Search results for: robotic operative system
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 17560

Search results for: robotic operative system

17320 A New Mechanical Architecture Design of a Multifunctional Bed for Bedridden Healthcare

Authors: Rogelio Portillo Vélez, Eduardo Vázquez-Santacruz, Mariano Gamboa-Zúñiga

Abstract:

In this paper a new mechanical architecture design of a multi functional robot bed, is presented. The importance of this design relies on the fact that in next years the need of assistive devices development will increase in such way that elderly patients will use this kind of devices. This mechanical design implies following specific mechanisms which attend Mexican hospital requirements. This design is the base of next step of this kind of development given that it shows all technical details of the mechanical systems which are needed in order to construct the bed. This is first hospital bed design which could responds to the Latin America hospital requirements. We have obtained these hospital requirements using our diagnosis methodology [14]. From these results we have designed the mechanical system. This is the mechanical base of the hospital robotic bed which is being developed in our robotics laboratory. It will be useful in different hospital environments for elderly and disabled patients.

Keywords: assistive robotics, methodology, feasibility analysis, robotics, operational feasibility, assistive technology, viability analysis matrix, social impact

Procedia PDF Downloads 362
17319 The Thermal Simulation of Hydraulic Cable Drum Trailers 15-Ton

Authors: Ahmad Abdul-Razzak Aboudi Al-Issa

Abstract:

Thermal is the main important aspect in any hydraulic system since it is affected on the hydraulic system performance. Therefore must be simulated the hydraulic system -that was designed- in this aspect before constructing it. In this study, an existed expert system was using to simulate the thermal aspect of a designed hydraulic system that will be used in an industrial field. The expert system which is used in this study is (Hydraulic System Calculations), and its symbol (HSC). HSC had been designed and coded in an interactive program userfriendly named (Microsoft Visual Basic 2010).

Keywords: fluid power, hydraulic system, thermal and hydrodynamic, expert system

Procedia PDF Downloads 467
17318 Fibrin Glue Reinforcement of Choledochotomy Closure Suture Line for Prevention of Bile Leak in Patients Undergoing Laparoscopic Common Bile Duct Exploration with Primary Closure: A Pilot Study

Authors: Rahul Jain, Jagdish Chander, Anish Gupta

Abstract:

Introduction: Laparoscopic common bile duct exploration (LCBDE) allows cholecystectomy and the removal of common bile duct (CBD) stones to be performed during the same sitting, thereby decreasing hospital stay. CBD exploration through choledochotomy can be closed primarily with an absorbable suture material, but can lead to biliary leakage postoperatively. In this study we tried to find a solution to further lower the incidence of bile leakage by using fibrin glue to reinforce the sutures put on choledochotomy suture line. It has haemostatic and sealing action, through strengthening the last step of the physiological coagulation and biostimulation, which favours the formation of new tissue matrix. Methodology: This study was conducted at a tertiary care teaching hospital in New Delhi, India, from 2011 to 2013. 20 patients with CBD stones documented on MRCP with CBD diameter of 9 mm or more were included in this study. Patients were randomized into two groups namely Group A in which choledochotomy was closed with polyglactin 4-0 suture and suture line reinforced with fibrin glue, and Group ‘B’ in which choledochotomy was closed with polyglactin 4-0 suture alone. Both the groups were evaluated and compared on clinical parameters such as operative time, drain content, drain output, no. of days drain was required, blood loss & transfusion requirements, length of postoperative hospital stay and conversion to open surgery. Results: The operative time for Group A ranged from 60 to 210 min (mean 131.50 min) and Group B 65 to 300 min (mean 140 minutes). The blood loss in group A ranged from 10 to 120 ml (mean 51.50 ml), in group B it ranged from 10 to 200 ml (mean 53.50 ml). In Group A, there was no case of bile leak but there was bile leak in 2 cases in Group B, minimum 0 and maximum 900 ml with a mean of 97 ml and p value of 0.147 with no statistically significant difference in bile leak in test and control groups. The minimum and maximum serous drainage in Group A was nil & 80 ml (mean 11 ml) and in Group B was nil & 270 ml (mean 72.50 ml). The p value came as 0.028 which is statistically significant. Thus serous leakage in Group A was significantly less than in Group B. The drains in Group A were removed from 2 to 4 days (mean: 3 days) while in Group B from 2 to 9 days (mean: 3.9 days). The patients in Group A stayed in hospital post operatively from 3 to 8 days (mean: 5.30) while in Group B it ranged from 3 to 10 days with a mean of 5 days. Conclusion: Fibrin glue application on CBD decreases bile leakage but in statistically insignificant manner. Fibrin glue application on CBD can significantly decrease post operative serous drainage after LCBDE. Fibrin glue application on CBD is safe and easy technique without any significant adverse effects and can help less experienced surgeons performing LCBDE.

Keywords: bile leak, fibrin glue, LCBDE, serous leak

Procedia PDF Downloads 187
17317 Efficacy of Biofeedback-Assisted Pelvic Floor Muscle Training on Postoperative Stress Urinary Incontinence

Authors: Asmaa M. El-Bandrawy, Afaf M. Botla, Ghada E. El-Refaye, Hassan O. Ghareeb

Abstract:

Background: Urinary incontinence is a common problem among adults. Its incidence increases with age and it is more frequent in women. Pelvic floor muscle training (PFMT) is the first-line therapy in the treatment of pelvic floor dysfunction (PFD) either alone or combined with biofeedback-assisted PFMT. The aim of the work: The purpose of this study is to evaluate the efficacy of biofeedback-assisted PFMT in postoperative stress urinary incontinence. Settings and Design: A single blind controlled trial design was. Methods and Material: This study was carried out in 30 volunteer patients diagnosed as severe degree of stress urinary incontinence and they were admitted to surgical treatment. They were divided randomly into two equal groups: (Group A) consisted of 15 patients who had been treated with post-operative biofeedback-assisted PFMT and home exercise program (Group B) consisted of 15 patients who had been treated with home exercise program only. Assessment of all patients in both groups (A) and (B) was carried out before and after the treatment program by measuring intra-vaginal pressure in addition to the visual analog scale. Results: At the end of the treatment program, there was a highly statistically significant difference between group (A) and group (B) in the intra-vaginal pressure and the visual analog scale favoring the group (A). Conclusion: biofeedback-assisted PFMT is an effective method for the symptomatic relief of post-operative female stress urinary incontinence.

Keywords: stress urinary incontinence, pelvic floor muscles, pelvic floor exercises, biofeedback

Procedia PDF Downloads 280
17316 Comparative Study of Outcomes of Nonfixation of Mesh versus Fixation in Laparoscopic Total Extra Peritoneal (TEP) Repair of Inguinal Hernia: A Prospective Randomized Controlled Trial

Authors: Raman Sharma, S. K. Jain

Abstract:

Aims and Objectives: Fixation of the mesh during laparoscopic total extraperitoneal (TEP) repair of inguinal hernia is thought to be necessary to prevent recurrence. However, mesh fixation may increase surgical complications and postoperative pain. Our objective was to compare the outcomes of nonfixation with fixation of polypropylene mesh by metal tacks during TEP repair of inguinal hernia. Methods: Forty patients aged 18 to72 years with inguinal hernia were included who underwent laparoscopic TEP repair of inguinal hernia with (n=20) or without (n=20) fixation of the mesh. The outcomes were operative duration, postoperative pain score, cost, in-hospital stay, time to return to normal activity, and complications. Results: Patients in whom the mesh was not fixed had shorter mean operating time (p < 0.05). We found no difference between groups in the postoperative pain score, incidence of recurrence, in-hospital stay, time to return to normal activity and complications (P > 0.05). Moreover, a net cost savings was realized for each hernia repair performed without stapled mesh. Conclusions: TEP repair without mesh fixation resulted in the shorter operating time and lower operative cost with no difference between groups in the postoperative pain score, incidence of recurrence, in-hospital stay, time to return to normal activity and complications. All this contribute to make TEP repair without mesh fixation a better choice for repair of uncomplicated inguinal hernia, especially in developing nations with scarce resources.

Keywords: postoperative pain score, inguinal hernia, nonfixation of mesh, total extra peritoneal (TEP)

Procedia PDF Downloads 313
17315 Annual Audit for the Year 2021 for Patients with Hyperparathyroidism: Not as Rare an Entity as We Believe

Authors: Antarip Bhattacharya, Dhritiman Maitra

Abstract:

Primary hyperparathyroidism (PHPT) is the most common cause of hypercalcemia due to autonomous production of parathormone (PTH) and the third most common endocrine disorder. Upto 2% of postmenopausal women could have this condition. Primary hyperparathyroidism is characterized by hypercalcemia with a high or insufficiently suppressed level of parathyroid hormone and is caused by a solitary parathyroid adenoma in 85-90% of patients. PHPT may also be caused by parathyroid hyperplasia (involving multiple glands) or parathyroid carcinoma. Associated morbidities and sequelae include decreased bone mineral density, fractures, kidney stones, hypertension, cardiac comorbidities and psychiatric disorder which entail huge costs for treatment. In the year 2021, by virtue of running a Breast and Endocrine Surgery clinic in a Tier 1 city at a tertiary care hospital, the opportunity to be associated with patients of hyperparathyroidism came our way. Here, we shall describe the spectrum of clinical presentations and customisation of treatment for parathyroid diseases with reference to the above patients. A retrospective analysis of the data of all patients presenting with symptoms of parathyroid diseases was made and classified according to the cause. 13 patients had presented with symptoms of hyperparathyroidism and each case presented with unique symptoms and necessitated detailed evaluation. The treatment or surgery offered to each patient was tailored to his/her individual disease and led to favourable outcomes. Diseases affecting parathyroid are not as rare as we believe. Each case merits detailed clinical evaluation, investigations and tailoring of suitable treatment with regard to medical management and extent of surgery. Intra-operative frozen section/iOPTH monitoring are really useful adjuncts for intra-operative decision making.

Keywords: hyperparathyroidism, parathyroid adenoma, parathyroid surgery, PTH

Procedia PDF Downloads 94
17314 Rectus Sheath Block to Extend the Effectiveness of Post Operative Epidural Analgesia

Authors: Sugam Kale, Arif Uzair Bin Mohammed Roslan, Cindy Lee, Syed Beevee Mohammed Ismail

Abstract:

Preemptive analgesia is an established concept in the modern practice of anaesthesia. To be most effective, it is best instituted earlier than the surgical stimulus and should last beyond the offset of surgically induced pain till healing is complete. Whereas the start of afferent pain blockade with regional anaesthesia is common, its effect often falls short to cover the entire period of pain impulses making their way to CNS in the post-operative period. We tried to use a combination of two regional anaesthetic techniques used sequentially to overcome this handicap. Madam S., a 56 year old lady, was scheduled for elective surgery for pancreatic cancer. She underwent laparotomy and distal pancreatectomy, splenectomy, bilateral salpingo oophorectomy, and sigmoid colectomy. Surgery was expected to be extensive, and it was presumed that the standard pain relief with PCA with opiates and oral analgesics would not be adequate. After counselling the patient pre-operative about the technique of regional anaesthesia techniques, including epidural catheterization and rectus sheath catheter placement, their benefits, and potential complications, informed consent was obtained. Epidural catheter was placed awake, and general anaesthesia was then induced. Epidural infusion of local anaesthetics was started prior to surgical incision and was continued till 60 hours into the postoperative period. Before skin closure, the surgeons inserted commercially available rectus sheath catheters bilaterally along the midline incision used for laparotomy. After 46 hours post-op, local anaesthetic infusion via these was started as bridging while the epidural infusion rate was tapered off. The epidural catheter was removed at 75 hours. Elastomeric pumps were used to provide local anaesthetic infusion with the ability to vary infusion rates. Acute pain service followed up the patient’s vital signs and effectiveness of pain relief twice daily or more frequently as required. Rectus sheath catheters were removed 137 hours post-op. The patient had good post-op analgesia with the minimal additional analgesic requirement. For the most part, the visual analog score (VAS) for pain remained at 1-3 on a scale of 1 to 10. Haemodynamics remained stable, and surgical recovery was as expected. Minimal opiate requirement after an extensive laparotomy also translates to the early return of intestinal motility. Our experience was encouraging, and we are hoping to extend this combination of two regional anaesthetic techniques to patients undergoing similar surgeries. Epidural analgesia is denser and offers excellent pain relief for both visceral and somatic pain in the first few days after surgery. As the pain intensity grows weaker, rectus sheath block and oral analgesics provide almost the same degree of pain relief after the epidural catheter is removed. We discovered that the background infusion of local anaesthetic down the rectus sheath catherter largely reduced the requirement for other classes of analgesics. We aim to study this further with a larger patient cohort and hope that it may become an established clinical practice that benefits patients everywhere.

Keywords: rectus sheath, epidural infusion, post operative analgesia, elastomeric

Procedia PDF Downloads 103
17313 Human Gesture Recognition for Real-Time Control of Humanoid Robot

Authors: S. Aswath, Chinmaya Krishna Tilak, Amal Suresh, Ganesh Udupa

Abstract:

There are technologies to control a humanoid robot in many ways. But the use of Electromyogram (EMG) electrodes has its own importance in setting up the control system. The EMG based control system helps to control robotic devices with more fidelity and precision. In this paper, development of an electromyogram based interface for human gesture recognition for the control of a humanoid robot is presented. To recognize control signs in the gestures, a single channel EMG sensor is positioned on the muscles of the human body. Instead of using a remote control unit, the humanoid robot is controlled by various gestures performed by the human. The EMG electrodes attached to the muscles generates an analog signal due to the effect of nerve impulses generated on moving muscles of the human being. The analog signals taken up from the muscles are supplied to a differential muscle sensor that processes the given signal to generate a signal suitable for the microcontroller to get the control over a humanoid robot. The signal from the differential muscle sensor is converted to a digital form using the ADC of the microcontroller and outputs its decision to the CM-530 humanoid robot controller through a Zigbee wireless interface. The output decision of the CM-530 processor is sent to a motor driver in order to control the servo motors in required direction for human like actions. This method for gaining control of a humanoid robot could be used for performing actions with more accuracy and ease. In addition, a study has been conducted to investigate the controllability and ease of use of the interface and the employed gestures.

Keywords: electromyogram, gesture, muscle sensor, humanoid robot, microcontroller, Zigbee

Procedia PDF Downloads 381
17312 Laparoscopic Curative Resection for Right-Sided Colonic Tumours: Initial Experience from a Cancer Hospital of a Developing Country

Authors: Awais Naeem, Osama Shakeel, Aamir Ali Syed, Shahid Khattak

Abstract:

Introduction: Laparoscopic right hemicolectomy is an advanced cancer surgery in today's era. The aim of this study was to evaluate the surgical and initial oncological outcomes after curative, laparoscopic resection of right sided colonic tumors. Also to compare our results with those of previous randomized trials. Methods And Procedures: We retrospectively analyzed the medical record files of all the patients who presented to our hospital with the diagnosis of right sided colon carcinoma from January 2012 to December 2017 and underwent laparoscopic right hemicolectomy. Demographics, operative findings and histopathological reports were all recorded on a preformed data sheet. All the analysis was performed on SPSS 20. Results: Total of 48 patients were included. There were 37 male and 11 female patients with mean age of 49.7 (range from 25 – 82). Mean hospital stay was 8.25 ± 3.17 days. Blood loss was 80mls and operative mean time was 240 minutes. Eighteen patients had extended right hemicolectomy. Median length of the specimen retrieved was 31cm (range, 14-59cm). Mean size of tumor was 6.44cm + 2.53. Total number of lymph nodes removed was 20.5 + 8.3. All had R0 resection. Post-operatively 2 patients had pelvic collection and there was no 30 day mortality. In 33 patients there was T3 disease, 5 had T2 and 10 had T4 disease. There was distant recurrence in 4 patients with peritoneal metastasis in 3 and liver metastasis in 1 patient. Forty-six patients are still alive and 44 are disease free. The mean follow-up period was 25.31 (12 to 60) months. Conclusion: Our early experience with Laparascopic Right hemicolectomy as a safe and oncologically feasible surgical option. We attained comparable surgical results with curative intent.

Keywords: right hemicolectomy, right sided colonic tumors, laparoscopic, curative intent

Procedia PDF Downloads 103
17311 Knowledge and Capabilities of Primary Caregivers in Providing Quality Care for Elderly Patients with Post- Operative Hip Fracture, Songklanagarind Hospital

Authors: Manee Hasap, Mongkolchai Hasap, Tasanee Nasae

Abstract:

The purpose of this study was to evaluate the primary caregivers’ knowledge and capabilities for providing quality care to be hospitalized post-hip fracture surgery elderly patients. The theoretical framework of the study was derived from the concepts of dependent care agency in Orem’s Self-Care theory, and family care provision for the elderly and chronically ill patients. 59 subjects were purposively selected. The subjects were primary caregivers of post-operated hip fracture elderly patients who had been admitted to the Orthopaedic Ward of Songklanagarind Hospital. Demographic data of the caregivers and patients were collected by non-participant observation using the evaluation and recording forms. The reliability of caregivers’ knowledge measurement (0.86) was obtained by KR-20 and that of caregivers’ capabilities for post-operative care evaluation form (0.97) obtained from 2 observers by interrater reliability. The data were analyzed using descriptive statistic, which were frequency, percentage, mean, and standard deviation. The result of this study indicated that elderly patients with post-hip fracture surgery had many pre-discharge self care limitations. Approximately, 75% of the caregivers had knowledge to respond to patient’s essential needs at a high level, while the rest (25%) had this knowledge a moderate level. For observation, 57.63% of the subjects had capabilities in care practice at a moderate level; 28.81% had capabilities in care practice at a high level, while 13.56% had at a low level. The result of this study can be used as basic information for patients and caregivers capabilities developing plan especially, providing patients’ activities, accident surveillance and complications prevention for a good life quality of elderly patients after hip surgery both hospitalization and rehabilitation at home.

Keywords: care givers’ knowledge, care givers’ capabilities, elderly hip fracture patients, patients

Procedia PDF Downloads 529
17310 Comparison of Safety and Efficacy between Thulium Fibre Laser and Holmium YAG Laser for Retrograde Intrarenal Surgery

Authors: Sujeet Poudyal

Abstract:

Introduction: After Holmium:yttrium-aluminum-garnet (Ho: YAG) laser has revolutionized the management of urolithiasis, the introduction of Thulium fibre laser (TFL) has already challenged Ho:YAG laser due to its multiple commendable properties. Nevertheless, there are only few studies comparing TFL and holmium laser in Retrograde Intrarenal Surgery(RIRS). Therefore, this study was carried out to compare the efficacy and safety of thulium fiber laser (TFL) and holmium laser in RIRS. Methods: This prospective comparative study, which included all patients undergoing laser lithotripsy (RIRS) for proximal ureteric calculus and nephrolithiasis from March 2022 to March 2023, consisted of 63 patients in Ho:YAG laser group and 65 patients in TFL group. Stone free rate, operative time, laser utilization time, energy used, and complications were analysed between the two groups. Results: Mean stone size was comparable in TFL (14.23±4.1 mm) and Ho:YAG (13.88±3.28 mm) group, p-0.48. Similarly, mean stone density in TFL (1269±262 HU) was comparable to Ho:YAG (1189±212 HU), p-0.48. There was significant difference in lasing time between TFL (12.69±7.41 mins) and Ho:YAG (20.44±14 mins), p-0.012). TFL group had operative time of 43.47± 16.8 mins which was shorter than Ho:YAG group (58±26.3 mins),p-0.005. Both TFL and Ho:YAG groups had comparable total energy used(11.4±6.2 vs 12±8 respectively, p-0.758). Stone free rate was 87%for TFL, whereas it was 79.5% for Ho:YAG, p-0.25). Two cases of sepsis and one ureteric stricture were encountered in TFL, whereas three cases suffered from sepsis apart from one ureteric stricture in Ho:YAG group, p-0.62). Conclusion: Thulium Fibre Laser has similar efficacy as Holmium: YAG Laser in terms of safety and stone free rate. However, due to better stone ablation rate in TFL, it can become the game changer in management of urolithiasis in the coming days.

Keywords: retrograde intrarenal surgery, thulium fibre laser, holmium:yttrium-aluminum-garnet (ho:yag) laser, nephrolithiasis

Procedia PDF Downloads 45
17309 Work in the Industry of the Future-Investigations of Human-Machine Interactions

Authors: S. Schröder, P. Ennen, T. Langer, S. Müller, M. Shehadeh, M. Haberstroh, F. Hees

Abstract:

Since a bit over a year ago, Festo AG and Co. KG, Festo Didactic SE, robomotion GmbH, the researchers of the Cybernetics-Lab IMA/ZLW and IfU, as well as the Human-Computer Interaction Center at the RWTH Aachen University, have been working together in the focal point of assembly competences to realize different scenarios in the field of human-machine interaction (HMI). In the framework of project ARIZ, questions concerning the future of production within the fourth industrial revolution are dealt with. There are many perspectives of human-robot collaboration that consist Industry 4.0 on an individual, organization and enterprise level, and these will be addressed in ARIZ. The aim of the ARIZ projects is to link AI-Approaches to assembly problems and to implement them as prototypes in demonstrators. To do so, island and flow based production scenarios will be simulated and realized as prototypes. These prototypes will serve as applications of flexible robotics as well as AI-based planning and control of production process. Using the demonstrators, human interaction strategies will be examined with an information system on one hand, and a robotic system on the other. During the tests, prototypes of workspaces that illustrate prospective production work forms will be represented. The human being will remain a central element in future productions and will increasingly be in charge of managerial tasks. Questions thus arise within the overall perspective, primarily concerning the role of humans within these technological revolutions, as well as their ability to act and design respectively to the acceptance of such systems. Roles, such as the 'Trainer' of intelligent systems may become a possibility in such assembly scenarios.

Keywords: human-machine interaction, information technology, island based production, assembly competences

Procedia PDF Downloads 176
17308 MRCP as a Pre-Operative Tool for Predicting Variant Biliary Anatomy in Living Related Liver Donors

Authors: Awais Ahmed, Atif Rana, Haseeb Zia, Maham Jahangir, Rashed Nazir, Faisal Dar

Abstract:

Purpose: Biliary complications represent the most common cause of morbidity in living related liver donor transplantation and detailed preoperative evaluation of biliary anatomic variants is crucial for safe patient selection and improved surgical outcomes. Purpose of this study is to determine the accuracy of preoperative MRCP in predicting biliary variations when compared to intraoperative cholangiography in living related liver donors. Materials and Methods: From 44 potential donors, 40 consecutive living related liver donors (13 females and 28 males) underwent donor hepatectomy at our centre from April 2012 to August 2013. MRCP and IOC of all patients were retrospectively reviewed separately by two radiologists and a transplant surgeon.MRCP was performed on 1.5 Tesla MR magnets using breath-hold heavily T2 weighted radial slab technique. One patient was excluded due to suboptimal MRCP. The accuracy of MRCP for variant biliary anatomy was calculated. Results: MRCP accurately predicted the biliary anatomy in 38 of 39 cases (97 %). Standard biliary anatomy was predicted by MRCP in 25 (64 %) donors (100% sensitivity). Variant biliary anatomy was noted in 14 (36 %) IOCs of which MRCP predicted precise anatomy of 13 variants (93 % sensitivity). The two most common variations were drainage of the RPSD into the LHD (50%) and the triple confluence of the RASD, RPSD and LHD (21%). Conclusion: MRCP is a sensitive imaging tool for precise pre-operative mapping of biliary variations which is critical to surgical decision making in living related liver transplantation.

Keywords: intraoperative cholangiogram, liver transplantation, living related donors, magnetic resonance cholangio-pancreaticogram (MRCP)

Procedia PDF Downloads 364
17307 Use of Dual-Energy CT Post Endovascular Treatment of Cerebral Aneurysm

Authors: Mitchell Stanton

Abstract:

Background: Endovascular management is well established as a mainstay treatment option for cerebral aneurysms. It is also well established that immediate post procedural imaging can be difficult to interpret due to the presence of contrast material. However, through the use of Dual-Energy computed tomography, it has become possible to differentiate contrast extravasation and intracranial haemorrhage. This case illustrates the importance of this technology following endovascular treatment of an unruptured cerebral aneurysm. Case Presentation: A 79-year-old female was found to have an unruptured large intracavernous ICA fusiform aneurysm on CT Brain Angiogram after presenting with acute ophthalmoplegia. This ophthalmoplegia was caused by mass effect from the aneurysm and subsequently the aneurysm was treated with an endovascular flow diverting stent. CT brain was performed post operatively due to a reduced level of consciousness and this showed diffuse subarachnoid hyperdensity of the left hemisphere. The use of Dual-Energy CT allowed accurate differentiation and illustrated diffuse contrast material extravasation, allowing patient to continue on dual-antiplatelets and therapeutic anticoagulation to reduce the risk of ischaemic injury post endovascular stent. Conclusion: Endovascular treatment options for management of intracranial aneurysms are constantly evolving. The use of Dual-Energy CT therefore has an integral role in accurately diagnosing any post-operative complications. Specifically, differentiating between subarachnoid haemorrhage and contrast extravasation is vital in these patients due to the significant consequences to their ongoing management in regards to continuation or cessation of antiplatelets or anticoagulation. With increasing access to this technology, its use should become standard practice in the post-operative investigation of these patients undergoing endovascular treatment.

Keywords: aneurysm, computed tomography, contrast extravasation, dual-energy CT, endovascular, subarachnoid haemorrhage

Procedia PDF Downloads 48
17306 Optimization of Bifurcation Performance on Pneumatic Branched Networks in next Generation Soft Robots

Authors: Van-Thanh Ho, Hyoungsoon Lee, Jaiyoung Ryu

Abstract:

Efficient pressure distribution within soft robotic systems, specifically to the pneumatic artificial muscle (PAM) regions, is essential to minimize energy consumption. This optimization involves adjusting reservoir pressure, pipe diameter, and branching network layout to reduce flow speed and pressure drop while enhancing flow efficiency. The outcome of this optimization is a lightweight power source and reduced mechanical impedance, enabling extended wear and movement. To achieve this, a branching network system was created by combining pipe components and intricate cross-sectional area variations, employing the principle of minimal work based on a complete virtual human exosuit. The results indicate that modifying the cross-sectional area of the branching network, gradually decreasing it, reduces velocity and enhances momentum compensation, preventing flow disturbances at separation regions. These optimized designs achieve uniform velocity distribution (uniformity index > 94%) prior to entering the connection pipe, with a pressure drop of less than 5%. The design must also consider the length-to-diameter ratio for fluid dynamic performance and production cost. This approach can be utilized to create a comprehensive PAM system, integrating well-designed tube networks and complex pneumatic models.

Keywords: pneumatic artificial muscles, pipe networks, pressure drop, compressible turbulent flow, uniformity flow, murray's law

Procedia PDF Downloads 42
17305 Acute Cartilage Defects of the Knee Treated With Chondral Restoration Procedures and Patellofemoral Stabilisation

Authors: John Scanlon, Antony Raymond, Randeep Aujla, Peter D’Alessandro, Satyen Gohil

Abstract:

Background: The incidence of significant acute chondral injuries with patella dislocation is around 10-15%. It is accepted that chondral procedures should only be performed in the presence of joint stability Methods:Patients were identified from surgeon/hospital logs. Patient demographics, lesion size and location, surgical procedure, patient reported outcome measures, post-operative MR imaging, and complications were recorded. PROMs and patient satisfaction was obtained. Results:20 knees (18 patients) were included. Mean age was 18.6 years (range; 11-39), and the mean follow-up was 16.6 months (range; 2-70). The defect locations were the lateral femoral condyle (9/20; 45%), patella (9/20; 45%), medial femoral condyle (1/20; 5%) and the trochlea (1/20; 5%). The mean defect size was 2.6cm2. Twelve knees were treated with cartilage fixation, 5 with microfracture, and 3 with OATS. At follow up, the overall mean Lysholm score was 77.4 (± 17.1), with no chondral regenerative procedure being statistically superior. There was no difference in Lysholm scores between those patients having acute medial patellofemoral ligament reconstruction versus medial soft tissue plication (p=0.59). Five (25%) knees required re-operation (one arthroscopic arthrolysis; one patella chondroplasty; two removal of loose bodies; one implant adjustment). Overall, 90% responded as being satisfied with surgery. Conclusion: Our aggressive pathway to identify and treat acute cartilage defects with early operative intervention and patella stabilisation has shown high rates of satisfaction and Lysholm scores. The full range of chondral restoration options should be considered by surgeons managing these patients.

Keywords: patella dislocation, chondral restoration, knee, patella stabilisation

Procedia PDF Downloads 98
17304 A Leader-Follower Kinematic-Based Control System for a Cable-Driven Hyper-Redundant Manipulator

Authors: Abolfazl Zaraki, Yoshikatsu Hayashi, Harry Thorpe, Vincent Strong, Gisle-Andre Larsen, William Holderbaum

Abstract:

Thanks to the high maneuverability of the cable-driven hyper-redundant manipulators (HRMs), this class of robots has shown a superior capability in highly confined and unstructured space applications. Although the large number of degrees of freedom (DOF) of HRMs enhances the motion flexibility and the robot’s reachability range, it highly increases the complexity of the kinematic configuration which makes the kinematic control problem very challenging or even impossible to solve. This paper presents our current progress achieved on the development of a kinematic-based leader-follower control system which is designed to control not only the robot’s body posture but also to control the trajectory of the robot’s movement in a semi-autonomous manner (the human operator is retained in the robot’s control loop). To obtain the forward kinematic model, the coordinate frames are established by the classical Denavit–Hartenburg (D-H) convention for a hyper-redundant serial manipulator which has a controlled cables-driven mechanism. To solve the inverse kinematics of the robot, unlike the conventional methods, a leader-follower mechanism, based on the sequential inverse kinematic, is followed. Using this mechanism, the inverse kinematic problem is solved for all sequential joints starting from the head joint to the base joint of the robot. To verify the kinematic design and simulate the robot motion, the MATLAB robotic toolbox is used. The simulation result demonstrated the promising capability of the proposed leader-follower control system in controlling the robot motion and trajectory in our confined space application.

Keywords: hyper-redundant robots, kinematic analysis, semi-autonomous control, serial manipulators

Procedia PDF Downloads 137
17303 PID Sliding Mode Control with Sliding Surface Dynamics based Continuous Control Action for Robotic Systems

Authors: Wael M. Elawady, Mohamed F. Asar, Amany M. Sarhan

Abstract:

This paper adopts a continuous sliding mode control scheme for trajectory tracking control of robot manipulators with structured and unstructured uncertain dynamics and external disturbances. In this algorithm, the equivalent control in the conventional sliding mode control is replaced by a PID control action. Moreover, the discontinuous switching control signal is replaced by a continuous proportional-integral (PI) control term such that the implementation of the proposed control algorithm does not require the prior knowledge of the bounds of unknown uncertainties and external disturbances and completely eliminates the chattering phenomenon of the conventional sliding mode control approach. The closed-loop system with the adopted control algorithm has been proved to be globally stable by using Lyapunov stability theory. Numerical simulations using the dynamical model of robot manipulators with modeling uncertainties demonstrate the superiority and effectiveness of the proposed approach in high speed trajectory tracking problems.

Keywords: PID, robot, sliding mode control, uncertainties

Procedia PDF Downloads 471
17302 Results concerning the University: Industry Partnership for a Research Project Implementation (MUROS) in the Romanian Program Star

Authors: Loretta Ichim, Dan Popescu, Grigore Stamatescu

Abstract:

The paper reports the collaboration between a top university from Romania and three companies for the implementation of a research project in a multidisciplinary domain, focusing on the impact and benefits both for the education and industry. The joint activities were developed under the Space Technology and Advanced Research Program (STAR), funded by the Romanian Space Agency (ROSA) for a university-industry partnership. The context was defined by linking the European Space Agency optional programs, with the development and promotion national research, with the educational and industrial capabilities in the aeronautics, security and related areas by increasing the collaboration between academic and industrial entities as well as by realizing high-level scientific production. The project name is Multisensory Robotic System for Aerial Monitoring of Critical Infrastructure Systems (MUROS), which was carried 2013-2016. The project included the University POLITEHNICA of Bucharest (coordinator) and three companies, which manufacture and market unmanned aerial systems. The project had as main objective the development of an integrated system for combined ground wireless sensor networks and UAV monitoring in various application scenarios for critical infrastructure surveillance. This included specific activities related to fundamental and applied research, technology transfer, prototype implementation and result dissemination. The core area of the contributions laid in distributed data processing and communication mechanisms, advanced image processing and embedded system development. Special focus is given by the paper to analyzing the impact the project implementation in the educational process, directly or indirectly, through the faculty members (professors and students) involved in the research team. Three main directions are discussed: a) enabling students to carry out internships at the partner companies, b) handling advanced topics and industry requirements at the master's level, c) experiments and concept validation for doctoral thesis. The impact of the research work (as the educational component) developed by the faculty members on the increasing performances of the companies’ products is highlighted. The collaboration between university and companies was well balanced both for contributions and results. The paper also presents the outcomes of the project which reveals the efficient collaboration between high education and industry: master thesis, doctoral thesis, conference papers, journal papers, technical documentation for technology transfer, prototype, and patent. The experience can provide useful practices of blending research and education within an academia-industry cooperation framework while the lessons learned represent a starting point in debating the new role of advanced research and development performing companies in association with higher education. This partnership, promoted at UE level, has a broad impact beyond the constrained scope of a single project and can develop into long-lasting collaboration while benefiting all stakeholders: students, universities and the surrounding knowledge-based economic and industrial ecosystem. Due to the exchange of experiences between the university (UPB) and the manufacturing company (AFT Design), a new project, SIMUL, under the Bridge Grant Program (Romanian executive agency UEFISCDI) was started (2016 – 2017). This project will continue the educational research for innovation on master and doctoral studies in MUROS thematic (collaborative multi-UAV application for flood detection).

Keywords: education process, multisensory robotic system, research and innovation project, technology transfer, university-industry partnership

Procedia PDF Downloads 208
17301 Teaching the Binary System via Beautiful Facts from the Real Life

Authors: Salem Ben Said

Abstract:

In recent times the decimal number system to which we are accustomed has received serious competition from the binary number system. In this note, an approach is suggested to teaching and learning the binary number system using examples from the real world. More precisely, we will demonstrate the utility of the binary system in describing the optimal strategy to win the Chinese Nim game, and in telegraphy by decoding the hidden message on Perseverance’s Mars parachute written in the language of binary system. Finally, we will answer the question, “why do modern computers prefer the ternary number system instead of the binary system?”. All materials are provided in a format that is conductive to classroom presentation and discussion.

Keywords: binary number system, Nim game, telegraphy, computers prefer the ternary system

Procedia PDF Downloads 151
17300 An Analysis of Machine Translation: Instagram Translation vs Human Translation on the Perspective Translation Quality

Authors: Aulia Fitri

Abstract:

This aims to seek which part of the linguistics with the common mistakes occurred between Instagram translation and human translation. Instagram is a social media account that is widely used by people in the world. Everyone with the Instagram account can consume the captions and pictures that are shared by their friends, celebrity, and public figures across countries. Instagram provides the machine translation under its caption space that will assist users to understand the language of their non-native. The researcher takes samples from an Indonesian public figure whereas the account is followed by many followers. The public figure tries to help her followers from other countries understand her posts by putting up the English version after the Indonesian version. However, the research on Instagram account has not been done yet even though the account is widely used by the worldwide society. There are 20 samples that will be analysed on the perspective of translation quality and linguistics tools. As the MT, Instagram tends to give a literal translation without regarding the topic meant. On the other hand, the human translation tends to exaggerate the translation which leads a different meaning in English. This is an interesting study to discuss when the human nature and robotic-system influence the translation result.

Keywords: human translation, machine translation (MT), translation quality, linguistic tool

Procedia PDF Downloads 280
17299 Management of Obstructive Hydrocephalus Secondary to a Posterior Fossa Tumor in Children: About 24 Cases Operated at the Central Hospital of Army

Authors: Hakim Derradji, M’Hammedi Yousra, Sabrou Abdelmalek, Tabet Nacer

Abstract:

Introduction: This is a retrospective study carried out at the Central Hospital of Army from 2017 to 2022. Its objective is to demonstrate the best surgical method for the management of obstructive hydrocephalus secondary to a posterior fossa tumor in children, in pre, per, and post-operative. Patients and Methods: During this period, 24 children (over 1 year old) were admitted for treatment of the posterior fossa tumor with obstructive secondary hydrocephalus and the majority of whom benefited from VCS followed by surgery and excision, the rest, received after evacuation from other hospital structures, were managed there beforehand with ventriculoperitoneal diversion or external drainage. We found that the way hydrocephalus is managed has implications for subsequent management, hence the need for this study to determine the effectiveness of different surgical procedures used in the treatment of hydrocephalus in these patients. The evaluation is made on the basis of revision rate, complications, survival, and radiological evaluation. Results: 6 patients (25%) received a ventriculoperitoneal shunt (VPD), 15 patients (62%) underwent a ventriculocysternostomy (VCS), and 3 patients (12.5%) received temporary ventricular drainage before or during tumor excision. The post-operative results were almost similar. Nevertheless, a high failure rate (25%) was observed. No deaths are recorded. In total, 75% of children who had a DVP were reoperated. The revision by VCS was performed, in addition to the 4 patients benefiting from a DVP, with one patient having received external drainage, and only one revision of a VCS was recorded. In the two patients who received external drainage, restoration of CSF outflow was observed following tumor resection. Conclusion: VCS is indicated in the first intention in the treatment of hydrocephalus secondary to a posterior fossa tumor, in view of the satisfactory results obtained and the high failure rate in DVP, especially with the presence of metastatic cells in the peritoneum, but can be considered as a second-line treatment.

Keywords: posterior fossa tumor, obstructive hydrocephalus, DVP, VCS

Procedia PDF Downloads 82
17298 Robotic Process Automation in Accounting and Finance Processes: An Impact Assessment of Benefits

Authors: Rafał Szmajser, Katarzyna Świetla, Mariusz Andrzejewski

Abstract:

Robotic process automation (RPA) is a technology of repeatable business processes performed using computer programs, robots that simulate the work of a human being. This approach assumes replacing an existing employee with the use of dedicated software (software robots) to support activities, primarily repeated and uncomplicated, characterized by a low number of exceptions. RPA application is widespread in modern business services, particularly in the areas of Finance, Accounting and Human Resources Management. By utilizing this technology, the effectiveness of operations increases while reducing workload, minimizing possible errors in the process, and as a result, bringing measurable decrease in the cost of providing services. Regardless of how the use of modern information technology is assessed, there are also some doubts as to whether we should replace human activities in the implementation of the automation in business processes. After the initial awe for the new technological concept, a reflection arises: to what extent does the implementation of RPA increase the efficiency of operations or is there a Business Case for implementing it? If the business case is beneficial, in which business processes is the greatest potential for RPA? A closer look at these issues was provided by in this research during which the respondents’ view of the perceived advantages resulting from the use of robotization and automation in financial and accounting processes was verified. As a result of an online survey addressed to over 500 respondents from international companies, 162 complete answers were returned from the most important types of organizations in the modern business services industry, i.e. Business or IT Process Outsourcing (BPO/ITO), Shared Service Centers (SSC), Consulting/Advisory and their customers. Answers were provided by representatives of the positions in their organizations: Members of the Board, Directors, Managers and Experts/Specialists. The structure of the survey allowed the respondents to supplement the survey with additional comments and observations. The results formed the basis for the creation of a business case calculating tangible benefits associated with the implementation of automation in the selected financial processes. The results of the statistical analyses carried out with regard to revenue growth confirmed the correctness of the hypothesis that there is a correlation between job position and the perception of the impact of RPA implementation on individual benefits. Second hypothesis (H2) that: There is a relationship between the kind of company in the business services industry and the reception of the impact of RPA on individual benefits was thus not confirmed. Based results of survey authors performed simulation of business case for implementation of RPA in selected Finance and Accounting Processes. Calculated payback period was diametrically different ranging from 2 months for the Account Payables process with 75% savings and in the extreme case for the process Taxes implementation and maintenance costs exceed the savings resulting from the use of the robot.

Keywords: automation, outsourcing, business process automation, process automation, robotic process automation, RPA, RPA business case, RPA benefits

Procedia PDF Downloads 110
17297 Right Cerebellar Stroke with a Right Vertebral Artery Occlusion Following an Embolization of the Right Glomus Tympanicum Tumor

Authors: Naim Izet Kajtazi

Abstract:

Context: Although rare, glomus tumor (i.e., nonchromaffin chemodectomas and paragan¬gliomas) is the most common middle ear tumor, with female predominance. Pre-operative embolization is often required to devascularize the hypervascular tumor for better surgical outcomes. Process: A 35-year-old female presented with episodes of frequent dizziness, ear fullness, and right ear tinnitus for 12 months. Head imaging revealed a right glomus tympanicum tumor. She underwent pre-operative endovascular embolization of the glomus tympanicum tumor with surgical, cyanoacrylate-based glue. Immediately after the procedure, she developed drowsiness and severe pain in the right temporal region. Further investigations revealed a right cerebellar stroke in the posterior inferior cerebellar artery territory. She was treated with intravenous heparin, followed by one year of oral anticoagulation. With rehabilitation, she significantly recovered from her post embolization stroke. However, the tumor was resected at another institution. Ten years later, follow-up imaging indicated a gradual increase in the size of the glomus jugulare tumor, compressing the nearby critical vascular structures. She subsequently received radiation therapy to treat the residual tumor. Outcome: Currently, she has no neurological deficit, but her mild dizziness, right ear tinnitus, and hearing impairment persist. Relevance: This case highlights the complex nature of these tumors, which often bring challenges to the patients as well as treatment teams. The multi-disciplinary team approach is necessary to tailor the management plan for individual tumors. Although embolization is a safe procedure, careful attention and thoughtful anatomic knowledge regarding dangerous anastomosis are essential to avoid devastating complications. Complications occur due to encountered vessel anomalies and new anastomoses formed during the gluing and changes in hemodynamics.

Keywords: stroke, embolization, MRI brain, cerebral angiogram

Procedia PDF Downloads 44
17296 Robot-Assisted Laparoscopic Surgeries: Current Use in Pediatric Urology Patients

Authors: Rimel Mwamba, Mohan Gundeti

Abstract:

Introduction: The use of robot-assisted laparoscopic surgeries (RALS) has largely increased in recent years, offering faster and safer treatment options for pediatric patients. In the field of urology, RALS has shown a significant advantage over laparoscopic and open surgeries but continues to be controversial in pediatric cases due to limited comprehensive data on its use. Methods: In this review, we aim to summarize the factors associated with RALS use in pediatric cases involving pyeloplasty, ureteral reimplantation, heminephrectomy, and lower urinary tract reconstruction. We used PubMed, EMBASE, and the Cochrane Database of Systematic Reviews to systematically search for literature on the topic. We then critically assessed and compiled data on RALS outcomes, complications, and associated factors. Results: To date, numerous comparative studies have been conducted on pediatric RALS, with only one randomized control trial investigating the nuances of robotic use against standard of care treatments. These robotic approaches have shown promise in post-surgical outcomes for pediatric patients undergoing upper and lower urinary tract reconstruction. Barriers to use still persist, however, showcasing a need to increase access to the technology, refine instruments for pediatric use, address cost barriers, and provide proper training for surgeons. Conclusion: RALS providesan opportunity to improve pediatric patient outcomes for numerous urologic complications. Additional studies are required to better compare the use of RALS with current standard practices. Due to the difficult nature of conducting randomized control trials, additional prospective observational studies are needed.

Keywords: pediatric urology, robot-assisted laparoscopic surgeries (RALS), pyeloplasty, ureteral reimplantation, heminephrectomy, and lower urinary tract reconstruction

Procedia PDF Downloads 69
17295 Laparoscopic Resection Shows Comparable Outcomes to Open Thoracotomy for Thoracoabdominal Neuroblastomas: A Meta-Analysis and Systematic Review

Authors: Peter J. Fusco, Dave M. Mathew, Chris Mathew, Kenneth H. Levy, Kathryn S. Varghese, Stephanie Salazar-Restrepo, Serena M. Mathew, Sofia Khaja, Eamon Vega, Mia Polizzi, Alyssa Mullane, Adham Ahmed

Abstract:

Background: Laparoscopic (LS) removal of neuroblastomas in children has been reported to offer favorable outcomes compared to the conventional open thoracotomy (OT) procedure. Critical perioperative measures such as blood loss, operative time, length of stay, and time to postoperative chemotherapy have all supported laparoscopic use rather than its more invasive counterpart. Herein, a pairwise meta-analysis was performed comparing perioperative outcomes between LS and OT in thoracoabdominal neuroblastoma cases. Methods: A comprehensive literature search was performed on PubMed, Ovid EMBASE, and Scopus databases to identify studies comparing the outcomes of pediatric patients with thoracoabdominal neuroblastomas undergoing resection via OT or LS. After deduplication, 4,227 studies were identified and subjected to initial title screening with exclusion and inclusion criteria to ensure relevance. When studies contained overlapping cohorts, only the larger series were included. Primary outcomes include estimated blood loss (EBL), hospital length of stay (LOS), and mortality, while secondary outcomes were tumor recurrence, post-operative complications, and operation length. The “meta” and “metafor” packages were used in R, version 4.0.2, to pool risk ratios (RR) or standardized mean differences (SMD) in addition to their 95% confidence intervals in the random effects model via the Mantel-Haenszel method. Heterogeneity between studies was assessed using the I² test, while publication bias was assessed via funnel plot. Results: The pooled analysis included 209 patients from 5 studies (141 OT, 68 LS). Of the included studies, 2 originated from the United States, 1 from Toronto, 1 from China, and 1was from a Japanese center. Mean age between study cohorts ranged from 2.4 to 5.3 years old, with female patients occupying between 30.8% to 50% of the study populations. No statistically significant difference was found between the two groups for LOS (SMD -1.02; p=0.083), mortality (RR 0.30; p=0.251), recurrence(RR 0.31; p=0.162), post-operative complications (RR 0.73; p=0.732), or operation length (SMD -0.07; p=0.648). Of note, LS appeared to be protective in the analysis for EBL, although it did not reach statistical significance (SMD -0.4174; p= 0.051). Conclusion: Despite promising literature assessing LS removal of pediatric neuroblastomas, results showed it was non-superior to OT for any explored perioperative outcomes. Given the limited comparative data on the subject, it is evident that randomized trials are necessary to further the efficacy of the conclusions reached.

Keywords: laparoscopy, neuroblastoma, thoracoabdominal, thoracotomy

Procedia PDF Downloads 101
17294 Botulinum Toxin type A for Lower Limb Lengthening and Deformity Correction: A Systematic Review and Meta-analysis

Authors: Jawaher F. Alsharef, Abdullah A. Ghaddaf, Mohammed S. Alomari, Abdullah A. Al Qurashi, Ahmed S. Abdulhamid, Mohammed S. Alshehri, Majed Alosaimi

Abstract:

Botulinum toxin type A (BTX-A) is the most popular therapeutic agent for muscle relaxation and pain control. Lately, BTX-A injection received great interest as a part of multimodal pain management for lower limb lengthening and deformity correction. This systematic review aimed to determine the role of BTX-A injection in pain management for during lower limb lengthening and/or deformity correction. We searched Medline, Embase, and CENTRAL. We included randomized controlled trials (RCTs) that compared the BTX-A injection to placebo for individuals undergoing lower limb lengthening and/or deformity correction. We sought to evaluate the following outcomes: pain on visual analogue scale (VAS), range of motion parameters, average opioid consumption, and adverse events. The standardized mean difference (SMD) was used to represent continuous outcomes while risk ratio (RR) was used to represent dichotomous outcomes. A total of 4 RCTs that enrolled 257 participants (337 limbs) deemed eligible. Adjuvant BTX-A injection showed a significant reduction in post-operative pain compared to placebo (SMD=–0.28, 95% CI –0.53 to –0.04). No difference was found between BTX-A injection and placebo in terms of range of motion parameters, average opioid consumption, or adverse events after surgical limb lengthening and/or deformity correction (RR= 0.77, 95% CI –0.58 to 1.03). Conclusions: Adjuvant BTX-A injection conferred a discernible reduction in post-operative pain during surgical limb lengthening and/or deformity without increasing the risk of adverse events.

Keywords: botulinum toxin type A, limb lengthening, distraction osteogenesis, deformity correction, pain management

Procedia PDF Downloads 114
17293 Modern Cardiac Surgical Outcomes in Nonagenarians: A Multicentre Retrospective Observational Study

Authors: Laurence Weinberg, Dominic Walpole, Dong-Kyu Lee, Michael D’Silva, Jian W. Chan, Lachlan F. Miles, Bradley Carp, Adam Wells, Tuck S. Ngun, Siven Seevanayagam, George Matalanis, Ziauddin Ansari, Rinaldo Bellomo, Michael Yii

Abstract:

Background: There have been multiple recent advancements in the selection, optimization and management of cardiac surgical patients. However, there is limited data regarding the outcomes of nonagenarians undergoing cardiac surgery, despite this vulnerable cohort increasingly receiving these interventions. This study describes the patient characteristics, management and outcomes of a group of nonagenarians undergoing cardiac surgery in the context of contemporary peri-operative care. Methods: A retrospective observational study was conducted of patients 90 to 99 years of age (i.e., nonagenarians) who had undergone cardiac surgery requiring a classic median sternotomy (i.e., open-heart surgery). All operative indications were included. Patients who underwent minimally invasive surgery, transcatheter aortic valve implantation and thoracic aorta surgery were excluded. Data were collected from four hospitals in Victoria, Australia, over an 8-year period (January 2012 – December 2019). The primary objective was to assess six-month mortality in nonagenarians undergoing open-heart surgery and to evaluate the incidence and severity of postoperative complications using the Clavien-Dindo classification system. The secondary objective was to provide a detailed description of the characteristics and peri-operative management of this group. Results: A total of 12,358 adult patients underwent cardiac surgery at the study centers during the observation period, of whom 18 nonagenarians (0.15%) fulfilled the inclusion criteria. The median (IQR) [min-max] age was 91 years (90.0:91.8) [90-94] and 14 patients (78%) were men. Cardiovascular comorbidities, polypharmacy and frailty, were common. The median (IQR) predicted in-hospital mortality by EuroSCORE II was 6.1% (4.1-14.5). All patients were optimized preoperatively by a multidisciplinary team of surgeons, cardiologists, geriatricians and anesthetists. All index surgeries were performed on cardiopulmonary bypass. Isolated coronary artery bypass grafting (CABG) and CABG with aortic valve replacement were the most common surgeries being performed in four and five patients, respectively. Half the study group underwent surgery involving two or more major procedures (e.g. CABG and valve replacement). Surgery was undertaken emergently in 44% of patients. All patients except one experienced at least one postoperative complication. The most common complications were acute kidney injury (72%), new atrial fibrillation (44%) and delirium (39%). The highest Clavien-Dindo complication grade was IIIb occurring once each in three patients. Clavien-Dindo grade IIIa complications occurred in only one patient. The median (IQR) postoperative length of stay was 11.6 days (9.8:17.6). One patient was discharged home and all others to an inpatient rehabilitation facility. Three patients had an unplanned readmission within 30 days of discharge. All patients had follow-up to at least six months after surgery and mortality over this period was zero. The median (IQR) duration of follow-up was 11.3 months (6.0:26.4) and there were no cases of mortality observed within the available follow-up records. Conclusion: In this group of nonagenarians undergoing cardiac surgery, postoperative six-month mortality was zero. Complications were common but generally of low severity. These findings support carefully selected nonagenarian patients being offered cardiac surgery in the context of contemporary, multidisciplinary perioperative care. Further, studies are needed to assess longer-term mortality and functional and quality of life outcomes in this vulnerable surgical cohort.

Keywords: cardiac surgery, mortality, nonagenarians, postoperative complications

Procedia PDF Downloads 91
17292 Laser Registration and Supervisory Control of neuroArm Robotic Surgical System

Authors: Hamidreza Hoshyarmanesh, Hosein Madieh, Sanju Lama, Yaser Maddahi, Garnette R. Sutherland, Kourosh Zareinia

Abstract:

This paper illustrates the concept of an algorithm to register specified markers on the neuroArm surgical manipulators, an image-guided MR-compatible tele-operated robot for microsurgery and stereotaxy. Two range-finding algorithms, namely time-of-flight and phase-shift, are evaluated for registration and supervisory control. The time-of-flight approach is implemented in a semi-field experiment to determine the precise position of a tiny retro-reflective moving object. The moving object simulates a surgical tool tip. The tool is a target that would be connected to the neuroArm end-effector during surgery inside the magnet bore of the MR imaging system. In order to apply flight approach, a 905-nm pulsed laser diode and an avalanche photodiode are utilized as the transmitter and receiver, respectively. For the experiment, a high frequency time to digital converter was designed using a field-programmable gate arrays. In the phase-shift approach, a continuous green laser beam with a wavelength of 530 nm was used as the transmitter. Results showed that a positioning error of 0.1 mm occurred when the scanner-target point distance was set in the range of 2.5 to 3 meters. The effectiveness of this non-contact approach exhibited that the method could be employed as an alternative for conventional mechanical registration arm. Furthermore, the approach is not limited by physical contact and extension of joint angles.

Keywords: 3D laser scanner, intraoperative MR imaging, neuroArm, real time registration, robot-assisted surgery, supervisory control

Procedia PDF Downloads 257
17291 An Autonomous Space Debris-Removal System for Effective Space Missions

Authors: Shriya Chawla, Vinayak Malhotra

Abstract:

Space exploration has noted an exponential rise in the past two decades. The world has started probing the alternatives for efficient and resourceful sustenance along with utilization of advanced technology viz., satellites on earth. Space propulsion forms the core of space exploration. Of all the issues encountered, space debris has increasingly threatened the space exploration and propulsion. The efforts have resulted in the presence of disastrous space debris fragments orbiting the earth at speeds up to several kilometres per hour. Debris are well known as a potential damage to the future missions with immense loss of resources, mankind, and huge amount of money is invested in active research on them. Appreciable work had been done in the past relating to active space debris-removal technologies such as harpoon, net, drag sail. The primary emphasis is laid on confined removal. In recently, remove debris spacecraft was used for servicing and capturing cargo ships. Airbus designed and planned the debris-catching net experiment, aboard the spacecraft. The spacecraft represents largest payload deployed from the space station. However, the magnitude of the issue suggests that active space debris-removal technologies, such as harpoons and nets, still would not be enough. Thus, necessitating the need for better and operative space debris removal system. Techniques based on diverting the path of debris or the spacecraft to avert damage have turned out minimal usage owing to limited predictions. Present work focuses on an active hybrid space debris removal system. The work is motivated by the need to have safer and efficient space missions. The specific objectives of the work are 1) to thoroughly analyse the existing and conventional debris removal techniques, their working, effectiveness and limitations under varying conditions, 2) to understand the role of key controlling parameters in coupled operation of debris capturing and removal. The system represents the utilization of the latest autonomous technology available with an adaptable structural design for operations under varying conditions. The design covers advantages of most of the existing technologies while removing the disadvantages. The system is likely to enhance the probability of effective space debris removal. At present, systematic theoretical study is being carried out to thoroughly observe the effects of pseudo-random debris occurrences and to originate an optimal design with much better features and control.

Keywords: space exploration, debris removal, space crafts, space accidents

Procedia PDF Downloads 136