Procedia PDF Downloads 1849676 Measurement of Temperature, Humidity and Strain Variation Using Bragg Sensor
Authors: Amira Zrelli, Tahar Ezzeddine
Abstract:
Measurement and monitoring of temperature, humidity and strain variation are very requested in great fields and areas such as structural health monitoring (SHM) systems. Currently, the use of fiber Bragg grating sensors (FBGS) is very recommended in SHM systems due to the specifications of these sensors. In this paper, we present the theory of Bragg sensor, therefore we try to measure the efficient variation of strain, temperature and humidity (SV, ST, SH) using Bragg sensor. Thus, we can deduce the fundamental relation between these parameters and the wavelength of Bragg sensor.Keywords: Fiber Bragg Grating Sensors (FBGS), strain, temperature, humidity, structural health monitoring (SHM)
Procedia PDF Downloads 3169675 Studies on Lucrative Process Layout for Medium Scale Industries
Authors: Balamurugan Baladhandapani, Ganesh Renganathan, V. R. Sanal Kumar
Abstract:
In this paper a comprehensive review on various factory layouts has been carried out for designing a lucrative process layout for medium scale industries. Industry data base reveals that the end product rejection rate is on the order of 10% amounting large profit loss. In order to avoid these rejection rates and to increase the quality product production an intermediate non-destructive testing facility (INDTF) has been recommended for increasing the overall profit. We observed through detailed case studies that while introducing INDTF to medium scale industries the expensive production process can be avoided to the defective products well before its final shape. Additionally, the defective products identified during the intermediate stage can be effectively utilized for other applications or recycling; thereby the overall wastage of the raw materials can be reduced and profit can be increased. We concluded that the prudent design of a factory layout through critical path method facilitating with INDTF will warrant profitable outcome.Keywords: intermediate non-destructive testing, medium scale industries, process layout design
Procedia PDF Downloads 5029674 Finite Element Modeling of Stockbridge Damper and Vibration Analysis: Equivalent Cable Stiffness
Authors: Nitish Kumar Vaja, Oumar Barry, Brian DeJong
Abstract:
Aeolian vibrations are the major cause for the failure of conductor cables. Using a Stockbridge damper reduces these vibrations and increases the life span of the conductor cable. Designing an efficient Stockbridge damper that suits the conductor cable requires a robust mathematical model with minimum assumptions. However it is not easy to analytically model the complex geometry of the messenger. Therefore an equivalent stiffness must be determined so that it can be used in the analytical model. This paper examines the bending stiffness of the cable and discusses the effect of this stiffness on the natural frequencies. The obtained equivalent stiffness compensates for the assumption of modeling the messenger as a rod. The results from the free vibration analysis of the analytical model with the equivalent stiffness is validated using the full scale finite element model of the Stockbridge damper.Keywords: equivalent stiffness, finite element model, free vibration response, Stockbridge damper
Procedia PDF Downloads 2869673 Employability Potential of Differently Abled in the Indian Apparel Industry
Authors: Gunjita Shami, Noopur Anand
Abstract:
The pilot run of 50 days was undertaken to test employability potential of people with visual and hearing & speech impairment. Various roles in an apparel manufacturing set up like spreading of fabric for cutting, folding, sealing and labeling cartons, pasting size barcode stickers on packed garments, removing tickets from the garments in the finishing stage were studied. Their performance was quantified basis timesheets for all the days and improvement per day was quantified. Their final day output was compared to that of the able-bodied worker. For example in the carton making activity on day one visually impaired worker was making one box every three minutes which improved to four boxes per minute on day 28 displaying 91.6% improvement compared or an improvement of 3.6% per day which was comparable to the able-bodied seasoned workers, who were making 5 boxes per minute. The performance of persons with hearing and speech impairment in the finishing department was 10% higher than that of able-bodied seasoned workers in the same process. Overall in all the activities the differently abled showed day to day improvement of 65% while able bodied displayed improvement of 52%. On the first day performance of able-bodied worker was 75% better than that of differently abled while on the 50th day it was only 20% better. Therefore the performance of persons with disabilities was found comparable to the able bodied person. The results, though on a small scale, showed a big promise of employment of persons with disability in the apparel industry. Armed with the promising result a full-scale study has been undertaken to identify the roles suitable for certain kind of disability in apparel production, work-aids required to assist the differently abled to improve performance and measures to be undertaken to make production floor 'friendlier' for them. The results have been discussed in this paper which opens doors for integrating differently abled into the world projected and assumed for only able-bodied.Keywords: apparel sector, differently abled, employability, performance, work-aid
Procedia PDF Downloads 1499672 Effect of Self-Compassion Techniques for Individuals with Depression: A Pilot Study
Authors: Piyanud Chompookard
Abstract:
This research aims to study the effect of self-compassion techniques for individuals with depression (A pilot study). A quasi-experimental research with pretest-posttest is used to design this work. The research includes 30 participants, divided into the experimental group (ten samples) and the control group (twenty samples). The experimental group received a self-compassion techniques with an appropriate treatment for a total six times. The control group received an appropriate treatment. The measurement of this study using the Hamilton Rating Scale for Depression (Thai version). There are significant differences in levels of depression after received a self-compassion techniques with an appropriate treatment (p<.01). And there are significant differences in levels of depression between the experimental group and the control group (p<.01).Keywords: depression, self compassion techniques, psychotherapy, pilot study
Procedia PDF Downloads 1419671 Experimental and Finite Element Forming Limit Diagrams for Interstitial Free Steels
Authors: Basavaraj Vadavadagi, Satishkumar Shekhawat
Abstract:
Interstitial free steels posses better formability and have many applications in automotive industries. Forming limit diagrams (FLDs) indicate the formability of materials which can be determined by experimental and finite element (FE) simulations. FLDs were determined experimentally by LDH test, utilizing optical strain measurement system for measuring the strains in different width specimens and by FE simulations in Interstitial Free (IF) and Interstitial Free High Strength (IFHS) steels. In this study, the experimental and FE simulated FLDs are compared and also the stress based FLDs were investigated.Keywords: forming limit diagram, limiting dome height, optical strain measurement, interstitial
Procedia PDF Downloads 2329670 Memristive Properties of Nanostructured Porous Silicon
Authors: Madina Alimova, Margulan Ibraimov, Ayan Tileu
Abstract:
The paper describes methods for obtaining porous structures with the properties of a silicon-based memristor and explains the electrical properties of porous silicon films. Based on the results, there is a positive shift in the current-voltage characteristics (CVC) after each measurement, i.e., electrical properties depend not only on the applied voltage but also on the previous state. After 3 minutes of rest, the film returns to its original state (reset). The method for obtaining a porous silicon nanofilm with the properties of a memristor is simple and does not require additional effort. Based on the measurement results, the typical memristive behavior of the porous silicon nanofilm is analyzed.Keywords: porous silicon, current-voltage characteristics, memristor, nanofilms
Procedia PDF Downloads 1309669 Reliability and Validity for Measurement of Body Composition: A Field Method
Authors: Ahmad Hashim, Zarizi Ab Rahman
Abstract:
Measurement of body composition via a field method has the most popular instruments which are used to estimate the percentage of body fat. Among the instruments used are the Body Mass Index, Bio Impedance Analysis and Skinfold Test. All three of these instruments do not involve high costs, do not require high technical skills, are mobile, save time, and are suitable for use in large populations. Because all three instruments can estimate the percentage of body fat, but it is important to identify the most appropriate instruments and have high reliability. Hence, this study was conducted to determine the reliability and convergent validity of the instruments. A total of 40 students, males and females aged between 13 and 14 years participated in this study. The study found that the test retest and Pearson correlation coefficient of reliability for the three instruments is very high, r = .99. While the inter class reliability also are at high level with r = .99 for Body Mass Index and Bio Impedance Analysis, r = .96 for Skin fold test. Intra class reliability coefficient for these three instruments is too high for Body Mass Index r = .99, Bio Impedance Analysis r = .97, and Skin fold Test r = .90. However, Standard Error of Measurement value for all three instruments indicates the Body Mass Index is the most appropriate instrument with a mean value of .000672 compared with other instruments. The findings show that the Body Mass Index is an instrument which is the most accurate and reliable in estimating body fat percentage for the population studied.Keywords: reliability, validity, body mass index, bio impedance analysis and skinfold test
Procedia PDF Downloads 3369668 Regularity and Maximal Congruence in Transformation Semigroups with Fixed Sets
Authors: Chollawat Pookpienlert, Jintana Sanwong
Abstract:
An element a of a semigroup S is called left (right) regular if there exists x in S such that a=xa² (a=a²x) and said to be intra-regular if there exist u,v in such that a=ua²v. Let T(X) be the semigroup of all full transformations on a set X under the composition of maps. For a fixed nonempty subset Y of X, let Fix(X,Y)={α ™ T(X) : yα=y for all y ™ Y}, where yα is the image of y under α. Then Fix(X,Y) is a semigroup of full transformations on X which fix all elements in Y. Here, we characterize left regular, right regular and intra-regular elements of Fix(X,Y) which characterizations are shown as follows: For α ™ Fix(X,Y), (i) α is left regular if and only if Xα\Y = Xα²\Y, (ii) α is right regular if and only if πα = πα², (iii) α is intra-regular if and only if | Xα\Y | = | Xα²\Y | such that Xα = {xα : x ™ X} and πα = {xα⁻¹ : x ™ Xα} in which xα⁻¹ = {a ™ X : aα=x}. Moreover, those regularities are equivalent if Xα\Y is a finite set. In addition, we count the number of those elements of Fix(X,Y) when X is a finite set. Finally, we determine the maximal congruence ρ on Fix(X,Y) when X is finite and Y is a nonempty proper subset of X. If we let | X \Y | = n, then we obtain that ρ = (Fixn x Fixn) ∪ (H ε x H ε) where Fixn = {α ™ Fix(X,Y) : | Xα\Y | < n} and H ε is the group of units of Fix(X,Y). Furthermore, we show that the maximal congruence is unique.Keywords: intra-regular, left regular, maximal congruence, right regular, transformation semigroup
Procedia PDF Downloads 2299667 Preoperative Anxiety Evaluation: Comparing the Visual Facial Anxiety Scale/Yumul Faces Anxiety Scale, Numerical Verbal Rating Scale, Categorization Scale, and the State-Trait Anxiety Inventory
Authors: Roya Yumul, Chse, Ofelia Loani Elvir Lazo, David Chernobylsky, Omar Durra
Abstract:
Background: Preoperative anxiety has been shown to be caused by the fear associated with surgical and anesthetic complications; however, the current gold standard for assessing patient anxiety, the STAI, is problematic to use in the preoperative setting given the duration and concentration required to complete the 40-item extensive questionnaire. Our primary aim in the study is to investigate the correlation of the Visual Facial Anxiety Scale (VFAS) and Numerical Verbal Rating Scale (NVRS) to State-Trait Anxiety Inventory (STAI) to determine the optimal anxiety scale to use in the perioperative setting. Methods: A clinical study of patients undergoing various surgeries was conducted utilizing each of the preoperative anxiety scales. Inclusion criteria included patients undergoing elective surgeries, while exclusion criteria included patients with anesthesia contraindications, inability to comprehend instructions, impaired judgement, substance abuse history, and those pregnant or lactating. 293 patients were analyzed in terms of demographics, anxiety scale survey results, and anesthesia data via Spearman Coefficients, Chi-Squared Analysis, and Fischer’s exact test utilized for comparison analysis. Results: Statistical analysis showed that VFAS had a higher correlation to STAI than NVRS (rs=0.66, p<0.0001 vs. rs=0.64, p<0.0001). The combined VFAS-Categorization Scores showed the highest correlation with the gold standard (rs=0.72, p<0.0001). Subgroup analysis showed similar results. STAI evaluation time (247.7 ± 54.81 sec) far exceeds VFAS (7.29 ± 1.61 sec), NVRS (7.23 ± 1.60 sec), and Categorization scales (7.29 ± 1.99 sec). Patients preferred VFAS (54.4%), Categorization (11.6%), and NVRS (8.8%). Anesthesiologists preferred VFAS (63.9%), NVRS (22.1%), and Categorization Scales (14.0%). Of note, the top five causes of preoperative anxiety were determined to be waiting (56.5%), pain (42.5%), family concerns (40.5%), no information about surgery (40.1%), or anesthesia (31.6%). Conclusions: Combined VFAS-Categorization Score (VCS) demonstrates the highest correlation to the gold standard, STAI. Both VFAS and Categorization tests also take significantly less time than STAI, which is critical in the preoperative setting. Among both patients and anesthesiologists, VFAS was the most preferred scale. This forms the basis of the Yumul FACES Anxiety Scale, designed for quick quantization and assessment in the preoperative setting while maintaining a high correlation to the golden standard. Additional studies using the formulated Yumul FACES Anxiety Scale are merited.Keywords: numerical verbal anxiety scale, preoperative anxiety, state-trait anxiety inventory, visual facial anxiety scale
Procedia PDF Downloads 1409666 FE Analysis of Blade-Disc Dovetail Joints Using Mortar Base Frictional Contact Formulation
Authors: Abbas Moradi, Mohsen Safajoy, Reza Yazdanparast
Abstract:
Analysis of blade-disc dovetail joints is one of the biggest challenges facing designers of aero-engines. To avoid comparatively expensive experimental full-scale tests, numerical methods can be used to simulate loaded disc-blades assembly. Mortar method provides a powerful and flexible tool for solving frictional contact problems. In this study, 2D frictional contact in dovetail has been analysed based on the mortar algorithm. In order to model the friction, the classical law of coulomb and moving friction cone algorithm is applied. The solution is then obtained by solving the resulting set of non-linear equations using an efficient numerical algorithm based on Newton–Raphson Method. The numerical results show that this approach has better convergence rate and accuracy than other proposed numerical methods.Keywords: computational contact mechanics, dovetail joints, nonlinear FEM, mortar approach
Procedia PDF Downloads 3529665 Image Multi-Feature Analysis by Principal Component Analysis for Visual Surface Roughness Measurement
Authors: Wei Zhang, Yan He, Yan Wang, Yufeng Li, Chuanpeng Hao
Abstract:
Surface roughness is an important index for evaluating surface quality, needs to be accurately measured to ensure the performance of the workpiece. The roughness measurement based on machine vision involves various image features, some of which are redundant. These redundant features affect the accuracy and speed of the visual approach. Previous research used correlation analysis methods to select the appropriate features. However, this feature analysis is independent and cannot fully utilize the information of data. Besides, blindly reducing features lose a lot of useful information, resulting in unreliable results. Therefore, the focus of this paper is on providing a redundant feature removal approach for visual roughness measurement. In this paper, the statistical methods and gray-level co-occurrence matrix(GLCM) are employed to extract the texture features of machined images effectively. Then, the principal component analysis(PCA) is used to fuse all extracted features into a new one, which reduces the feature dimension and maintains the integrity of the original information. Finally, the relationship between new features and roughness is established by the support vector machine(SVM). The experimental results show that the approach can effectively solve multi-feature information redundancy of machined surface images and provides a new idea for the visual evaluation of surface roughness.Keywords: feature analysis, machine vision, PCA, surface roughness, SVM
Procedia PDF Downloads 2129664 Block N Lvi from the Northern Side of Parthenon Frieze: A Case Study of Augmented Reality for Museum Application
Authors: Donato Maniello, Alessandra Cirafici, Valeria Amoretti
Abstract:
This paper aims to present a new method that consists in the use of video mapping techniques – that is a particular form of augmented reality, which could produce new tools - different from the ones that are actually in use - for an interactive Museum experience. With the words 'augmented reality', we mean the addition of more information than what the visitor would normally perceive; this information is mediated by the use of computer and projector. The proposed application involves the creation of a documentary that depicts and explains the history of the artifact and illustrates its features; this must be projected on the surface of the faithful copy of the freeze (obtained in full-scale with a 3D printer). This mode of operation uses different techniques that allow passing from the creation of the model to the creation of contents through an accurate historical and artistic analysis, and finally to the warping phase, that will permit to overlap real and virtual models. The ultimate step, that is still being studied, includes the creation of interactive contents that would be activated by visitors through appropriate motion sensors.Keywords: augmented reality, multimedia, parthenon frieze, video mapping
Procedia PDF Downloads 3879663 Biosignal Measurement System Based on Ultra-Wide Band Human Body Communication
Authors: Jonghoon Kim, Gilwon Yoon
Abstract:
A wrist-band type biosignal measurement system and its data transfer through human body communication (HBC) were investigated. An HBC method based on pulses of ultra-wide band instead of using frequency or amplitude modulations was studied and implemented since the system became very compact and it was more suited for personal or mobile health monitoring. Our system measured photo-plethysmogram (PPG) and measured PPG signals were transmitted through a finger to a monitoring PC system. The device was compact and low-power consuming. HBC communication has very strong security measures since it does not use wireless network. Furthermore, biosignal monitoring system becomes handy because it does not need to have wire connections.Keywords: biosignal, human body communication, mobile health, PPG, ultrawide band
Procedia PDF Downloads 4769662 Development of a Force-Sensing Toothbrush for Gum Recession Measurement Using Programmable Automation Controller
Authors: Sorayya Kazemi, Hamed Kharrati, Mehdi Abedinpour Fallah
Abstract:
This paper presents the design and implementation of a novel electric pressure-sensitive toothbrush, capable of measuring the forces applied to the head of the brush. The developed device is used for gum recession measurement. In particular, the percentage of gum recession is measured by a Programmable Automation controller (PAC). Moreover, the brushing forces are measured by a Force Sensing Resistor (FSR) sensor. These forces are analog inputs of PAC. According to the applied forces during patient’s brushing and the patient’s percentage of gum recession, dentist sets the standard force range. The instrument alarms when the patient applies a force over the set range.Keywords: gum recession, force sensing resistor, controller, toothbrush
Procedia PDF Downloads 4979661 Development of a Performance Measurement Model for Hospitals Using Multi-Criteria Decision Making (MCDM) Techniques: A Case Study of Three South Australian Major Public Hospitals
Authors: Mohammad Safaeipour, Yousef Amer
Abstract:
This study directs its focus on developing a conceptual model to offer a systematic and integrated method to weigh the related measures and evaluate a competence of hospitals and rank of the selected hospitals that involve and consider the stakeholders’ key performance indicators (KPI’s). The Analytical Hierarchy Process (AHP) approach will use to weigh the dimensions and related sub- components. The weights and performance scores will combine by using the Technique for Order Performance by Similarity to Ideal Solution (TOPSIS) and rank the selected hospitals. The results of this study provide interesting insight into the necessity of process improvement implementation in which hospital that received the lowest ranking score.Keywords: performance measurement system, PMS, hospitals, AHP, TOPSIS
Procedia PDF Downloads 3739660 Design and Test a Robust Bearing-Only Target Motion Analysis Algorithm Based on Modified Gain Extended Kalman Filter
Authors: Mohammad Tarek Al Muallim, Ozhan Duzenli, Ceyhun Ilguy
Abstract:
Passive sonar is a method for detecting acoustic signals in the ocean. It detects the acoustic signals emanating from external sources. With passive sonar, we can determine the bearing of the target only, no information about the range of the target. Target Motion Analysis (TMA) is a process to estimate the position and speed of a target using passive sonar information. Since bearing is the only available information, the TMA technique called Bearing-only TMA. Many TMA techniques have been developed. However, until now, there is not a very effective method that could be used to always track an unknown target and extract its moving trace. In this work, a design of effective Bearing-only TMA Algorithm is done. The measured bearing angles are very noisy. Moreover, for multi-beam sonar, the measurements is quantized due to the sonar beam width. To deal with this, modified gain extended Kalman filter algorithm is used. The algorithm is fine-tuned, and many modules are added to improve the performance. A special validation gate module is used to insure stability of the algorithm. Many indicators of the performance and confidence level measurement are designed and tested. A new method to detect if the target is maneuvering is proposed. Moreover, a reactive optimal observer maneuver based on bearing measurements is proposed, which insure converging to the right solution all of the times. To test the performance of the proposed TMA algorithm a simulation is done with a MATLAB program. The simulator program tries to model a discrete scenario for an observer and a target. The simulator takes into consideration all the practical aspects of the problem such as a smooth transition in the speed, a circular turn of the ship, noisy measurements, and a quantized bearing measurement come for multi-beam sonar. The tests are done for a lot of given test scenarios. For all the tests, full tracking is achieved within 10 minutes with very little error. The range estimation error was less than 5%, speed error less than 5% and heading error less than 2 degree. For the online performance estimator, it is mostly aligned with the real performance. The range estimation confidence level gives a value equal to 90% when the range error less than 10%. The experiments show that the proposed TMA algorithm is very robust and has low estimation error. However, the converging time of the algorithm is needed to be improved.Keywords: target motion analysis, Kalman filter, passive sonar, bearing-only tracking
Procedia PDF Downloads 4029659 Lessons Learned in Developing a Clinical Information System and Electronic Health Record (EHR) System That Meet the End User Needs and State of Qatar's Emerging Regulations
Authors: Darshani Premaratne, Afshin Kandampath Puthiyadath
Abstract:
The Government of Qatar is taking active steps in improving quality of health care industry in the state of Qatar. In this initiative development and market introduction of Clinical Information System and Electronic Health Record (EHR) system are proved to be a highly challenging process. Along with an organization specialized on EHR system development and with the blessing of Health Ministry of Qatar the process of introduction of EHR system in Qatar healthcare industry was undertaken. Initially a market survey was carried out to understand the requirements. Secondly, the available government regulations, needs and possible upcoming regulations were carefully studied before deployment of resources for software development. Sufficient flexibility was allowed to cater for both the changes in the market and the regulations. As the first initiative a system that enables integration of referral network where referral clinic and laboratory system for all single doctor (and small scale) clinics was developed. Setting of isolated single doctor clinics all over the state to bring in to an integrated referral network along with a referral hospital need a coherent steering force and a solid top down framework. This paper discusses about the lessons learned in developing, in obtaining approval of the health ministry and in introduction to the industry of the single doctor referral network along with an EHR system. It was concluded that development of this nature required continues balance between the market requirements and upcoming regulations. Further accelerating the development based on the emerging needs, implementation based on the end user needs while tallying with the regulations, diffusion, and uptake of demand-driven and evidence-based products, tools, strategies, and proper utilization of findings were equally found paramount in successful development of end product. Development of full scale Clinical Information System and EHR system are underway based on the lessons learned. The Government of Qatar is taking active steps in improving quality of health care industry in the state of Qatar. In this initiative development and market introduction of Clinical Information System and Electronic Health Record (EHR) system are proved to be a highly challenging process. Along with an organization specialized on EHR system development and with the blessing of Health Ministry of Qatar the process of introduction of EHR system in Qatar healthcare industry was undertaken. Initially a market survey was carried out to understand the requirements. Secondly the available government regulations, needs and possible upcoming regulations were carefully studied before deployment of resources for software development. Sufficient flexibility was allowed to cater for both the changes in the market and the regulations. As the first initiative a system that enables integration of referral network where referral clinic and laboratory system for all single doctor (and small scale) clinics was developed. Setting of isolated single doctor clinics all over the state to bring in to an integrated referral network along with a referral hospital need a coherent steering force and a solid top down framework. This paper discusses about the lessons learned in developing, in obtaining approval of the health ministry and in introduction to the industry of the single doctor referral network along with an EHR system. It was concluded that development of this nature required continues balance between the market requirements and upcoming regulations. Further accelerating the development based on the emerging needs, implementation based on the end user needs while tallying with the regulations, diffusion, and uptake of demand-driven and evidence-based products, tools, strategies, and proper utilization of findings were equally found paramount in successful development of end product. Development of full scale Clinical Information System and EHR system are underway based on the lessons learned.Keywords: clinical information system, electronic health record, state regulations, integrated referral network of clinics
Procedia PDF Downloads 3629658 Assessment of Solid Insulating Material Using Partial Discharge Characteristics
Authors: Qasim Khan, Furkan Ahmad, Asfar A. Khan, M. Saad Alam, Faiz Ahmad
Abstract:
In this paper, partial discharge analysis is performed in cavities artificially created in insulation. The setup is according with Cigre-II Method. Circular Samples created from Perspex Sheet with different configuration with changing number of cavities. Assessment of insulation health can be performed by Partial Discharge measurement as this has been found to be important means of condition monitoring. The experiments are done using MPD 540, which is a modern partial discharge measurement system. By analyzing the PD activity obtained for various voids/cavities, it is observed that the PD voltages show variation for cavity’s diameter, depth even for its ratios. This can be employed for scrutiny of insulation system.Keywords: partial discharges, condition monitoring, insulation defects, degradation and corrosion, PMMA
Procedia PDF Downloads 5179657 Wheel Diameter and Width Influence in Variability of Brake Data Measurement at Ministry of Transport Facilities
Authors: Carolina Senabre, Sergio Valero, Emilio Velasco
Abstract:
The brake systems of vehicles are tested periodically by a “brake tester” at Ministry of Transport (MOT) stations. This tester measures the effectiveness of vehicle. This parameter is established by the International Committee of Vehicle Inspection (CITA). In this paper, we present an investigation of the influence of the tire size on the measurements of brake force on three MOT brake testers. We performed an analysis of the vehicle braking capacity test at MOT stations. The influence of varying wheel diameter and width on the measurement of braking at MOT stations has been analyzed. Thereby, the MOT brake tester as a verification system for a vehicle has been evaluated.Keywords: brake tester, ministry of transport facilities, wheel diameter, efficiency
Procedia PDF Downloads 3769656 A Stochastic Analytic Hierarchy Process Based Weighting Model for Sustainability Measurement in an Organization
Authors: Faramarz Khosravi, Gokhan Izbirak
Abstract:
A weighted statistical stochastic based Analytical Hierarchy Process (AHP) model for modeling the potential barriers and enablers of sustainability for measuring and assessing the sustainability level is proposed. For context-dependent potential barriers and enablers, the proposed model takes the basis of the properties of the variables describing the sustainability functions and was developed into a realistic analytical model for the sustainable behavior of an organization. This thus serves as a means for measuring the sustainability of the organization. The main focus of this paper was the application of the AHP tool in a statistically-based model for measuring sustainability. Hence a strong weighted stochastic AHP based procedure was achieved. A case study scenario of a widely reported major Canadian electric utility was adopted to demonstrate the applicability of the developed model and comparatively examined its results with those of an equal-weighted model method. Variations in the sustainability of a company, as fluctuations, were figured out during the time. In the results obtained, sustainability index for successive years changed form 73.12%, 79.02%, 74.31%, 76.65%, 80.49%, 79.81%, 79.83% to more exact values 73.32%, 77.72%, 76.76%, 79.41%, 81.93%, 79.72%, and 80,45% according to priorities of factors that have found by expert views, respectively. By obtaining relatively necessary informative measurement indicators, the model can practically and effectively evaluate the sustainability extent of any organization and also to determine fluctuations in the organization over time.Keywords: AHP, sustainability fluctuation, environmental indicators, performance measurement
Procedia PDF Downloads 121