Search results for: invasive procedure
2480 Optical Coherence Tomography in Differentiation of Acute and Non-Healing Wounds
Authors: Ananya Barui, Provas Banerjee, Jyotirmoy Chatterjee
Abstract:
Application of optical technology in medicine and biology has a long track-record. In this endeavor, OCT is able to attract both engineers and biologists to work together in the field of photonics for establishing a striking non-invasive imaging technology. In contrast to other in vivo imaging modalities like Raman imaging, confocal imaging, two-photon microscopy etc. which can perform in vivo imaging upto 100-200 micron depth due to limitation in numerical aperture or scattering, however, OCT can achieve high-resolution imaging upto few millimeters of tissue structures depending on their refractive index in different anatomical location. This tomographic system depends on interference of two light waves in an interferometer to produce a depth profile of specimen. In wound healing, frequent collection of biopsies for follow-up of repair process could be avoided by such imaging technique. Real time skin OCT (the optical biopsy) has efficacy in deeper and faster illumination of cutaneou tissue to acquire high resolution cross sectional images of their internal micro-structure. Swept Source-OCT (SS-OCT), a novel imaging technique, can generate high-speed depth profile (~ 2 mm) of wound at a sweeping rate of laser with micron level resolution and optimum coherent length of 5-6 mm. Normally multi-layered skin tissue depicts different optical properties along with variation in thickness, refractive index and composition (i.e. keratine layer, water, fat etc.) according to their anatomical location. For instance, stratum corneum, the upper-most and relatively dehydrated layer of epidermis reflects more light and produces more lucid and a sharp demarcation line with rest of the hydrated epidermal region. During wound healing or regeneration, optical properties of cutaneous tissue continuously altered with maturation of wound bed. More mature and less hydrated tissue component reflects more light and becomes visible as a brighter area in comparison to immature region which content higher amount water or fat that depicts as a darker area in OCT image. Non-healing wound possess prolonged inflammation and inhibits nascent proliferative stage. Accumulation of necrotic tissues also prevents the repair of non-healing wounds. Due to high resolution and potentiality to reflect the compositional aspects of tissues in terms of their optical properties, this tomographic method may facilitate in differentiating non-healing and acute wounds in addition to clinical observations. Non-invasive OCT offers better insight regarding specific biological status of tissue in health and pathological conditions, OCT images could be associated with histo-pathological ‘gold standard’. This correlated SS-OCT and microscopic evaluation of the wound edges can provide information regarding progressive healing and maturation of the epithelial components. In the context of searching analogy between two different imaging modalities, their relative performances in imaging of healing bed were estimated for probing an alternative approach. Present study validated utility of SS-OCT in revealing micro-anatomic structure in the healing bed with newer information. Exploring precise correspondence of OCT images features with histo-chemical findings related to epithelial integrity of the regenerated tissue could have great implication. It could establish the ‘optical biopsy’ as a potent non-invasive diagnostic tool for cutaneous pathology.Keywords: histo-pathology, non invasive imaging, OCT, wound healing
Procedia PDF Downloads 2792479 The Possible Application of Artificial Intelligence in Hungarian Court Practice
Authors: László Schmidt
Abstract:
In the context of artificial intelligence, we need to pay primary and particular attention to ethical principles not only in the design process but also during the application process. According to the European Commission's Ethical Guidelines, AI must have three main characteristics: it must be legal, ethical and stabil. We must never lose sight of the ethical principles because we risk that this new technology will not help democratic decision-making under the rule of law, but will, on the contrary, destroy it. The rapid spread and use of artificial intelligence poses an enormous challenge to both lawmaking and law enforcement. On legislation because AI permeates many areas of our daily lives that the legislator must regulate. We can see how challenging it is to regulate e.g., selfdriving cars/taxis/vans etc. Not to mention, more recently, cryptocurrencies and Chat GPT, the use of which also requires legislative intervention, from copyright to scientific use and even law of succession. Artificial intelligence also poses an extraordinary challenge to law enforcement. In criminal cases, police and prosecutors can make great use of AI in investigations, e.g. in forensics, DNA samples, reconstruction, identification, etc. But it can also be of great help in the detection of crimes committed in cyberspace. In criminal or civil court proceedings, AI can also play a major role in the evaluation of evidence and proof. For example, a photo or video or audio recording could be immediately revealed as genuine or fake. Likewise, the authenticity or falsification of a document could be determined much more quickly and cheaply than with current procedure (expert witnesses). Neither the current Hungarian Civil Procedure Act nor the Criminal Procedure Act allows the use of artificial intelligence in the evidentiary process. However, this should be changed. To use this technology in court proceedings would be very useful. The procedures would be faster, simpler, and therefore cheaper. Artificial intelligence could also replace much of the work of expert witnesses. Its introduction into judicial procedures would certainly be justified, but with due respect for human rights, the right to a fair trial and other democratic and rule of law guarantees.Keywords: artificial intelligence, judiciary, Hungarian, court practice
Procedia PDF Downloads 782478 Testing of Complicated Bus Bar Protection Using Smart Testing Methodology
Authors: K. N. Dinesh Babu
Abstract:
In this paper, the protection of a complicated bus arrangement with a dual bus coupler and bus sectionalizer using low impedance differential protection applicable for very high voltages like 220kV and 400kV is discussed. In many power generation stations, several operational procedures are implemented to utilize the transfer bus as the main bus and to facilitate the maintenance of circuit breakers and current transformers (in each section) without shutting down the bay(s). Owing to this fact, the complications in operational philosophy have thrown challenges for the bus bar protection implementation. Many bus topologies allow any one of the main buses available in the station to be used as an auxiliary bus. In such a system, pre-defined precautions and procedures are made as guidelines, which are followed before assigning any bus as an auxiliary bus. The procedure involves shifting of links, changing rotary switches, insertion of test block, and so on, thereby causing unreliable operation. This kind of unreliable operation or inadvertent procedural lapse may result in the isolation of the bus bar from the grid due to the unpredictable operation of the bus bar protection relay, which is a commonly occurring phenomenon due to manual mistakes. With the sophisticated configuration and implementation of logic in modern intelligent electronic devices, the operator is free to select the transfer arrangement without sacrificing the protection required by a bus differential system for a reliable operation, and labor-intensive processes are completely eliminated. This paper deals with the procedure to test the security logic for such special scenarios using Megger make SMRT, bus bar protection relay to assure system stability and get rid of all the specific operational precautions/procedure.Keywords: bus bar protection, by-pass isolator, blind spot, breaker failure, intelligent electronic device, end fault, bus unification, directional principle, zones of protection, breaker re-trip, under voltage security, smart megger relay tester
Procedia PDF Downloads 682477 Development of Generally Applicable Intravenous to Oral Antibiotic Switch Therapy Criteria
Authors: H. Akhloufi, M. Hulscher, J. M. Prins, I. H. Van Der Sijs, D. Melles, A. Verbon
Abstract:
Background: A timely switch from intravenous to oral antibiotic therapy has many advantages, such as reduced incidence of IV-line related infections, a decreased hospital length of stay and less workload for healthcare professionals with equivalent patient safety. Additionally, numerous studies have demonstrated significant decreases in costs of a timely intravenous to oral antibiotic therapy switch, while maintaining efficacy and safety. However, a considerable variation in iv to oral antibiotic switch therapy criteria has been described in literature. Here, we report the development of a set of iv to oral switch criteria that are generally applicable in all hospitals. Material/methods: A RAND-modified Delphi procedure, which was composed of 3 rounds, was used. This Delphi procedure is a widely used structured process to develop consensus using multiple rounds of questionnaires within a qualified panel of selected experts. The international expert panel was multidisciplinary and composed out of clinical microbiologists, infectious disease consultants and clinical pharmacists. This panel of 19 experts appraised 6 major intravenous to oral antibiotic switch therapy criteria and operationalized these criteria using 41 measurable conditions extracted from the literature. The procedure to select a concise set of iv to oral switch criteria included 2 questionnaire rounds and a face-to-face meeting. Results: The procedure resulted in the selection of 16 measurable conditions, which operationalize 6 major intravenous to oral antibiotic switch therapy criteria. The following 6 major switch therapy criteria were selected: (1) Vital signs should be good or improving when bad. (2) Signs and symptoms related to the infection have to be resolved or improved. (3) The gastrointestinal tract has to be intact and functioning. (4) The oral route should not be compromised. (5) Absence of contra-indicated infections. (6) An oral variant of the antibiotic with good bioavailability has to exist. Conclusions: This systematic stepwise method which combined evidence and expert opinion resulted in a feasible set of 6 major intravenous to oral antibiotic switch therapy criteria operationalized by 16 measurable conditions. This set of early antibiotic iv to oral switch criteria can be used in daily practice in all adult hospital patients. Future use in audits and as rules in computer assisted decision support systems will lead to improvement of antimicrobial steward ship programs.Keywords: antibiotic resistance, antibiotic stewardship, intravenous to oral, switch therapy
Procedia PDF Downloads 3562476 Pragmatic Discoursal Study of Hedging Constructions in English Language
Authors: Mohammed Hussein Ahmed, Bahar Mohammed Kareem
Abstract:
This study is concerned with the pragmatic discoursal study of hedging constructions in English language. Hedging is a mitigated word used to lessen the impact of the utterance uttered by the speakers. Hedging could be either adverbs, adjectives, verbs and sometimes it may consist of clauses. It aims at finding out the extent to which speakers and participants of the discourse use hedging constructions during their conversations. The study also aims at finding out whether or not there are any significant differences in the types and functions of the frequency of hedging constructions employed by male and female. It is hypothesized that hedging constructions are frequent in English discourse more than any other languages due to its formality and that the frequency of the types and functions are influenced by the gender of the participants. To achieve the aims of the study, two types of procedures have been followed: theoretical and practical. The theoretical procedure consists of presenting a theoretical background of hedging topic which includes its definitions, etymology and theories. The practical procedure consists of selecting a sample of texts and analyzing them according to an adopted model. A number of conclusions will be drawn based on the findings of the study.Keywords: hedging, pragmatics, politeness, theoretical
Procedia PDF Downloads 5872475 Sensitivity Analysis of Prestressed Post-Tensioned I-Girder and Deck System
Authors: Tahsin A. H. Nishat, Raquib Ahsan
Abstract:
Sensitivity analysis of design parameters of the optimization procedure can become a significant factor while designing any structural system. The objectives of the study are to analyze the sensitivity of deck slab thickness parameter obtained from both the conventional and optimum design methodology of pre-stressed post-tensioned I-girder and deck system and to compare the relative significance of slab thickness. For analysis on conventional method, the values of 14 design parameters obtained by the conventional iterative method of design of a real-life I-girder bridge project have been considered. On the other side for analysis on optimization method, cost optimization of this system has been done using global optimization methodology 'Evolutionary Operation (EVOP)'. The problem, by which optimum values of 14 design parameters have been obtained, contains 14 explicit constraints and 46 implicit constraints. For both types of design parameters, sensitivity analysis has been conducted on deck slab thickness parameter which can become too sensitive for the obtained optimum solution. Deviations of slab thickness on both the upper and lower side of its optimum value have been considered reflecting its realistic possible ranges of variations during construction. In this procedure, the remaining parameters have been kept unchanged. For small deviations from the optimum value, compliance with the explicit and implicit constraints has been examined. Variations in the cost have also been estimated. It is obtained that without violating any constraint deck slab thickness obtained by the conventional method can be increased up to 25 mm whereas slab thickness obtained by cost optimization can be increased only up to 0.3 mm. The obtained result suggests that slab thickness becomes less sensitive in case of conventional method of design. Therefore, for realistic design purpose sensitivity should be conducted for any of the design procedure of girder and deck system.Keywords: sensitivity analysis, optimum design, evolutionary operations, PC I-girder, deck system
Procedia PDF Downloads 1372474 Influence of Glass Plates Different Boundary Conditions on Human Impact Resistance
Authors: Alberto Sanchidrián, José A. Parra, Jesús Alonso, Julián Pecharromán, Antonia Pacios, Consuelo Huerta
Abstract:
Glass is a commonly used material in building; there is not a unique design solution as plates with a different number of layers and interlayers may be used. In most façades, a security glazing have to be used according to its performance in the impact pendulum. The European Standard EN 12600 establishes an impact test procedure for classification under the point of view of the human security, of flat plates with different thickness, using a pendulum of two tires and 50 kg mass that impacts against the plate from different heights. However, this test does not replicate the actual dimensions and border conditions used in building configurations and so the real stress distribution is not determined with this test. The influence of different boundary conditions, as the ones employed in construction sites, is not well taking into account when testing the behaviour of safety glazing and there is not a detailed procedure and criteria to determinate the glass resistance against human impact. To reproduce the actual boundary conditions on site, when needed, the pendulum test is arranged to be used "in situ", with no account for load control, stiffness, and without a standard procedure. Fracture stress of small and large glass plates fit a Weibull distribution with quite a big dispersion so conservative values are adopted for admissible fracture stress under static loads. In fact, test performed for human impact gives a fracture strength two or three times higher, and many times without a total fracture of the glass plate. Newest standards, as for example DIN 18008-4, states for an admissible fracture stress 2.5 times higher than the ones used for static and wing loads. Now two working areas are open: a) to define a standard for the ‘in situ’ test; b) to prepare a laboratory procedure that allows testing with more real stress distribution. To work on both research lines a laboratory that allows to test medium size specimens with different border conditions, has been developed. A special steel frame allows reproducing the stiffness of the glass support substructure, including a rigid condition used as reference. The dynamic behaviour of the glass plate and its support substructure have been characterized with finite elements models updated with modal tests results. In addition, a new portable impact machine is being used to get enough force and direction control during the impact test. Impact based on 100 J is used. To avoid problems with broken glass plates, the test have been done using an aluminium plate of 1000 mm x 700 mm size and 10 mm thickness supported on four sides; three different substructure stiffness conditions are used. A detailed control of the dynamic stiffness and the behaviour of the plate is done with modal tests. Repeatability of the test and reproducibility of results prove that procedure to control both, stiffness of the plate and the impact level, is necessary.Keywords: glass plates, human impact test, modal test, plate boundary conditions
Procedia PDF Downloads 3072473 Confidence Levels among UK Emergency Medicine Doctors in Performing Emergency Lateral Canthotomy: Should it be a Key Skill in the ED
Authors: Mohanad Moustafa, Julia Sieberer, Rhys Davies
Abstract:
Background: Orbital compartment syndrome (OCS) is a sight-threatening Ophthalmologic emergency caused by rapidly increasing intraorbital pressure. It is usually caused by a retrobulbar hemorrhage as a result of trauma. If not treated in a timely manner, permanent vision loss can occur. Lateral canthotomy and cantholysis are minor procedures that can be performed bedside with equipment available in the emergency department. The aim of the procedure is to release the attachments between the suspensory ligaments of the eye and the bony orbital wall, leading to a decrease in intraorbital pressure and preventing irreversible loss of vision. As most Ophthalmologists across the UK provide non-resident on-call service, this may lead to a delay in the treatment of OCS and stresses the need for Emergency medical staff to be able to provide this sight-saving procedure independently. Aim: To survey current training, experience, and confidence levels among Emergency Medicine doctors in performing emergency lateral canthotomy and to establish whether these variables change the following teaching from experienced ophthalmologists. RESULTS: Most EM registrars had little to no experience in performing lateral canthotomy and cantholysis. The majority of them showed a significant increase in their confidence to perform the procedure following ophthalmic-led teaching. The survey also showed that the registrars felt such training should be added to/part of the EM curriculum. Conclusion: The involvement of Ophthalmologists in the teaching of EM doctors to recognise and treat OCS independently may prevent delays in treatment and reduce the risk of permanent sight loss. This project showed potential in improving patient care and will lead to a National Survey of EM doctors across the UK.Keywords: lateral canthotomy, retrobulbar hemorrhage, Ophthalmology, orbital compartment syndrome, sight loss, blindness
Procedia PDF Downloads 982472 User-Centered Design in the Development of Patient Decision Aids
Authors: Ariane Plaisance, Holly O. Witteman, Patrick Michel Archambault
Abstract:
Upon admission to an intensive care unit (ICU), all patients should discuss their wishes concerning life-sustaining interventions (e.g., cardiopulmonary resuscitation (CPR)). Without such discussions, interventions that prolong life at the cost of decreasing its quality may be used without appropriate guidance from patients. We employed user-centered design to adapt an existing decision aid (DA) about CPR to create a novel wiki-based DA adapted to the context of a single ICU and tailored to individual patient’s risk factors. During Phase 1, we conducted three weeks of ethnography of the decision-making context in our ICU to identify clinician and patient needs for a decision aid. During this time, we observed five dyads of intensivists and patients discussing their wishes concerning life-sustaining interventions. We also conducted semi-structured interviews with the attending intensivists in this ICU. During Phase 2, we conducted three rounds of rapid prototyping involving 15 patients and 11 other allied health professionals. We recorded discussions between intensivists and patients and used a standardized observation grid to collect patients’ comments and sociodemographic data. We applied content analysis to field notes, verbatim transcripts and the completed observation grids. Each round of observations and rapid prototyping iteratively informed the design of the next prototype. We also used the programming architecture of a wiki platform to embed the GO-FAR prediction rule programming code that we linked to a risk graphics software to better illustrate outcome risks calculated. During Phase I, we identified the need to add a section in our DA concerning invasive mechanical ventilation in addition to CPR because both life-sustaining interventions were often discussed together by physicians. During Phase II, we produced a context-adapted decision aid about CPR and mechanical ventilation that includes a values clarification section, questions about the patient’s functional autonomy prior to admission to the ICU and the functional decline that they would judge acceptable upon hospital discharge, risks and benefits of CPR and invasive mechanical ventilation, population-level statistics about CPR, a synthesis section to help patients come to a final decision and an online calculator based on the GO-FAR prediction rule. Even though the three rounds of rapid prototyping led to simplifying the information in our DA, 60% (n= 3/5) of the patients involved in the last cycle still did not understand the purpose of the DA. We also identified gaps in the discussion and documentation of patients’ preferences concerning life-sustaining interventions (e.g.,. CPR, invasive mechanical ventilation). The final version of our DA and our online wiki-based GO-FAR risk calculator using the IconArray.com risk graphics software are available online at www.wikidecision.org and are ready to be adapted to other contexts. Our results inform producers of decision aids on the use of wikis and user-centered design to develop DAs that are better adapted to users’ needs. Further work is needed on the creation of a video version of our DA. Physicians will also need the training to use our DA and to develop shared decision-making skills about goals of care.Keywords: ethnography, intensive care units, life-sustaining therapies, user-centered design
Procedia PDF Downloads 3542471 Cable De-Commissioning of Legacy Accelerators at CERN
Authors: Adya Uluwita, Fernando Pedrosa, Georgi Georgiev, Christian Bernard, Raoul Masterson
Abstract:
CERN is an international organisation funded by 23 countries that provide the particle physics community with excellence in particle accelerators and other related facilities. Founded in 1954, CERN has a wide range of accelerators that allow groundbreaking science to be conducted. Accelerators bring particles to high levels of energy and make them collide with each other or with fixed targets, creating specific conditions that are of high interest to physicists. A chain of accelerators is used to ramp up the energy of particles and eventually inject them into the largest and most recent one: the Large Hadron Collider (LHC). Among this chain of machines is, for instance the Proton Synchrotron, which was started in 1959 and is still in operation. These machines, called "injectors”, keep evolving over time, as well as the related infrastructure. Massive decommissioning of obsolete cables started in 2015 at CERN in the frame of the so-called "injectors de-cabling project phase 1". Its goal was to replace aging cables and remove unused ones, freeing space for new cables necessary for upgrades and consolidation campaigns. To proceed with the de-cabling, a project co-ordination team was assembled. The start of this project led to the investigation of legacy cables throughout the organisation. The identification of cables stacked over half a century proved to be arduous. Phase 1 of the injectors de-cabling was implemented for 3 years with success after overcoming some difficulties. Phase 2, started 3 years later, focused on improving safety and structure with the introduction of a quality assurance procedure. This paper discusses the implementation of this quality assurance procedure throughout phase 2 of the project and the transition between the two phases. Over hundreds of kilometres of cable were removed in the injectors complex at CERN from 2015 to 2023.Keywords: CERN, de-cabling, injectors, quality assurance procedure
Procedia PDF Downloads 922470 Computational Design, Simulation, and Wind Tunnel Testing of a Stabilator for a Fixed Wing Aircraft
Authors: Kartik Gupta, Umar Khan, Mayur Parab, Dhiraj Chaudhari, Afzal Ansari
Abstract:
The report focuses on the study related to the Design and Simulation of a stabilator (an all-movable horizontal stabilizer) for a fixed-wing aircraft. The project involves the development of a computerized direct optimization procedure for designing an aircraft all-movable stabilator. This procedure evaluates various design variables to synthesize an optimal stabilator that meets specific requirements, including performance, control, stability, strength, and flutter velocity constraints. The work signifies the CFD (Computational Fluid Dynamics) analysis of the airfoils used in the stabilator along with the CFD analysis of the Stabilizer and Stabilator of an aircraft named Thorp- T18 in software like XFLR5 and ANSYS-Fluent. A comparative analysis between a Stabilizer and Stabilator of equal surface area and under the same environmental conditions was done, and the percentage of drag reduced by the Stabilator for the same amount of lift generated as the Stabilizer was also calculated lastly, Wind tunnel testing was performed on a scale down model of the Stabilizer and Stabilator and the results of the Wind tunnel testing were compared with the results of CFD.Keywords: wind tunnel testing, CFD, stabilizer, stabilator
Procedia PDF Downloads 602469 Neurological Complication of Bariatric Surgery: A Cross-sectional Study from Saudi Arabia
Authors: H. A. Algahtani, A. S. Khan, O. Alzahrani, N. Hussein, M. A. Khan, Loudhi Y. I. Soliman
Abstract:
Objective: To report on the Saudi experience (developing country) of neurological complications from bariatric surgery. The literature on the subject is reviewed. Method: This is a cross sectional study done in King Abdul Aziz Medical City Jeddah, WR, where we reviewed all charts of the patients who underwent bariatric surgery between January 1st, 2009 to December 31st , 2014. Personal and clinical data including age, sex, BMI, comorbidities, type of procedure, duration of stay in hospital, complications and postoperative follow up were collected. In addition follow up visit and remote complication if present were collected. All patients with neurological complications were reviewed in details including their clinical examination, laboratory and imaging results, treatment and prognosis. This report is essentially descriptive with no statistical analysis performed. Results: Fifteen cases were collected in this study (3%). Axonal polyneuropathy was the most frequent neurological complica¬tion, but cases of Wernicke syndrome, vitamin B12 deficiency, Guillain-Barre syndrome and cupper deficiency were also identified. Fourteen patients (93.3%) had full recovery from the neurological signs and symptoms but unfortunately one patient died. Conclusion: Bariatric surgery, a procedure that is continuously increasing in popularity, is not free of potential neurological complications. A clear education, guidelines and follow-up program should be planned and practiced. Facts should be clearly presented to the individual undergoing this type of surgery. Although a clear cause-effect relation cannot be established for the present cases, the cumulative literature on the subject makes it important to warn the patient of the potential risks of this procedure.Keywords: bariatric surgery, neurological complications, neuropathy, Wenicke syndrome
Procedia PDF Downloads 3292468 The Dependence of the Liquid Application on the Coverage of the Sprayed Objects in Terms of the Characteristics of the Sprayed Object during Spraying
Authors: Beata Cieniawska, Deta Łuczycka, Katarzyna Dereń
Abstract:
When assessing the quality of the spraying procedure, three indicators are used: uneven distribution of precipitation of liquid sprayed, degree of coverage of sprayed surfaces, and deposition of liquid spraying However, there is a lack of information on the relationship between the quality parameters of the procedure. Therefore, the research was carried out at the Institute of Agricultural Engineering of Wrocław University of Environmental and Life Sciences. The aim of the study was to determine the relationship between the degree of coverage of sprayed surfaces and the deposition of liquid in the aspect of the parametric characteristics of the protected plant using selected single and double stream nozzles. Experiments were conducted under laboratory conditions. The carrier of nozzles acted as an independent self-propelled sprayer used for spraying, whereas the parametric characteristics of plants were determined using artificial plants as the ratio of the vertical projection surface and the horizontal projection surface. The results and their analysis showed a strong and very strong correlation between the analyzed parameters in terms of the characteristics of the sprayed object.Keywords: degree of coverage, deposition of liquid, nozzle, spraying
Procedia PDF Downloads 3342467 A Procedure for Post-Earthquake Damage Estimation Based on Detection of High-Frequency Transients
Authors: Aleksandar Zhelyazkov, Daniele Zonta, Helmut Wenzel, Peter Furtner
Abstract:
In the current research structural health monitoring is considered for addressing the critical issue of post-earthquake damage detection. A non-standard approach for damage detection via acoustic emission is presented - acoustic emissions are monitored in the low frequency range (up to 120 Hz). Such emissions are termed high-frequency transients. Further a damage indicator defined as the Time-Ratio Damage Indicator is introduced. The indicator relies on time-instance measurements of damage initiation and deformation peaks. Based on the time-instance measurements a procedure for estimation of the maximum drift ratio is proposed. Monitoring data is used from a shaking-table test of a full-scale reinforced concrete bridge pier. Damage of the experimental column is successfully detected and the proposed damage indicator is calculated.Keywords: acoustic emission, damage detection, shaking table test, structural health monitoring
Procedia PDF Downloads 2312466 Technology Management for Early Stage Technologies
Authors: Ming Zhou, Taeho Park
Abstract:
Early stage technologies have been particularly challenging to manage due to high degrees of their numerous uncertainties. Most research results directly out of a research lab tend to be at their early, if not the infant stage. A long while uncertain commercialization process awaits these lab results. The majority of such lab technologies go nowhere and never get commercialized due to various reasons. Any efforts or financial resources put into managing these technologies turn fruitless. High stake naturally calls for better results, which make a patenting decision harder to make. A good and well protected patent goes a long way for commercialization of the technology. Our preliminary research showed that there was not a simple yet productive procedure for such valuation. Most of the studies now have been theoretical and overly comprehensive where practical suggestions were non-existent. Hence, we attempted to develop a simple and highly implementable procedure for efficient and scalable valuation. We thoroughly reviewed existing research, interviewed practitioners in the Silicon Valley area, and surveyed university technology offices. Instead of presenting another theoretical and exhaustive research, we aimed at developing a practical guidance that a government agency and/or university office could easily deploy and get things moving to later steps of managing early stage technologies. We provided a procedure to thriftily value and make the patenting decision. A patenting index was developed using survey data and expert opinions. We identified the most important factors to be used in the patenting decision using survey ratings. The rating then assisted us in generating good relative weights for the later scoring and weighted averaging step. More importantly, we validated our procedure by testing it with our practitioner contacts. Their inputs produced a general yet highly practical cut schedule. Such schedule of realistic practices has yet to be witnessed our current research. Although a technology office may choose to deviate from our cuts, what we offered here at least provided a simple and meaningful starting point. This procedure was welcomed by practitioners in our expert panel and university officers in our interview group. This research contributed to our current understanding and practices of managing early stage technologies by instating a heuristically simple yet theoretical solid method for the patenting decision. Our findings generated top decision factors, decision processes and decision thresholds of key parameters. This research offered a more practical perspective which further completed our extant knowledge. Our results could be impacted by our sample size and even biased a bit by our focus on the Silicon Valley area. Future research, blessed with bigger data size and more insights, may want to further train and validate our parameter values in order to obtain more consistent results and analyze our decision factors for different industries.Keywords: technology management, early stage technology, patent, decision
Procedia PDF Downloads 3422465 Development of a Real-Time Simulink Based Robotic System to Study Force Feedback Mechanism during Instrument-Object Interaction
Authors: Jaydip M. Desai, Antonio Valdevit, Arthur Ritter
Abstract:
Robotic surgery is used to enhance minimally invasive surgical procedure. It provides greater degree of freedom for surgical tools but lacks of haptic feedback system to provide sense of touch to the surgeon. Surgical robots work on master-slave operation, where user is a master and robotic arms are the slaves. Current, surgical robots provide precise control of the surgical tools, but heavily rely on visual feedback, which sometimes cause damage to the inner organs. The goal of this research was to design and develop a real-time simulink based robotic system to study force feedback mechanism during instrument-object interaction. Setup includes three Velmex XSlide assembly (XYZ Stage) for three dimensional movement, an end effector assembly for forceps, electronic circuit for four strain gages, two Novint Falcon 3D gaming controllers, microcontroller board with linear actuators, MATLAB and Simulink toolboxes. Strain gages were calibrated using Imada Digital Force Gauge device and tested with a hard-core wire to measure instrument-object interaction in the range of 0-35N. Designed simulink model successfully acquires 3D coordinates from two Novint Falcon controllers and transfer coordinates to the XYZ stage and forceps. Simulink model also reads strain gages signal through 10-bit analog to digital converter resolution of a microcontroller assembly in real time, converts voltage into force and feedback the output signals to the Novint Falcon controller for force feedback mechanism. Experimental setup allows user to change forward kinematics algorithms to achieve the best-desired movement of the XYZ stage and forceps. This project combines haptic technology with surgical robot to provide sense of touch to the user controlling forceps through machine-computer interface.Keywords: surgical robot, haptic feedback, MATLAB, strain gage, simulink
Procedia PDF Downloads 5322464 Spatial Working Memory Is Enhanced by the Differential Outcome Procedure in a Group of Participants with Mild Cognitive Impairment
Authors: Ana B. Vivas, Antonia Ypsilanti, Aristea I. Ladas, Angeles F. Estevez
Abstract:
Mild Cognitive Impairment (MCI) is considered an intermediate stage between normal and pathological aging, as a substantial percentage of people diagnosed with MCI converts later to dementia of the Alzheimer’s type. Memory is of the first cognitive processes to deteriorate in this condition. In the present study we employed the differential outcomes procedure (DOP) to improve visuospatial memory in a group of participants with MCI. The DOP requires the structure of a conditional discriminative learning task in which a correct choice response to a specific stimulus-stimulus association is reinforced with a particular reinforcer or outcome. A group of 10 participants with MCI, and a matched control group had to learn and keep in working memory four target locations out of eight possible locations where a shape could be presented. Results showed that participants with MCI had a statistically significant better terminal accuracy when a unique outcome was paired with a location (76% accuracy) as compared to a non differential outcome condition (64%). This finding suggests that the DOP is useful in improving working memory in MCI patients, which may delay their conversion to dementia.Keywords: mild cognitive impairment, working memory, differential outcomes, cognitive process
Procedia PDF Downloads 4602463 Cosmetic Dermatology Procedures: Survey Results of American Society for Dermatologic Surgery
Authors: Marina S. Basta, Kirollos S. Basta
Abstract:
Cosmetic dermatology procedures have witnessed exponential growth and diversification over the last 10 years. Thus, the purpose of this study was to collect data about the latest trends for cosmetic procedures reported by dermatologists during the year 2018. This study was performed by American Society for Dermatologic Surgery (ASDS) in 2018 through sending survey invitations to 3,358 practicing dermatologists in the U.S. containing streamline questions as well as statistical questions targeted to specific analysis of cosmetic dermatology trends. Out of the targeted physicians, only 596 dermatologists reply to the survey invitation (15% overall response rate). It was noted that data collected from that survey was generalized to represent all ASDS members. Results show that there is an increase in cosmetic dermatology procedures since 12.5 million procedures were reported for 2018 compared to only 7.8 million for 2012. Injectable neuromodulators and soft tissue fillers have topped the list with a 3.7 million procedure count. Body sculpting, chemical peeling, hair transplantation, and microneedling procedures were reported to be 1.57 million cases combined. Also, the top two procedures using laser were represented in wrinkle treatment as well as sun damage correction, while the lowest two trends for laser usage were for treatments of tattoos and birthmarks. Cryolipolysis was found to be at the head of body sculpting procedures with 287,435 cases, while tumescent liposuction was reported as the least performed body sculpting procedure (18,286 cases). In conclusion, comparing the procedural trends for the last 7 years has indicated that there has been a 78% increase in soft tissue filler treatment compared to 2012. In addition, it was further noted that laser procedures scored 74% increase in the last 7 years while body contouring procedures have had four folds increase in general compared to 2012.Keywords: cosmetic dermatology, ASDS procedure survey, laser, body sculpting
Procedia PDF Downloads 1242462 A Numerical Description of a Fibre Reinforced Concrete Using a Genetic Algorithm
Authors: Henrik L. Funke, Lars Ulke-Winter, Sandra Gelbrich, Lothar Kroll
Abstract:
This work reports about an approach for an automatic adaptation of concrete formulations based on genetic algorithms (GA) to optimize a wide range of different fit-functions. In order to achieve the goal, a method was developed which provides a numerical description of a fibre reinforced concrete (FRC) mixture regarding the production technology and the property spectrum of the concrete. In a first step, the FRC mixture with seven fixed components was characterized by varying amounts of the components. For that purpose, ten concrete mixtures were prepared and tested. The testing procedure comprised flow spread, compressive and bending tensile strength. The analysis and approximation of the determined data was carried out by GAs. The aim was to obtain a closed mathematical expression which best describes the given seven-point cloud of FRC by applying a Gene Expression Programming with Free Coefficients (GEP-FC) strategy. The seven-parametric FRC-mixtures model which is generated according to this method correlated well with the measured data. The developed procedure can be used for concrete mixtures finding closed mathematical expressions, which are based on the measured data.Keywords: concrete design, fibre reinforced concrete, genetic algorithms, GEP-FC
Procedia PDF Downloads 2792461 Evaluating the Effectiveness of Science Teacher Training Programme in National Colleges of Education: a Preliminary Study, Perceptions of Prospective Teachers
Authors: A. S. V Polgampala, F. Huang
Abstract:
This is an overview of what is entailed in an evaluation and issues to be aware of when class observation is being done. This study examined the effects of evaluating teaching practice of a 7-day ‘block teaching’ session in a pre -service science teacher training program at a reputed National College of Education in Sri Lanka. Effects were assessed in three areas: evaluation of the training process, evaluation of the training impact, and evaluation of the training procedure. Data for this study were collected by class observation of 18 teachers during 9th February to 16th of 2017. Prospective teachers of science teaching, the participants of the study were evaluated based on newly introduced format by the NIE. The data collected was analyzed qualitatively using the Miles and Huberman procedure for analyzing qualitative data: data reduction, data display and conclusion drawing/verification. It was observed that the trainees showed their confidence in teaching those competencies and skills. Teacher educators’ dissatisfaction has been a great impact on evaluation process.Keywords: evaluation, perceptions & perspectives, pre-service, science teachering
Procedia PDF Downloads 3152460 Prospective Cohort Study on Sequential Use of Catheter with Misoprostol vs Misoprostol Alone for Second Trimester Medical Abortion
Authors: Hanna Teklu Gebregziabher
Abstract:
Background: A variety of techniques for medical termination of second-trimester pregnancy can be used, but there is no consensus about which is the best. Even though most evidence suggests the combined use of intracervical Foley catheter and vaginal misoprostol is safe, effective, and acceptable method for termination of second-trimester pregnancy, which is comparable to mifepristone-misoprostol combination regimen with lower cost and no additional maternal risks. The use of mifepristone and misoprostol alone with no other procedure is still the most common procedure in different institutions for 2nd-trimester pregnancy. Methods: A cross-sectional comparative prospective study design is employed on women who were admitted for 2nd-trimester medical abortion and medical abortion failed or if there was no change in cervical status after 24 hours of 1st dose of misoprostol. The study was conducted at St. Paulose Hospital Millennium Medical College. A sample of 44 participants in each arm was necessary to give a two-tailed test, a type 1 error of 5%, 80% statistical power, and a 1:1 ratio among groups. Thus, a total of 94 cases, 47 from each arm, were recruited. Data was entered and cleaned by using Epi-info and analyzed using SPSS version 29.0 statistical software and was presented in descriptive and tabular forms. Different variables were cross-tabulated and compared for significant differences and statistical analysis using the chi-square test and independent t-test, to conclude. Result: There was a significant difference between the two groups on induction to expulsion time and number of doses used. The mean ± SD of induction to expulsion time for those used misoprostol alone was 48.09 ± 11.86 and those who used trans-cervical catheter sequentially with misoprostol were 36.7 ±6.772. Conclusion: The use of a trans-cervical Foley catheter in conjunction with misoprostol in a sequential manner is a more effective, safe, and easily accessible procedure. In addition, the cost of utilizing the catheter is less compared to the cost of misoprostol and is readily available. As a good substitute, we advised using Trans-cervical Catether even for medical abortions performed in the second trimester.Keywords: second trimester, medical abortion, catheter, misoprostol
Procedia PDF Downloads 452459 Uterine Leiomyomas and Urological Complications
Authors: Dharshini Selvarajah, Nicula Lui, Karen Kong
Abstract:
Background: Uterine fibroids are a common benign gynaecologic neoplasm in reproductive-aged women. Fibroids may become symptomatic in a vast majority of nulliparous women. Their diagnosis and management is often coordinated between gyneacologists, radiologists and urologists depending on the anatomical location, growth, size and the fibroids sarcomatous evolvement. Some patients may develop obstructive uropathy symptoms, either uni or bilateral secondary urethral obstruction causing hydronephrosis. Uterine artery emoblisation (UAE) has previously shown to effectively resolve symptoms as well as relieve urethral obstruction and resolve the hydronephrosis. UAE has now established itself as an organ preserving and minimally invasive procedure in the management of symptomatic uterine fibroids. It is a safe and effective alternative to hysterectomy for resolving fibroid related pressure symptoms. The case presented examines the clinical manifestations and impact of uterine fibroids on the urinary tract system. The therapeutic options to relieve the urological symptoms as well as preserve fertility are explored and presented. Case: The case is a 29-year-old Nepalese female admitted to hospital with recurrent urosepsis with multiresistant organisms. This was on a background of an enlarged uterus (measuring 17cm x11cm) with multiple subserosal, intramural and exophytic fibroids- causing external ureteric compression. She had bilateral ureteric stents insitu and required bilateral right and left nephrostomies during repeated episodes of urosepsis and bilateral ureteric obstruction. The left nephrostomy was removed a month prior to admission and her most recent CT KUB demonstrated hypofunctioning ureteric stents with bilateral hydronephrosis. Options of hysterectomy versus uterine artery emoblisation (UAE) were extensively explored. The patient was keen to preserve fertility. Risks associated with UAE such as expulsion of the submucosal component of the fibroids and the possibilities of sepsis in the setting of ongoing ureteric colonisation were particularly high. The patient opted to trial UAE even though the risks of recurrent hospital admissions with urosepsis were going to be particularly high. In the event, the uterus fails to shrink adequately enough to relieve the obstructed ureters a hysterectomy would inevitably be required in future. Day 3 post UAE the patient developed fevers, was hypotensive and tachycardic post-receiving prophylactic meropenem and fluconazole pre emoblisation. She was noted to have a CRP of 293 with the most recent urine culture during this time growing Candida albicans. The patient was recommenced on oral fluconazole and IV meropenem, with good effect. Her repeat renal tract ultrasound post-UAE showed ongoing marked left hydronephrosis relatively unchanged from the scan one month prior to the procedure, however the right-sided hydronephrosis had resolved. The patient was discharged on a 2-week course of antibiotics. The patient will have a repeat renal tract ultrasound and MRI of the ureters to re-evaluate the degree of hydronephrosis and progress- this was unavailable at the time of abstract submission and will be presented at the conference. Conclusion: Fibroids are a common benign tumour of the uterus and can frequently impact the lower urinary system resulting in significant uropathy. They often enlarge and compress the urinary bladder, urethra and lower end of the ureters. The effectiveness of UAE as a fertility preserving option is described.Keywords: Uterine leiomyomas and urological complications, uterine artery embolisation for fibroids, Uterine fibroids and complications, Management of uterine fibroids
Procedia PDF Downloads 2232458 Strength of the Basement Wall Combined with a Temporary Retaining Wall for Excavation
Authors: Soo-yeon Seo, Su-jin Jung
Abstract:
In recent years, the need for remodeling of many apartments built 30 years ago is increasing. Therefore, researches on the structural reinforcement technology of existing apartments have been conducted. On the other hand, there is a growing need for research on the existing underground space expansion technology to expand the parking space required for remodeling. When expanding an existing underground space, for earthworks, an earth retaining wall must be installed between the existing apartment building and it. In order to maximize the possible underground space, it is necessary to minimize the thickness of the portion of earth retaining wall and underground basement wall. In this manner, the calculation procedure is studied for the evaluation of shear strength of the composite basement wall corresponding to shear span-to-depth ratio in this study. As a result, it was shown that the proposed calculation procedure can be used to evaluate the shear strength of the composite basement wall as safe. On the other hand, when shear span-to-depth ratio is small, shear strength is very underestimated.Keywords: underground space expansion, combined structure, temporary retaining wall, basement wall, shear connectors
Procedia PDF Downloads 1432457 Development of a Model for Predicting Radiological Risks in Interventional Cardiology
Authors: Stefaan Carpentier, Aya Al Masri, Fabrice Leroy, Thibault Julien, Safoin Aktaou, Malorie Martin, Fouad Maaloul
Abstract:
Introduction: During an 'Interventional Radiology (IR)' procedure, the patient's skin-dose may become very high for a burn, necrosis, and ulceration to appear. In order to prevent these deterministic effects, a prediction of the peak skin-dose for the patient is important in order to improve the post-operative care to be given to the patient. The objective of this study is to estimate, before the intervention, the patient dose for ‘Chronic Total Occlusion (CTO)’ procedures by selecting relevant clinical indicators. Materials and methods: 103 procedures were performed in the ‘Interventional Cardiology (IC)’ department using a Siemens Artis Zee image intensifier that provides the Air Kerma of each IC exam. Peak Skin Dose (PSD) was measured for each procedure using radiochromic films. Patient parameters such as sex, age, weight, and height were recorded. The complexity index J-CTO score, specific to each intervention, was determined by the cardiologist. A correlation method applied to these indicators allowed to specify their influence on the dose. A predictive model of the dose was created using multiple linear regressions. Results: Out of 103 patients involved in the study, 5 were excluded for clinical reasons and 2 for placement of radiochromic films outside the exposure field. 96 2D-dose maps were finally used. The influencing factors having the highest correlation with the PSD are the patient's diameter and the J-CTO score. The predictive model is based on these parameters. The comparison between estimated and measured skin doses shows an average difference of 0.85 ± 0.55 Gy for doses of less than 6 Gy. The mean difference between air-Kerma and PSD is 1.66 Gy ± 1.16 Gy. Conclusion: Using our developed method, a first estimate of the dose to the skin of the patient is available before the start of the procedure, which helps the cardiologist in carrying out its intervention. This estimation is more accurate than that provided by the Air-Kerma.Keywords: chronic total occlusion procedures, clinical experimentation, interventional radiology, patient's peak skin dose
Procedia PDF Downloads 1362456 Performance Based Seismic Retrofit of Masonry Infiled Reinforced Concrete Frames Using Passive Energy Dissipation Devices
Authors: Alok Madan, Arshad K. Hashmi
Abstract:
The paper presents a plastic analysis procedure based on the energy balance concept for performance based seismic retrofit of multi-story multi-bay masonry infilled reinforced concrete (R/C) frames with a ‘soft’ ground story using passive energy dissipation (PED) devices with the objective of achieving a target performance level of the retrofitted R/C frame for a given seismic hazard level at the building site. The proposed energy based plastic analysis procedure was employed for developing performance based design (PBD) formulations for PED devices for a simulated application in seismic retrofit of existing frame structures designed in compliance with the prevalent standard codes of practice. The PBD formulations developed for PED devices were implemented for simulated seismic retrofit of a representative code-compliant masonry infilled R/C frame with a ‘soft’ ground story using friction dampers as the PED device. Non-linear dynamic analyses of the retrofitted masonry infilled R/C frames is performed to investigate the efficacy and accuracy of the proposed energy based plastic analysis procedure in achieving the target performance level under design level earthquakes. Results of non-linear dynamic analyses demonstrate that the maximum inter-story drifts in the masonry infilled R/C frames with a ‘soft’ ground story that is retrofitted with the friction dampers designed using the proposed PBD formulations are controlled within the target drifts under near-field as well far-field earthquakes.Keywords: energy methods, masonry infilled frame, near-field earthquakes, seismic protection, supplemental damping devices
Procedia PDF Downloads 2982455 Management of Urological Complications Secondary to Uterine Fibroids
Authors: Dharshini Selvarajah, Karen Kong
Abstract:
Background: Uterine fibroids are a common benign gynaecologic neoplasm in reproductive-aged women. Fibroids may become symptomatic in a vast majority of nulliparous women. Their diagnosis and management are often coordinated between gyneacologists, radiologists and urologists depending on the anatomical location, growth, size and the fibroids' sarcomatous evolvement. Some patients may develop obstructive uropathy symptoms, either uni or bilateral secondary urethral obstruction causing hydronephrosis. Uterine artery embolization (UAE) has previously been shown to effectively resolve symptoms as well as relieve urethral obstruction and resolve hydronephrosis. UAE has now established itself as an organ-preserving and minimally invasive procedure in the management of symptomatic uterine fibroids. It is a safe and effective alternative to hysterectomy for resolving fibroid-related pressure symptoms. The case presented examines the clinical manifestations and impact of uterine fibroids on the urinary tract system. The therapeutic options to relieve the urological symptoms as well as preserve fertility are explored and presented. Case: The case is a 29-year-old Nepalese female admitted to the hospital with recurrent urosepsis with multiresistant organisms. This was on a background of an enlarged uterus (measuring 17cm x11cm) with multiple subserosal, intramural and exophytic fibroids- causing external ureteric compression. She had bilateral ureteric stents in situ and required bilateral right and left nephrostomies during repeated episodes of urosepsis and bilateral ureteric obstruction. The left nephrostomy was removed a month prior to admission, and her most recent CT KUB demonstrated hypofunctioning ureteric stents with bilateral hydronephrosis. Options of hysterectomy versus uterine artery embolization (UAE) were extensively explored. The patient was keen to preserve fertility. Risks associated with UAE, such as the expulsion of the submucosal component of the fibroids and the possibilities of sepsis in the setting of ongoing ureteric colonisation were particularly high. The patient opted to trial UAE even though the risks of recurrent hospital admissions with urosepsis were going to be particularly high. In the event, the uterus fails to shrink adequately enough to relieve the obstructed ureters, a hysterectomy would inevitably be required in the future. Day 3 post-UAE the patient developed fevers, was hypotensive and tachycardic post-receiving prophylactic meropenem and fluconazole pre emoblisation. She was noted to have a CRP of 293 with the most recent urine culture during this time growing Candida albicans. The patient was recommenced on oral fluconazole and IV meropenum, with good effect. Her repeat renal tract ultrasound post-UAE showed ongoing marked left hydronephrosis relatively unchanged from the scan one month prior to the procedure; however, the right-sided hydronephrosis had resolved. The patient was discharged on a 2-week course of antibiotics. The patient will have a repeat renal tract ultrasound and MRI of the ureters to re-evaluate the degree of hydronephrosis and progress- this was unavailable at the time of abstract submission and will be presented at the conference. Conclusion: Fibroids are a common benign tumor of the uterus and can frequently impact the lower urinary system resulting in significant uropathy. They often enlarge and compress the urinary bladder, urethra and lower end of the ureters. The effectiveness of the UAE as a fertility-preserving option is described.Keywords: uterine artery embolisation for fibroids, urological complications from fibroids, uropathy of fibroids, obstructive fibroid management
Procedia PDF Downloads 2092454 Non-Invasive Evaluation of Patients After Percutaneous Coronary Revascularization. The Role of Cardiac Imaging
Authors: Abdou Elhendy
Abstract:
Numerous study have shown the efficacy of the percutaneous intervention (PCI) and coronary stenting in improving left ventricular function and relieving exertional angina. Furthermore, PCI remains the main line of therapy in acute myocardial infarction. Improvement of procedural techniques and new devices have resulted in an increased number of PCI in those with difficult and extensive lesions, multivessel disease as well as total occlusion. Immediate and late outcome may be compromised by acute thrombosis or the development of fibro-intimal hyperplasia. In addition, progression of coronary artery disease proximal or distal to the stent as well as in non-stented arteries is not uncommon. As a result, complications can occur, such as acute myocardial infarction, worsened heart failure or recurrence of angina. In a stent, restenosis can occur without symptoms or with atypical complaints rendering the clinical diagnosis difficult. Routine invasive angiography is not appropriate as a follow up tool due to associated risk and cost and the limited functional assessment. Exercise and pharmacologic stress testing are increasingly used to evaluate the myocardial function, perfusion and adequacy of revascularization. Information obtained by these techniques provide important clues regarding presence and severity of compromise in myocardial blood flow. Stress echocardiography can be performed in conjunction with exercise or dobutamine infusion. The diagnostic accuracy has been moderate, but the results provide excellent prognostic stratification. Adding myocardial contrast agents can improve imaging quality and allows assessment of both function and perfusion. Stress radionuclide myocardial perfusion imaging is an alternative to evaluate these patients. The extent and severity of wall motion and perfusion abnormalities observed during exercise or pharmacologic stress are predictors of survival and risk of cardiac events. According to current guidelines, stress echocardiography and radionuclide imaging are considered to have appropriate indication among patients after PCI who have cardiac symptoms and those who underwent incomplete revascularization. Stress testing is not recommended in asymptomatic patients, particularly early after revascularization, Coronary CT angiography is increasingly used and provides high sensitive for the diagnosis of coronary artery stenosis. Average sensitivity and specificity for the diagnosis of in stent stenosis in pooled data are 79% and 81%, respectively. Limitations include blooming artifacts and low feasibility in patients with small stents or thick struts. Anatomical and functional cardiac imaging modalities are corner stone for the assessment of patients after PCI and provide salient diagnostic and prognostic information. Current imaging techniques cans serve as gate keeper for coronary angiography, thus limiting the risk of invasive procedures to those who are likely to benefit from subsequent revascularization. The determination of which modality to apply requires careful identification of merits and limitation of each technique as well as the unique characteristic of each individual patient.Keywords: coronary artery disease, stress testing, cardiac imaging, restenosis
Procedia PDF Downloads 1682453 A Probabilistic Study on Time to Cover Cracking Due to Corrosion
Authors: Chun-Qing Li, Hassan Baji, Wei Yang
Abstract:
Corrosion of steel in reinforced concrete structures is a major problem worldwide. The volume expansion of corrosion products causes concrete cover cracking, which could lead to delamination of concrete cover. The time to cover cracking plays a key role to the assessment of serviceability of reinforced concrete structures subjected to corrosion. Many analytical, numerical, and empirical models have been developed to predict the time to cracking initiation due to corrosion. In this study, a numerical model based on finite element modeling of corrosion-induced cracking process is used. In order to predict the service life based on time to cover initiation, the numerical approach is coupled with a probabilistic procedure. In this procedure, all the influential factors affecting time to cover cracking are modeled as random variables. The results show that the time to cover cracking is highly variables. It is also shown that rust product expansion ratio and the size of more porous concrete zone around the rebar are the most influential factors in predicting service life of corrosion-affected structures.Keywords: corrosion, crack width, probabilistic, service life
Procedia PDF Downloads 2072452 Use of Anti-Stick to Reduce Bitterness in Ultra Filtrated Chees-es(Single Packaged)
Authors: B. Khorram, M. Taslikh, R. Sattarzadeh, M. Ghazanfari
Abstract:
Bitterness is one of the most important problems in cheese processing industry all over the world. There are several reasons that bitterness may develop in cheese. With a few exceptions bitterness is generally associated with proteolysis. In this investigation, anti-stick as a neutral substance in proteolysis were considered and studied for reducing the problem. This vast survey was conducted in a big cheese production factory (in Neyshabur) and in the same procedure anti-stick as interested factor in cheeses packaging compared to standard cheeses production, one line productions (65200 packs with anti-stick were tested by 2953 persons for bitterness and another line was included the same procedure with standard cheese. In this investigate: 83% of standard packaging cheeses, compared with only28% of consumers cheese with anti-stick which confirmed bitterness. Although bitterness is generally associated with proteolysis and Microbial factors, Somatic cell, Starters play important role in generating bitterness in ultra filtrated cheeses, but based on the results the other factors such as anti-stick in packaging can be effective methods for reducing and removing unfavorable bitterness in cheese production.Keywords: bitterness, uf cheese, anti-stick, single packaged
Procedia PDF Downloads 4722451 Heart Rate Variability as a Measure of Dairy Calf Welfare
Authors: J. B. Clapp, S. Croarkin, C. Dolphin, S. K. Lyons
Abstract:
Chronic pain or stress in farm animals impacts both on their welfare and productivity. Measuring chronic pain or stress can be problematic using hormonal or behavioural changes because hormones are modulated by homeostatic mechanisms and observed behaviour can be highly subjective. We propose that heart rate variability (HRV) can quantify chronic pain or stress in farmed animal and represents a more robust and objective measure of their welfare.Keywords: dairy calf, welfare, heart rate variability, non-invasive, biomonitor
Procedia PDF Downloads 600