Search results for: fluorescent antibody test
9331 Double Functionalization of Magnetic Colloids with Electroactive Molecules and Antibody for Platelet Detection and Separation
Authors: Feixiong Chen, Naoufel Haddour, Marie Frenea-Robin, Yves MéRieux, Yann Chevolot, Virginie Monnier
Abstract:
Neonatal thrombopenia occurs when the mother generates antibodies against her baby’s platelet antigens. It is particularly critical for newborns because it can cause coagulation troubles leading to intracranial hemorrhage. In this case, diagnosis must be done quickly to make platelets transfusion immediately after birth. Before transfusion, platelet antigens must be tested carefully to avoid rejection. The majority of thrombopenia (95 %) are caused by antibodies directed against Human Platelet Antigen 1a (HPA-1a) or 5b (HPA-5b). The common method for antigen platelets detection is polymerase chain reaction allowing for identification of gene sequence. However, it is expensive, time-consuming and requires significant blood volume which is not suitable for newborns. We propose to develop a point-of-care device based on double functionalized magnetic colloids with 1) antibodies specific to antigen platelets and 2) highly sensitive electroactive molecules in order to be detected by an electrochemical microsensor. These magnetic colloids will be used first to isolate platelets from other blood components, then to capture specifically platelets bearing HPA-1a and HPA-5b antigens and finally to attract them close to sensor working electrode for improved electrochemical signal. The expected advantages are an assay time lower than 20 min starting from blood volume smaller than 100 µL. Our functionalization procedure based on amine dendrimers and NHS-ester modification of initial carboxyl colloids will be presented. Functionalization efficiency was evaluated by colorimetric titration of surface chemical groups, zeta potential measurements, infrared spectroscopy, fluorescence scanning and cyclic voltammetry. Our results showed that electroactive molecules and antibodies can be immobilized successfully onto magnetic colloids. Application of a magnetic field onto working electrode increased the detected electrochemical signal. Magnetic colloids were able to capture specific purified antigens extracted from platelets.Keywords: Magnetic Nanoparticles , Electroactive Molecules, Antibody, Platelet
Procedia PDF Downloads 2709330 Influence of Surface Wettability on Imbibition Dynamics of Protein Solution in Microwells
Authors: Himani Sharma, Amit Agrawal
Abstract:
Stability of the Cassie and Wenzel wetting states depends on intrinsic contact angle and geometric features on a surface that was exploited in capturing biofluids in microwells. However, the mechanism of imbibition of biofluids in the microwells is not well implied in terms of wettability of a substrate. In this work, we experimentally demonstrated filling dynamics in hydrophilic and hydrophobic microwells by protein solutions. Towards this, we utilized lotus leaf as a mold to fabricate microwells on a Polydimethylsiloxane (PDMS) surface. Lotus leaf containing micrometer-sized blunt-conical shaped pillars with a height of 8-15 µm and diameter of 3-8 µm were transferred on to PDMS. Furthermore, PDMS surface was treated with oxygen plasma to render the hydrophilic nature. A 10µL droplets containing fluorescein isothiocyanate (FITC) - labelled bovine serum albumin (BSA) were rested on both hydrophobic (θa = 108o, where θa is the apparent contact angle) and hydrophilic (θa = 60o) PDMS surfaces. A time-dependent fluorescence microscopy was conducted on these modified PDMS surfaces by recording the fluorescent intensity over a 5 minute period. It was observed that, initially (at t=1 min) FITC-BSA was accumulated on the periphery of both hydrophilic and hydrophobic microwells due to incomplete penetration of liquid-gas meniscus. This deposition of FITC-BSA on periphery of microwell was not changed with time for hydrophobic surfaces, whereas, a complete filling was occurred in hydrophilic microwells (at t=5 mins). This attributes to a gradual movement of three-phase contact line along the vertical surface of the hydrophilic microwells as compared to stable pinning in the hydrophobic microwells as confirmed by Surface Evolver simulations. In addition, if the cavities are presented on hydrophobic surfaces, air bubbles will be trapped inside the cavities once the aqueous solution is placed over these surfaces, resulting in the Cassie-Baxter wetting state. This condition hinders trapping of proteins inside the microwells. Thus, it is necessary to impart hydrophilicity to the microwell surfaces so as to induce the Wenzel state, such that, an entire solution will be fully in contact with the walls of microwells. Imbibition of microwells by protein solutions was analyzed in terms fluorescent intensity versus time. The present work underlines the importance of geometry of microwells and surface wettability of substrate in wetting and effective capturing of solid sub-phases in biofluids.Keywords: BSA, microwells, surface evolver, wettability
Procedia PDF Downloads 1989329 A Study of the Weld Properties of Inconel 625 Based on Nb Content
Authors: JongWon Han, NoHoon Kim, HyoIk Ahn, HaeWoo Lee
Abstract:
In this study, shielded metal arc welding was performed as a function of Nb content at 2.24 wt%, 3.25 wt%, and 4.26 wt%. The microstructure was observed using scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDS) and showed the development of a columnar dendrite structure in the specimen having the least Nb content. From the hardness test, the hardness value was confirmed to reduce with decreasing Nb content. From electron backscatter diffraction (EBSD) analysis, the largest grain size was found in the specimen with Nb content of 2.24 wt%. The potentiodynamic polarization test was carried out to determine the pitting corrosion resistance; there was no significant difference in the pitting corrosion resistance with increasing Nb content. To evaluate the degree of sensitization to intergranular corrosion, the Double Loop Electrochemical Potentiodynamic Reactivation(DL-EPR test) was conducted. A similar degree of sensitization was found in two specimens except with a Nb content of 2.24 wt%, while a relatively high degree of sensitization was found in the specimen with a Nb content of 2.24 wt%.Keywords: inconel 625, Nb content, potentiodynamic test, DL-EPR test
Procedia PDF Downloads 3089328 Chikungunya Virus Infection among Patients with Febrile Illness Attending University of Maiduguri Teaching Hospital, Nigeria
Authors: Abdul-Dahiru El-Yuguda, Saka Saheed Baba, Tawa Monilade Adisa, Mustapha Bala Abubakar
Abstract:
Background: Chikungunya (CHIK) virus, a previously anecdotally described arbovirus, is now assuming a worldwide public health burden. The CHIK virus infection is characterized by potentially life threatening and debilitating arthritis in addition to the high fever, arthralgia, myalgia, headache and rash. Method: Three hundred and seventy (370) serum samples were collected from outpatients with febrile illness attending University of Maiduguri Teaching Hospital, Nigeria, and was used to detect for Chikungunya (CHIK) virus IgG and IgM antibodies using the Enzyme Linked Immunosorbent Assays (ELISAs). Result: Out of the 370 sera tested, 39 (10.5%) were positive for presence of CHIK virus antibodies. A total of 24 (6.5%) tested positive for CHIK virus IgM only while none (0.0%) was positive for presence of CHIK virus IgG only and 15 (4.1%) of the serum samples were positive for both IgG and IgM antibodies. A significant difference (p<0.0001) was observed in the distribution of CHIK virus antibodies in relation to gender. The males had prevalence of 8.5% IgM antibodies as against 4.6% observed in females. On the other hand 4.6% of the females were positive for concurrent CHIK virus IgG and IgM antibodies when compared to a prevalence of 3.4% observed in males. Only the age groups ≤ 60 years and the undisclosed age group were positive for presence of CHIK virus IgG and/or IgM antibodies. No significant difference (p>0.05) was observed in the seasonal prevalence of CHIK virus antibodies among the study subjects Analysis of the prevalence of CHIK virus antibodies in relation to clinical presentation (as observed by Clinicians) of the patients revealed that headache and fever were the most frequently encountered ailments. Conclusion: The CHIK virus IgM and concurrent IgM and IgG antibody prevalence rates of 6.5% and 4.1% observed in this study indicates a current infection and the lack of IgG antibody alone observed shows that the infection is not endemic but sporadic. Recommendation: Further studies should be carried to establish the seasonal prevalence of CHIK virus infection vis-à-vis vector dynamics in the study area. A comprehensive study need to be carried out on the molecular characterization of the CHIK virus circulating in Nigeria with a view to developing CHIK virus vaccine.Keywords: Chikungunya virus, IgM and IgG antibodies, febrile patients, enzyme linked immunosorbent assay
Procedia PDF Downloads 3899327 Developing a Staff Education Program on Subglottic Suction Endotracheal Tubes
Authors: Emily Toon
Abstract:
Nurses play a critical role in the prevention of ventilator-associated pneumonia through the maintenance of endotracheal tubes and use of subglottic secretion drainage via subglottic suctioning endotracheal tubes. The purpose of this evidence based practice project is to develop a staff education program on subglottic suctioning endotracheal tubes for critical care nurses at Middlesex Health with the aim of determining and documenting increased knowledge and/or practice change. The setting included registered nurses within Middlesex Health’s critical care unit who were recruited to complete a pre-test (n=14), view a presentation, and complete a post-test (n=10). Average pre-test scores were compared to average post-test scores to determine an increase in knowledge and/or practice change. The overall mean pre-test score was 59.7 percent, compared with the mean post-test score of 88.1 percent. Pre- and post-test scores were unmatched, so statistical significance could not be determined. The hypothesis that a staff education program on subglottic suctioning endotracheal tubes would demonstrate an increase in knowledge was supported, but not statistically. By integrating a pre-test/post-test design into educational presentations to evaluate increased knowledge, data generated may be used to improve methods and practices of delivering education and enhance staff learning.Keywords: endotracheal tubes, staff education, subglottic secretion drainage, ventilator-associated pneumonia
Procedia PDF Downloads 1139326 An Integrated Tailoring Method for Thermal Cycling Tests of Spacecraft Electronics
Authors: Xin-Yan Ji, Jing Wang, Chang Liu, Yan-Qiang Bi, Zhong-Xu Xu, Xi-Yuan Li
Abstract:
Thermal tests of electronic units are critically important for the reliability validation and performance demonstration of the spacecraft hard-wares. The tailoring equation in MIL-STD-1540 is based on fatigue of solder date. In the present paper, a new test condition tailoring expression is proposed to fit different thermo-mechanical fatigue and different subsystems, by introducing an integrated evaluating method for the fatigue acceleration exponent. The validate test has been accomplished and the data has been analyzed and compared with that from the MIL-STD-1540 tailoring equations. The results are encouraging and reasonable.Keywords: thermal cycling test, thermal fatigue, tailoring equation, test condition planning
Procedia PDF Downloads 4599325 Trends in Language Testing in Primary Schools in River State, Nigeria
Authors: Okoh Chinasa, Asimuonye Augusta
Abstract:
This study investigated the trends in language testing in Primary Schools in Rivers State. English language past question papers were collected from four (4) Primary Schools in Onelga Local Government Area and Ahoada East Local Government Area. Four research questions guided the study. The study is aimed at finding out the appropriateness of test formats used for language testing and the language skills tested. The past question papers collected which served as the instrument were analyzed based on given criteria developed by the researchers in line with documentary frequency studies, a type of survey study. The study revealed that some of the four language skills were not adequately assessed and that the termly question papers were developed by a central examination body. From the past questions, it was observed that an imbalance exists in the test format used. The paper recommended that all the language skills should be tested using correct test formats to ensure that pupils were given a fair chance to show what they know and can do in English language and for teachers to be able to use the test results for effective decision making.Keywords: discrete test, integrative test, testing approach, test format
Procedia PDF Downloads 4239324 Effect of Self-Questioning Strategy on the Improvement of Reading Comprehension of ESL Learners
Authors: Muhammad Hamza
Abstract:
This research is based on the effect of self-questioning strategy on reading comprehension of second language learners at medium level. This research is conducted to find out the effects of self-questioning strategy and how self-questioning strategy helps English learners to improve their reading comprehension. In this research study the researcher has analyzed that how much self-questioning is effective in the field of learning second language and how much it helps second language learners to improve their reading comprehension. For this purpose, the researcher has studied different reading strategies, analyzed, collected data from certificate level class at NUML, Peshawar campus and then found out the effects of self-questioning strategy on reading comprehension of ESL learners. The researcher has randomly selected the participants from certificate class. The data was analyzed through pre-test and post-test and then in the final stage the results of both tests were compared. After the pre-test and post-test, the result of both pre-test and post-test indicated that if the learners start to use self-questioning strategy before reading a text, while reading a text and after reading a particular text there’ll be improvement in comprehension level of ESL learners. The present research has addressed the benefits of self-questioning strategy by taking two tests (pre and post-test).After the result of post-test it is revealed that the use of the self-questioning strategy has a significant effect on the readers’ comprehension thus, they can improve their reading comprehension by using self-questioning strategy.Keywords: strategy, self-questioning, comprehension, intermediate level ESL learner
Procedia PDF Downloads 669323 Design of a Tool for Generating Test Cases from BPMN
Authors: Prat Yotyawilai, Taratip Suwannasart
Abstract:
Business Process Model and Notation (BPMN) is more important in the business process and creating functional models, and is a standard for OMG, which becomes popular in various organizations and in education. Researches related to software testing based on models are prominent. Although most researches use the UML model in software testing, not many researches use the BPMN Model in creating test cases. Therefore, this research proposes a design of a tool for generating test cases from the BPMN. The model is analyzed and the details of the various components are extracted before creating a flow graph. Both details of components and the flow graph are used in generating test cases.Keywords: software testing, test case, BPMN, flow graph
Procedia PDF Downloads 5559322 Mutagenic in vitro Activity and Genotoxic Effect of Zygophyllum Cornutun Methanolic Extract
Authors: Awatif Boumaza, Abderraouf Hilali, Hayat Talbi, Houda Sbayou
Abstract:
The methanolic extract of Zygophyllum cornutun coss, an Algerian medicinal plant, was screened to the presence of mutagenic activity and genotoxic effect using the Ames test (Salmonella/microsome) and the micronucleus assay respectively. Positive results were obtained with both tests. The Ames test showed mutagenic activity in the presence of microsomal activation, while negative result was observed without microsomal activation. In the micronucleus test, two parameters were evaluated: the frequency of the micronucleus that increased in a dose dependent way and the proliferation index that decreased according to the micronucleus frequency. Even that further studies must be carried out, the mutagenic activity and the genotoxic effect of Zygophyllum cornutum should be taken in consideration when used as therapeutic plant.Keywords: ames test, micronucleus test, mutagenic activity, genotoxicity, Zygophyllum cornutum
Procedia PDF Downloads 5109321 Settlement Analysis of Axially Loaded Bored Piles: A Case History
Authors: M. Mert, M. T. Ozkan
Abstract:
Pile load tests should be applied to check the bearing capacity calculations and to determine the settlement of the pile corresponding to test load. Strain gauges can be installed into pile in order to determine the shaft resistance of the piles for every soil layer respectively. Detailed results can be obtained by means of strain gauges placed at certain levels into test piles. In the scope of this study, pile load test data obtained from two different projects are examined. Instrumented static pile load tests were applied on totally 7 test bored piles of different diameters (80 cm, 150 cm, and 200 cm) and different lengths (between 30-76 m) in two different project site. Settlement analysis of test piles is done by using some of load transfer methods and finite element method. Plaxis 3D which is a three-dimensional finite element program is also used for settlement analysis of the test piles. In this study, firstly bearing capacity of test piles are determined and compared with strain gauge data which is required for settlement analysis. Then, settlement values of the test piles are estimated by using load transfer methods developed in recent years and finite element method. The aim of this study is to show similarities and differences between the results obtained from settlement analysis methods and instrumented pile load tests.Keywords: failure, finite element method, monitoring and instrumentation, pile, settlement
Procedia PDF Downloads 1679320 Design of a Laboratory Test for InvestigatingPermanent Deformation of Asphalt
Authors: Esmaeil Ahmadinia, Frank Bullen, Ron Ayers
Abstract:
Many concerns have been raised in recent years about the adequacy of existing creep test methods for evaluating rut-resistance of asphalt mixes. Many researchers believe the main reason for the creep tests being unable to duplicate field results is related to a lack of a realistic confinement for laboratory specimens. In-situ asphalt under axle loads is surrounded by a mass of asphalt, which provides stress-strain generated confinement. However, most existing creep tests are largely unconfined in their nature. It has been hypothesised that by providing a degree of confinement, representative of field conditions, in a creep test, it could be possible to establish a better correlation between the field and laboratory. In this study, a new methodology is explored where confinement for asphalt specimens is provided. The proposed methodology is founded on the current Australian test method, adapted to provide simulated field conditions through the provision of sample confinement.Keywords: asphalt mixture, creep test, confinements, permanent deformation
Procedia PDF Downloads 3229319 Multi-Label Approach to Facilitate Test Automation Based on Historical Data
Authors: Warda Khan, Remo Lachmann, Adarsh S. Garakahally
Abstract:
The increasing complexity of software and its applicability in a wide range of industries, e.g., automotive, call for enhanced quality assurance techniques. Test automation is one option to tackle the prevailing challenges by supporting test engineers with fast, parallel, and repetitive test executions. A high degree of test automation allows for a shift from mundane (manual) testing tasks to a more analytical assessment of the software under test. However, a high initial investment of test resources is required to establish test automation, which is, in most cases, a limitation to the time constraints provided for quality assurance of complex software systems. Hence, a computer-aided creation of automated test cases is crucial to increase the benefit of test automation. This paper proposes the application of machine learning for the generation of automated test cases. It is based on supervised learning to analyze test specifications and existing test implementations. The analysis facilitates the identification of patterns between test steps and their implementation with test automation components. For the test case generation, this approach exploits historical data of test automation projects. The identified patterns are the foundation to predict the implementation of unknown test case specifications. Based on this support, a test engineer solely has to review and parameterize the test automation components instead of writing them manually, resulting in a significant time reduction for establishing test automation. Compared to other generation approaches, this ML-based solution can handle different writing styles, authors, application domains, and even languages. Furthermore, test automation tools require expert knowledge by means of programming skills, whereas this approach only requires historical data to generate test cases. The proposed solution is evaluated using various multi-label evaluation criteria (EC) and two small-sized real-world systems. The most prominent EC is ‘Subset Accuracy’. The promising results show an accuracy of at least 86% for test cases, where a 1:1 relationship (Multi-Class) between test step specification and test automation component exists. For complex multi-label problems, i.e., one test step can be implemented by several components, the prediction accuracy is still at 60%. It is better than the current state-of-the-art results. It is expected the prediction quality to increase for larger systems with respective historical data. Consequently, this technique facilitates the time reduction for establishing test automation and is thereby independent of the application domain and project. As a work in progress, the next steps are to investigate incremental and active learning as additions to increase the usability of this approach, e.g., in case labelled historical data is scarce.Keywords: machine learning, multi-class, multi-label, supervised learning, test automation
Procedia PDF Downloads 1329318 Ageing Deterioration of High-Density Polyethylene Cable Spacer under Salt Water Dip Wheel Test
Authors: P. Kaewchanthuek, R. Rawonghad, B. Marungsri
Abstract:
This paper presents the experimental results of high-density polyethylene cable spacers for 22 kV distribution systems under salt water dip wheel test based on IEC 62217. The strength of anti-tracking and anti-erosion of cable spacer surface was studied in this study. During the test, dry band arc and corona discharge were observed on cable spacer surface. After 30,000 cycles of salt water dip wheel test, obviously surface erosion and tracking were observed especially on the ground end. Chemical analysis results by fourier transforms infrared spectroscopy showed chemical changed from oxidation and carbonization reaction on tested cable spacer. Increasing of C=O and C=C bonds confirmed occurrence of these reactions.Keywords: cable spacer, HDPE, ageing of cable spacer, salt water dip wheel test
Procedia PDF Downloads 3799317 Design of Experiment for Optimizing Immunoassay Microarray Printing
Authors: Alex J. Summers, Jasmine P. Devadhasan, Douglas Montgomery, Brittany Fischer, Jian Gu, Frederic Zenhausern
Abstract:
Immunoassays have been utilized for several applications, including the detection of pathogens. Our laboratory is in the development of a tier 1 biothreat panel utilizing Vertical Flow Assay (VFA) technology for simultaneous detection of pathogens and toxins. One method of manufacturing VFA membranes is with non-contact piezoelectric dispensing, which provides advantages, such as low-volume and rapid dispensing without compromising the structural integrity of antibody or substrate. Challenges of this processinclude premature discontinuation of dispensing and misaligned spotting. Preliminary data revealed the Yp 11C7 mAb (11C7)reagent to exhibit a large angle of failure during printing which may have contributed to variable printing outputs. A Design of Experiment (DOE) was executed using this reagent to investigate the effects of hydrostatic pressure and reagent concentration on microarray printing outputs. A Nano-plotter 2.1 (GeSIM, Germany) was used for printing antibody reagents ontonitrocellulose membrane sheets in a clean room environment. A spotting plan was executed using Spot-Front-End software to dispense volumes of 11C7 reagent (20-50 droplets; 1.5-5 mg/mL) in a 6-test spot array at 50 target membrane locations. Hydrostatic pressure was controlled by raising the Pressure Compensation Vessel (PCV) above or lowering it below our current working level. It was hypothesized that raising or lowering the PCV 6 inches would be sufficient to cause either liquid accumulation at the tip or discontinue droplet formation. After aspirating 11C7 reagent, we tested this hypothesis under stroboscope.75% of the effective raised PCV height and of our hypothesized lowered PCV height were used. Humidity (55%) was maintained using an Airwin BO-CT1 humidifier. The number and quality of membranes was assessed after staining printed membranes with dye. The droplet angle of failure was recorded before and after printing to determine a “stroboscope score” for each run. The DOE set was analyzed using JMP software. Hydrostatic pressure and reagent concentration had a significant effect on the number of membranes output. As hydrostatic pressure was increased by raising the PCV 3.75 inches or decreased by lowering the PCV -4.5 inches, membrane output decreased. However, with the hydrostatic pressure closest to equilibrium, our current working level, membrane output, reached the 50-membrane target. As the reagent concentration increased from 1.5 to 5 mg/mL, the membrane output also increased. Reagent concentration likely effected the number of membrane output due to the associated dispensing volume needed to saturate the membranes. However, only hydrostatic pressure had a significant effect on stroboscope score, which could be due to discontinuation of dispensing, and thus the stroboscope check could not find a droplet to record. Our JMP predictive model had a high degree of agreement with our observed results. The JMP model predicted that dispensing the highest concentration of 11C7 at our current PCV working level would yield the highest number of quality membranes, which correlated with our results. Acknowledgements: This work was supported by the Chemical Biological Technologies Directorate (Contract # HDTRA1-16-C-0026) and the Advanced Technology International (Contract # MCDC-18-04-09-002) from the Department of Defense Chemical and Biological Defense program through the Defense Threat Reduction Agency (DTRA).Keywords: immunoassay, microarray, design of experiment, piezoelectric dispensing
Procedia PDF Downloads 1829316 Lifetime Assessment for Test Strips of POCT Device through Accelerated Degradation Test
Authors: Jinyoung Choi, Sunmook Lee
Abstract:
In general, single parameter, i.e. temperature, as an accelerating parameter is used to assess the accelerated stability of Point-of-Care Testing (POCT) diagnostic devices. However, humidity also plays an important role in deteriorating the strip performance since major components of test strips are proteins such as enzymes. 4 different Temp./Humi. Conditions were used to assess the lifetime of strips. Degradation of test strips were studied through the accelerated stability test and the lifetime was assessed using commercial POCT products. The life distribution of strips, which were obtained by monitoring the failure time of test strip under each stress condition, revealed that the weibull distribution was the most proper distribution describing the life distribution of strips used in the present study. Equal shape parameters were calculated to be 0.9395 and 0.9132 for low and high concentrations, respectively. The lifetime prediction was made by adopting Peck Eq. Model for Stress-Life relationship, and the B10 life was calculated to be 70.09 and 46.65 hrs for low and high concentrations, respectively.Keywords: accelerated degradation, diagnostic device, lifetime assessment, POCT
Procedia PDF Downloads 4159315 Acceleration of DNA Hybridization Using Electroosmotic Flow
Authors: Yun-Hsiang Wang, Huai-Yi Chen, Kin Fong Lei
Abstract:
Deoxyribonucleic acid (DNA) hybridization is a common technique used in genetic assay widely. However, the hybridization ratio and rate are usually limited by the diffusion effect. Here, microfluidic electrode platform producing electroosmosis generated by alternating current signal has been proposed to enhance the hybridization ratio and rate. The electrode was made of aurum fabricated by microfabrication technique. Thiol-modified oligo probe was immobilized on the electrode for specific capture of target, which is modified by fluorescent tag. Alternative electroosmosis can induce local microfluidic vortexes to accelerate DNA hybridization. This study provides a strategy to enhance the rate of DNA hybridization in the genetic assay.Keywords: DNA hybridization, electroosmosis, electrical enhancement, hybridization ratio
Procedia PDF Downloads 3839314 An Experiment Research on the Effect of Brain-Break in the Classroom on Elementary School Students’ Selective Attention
Authors: Hui Liu, Xiaozan Wang, Jiarong Zhong, Ziming Shao
Abstract:
Introduction: Related research shows that students don’t concentrate on teacher’s speaking in the classroom. The d2 attention test is a time-limited test about selective attention. The d2 attention test can be used to evaluate individual selective attention. Purpose: To use the d2 attention test tool to measure the difference between the attention level of the experimental class and the control class before and after Brain-Break and to explore the effect of Brain-Break in the classroom on students' selective attention. Methods: According to the principle of no difference in pre-test data, two classes in the fourth- grade of Shenzhen Longhua Central Primary School were selected. After 20 minutes of class in the third class in the morning and the third class in the afternoon, about 3-minute Brain-Break intervention was performed in the experimental class for 10 weeks. The normal class in the control class did not intervene. Before and after the experiment, the d2 attention test tool was used to test the attention level of the two-class students. The paired sample t-test and independent sample t-test in SPSS 23.0 was used to test the change in the attention level of the two-class classes around 10 weeks. This article only presents results with significant differences. Results: The independent sample t-test results showed that after ten-week of Brain-Break, the missed errors (E1 t = -2.165 p = 0.042), concentration performance (CP t = 1.866 p = 0.05), and the degree of omissions (Epercent t = -2.375 p = 0.029) in experimental class showed significant differences compared with control class. The students’ error level decreased and the concentration increased. Conclusions: Adding Brain-Break interventions in the classroom can effectively improve the attention level of fourth-grade primary school students to a certain extent, especially can improve the concentration of attention and decrease the error rate in the tasks. The new sport's learning model is worth promotingKeywords: cultural class, micromotor, attention, D2 test
Procedia PDF Downloads 1329313 Component Based Testing Using Clustering and Support Vector Machine
Authors: Iqbaldeep Kaur, Amarjeet Kaur
Abstract:
Software Reusability is important part of software development. So component based software development in case of software testing has gained a lot of practical importance in the field of software engineering from academic researcher and also from software development industry perspective. Finding test cases for efficient reuse of test cases is one of the important problems aimed by researcher. Clustering reduce the search space, reuse test cases by grouping similar entities according to requirements ensuring reduced time complexity as it reduce the search time for retrieval the test cases. In this research paper we proposed approach for re-usability of test cases by unsupervised approach. In unsupervised learning we proposed k-mean and Support Vector Machine. We have designed the algorithm for requirement and test case document clustering according to its tf-idf vector space and the output is set of highly cohesive pattern groups.Keywords: software testing, reusability, clustering, k-mean, SVM
Procedia PDF Downloads 4309312 Integration of Virtual Learning of Induction Machines for Undergraduates
Authors: Rajesh Kumar, Puneet Aggarwal
Abstract:
In context of understanding problems faced by undergraduate students while carrying out laboratory experiments dealing with high voltages, it was found that most of the students are hesitant to work directly on machine. The reason is that error in the circuitry might lead to deterioration of machine and laboratory instruments. So, it has become inevitable to include modern pedagogic techniques for undergraduate students, which would help them to first carry out experiment in virtual system and then to work on live circuit. Further advantages include that students can try out their intuitive ideas and perform in virtual environment, hence leading to new research and innovations. In this paper, virtual environment used is of MATLAB/Simulink for three-phase induction machines. The performance analysis of three-phase induction machine is carried out using virtual environment which includes Direct Current (DC) Test, No-Load Test, and Block Rotor Test along with speed torque characteristics for different rotor resistances and input voltage, respectively. Further, this paper carries out computer aided teaching of basic Voltage Source Inverter (VSI) drive circuitry. Hence, this paper gave undergraduates a clearer view of experiments performed on virtual machine (No-Load test, Block Rotor test and DC test, respectively). After successful implementation of basic tests, VSI circuitry is implemented, and related harmonic distortion (THD) and Fast Fourier Transform (FFT) of current and voltage waveform are studied.Keywords: block rotor test, DC test, no load test, virtual environment, voltage source inverter
Procedia PDF Downloads 3549311 Automatic Verification Technology of Virtual Machine Software Patch on IaaS Cloud
Authors: Yoji Yamato
Abstract:
In this paper, we propose an automatic verification technology of software patches for user virtual environments on IaaS Cloud to decrease verification costs of patches. In these days, IaaS services have been spread and many users can customize virtual machines on IaaS Cloud like their own private servers. Regarding to software patches of OS or middleware installed on virtual machines, users need to adopt and verify these patches by themselves. This task increases operation costs of users. Our proposed method replicates user virtual environments, extracts verification test cases for user virtual environments from test case DB, distributes patches to virtual machines on replicated environments and conducts those test cases automatically on replicated environments. We have implemented the proposed method on OpenStack using Jenkins and confirmed the feasibility. Using the implementation, we confirmed the effectiveness of test case creation efforts by our proposed idea of 2-tier abstraction of software functions and test cases. We also evaluated the automatic verification performance of environment replications, test cases extractions and test cases conductions.Keywords: OpenStack, cloud computing, automatic verification, jenkins
Procedia PDF Downloads 4889310 Near-Infrared Optogenetic Manipulation of a Channelrhodopsin via Upconverting Nanoparticles
Authors: Kanchan Yadav, Ai-Chuan Chou, Rajesh Kumar Ulaganathan, Hua-De Gao, Hsien-Ming Lee, Chien-Yuan Pan, Yit-Tsong Chen
Abstract:
Optogenetics is an innovative technology now widely adopted by researchers in different fields of the biological sciences. However, due to the weak tissue penetration capability of the short wavelengths used to activate light-sensitive proteins, an invasive light guide has been used in animal studies for photoexcitation of target tissues. Upconverting nanoparticles (UCNPs), which transform near-infrared (NIR) light to short-wavelength emissions, can help address this issue. To improve optogenetic performance, we enhance the target selectivity for optogenetic controls by specifically conjugating the UCNPs with light-sensitive proteins at a molecular level, which shortens the distance as well as enhances the efficiency of energy transfer. We tagged V5 and Lumio epitopes to the extracellular N-terminal of channelrhodopsin-2 with an mCherry conjugated at the intracellular C-terminal (VL-ChR2m) and then bound NeutrAvidin-functionalized UCNPs (NAv-UCNPs) to the VL-ChR2m via a biotinylated antibody against V5 (bV5-Ab). We observed an apparent energy transfer from the excited UCNP (donor) to the bound VL-ChR2m (receptor) by measuring emission-intensity changes at the donor-receptor complex. The successful patch-clamp electrophysiological test and an intracellular Ca2+ elevation observed in the designed UCNP-ChR2 system under optogenetic manipulation confirmed the practical employment of UCNP-assisted NIR-optogenetic functionality. This work represents a significant step toward improving therapeutic optogenetics.Keywords: Channelrhodopsin-2, near infrared, optogenetics, upconverting nanoparticles
Procedia PDF Downloads 2769309 Siderophore Receptor Protein from Klebsiella pneumoniae as a Promising Immunogen for Serotype-Independent Therapeutic Lead Development
Authors: Sweta Pandey, Samridhi Dhyani, Susmita Chaudhuri
Abstract:
Klebsiella pneumoniae causes a wide range of infections, including urinary tract infections, sepsis, bacteremia, pneumonia, and liver abscesses. The emergence of multi-drug resistance in this bacterium led to a major setback for clinical management. WHO also endorsed a need for finding alternative therapy to antibiotics for the treatment of these infections. Development of vaccines and passive antibody therapy has been proven as a potent alternative to antibiotics in the case of MDR, XDR, and PDR Klebsiella infections. Siderophore receptors have been demonstrated to be overexpressed for the internalization of iron siderophore complexes during infections in most Gram-negative bacteria. For the present study, immune response to siderophore receptors to establish this protein as a potential immunogen for the development of therapeutic leads was explored. Clinical strains of Klebsiella pneumoniae were grown in iron-deficient conditions, and the iron-regulated outer membrane proteins were extracted and characterized through mass spectrometry for specific identification. The gene for identified protein was cloned in pET- 28a vector and expressed in E. coli. The native protein and the recombinant protein were isolated and purified and used as antigens for the generation of immune response in BALB/c mice. The native protein of Klebsiella pneumoniae grown in iron-deficient conditions was identified as FepA (Ferrienterobactin receptor) and other siderophore receptors. This 80 kDa protein generated an immune response in BALB/c mice. The antiserum from mice after subsequent booster doses was collected and showed binding with FepA protein in western blot and phagocytic uptake of the K. pneumoniae in the presence antiserum from immunized mice also observed from the animal studies after bacterial challenge post immunisation in mice have shown bacterial clearance. The antiserum from mice showed binding and clearance of the Klebsiella pneumoniae bacteria in vitro and in vivo. These antigens used for generating an active immune response in mice can further be used for therapeutic monoclonal antibody development against Klebsiella pneumoniae infections.Keywords: antiserum, FepA, Klebsiella pneumoniae, multi drug resistance, siderophore receptor
Procedia PDF Downloads 1029308 Study on the Impact of Size and Position of the Shear Field in Determining the Shear Modulus of Glulam Beam Using Photogrammetry Approach
Authors: Niaz Gharavi, Hexin Zhang
Abstract:
The shear modulus of a timber beam can be determined using torsion test or shear field test method. The shear field test method is based on shear distortion measurement of the beam at the zone with the constant transverse load in the standardized four-point bending test. The current code of practice advises using two metallic arms act as an instrument to measure the diagonal displacement of the constructing square. The size and the position of the constructing square might influence the shear modulus determination. This study aimed to investigate the size and the position effect of the square in the shear field test method. A binocular stereo vision system has been employed to determine the 3D displacement of a grid of target points. Six glue laminated beams were produced and tested. Analysis of Variance (ANOVA) was performed on the acquired data to evaluate the significance of the size effect and the position effect of the square. The results have shown that the size of the square has a noticeable influence on the value of shear modulus, while, the position of the square within the area with the constant shear force does not affect the measured mean shear modulus.Keywords: shear field test method, structural-sized test, shear modulus of Glulam beam, photogrammetry approach
Procedia PDF Downloads 2919307 Targeted Delivery of Sustained Release Polymeric Nanoparticles for Cancer Therapy
Authors: Jamboor K. Vishwanatha
Abstract:
Among the potent anti-cancer agents, curcumin has been found to be very efficacious against various cancer cells. Despite multiple medicinal benefits of curcumin, poor water solubility, poor physiochemical properties and low bioavailability continue to pose major challenges in developing a formulation for clinical efficacy. To improve its potential application in the clinical area, we formulated poly lactic-co-glycolic acid (PLGA) nanoparticles. The PLGA nanoparticles were formulated using solid-oil/water emulsion solvent evaporation method and then characterized for percent yield, encapsulation efficiency, surface morphology, particle size, drug distribution within nanoparticles and drug polymer interaction. Our studies showed the successful formation of smooth and spherical curcumin loaded PLGA nanoparticles with a high percent yield of about 92.01±0.13% and an encapsulation efficiency of 90.88±0.14%. The mean particle size of the nanoparticles was found to be 145nm. The in vitro drug release profile showed 55-60% drug release from the nanoparticles over a period of 24 hours with continued sustained release over a period of 8 days. Exposure to curcumin loaded nanoparticles resulted in reduced cell viability of cancer cells compared to normal cells. We used a novel non-covalent insertion of a homo-bifunctional spacer for targeted delivery of curcumin to various cancer cells. Functionalized nanoparticles for antibody/targeting agent conjugation was prepared using a cross-linking ligand, bis(sulfosuccinimidyl) suberate (BS3), which has reactive carboxyl group to conjugate efficiently to the primary amino groups of the targeting agents. In our studies, we demonstrated successful conjugation of antibodies, Annexin A2 or prostate specific membrane antigen (PSMA), to curcumin loaded PLGA nanoparticles for targeting to prostate and breast cancer cells. The percent antibody attachment to PLGA nanoparticles was found to be 92.8%. Efficient intra-cellular uptake of the targeted nanoparticles was observed in the cancer cells. These results have emphasized the potential of our multifunctional curcumin nanoparticles to improve the clinical efficacy of curcumin therapy in patients with cancer.Keywords: polymeric nanoparticles, cancer therapy, sustained release, curcumin
Procedia PDF Downloads 3259306 Simulation of Welded Steel Tube Subjected to Internal Pressure
Authors: H. Zedira, M. T. Hannachi, H. Djebaili, B. Daheche
Abstract:
The rapid pace of technology development and strong competition in the market, prompted us to consider the field of manufacturing of steel pipes by a process complies fully with the requirements of industrial induction welding is high frequency (HF), this technique is better known today in Algeria, more precisely for the manufacture of tubes diameters Single Annabib TG Tebessa. The aim of our study is based on the characterization of processes controlling the mechanical behavior of steel pipes (type E24-2), welded by high frequency induction, considering the different tests and among the most destructive known test internal pressure. The internal pressure test is performed according to the application area of welded pipes, or as leak test, either as a test of strength (bursting). All tubes are subjected to a hydraulic test pressure of 50 bar kept at room temperature for a period of 6 seconds. This study provides information that helps optimize the design and implementation to predict the behavior of the tubes during operation.Keywords: castem, pressure, stress, tubes, thickness
Procedia PDF Downloads 3269305 A Mechanism of Reusable, Portable, and Reliable Script Generator on Android
Authors: Kuei-Chun Liu, Yu-Yu Lai, Ching-Hong Wu
Abstract:
A good automated testing tool could reduce as much as possible the manual work done by testers. Traditional record-replay testing tool provides an automated testing solution by recording mouse coordinates as test scripts, but it will be easily broken if any change of resolutions. Therefore, more and more testers design multiple test scripts to automate the testing process for different devices. In order to improve the traditional record-replay approach and reduce the effort that the testers spending on writing test scripts, we propose an approach for generating the Android application test scripts based on accessibility service without connecting to a computer. This approach simulates user input actions and replays them correctly even at the different conditions such as the internet connection is unstable when the device under test, the different resolutions on Android devices. In this paper, we describe how to generate test scripts automatically and make a comparison with existing tools for Android such as Robotium, Appium, UIAutomator, and MonkeyTalk.Keywords: accessibility service, Appium, automated testing, MonkeyTalk, Robotium, testing, UIAutomator
Procedia PDF Downloads 3789304 Inhibition of Glutamate Carboxypeptidase Activity Protects Retinal Ganglionic Cell Death Induced by Ischemia-Reperfusion by Reducing the Astroglial Activation in Rat
Authors: Dugeree Otgongerel, Kyong Jin Cho, Yu-Han Kim, Sangmee Ahn Jo
Abstract:
Excessive activation of glutamate receptor is thought to be involved in retinal ganglion cell (RGC) death after ischemia- reperfusion damage. Glutamate carboxypeptidase II (GCPII) is an enzyme responsible for the synthesis of glutamate. Several studies showed that inhibition of GCPII prevents or reduces cellular damage in brain diseases. Thus, in this study, we examined the expression of GCPII in rat retina and the role of GCPII in acute high IOP ischemia-reperfusion damage of eye by using a GCPII inhibitor, 2-(phosphonomethyl) pentanedioic acid (2-PMPA). Animal model of ischemia-reperfusion was induced by raising the intraocular pressure for 60 min and followed by reperfusion for 3 days. Rats were randomly divided into four groups: either intra-vitreous injection of 2-PMPA (11 or 110 ng per eye) or PBS after ischemia-reperfusion, 2-PMPA treatment without ischemia-reperfusion and sham-operated normal control. GCPII immunoreactivity in normal rat retina was detected weakly in retinal nerve fiber layer (RNFL) and retinal ganglionic cell layer (RGL) and also inner plexiform layer (IPL) and outer plexiform layer (OPL) strongly where are co-stained with an anti-GFAP antibody, suggesting that GCPII is expressed mostly in Muller and astrocytes. Immunostaining with anti-BRN antibody showed that ischemia- reperfusion caused RGC death (31.5 %) and decreased retinal thickness in all layers of damaged retina, but the treatment of 2-PMPA twice at 0 and 48 hour after reperfusion blocked these retinal damages. GCPII level in RNFL layer was enhanced after ischemia-reperfusion but was blocked by PMPA treatment. This result was confirmed by western blot analysis showing that the level of GCPII protein after ischemia- reperfusion increased by 2.2- fold compared to control, but this increase was blocked almost completely by 110 ng PMPA treatment. Interestingly, GFAP immunoreactivity in the retina after ischemia- reperfusion followed by treatment with PMPA showed similar pattern to GCPII, increase after ischemia-reperfusion but reduction to the normal level by PMPA treatment. Our data demonstrate that increase of GCPII protein level after ischemia-reperfusion injury is likely to cause glial activation and/or retinal cell death which are mediated by glutamate, and GCPII inhibitors may be useful in treatment of retinal disorders in which glutamate excitotoxicity is pathogenic.Keywords: glutamate carboxypepptidase II, glutamate excitotoxicity, ischemia-reperfusion, retinal ganglion cell
Procedia PDF Downloads 3409303 Exploring the Process of Change in the Identity Constructs of Adolescents Exposed to Family Violence
Authors: Charlene Petersen, Herman Grobler, Karel Botha
Abstract:
Exposure to family violence has an impact on adolescent development, more specifically the identity process. This article explores the process of change in identity constructs of adolescents’ exposed to family violence in a Cape Town community in South Africa. In order to understand the process of identity formation the article explores and describes how the meaning that these adolescents give to family violence can contribute to change in their identity constructs. A mixed method approached was used in the study. A psycho-education strategy was implemented as the intervention and pretest-post-test scales were used to assess for change after the intervention process. Twelve participants were purposely selected for the study and included both male and female adolescents with ages ranging from 15 to 18 years from three secondary schools. The research data for this article were mainly extracted from the pre-test post-test design and the psycho-education strategy of the overall research study. The research results of the psycho-education strategy were thematically analyzed and a statistical procedure was used to measure for significant change within pre-test-post-test scales. The research merely refers to the outcome of psycho-education strategy and how it correlates with the outcome of the pre-test post-test design. Adolescents’ exposure to a psycho-education strategy, as well the pre-test post-test findings reveal a change within identity construct in terms of how they perceive themselves and interaction with others in the context of family violence.Keywords: process of change in adolescent identity, family violence, psycho-education strategy, pre and post assessment
Procedia PDF Downloads 4759302 Psychological Nano-Therapy: A New Method in Family Therapy
Authors: Siamak Samani, Nadereh Sohrabi
Abstract:
Psychological nano-therapy is a new method based on systems theory. According to the theory, systems with severe dysfunctions are resistant to changes. Psychological nano-therapy helps the therapists to break this ice. Two key concepts in psychological nano-therapy are nano-functions and nano-behaviors. The most important step in psychological nano-therapy in family therapy is selecting the most effective nano-function and nano-behavior. The aim of this study was to check the effectiveness of psychological nano-therapy for family therapy. One group pre-test-post-test design (quasi-experimental Design) was applied for research. The sample consisted of ten families with severe marital conflict. The important character of these families was resistance for participating in family therapy. In this study, sending respectful (nano-function) text massages (nano-behavior) with cell phone were applied as a treatment. Cohesion/respect sub scale from self-report family processes scale and family readiness for therapy scale were used to assess all family members in pre-test and post-test. In this study, one of family members was asked to send a respectful text massage to other family members every day for a week. The content of the text massages were selected and checked by therapist. To compare the scores of families in pre-test and post-test paired sample t-test was used. The results of the test showed significant differences in both cohesion/respect score and family readiness for therapy between per-test and post-test. The results revealed that these families have found a better atmosphere for participation in a complete family therapy program. Indeed, this study showed that psychological nano-therapy is an effective method to make family readiness for therapy.Keywords: family therapy, family conflicts, nano-therapy, family readiness
Procedia PDF Downloads 659