Search results for: wrist biomechanics
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 187

Search results for: wrist biomechanics

157 Viscoelastic Response of the Human Corneal Stroma Induced by Riboflavin/UVA Cross-Linking

Authors: C. Labate, M. P. De Santo, G. Lombardo, R. Barberi, M. Lombardo, N. M. Ziebarth

Abstract:

In the past decades, the importance of corneal biomechanics in the normal and pathological functions of the eye has gained its credibility. In fact, the mechanical properties of biological tissues are essential to their physiological function. We are convinced that an improved understanding of the nanomechanics of corneal tissue is important to understand the basic molecular interactions between collagen fibrils. Ultimately, this information will help in the development of new techniques to cure ocular diseases and in the development of biomimetic materials. Therefore, nanotechnology techniques are powerful tools and, in particular, Atomic Force Microscopy has demonstrated its ability to reliably characterize the biomechanics of biological tissues either at the micro- or nano-level. In the last years, we have investigated the mechanical anisotropy of the human corneal stroma at both the tissue and molecular levels. In particular, we have focused on corneal cross-linking, an established procedure aimed at slowing down or halting the progression of the disease known as keratoconus. We have obtained the first evidence that riboflavin/UV-A corneal cross-linking induces both an increase of the elastic response and a decrease of the viscous response of the most anterior stroma at the scale of stromal molecular interactions.

Keywords: atomic force spectroscopy, corneal stroma, cross-linking, viscoelasticity

Procedia PDF Downloads 308
156 Cystic Ganglionosis in Child: Rare Entity

Authors: Jatinder Pal Singh, Harpreet Singh, Gagandeep Singh Digra, Mandeep Kaur Sidhu, Pawan Kumar

Abstract:

Introduction: Ganglion cyst is a benign condition in which there is a cystic lesion in relation to a joint or a tendon sheath arising from myxoid degeneration of fibrous connective tissue. These can be unilocular or multilocular. In rare cases, there may be multiple ganglion cysts, known as cystic ganglionosis. They can occur at any age but are commonly seen in adults. Clinically they may be asymptomatic or present as swelling or mass effect in adjacent structures. These are common in extremities such as hands and feet. Case Presentation: 11-year-old female child presented with slowly progressive painless swelling of her right hand since the age of 4. Antenatal and perinatal history was unremarkable. Her family history was negative. She denies fever, malaise, morning stiffness, weight loss, fatigue, restriction of joint movements, or any sensory and motor deficit. Lab parameters were negative for inflammatory or infectious etiology. No other joint or extremity involvement was present. On physical examination, the swelling was present on the dorsum and palmer aspect of the right hand and wrist. They were non-tender on palpation without any motor or sensory deficit. MRI hand revealed multiple well-defined fluid signal intensity cystic appearing lesions in periarticular/intraarticular locations in relation to distal radio-ulnar, radio-carpal, intercarpal, carpometacarpal, metacarpophalangeal and interphalangeal joints as well as peritendinous location around flexor tendons more so in the region of wrist, palm, 1st and 5th digit and along extensor tendons in the region of wrist, largest one noted along flexor pollicis longus tendon in thenar region and along 1st digit measuring approx. 4.6 x 1.2 x 1.2 centimeter. Pressure erosions and bone remodelling were noted in the bases of the 2nd to 5th metacarpals, capitate, trapezoid, the distal shaft of 1st metacarpal, and proximal phalanx of 1st digit. Marrow edema was noted in the base and proximal shaft of the 4th metacarpal and proximal shaft of the 3rd metacarpal – likely stress or pressure related. The patient was advised of aspiration, but the family refused the procedure. Therefore the patient was kept on conservative treatment. Conclusion: Cystic ganglionosis is a rare condition with very few cases reported in the medical literature. Its prevalence and association are not known because of the rarity of this condition. It should be considered as an important differential in patients presenting with soft tissue swelling in extremities. Treatment option includes conservative management, aspiration, and surgery. Aspiration has a high recurrence rate. Although surgery has a low recurrence rate, it carries a high rate of complications. Imaging with MRI is essential for confirmation of the cystic nature of lesions and their relation with the joint capsules or tendons. This helps in differentiating from other soft tissue lesions and presurgical planning.

Keywords: radiology, rare, cystic ganglionosis, child

Procedia PDF Downloads 72
155 Efficacy of Botulinum Toxin in Alleviating Pain Syndrome in Stroke Patients with Upper Limb Spasticity

Authors: Akulov M. A., Zaharov V. O., Jurishhev P. E., Tomskij A. A.

Abstract:

Introduction: Spasticity is a severe consequence of stroke, leading to profound disability, decreased quality of life and decrease of rehabilitation efficacy [4]. Spasticity is often associated with pain syndrome, arising from joint damage of paretic limbs (postural arthropathy) or painful spasm of paretic limb muscles. It is generally accepted that injection of botulinum toxin into a cramped muscle leads to decrease of muscle tone and improves motion range in paretic limb, which is accompanied by pain alleviation. Study aim: To evaluate the change in pain syndrome intensity after incections of botulinum toxin A (Xeomin) in stroke patients with upper limb spasticity. Patients and methods. 21 patients aged 47-74 years were evaluated. Inclusion criteria were: acute stroke 4-7 months before the inclusion into the study, leading to spasticity of wrist and/or finger flexors, elbow flexor or forearm pronator, associated with severe pain syndrome. Patients received Xeomin as monotherapy 90-300 U, according to spasticity pattern. Efficacy evaluation was performed using Ashworth scale, disability assessment scale (DAS), caregiver burden scale and global treatment benefit assessment on weeks 2, 4, 8 and 12. Efficacy criterion was the decrease of pain syndrome by week 4 on PQLS and VAS. Results: The study revealed a significant improvement of measured indices after 4 weeks of treatment, which persisted until the 12 week of treatment. Xeomin is effective in reducing muscle tone of flexors of wrist, fingers and elbow, forearm pronators. By the 4th week of treatment we observed a significant improvement on DAS (р < 0,05), Ashworth scale (1-2 points) in all patients (р < 0,05), caregiver burden scale (р < 0,05). A significant decrease of pain syndrome by the 4th week of treatment on PQLS (р < 0,05) и VAS (р < 0,05) was observed. No adverse effect were registered. Conclusion: Xeomin is an effective treatment of pain syndrome in postural upper limb spasticity after stroke. Xeomin treatment leads to a significant improvement on PQLS and VAS.

Keywords: botulinum toxin, pain syndrome, spasticity, stroke

Procedia PDF Downloads 307
154 Comparing the Knee Kinetics and Kinematics during Non-Steady Movements in Recovered Anterior Cruciate Ligament Injured Badminton Players against an Uninjured Cohort: Case-Control Study

Authors: Anuj Pathare, Aleksandra Birn-Jeffery

Abstract:

Background: The Anterior Cruciate Ligament(ACL) helps stabilize the knee joint minimizing tibial anterior translation. Anterior Cruciate Ligament (ACL) injury is common in racquet sports and often occurs due to sudden acceleration, deceleration or changes of direction. This mechanism in badminton most commonly occurs during landing after an overhead stroke. Knee biomechanics during dynamic movements such as walking, running and stair negotiation, do not return to normal for more than a year after an ACL reconstruction. This change in the biomechanics may lead to re-injury whilst performing non-steady movements during sports, where these injuries are most prevalent. Aims: To compare if the knee kinetics and kinematics in ACL injury recovered athletes return to the same level as those from an uninjured cohort during standard movements used for clinical assessment and badminton shots. Objectives: The objectives of the study were to determine: Knee valgus during the single leg squat, vertical drop jump, net shot and drop shot; Degree of internal or external rotation during the single leg squat, vertical drop jump, net shot and drop shot; Maximum knee flexion during the single leg squat, vertical drop jump and net shot. Methods: This case-control study included 14 participants with three ACL injury recovered athletes and 11 uninjured participants. The participants performed various functional tasks including vertical drop jump, single leg squat; the forehand net shot and the forehand drop shot. The data was analysed using the two-way ANOVA test, and the reliability of the data was evaluated using the Intra Class Coefficient. Results: The data showed a significant decrease in the range of knee rotation in ACL injured participants as compared to the uninjured cohort (F₇,₅₅₆=2.37; p=0.021). There was also a decrease in the maximum knee flexion angles and an increase in knee valgus angles in ACL injured participants although they were not statistically significant. Conclusion: There was a significant decrease in the knee rotation angles in the ACL injured participants which could be a potential cause for re-injury in these athletes in the future. Although the results for decrease in maximum knee flexion angles and increase in knee valgus angles were not significant, this may be due to a limited sample of ACL injured participants; there is potential for it to be identified as a variable of interest in the rehabilitation of ACL injuries. These changes in the knee biomechanics could be vital in the rehabilitation of ACL injured athletes in the future, and an inclusion of sports based tasks, e.g., Net shot along with standard protocol movements for ACL assessment would provide a better measure of the rehabilitation of the athlete.

Keywords: ACL, biomechanics, knee injury, racquet sport

Procedia PDF Downloads 170
153 Altered Lower Extremity Biomechanical Risk Factor Related to Anterior Cruciate Ligament Injury in Athlete with Functional Ankle Instability

Authors: Mohammad Karimizadehardakani, Hooman Minoonejad, Reza Rajabi, Ali Sharifnejad

Abstract:

Background: Ankle sprain is one of the most important risk factor of anterior cruciate ligament (ACL) injury. Also, functional ankle instability (FAI) population has alterations in lower extremity sagittal plane biomechanics during landing task. We want to examine whether biomechanical alterations demonstrated by FAI patients are associated with the mechanism of ACL injury during high risk and sport related tasks. Methods: Sixteen basketball player with FAI and 16 non-injured control performed a single-leg cross drop landing. Knee sagittal and frontal (ATSF) was calculated. Independent t-tests, multiple linear regression, and Pearson correlation were used for analysis data. Result: Subject with FAI showed more peak ATFS, posterior ground reaction force (GRF) and less knee flexion, compared to the controls (P= 0.001, P= 0.004, P= 0.011). Knee flexion (r= −0.824, P = 0.011) and posterior GRF (r= 0.901, P = .001) were correlated with ATSF; Posterior GRF was factor that most explained the variance in ATSF (R2= 0.645; P = .001) in the FAI group. Conclusions: Result of our study showed there is a potential biomechanical relationship between the presence of FAI and risk factors associated with ACL injury mechanism.

Keywords: functional ankle instability, anterior cruciate ligament, biomechanics, risk factor

Procedia PDF Downloads 221
152 Review and Analyze on the Journal of Sport Science

Authors: Zhan Dong, Qiu Jianrong, Li Qinghui, Zhang Lei

Abstract:

The quantity and quality of the papers published on sport science from 2001 to 2013 had been counted and analysed and compared with the papers published on the journal from 1990 to 2000. The result showed that: 1. In the sports medicine field, the proportion of basic/application was abnormal. Basic research was far more than the application research. The papers on researching of imitating altitude training was the main part. Gene research made great progress.The research on sport injury and medical supervision were lower and lower. Research on sports prescription had made much progress, especially in the patients of heart infarction. 2. In building up people’s health field, the research on the old people had been more and more compared with the 10 years before, but it was not enough. 3. In the field of sports psychology, the research on disable people had been more compared with the 10 years before. Solved the problem of the sportmen before the game. 4. In the field of sports biomechanics, it showed that methods had made great progress compared with the 10 years before. Sport biomechanics combined with sports medicine, helped the sportsmen in good condition in the game. 5. In the exercise training field, the experts pay more attention to the outstanding sportsmen, and the researches emphasized that biology knowledge is the main basic for them to the research.

Keywords: sport medicine, sport injury, medical supervision

Procedia PDF Downloads 491
151 The Application of Transcranial Direct Current Stimulation (tDCS) Combined with Traditional Physical Therapy to Address Upper Limb Function in Chronic Stroke: A Case Study

Authors: Najmeh Hoseini

Abstract:

Strokerecovery happens through neuroplasticity, which is highly influenced by the environment, including neuro-rehabilitation. Transcranial direct current stimulation (tDCS) may enhance recovery by modulating neuroplasticity. With tDCS, weak direct currents are applied noninvasively to modify excitability in the cortical areas under its electrodes. Combined with functional activities, this may facilitate motor recovery in neurologic disorders such as stroke. The purpose of this case study was to examine the effect of tDCS combined with 30 minutes of traditional physical therapy (PT)on arm function following a stroke. A 29-year-old male with chronic stroke involving the left middle cerebral artery territory went through the treatment protocol. Design The design included 5 weeks of treatment: 1 week of traditional PT, 2 weeks of sham tDCS combined with traditional PT, and 2 weeks of tDCS combined with traditional PT. PT included functional electrical stimulation (FES) of wrist extensors followed by task-specific functional training. Dual hemispheric tDCS with 1 mA intensity was applied on the sensorimotor cortices for the first 20 min of the treatment combined with FES. Assessments before and after each treatment block included Modified Ashworth Scale, ChedokeMcmaster Arm and Hand inventory, Action Research Arm Test (ARAT), and the Box and Blocks Test. Results showed reduced spasticity in elbow and wrist flexors only after tDCS combination weeks (+1 to 0). The patient demonstrated clinically meaningful improvements in gross motor and fine motor control over the duration of the study; however, components of the ARAT that require fine motor control improved the greatest during the experimental block. Average time improvement compared to baseline was26.29 s for tDCS combination weeks, 18.48 s for sham tDCS, and 6.83 for PT standard of care weeks. Combining dual hemispheric tDCS with the standard of care PT demonstrated improvements in hand dexterity greater than PT alone in this patient case.

Keywords: tDCS, stroke, case study, physical therapy

Procedia PDF Downloads 90
150 WILCKO-PERIO, Periodontally Accelerated Orthodontics

Authors: Kruttika Bhuse

Abstract:

Aim: Synergism between periodontists and orthodontists (periodontal accelerated osteogenic orthodontics- PAOO) creates crucial opportunities to enhance clinical outcomes of combined therapies regarding both disciplines and has made adult orthodontics a reality. Thus, understanding the biomechanics of bone remodelling may increase the clinical applications of corticotomy facilitated orthodontics with or without alveolar augmentation. Wilckodontics can be an attractive treatment option and be a “win-win” situation for both the dental surgeon and patient by reducing the orthodontic treatment time in adults. Materials and methods: In this review, data related to the clinical aspects, steps of procedure, biomechanics of bone, indications and contraindications and final outcome of wilckodontic shall be discussed. 50 supporting articles from various international journals and 70 clinical cases were reviewed to get a better understanding to design this wilckodontic - meta analysis. Various journals like the Journal Of Clinical And Diagnostic Research, Journal Of Indian Society Of Periodontology, Journal Of Periodontology, Pubmed, Boston Orthodontic University Journal, Good Practice Orthodontics Volume 2, have been referred to attain valuable information on wilckodontics which was then compiled in this single review study. Result: As a promising adjuvant technique based on the transient nature of demineralization-remineralisation process in healthy tissues, wilckodontics consists of regional acceleratory phenomenon by alveolar corticotomy and bone grafting of labial and palatal/lingual surfaces, followed by orthodontic force. The surgical wounding of alveolar bone potentiates tissue reorganization and healing by a way of transient burst of localized hard and soft tissue remodelling.This phenomenon causes bone healing to occur 10-50 times faster than normal bone turnover. Conclusion: This meta analysis helps understanding that the biomechanics of bone remodelling may increase the clinical applications of corticotomy facilitated orthodontics with or without alveolar augmentation. The main benefits being reduced orthodontic treatment time, increased bone volume and post-orthodontic stability.

Keywords: periodontal osteogenic accelerated orthodontics, alveolar corticotomy, bone augmentation, win-win situation

Procedia PDF Downloads 385
149 A Literature Review of Ergonomics Sitting Studies to Characterize Safe and Unsafe Sitting Behaviors

Authors: Yoonjin Lee, Dongwook Hwang, Juhee Park, Woojin Park

Abstract:

As undesirable sitting posture is known to be a major cause of musculoskeletal disorder of office workers, sitting has attracted attention on occupational health. However, there seems to be no consensus on what are safe and unsafe sitting behaviors. The purpose of this study was to characterize safe and unsafe behaviors based on scientific findings of sitting behavior. Three objectives were as follows; to identify different sitting behaviors measure used in ergonomics studies on safe sitting, for each measure identified, to find available findings or recommendations on safe and unsafe sitting behaviors along with relevant empirical grounds, and to synthesize the findings or recommendations to provide characterizations of safe and unsafe behaviors. A systematic review of electronic databases (Google Scholar, PubMed, Web of Science) was conducted for extensive search of sitting behavior. Key terms included awkward sitting position, sedentary sitting, dynamic sitting, sitting posture, sitting posture, and sitting biomechanics, etc. Each article was systemically abstracted to extract a list of studied sitting behaviors, measures used to study the sitting behavior, and presence of empirical evidence of safety of the sitting behaviors. Finally, characterization of safe and unsafe sitting behavior was conducted based on knowledge with empirical evidence. This characterization is expected to provide useful knowledge for evaluation of sitting behavior and about postures to be measured in development of sensing chair.

Keywords: sitting position, sitting biomechanics, sitting behavior, unsafe sitting

Procedia PDF Downloads 297
148 Examination of Porcine Gastric Biomechanics in the Antrum Region

Authors: Sif J. Friis, Mette Poulsen, Torben Strom Hansen, Peter Herskind, Jens V. Nygaard

Abstract:

Gastric biomechanics governs a large range of scientific and engineering fields, from gastric health issues to interaction mechanisms between external devices and the tissue. Determination of mechanical properties of the stomach is, thus, crucial, both for understanding gastric pathologies as well as for the development of medical concepts and device designs. Although the field of gastric biomechanics is emerging, advances within medical devices interacting with the gastric tissue could greatly benefit from an increased understanding of tissue anisotropy and heterogeneity. Thus, in this study, uniaxial tensile tests of gastric tissue were executed in order to study biomechanical properties within the same individual as well as across individuals. With biomechanical tests in the strain domain, tissue from the antrum region of six porcine stomachs was tested using eight samples from each stomach (n = 48). The samples were cut so that they followed dominant fiber orientations. Accordingly, from each stomach, four samples were longitudinally oriented, and four samples were circumferentially oriented. A step-wise stress relaxation test with five incremental steps up to 25 % strain with 200 s rest periods for each step was performed, followed by a 25 % strain ramp test with three different strain rates. Theoretical analysis of the data provided stress-strain/time curves as well as 20 material parameters (e.g., stiffness coefficients, dissipative energy densities, and relaxation time coefficients) used for statistical comparisons between samples from the same stomach as well as in between stomachs. Results showed that, for the 20 material parameters, heterogeneity across individuals, when extracting samples from the same area, was in the same order of variation as the samples within the same stomach. For samples from the same stomach, the mean deviation percentage for all 20 parameters was 21 % and 18 % for longitudinal and circumferential orientations, compared to 25 % and 19 %, respectively, for samples across individuals. This observation was also supported by a nonparametric one-way ANOVA analysis, where results showed that the 20 material parameters from each of the six stomachs came from the same distribution with a level of statistical significance of P > 0.05. Direction-dependency was also examined, and it was found that the maximum stress for longitudinal samples was significantly higher than for circumferential samples. However, there were no significant differences in the 20 material parameters, with the exception of the equilibrium stiffness coefficient (P = 0.0039) and two other stiffness coefficients found from the relaxation tests (P = 0.0065, 0.0374). Nor did the stomach tissue show any significant differences between the three strain-rates used in the ramp test. Heterogeneity within the same region has not been examined earlier, yet, the importance of the sampling area has been demonstrated in this study. All material parameters found are essential to understand the passive mechanics of the stomach and may be used for mathematical and computational modeling. Additionally, an extension of the protocol used may be relevant for compiling a comparative study between the human stomach and the pig stomach.

Keywords: antrum region, gastric biomechanics, loading-unloading, stress relaxation, uniaxial tensile testing

Procedia PDF Downloads 426
147 Biomechanical Study of a Type II Superior Labral Anterior to Posterior Lesion in the Glenohumeral Joint Using Finite Element Analysis

Authors: Javier A. Maldonado E., Duvert A. Puentes T., Diego F. Villegas B.

Abstract:

The SLAP lesion (Superior Labral Anterior to Posterior) involves the labrum, causing pain and mobility problems in the glenohumeral joint. This injury is common in athletes practicing sports that requires throwing or those who receive traumatic impacts on the shoulder area. This paper determines the biomechanical behavior of soft tissues of the glenohumeral joint when type II SLAP lesion is present. This pathology is characterized for a tear in the superior labrum which is simulated in a 3D model of the shoulder joint. A 3D model of the glenohumeral joint was obtained using the free software Slice. Then, a Finite Element analysis was done using a general purpose software which simulates a compression test with external rotation. First, a validation was done assuming a healthy joint shoulder with a previous study. Once the initial model was validated, a lesion of the labrum built using a CAD software and the same test was done again. The results obtained were stress and strain distribution of the synovial capsule and the injured labrum. ANOVA was done for the healthy and injured glenohumeral joint finding significant differences between them. This study will help orthopedic surgeons to know the biomechanics involving this type of lesion and also the other surrounding structures affected by loading the injured joint.

Keywords: biomechanics, computational model, finite elements, glenohumeral joint, superior labral anterior to posterior lesion

Procedia PDF Downloads 200
146 Thermography Evaluation on Facial Temperature Recovery after Elastic Gum

Authors: A. Dionísio, L. Roseiro, J. Fonseca, P. Nicolau

Abstract:

Thermography is a non-radiating and contact-free technology which can be used to monitor skin temperature. The efficiency and safety of thermography technology make it a useful tool for detecting and locating thermal changes in skin surface, characterized by increases or decreases in temperature. This work intends to be a contribution for the use of thermography as a methodology for evaluation of skin temperature in the context of orofacial biomechanics. The study aims to identify the oscillations of skin temperature in the left and right hemiface regions of the masseter muscle, during and after thermal stimulus, and estimate the time required to restore the initial temperature after the application of the stimulus. Using a FLIR T430sc camera, a data acquisition protocol was followed with a group of eight volunteers, aged between 22 and 27 years. The tests were performed in a controlled environment with the volunteers in a comfortably static position. The thermal stimulus involves the use of an ice volume with controlled size and contact surface. The skin surface temperature was recorded in two distinct situations, namely without further stimulus and with the additions of a stimulus obtained by a chewing gum. The data obtained were treated using FLIR Research IR Max software. The time required to recover the initial temperature ranged from 20 to 52 minutes when no stimulus was added and varied between 8 and 26 minutes with the chewing gum stimulus. These results show that recovery is faster with the addition of the stimulus and may guide clinicians regarding the pre and post-operative times with ice therapy, in the presence or absence of mechanical stimulus that increases muscle functions (e.g. phonetics or mastication).

Keywords: thermography, orofacial biomechanics, skin temperature, ice therapy

Procedia PDF Downloads 251
145 The Curvature of Bending Analysis and Motion of Soft Robotic Fingers by Full 3D Printing with MC-Cells Technique for Hand Rehabilitation

Authors: Chaiyawat Musikapan, Ratchatin Chancharoen, Saknan Bongsebandhu-Phubhakdi

Abstract:

For many recent years, soft robotic fingers were used for supporting the patients who had survived the neurological diseases that resulted in muscular disorders and neural network damages, such as stroke and Parkinson’s disease, and inflammatory symptoms such as De Quervain and trigger finger. Generally, the major hand function is significant to manipulate objects in activities of daily living (ADL). In this work, we proposed the model of soft actuator that manufactured by full 3D printing without the molding process and one material for use. Furthermore, we designed the model with a technique of multi cavitation cells (MC-Cells). Then, we demonstrated the curvature bending, fluidic pressure and force that generated to the model for assistive finger flexor and hand grasping. Also, the soft actuators were characterized in mathematics solving by the length of chord and arc length. In addition, we used an adaptive push-button switch machine to measure the force in our experiment. Consequently, we evaluated biomechanics efficiency by the range of motion (ROM) that affected to metacarpophalangeal joint (MCP), proximal interphalangeal joint (PIP) and distal interphalangeal joint (DIP). Finally, the model achieved to exhibit the corresponding fluidic pressure with force and ROM to assist the finger flexor and hand grasping.

Keywords: biomechanics efficiency, curvature bending, hand functional assistance, multi cavitation cells (MC-Cells), range of motion (ROM)

Procedia PDF Downloads 255
144 Analysis in Mexico on Workers Performing Highly Repetitive Movements with Sensory Thermography in the Surface of the Wrist and Elbows

Authors: Sandra K. Enriquez, Claudia Camargo, Jesús E. Olguín, Juan A. López, German Galindo

Abstract:

Currently companies have increased the number of disorders of cumulative trauma (CTDs), these are increasing significantly due to the Highly Repetitive Movements (HRM) performed in workstations, which causes economic losses to businesses, due to temporary and permanent disabilities of workers. This analysis focuses on the prevention of disorders caused by: repeatability, duration and effort; And focuses on reducing cumulative trauma disorders such as occupational diseases using sensory thermography as a noninvasive method, the above is to evaluate the injuries could have workers to perform repetitive motions. Objectives: The aim is to define rest periods or job rotation before they generate a CTD, this sensory thermography by analyzing changes in temperature patterns on wrists and elbows when the worker is performing HRM over a period of time 2 hours and 30 minutes. Information on non-work variables such as wrist and elbow injuries, weight, gender, age, among others, and work variables such as temperature workspace, repetitiveness and duration also met. Methodology: The analysis to 4 industrial designers, 2 men and 2 women to be specific was conducted in a business in normal health for a period of 12 days, using the following time ranges: the first day for every 90 minutes continuous work were asked to rest 5 minutes, the second day for every 90 minutes of continuous work were asked to rest 10 minutes, the same to work 60 and 30 minutes straight. Each worker was tested with 6 different ranges at least twice. This analysis was performed in a controlled room temperature between 20 and 25 ° C, and a time to stabilize the temperature of the wrists and elbows than 20 minutes at the beginning and end of the analysis. Results: The range time of 90 minutes working continuous and a rest of 5 minutes of activity is where the maximum temperature (Tmax) was registered in the wrists and elbows in the office, we found the Tmax was 35.79 ° C with a difference of 2.79 ° C between the initial and final temperature of the left elbow presented at the individual 4 during the 86 minutes, in of range in 90 minutes continuously working and rested for 5 minutes of your activity. Conclusions: It is possible with this alternative technology is sensory thermography predict ranges of rotation or rest for the prevention of CTD to perform HRM work activities, obtaining with this reduce occupational disease, quotas by health agencies and increasing the quality of life of workers, taking this technology a cost-benefit acceptable in the future.

Keywords: sensory thermography, temperature, cumulative trauma disorder (CTD), highly repetitive movement (HRM)

Procedia PDF Downloads 425
143 Investigation of the Relationship between Digital Game Playing, Internet Addiction and Perceived Stress Levels in University Students

Authors: Sevim Ugur, Cemile Kutmec Yilmaz, Omer Us, Sevdenur Koksaldi

Abstract:

Aim: This study aims to investigate the effect of digital game playing and Internet addiction on perceived stress levels in university students. Method: The descriptive study was conducted through face-to-face interview method with a total of 364 university students studying at Aksaray University between November 15 and December 30, 2017. The research data were collected using personal information form, a questionnaire to determine the characteristics of playing digital game, the Internet addiction scale and the perceived stress scale. In the evaluation of the data, Mann-Whitney U test was used for two-group comparison of the sample with non-normal distribution, Kruskal-Wallis H-test was used in the comparison of more than two groups, and the Spearman correlation test was used to determine the relationship between Internet addiction and the perceived stress level. Results: It was determined that the mean age of the students participated in the study was 20.13 ± 1.7 years, 67.6% was female, 35.7% was sophomore, and 62.1% had an income 500 TL or less. It was found that 83.5% of the students use the Internet every day and 70.6% uses the Internet for 5 hours or less per day. Of the students, 12.4% prefers digital games instead of spending time outdoors, 8% plays a game as the first activity in leisure time, 12.4% plays all day, 15.7% feels anger when he/she is prevented from playing, 14.8% prefers playing games to get away from his/her problems, 23.4% had his/her school achievement affected negatively because of game playing, and 8% argues with family members due to the time spent for gaming. Students who play games on the computer for a long time were found to feel back pain (30.8%), headache (28.6%), insomnia (26.9%), dryness and pain in the eyes (26.6%), pain in the wrist (21.2%), feeling excessive tension and anger (16.2%), humpback (12.9), vision loss (9.6%) and pain in the wrist and fingers (7.4%). In our study, students' Internet addiction scale mean score was found to be 45.47 ± 16.1 and mean perceived stress scale score was 28.56 ± 2.7. A significant and negative correlation (p=0.037) was found between the total score of the Internet addiction scale and the total score of the perceived stress scale (r=-0.110). Conclusion: It was found in the study that Internet addiction and perceived stress of the students were at a moderate level and that there was a negative correlation between Internet addiction and perceived stress levels. Internet addiction was found to increase with the increasing perceived stress levels of students, and students were found to have health problems such as back pain, dryness in the eyes, pain, insomnia, headache, and humpback. Therefore, it is recommended to inform students about different coping methods other than spending time on the Internet to cope with the stress they perceive.

Keywords: digital game, internet addiction, student, stress level

Procedia PDF Downloads 287
142 Optimization Parameters Using Response Surface Method on Biomechanical Analysis for Malaysian Soccer Players

Authors: M. F. M. Ali, A. R. Ismail, B. M. Deros

Abstract:

Soccer is very popular and ranked as the top sports in the world as well as in Malaysia. Although soccer sport in Malaysia is currently professionalized, but it’s plunging achievements within recent years continue and are not to be proud of. After review, the Malaysian soccer players are still weak in terms of kicking techniques. The instep kick is a technique, which is often used in soccer for the purpose of short passes and making a scoring. This study presents the 3D biomechanics analysis on a soccer player during performing instep kick. This study was conducted to determine the optimization value for approach angle, distance of supporting leg from the ball and ball internal pressure respect to the knee angular velocity of the ball on the kicking leg. Six subjects from different categories using dominant right leg and free from any injury were selected to take part in this study. Subjects were asked to perform one step instep kick according to the setting for the variables with different parameter. Data analysis was performed using 3 Dimensional “Qualisys Track Manager” system and will focused on the bottom of the body from the waist to the ankle. For this purpose, the marker will be attached to the bottom of the body before the kicking is perform by the subjects. Statistical analysis was conducted by using Minitab software using Response Surface Method through Box-Behnken design. The results of this study found the optimization values for all three parameters, namely the approach angle, 53.6º, distance of supporting leg from the ball, 8.84sm and ball internal pressure, 0.9bar with knee angular velocity, 779.27 degrees/sec have been produced.

Keywords: biomechanics, instep kick, soccer, optimization

Procedia PDF Downloads 229
141 Work Related Musculoskeletal Disorder: A Case Study of Office Computer Users in Nigerian Content Development and Monitoring Board, Yenagoa, Bayelsa State, Nigeria

Authors: Tamadu Perry Egedegu

Abstract:

Rapid growth in the use of electronic data has affected both the employee and work place. Our experience shows that jobs that have multiple risk factors have a greater likelihood of causing Work Related Musculoskeletal Disorder (WRMSDs), depending on the duration, frequency and/or magnitude of exposure to each. The study investigated musculoskeletal disorder among office workers. Thus, it is important that ergonomic risk factors be considered in light of their combined effect in causing or contributing to WRMSDs. Fast technological growth in the use of electronic system; have affected both workers and the work environment. Awkward posture and long hours in front of these visual display terminals can result in work-related musculoskeletal disorders (WRMSD). The study shall contribute to the awareness creation on the causes and consequences of WRMSDs due to lack of ergonomics training. The study was conducted using an observational cross-sectional design. A sample of 109 respondents was drawn from the target population through purposive sampling method. The sources of data were both primary and secondary. Primary data were collected through questionnaires and secondary data were sourced from journals, textbooks, and internet materials. Questionnaires were the main instrument for data collection and were designed in a YES or NO format according to the study objectives. Content validity approval was used to ensure that the variables were adequately covered. The reliability of the instrument was done through test-retest method, yielding a reliability index at 0.84. The data collected from the field were analyzed with a descriptive statistics of chart, percentage and mean. The study found that the most affected body regions were the upper back, followed by the lower back, neck, wrist, shoulder and eyes, while the least affected body parts were the knee calf and the ankle. Furthermore, the prevalence of work-related 'musculoskeletal' malfunctioning was linked with long working hours (6 - 8 hrs.) per day, lack of back support on their seats, glare on the monitor, inadequate regular break, repetitive motion of the upper limbs, and wrist when using the computer. Finally, based on these findings some recommendations were made to reduce the prevalent of WRMSDs among office workers.

Keywords: work related musculoskeletal disorder, Nigeria, office computer users, ergonomic risk factor

Procedia PDF Downloads 235
140 A Multi Function Myocontroller for Upper Limb Prostheses

Authors: Ayad Asaad Ibrahim

Abstract:

Myoelectrically controlled prostheses are becoming more and more popular, for below-elbow amputation, the wrist flexor and extensor muscle group, while for above-elbow biceps and triceps brachii muscles are used for control of the prosthesis. A two site multi-function controller is presented. Two stainless steel bipolar electrode pairs are used to monitor the activities in both muscles. The detected signals are processed by new pre-whitening technique to identify the accurate tension estimation in these muscles. These estimates will activate the relevant prosthesis control signal, with a time constant of 200 msec. It is ensured that the tension states in the control muscle to activate a particular prosthesis function are similar to those used to activate normal functions in the natural hand. This facilitates easier training.

Keywords: prosthesis, biosignal processing, pre-whitening, myoelectric controller

Procedia PDF Downloads 362
139 Biosignal Measurement System Based on Ultra-Wide Band Human Body Communication

Authors: Jonghoon Kim, Gilwon Yoon

Abstract:

A wrist-band type biosignal measurement system and its data transfer through human body communication (HBC) were investigated. An HBC method based on pulses of ultra-wide band instead of using frequency or amplitude modulations was studied and implemented since the system became very compact and it was more suited for personal or mobile health monitoring. Our system measured photo-plethysmogram (PPG) and measured PPG signals were transmitted through a finger to a monitoring PC system. The device was compact and low-power consuming. HBC communication has very strong security measures since it does not use wireless network. Furthermore, biosignal monitoring system becomes handy because it does not need to have wire connections.

Keywords: biosignal, human body communication, mobile health, PPG, ultrawide band

Procedia PDF Downloads 469
138 Physics’s Practical Based on Android as a Motivator in Learning Physics

Authors: Yuni Rochmawati, Luluk Il Mukarromah

Abstract:

Android is a mobile operating system (OS) based on the linux kerrnel and currently developed by google. With a user interface based on direct manipulation, Android is designed primarily for touchscreen mobile deviced such as smartphone and tablet computer, with specialized user interface for television (Android TV), cars (Android Auto), and wrist watches (Android Wear). Now, almost all peoples using smartphone. Smartphone seems to be a must-have object, because smartphone has many benefits. In addition, of course smartphone have many benefits for education, like resume of lesson that form of e-book. However, this article is not about resume of lesson. This article is about practical based on android, exactly for physics. Therefore, we will explain our idea about physics’s practical based on android and for output, we wish many students will be like to studying physics and always remember about physics’s phenomenon by physics’s practical based on android.

Keywords: android, smartphone, physics, practical

Procedia PDF Downloads 236
137 Improvement of an Arm and Shoulder Exoskeleton Using Gyro Sensor

Authors: D. Maneetham

Abstract:

The developed exoskeleton device has to control joints between shoulder and arm. Exoskeleton device can help patients with hemiplegia upper so that the patient can help themselves in their daily life. Exoskeleton device includes a robot arm wear that looks like the movement is similar to the normal arm. Exoskeleton arm is powered by the motor through the cable with a control system that developed to control the movement of the joint of a robot arm. The arm will include the shoulder, the elbow, and the wrist. The control system is used Arduino Mega 2560 controller and the operation of the DC motor through the relay module. The control system can be divided into two modes such as the manual control with the joystick mode and automatically control with the movement of the head by Gyro sensor. The controller is also designed to move between the shoulder and the arm movement from their original location. Results have shown that the controller gave the best performance and all movements can be controlled.

Keywords: exoskeleton arm, hemiplegia upper, shoulder and arm, stroke

Procedia PDF Downloads 350
136 Biomechanics of Ceramic on Ceramic vs. Ceramic on Xlpe Total Hip Arthroplasties During Gait

Authors: Athanasios Triantafyllou, Georgios Papagiannis, Vassilios Nikolaou, Panayiotis J. Papagelopoulos, George C. Babis

Abstract:

In vitro measurements are widely used in order to predict THAs wear rate implementing gait kinematic and kinetic parameters. Clinical tests of materials and designs are crucial to prove the accuracy and validate such measurements. The purpose of this study is to examine the affection of THA gait kinematics and kinetics on wear during gait, the essential functional activity of humans, by comparing in vivo gait data to in vitro results. Our study hypothesis is that both implants will present the same hip joint kinematics and kinetics during gait. 127 unilateral primary cementless total hip arthroplasties were included in the research. Independent t-tests were used to identify a statistically significant difference in kinetic and kinematic data extracted from 3D gait analysis. No statistically significant differences observed at mean peak abduction, flexion and extension moments between the two groups (P.abduction= 0,125, P.flexion= 0,218, P.extension= 0,082). The kinematic measurements show no statistically significant differences too (Prom flexion-extension= 0,687, Prom abduction-adduction= 0,679). THA kinematics and kinetics during gait are important biomechanical parameters directly associated with implants wear. In vitro studies report less wear in CoC than CoXLPE when tested with the same gait cycle kinematic protocol. Our findings confirm that both implants behave identically in terms of kinematics in the clinical environment, thus strengthening in vitro results of CoC advantage. Correlated to all other significant factors that affect THA wear could address in a complete prism the wear on CoC and CoXLPE.

Keywords: total hip arthroplasty biomechanics, THA gait analysis, ceramic on ceramic kinematics, ceramic on XLPE kinetics, total hip replacement wear

Procedia PDF Downloads 146
135 An Unusual Fracture Pattern: Fracture of the Distal Radius (Colles') along with Fracture of the Ipsilateral Scaphoid & Capitate Bones

Authors: Srikanta Tagore Sarkar, Prasanta Kumar Mandal, Dibakar Roy

Abstract:

The association of a capitate fracture with a scaphoid fracture has been termed as the naviculocapitate syndrome. The existence of some nondisplaced fractures of scaphoid and capitate with or without the fracture of lunate or radius suggests that there is a spectrum of these injuries, and this confuses the terminology. With our case; we report an unusual variety of this naviculocapitate syndrome with distal radial Colles fracture in addition to the nondisplaced fractures of the scaphoid, capitate and the dorsal lip of radial fracture. When we looked at the literature there is no another Colles fracture reported together with undisplaced scapho-capitate syndrome. The coronal and sagittal images that obtained from the MDCT (Multidetector computed tomography) is useful and effective imaging modality to diagnose complex wrist fractures with more details that are not detected in X-rays.

Keywords: scaphoid, capitate, Colles’ fracture, syndrome, MDCT, unusual

Procedia PDF Downloads 388
134 Perception of Tactile Stimuli in Children with Autism Spectrum Disorder

Authors: Kseniya Gladun

Abstract:

Tactile stimulation of a dorsal side of the wrist can have a strong impact on our attitude toward physical objects such as pleasant and unpleasant impact. This study explored different aspects of tactile perception to investigate atypical touch sensitivity in children with autism spectrum disorder (ASD). This study included 40 children with ASD and 40 healthy children aged 5 to 9 years. We recorded rsEEG (sampling rate of 250 Hz) during 20 min using EEG amplifier “Encephalan” (Medicom MTD, Taganrog, Russian Federation) with 19 AgCl electrodes placed according to the International 10–20 System. The electrodes placed on the left, and right mastoids served as joint references under unipolar montage. The registration of EEG v19 assignments was carried out: frontal (Fp1-Fp2; F3-F4), temporal anterior (T3-T4), temporal posterior (T5-T6), parietal (P3-P4), occipital (O1-O2). Subjects were passively touched by 4 types of tactile stimuli on the left wrist. Our stimuli were presented with a velocity of about 3–5 cm per sec. The stimuli materials and procedure were chosen for being the most "pleasant," "rough," "prickly" and "recognizable". Type of tactile stimulation: Soft cosmetic brush - "pleasant" , Rough shoe brush - "rough", Wartenberg pin wheel roller - "prickly", and the cognitive tactile stimulation included letters by finger (most of the patient’s name ) "recognizable". To designate the moments of the stimuli onset-offset, we marked the moment when the moment of the touch began and ended; the stimulation was manual, and synchronization was not precise enough for event-related measures. EEG epochs were cleaned from eye movements by ICA-based algorithm in EEGLAB plugin for MatLab 7.11.0 (Mathwork Inc.). Muscle artifacts were cut out by manual data inspection. The response to tactile stimuli was significantly different in the group of children with ASD and healthy children, which was also depended on type of tactile stimuli and the severity of ASD. Amplitude of Alpha rhythm increased in parietal region to response for only pleasant stimulus, for another type of stimulus ("rough," "thorny", "recognizable") distinction of amplitude was not observed. Correlation dimension D2 was higher in healthy children compared to children with ASD (main effect ANOVA). In ASD group D2 was lower for pleasant and unpleasant compared to the background in the right parietal area. Hilbert transform changes in the frequency of the theta rhythm found only for a rough tactile stimulation compared with healthy participants only in the right parietal area. Children with autism spectrum disorders and healthy children were responded to tactile stimulation differently with specific frequency distribution alpha and theta band in the right parietal area. Thus, our data supports the hypothesis that rsEEG may serve as a sensitive index of altered neural activity caused by ASD. Children with autism have difficulty in distinguishing the emotional stimuli ("pleasant," "rough," "prickly" and "recognizable").

Keywords: autism, tactile stimulation, Hilbert transform, pediatric electroencephalography

Procedia PDF Downloads 249
133 Development and Validation of Work Movement Task Analysis: Part 1

Authors: Mohd Zubairy Bin Shamsudin

Abstract:

Work-related Musculoskeletal Disorder (WMSDs) is one of the occupational health problems encountered by workers over the world. In Malaysia, there is increasing in trend over the years, particularly in the manufacturing sectors. Current method to observe workplace WMSDs is self-report questionnaire, observation and direct measurement. Observational method is most frequently used by the researcher and practitioner because of the simplified, quick and versatile when it applies to the worksite. However, there are some limitations identified e.g. some approach does not cover a wide spectrum of biomechanics activity and not sufficiently sensitive to assess the actual risks. This paper elucidates the development of Work Movement Task Analysis (WMTA), which is an observational tool for industrial practitioners’ especially untrained personnel to assess WMSDs risk factors and provide a basis for suitable intervention. First stage of the development protocol involved literature reviews, practitioner survey, tool validation and reliability. A total of six themes/comments were received in face validity stage. New revision of WMTA consisted of four sections of postural (neck, back, shoulder, arms, and legs) and associated risk factors; movement, load, coupling and basic environmental factors (lighting, noise, odorless, heat and slippery floor). For inter-rater reliability study shows substantial agreement among rater with K = 0.70. Meanwhile, WMTA validation shows significant association between WMTA score and self-reported pain or discomfort for the back, shoulder&arms and knee&legs with p<0.05. This tool is expected to provide new workplace ergonomic observational tool to assess WMSDs for the next stage of the case study.

Keywords: assessment, biomechanics, musculoskeletal disorders, observational tools

Procedia PDF Downloads 466
132 Development of a Biomechanical Method for Ergonomic Evaluation: Comparison with Observational Methods

Authors: M. Zare, S. Biau, M. Corq, Y. Roquelaure

Abstract:

A wide variety of observational methods have been developed to evaluate the ergonomic workloads in manufacturing. However, the precision and accuracy of these methods remain a subject of debate. The aims of this study were to develop biomechanical methods to evaluate ergonomic workloads and to compare them with observational methods. Two observational methods, i.e. SCANIA Ergonomic Standard (SES) and Rapid Upper Limb Assessment (RULA), were used to assess ergonomic workloads at two simulated workstations. They included four tasks such as tightening & loosening, attachment of tubes and strapping as well as other actions. Sensors were also used to measure biomechanical data (Inclinometers, Accelerometers, and Goniometers). Our findings showed that in assessment of some risk factors both RULA & SES were in agreement with the results of biomechanical methods. However, there was disagreement on neck and wrist postures. In conclusion, the biomechanical approach was more precise than observational methods, but some risk factors evaluated with observational methods were not measurable with the biomechanical techniques developed.

Keywords: ergonomic, observational method, biomechanical methods, workload

Procedia PDF Downloads 386
131 Variations in the Angulation of the First Sacral Spinous Process Angle Associated with Sacrocaudal Fusion in Greyhounds

Authors: Sa'ad M. Ismail, Hung-Hsun Yen, Christina M. Murray, Helen M. S. Davies

Abstract:

In the dog, the median sacral crest is formed by the fusion of three sacral spinous processes. In greyhounds with standard sacrums, this fusion in the median sacral crest consists of the fusion of three sacral spinous processes while it consists of four in greyhounds with sacrocaudal fusion. In the present study, variations in the angulation of the first sacral spinous process in association with different types of sacrocaudal fusion in the greyhound were investigated. Sacrums were collected from 207 greyhounds (102 sacrums; type A (unfused) and 105 with different types of sacrocaudal fusion; types: B, C and D). Sacrums were cleaned by boiling and dried and then were placed on their ventral surface on a flat surface and photographed from the left side using a digital camera at a fixed distance. The first sacral spinous process angle (1st SPA) was defined as the angle formed between the cranial border of the cranial ridge of the first sacral spinous process and the line extending across the most dorsal surface points of the spinous processes of the S1, S2, and S3. Image-Pro Express Version 5.0 imaging software was used to draw and measure the angles. Two photographs were taken for each sacrum and two repeat measurements were also taken of each angle. The mean value of the 1st SPA in greyhounds with sacrocaudal fusion was less (98.99°, SD ± 11, n = 105) than those in greyhounds with standard sacrums (99.77°, SD ± 9.18, n = 102) but was not significantly different (P < 0.05). Among greyhounds with different types of sacrocaudal fusion the mean value of the 1st SPA was as follows: type B; 97.73°, SD ± 10.94, n = 39, type C: 101.42°, SD ± 10.51, n = 52, and type D: 94.22°, SD ± 11.30, n = 12. For all types of fusion these angles were significantly different from each other (P < 0.05). Comparing the mean value of the1st SPA in standard sacrums (Type A) with that for each type of fusion separately showed that the only significantly different angulation (P < 0.05) was between standard sacrums and sacrums with sacrocaudal fusion sacrum type D (only body fusion between the S1 and Ca1). Different types of sacrocaudal fusion were associated with variations in the angle of the first sacral spinous process. These variations may affect the alignment and biomechanics of the sacral area and the pattern of movement and/or the force produced by both hind limbs to the cranial parts of the body and may alter the loading of other parts of the body. We concluded that any variations in the sacrum anatomical features might change the function of the sacrum or surrounding anatomical structures during movement.

Keywords: angulation of first sacral spinous process, biomechanics, greyhound, locomotion, sacrocaudal fusion

Procedia PDF Downloads 308
130 Smoker Recognition from Lung X-Ray Images Using Convolutional Neural Network

Authors: Moumita Chanda, Md. Fazlul Karim Patwary

Abstract:

Smoking is one of the most popular recreational drug use behaviors, and it contributes to birth defects, COPD, heart attacks, and erectile dysfunction. To completely eradicate this disease, it is imperative that it be identified and treated. Numerous smoking cessation programs have been created, and they demonstrate how beneficial it may be to help someone stop smoking at the ideal time. A tomography meter is an effective smoking detector. Other wearables, such as RF-based proximity sensors worn on the collar and wrist to detect when the hand is close to the mouth, have been proposed in the past, but they are not impervious to deceptive variables. In this study, we create a machine that can discriminate between smokers and non-smokers in real-time with high sensitivity and specificity by watching and collecting the human lung and analyzing the X-ray data using machine learning. If it has the highest accuracy, this machine could be utilized in a hospital, in the selection of candidates for the army or police, or in university entrance.

Keywords: CNN, smoker detection, non-smoker detection, OpenCV, artificial Intelligence, X-ray Image detection

Procedia PDF Downloads 79
129 Accuracy of Fitbit Charge 4 for Measuring Heart Rate in Parkinson’s Patients During Intense Exercise

Authors: Giulia Colonna, Jocelyn Hoye, Bart de Laat, Gelsina Stanley, Jose Key, Alaaddin Ibrahimy, Sule Tinaz, Evan D. Morris

Abstract:

Parkinson’s disease (PD) is the second most common neurodegenerative disease and affects approximately 1% of the world’s population. Increasing evidence suggests that aerobic physical exercise can be beneficial in mitigating both motor and non-motor symptoms of the disease. In a recent pilot study of the role of exercise on PD, we sought to confirm exercise intensity by monitoring heart rate (HR). For this purpose, we asked participants to wear a chest strap heart rate monitor (Polar Electro Oy, Kempele). The device sometimes proved uncomfortable. Looking forward to larger clinical trials, it would be convenient to employ a more comfortable and user friendly device. The Fitbit Charge 4 (Fitbit Inc) is a potentially comfortable, user-friendly solution since it is a wrist-worn heart rate monitor. Polar H10 has been used in large trials, and for our purposes, we treated it as the gold standard for the beat-to-beat period (R-R interval) assessment. In previous literature, it has been shown that Fitbit Charge 4 has comparable accuracy to Polar H10 in healthy subjects. It has yet to be determined if the Fitbit is as accurate as the Polar H10 in subjects with PD or in clinical populations, generally. Goal: To compare the Fitbit Charge 4 to the Polar H10 for monitoring HR in PD subjects engaging in an intensive exercise program. Methods: A total of 596 exercise sessions from 11 subjects (6 males) were collected simultaneously by both devices. Subjects with early-stage PD (Hoehn & Yahr <=2) were enrolled in a 6 months exercise training program designed for PD patients. Subjects participated in 3 one-hour exercise sessions per week. They wore both Fitbit and Polar H10 during each session. Sessions included rest, warm-up, intensive exercise, and cool-down periods. We calculated the bias in the HR via Fitbit under rest (5min) and intensive exercise (20min) by comparing the mean HR during each of the periods to the respective means measured by the Polar (HRFitbit – HRPolar). We also measured the sensitivity and specificity of Fitbit for detecting HRs that exceed the threshold for intensive exercise, defined as 70% of an individual’s theoretical maximum HR. Different types of correlation between the two devices were investigated. Results: The mean bias was 1.68 bpm at rest and 6.29 bpm during high intensity exercise, with an overestimation by Fitbit in both conditions. The mean bias of Fitbit across both rest and intensive exercise periods was 3.98 bpm. The sensitivity of the device in identifying high intensity exercise sessions was 97.14 %. The correlation between the two devices was non-linear, suggesting a saturation tendency of Fitbit to saturate at high values of HR. Conclusion: The performance of Fitbit Charge 4 is comparable to Polar H10 for assessing exercise intensity in a cohort of PD subjects. The device should be considered a reasonable replacement for the more cumbersome chest strap technology in future similar studies of clinical populations.

Keywords: fitbit, heart rate measurements, parkinson’s disease, wrist-wearable devices

Procedia PDF Downloads 103
128 Application of Sensory Thermography on Workers of a Wireless Industry in Mexico

Authors: Claudia Camargo Wilson, Enrique Javier de la Vega Bustillos, Jesús Everardo Olguín Tiznado, Juan Andrés López Barreras, Sandra K. Enriquez

Abstract:

This study focuses on the application of sensory thermography, as a non-invasive method to evaluate the musculoskeletal injuries that industry workers performing Highly Repetitive Movements (HRM) may acquire. It was made at a wireless company having the target of analyze temperatures in worker’s wrists, elbows and shoulders in workstations during their activities, this thru sensorial thermography with the goal of detecting maximum temperatures (Tmax) that could indicate possible injuries. The tests were applied during 3 hours for only 2 workers that work in workstations where there’s been the highest index of injuries and accidents. We were made comparisons for each part of the body that were study for both because of the similitude between the activities of the workstations; they were requiring both an immediate evaluation. The Tmax was recorder during the test of the worker 2, in the left wrist, reaching a temperature of 35.088ºC and with a maximum increase of 1.856°C.

Keywords: thermography, maximum temperaturas (Tmax), highly repetitive movements (HRM), operator

Procedia PDF Downloads 398