Search results for: robotic cardiac surgery
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1674

Search results for: robotic cardiac surgery

1644 The Robotic Intervention in the Tourism Experience: The Customer Journey’s Touchpoints, Context, and Qualities

Authors: Aikaterini Manthiou, Phil Klaus, Kafia Ayadi

Abstract:

Tourism research has shown a growing need to comprehend the robotic tourism experience’s meaning and foundations while also offering guidance regarding future discussions and research. This paper aims to analyze the robotic tourism experience based on the basis of De Keyser et al.’s (2020) conceptualization. In order to develop three theoretical propositions, we explore the robotic tourism experience by means of the three building blocks: touchpoints, context, and qualities. The three building blocks should not be examined in isolation but as a system of interplaying factors impacting the customer journey and customer experience. The study discusses the theoretical and practical implications of these impacts, as well as providing future research directions.

Keywords: robotic tourism experience, robot, touchpoints, context, qualities

Procedia PDF Downloads 176
1643 Robotic Arm Control with Neural Networks Using Genetic Algorithm Optimization Approach

Authors: Arbnor Pajaziti, Hasan Cana

Abstract:

In this paper, the structural genetic algorithm is used to optimize the neural network to control the joint movements of robotic arm. The robotic arm has also been modeled in 3D and simulated in real-time in MATLAB. It is found that Neural Networks provide a simple and effective way to control the robot tasks. Computer simulation examples are given to illustrate the significance of this method. By combining Genetic Algorithm optimization method and Neural Networks for the given robotic arm with 5 D.O.F. the obtained the results shown that the base joint movements overshooting time without controller was about 0.5 seconds, while with Neural Network controller (optimized with Genetic Algorithm) was about 0.2 seconds, and the population size of 150 gave best results.

Keywords: robotic arm, neural network, genetic algorithm, optimization

Procedia PDF Downloads 485
1642 Advanced Techniques in Robotic Mitral Valve Repair

Authors: Abraham J. Rizkalla, Tristan D. Yan

Abstract:

Purpose: Durable mitral valve repair is preferred to a replacement, avoiding the need for anticoagulation or re-intervention, with a reduced risk of endocarditis. Robotic mitral repair has been gaining favour globally as a safe, effective, and reproducible method of minimally invasive valve repair. In this work, we showcase the use of the Davinci© Xi robotic platform to perform several advanced techniques, working synergistically to achieve successful mitral repair in advanced mitral disease. Techniques: We present the case of a Barlow type mitral valve disease with a tall and redundant posterior leaflet resulting in severe mitral regurgitation and systolic anterior motion. Firstly, quadrangular resection of P2 is performed to remove the excess and redundant leaflet. Secondly, a sliding leaflet plasty of P1 and P3 is used to reconstruct the posterior leaflet. To anchor the newly formed posterior leaflet to the papillary muscle, CV-4 Goretex neochordae are fashioned using the innovative string, ruler, and bulldog technique. Finally, mitral valve annuloplasty and closure of a patent foramen ovale complete the repair. Results: There was no significant residual mitral regurgitation and complete resolution of the systolic anterior motion of the mitral valve on post operative transoesophageal echocardiography. Conclusion: This work highlights the robotic approach to complex repair techniques for advanced mitral valve disease. Familiarity with resection and sliding plasty, neochord implantation, and annuloplasty allows the modern cardiac surgeon to achieve a minimally-invasive and durable mitral valve repair when faced with complex mitral valve pathology.

Keywords: robotic mitral valve repair, Barlow's valve, sliding plasty, neochord, annuloplasty, quadrangular resection

Procedia PDF Downloads 50
1641 Multi-Tooled Robotic Hand for Tele-Operation of Explosive Devices

Authors: Faik Derya Ince, Ugur Topgul, Alp Gunay, Can Bayoglu, Dante J. Dorantes-Gonzalez

Abstract:

Explosive attacks are arguably the most lethal threat that may occur in terrorist attacks. In order to counteract this issue, explosive ordnance disposal operators put their lives on the line to dispose of a possible improvised explosive device. Robots can make the disposal process more accurately and saving human lives. For this purpose, there is a demand for more accurate and dexterous manipulating robotic hands that can be teleoperated from a distance. The aim of this project is to design a robotic hand that contains two active and two passive DOF for each finger, as well as a minimum set of tools for mechanical cutting and screw driving within the same robotic hand. Both hand and toolset, are teleoperated from a distance from a haptic robotic glove in order to manipulate dangerous objects such as improvised explosive devices. SolidWorks® Computer-Aided Design, computerized dynamic simulation, and MATLAB® kinematic and static analysis were used for the robotic hand and toolset design. Novel, dexterous and robust solutions for the fingers were obtained, and six servo motors are used in total to remotely control the multi-tooled robotic hand. This project is still undergoing and presents currents results. Future research steps are also presented.

Keywords: Explosive Manipulation, Robotic Hand, Tele-Operation, Tool Integration

Procedia PDF Downloads 113
1640 IT-Based Global Healthcare Delivery System: An Alternative Global Healthcare Delivery System

Authors: Arvind Aggarwal

Abstract:

We have developed a comprehensive global healthcare delivery System based on information technology. It has medical consultation system where a virtual consultant can give medical consultation to the patients and Doctors at the digital medical centre after reviewing the patient’s EMR file consisting of patient’s history, investigations in the voice, images and data format. The system has the surgical operation system too, where a remote robotic consultant can conduct surgery at the robotic surgical centre. The instant speech and text translation is incorporated in the software where the patient’s speech and text (language) can be translated into the consultant’s language and vice versa. A consultant of any specialty (surgeon or Physician) based in any country can provide instant health care consultation, to any patient in any country without loss of time. Robotic surgeons based in any country in a tertiary care hospital can perform remote robotic surgery, through patient friendly telemedicine and tele-surgical centres. The patient EMR, financial data and data of all the consultants and robotic surgeons shall be stored in cloud. It is a complete comprehensive business model with healthcare medical and surgical delivery system. The whole system is self-financing and can be implemented in any country. The entire system uses paperless, filmless techniques. This eliminates the use of all consumables thereby reduces substantial cost which is incurred by consumables. The consultants receive virtual patients, in the form of EMR, thus the consultant saves time and expense to travel to the hospital to see the patients. The consultant gets electronic file ready for reporting & diagnosis. Hence time spent on the physical examination of the patient is saved, the consultant can, therefore, spend quality time in studying the EMR/virtual patient and give his instant advice. The time consumed per patient is reduced and therefore can see more number of patients, the cost of the consultation per patients is therefore reduced. The additional productivity of the consultants can be channelized to serve rural patients devoid of doctors.

Keywords: e-health, telemedicine, telecare, IT-based healthcare

Procedia PDF Downloads 150
1639 Component Interface Formalization in Robotic Systems

Authors: Anton Hristozov, Eric Matson, Eric Dietz, Marcus Rogers

Abstract:

Components are heavily used in many software systems, including robotics systems. The growth of sophistication and diversity of new capabilities for robotic systems presents new challenges to their architectures. Their complexity is growing exponentially with the advent of AI, smart sensors, and the complex tasks they have to accomplish. Such complexity requires a more rigorous approach to the creation, use, and interoperability of software components. The issue is exacerbated because robotic systems are becoming more and more reliant on third-party components for certain functions. In order to achieve this kind of interoperability, including dynamic component replacement, we need a way to standardize their interfaces. A formal approach is desperately needed to specify what an interface of a robotic software component should contain. This study performs an analysis of the issue and presents a universal and generic approach to standardizing component interfaces for robotic systems. Our approach is inspired by well-established robotic architectures such as ROS, PX4, and Ardupilot. The study is also applicable to other software systems that share similar characteristics with robotic systems. We consider the use of JSON or Domain Specific Languages (DSL) development with tools such as Antlr and automatic code and configuration file generation for frameworks such as ROS and PX4. A case study with ROS2 is presented as a proof of concept for the proposed methodology.

Keywords: CPS, robots, software architecture, interface, ROS, autopilot

Procedia PDF Downloads 60
1638 Multi-Robotic Partial Disassembly Line Balancing with Robotic Efficiency Difference via HNSGA-II

Authors: Tao Yin, Zeqiang Zhang, Wei Liang, Yanqing Zeng, Yu Zhang

Abstract:

To accelerate the remanufacturing process of electronic waste products, this study designs a partial disassembly line with the multi-robotic station to effectively dispose of excessive wastes. The multi-robotic partial disassembly line is a technical upgrade to the existing manual disassembly line. Balancing optimization can make the disassembly line smoother and more efficient. For partial disassembly line balancing with the multi-robotic station (PDLBMRS), a mixed-integer programming model (MIPM) considering the robotic efficiency differences is established to minimize cycle time, energy consumption and hazard index and to calculate their optimal global values. Besides, an enhanced NSGA-II algorithm (HNSGA-II) is proposed to optimize PDLBMRS efficiently. Finally, MIPM and HNSGA-II are applied to an actual mixed disassembly case of two types of computers, the comparison of the results solved by GUROBI and HNSGA-II verifies the correctness of the model and excellent performance of the algorithm, and the obtained Pareto solution set provides multiple options for decision-makers.

Keywords: waste disposal, disassembly line balancing, multi-robot station, robotic efficiency difference, HNSGA-II

Procedia PDF Downloads 191
1637 The Impact of Centralisation on Radical Prostatectomy Outcomes: Our Outcomes

Authors: Jemini Vyas, Oluwatobi Adeyoe, Jenny Branagan, Chandran Tanabalan, John Beatty, Aakash Pai

Abstract:

Introduction: The development of robotic surgery has accelerated centralisation to tertiary centres, where robotic radical prostatectomy (RP) is offered. The purpose of concentrating treatment in high volume specialist centres is to improve the quality of care and patient outcomes. The aim of this study was to assess the impact on clinical outcomes of centralisation for locally diagnosed patients undergoing RP. Methods: Clinical outcomes for 169 consecutive laparoscopic & open RP pre-centralisation were retrospectively compared with 50 consecutive robotic RP conducted over a similar period post-centralisation. Preoperative risk stratification and time to surgery were collected. Perioperative outcomes, including length of stay (LOS) and complications, were collated. Post-operative outcomes, including erectile dysfunction (ED), biochemical recurrence (BCR), and urinary continence, were assessed. Results: Preoperative risk stratification showed no difference between the two groups. The median time from diagnosis to treatment was similar between the two groups (pre-centralisation, 121 days, post-centralisation, 117 days). The mean length of stay (pre-centralisation, 2.1 days, post-centralisation, 1.6 days) showed no significant difference (p=0.073). Proportion of overall complications (pre-centralisation, 11.4%, post-centralisation, 8.7%) and complications, above Clavien-Dindo 2, were similar between the two groups (pre-centralisation1.2%, post-centralisation 2.2%). Post operative functional parameters, including continence and ED, were comparable. Five-year BCR free rate was 78% for the pre-centralisation group and 79% for the post centralisation group. Conclusion: For our cohort of patients, clinical outcomes have remained static during centralisation. It is imperative that centralisation is accompanied by increased capacity, streamlining of pathways, and training to ensure that improved quality of care is achieved. Our institution has newly acquired a robot, and prospectively studying this data may support the reversal of centralisation for RP surgery.

Keywords: prostate, cancer, prostatectomy, clinical

Procedia PDF Downloads 67
1636 Nurse-Identified Barriers and Facilitators to Delivering End-of-Life Care in a Cardiac Intensive Care Unit: A Qualitative Study

Authors: Elena Ivany, Leanne Aitken

Abstract:

Little is known about the delivery of end-of-life care in cardiac intensive care unit (CICU) settings. The aims of this study were to highlight the nurse-identified barriers and facilitators to delivering end-of-life care in the CICU, and to identify whether any of the barriers and/or facilitators are specific to the CICU setting. This was an exploratory qualitative study utilizing semi-structured individual interviews as the data collection method and inductive thematic analysis to structure the data. Six CICU nurses took part in the study. Five key themes were identified, each theme including both barriers and facilitators. The five key themes are as follows: patient-centered care, emotional challenges, reaching concordance, nursing contribution and the surgical intensive care unit.

Keywords: end-of-life, cardiovascular disease, cardiac surgery, critical care

Procedia PDF Downloads 218
1635 Bioarm, a Prothesis without Surgery

Authors: J. Sagouis, A. Chamel, E. Carre, C. Casasreales, G. Rudnik, M. Cerdan

Abstract:

Robotics provides answers to amputees. The most expensive solutions surgically connect the prosthesis to nerve endings. There are also several types of non-invasive technologies that recover nerve messages passing through the muscles. After analyzing these messages, myoelectric prostheses perform the desired movement. The main goal is to avoid all surgeries, which can be heavy and offer cheaper alternatives. For an amputee, we use valid muscles to recover the electrical signal involved in a muscle movement. EMG sensors placed on the muscle allows us to measure a potential difference, which our program transforms into control for a robotic arm with two degrees of freedom. We have shown the feasibility of non-invasive prostheses with two degrees of freedom. Signal analysis and an increase in degrees of freedom is still being improved.

Keywords: prosthesis, electromyography (EMG), robotic arm, nerve message

Procedia PDF Downloads 230
1634 Calculation the Left Ventricle Wall Radial Strain and Radial SR Using Tagged Magnetic Resonance Imaging Data (tMRI)

Authors: Mohammed Alenezy

Abstract:

The function of cardiac motion can be used as an indicator of the heart abnormality by evaluating longitudinal, circumferential, and Radial Strain of the left ventricle. In this paper, the Radial Strain and SR is studied using tagged MRI (tMRI) data during the cardiac cycle on the mid-ventricle level of the left ventricle. Materials and methods: The short-axis view of the left ventricle of five healthy human (three males and two females) and four healthy male rats were imaged using tagged magnetic resonance imaging (tMRI) technique covering the whole cardiac cycle on the mid-ventricle level. Images were processed using Image J software to calculate the left ventricle wall Radial Strain and radial SR. The left ventricle Radial Strain and radial SR were calculated at the mid-ventricular level during the cardiac cycle. The peak Radial Strain for the human and rat heart was 40.7±1.44, and 46.8±0.68 respectively, and it occurs at 40% of the cardiac cycle for both human and rat heart. The peak diastolic and systolic radial SR for human heart was -1.78 s-1 ± 0.02 s-1 and 1.10±0.08 s-1 respectively, while for rat heart it was -5.16± 0.23s-1 and 4.25±0.02 s-1 respectively. Conclusion: This results show the ability of the tMRI data to characterize the cardiac motion during the cardiac cycle including diastolic and systolic phases which can be used as an indicator of the cardiac dysfunction by estimating the left ventricle Radial Strain and radial SR at different locations of the cardiac tissue. This study approves the validity of the tagged MRI data to describe accurately the cardiac radial motion.

Keywords: left ventricle, radial strain, tagged MRI, cardiac cycle

Procedia PDF Downloads 462
1633 The Estimation of Human Vital Signs Complexity

Authors: L. Bikulciene, E. Venskaityte, G. Jarusevicius

Abstract:

Non-stationary and nonlinear signals generated by living complex systems defy traditional mechanistic approaches, which are based on homeostasis. Previous our studies have shown that the evaluation of the interactions of physiological signals by using special analysis methods is suitable for observation of physiological processes. It is demonstrated the possibility of using deep physiological model, based interpretation of the changes of the human body’s functional states combined with an application of the analytical method based on matrix theory for the physiological signals analysis, which was applied on high risk cardiac patients. It is shown that evaluation of cardiac signals interactions show peculiar for each individual functional changes at the onset of hemodynamic restoration procedure. Therefore we suggest that the alterations of functional state of the body, after patients overcome surgery can be complemented by the data received from the suggested approach of the evaluation of functional variables interactions.

Keywords: cardiac diseases, complex systems theory, ECG analysis, matrix analysis

Procedia PDF Downloads 316
1632 Automatic LV Segmentation with K-means Clustering and Graph Searching on Cardiac MRI

Authors: Hae-Yeoun Lee

Abstract:

Quantification of cardiac function is performed by calculating blood volume and ejection fraction in routine clinical practice. However, these works have been performed by manual contouring,which requires computational costs and varies on the observer. In this paper, an automatic left ventricle segmentation algorithm on cardiac magnetic resonance images (MRI) is presented. Using knowledge on cardiac MRI, a K-mean clustering technique is applied to segment blood region on a coil-sensitivity corrected image. Then, a graph searching technique is used to correct segmentation errors from coil distortion and noises. Finally, blood volume and ejection fraction are calculated. Using cardiac MRI from 15 subjects, the presented algorithm is tested and compared with manual contouring by experts to show outstanding performance.

Keywords: cardiac MRI, graph searching, left ventricle segmentation, K-means clustering

Procedia PDF Downloads 381
1631 Design and Fabrication of a Programmable Stiffness-Sensitive Gripper for Object Handling

Authors: Mehdi Modabberifar, Sanaz Jabary, Mojtaba Ghodsi

Abstract:

Stiffness sensing is an important issue in medical diagnostic, robotics surgery, safe handling, and safe grasping of objects in production lines. Detecting and obtaining the characteristics in dwelling lumps embedded in a soft tissue and safe removing and handling of detected lumps is needed in surgery. Also in industry, grasping and handling an object without damaging in a place where it is not possible to access a human operator is very important. In this paper, a method for object handling is presented. It is based on the use of an intelligent gripper to detect the object stiffness and then setting a programmable force for grasping the object to move it. The main components of this system includes sensors (sensors for measuring force and displacement), electrical (electrical and electronic circuits, tactile data processing and force control system), mechanical (gripper mechanism and driving system for the gripper) and the display unit. The system uses a rotary potentiometer for measuring gripper displacement. A microcontroller using the feedback received by the load cell, mounted on the finger of the gripper, calculates the amount of stiffness, and then commands the gripper motor to apply a certain force on the object. Results of Experiments on some samples with different stiffness show that the gripper works successfully. The gripper can be used in haptic interfaces or robotic systems used for object handling.

Keywords: gripper, haptic, stiffness, robotic

Procedia PDF Downloads 329
1630 Optimizing Pick and Place Operations in a Simulated Work Cell for Deformable 3D Objects

Authors: Troels Bo Jørgensen, Preben Hagh Strunge Holm, Henrik Gordon Petersen, Norbert Kruger

Abstract:

This paper presents a simulation framework for using machine learning techniques to determine robust robotic motions for handling deformable objects. The main focus is on applications in the meat sector, which mainly handle three-dimensional objects. In order to optimize the robotic handling, the robot motions have been parameterized in terms of grasp points, robot trajectory and robot speed. The motions are evaluated based on a dynamic simulation environment for robotic control of deformable objects. The evaluation indicates certain parameter setups, which produce robust motions in the simulated environment, and based on a visual analysis indicate satisfactory solutions for a real world system.

Keywords: deformable objects, robotic manipulation, simulation, real world system

Procedia PDF Downloads 255
1629 Exploring the Effectiveness of Robotic Companions Through the Use of Symbiotic Autonomous Plant Care Robots

Authors: Angelos Kaminis, Dakotah Stirnweis

Abstract:

Advances in robotic technology have driven the development of improved robotic companions in the last couple decades. However, commercially available robotic companions lack the ability to create an emotional connection with their user. By developing a companion robot that has a symbiotic relationship with a plant, an element of co-dependency is introduced into the human companion robot dynamic. This companion robot, while theoretically capable of providing most of the plant’s needs, still requires human interaction for watering, moving obstacles, and solar panel cleaning. To facilitate the interaction between human and robot, the robot is capable of limited auditory and visual communication to help express its and the plant’s needs. This paper seeks to fully describe the Autonomous Plant Care Robot system and its symbiotic relationship with its botanical ward and the plant and robot’s dependent relationship with their owner.

Keywords: symbiotic, robotics, autonomous, plant-care, companion

Procedia PDF Downloads 115
1628 An Assistive Robotic Arm for Defence and Rescue Application

Authors: J. Harrison Kurunathan, R. Jayaparvathy

Abstract:

"Assistive Robotics" is the field that deals with the study of robots that helps in human motion and also empowers human abilities by interfacing the robotic systems to be manipulated by human motion. The proposed model is a robotic arm that works as a haptic interface on the basis on accelerometers and DC motors that will function with respect to the movement of the human muscle. The proposed model would effectively work as a haptic interface that would reduce human effort in the field of defense and rescue. This can be used in very critical conditions like fire accidents to avoid causalities.

Keywords: accelerometers, haptic interface, servo motors, signal processing

Procedia PDF Downloads 365
1627 Optimization of Robot Motion Planning Using Biogeography Based Optimization (Bbo)

Authors: Jaber Nikpouri, Arsalan Amralizadeh

Abstract:

In robotics manipulators, the trajectory should be optimum, thus the torque of the robot can be minimized in order to save power. This paper includes an optimal path planning scheme for a robotic manipulator. Recently, techniques based on metaheuristics of natural computing, mainly evolutionary algorithms (EA), have been successfully applied to a large number of robotic applications. In this paper, the improved BBO algorithm is used to minimize the objective function in the presence of different obstacles. The simulation represents that the proposed optimal path planning method has satisfactory performance.

Keywords: biogeography-based optimization, path planning, obstacle detection, robotic manipulator

Procedia PDF Downloads 268
1626 Impact of Pediatric Cardiac Rehabilitation on the Physical Condition of Children with Congenital Heart Defects

Authors: Hady Atef Labib

Abstract:

Pediatric cardiac rehabilitation has the potential to benefit many children with congenital heart defects (CHD). Instead of excellent surgical results most of children usually present with a depression of physical condition so early rehabilitation program is recommended to avoid that decline in physical tolerance and prevent any post surgical complications. Unfortunately, the limited experience with and availability of these programs has caused the benefits of cardiac rehabilitation to be unavailable to most children with CHD. Therefore, it is recommended to study that field in more detail and apply it on wider scale.

Keywords: pediatric cardiac rehabilitation, congenital heart disease, quality of life, pediatric

Procedia PDF Downloads 344
1625 Quality Assurance in Cardiac Disorder Detection Images

Authors: Anam Naveed, Asma Andleeb, Mehreen Sirshar

Abstract:

In the article, Image processing techniques have been applied on cardiac images for enhancing the image quality. Two types of methodologies considers for survey, invasive techniques and non-invasive techniques. Different image processes for improvement of cardiac image quality and reduce the amount of radiation exposure for invasive techniques are explored. Different image processing algorithms for enhancing the noninvasive cardiac image qualities are described. Beside these two methodologies, third methodology has applied on live streaming of heart rate on ECG window for extracting necessary information, removing noise and enhancing quality. Sensitivity analyses have been carried out to investigate the impacts of cardiac images for diagnosis of cardiac arteries disease and how the enhancement on images will help the cardiologist to diagnoses disease. The paper evaluates strengths and weaknesses of different techniques applied for improved the image quality and draw a conclusion. Some specific limitations must be considered for whole survey, like the patient heart beat must be 70-75 beats/minute while doing the angiography, similarly patient weight and exposure radiation amount has some limitation.

Keywords: cardiac images, CT angiography, critical analysis, exposure radiation, invasive techniques, invasive techniques, non-invasive techniques

Procedia PDF Downloads 317
1624 A Robotic Cube to Preschool Children for Acquiring the Mathematical and Colours Concepts

Authors: Ahmed Amin Mousa, Tamer M. Ismail, M. Abd El Salam

Abstract:

This work presents a robot called Conceptual Robotic Cube, CR-Cube. The robot can be used as an educational tool for children from the age of three. It has a cube shape attached with a camera colours sensor. In addition, it contains four wheels to move smoothly. The researchers prepared a questionnaire to measure the efficiency of the robot. The design and the questionnaire was presented to 11 experts who agreed that the robot is appropriate for learning numbering and colours for preschool children.

Keywords: CR-Cube, robotic cube, conceptual robot, conceptual cube, colour concept, early childhood education

Procedia PDF Downloads 383
1623 Technological Development and Implementation of a Robotic Arm Motioned by Programmable Logic Controller

Authors: J. G. Batista, L. J. de Bessa Neto, M. A. F. B. Lima, J. R. Leite, J. I. de Andrade Nunes

Abstract:

The robot manipulator is an equipment that stands out for two reasons: Firstly because of its characteristics of movement and reprogramming, resembling the arm; secondly, by adding several areas of knowledge of science and engineering. The present work shows the development of the prototype of a robotic manipulator driven by a Programmable Logic Controller (PLC), having two degrees of freedom, which allows the movement and displacement of mechanical parts, tools, and objects in general of small size, through an electronic system. The aim is to study direct and inverse kinematics of the robotic manipulator to describe the translation and rotation between two adjacent links of the robot through the Denavit-Hartenberg parameters. Currently, due to the many resources that microcomputer systems offer us, robotics is going through a period of continuous growth that will allow, in a short time, the development of intelligent robots with the capacity to perform operations that require flexibility, speed and precision.

Keywords: Denavit-Hartenberg, direct and inverse kinematics, microcontrollers, robotic manipulator

Procedia PDF Downloads 310
1622 Robotic Assistance in Nursing Care: Survey on Challenges and Scenarios

Authors: Pascal Gliesche, Kathrin Seibert, Christian Kowalski, Dominik Domhoff, Max Pfingsthorn, Karin Wolf-Ostermann, Andreas Hein

Abstract:

Robotic assistance in nursing care is an increasingly important area of research and development. Facing a shortage of labor and an increasing number of people in need of care, the German Nursing Care Innovation Center (Pflegeinnovationszentrum, PIZ) aims to address these challenges from the side of technology. Little is known about nurses experiences with existing robotic assistance systems. Especially nurses perspectives on starting points for the development of robotic solutions, that target recurring burdensome tasks in everyday nursing care, are of interest. This paper presents findings focusing on robotics resulting from an explanatory mixed-methods study on nurses experiences with and their expectations for innovative technologies in nursing care in stationary and ambulant care facilities and hospitals in Germany. Based on the findings, eight scenarios for robotic assistance are identified based on the real needs of practitioners. An initial system addressing a single use-case is described to show perspectives for the use of robots in nursing care.

Keywords: robotics and automation, engineering management, engineering in medicine and biology, medical services, public health-care

Procedia PDF Downloads 126
1621 Strategy and Maze Surgery (Atrial fibrillation Surgery)

Authors: Shirin Jalili, Ramin Ghasemi Shayan

Abstract:

Atrial fibrillation is the foremost common arrhythmia around the world, with expanding recurrence famous with age. Thromboembolic occasions and strokes are the number one cause of mortality and morbidity. For patients who don't react to restorative treatment for rate and beat control, the maze method offers an elective treatment mediation. pharmaco-medical treatment for atrial fibrillation is pointed at the control of rate or cadence, intrusive treatment for atrial fibrillation is pointed at cadence control. An obtrusive approach may comprise of percutaneous catheter treatment, surgery, or a crossover approach. Since the maze method is recognized as the foremost successful way to dispense with AF, combining the maze strategy amid major cardiac surgeries has been received in clinical hone. the maze strategy, moreover known as Cox¬maze iii or the ‘cut¬and¬sew’ method, involves making different incisions within the atria to make an arrangement of scars that dispose of each potential zone of re¬entry. The electrical drive is constrained through a maze of scars that coordinates the electrical drive from the sinus node to the av node. By settling the headstrong period between ranges of scar, re¬entry is disposed of. in this article, we evaluate the Maze surgery method that's the surgical method of choice for the treatment of restorative atrial fibrillation.

Keywords: atrial fibrillation, congenital heart disease, procedure, maze surgery, treatment

Procedia PDF Downloads 109
1620 Out of Hospital Cardiac Arrest in Kuala Lumpur: A Mixed Method Study on Incidence, Adherence to Protocol, and Issues

Authors: Mohd Said Nurumal, Sarah Sheikh Abdul Karim

Abstract:

Information regarding out of hospital cardiac arrest incidence include outcome in Malaysia is limited and fragmented. This study aims to identify incidence and adherence to protocol of out of hospital cardiac arrest and also to explore the issues faced by the pre-hospital personnel in regards managing cardiac arrest victim in Kuala Lumpur, Malaysia. A mixed method approach combining the qualitative and quantitative study design was used. The 285 pre-hospital care data sheet of out of hospital cardiac arrest during the year of 2011 were examined by using checklists for identify the incidence and adherence to protocol. Nine semi-structured interviews and two focus group discussions were performed. For the incidence based on the overall out of hospital cardiac arrest cases that occurred in 2011 (n=285), the survival rates were 16.8%. For adherence to protocol, only 89 (41.8%) of the cases adhered to the given protocol and 124 did not adhere to such protocol. The qualitative information provided insight about the issues related to out of hospital cardiac arrest in every aspect. All the relevant qualitative data were merged into few categories relating issues that could affect the management of out of hospital cardiac arrest performed by pre-hospital care team. One of the essential elements in the out of hospital cardiac arrest handling by pre-hospital care is to ensure increase of survival rates and excellent outcomes by adhering to given protocols based on international standard benchmarks. Measures are needed to strengthen the quick activation of the pre-hospital care service, prompt bystander cardiopulmonary resuscitation, early defibrillation and timely advanced cardiac life support and also to tackle all the issues highlighted in qualitative results.

Keywords: pre-hospital care, out of hospital cardiac arrest, incidence, protocol, mixed method research

Procedia PDF Downloads 390
1619 Different Types of Amyloidosis Revealed with Positive Cardiac Scintigraphy with Tc-99M DPD-SPECT

Authors: Ioannis Panagiotopoulos, Efstathios Kastritis, Anastasia Katinioti, Georgios Efthymiadis, Argyrios Doumas, Maria Koutelou

Abstract:

Introduction: Transthyretin amyloidosis (ATTR) is a rare but serious infiltrative disease. Myocardial scintigraphy with DPD has emerged as the most effective, non-invasive, highly sensitive, and highly specific diagnostic method for cardiac ATTR amyloidosis. However, there are cases in which additional laboratory investigations reveal AL amyloidosis or other diseases despite a positive DPD scintigraphy. We describe the experience from the Onassis Cardiac Surgery Center and the monitoring center for infiltrative myocardial diseases of the cardiology clinic at AHEPA. Materials and Methods: All patients with clinical suspicion of cardiac or extracardiac amyloidosis undergo a myocardial scintigraphy scan with Tc-99m DPD. In this way, over 500 patients have been examined. Further diagnostic approach based on clinical and imaging findings includes laboratory investigation and invasive techniques (e.g., biopsy). Results: Out of 76 patients in total with positive myocardial scintigraphy Grade 2 or 3 according to the Perugini scale, 8 were proven to suffer from AL Amyloidosis during the investigation of paraproteinemia. Among these patients, 3 showed Grade 3 uptake, while the rest were graded as Grade 2, or 2 to 3. Additionally, one patient presented diffuse and unusual radiopharmaceutical uptake in soft tissues throughout the body without cardiac involvement. These findings raised suspicions, leading to the analysis of κ and λ light chains in the serum, as well as immunostaining of proteins in the serum and urine of these specific patients. The final diagnosis was AL amyloidosis. Conclusion: The value of DPD scintigraphy in the diagnosis of cardiac amyloidosis from transthyretin is undisputed. However, positive myocardial scintigraphy with DPD should not automatically lead to the diagnosis of ATTR amyloidosis. Laboratory differentiation between ATTR and AL amyloidosis is crucial, as both prognosis and therapeutic strategy are dramatically altered. Laboratory exclusion of paraproteinemia is a necessary and essential step in the diagnostic algorithm of ATTR amyloidosis for all positive myocardial scintigraphy with diphosphonate tracers since >20% of patients with Grade 3 and 2 uptake may conceal AL amyloidosis.

Keywords: AL amyloidosis, amyloidosis, ATTR, myocardial scintigraphy, Tc-99m DPD

Procedia PDF Downloads 35
1618 Using Electrical Impedance Tomography to Control a Robot

Authors: Shayan Rezvanigilkolaei, Shayesteh Vefaghnematollahi

Abstract:

Electrical impedance tomography is a non-invasive medical imaging technique suitable for medical applications. This paper describes an electrical impedance tomography device with the ability to navigate a robotic arm to manipulate a target object. The design of the device includes various hardware and software sections to perform medical imaging and control the robotic arm. In its hardware section an image is formed by 16 electrodes which are located around a container. This image is used to navigate a 3DOF robotic arm to reach the exact location of the target object. The data set to form the impedance imaging is obtained by having repeated current injections and voltage measurements between all electrode pairs. After performing the necessary calculations to obtain the impedance, information is transmitted to the computer. This data is fed and then executed in MATLAB which is interfaced with EIDORS (Electrical Impedance Tomography Reconstruction Software) to reconstruct the image based on the acquired data. In the next step, the coordinates of the center of the target object are calculated by image processing toolbox of MATLAB (IPT). Finally, these coordinates are used to calculate the angles of each joint of the robotic arm. The robotic arm moves to the desired tissue with the user command.

Keywords: electrical impedance tomography, EIT, surgeon robot, image processing of electrical impedance tomography

Procedia PDF Downloads 240
1617 Balanced Ischemia Misleading to a False Negative Myocardial Perfusion Imaging (Stress) Test

Authors: Devam Sheth

Abstract:

Nuclear imaging with stress myocardial perfusion (stress test) is the preferred first line investigation for noninvasive evaluation of ischaemic heart condition. The sensitivity of this test is close to 90 % making it a very reliable test. However, rarely it gives a false negative result which can be explained by the phenomenon termed as “balanced ischaemia”. We present the case of a 78 year Caucasian female without any significant past cardiac history, who presents with chest pain and shortness of breath since one day. The initial ECG and cardiac enzymes were non-impressive. Few hours later, she had some substernal chest pain along with some ST segment depression in the lateral leads. Stress test comes back negative for any significant perfusion defects. However, given her typical symptoms, she underwent a cardiac catheterization which revealed significant triple vessel disease mandating her to get a bypass surgery. This unusual phenomenon of false nuclear stress test in the setting of positive ECG changes can be explained only by balanced ischemia wherein due to global myocardial ischemia, the stress test fails to reveal relative perfusion defects in the affected segments.

Keywords: balanced, false positive, ischemia, myocardial perfusion imaging

Procedia PDF Downloads 271
1616 Development of a Three-Dimensional-Flywheel Robotic System

Authors: Chung-Chun Hsiao, Yu-Kai, Ting, Kai-Yuan Liu, Pang-Wei Yen, Jia-Ying Tu

Abstract:

In this paper, a new design of spherical robotic system based on the concepts of gimbal structure and gyro dynamics is presented. Robots equipped with multiple wheels and complex steering mechanics may increase the weight and degrade the energy transmission efficiency. In addition, the wheeled and legged robots are relatively vulnerable to lateral impact and lack of lateral mobility. Therefore, the proposed robotic design uses a spherical shell as the main body for ground locomotion, instead of using wheel devices. Three spherical shells are structured in a similar way to a gimbal device and rotate like a gyro system. The design and mechanism of the proposed robotic system is introduced. In addition, preliminary results of the dynamic model based on the principles of planar rigid body kinematics and Lagrangian equation are included. Simulation results and rig construction are presented to verify the concepts.

Keywords: gyro, gimbal, lagrange equation, spherical robots

Procedia PDF Downloads 282
1615 Non Immersive Virtual Laboratory Applied to Robotics Arms

Authors: Luis F. Recalde, Daniela A. Bastidas, Dayana E. Gallegos, Patricia N. Constante, Victor H. Andaluz

Abstract:

This article presents a non-immersive virtual lab-oratory to emulate the behavior of the Mitsubishi Melfa RV 2SDB robotic arm, allowing students and users to acquire skills and experience related to real robots, augmenting the access and learning of robotics in Universidad de las Fuerzas Armadas (ESPE). It was developed using the mathematical model of the robotic arm, thus defining the parameters for virtual recreation. The environment, interaction, and behavior of the robotic arm were developed in a graphic engine (Unity3D) to emulate learning tasks such as in a robotics laboratory. In the virtual system, four inputs were developed for the movement of the robot arm; further, to program the robot, a user interface was created where the user selects the trajectory such as point to point, line, arc, or circle. Finally, the hypothesis of the industrial robotic learning process is validated through the level of knowledge acquired after using the system.

Keywords: virtual learning, robot arm, non-immersive reality, mathematical model

Procedia PDF Downloads 69