Search results for: daughter cavity
63 The Evaluation of the Impact of Tobacco Heating System and Conventional Cigarette Smoking on Self Reported Oral Symptoms (Dry Mouth, Halitosis, Burning Sensation, Taste Changes) and Salivary Flow Rate: A Cross-sectional Study
Authors: Ella Sever, Irena Glažar, Ema Saltović
Abstract:
Conventional cigarette smoking is associated with an increased risk of oral diseases and oral symptoms such as dry mouth, bad breath, burning sensation, and changes in taste sensation. The harmful effects of conventional cigarette smoking on oral health have been extensively studied previously. However, there is a severe lack of studies investigating the effects of Tobacco Heating System (THS) on oral structures. As a preventive measure, a new alternative Tobacco THS has been developed, and according to the manufacturer, it has fewer potentially harmful and harmful constituents and consequently, lowers the risk of developing tobacco-related diseases. The aim is to analyze the effects of conventional cigarettes and THS on salivary flow rate (SFR), and self-reported oral symptoms.The stratified cross-sectional study included 90 subjects divided into three groups: THS smokers, conventional cigarette smokers, and nonsmokers. The subjects completed questionnaires on smoking habits, and symptoms (dry mouth, bad breath, burning sensation, and changes in taste sensation). SFR test were performed on each subject. The lifetime exposure to smoking was calculated using the Brinkman index (BI). Participants were 20-55 years old (median 31), and 66.67 % were female. The study included three groups of equal size (n = 20), and no statistically significant differences were found between the groups in terms of age (p = 0.632), sex (p = 1.0), and lifetime exposure to smoking (the BI) (p=0,129). Participants from the smoking group had an average of 10 (2-30) years of smoking experience in the conventional cigarettes group and 6 (1-20) years of smoking experience in the THS group. Daily consumption of cigarettes/heets per day was the same for both smokers’ groups (12(2-20) cigarettes/heets per day). The self-reported symptoms were present in 40 % of participants in the smokers group. There were significant differences in the presence of halitosis (p = 0.025) and taste sensation (p=0.013). There were no statistical differences in the presence of dry mouth (p =0.416) and burning sensation (0.7). The SFR differed between groups (p < 0.001) and was significantly lower in the THS and conventional cigarette smokers’ groups than the nonsmokers’ group. There were no significant differences between THS smokers and conventional cigarette smokers. The results of the study show that THS products have a similar effect to conventional cigarettes on oral cavity structures, especially in terms of SFR, self-reported halitosis, and changes in taste.Keywords: oral health, tobacco products, halitosis, cigarette smoking
Procedia PDF Downloads 6162 Designing Electrically Pumped Photonic Crystal Surface Emitting Lasers Based on a Honeycomb Nanowire Pattern
Authors: Balthazar Temu, Zhao Yan, Bogdan-Petrin Ratiu, Sang Soon Oh, Qiang Li
Abstract:
Photonic crystal surface emitting lasers (PCSELs) has recently become an area of active research because of the advantages these lasers have over the edge emitting lasers and vertical cavity surface emitting lasers (VCSELs). PCSELs can emit laser beams with high power (from the order of few milliwatts to Watts or even tens of Watts) which scales with the emission area while maintaining single mode operation even at large emission areas. Most PCSELs reported in the literature are air-hole based, with only few demonstrations of nanowire based PCSELs. We previously reported an optically pumped, nanowire based PCSEL operating in the O band by using the honeycomb lattice. The nanowire based PCSELs have the advantage of being able to grow on silicon platform without threading dislocations. It is desirable to extend their operating wavelength to C band to open more applications including eye-safe sensing, lidar and long haul optical communications. In this work we first analyze how the lattice constant , nanowire diameter, nanowire height and side length of the hexagon in the honeycomb pattern can be changed to increase the operating wavelength of the honeycomb based PCSELs to the C band. Then as an attempt to make our device electrically pumped, we present the finite-difference time-domain (FDTD) simulation results with metals on the nanowire. The results for different metals on the nanowire are presented in order to choose the metal which gives the device with the best quality factor. The metals under consideration are those which form good ohmic contact with p-type doped InGaAs with low contact resistivity and decent sticking coefficient to the semiconductor. Such metals include Tungsten, Titanium, Palladium and Platinum. Using the chosen metal we demonstrate the impact of thickness of the metal for a given nanowire height on the quality factor of the device. We also investigate how the height of the nanowire affects the quality factor for a fixed thickness of the metal. Finally, the main steps in making the practical device are discussed.Keywords: designing nanowire PCSEL, designing PCSEL on silicon substrates, low threshold nanowire laser, simulation of photonic crystal lasers.
Procedia PDF Downloads 1761 Evaluating the Factors That Influence Caries Reduction During Pregnancy
Authors: Mimoza Canga, Irene Malagnino, Vergjini Mulo, Alketa Qafmolla, Vito Antonio Malagnino
Abstract:
Background: Dental caries is the most common dental disease and pregnancy represents a special process of physical, hormonal and metabolic changes in pregnant women, which is accompanied by an imbalance in the oral cavity. Objective: The objective of this study is to evaluate caries reduction after dental visits, the scaling of teeth, fluoridated water, brushing of the teeth and using fluoride toothpaste before and during pregnancy. Materials and methods: This study was conducted in the time period March 2018- September 2021, the age range of the participants was: 18-41 years old. The sample taken under observation was composed of 84 pregnant women. The questionnaire included the demographic characteristics of the sample, such as age, women's education level was primary, secondary, and higher education. Based on women's education level, our analysis found that 25.9% of pregnant women had completed primary education, 35.2% of them had secondary education and 38.9% of pregnant women had higher education. The descriptive and analytical research analysis is formulated as a longitudinal study. Statistical analysis was performed using IBM SPSS Statistics 23.0. The significance level (α) was set at 0.05, whereas P-value and analysis of variance (ANOVA) were used to analyze the data. Results: In the present study, it was observed that there is a strong relationship between dental visits and the scaling of the teeth with the value of P˂ .0001. While the number of teeth with caries before pregnancy and fluoridated water have a P-value=0.002. If we compare the same factor with the number of teeth with dental caries during pregnancy, the correlation is P-value = 0.0001. The number of teeth with caries before pregnancy and carbohydrates consumption has a strong relation with P-value=0.05. According to the present research, the number of teeth with dental caries before pregnancy in relation to brushing the teeth has a P-value ˂ 0.05. Furthermore, in the actual research, it was established that using fluoride toothpaste doesn’t affect the number of teeth with caries before pregnancy with a P-value= .314. Conclusion: According to the results of the present study performed in Albania, it was found out that the periodical dental visits, scaling of the teeth, fluoridated water, brushing of the teeth influenced caries reduction before and during pregnancy. In comparison, the usage of fluoride toothpaste did not have any effect on dental caries reduction in the same time period. The recommendations are as follows: maintaining oral hygiene, using fluoridated water and brushing the teeth regularly. Healthcare providers should inform pregnant women about the importance of oral health and the implementation of measures to manage dental caries.Keywords: brushing of the teeth, dental visits, dental scaling, fluoridated water, pregnancy
Procedia PDF Downloads 19460 The Structure and Development of a Wing Tip Vortex under the Effect of Synthetic Jet Actuation
Authors: Marouen Dghim, Mohsen Ferchichi
Abstract:
The effect of synthetic jet actuation on the roll-up and the development of a wing tip vortex downstream a square-tipped rectangular wing was investigated experimentally using hotwire anemometry. The wing is equipped with a hallow cavity designed to generate a high aspect ratio synthetic jets blowing at an angles with respect to the spanwise direction. The structure of the wing tip vortex under the effect of fluidic actuation was examined at a chord Reynolds number Re_c=8×10^4. An extensive qualitative study on the effect of actuation on the spanwise pressure distribution at c⁄4 was achieved using pressure scanner measurements in order to determine the optimal actuation parameters namely, the blowing momentum coefficient, Cμ, and the non-dimensionalized actuation frequency, F^+. A qualitative study on the effect of actuation parameters on the spanwise pressure distribution showed that optimal actuation frequencies of the synthetic jet were found within the range amplified by both long and short wave instabilities where spanwise pressure coefficients exhibited a considerable decrease by up to 60%. The vortex appeared larger and more diffuse than that of the natural vortex case. Operating the synthetic jet seemed to introduce unsteadiness and turbulence into the vortex core. Based on the ‘a priori’ optimal selected parameters, results of the hotwire wake survey indicated that the actuation achieved a reduction and broadening of the axial velocity deficit. A decrease in the peak tangential velocity associated with an increase in the vortex core radius was reported as a result of the accelerated radial transport of angular momentum. Peak vorticity level near the core was also found to be largely diffused as a direct result of the increased turbulent mixing within the vortex. The wing tip vortex a exhibited a reduced strength and a diffused core as a direct result of increased turbulent mixing due to the presence of turbulent small scale vortices within its core. It is believed that the increased turbulence within the vortex due to the synthetic jet control was the main mechanism associated with the decreased strength and increased size of the wing tip vortex as it evolves downstream. A comparison with a ‘non-optimal’ case was included to demonstrate the effectiveness of selecting the appropriate control parameters. The Synthetic Jet will be operated at various actuation configurations and an extensive parametric study is projected to determine the optimal actuation parameters.Keywords: flow control, hotwire anemometry, synthetic jet, wing tip vortex
Procedia PDF Downloads 43659 The Toxicity of Doxorubicin Connected with Nanotransporters
Authors: Iva Blazkova, Amitava Moulick, Vedran Milosavljevic, Pavel Kopel, Marketa Vaculovicova, Vojtech Adam, Rene Kizek
Abstract:
Doxorubicin is one of the most commonly used and the most effective chemotherapeutic drugs. This antracycline drug isolated from the bacteria Streptomyces peuceticus var. caesius is sold under the trade name Adriamycin (hydroxydaunomycin, hydroxydaunorubicin). Doxorubicin is used in single therapy to treat hematological malignancies (blood cancers, leukaemia, lymphoma), many types of carcinoma (solid tumors) and soft tissue sarcomas. It has many serious side effects like nausea and vomiting, hair lost, myelosupression, oral mucositis, skin reactions and redness, but the most serious one is the cardiotoxicity. Because of the risk of heart attack and congestive heart failure, the total dose administered to patients has to be accurately monitored. With the aim to lower the side effects and to targeted delivery of doxorubicin into the tumor tissue, the different nanoparticles are studied. The drug can be bound on a surface of nanoparticle, encapsulated in the inner cavity, or incorporated into the structure of nanoparticle. Among others, carbon nanoparticles (graphene, carbon nanotubes, fullerenes) are highly studied. Besides the number of inorganic nanoparticles, a great potential exhibit also organic ones mainly lipid-based and polymeric nanoparticle. The aim of this work was to perform a toxicity study of free doxorubicin compared to doxorubicin conjugated with various nanotransporters. The effect of liposomes, fullerenes, graphene, and carbon nanotubes on the toxicity was analyzed. As a first step, the binding efficacy of between doxorubicin and the nanotransporter was determined. The highest efficacy was detected in case of liposomes (85% of applied drug was encapsulated) followed by graphene, carbon nanotubes and fullerenes. For the toxicological studies, the chicken embryos incubated under controlled conditions (37.5 °C, 45% rH, rotation every 2 hours) were used. In 7th developmental day of chicken embryos doxorubicin or doxorubicin-nanotransporter complex was applied on the chorioallantoic membrane of the eggs and the viability was analyzed every day till the 17th developmental day. Then the embryos were extracted from the shell and the distribution of doxorubicin in the body was analyzed by measurement of organs extracts using laser induce fluorescence detection. The chicken embryo mortality caused by free doxorubicin (30%) was significantly lowered by using the conjugation with nanomaterials. The highest accumulation of doxorubicin and doxorubicin nanotransporter complexes was observed in the liver tissueKeywords: doxorubicin, chicken embryos, nanotransporters, toxicity
Procedia PDF Downloads 44958 Processes and Application of Casting Simulation and Its Software’s
Authors: Surinder Pal, Ajay Gupta, Johny Khajuria
Abstract:
Casting simulation helps visualize mold filling and casting solidification; predict related defects like cold shut, shrinkage porosity and hard spots; and optimize the casting design to achieve the desired quality with high yield. Flow and solidification of molten metals are, however, a very complex phenomenon that is difficult to simulate correctly by conventional computational techniques, especially when the part geometry is intricate and the required inputs (like thermo-physical properties and heat transfer coefficients) are not available. Simulation software is based on the process of modeling a real phenomenon with a set of mathematical formulas. It is, essentially, a program that allows the user to observe an operation through simulation without actually performing that operation. Simulation software is used widely to design equipment so that the final product will be as close to design specs as possible without expensive in process modification. Simulation software with real-time response is often used in gaming, but it also has important industrial applications. When the penalty for improper operation is costly, such as airplane pilots, nuclear power plant operators, or chemical plant operators, a mockup of the actual control panel is connected to a real-time simulation of the physical response, giving valuable training experience without fear of a disastrous outcome. The all casting simulation software has own requirements, like magma cast has only best for crack simulation. The latest generation software Auto CAST developed at IIT Bombay provides a host of functions to support method engineers, including part thickness visualization, core design, multi-cavity mold design with common gating and feeding, application of various feed aids (feeder sleeves, chills, padding, etc.), simulation of mold filling and casting solidification, automatic optimization of feeders and gating driven by the desired quality level, and what-if cost analysis. IIT Bombay has developed a set of applications for the foundry industry to improve casting yield and quality. Casting simulation is a fast and efficient solution for process for advanced tool which is the result of more than 20 years of collaboration with major industrial partners and academic institutions around the world. In this paper the process of casting simulation is studied.Keywords: casting simulation software’s, simulation technique’s, casting simulation, processes
Procedia PDF Downloads 47557 Computational Modelling of pH-Responsive Nanovalves in Controlled-Release System
Authors: Tomilola J. Ajayi
Abstract:
A category of nanovalves system containing the α-cyclodextrin (α-CD) ring on a stalk tethered to the pores of mesoporous silica nanoparticles (MSN) is theoretically and computationally modelled. This functions to control opening and blocking of the MSN pores for efficient targeted drug release system. Modeling of the nanovalves is based on the interaction between α-CD and the stalk (p-anisidine) in relation to pH variation. Conformational analysis was carried out prior to the formation of the inclusion complex, to find the global minimum of both neutral and protonated stalk. B3LYP/6-311G**(d, p) basis set was employed to attain all theoretically possible conformers of the stalk. Six conformers were taken into considerations, and the dihedral angle (θ) around the reference atom (N17) of the p-anisidine stalk was scanned from 0° to 360° at 5° intervals. The most stable conformer was obtained at a dihedral angle of 85.3° and was fully optimized at B3LYP/6-311G**(d, p) level of theory. The most stable conformer obtained from conformational analysis was used as the starting structure to create the inclusion complexes. 9 complexes were formed by moving the neutral guest into the α-CD cavity along the Z-axis in 1 Å stepwise while keeping the distance between dummy atom and OMe oxygen atom on the stalk restricted. The dummy atom and the carbon atoms on α-CD structure were equally restricted for orientation A (see Scheme 1). The generated structures at each step were optimized with B3LYP/6-311G**(d, p) methods to determine their energy minima. Protonation of the nitrogen atom on the stalk occurs at acidic pH, leading to unsatisfactory host-guest interaction in the nanogate; hence there is dethreading. High required interaction energy and conformational change are theoretically established to drive the release of α-CD at a certain pH. The release was found to occur between pH 5-7 which agreed with reported experimental results. In this study, we applied the theoretical model for the prediction of the experimentally observed pH-responsive nanovalves which enables blocking, and opening of mesoporous silica nanoparticles pores for targeted drug release system. Our results show that two major factors are responsible for the cargo release at acidic pH. The higher interaction energy needed for the complex/nanovalve formation to exist after protonation as well as conformational change upon protonation are driving the release due to slight pH change from 5 to 7.Keywords: nanovalves, nanogate, mesoporous silica nanoparticles, cargo
Procedia PDF Downloads 12356 Particle Gradient Generation in a Microchannel Using a Single IDT
Authors: Florian Kiebert, Hagen Schmidt
Abstract:
Standing surface acoustic waves (sSAWs) have already been used to manipulate particles in a microfluidic channel made of polydimethylsiloxan (PDMS). Usually two identical facing interdigital transducers (IDTs) are exploited to form an sSAW. Further, it has been reported that an sSAW can be generated by a single IDT using a superstrate resonating cavity or a PDMS post. Nevertheless, both setups utilising a traveling surface acoustic wave (tSAW) to create an sSAW for particle manipulation are costly. We present a simplified setup with a tSAW and a PDMS channel to form an sSAW. The incident tSAW is reflected at the rear PDMS channel wall and superimposed with the reflected tSAW. This superpositioned waves generates an sSAW but only at regions where the distance to the rear channel wall is smaller as the attenuation length of the tSAW minus the channel width. Therefore in a channel of 500µm width a tSAW with a wavelength λ = 120 µm causes a sSAW over the whole channel, whereas a tSAW with λ = 60 µm only forms an sSAW next to the rear wall of the channel, taken into account the attenuation length of a tSAW in water. Hence, it is possible to concentrate and trap particles in a defined region of the channel by adjusting the relation between the channel width and tSAW wavelength. Moreover, it is possible to generate a particle gradient over the channel width by picking the right ratio between channel wall and wavelength. The particles are moved towards the rear wall by the acoustic streaming force (ASF) and the acoustic radiation force (ARF) caused by the tSAW generated bulk acoustic wave (BAW). At regions in the channel were the sSAW is dominating the ARF focuses the particles in the pressure nodes formed by the sSAW caused BAW. On the one side the ARF generated by the sSAW traps the particle at the center of the tSAW beam, i. e. of the IDT aperture. On the other side, the ASF leads to two vortices, one on the left and on the right side of the focus region, deflecting the particles out of it. Through variation of the applied power it is possible to vary the number of particles trapped in the focus points, because near to the rear wall the amplitude of the reflected tSAW is higher and, therefore, the ARF of the sSAW is stronger. So in the vicinity of the rear wall the concentration of particles is higher but decreases with increasing distance to the wall, forming a gradient of particles. The particle gradient depends on the applied power as well as on the flow rate. Thus by variation of these two parameters it is possible to change the particle gradient. Furthermore, we show that the particle gradient can be modified by changing the relation between the channel width and tSAW wavelength. Concluding a single IDT generates an sSAW in a PDMS microchannel enables particle gradient generation in a well-defined microfluidic flow system utilising the ARF and ASF of a tSAW and an sSAW.Keywords: ARF, ASF, particle manipulation, sSAW, tSAW
Procedia PDF Downloads 33555 Isotope Effects on Inhibitors Binding to HIV Reverse Transcriptase
Authors: Agnieszka Krzemińska, Katarzyna Świderek, Vicente Molinier, Piotr Paneth
Abstract:
In order to understand in details the interactions between ligands and the enzyme isotope effects were studied between clinically used drugs that bind in the active site of Human Immunodeficiency Virus Reverse Transcriptase, HIV-1 RT, as well as triazole-based inhibitor that binds in the allosteric pocket of this enzyme. The magnitudes and origins of the resulting binding isotope effects were analyzed. Subsequently, binding isotope effect of the same triazole-based inhibitor bound in the active site were analyzed and compared. Together, these results show differences in binding origins in two sites of the enzyme and allow to analyze binding mode and place of newly synthesized inhibitors. Typical protocol is described below on the example of triazole ligand in the allosteric pocket. Triazole was docked into allosteric cavity of HIV-1 RT with Glide using extra-precision mode as implemented in Schroedinger software. The structure of HIV-1 RT was obtained from Protein Data Bank as structure of PDB ID 2RKI. The pKa for titratable amino acids was calculated using PROPKA software, and in order to neutralize the system 15 Cl- were added using tLEaP package implemented in AMBERTools ver.1.5. Also N-terminals and C-terminals were build using tLEaP. The system was placed in 144x160x144Å3 orthorhombic box of water molecules using NAMD program. Missing parameters for triazole were obtained at the AM1 level using Antechamber software implemented in AMBERTools. The energy minimizations were carried out by means of a conjugate gradient algorithm using NAMD. Then system was heated from 0 to 300 K with temperature increment 0.001 K. Subsequently 2 ns Langevin−Verlet (NVT) MM MD simulation with AMBER force field implemented in NAMD was carried out. Periodic Boundary Conditions and cut-offs for the nonbonding interactions, range radius from 14.5 to 16 Å, are used. After 2 ns relaxation 200 ps of QM/MM MD at 300 K were simulated. The triazole was treated quantum mechanically at the AM1 level, protein was described using AMBER and water molecules were described using TIP3P, as implemented in fDynamo library. Molecules 20 Å apart from the triazole were kept frozen, with cut-offs established on range radius from 14.5 to 16 Å. In order to describe interactions between triazole and RT free energy of binding using Free Energy Perturbation method was done. The change in frequencies from ligand in solution to ligand bounded in enzyme was used to calculate binding isotope effects.Keywords: binding isotope effects, molecular dynamics, HIV, reverse transcriptase
Procedia PDF Downloads 43154 Clean Sky 2 – Project PALACE: Aeration’s Experimental Sound Velocity Investigations for High-Speed Gerotor Simulations
Authors: Benoît Mary, Thibaut Gras, Gaëtan Fagot, Yvon Goth, Ilyes Mnassri-Cetim
Abstract:
A Gerotor pump is composed of an external and internal gear with conjugate cycloidal profiles. From suction to delivery ports, the fluid is transported inside cavities formed by teeth and driven by the shaft. From a geometric and conceptional side it is worth to note that the internal gear has one tooth less than the external one. Simcenter Amesim v.16 includes a new submodel for modelling the hydraulic Gerotor pumps behavior (THCDGP0). This submodel considers leakages between teeth tips using Poiseuille and Couette flows contributions. From the 3D CAD model of the studied pump, the “CAD import” tool takes out the main geometrical characteristics and the submodel THCDGP0 computes the evolution of each cavity volume and their relative position according to the suction or delivery areas. This module, based on international publications, presents robust results up to 6 000 rpm for pressure greater than atmospheric level. For higher rotational speeds or lower pressures, oil aeration and cavitation effects are significant and highly drop the pump’s performance. The liquid used in hydraulic systems always contains some gas, which is dissolved in the liquid at high pressure and tends to be released in a free form (i.e. undissolved as bubbles) when pressure drops. In addition to gas release and dissolution, the liquid itself may vaporize due to cavitation. To model the relative density of the equivalent fluid, modified Henry’s law is applied in Simcenter Amesim v.16 to predict the fraction of undissolved gas or vapor. Three parietal pressure sensors have been set up upstream from the pump to estimate the sound speed in the oil. Analytical models have been compared with the experimental sound speed to estimate the occluded gas content. Simcenter Amesim v.16 model was supplied by these previous analyses marks which have successfully improved the simulations results up to 14 000 rpm. This work provides a sound foundation for designing the next Gerotor pump generation reaching high rotation range more than 25 000 rpm. This improved module results will be compared to tests on this new pump demonstrator.Keywords: gerotor pump, high speed, numerical simulations, aeronautic, aeration, cavitation
Procedia PDF Downloads 13353 Effects of Bleaching Procedures on Dentine Sensitivity
Authors: Suhayla Reda Al-Banai
Abstract:
Problem Statement: Tooth whitening was used for over one hundred and fifty year. The question concerning the whiteness of teeth is a complex one since tooth whiteness will vary from individual to individual, dependent on age and culture, etc. Tooth whitening following treatment may be dependent on the type of whitening system used to whiten the teeth. There are a few side-effects to the process, and these include tooth sensitivity and gingival irritation. Some individuals may experience no pain or sensitivity following the procedure. Purpose: To systematically review the available published literature until 31st December 2021 to identify all relevant studies for inclusion and to determine whether there was any evidence demonstrating that the application of whitening procedures resulted in the tooth sensitivity. Aim: Systematically review the available published works of literature to identify all relevant studies for inclusion and to determine any evidence demonstrating that application of 10% & 15% carbamide peroxide in tooth whitening procedures resulted in tooth sensitivity. Material and Methods: Following a review of 70 relevant papers from searching both electronic databases (OVID MEDLINE and PUBMED) and hand searching of relevant written journals, 49 studies were identified, 42 papers were subsequently excluded, and 7 studies were finally accepted for inclusion. The extraction of data for inclusion was conducted by two reviewers. The main outcome measures were the methodology and assessment used by investigators to evaluate tooth sensitivity in tooth whitening studies. Results: The reported evaluation of tooth sensitivity during tooth whitening procedures was based on the subjective response of subjects rather than a recognized methodology for evaluating. One of the problems in evaluating was the lack of homogeneity in study design. Seven studies were included. The studies included essential features namely: randomized group, placebo controls, doubleblind and single-blind. Drop-out was obtained from two of included studies. Three of the included studies reported sensitivity at the baseline visit. Two of the included studies mentioned the exclusion criteria Conclusions: The results were inconclusive due to: Limited number of included studies, the study methodology, and evaluation of DS reported. Tooth whitening procedures adversely affect both hard and soft tissues in the oral cavity. Sideeffects are mild and transient in nature. Whitening solutions with greater than 10% carbamide peroxide causes more tooth sensitivity. Studies using nightguard vital bleaching with 10% carbamide peroxide reported two side effects tooth sensitivity and gingival irritation, although tooth sensitivity was more prevalent than gingival irritationKeywords: dentine, sensitivity, bleaching, carbamide peroxde
Procedia PDF Downloads 7052 Part Variation Simulations: An Industrial Case Study with an Experimental Validation
Authors: Narendra Akhadkar, Silvestre Cano, Christophe Gourru
Abstract:
Injection-molded parts are widely used in power system protection products. One of the biggest challenges in an injection molding process is shrinkage and warpage of the molded parts. All these geometrical variations may have an adverse effect on the quality of the product, functionality, cost, and time-to-market. The situation becomes more challenging in the case of intricate shapes and in mass production using multi-cavity tools. To control the effects of shrinkage and warpage, it is very important to correctly find out the input parameters that could affect the product performance. With the advances in the computer-aided engineering (CAE), different tools are available to simulate the injection molding process. For our case study, we used the MoldFlow insight tool. Our aim is to predict the spread of the functional dimensions and geometrical variations on the part due to variations in the input parameters such as material viscosity, packing pressure, mold temperature, melt temperature, and injection speed. The input parameters may vary during batch production or due to variations in the machine process settings. To perform the accurate product assembly variation simulation, the first step is to perform an individual part variation simulation to render realistic tolerance ranges. In this article, we present a method to simulate part variations coming from the input parameters variation during batch production. The method is based on computer simulations and experimental validation using the full factorial design of experiments (DoE). The robustness of the simulation model is verified through input parameter wise sensitivity analysis study performed using simulations and experiments; all the results show a very good correlation in the material flow direction. There exists a non-linear interaction between material and the input process variables. It is observed that the parameters such as packing pressure, material, and mold temperature play an important role in spread on functional dimensions and geometrical variations. This method will allow us in the future to develop accurate/realistic virtual prototypes based on trusted simulated process variation and, therefore, increase the product quality and potentially decrease the time to market.Keywords: correlation, molding process, tolerance, sensitivity analysis, variation simulation
Procedia PDF Downloads 17851 Achieving Product Robustness through Variation Simulation: An Industrial Case Study
Authors: Narendra Akhadkar, Philippe Delcambre
Abstract:
In power protection and control products, assembly process variations due to the individual parts manufactured from single or multi-cavity tooling is a major problem. The dimensional and geometrical variations on the individual parts, in the form of manufacturing tolerances and assembly tolerances, are sources of clearance in the kinematic joints, polarization effect in the joints, and tolerance stack-up. All these variations adversely affect the quality of product, functionality, cost, and time-to-market. Variation simulation analysis may be used in the early product design stage to predict such uncertainties. Usually, variations exist in both manufacturing processes and materials. In the tolerance analysis, the effect of the dimensional and geometrical variations of the individual parts on the functional characteristics (conditions) of the final assembled products are studied. A functional characteristic of the product may be affected by a set of interrelated dimensions (functional parameters) that usually form a geometrical closure in a 3D chain. In power protection and control products, the prerequisite is: when a fault occurs in the electrical network, the product must respond quickly to react and break the circuit to clear the fault. Usually, the response time is in milliseconds. Any failure in clearing the fault may result in severe damage to the equipment or network, and human safety is at stake. In this article, we have investigated two important functional characteristics that are associated with the robust performance of the product. It is demonstrated that the experimental data obtained at the Schneider Electric Laboratory prove the very good prediction capabilities of the variation simulation performed using CETOL (tolerance analysis software) in an industrial context. Especially, this study allows design engineers to better understand the critical parts in the product that needs to be manufactured with good, capable tolerances. On the contrary, some parts are not critical for the functional characteristics (conditions) of the product and may lead to some reduction of the manufacturing cost, ensuring robust performance. The capable tolerancing is one of the most important aspects in product and manufacturing process design. In the case of miniature circuit breaker (MCB), the product's quality and its robustness are mainly impacted by two aspects: (1) allocation of design tolerances between the components of a mechanical assembly and (2) manufacturing tolerances in the intermediate machining steps of component fabrication.Keywords: geometrical variation, product robustness, tolerance analysis, variation simulation
Procedia PDF Downloads 16450 A (Morpho) Phonological Typology of Demonstratives: A Case Study in Sound Symbolism
Authors: Seppo Kittilä, Sonja Dahlgren
Abstract:
In this paper, a (morpho)phonological typology of proximal and distal demonstratives is proposed. Only the most basic proximal (‘this’) and distal (‘that’) forms have been considered, potential more fine-grained distinctions based on proximity are not relevant to our discussion, nor are the other functions the discussed demonstratives may have. The sample comprises 82 languages that represent the linguistic diversity of the world’s languages, although the study is not based on a systematic sample. Four different major types are distinguished; (1) Vowel type: front vs. back; high vs. low vowel (2) Consonant type: front-back consonants (3) Additional element –type (4) Varia. The proposed types can further be subdivided according to whether the attested difference concern only, e.g., vowels, or whether there are also other changes. For example, the first type comprises both languages such as Betta Kurumba, where only the vowel changes (i ‘this’, a ‘that’) and languages like Alyawarra (nhinha vs. nhaka), where there are also other changes. In the second type, demonstratives are distinguished based on whether the consonants are front or back; typically front consonants (e.g., labial and dental) appear on proximal demonstratives and back consonants on distal demonstratives (such as velar or uvular consonants). An example is provided by Bunaq, where bari marks ‘this’ and baqi ‘that’. In the third type, distal demonstratives typically have an additional element, making it longer in form than the proximal one (e.g., Òko òne ‘this’, ònébé ‘that’), but the type also comprises languages where the distal demonstrative is simply phonologically longer (e.g., Ngalakan nu-gaʔye vs. nu-gunʔbiri). Finally, the last type comprises cases that do not fit into the three other types, but a number of strategies are used by the languages of this group. The two first types can be explained by iconicity; front or high phonemes appear on the proximal demonstratives, while back/low phonemes are related to distal demonstratives. This means that proximal demonstratives are pronounced at the front and/or high part of the oral cavity, while distal demonstratives are pronounced lower and more back, which reflects the proximal/distal nature of their referents in the physical world. The first type is clearly the most common in our data (40/82 languages), which suggests a clear association with iconicity. Our findings support earlier findings that proximal and distal demonstratives have an iconic phonemic manifestation. For example, it has been argued that /i/ is related to smallness (small distance). Consonants, however, have not been considered before, or no systematic correspondences have been discovered. The third type, in turn, can be explained by markedness; the distal element is more marked than the proximal demonstrative. Moreover, iconicity is relevant also here: some languages clearly use less linguistic substance for referring to entities close to the speaker, which is manifested in the longer (morpho)phonological form of the distal demonstratives. The fourth type contains different kinds of cases, and systematic generalizations are hard to make.Keywords: demonstratives, iconicity, language typology, phonology
Procedia PDF Downloads 15349 Nondestructive Inspection of Reagents under High Attenuated Cardboard Box Using Injection-Seeded THz-Wave Parametric Generator
Authors: Shin Yoneda, Mikiya Kato, Kosuke Murate, Kodo Kawase
Abstract:
In recent years, there have been numerous attempts to smuggle narcotic drugs and chemicals by concealing them in international mail. Combatting this requires a non-destructive technique that can identify such illicit substances in mail. Terahertz (THz) waves can pass through a wide variety of materials, and many chemicals show specific frequency-dependent absorption, known as a spectral fingerprint, in the THz range. Therefore, it is reasonable to investigate non-destructive mail inspection techniques that use THz waves. For this reason, in this work, we tried to identify reagents under high attenuation shielding materials using injection-seeded THz-wave parametric generator (is-TPG). Our THz spectroscopic imaging system using is-TPG consisted of two non-linear crystals for emission and detection of THz waves. A micro-chip Nd:YAG laser and a continuous wave tunable external cavity diode laser were used as the pump and seed source, respectively. The pump beam and seed beam were injected to the LiNbO₃ crystal satisfying the noncollinear phase matching condition in order to generate high power THz-wave. The emitted THz wave was irradiated to the sample which was raster scanned by the x-z stage while changing the frequencies, and we obtained multispectral images. Then the transmitted THz wave was focused onto another crystal for detection and up-converted to the near infrared detection beam based on nonlinear optical parametric effects, wherein the detection beam intensity was measured using an infrared pyroelectric detector. It was difficult to identify reagents in a cardboard box because of high noise levels. In this work, we introduce improvements for noise reduction and image clarification, and the intensity of the near infrared detection beam was converted correctly to the intensity of the THz wave. A Gaussian spatial filter is also introduced for a clearer THz image. Through these improvements, we succeeded in identification of reagents hidden in a 42-mm thick cardboard box filled with several obstacles, which attenuate 56 dB at 1.3 THz, by improving analysis methods. Using this system, THz spectroscopic imaging was possible for saccharides and may also be applied to cases where illicit drugs are hidden in the box, and multiple reagents are mixed together. Moreover, THz spectroscopic imaging can be achieved through even thicker obstacles by introducing an NIR detector with higher sensitivity.Keywords: nondestructive inspection, principal component analysis, terahertz parametric source, THz spectroscopic imaging
Procedia PDF Downloads 17748 Congenital Diaphragmatic Hernia Outcomes in a Low-Volume Center
Authors: Michael Vieth, Aric Schadler, Hubert Ballard, J. A. Bauer, Pratibha Thakkar
Abstract:
Introduction: Congenital diaphragmatic hernia (CDH) is a condition characterized by the herniation of abdominal contents into the thoracic cavity requiring postnatal surgical repair. Previous literature suggests improved CDH outcomes at high-volume regional referral centers compared to low-volume centers. The purpose of this study was to examine CDH outcomes at Kentucky Children’s Hospital (KCH), a low-volume center, compared to the Congenital Diaphragmatic Hernia Study Group (CDHSG). Methods: A retrospective chart review was performed at KCH from 2007-2019 for neonates with CDH, and then subdivided into two cohorts: those requiring ECMO therapy and those not requiring ECMO therapy. Basic demographic data and measures of mortality and morbidity including ventilator days and length of stay were compared to the CDHSG. Measures of morbidity for the ECMO cohort including duration of ECMO, clinical bleeding, intracranial hemorrhage, sepsis, need for continuous renal replacement therapy (CRRT), need for sildenafil at discharge, timing of surgical repair, and total ventilator days were collected. Statistical analysis was performed using IBM SPSS Statistics version 28. One-sample t-tests and one-sample Wilcoxon Signed Rank test were utilized as appropriate.Results: There were a total of 27 neonatal patients with CDH at KCH from 2007-2019; 9 of the 27 required ECMO therapy. The birth weight and gestational age were similar between KCH and the CDHSG (2.99 kg vs 2.92 kg, p =0.655; 37.0 weeks vs 37.4 weeks, p =0.51). About half of the patients were inborn in both cohorts (52% vs 56%, p =0.676). KCH cohort had significantly more Caucasian patients (96% vs 55%, p=<0.001). Unadjusted mortality was similar in both groups (KCH 70% vs CDHSG 72%, p =0.857). Using ECMO utilization (KCH 78% vs CDHSG 52%, p =0.118) and need for surgical repair (KCH 95% vs CDHSG 85%, p =0.060) as proxy for severity, both groups’ mortality were comparable. No significant difference was noted for pulmonary outcomes such as average ventilator days (KCH 43.2 vs. CDHSG 17.3, p =0.078) and home oxygen dependency (KCH 44% vs. CDHSG 24%, p =0.108). Average length of hospital stay for patients treated at KCH was similar to CDHSG (64.4 vs 49.2, p=1.000). Conclusion: Our study demonstrates that outcome in CDH patients is independent of center’s case volume status. Management of CDH with a standardized approach in a low-volume center can yield similar outcomes. This data supports the treatment of patients with CDH at low-volume centers as opposed to transferring to higher-volume centers.Keywords: ECMO, case volume, congenital diaphragmatic hernia, congenital diaphragmatic hernia study group, neonate
Procedia PDF Downloads 9647 Successful Excision of Lower Lip Mucocele Using 2780 nm Er,Cr:YSGG Laser
Authors: Lubna M. Al-Otaibi
Abstract:
Mucocele is a common benign neoplasm of the oral cavity and the most common after fibroma. The lesion develops as a result of retention or extravasation of mucous material from minor salivary glands. Extravasation type of mucocele results from trauma and mostly occurs in the lower lip of young patients. The various treatment options available for the treatment of mucocele are associated with a relatively high incidence of recurrence making surgical intervention necessary for a permanent cure. The conventional surgical procedure, however, arouses apprehension in the patient and is associated with bleeding and postoperative pain. Recently, treatment of mucocele with lasers has become a viable treatment option. Various types of lasers are being used and are preferable over the conventional surgical procedure as they provide good hemostasis, reduced postoperative swelling and pain, reduced bacterial population, lesser need for suturing, faster healing and low recurrence rates. Er,Cr:YSGG is a solid-state laser with great affinity to water molecule. Its hydrokinetic cutting action allows it to work effectively on hydrated tissues without any thermal damage. However, up to date, only a few studies have reported its use in the removal of lip mucocele, especially in children. In this case, a 6 year old female patient with history of trauma to the lower lip presented with a soft, sessile, whitish-bluish 4 mm papule. The lesion was present for approximately four months and was fluctuant in size. The child developed a habit of biting the lesion causing injury, bleeding and discomfort. Surgical excision under local anaesthesia was performed using 2780 nm Er,Cr:YSGG Laser (WaterLase iPlus, Irvine, CA) with a Gold handpiece and MZ6 tip (3.5w, 50 Hz, 20% H2O, 20% Air, S mode). The tip was first applied in contact mode with focused beam using the Circumferential Incision Technique (CIT) to excise the tissue followed by the removal of the underlying causative minor salivary gland. Bleeding was stopped using Laser Dry Bandage setting (0.5w, 50 Hz, 1% H2O, 20% Air, S mode) and no suturing was needed. Safety goggles were worn and high-speed suction was used for smoke evacuation. Mucocele excision using 2780 nm Er,Cr:YSGG laser was rapid, easy to perform with excellent precision and allowed for histopathological examination of the excised tissue. The patient was comfortable and there were minimum bleeding and no sutures, postoperative pain, scarring or recurrence. Laser assisted mucocele excision appears to have efficient and reliable benefits in young patients and should be considered as an alternative to conventional surgical and non-surgical techniques.Keywords: Erbium, excision, laser, lip, mucocele
Procedia PDF Downloads 23646 Non-Melanoma Skin Cancer of Cephalic Extremity – Clinical and Histological Aspects
Authors: Razvan Mercut, Mihaela Ionescu, Vlad Parvanescu, Razvan Ghita, Tudor-Gabriel Caragea, Cristina Simionescu, Marius-Eugen Ciurea
Abstract:
Introduction: Over the past years, the incidence of non-melanoma skin cancer (NMSC) has continuously increased, being one of the most commonly diagnosed carcinomasofthe cephalic extremity. NMSC regroups basal cell carcinoma (BCC), squamous cell carcinoma (SCC), Merkel cell carcinoma, cutaneous lymphoma, and sarcoma. The most common forms are BCC and SCC, both still implying a significant level of morbidity due to local invasion (especially BCC), even if the overall death rates are declining. The objective of our study was the evaluation of clinical and histological aspects of NMSC for a group of patients with BCC and SCC, from Craiova, a south-western major city in Romania. Materialand method: Our study lot comprised 65 patients, with an almost equal distribution of sexes, and ages between 23-91 years old (mean value±standard deviation62.61±16.67), all treated within the Clinic of Plastic Surgery and Reconstructive Microsurgery, Clinical Emergency County Hospital Craiova, Romania, between 2019-2020. In order to determine the main morphological characteristics of both studied cancers, we used paraffin embedding techniques, with various staining methods:hematoxylin-eosin, Masson's trichrome stain with aniline blue, and Periodic acid-schiffAlcian Blue. The statistical study was completed using Microsoft Excel (Microsoft Corp., Redmond, WA, USA), with XLSTAT (Addinsoft SARL, Paris, France). Results: The overall results of our study indicate that BCC accounts for 67.69% of all NMSC forms; SCC covers 27.69%, while 4.62% are representedby other forms. The most frequent site is the nose for BCC (27.69%, 18 patients), being followed by preauricular regions, forehead, and periorbital areas. For patients with SCC, tumors were mainly located at lips level (66.67%, 12 patients). The analysis of NMSC histological forms indicated that nodular BCC is predominant (45.45%, 20 patients), as well as ulcero-vegetant SCC (38.89%, 7 patients). We have not identified any topographic characteristics or NMSC forms significantly related to age or sex. Conclusions: The most frequent NMSC form identified for our study lot was BCC. The preferred location was the nose for BCC. For SCC, the oral cavity is the most frequent anatomical site, especially the lips level. Nodular BCC and ulcero-vegetant SCC were the most commonly identified histological types. Our findings emphasize the need for periodic screening, in order to improve prevention and early treatment for these malignancies.Keywords: non-melanoma skin cancer, basal cell carcinoma, squamous cell carcinoma, histological
Procedia PDF Downloads 18945 Occult Haemolacria Paradigm in the Study of Tears
Authors: Yuliya Huseva
Abstract:
To investigate the contents of tears to determine latent blood. Methods: Tear samples from 72 women were studied with the microscopy of tears aspirated with a capillary and stained by Nocht and with a chemical method of test strips with chromogen. Statistical data processing was carried out using statistical packages Statistica 10.0 for Windows, calculation of Pearson's chi-square test, Yule association coefficient, the method of determining sensitivity and specificity. Results:, In 30.6% (22) of tear samples erythrocytes were revealed microscopically. Correlations between the presence of erythrocytes in the tear and the phase of the menstrual cycle has been discovered. In the follicular phase of the cycle, erythrocytes were found in 59.1% (13) people, which is significantly more (x2=4.2, p=0.041) compared to the luteal phase - in 40.9% (9) women. In the first seven days of the follicular phase of the menstrual cycle the erythrocytes were predominanted of in the tears of women examined testifies in favour of the vicarious bleeding from the mucous membranes of extragenital organs in sync with menstruation. Of the other cellular elements in tear samples with latent haemolacria, neutrophils prevailed - in 45.5% (10), while lymphocytes were less common - in 27.3% (6), because neutrophil exudation is accompanied by vasodilatation of the conjunctiva and the release of erythrocytes into the conjunctival cavity. It was found that the prognostic significance of the chemical method was 0.53 of the microscopic method. In contrast to microscopy, which detected blood in tear samples from 30.6% (22) of women, blood was detected chemically in tears of 16.7% (12). An association between latent haemolacria and endometriosis was found (k=0.75, p≤0.05). Microscopically, in the tears of patients with endometriosis, erythrocytes were detected in 70% of cases, while in healthy women without endometriosis - in 25% of cases. The proportion of women with erythrocytes in tears, determined by a chemical method, was 41.7% among patients with endometriosis, which is significantly more (x2=6.5, p=0.011) than 11.7% among women without endometriosis. The data obtained can be explained by the etiopathogenesis of the extragenital endometriosis which is caused by hematogenous spread of endometrial tissue into the orbit. In endometriosis, erythrocytes are found against the background of accumulations of epithelial cells. In the tear samples of 4 women with endometriosis, glandular cuboidal epithelial cells, morphologically similar to endometrial cells, were found, which may indicate a generalization of the disease. Conclusions: Single erythrocytes can normally be found in the tears, their number depends on the phase of the menstrual cycle, increasing in the follicular phase. Erythrocytes found in tears against the background of accumulations of epitheliocytes and their glandular atypia may indicate a manifestation of extragenital endometriosis. Both used methods (microscopic and chemical) are informative in revealing latent haemolacria. The microscopic method is more sensitive, reveals intact erythrocytes, and besides, it provides information about other cells. At the same time, the chemical method is faster and technically simpler, it determines the presence of haemoglobin and its metabolic products, and can be used as a screening.Keywords: tear, blood, microscopy, epitheliocytes
Procedia PDF Downloads 12044 Evolution and Merging of Double-Diffusive Layers in a Vertically Stable Compositional Field
Authors: Ila Thakur, Atul Srivastava, Shyamprasad Karagadde
Abstract:
The phenomenon of double-diffusive convection is driven by density gradients created by two different components (e.g., temperature and concentration) having different molecular diffusivities. The evolution of horizontal double-diffusive layers (DDLs) is one of the outcomes of double-diffusive convection occurring in a laterally/vertically cooled rectangular cavity having a pre-existing vertically stable composition field. The present work mainly focuses on different characteristics of the formation and merging of double-diffusive layers by imposing lateral/vertical thermal gradients in a vertically stable compositional field. A CFD-based twodimensional fluent model has been developed for the investigation of the aforesaid phenomena. The configuration containing vertical thermal gradients shows the evolution and merging of DDLs, where, elements from the same horizontal plane move vertically and mix with surroundings, creating a horizontal layer. In the configuration of lateral thermal gradients, a specially oriented convective roll was found inside each DDL and each roll was driven by the competing density change due to the already existing composition field and imposed thermal field. When the thermal boundary layer near the vertical wall penetrates the salinity interface, it can disrupt the compositional interface and can lead to layer merging. Different analytical scales were quantified and compared for both configurations. Various combinations of solutal and thermal Rayleigh numbers were investigated to get three different regimes, namely; stagnant regime, layered regime and unicellular regime. For a particular solutal Rayleigh number, a layered structure can originate only for a range of thermal Rayleigh numbers. Lower thermal Rayleigh numbers correspond to a diffusion-dominated stagnant regime. Very high thermal Rayleigh corresponds to a unicellular regime with high convective mixing. Different plots identifying these three regimes, number, thickness and time of existence of DDLs have been studied and plotted. For a given solutal Rayleigh number, an increase in thermal Rayleigh number increases the width but decreases both the number and time of existence of DDLs in the fluid domain. Sudden peaks in the velocity and heat transfer coefficient have also been observed and discussed at the time of merging. The present study is expected to be useful in correlating the double-diffusive convection in many large-scale applications including oceanography, metallurgy, geology, etc. The model has also been developed for three-dimensional geometry, but the results were quite similar to that of 2-D simulations.Keywords: double diffusive layers, natural convection, Rayleigh number, thermal gradients, compositional gradients
Procedia PDF Downloads 8443 Spatial Analysis in the Impact of Aquifer Capacity Reduction on Land Subsidence Rate in Semarang City between 2014-2017
Authors: Yudo Prasetyo, Hana Sugiastu Firdaus, Diyanah Diyanah
Abstract:
The phenomenon of the lack of clean water supply in several big cities in Indonesia is a major problem in the development of urban areas. Moreover, in the city of Semarang, the population density and growth of physical development is very high. Continuous and large amounts of underground water (aquifer) exposure can result in a drastically aquifer supply declining in year by year. Especially, the intensity of aquifer use in the fulfilment of household needs and industrial activities. This is worsening by the land subsidence phenomenon in some areas in the Semarang city. Therefore, special research is needed to know the spatial correlation of the impact of decreasing aquifer capacity on the land subsidence phenomenon. This is necessary to give approve that the occurrence of land subsidence can be caused by loss of balance of pressure on below the land surface. One method to observe the correlation pattern between the two phenomena is the application of remote sensing technology based on radar and optical satellites. Implementation of Differential Interferometric Synthetic Aperture Radar (DINSAR) or Small Baseline Area Subset (SBAS) method in SENTINEL-1A satellite image acquisition in 2014-2017 period will give a proper pattern of land subsidence. These results will be spatially correlated with the aquifer-declining pattern in the same time period. Utilization of survey results to 8 monitoring wells with depth in above 100 m to observe the multi-temporal pattern of aquifer change capacity. In addition, the pattern of aquifer capacity will be validated with 2 underground water cavity maps from observation of ministries of energy and natural resources (ESDM) in Semarang city. Spatial correlation studies will be conducted on the pattern of land subsidence and aquifer capacity using overlapping and statistical methods. The results of this correlation will show how big the correlation of decrease in underground water capacity in influencing the distribution and intensity of land subsidence in Semarang city. In addition, the results of this study will also be analyzed based on geological aspects related to hydrogeological parameters, soil types, aquifer species and geological structures. The results of this study will be a correlation map of the aquifer capacity on the decrease in the face of the land in the city of Semarang within the period 2014-2017. So hopefully the results can help the authorities in spatial planning and the city of Semarang in the future.Keywords: aquifer, differential interferometric synthetic aperture radar (DINSAR), land subsidence, small baseline area subset (SBAS)
Procedia PDF Downloads 18242 Design of Photonic Crystal with Defect Layer to Eliminate Interface Corrugations for Obtaining Unidirectional and Bidirectional Beam Splitting under Normal Incidence
Authors: Evrim Colak, Andriy E. Serebryannikov, Pavel V. Usik, Ekmel Ozbay
Abstract:
Working with a dielectric photonic crystal (PC) structure which does not include surface corrugations, unidirectional transmission and dual-beam splitting are observed under normal incidence as a result of the strong diffractions caused by the embedded defect layer. The defect layer has twice the period of the regular PC segments which sandwich the defect layer. Although the PC has even number of rows, the structural symmetry is broken due to the asymmetric placement of the defect layer with respect to the symmetry axis of the regular PC. The simulations verify that efficient splitting and occurrence of strong diffractions are related to the dispersion properties of the Floquet-Bloch modes of the photonic crystal. Unidirectional and bi-directional splitting, which are associated with asymmetric transmission, arise due to the dominant contribution of the first positive and first negative diffraction orders. The effect of the depth of the defect layer is examined by placing single defect layer in varying rows, preserving the asymmetry of PC. Even for deeply buried defect layer, asymmetric transmission is still valid even if the zeroth order is not coupled. This transmission is due to evanescent waves which reach to the deeply embedded defect layer and couple to higher order modes. In an additional selected performance, whichever surface is illuminated, i.e., in both upper and lower surface illumination cases, incident beam is split into two beams of equal intensity at the output surface where the intensity of the out-going beams are equal for both illumination cases. That is, although the structure is asymmetric, symmetric bidirectional transmission with equal transmission values is demonstrated and the structure mimics the behavior of symmetric structures. Finally, simulation studies including the examination of a coupled-cavity defect for two different permittivity values (close to the permittivity values of GaAs or Si and alumina) reveal unidirectional splitting for a wider band of operation in comparison to the bandwidth obtained in the case of a single embedded defect layer. Since the dielectric materials that are utilized are low-loss and weakly dispersive in a wide frequency range including microwave and optical frequencies, the studied structures should be scalable to the mentioned ranges.Keywords: asymmetric transmission, beam deflection, blazing, bi-directional splitting, defect layer, dual beam splitting, Floquet-Bloch modes, isofrequency contours, line defect, oblique incidence, photonic crystal, unidirectionality
Procedia PDF Downloads 18441 Cytotoxicological Evaluation of a Folate Receptor Targeting Drug Delivery System Based on Cyclodextrins
Authors: Caroline Mendes, Mary McNamara, Orla Howe
Abstract:
For chemotherapy, a drug delivery system should be able to specifically target cancer cells and deliver the therapeutic dose without affecting normal cells. Folate receptors (FR) can be considered key targets since they are commonly over-expressed in cancer cells and they are the molecular marker used in this study. Here, cyclodextrin (CD) has being studied as a vehicle for delivering the chemotherapeutic drug, methotrexate (MTX). CDs have the ability to form inclusion complexes, in which molecules of suitable dimensions are included within the CD cavity. In this study, β-CD has been modified using folic acid so as to specifically target the FR molecular marker. Thus, the system studied here for drug delivery consists of β-CD, folic acid and MTX (CDEnFA:MTX). Cellular uptake of folic acid is mediated with high affinity by folate receptors while the cellular uptake of antifolates, such as MTX, is mediated with high affinity by the reduced folate carriers (RFCs). This study addresses the gene (mRNA) and protein expression levels of FRs and RFCs in the cancer cell lines CaCo-2, SKOV-3, HeLa, MCF-7, A549 and the normal cell line BEAS-2B, quantified by real-time polymerase chain reaction (real-time PCR) and flow cytometry, respectively. From that, four cell lines with different levels of FRs, were chosen for cytotoxicity assays of MTX and CDEnFA:MTX using the MTT assay. Real-time PCR and flow cytometry data demonstrated that all cell lines ubiquitously express moderate levels of RFC. These experiments have also shown that levels of FR protein in CaCo-2 cells are high, while levels in SKOV-3, HeLa and MCF-7 cells are moderate. A549 and BEAS-2B cells express low levels of FR protein. FRs are highly expressed in all the cancer cell lines analysed when compared to the normal cell line BEAS-2B. The cell lines CaCo-2, MCF-7, A549 and BEAS-2B were used in the cell viability assays. 48 hours treatment with the free drug and the complex resulted in IC50 values of 93.9 µM ± 9.2 and 56.0 µM ± 4.0 for CaCo-2 for free MTX and CDEnFA:MTX respectively, 118.2 µM ± 10.8 and 97.8 µM ± 12.3 for MCF-7, 36.4 µM ± 6.9 and 75.0 µM ± 8.5 for A549 and 132.6 µM ± 12.1 and 288.1 µM ± 16.3 for BEAS-2B. These results demonstrate that MTX is more toxic towards cell lines expressing low levels of FR, such as the BEAS-2B. More importantly, these results demonstrate that the inclusion complex CDEnFA:MTX showed greater cytotoxicity than the free drug towards the high FR expressing CaCo-2 cells, indicating that it has potential to target this receptor, enhancing the specificity and the efficiency of the drug.Keywords: cyclodextrins, cancer treatment, drug delivery, folate receptors, reduced folate carriers
Procedia PDF Downloads 30140 Physical Exam-Indicated Cerclage with Mesh Cap Prolonged Gestation on Average for 9 Weeks and 4 Days: 11 Years of Experience
Authors: M. Keršič, M. Lužnik, J. Lužnik
Abstract:
Cervical dilatation and membrane herniation before 26th week of gestation poses very high risk for extremely and very premature childbirth. Cerclage with mesh cap (mesh cerclage, MC) can greatly diminish this risk and provide additional positive effects. Between 2005 and 2014, MC has been performed in 9 patients with singleton pregnancies who had prolapsed membranes beyond external cervical/uterine os before 25th week of pregnancy (one in 29th). With patients in general anaesthesia, lithotomy and Trendelenburg position (about 25°) prolapsed membranes were repositioned in the uterine cavity, using tampon soaked in antiseptic solution (Skinsept mucosa). A circular, a type of purse-string suture (main band) with double string Ethilon 1 was applied at about 1 to 1.5 cm from the border of the external uterine os - 6 to 8 stitches were placed, so the whole external uterine os was encircled (modified McDonald). In the next step additional Ethilon 0 sutures were placed around all exposed parts of the main double circular suture and loosely tightened. On those sutures, round tailored (diameter around 6 cm) mesh (Prolene® or Gynemesh* PS) was attached. In all 9 cases, gestation was prolonged on average for 9 weeks and 4 days (67 days). In four cases maturity was achieved. Mesh was removed in 37th–38th week of pregnancy or if spontaneous labour began. In two cases, a caesarean section was performed because of breech presentation. In the first week after birth in 22nd week one new born died because of immaturity (premature birth was threatening in 18th week and then MC was placed). Ten years after first MC, 8 of 9 women with singleton pregnancy and MC performed have 8 healthy children from these pregnancies. Mesh cerclage successfully closed the opened cervical canal or uterine orifice and prevented further membrane herniation and membrane rupture. MC also provides a similar effect as with occluding the external os with suturing but without interrupting the way for excretion of abundant cervical mucus. The mesh also pulls the main circular band outwards and thus lowers the chance of suture cutting through the remaining cervix. MC prolonged gestation very successfully (mean for 9 weeks and 4 days) and thus increased possibility for survival and diminished the risk for complications in very early preterm delivered survivors in cases with cervical dilatation and membrane herniation before 26th week of gestation. Without action possibility to achieve at least 28th or 32nd week of gestation would be poor.Keywords: cervical insufficiency, mesh cerclage, membrane protrusion, premature birth prevention, physical exam-indicated cerclage, rescue cerclage
Procedia PDF Downloads 19039 The Interventricular Septum as a Site for Implantation of Electrocardiac Devices - Clinical Implications of Topography and Variation in Position
Authors: Marcin Jakiel, Maria Kurek, Karolina Gutkowska, Sylwia Sanakiewicz, Dominika Stolarczyk, Jakub Batko, Rafał Jakiel, Mateusz K. Hołda
Abstract:
Proper imaging of the interventricular septum during endocavital lead implantation is essential for successful procedure. The interventricular septum is located oblique to the 3 main body planes and forms angles of 44.56° ± 7.81°, 45.44° ± 7.81°, 62.49° (IQR 58.84° - 68.39°) with the sagittal, frontal and transverse planes, respectively. The optimal left anterior oblique (LAO) projection is to have the septum aligned along the radiation beam and will be obtained for an angle of 53.24° ± 9,08°, while the best visualization of the septal surface in the right anterior oblique (RAO) projection is obtained by using an angle of 45.44° ± 7.81°. In addition, the RAO angle (p=0.003) and the septal slope to the transverse plane (p=0.002) are larger in the male group, but the LAO angle (p=0.003) and the dihedral angle that the septum forms with the sagittal plane (p=0.003) are smaller, compared to the female group. Analyzing the optimal RAO angle in cross-sections lying at the level of the connections of the septum with the free wall of the right ventricle from the front and back, we obtain slightly smaller angle values, i.e. 41.11° ± 8.51° and 43.94° ± 7.22°, respectively. As the septum is directed leftward in the apical region, the optimal RAO angle for this area decreases (16.49° ± 7,07°) and does not show significant differences between the male and female groups (p=0.23). Within the right ventricular apex, there is a cavity formed by the apical segment of the interventricular septum and the free wall of the right ventricle with a depth of 12.35mm (IQR 11.07mm - 13.51mm). The length of the septum measured in longitudinal section, containing 4 heart cavities, is 73.03mm ± 8.06mm. With the left ventricular septal wall formed by the interventricular septum in the apical region at a length of 10.06mm (IQR 8.86 - 11.07mm) already lies outside the right ventricle. Both mentioned lengths are significantly larger in the male group (p<0.001). For proper imaging of the septum from the right ventricular side, an oblique position of the visualization devices is necessary. Correct determination of the RAO and LAO angle during the procedure allows to improve the procedure performed, and possible modification of the visual field when moving in the anterior, posterior and apical directions of the septum will avoid complications. Overlooking the change in the direction of the interventricular septum in the apical region and a significant decrease in the RAO angle can result in implantation of the lead into the free wall of the right ventricle with less effective pacing and even complications such as wall perforation and cardiac tamponade. The demonstrated gender differences can also be helpful in setting the right projections. A necessary addition to the analysis will be a description of the area of the ventricular septum, which we are currently working on using autopsy material.Keywords: anatomical variability, angle, electrocardiological procedure, intervetricular septum
Procedia PDF Downloads 9938 The MHz Frequency Range EM Induction Device Development and Experimental Study for Low Conductive Objects Detection
Authors: D. Kakulia, L. Shoshiashvili, G. Sapharishvili
Abstract:
The results of the study are related to the direction of plastic mine detection research using electromagnetic induction, the development of appropriate equipment, and the evaluation of expected results. Electromagnetic induction sensing is effectively used in the detection of metal objects in the soil and in the discrimination of unexploded ordnances. Metal objects interact well with a low-frequency alternating magnetic field. Their electromagnetic response can be detected at the low-frequency range even when they are placed in the ground. Detection of plastic things such as plastic mines by electromagnetic induction is associated with difficulties. The interaction of non-conducting bodies or low-conductive objects with a low-frequency alternating magnetic field is very weak. At the high-frequency range where already wave processes take place, the interaction increases. Interactions with other distant objects also increase. A complex interference picture is formed, and extraction of useful information also meets difficulties. Sensing by electromagnetic induction at the intermediate MHz frequency range is the subject of research. The concept of detecting plastic mines in this range can be based on the study of the electromagnetic response of non-conductive cavity in a low-conductivity environment or the detection of small metal components in plastic mines, taking into account constructive features. The detector node based on the amplitude and phase detector 'Analog Devices ad8302' has been developed for experimental studies. The node has two inputs. At one of the inputs, the node receives a sinusoidal signal from the generator, to which a transmitting coil is also connected. The receiver coil is attached to the second input of the node. The additional circuit provides an option to amplify the signal output from the receiver coil by 20 dB. The node has two outputs. The voltages obtained at the output reflect the ratio of the amplitudes and the phase difference of the input harmonic signals. Experimental measurements were performed in different positions of the transmitter and receiver coils at the frequency range 1-20 MHz. Arbitrary/Function Generator Tektronix AFG3052C and the eight-channel high-resolution oscilloscope PICOSCOPE 4824 were used in the experiments. Experimental measurements were also performed with a low-conductive test object. The results of the measurements and comparative analysis show the capabilities of the simple detector node and the prospects for its further development in this direction. The results of the experimental measurements are compared and analyzed with the results of appropriate computer modeling based on the method of auxiliary sources (MAS). The experimental measurements are driven using the MATLAB environment. Acknowledgment -This work was supported by Shota Rustaveli National Science Foundation (SRNSF) (Grant number: NFR 17_523).Keywords: EM induction sensing, detector, plastic mines, remote sensing
Procedia PDF Downloads 14937 Clinical Validation of C-PDR Methodology for Accurate Non-Invasive Detection of Helicobacter pylori Infection
Authors: Suman Som, Abhijit Maity, Sunil B. Daschakraborty, Sujit Chaudhuri, Manik Pradhan
Abstract:
Background: Helicobacter pylori is a common and important human pathogen and the primary cause of peptic ulcer disease and gastric cancer. Currently H. pylori infection is detected by both invasive and non-invasive way but the diagnostic accuracy is not up to the mark. Aim: To set up an optimal diagnostic cut-off value of 13C-Urea Breath Test to detect H. pylori infection and evaluate a novel c-PDR methodology to overcome of inconclusive grey zone. Materials and Methods: All 83 subjects first underwent upper-gastrointestinal endoscopy followed by rapid urease test and histopathology and depending on these results; we classified 49 subjects as H. pylori positive and 34 negative. After an overnight, fast patients are taken 4 gm of citric acid in 200 ml water solution and 10 minute after ingestion of the test meal, a baseline exhaled breath sample was collected. Thereafter an oral dose of 75 mg 13C-Urea dissolved in 50 ml water was given and breath samples were collected upto 90 minute for 15 minute intervals and analysed by laser based high precisional cavity enhanced spectroscopy. Results: We studied the excretion kinetics of 13C isotope enrichment (expressed as δDOB13C ‰) of exhaled breath samples and found maximum enrichment around 30 minute of H. pylori positive patients, it is due to the acid mediated stimulated urease enzyme activity and maximum acidification happened within 30 minute but no such significant isotopic enrichment observed for H. pylori negative individuals. Using Receiver Operating Characteristic (ROC) curve an optimal diagnostic cut-off value, δDOB13C ‰ = 3.14 was determined at 30 minute exhibiting 89.16% accuracy. Now to overcome grey zone problem we explore percentage dose of 13C recovered per hour, i.e. 13C-PDR (%/hr) and cumulative percentage dose of 13C recovered, i.e. c-PDR (%) in exhaled breath samples for the present 13C-UBT. We further explored the diagnostic accuracy of 13C-UBT by constructing ROC curve using c-PDR (%) values and an optimal cut-off value was estimated to be c-PDR = 1.47 (%) at 60 minute, exhibiting 100 % diagnostic sensitivity , 100 % specificity and 100 % accuracy of 13C-UBT for detection of H. pylori infection. We also elucidate the gastric emptying process of present 13C-UBT for H. pylori positive patients. The maximal emptying rate found at 36 minute and half empting time of present 13C-UBT was found at 45 minute. Conclusions: The present study exhibiting the importance of c-PDR methodology to overcome of grey zone problem in 13C-UBT for accurate determination of infection without any risk of diagnostic errors and making it sufficiently robust and novel method for an accurate and fast non-invasive diagnosis of H. pylori infection for large scale screening purposes.Keywords: 13C-Urea breath test, c-PDR methodology, grey zone, Helicobacter pylori
Procedia PDF Downloads 30136 Differentiated Surgical Treatment of Patients With Nontraumatic Intracerebral Hematomas
Authors: Mansur Agzamov, Valery Bersnev, Natalia Ivanova, Istam Agzamov, Timur Khayrullaev, Yulduz Agzamova
Abstract:
Objectives. Treatment of hypertensive intracerebral hematoma (ICH) is controversial. Advantage of one surgical method on other has not been established. Recent reports suggest a favorable effect of minimally invasive surgery. We conducted a small comparative study of different surgical methods. Methods. We analyzed the result of surgical treatment of 176 patients with intracerebral hematomas at the age from 41 to 78 years. Men were been113 (64.2%), women - 63 (35.8%). Level of consciousness: conscious -18, lethargy -63, stupor –55, moderate coma - 40. All patients on admission and in the dynamics underwent computer tomography (CT) of the brain. ICH was located in the putamen in 87 cases, thalamus in 19, in the mix area in 50, in the lobar area in 20. Ninety seven patients of them had an intraventricular hemorrhage component. The baseline volume of the ICH was measured according to a bedside method of measuring CT intracerebral hematomas volume. Depending on the intervention of the patients were divided into three groups. Group 1 patients, 90 patients, operated open craniotomy. Level of consciousness: conscious-11, lethargy-33, stupor–18, moderate coma -18. The hemorrhage was located in the putamen in 51, thalamus in 3, in the mix area in 25, in the lobar area in 11. Group 2 patients, 22 patients, underwent smaller craniotomy with endoscopic-assisted evacuation. Level of consciousness: conscious-4, lethargy-9, stupor–5, moderate coma -4. The hemorrhage was located in the putamen in 5, thalamus in 15, in the mix area in 2. Group 3 patients, 64 patients, was conducted minimally invasive removal of intracerebral hematomas using the original device (patent of Russian Federation № 65382). The device - funnel cannula - which after the special markings introduced into the hematoma cavity. Level of consciousness: conscious-3, lethargy-21, stupor–22, moderate coma -18. The hemorrhage was located in the putamen in 31, in the mix area in 23, thalamus in 1, in the lobar area in 9. Results of treatment were evaluated by Glasgow outcome scale. Results. The study showed that the results of surgical treatment in three groups depending on the degree of consciousness, the volume and localization of hematoma. In group 1, good recovery observed in 8 cases (8.9%), moderate disability in 22 (24.4%), severe disability - 17 (18.9%), death-43 (47.8%). In group 2, good recovery observed in 7 cases (31.8%), moderate disability in 7 (31.8%), severe disability - 5 (29.7%), death-7 (31.8%). In group 3, good recovery was observed in 9 cases (14.1%), moderate disability-17 (26.5%), severe disability-19 (29.7%), death-19 (29.7%). Conclusions. The method of using cannulae allowed to abandon from open craniotomy of the majority of patients with putaminal hematomas. Minimally invasive technique reduced the postoperative mortality and improves treatment outcomes of these patients.Keywords: nontraumatic intracerebral hematoma, minimal invasive surgical technique, funnel canula, differentiated surcical treatment
Procedia PDF Downloads 8335 Effects of Narghile Smoking in Tongue, Trachea and Lung
Authors: Sarah F. M. Pilati, Carolina S. Flausino, Guilherme F. Hoffmeister, Davi R. Tames, Telmo J. Mezadri
Abstract:
The effects that may be related to narghile smoking in the tissues of the oral cavity, trachea and lung and associated inflammation has been the question raised lately. The objective of this study was to identify histopathological changes and the presence of inflammation through the exposure of mice to narghile smoking through a whole-body study. The animals were divided in 4 groups with 5 animals in each group, being: one control group, one with 7 days of exposure, 15 days and the last one with 30 days. The animals were exposed to the conventional hookah smoke from Mizo brand with 0.5% percentage of unwashed tobacco and the EcOco brand coconut fiber having a dimension of 2cm × 2cm. The duration of the session was 30 minutes / day per 7, 15 and 30 days. The tobacco smoke concentration at which test animals were exposed was 35 ml every two seconds while the remaining 58 seconds were pure air. Afterward, the mice were sacrificed and submitted to histological evaluation through slices. It was found in the tongue of the 7-day group the presence in epithelium areas with acanthosis, hyperkeratosis and epithelial projections. In-depth, more intense inflammation was observed. All alteration processes increased significantly as the days of exposure increased. In trachea, with the 7-day group, there was a decrease in thickening of the pseudostratified epithelium and a slight decrease in lashes, giving rise to the metaplasia process, a process that was established in the 31-day sampling when the epithelium became stratified. In the conjunctive tissue, it was observed the presence of defense cells and formation of new vessels, evidencing the chronic inflammatory process, which decreased in the course of the samples due to the deposition of collagen fibers as seen in the 15 and 31 days groups. Among the structures of the lung, the study focused on the bronchioles and alveoli. From the 7-day group, intra-alveolar septum thickness increased, alveolar space decreased, inflammatory infiltrate with mononuclear and defense cells and new vessels formation were observed, increasing the number of red blood cells in the region. The results showed that with the passing of the days a progressive increase of the signs of changes in the region was observed, a factor that shows that narghile smoking stimulates alterations mainly in the alveoli (place where gas exchanges occur that should not present alterations) calling attention to the harmful and aggressive effect of narghile smoking. These data also highlighted the harmful effect of smoking, since the presence of acanthosis, hyperkeratosis, epithelial projections and inflammation evidences the cellular alteration process for the tongue tissue protection. Also, the narghile smoking stimulates both epithelial and inflammatory changes in the trachea, in addition to a process of metaplasia, a factor that reinforces the harmful effect and the carcinogenic potential of the narghile smoking.Keywords: metaplasia, inflammation, pathological constriction, hyperkeratosis
Procedia PDF Downloads 17334 Analysis of Aspergillus fumigatus IgG Serologic Cut-Off Values to Increase Diagnostic Specificity of Allergic Bronchopulmonary Aspergillosis
Authors: Sushmita Roy Chowdhury, Steve Holding, Sujoy Khan
Abstract:
The immunogenic responses of the lung towards the fungus Aspergillus fumigatus may range from invasive aspergillosis in the immunocompromised, fungal ball or infection within a cavity in the lung in those with structural lung lesions, or allergic bronchopulmonary aspergillosis (ABPA). Patients with asthma or cystic fibrosis are particularly predisposed to ABPA. There are consensus guidelines that have established criteria for diagnosis of ABPA, but uncertainty remains on the serologic cut-off values that would increase the diagnostic specificity of ABPA. We retrospectively analyzed 80 patients with severe asthma and evidence of peripheral blood eosinophilia ( > 500) over the last 3 years who underwent all serologic tests to exclude ABPA. Total IgE, specific IgE and specific IgG levels against Aspergillus fumigatus were measured using ImmunoCAP Phadia-100 (Thermo Fisher Scientific, Sweden). The Modified ISHAM working group 2013 criteria (obligate criteria: asthma or cystic fibrosis, total IgE > 1000 IU/ml or > 417 kU/L and positive specific IgE Aspergillus fumigatus or skin test positivity; with ≥ 2 of peripheral eosinophilia, positive specific IgG Aspergillus fumigatus and consistent radiographic opacities) was used in the clinical workup for the final diagnosis of ABPA. Patients were divided into 3 groups - definite, possible, and no evidence of ABPA. Specific IgG Aspergillus fumigatus levels were not used to assign the patients into any of the groups. Of 80 patients (males 48, females 32; mean age 53.9 years ± SD 15.8) selected for the analysis, there were 30 patients who had positive specific IgE against Aspergillus fumigatus (37.5%). 13 patients fulfilled the Modified ISHAM working group 2013 criteria of ABPA (‘definite’), while 15 patients were ‘possible’ ABPA and 52 did not fulfill the criteria (not ABPA). As IgE levels were not normally distributed, median levels were used in the analysis. Median total IgE levels of patients with definite and possible ABPA were 2144 kU/L and 2597 kU/L respectively (non-significant), while median specific IgE Aspergillus fumigatus at 4.35 kUA/L and 1.47 kUA/L respectively were significantly different (comparison of standard deviations F-statistic 3.2267, significance level p=0.040). Mean levels of IgG anti-Aspergillus fumigatus in the three groups (definite, possible and no evidence of ABPA) were compared using ANOVA (Statgraphics Centurion Professional XV, Statpoint Inc). Mean levels of IgG anti-Aspergillus fumigatus (Gm3) in definite ABPA was 125.17 mgA/L ( ± SD 54.84, with 95%CI 92.03-158.32), while mean Gm3 levels in possible and no ABPA were 18.61 mgA/L and 30.05 mgA/L respectively. ANOVA showed a significant difference between the definite group and the other groups (p < 0.001). This was confirmed using multiple range tests (Fisher's least significant difference procedure). There was no significant difference between the possible ABPA and not ABPA groups (p > 0.05). The study showed that a sizeable proportion of patients with asthma are sensitized to Aspergillus fumigatus in this part of India. A higher cut-off value of Gm3 ≥ 80 mgA/L provides a higher serologic specificity towards definite ABPA. Long-term studies would provide us more information if those patients with 'possible' APBA and positive Gm3 later develop clear ABPA, and are different from the Gm3 negative group in this respect. Serologic testing with clear defined cut-offs are a valuable adjunct in the diagnosis of ABPA.Keywords: allergic bronchopulmonary aspergillosis, Aspergillus fumigatus, asthma, IgE level
Procedia PDF Downloads 211