Search results for: laparoscopic repair
615 Results of Twenty Years of Laparoscopic Hernia Repair Surgeries
Authors: Arun Prasad
Abstract:
Introduction: Laparoscopic surgery of hernia started in early 1990 and has had a mixed acceptance across the world, unlike laparoscopic cholecystectomy that has become a gold standard. Laparoscopic hernia repair claims to have less pain, less recurrence, and less wound infection compared to open hernia repair leading to early recovery and return to work. Materials and Methods: Laparoscopic hernia repair has been done in 2100 patients from 1995 till now with a follow-up data of 1350 patients. Data was analysed for results and satisfaction. Results: There is a recurrence rate of 0.1%. Early complications include bleeding, trocar injury and nerve pain. Late complications were rare. Conclusion: Laparoscopic inguinal hernia repair has a steep learning curve but after that the results and patient satisfaction are very good. It should be the procedure of choice in all bilateral and recurrent hernias.Keywords: laparoscopy, hernia, mesh, surgery
Procedia PDF Downloads 254614 Comparative Study of Outcomes of Nonfixation of Mesh versus Fixation in Laparoscopic Total Extra Peritoneal (TEP) Repair of Inguinal Hernia: A Prospective Randomized Controlled Trial
Authors: Raman Sharma, S. K. Jain
Abstract:
Aims and Objectives: Fixation of the mesh during laparoscopic total extraperitoneal (TEP) repair of inguinal hernia is thought to be necessary to prevent recurrence. However, mesh fixation may increase surgical complications and postoperative pain. Our objective was to compare the outcomes of nonfixation with fixation of polypropylene mesh by metal tacks during TEP repair of inguinal hernia. Methods: Forty patients aged 18 to72 years with inguinal hernia were included who underwent laparoscopic TEP repair of inguinal hernia with (n=20) or without (n=20) fixation of the mesh. The outcomes were operative duration, postoperative pain score, cost, in-hospital stay, time to return to normal activity, and complications. Results: Patients in whom the mesh was not fixed had shorter mean operating time (p < 0.05). We found no difference between groups in the postoperative pain score, incidence of recurrence, in-hospital stay, time to return to normal activity and complications (P > 0.05). Moreover, a net cost savings was realized for each hernia repair performed without stapled mesh. Conclusions: TEP repair without mesh fixation resulted in the shorter operating time and lower operative cost with no difference between groups in the postoperative pain score, incidence of recurrence, in-hospital stay, time to return to normal activity and complications. All this contribute to make TEP repair without mesh fixation a better choice for repair of uncomplicated inguinal hernia, especially in developing nations with scarce resources.Keywords: postoperative pain score, inguinal hernia, nonfixation of mesh, total extra peritoneal (TEP)
Procedia PDF Downloads 345613 Laparoscopic Management of Small Bowel Obstruction: An Unusual Case of Mechanical Obstruction Due to Appendiceal Adhesions
Authors: Veera J. Allu, Shreya Pal, Anang Pangeni
Abstract:
Introduction: Adhesive small bowel obstruction (ASBO) is usually managed conservatively. Failed conservative management leads to operative intervention by an open approach. However, laparoscopic management of ASBO is increasingly being reported in the literature. We report an unusual case of ASBO secondary to a band from the appendicular tip which was managed laparoscopically. Case Description: This patient was a 61-year-old female, otherwise fit and healthy, presenting with abdominal pain and mild distension with vomiting of 3 days duration. She had undergone ultrasound-guided drainage of an appendicular abscess three months ago and laparoscopic right inguinal hernia repair (TEP) in the past. CTAP showed small bowel obstruction with a transition point in the pelvis and the possible cause being adhesions. She was initially managed conservatively; however, as she was not improving for two days, she was consented to diagnostic laparoscopy. Intraoperatively, an adhesive band was found between the appendicular tip and distal ileum around 100cm proximal to the ileocolic junction, resulting in mechanical bowel obstruction. Laparoscopic division of band was performed, followed by appendicectomy, and the patient had an uneventful recovery and was discharged on postoperative day 1. Conclusion: In highly selected patients and with appropriate expertise, laparoscopic management of ASBO is feasible and safe.Keywords: bowel obstruction, adhesions, laparoscopy, open procedure
Procedia PDF Downloads 87612 Use of a Laparoscopic Approach in Urgent Adhesive Small Bowel Obstructions
Authors: Nuhi Arslani, Aleks Brumec
Abstract:
Adhesive small bowel obstruction (ASBO) accounts for 20% of emergency surgical procedures and intraabdominal adhesions account for 65% of such cases. In a 10-year post-operative period of abdominal surgery patients, around 35% of them will be readmitted because of ASBO. The first step in approaching ASBOs is using the Bologna guidelines, which include a thorough initial evaluation to diagnose or rule out an ASBO and then proceed with either further imaging studies or emergency surgery, which can be either open or laparoscopic. The contraindications for a laparoscopic approach include hemodynamic instability of the patient and infections in the peritoneum or port sites. Studies have shown that a laparoscopic approach to adhesiolysis is linked with a significantly smaller risk of readmissions and reoperations as well as with faster recovery time and fewer postoperative infections, but has a higher risk of bowel injuries, so a careful selection of patients is required. Although studies favor a laparoscopic approach, many countries still prefer a laparotomy, often because a laparoscopic approach requires surgeons to be highly skilled in the procedure. In the US and UK, between 50 and 60% of surgeons would approach an ASBO with laparoscopy, while in Italy, this number is around 15% and it is most likely similar in Slovenia. We believe that in the right cases and in the right patients, a laparoscopic approach can be equally feasible for treating ASBOs and is associated with fewer intraoperative and postoperative complications.Keywords: adhesive small bowel obstruction, laparoscopy, adhesions, adhesiolysis
Procedia PDF Downloads 87611 Optimal Replacement Period for a One-Unit System with Double Repair Cost Limits
Authors: Min-Tsai Lai, Taqwa Hariguna
Abstract:
This paper presents a periodical replacement model for a system, considering the concept of single and cumulative repair cost limits simultaneously. The failures are divided into two types. Minor failure can be corrected by minimal repair and serious failure makes the system breakdown completely. When a minor failure occurs, if the repair cost is less than a single repair cost limit L1 and the accumulated repair cost is less than a cumulative repair cost limit L2, then minimal repair is executed, otherwise, the system is preventively replaced. The system is also replaced at time T or at serious failure. The optimal period T minimizing the long-run expected cost per unit time is verified to be finite and unique under some specific conditions.Keywords: repair-cost limit, cumulative repair-cost limit, minimal repair, periodical replacement policy
Procedia PDF Downloads 366610 Low-Cost Robotic-Assisted Laparoscope
Authors: Ege Can Onal, Enver Ersen, Meltem Elitas
Abstract:
Laparoscopy is a surgical operation, well known as keyhole surgery. The operation is performed through small holes, hence, scars of a patient become much smaller, patients can recover in a short time and the hospital stay becomes shorter in comparison to an open surgery. Several tools are used at laparoscopic operations; among them, the laparoscope has a crucial role. It provides the vision during the operation, which will be the main focus in here. Since the operation area is very small, motion of the surgical tools might be limited in laparoscopic operations compared to traditional surgeries. To overcome this limitation, most of the laparoscopic tools have become more precise, dexterous, multi-functional or automated. Here, we present a robotic-assisted laparoscope that is controlled with pedals directly by a surgeon. Thus, the movement of the laparoscope might be controlled better, so there will not be a need to calibrate the camera during the operation. The need for an assistant that controls the movement of the laparoscope will be eliminated. The duration of the laparoscopic operation might be shorter since the surgeon will directly operate the camera.Keywords: laparoscope, laparoscopy, low-cost, minimally invasive surgery, robotic-assisted surgery
Procedia PDF Downloads 342609 It Is Time to Perform Total Laparoscopic Hysterectomy (TLH) without the Use of Uterine Manipulator: Kamran's TLH
Authors: Ahmed Gendia, Waseem Kamran
Abstract:
Objective: Total Laparoscopic hysterectomy (TLH) remains a common approach among laparoscopic surgeons. However, this approach depends on the use of uterine manipulator to facilitate the surgery. Although many studies reported the effectiveness of TLH with uterine manipulator, only few reported TLH without the use of any uterine or vaginal manipulation. the aim of this report is to demonstrate our Technique (kamran's TLH) in performing TLH without the use of any uterine or vaginal manipulation in benign conditions and report our intra- and post-operative outcomes. Methodology : surgical technique will be demonstrated through a short video highlighting the easy and safe to learn surgical steps. Additionally, the data of 86 patients who underwent KTLH for benign condition were retrospectively analyzed. the data included intra- and postoperative finding and complications. Results : A total of 86 hysterectomies were performed utilizing the Kamran's TLH ( KTHL). Mean age was 52.2 (±11) years old and BMI was 28.2(±7). Mean operative time was 64.7(±27.9) minutes and estimated bloods loss was 46.2(±54.6) ml. No intraoperative complications were recorded and there was no conversion to open surgery. Only one patient required readmission and surgery for vaginal vault dehiscence. Conclusion & Significance: Uterine manipulator is a key component in performing laparoscopic hysterectomy. However, our approach demonstrated that TLH can be safely performed without the use of any uterine or vaginal manipulation.Keywords: laparoscopic hystrectomy, TLH, uterine manipulator, surgery
Procedia PDF Downloads 156608 A Current Problem for Steel Bridges: Fatigue Assessment of Seams´ Repair
Authors: H. Pasternak, A. Chwastek
Abstract:
The paper describes the results from a research project about repair of welds. The repair was carried out by grinding the flawed seams and re-welding them. The main task was to determine the FAT classes of original state and after repair of seams according to the assessment procedures, such as nominal, structural and effective notch stress approach. The first part shows the results of the tests, the second part encloses numerical analysis and evaluation of results to determine the fatigue strength classes according to three assessment procedures.Keywords: cyclic loading, fatigue crack, post-weld treatment, seams’ repair
Procedia PDF Downloads 260607 Laparoscopic Management of Cysts Mimicking Hepatic Cystic Echinococcosis in Children (A Case Series)
Authors: Assia Haif, Djelloul Achouri, Zineddine Soualili
Abstract:
Introduction: Laparoscopic treatment of liver echinococcosis cyst has become popular. In parallel, the diagnostic approach of cystic liver lesions is based on the number of lesions and their distribution. The etiologies of cystic masses in children are different, and the role of imaging in their characterization and pre-therapeutic evaluation is essential. The main differential diagnoses of hepatic hydatid cysts can be discovered intraoperatively by minimally invasive surgery. Methods: The clinical data contained seven patients with hepatic cystic who underwent laparoscopic surgery in the Department of Pediatric Surgery, SETIF, Algeria, from 2015 to 2022. Results: Of reported seven patients, five are male, and the remaining two are female. Abdominal pain was the most frequent clinical signs. Biological parameters were within normal limits, Abdominal ultrasound, practiced in all cases, completed by abdominal computed tomography (CT), showed a hydatid cystic. For all patients, surgical procedures were performed under laparoscopy. Total cystectomy in four patients, fenestration or subtotal cystectomy in three patients, respectively. A histopathological feature confirmed the nature of the cysts. During the follow-up period, there was no recurrence. Conclusions: Laparoscopic liver surgery is a safe and effective approach, it is an alternative to conventional surgery and a reproducible method. Laparoscopic surgery approach should follow the same principals with those of open surgery. This surgical technique can rectify the diagnosis of hydatid cyst, the histopathological examination confirms the nature of the cystic lesion.Keywords: children, cyst, echinococcosis, laparoscopic, liver
Procedia PDF Downloads 139606 An Ergonomic Handle Design for Instruments in Laparoscopic Surgery
Authors: Ramon Sancibrian, Carlos Redondo-Figuero, Maria C. Gutierrez-Diez, Esther G. Sarabia, Maria A. Benito-Gonzalez, Jose C. Manuel-Palazuelos
Abstract:
In this paper, the design and evaluation of a handle for laparoscopic surgery is presented. The design of the handle is based on ergonomic principles and tries to avoid awkward postures for surgeons. The handle combines the so-called power-grip and accurate-grip in order to provide strength and accuracy in the performance of surgery. The handle is tested using both objective and subjective approaches. The objective approach uses motion capture techniques to obtain the angles of forearm, arm, wrist and hand. The muscular effort is obtained with electromyography electrodes. On the other hand, a subjective survey has been carried out using questionnaires. Results confirm that the handle is preferred by the majority of the surgeons.Keywords: laparoscopic surgery, ergonomics, mechanical design, biomechanics
Procedia PDF Downloads 502605 Retrofitting of Historical Structures in Van City
Authors: Eylem Güzel, Mustafa Gülen
Abstract:
Historical structures are the most important symbols of a country that link the past with the future. In order to transfer them in their present conditions to the next generations, maintaining these historical structures are one of our main tasks. Seismic performance of historical structures damaged by the earthquake effects can be enhanced by repair and retrofitting applications. However, repair and retrofitting applications of historical structures are more complicated compared with the traditional structures. For this reason, they need much more attention in repair and retrofitting applications to preserve the spirit of historical structures. In this study, the present condition of selected historical structures built up in Van city that has a very rich historical heritage is given and the necessity of repair and retrofitting applications of historical structures are debated in detail.Keywords: historical structures, repair, retrofitting, Van city
Procedia PDF Downloads 355604 Structural Rehabilitation, Retrofitting and Strengthening of Reinforced Concrete Structures
Authors: Manish Kumar
Abstract:
Reinforced cement concrete is getting extensively used for construction of different type of structures for the last one century. During this period, we have constructed many structures like buildings, bridges, industrial structures, pavement, water tanks etc. using this construction material. These structures have been created with huge investment of resources. It is essential to maintain those structures in functional condition. Since deterioration in RCC Structures is a common and natural phenomenon it is required to have a detailed plan, methodology for structural repair and rehabilitation shall be in place for dealing such issues. It is important to know exact reason of distress, type of distress and correct method of repair concrete structures. The different methods of repair are described in paper according to distress category which can be refereed for repair. Major finding of the study is that to protect our structure we need to have maintenance frequency and correct material to be chosen for repair. Also workmanship during repair needs to be taken utmost care for quality repair.Keywords: deterioration, functional condition, reinforced cement concrete, resources
Procedia PDF Downloads 253603 A Case Study on the Field Surveys and Repair of a Marine Approach-Bridge
Authors: S. H. Park, D. W. You
Abstract:
This study is about to the field survey and repair works in a marine approach-bride. In order to evaluate the stability of the ground and the structure, field surveys such as exterior inspection, non-destructive inspection, measurement, and geophysical exploration are carried out. Numerical analysis is conducted to investigate the cause of the abutment displacement at the same time. In addition, repair works are practiced to the region damaged with intent to sustain long-term safety.Keywords: field survey, expansion joint, repair, maintenance
Procedia PDF Downloads 292602 Assertion-Driven Test Repair Based on Priority Criteria
Authors: Ruilian Zhao, Shukai Zhang, Yan Wang, Weiwei Wang
Abstract:
Repairing broken test cases is an expensive and challenging task in evolving software systems. Although an automated repair technique with intent preservation has been proposed, but it does not take into account the association between test repairs and assertions, leading to a large number of irrelevant candidates and decreasing the repair capability. This paper proposes an assertion-driven test repair approach. Furthermore, an intent-oriented priority criterion is raised to guide the repair candidate generation, making the repairs closer to the intent of the test. In more detail, repair targets are determined through post-dominance relations between assertions and the methods that directly cause compilation errors. Then, test repairs are generated from the target in a bottom-up way, guided by the intent-oriented priority criteria. Finally, the generated repair candidates are prioritized to match the original test intent. The approach is implemented and evaluated on the benchmark of 4 open-source programs and 91 broken test cases. The result shows that the approach can fix 89% (81/91) of broken test cases, which is more effective than the existing intentpreserved test repair approach, and our intent-oriented priority criteria work well.Keywords: test repair, test intent, software test, test case evolution
Procedia PDF Downloads 130601 Laparoscopic Proximal Gastrectomy in Gastroesophageal Junction Tumours
Authors: Ihab Saad Ahmed
Abstract:
Background For Siewert type I and II gastroesophageal junction tumor (GEJ) laparoscopic proximal gastrectomy can be performed. It is associated with several perioperative benefits compared with open proximal gastrectomy. The use of laparoscopic proximal gastrectomy (LPG) has become an increasingly popular approach for select tumors Methods We describe our technique for LPG, including the preoperative work-up, illustrated images of the main principle steps of the surgery, and our postoperative course. Results Thirteen pts (nine males, four female) with type I, II (GEJ) adenocarcinoma had laparoscopic radical proximal gastrectomy and D2 lymphadenectomy. All of our patient received neoadjuvant chemotherapy, eleven patients had intrathoracic anastomosis through mini thoracotomy (two hand sewn end to end anastomoses and the other 9 patient end to side using circular stapler), two patients with intrathoracic anastomosis had flap and wrap technique, two patients had thoracoscopic esophageal and mediastinal lymph node dissection with cervical anastomosis The mean blood loss 80ml, no cases were converted to open. The mean operative time 250 minute Average LN retrieved 19-25, No sever complication such as leakage, stenosis, pancreatic fistula ,or intra-abdominal abscess were reported. Only One patient presented with empyema 1.5 month after discharge that was managed conservatively. Conclusion For carefully selected patients, LPG in GEJ tumour type I and II is a safe and reasonable alternative for open technique , which is associated with similar oncologic outcomes and low morbidity. It showed less blood loss, respiratory infections, with similar 1- and 3-year survival rates.Keywords: LPG(laparoscopic proximal gastrectomy, GEJ( gastroesophageal junction tumour), d2 lymphadenectomy, neoadjuvant cth
Procedia PDF Downloads 125600 Robotic Assisted vs Traditional Laparoscopic Partial Nephrectomy Peri-Operative Outcomes: A Comparative Single Surgeon Study
Authors: Gerard Bray, Derek Mao, Arya Bahadori, Sachinka Ranasinghe
Abstract:
The EAU currently recommends partial nephrectomy as the preferred management for localised cT1 renal tumours, irrespective of surgical approach. With the advent of robotic assisted partial nephrectomy, there is growing evidence that warm ischaemia time may be reduced compared to the traditional laparoscopic approach. There is still no clear differences between the two approaches with regards to other peri-operative and oncological outcomes. Current limitations in the field denote the lack of single surgeon series to compare the two approaches as other studies often include multiple operators of different experience levels. To the best of our knowledge, this study is the first single surgeon series comparing peri-operative outcomes of robotic assisted and laparoscopic PN. The current study aims to reduce intra-operator bias while maintaining an adequate sample size to assess the differences in outcomes between the two approaches. We retrospectively compared patient demographics, peri-operative outcomes, and renal function derangements of all partial nephrectomies undertaken by a single surgeon with experience in both laparoscopic and robotic surgery. Warm ischaemia time, length of stay, and acute renal function deterioration were all significantly reduced with robotic partial nephrectomy, compared to laparoscopic nephrectomy. This study highlights the benefits of robotic partial nephrectomy. Further prospective studies with larger sample sizes would be valuable additions to the current literature.Keywords: partial nephrectomy, robotic assisted partial nephrectomy, warm ischaemia time, peri-operative outcomes
Procedia PDF Downloads 141599 Evaluation of Surgical Site Infection in Bile Spillage Cases Compared to Non Bile Spillage Cases Following Laparoscopic Cholecystectomy
Authors: Ishwor Paudel, Pratima Gautam, Sandeep Bhattarai
Abstract:
Bile spillage occurs frequently during laparoscopic cholecystectomy yet its impact on postoperative outcomes remains unknown. It might not be as innocuous as some surgeons tend to believe and in fact, might be associated with post-operative surgical site infections (SSI). It often leads to patient dissatisfaction, emergency department visits, with subsequent readmission and additional procedures. While some authors found no increase in SSI following bile spillage (BS) compared to non-bile spillage cases, others found bile spillage to be associated with SSI. Therefore we sought to examine whether bile spillage is indeed associated with an increased risk of postoperative wound infections after laparoscopic cholecystectomy. I hypothesize that patients who experience BS during operation, have an increased risk of SSI compared to those who do not. This is a prospective observational study conducted in the Department of Surgery, Patan Hospital over a period of one year. Patients undergoing Laparoscopic cholecystectomy were included and bile spillage, if happened was noted. All cases were followed up for 30 days and SSI was diagnosed as per CDC-defined criteria. Fisher’s test was applied to compare SSI in bile spillage versus non-bile spillage cases. A total of 112 patients were included in the final analysis. Bile spillage occurred in 20 cases and was absent in the rest i.e.92 cases. Among bile spillage cases, SSI was found in 4 cases (20%), whereas in nonbile spillage cases, SSI was found in 8 cases (8.7%). However, it was statistically not significant (p-value>0.05). Eleven (92%) cases were superficial SSI and one was an organ-space infection. No mortality or 30-day readmission. Spillage of Gallbladder content does not lead to an increase in SSIs. However as the rate of SSI is still higher, Surgeons should be careful to avoid iatrogenic gallbladder perforation and in case of bile spillage thorough peritoneal irrigation with normal saline should be done.Keywords: organ space infection, Laparoscopic cholecystectomy, biliary spillage, surgical site infection
Procedia PDF Downloads 77598 An Overview of Corroded Pipe Repair Techniques Using Composite Materials
Authors: Lim Kar Sing, Siti Nur Afifah Azraai, Norhazilan Md Noor, Nordin Yahaya
Abstract:
Polymeric composites are being increasingly used as repair material for repairing critical infrastructures such as building, bridge, pressure vessel, piping and pipeline. Technique in repairing damaged pipes is one of the major concerns of pipeline owners. Considerable researches have been carried out on the repair of corroded pipes using composite materials. This article attempts a short review of the subject matter to provide insight into various techniques used in repairing corroded pipes, focusing on a wide range of composite repair systems. These systems including pre-cured layered, flexible wet lay-up, pre-impregnated, split composite sleeve and flexible tape systems. Both advantages and limitations of these repair systems were highlighted. Critical technical aspects have been discussed through the current standards and practices. Research gaps and future study scopes in achieving more effective design philosophy are also presented.Keywords: composite materials, pipeline, repair technique, polymers
Procedia PDF Downloads 510597 Laparoscopic Curative Resection for Right-Sided Colonic Tumours: Initial Experience from a Cancer Hospital of a Developing Country
Authors: Awais Naeem, Osama Shakeel, Aamir Ali Syed, Shahid Khattak
Abstract:
Introduction: Laparoscopic right hemicolectomy is an advanced cancer surgery in today's era. The aim of this study was to evaluate the surgical and initial oncological outcomes after curative, laparoscopic resection of right sided colonic tumors. Also to compare our results with those of previous randomized trials. Methods And Procedures: We retrospectively analyzed the medical record files of all the patients who presented to our hospital with the diagnosis of right sided colon carcinoma from January 2012 to December 2017 and underwent laparoscopic right hemicolectomy. Demographics, operative findings and histopathological reports were all recorded on a preformed data sheet. All the analysis was performed on SPSS 20. Results: Total of 48 patients were included. There were 37 male and 11 female patients with mean age of 49.7 (range from 25 – 82). Mean hospital stay was 8.25 ± 3.17 days. Blood loss was 80mls and operative mean time was 240 minutes. Eighteen patients had extended right hemicolectomy. Median length of the specimen retrieved was 31cm (range, 14-59cm). Mean size of tumor was 6.44cm + 2.53. Total number of lymph nodes removed was 20.5 + 8.3. All had R0 resection. Post-operatively 2 patients had pelvic collection and there was no 30 day mortality. In 33 patients there was T3 disease, 5 had T2 and 10 had T4 disease. There was distant recurrence in 4 patients with peritoneal metastasis in 3 and liver metastasis in 1 patient. Forty-six patients are still alive and 44 are disease free. The mean follow-up period was 25.31 (12 to 60) months. Conclusion: Our early experience with Laparascopic Right hemicolectomy as a safe and oncologically feasible surgical option. We attained comparable surgical results with curative intent.Keywords: right hemicolectomy, right sided colonic tumors, laparoscopic, curative intent
Procedia PDF Downloads 128596 Repair of Cracked Aluminum Plate by Composite Patch
Authors: S. Lecheb, A. Nour, A. Chellil, H. Mechakra, A. Zeggane, H. Kebir
Abstract:
In this work, repaired crack in 6061-T6 aluminum plate with composite patches presented, firstly we determine the displacement, strain, and stress, also the first six mode shape of the plate, secondly we took the same model adding central crack initiation, which is located in the center of the plate, its size vary from 20 mm to 60 mm and we compare the first results with second. Thirdly, we repair various cracks with the composite patch (carbon/epoxy) and for (2 layers, 4 layers). Finally, the comparison of stress, strain, displacement and six first natural frequencies between un-cracked specimen, crack propagation and composite patch repair.Keywords: composite patch repair, crack growth, aluminum alloy plate, stress
Procedia PDF Downloads 600595 A Comparative Study of Granisetron and Palonosetron in Postoperative Nausea and Vomiting Following Laparoscopic Surgery
Authors: Burra Vijitha
Abstract:
A prospective randomized comparative study for the prevention of postoperative nausea and vomiting in the patients undergoing general anesthesia ,for elective laparoscopic surgeries with respect to efficacy and side effects of granisetron and palonosetron. Sixty adult patients of class ASA 1,2 of either sex in age group between 20-70 yrs,scheduled for elective laparoscopic surgeries were selected for the study.Patients were randomly divided into two groups 30 each. Group G: Granisetron group (n=30), 40µg/kg; Group P: Palonosetron group (n=30), 0.075 mg. at end of surgery before extubation group G patients 40 µg/kg of inj.granisetron and group P patients received 0.075 mg of inj.palonosetron slow iv over 30 sec.In post anesthesia care unit, episodes of nausea and vomiting experienced by each patient was recorded by direct questioning the patient .study medication was assessed in terms of incidence of nausea and vomiting during periods of 0-4 hrs,4-12 hrs,12-24 hrs,24-48hrs.our study demonstrated that complete response for those patients who received granisetron were 86.66%,80% and 66.66% ,while those received palonosetron were 100%,86.6%,90% between 0-4hrs,4-12hrs,12-24 hrs. It shows no statistically signidficant differences between the baseline values of hemodynamic variables beween two groups during study. Keywords: Granisetron, nausea, palonosetron, vomiting.Keywords: granisetron, palonosetron, nausea, vomiting
Procedia PDF Downloads 236594 A Radiographic Survey of Eggshell Powder Effect on Tibial Bone Defect Repair Tested in Dog
Authors: M. Yadegari, M. Nourbakhsh, N. Arbabzadeh
Abstract:
The skeletal system injuries are of major importance. In addition, it is recommended to use materials for hard tissue repair in open or closed fractures. It is important to use complex minerals with a beneficial effect on hard tissue repair, stimulating cell growth in the bone. Materials that could help avoid bone fracture inflammatory reaction and speed up bone fracture repair are of utmost importance in the treatment of bone fractures. Similar to minerals, the inner eggshell membrane consists of carbohydrates, lipids, proteins with the high pH, high calcium absorptive capacity and with faster bone fracture repair ability. In the present radiographic survey, eggshell-derived bone graft substitutes were used for bone defect repair in 8 dog tibia, measuring bone density on the day of implant placement and 30 and 60 days after placement. In fact, the result of this study shows the difference in bone growth and misshapen bones between treatment and control sites. Cell growth was adequate in treatment sites and misshapen bones were less frequent here than in control sites.Keywords: bone repair, eggshell powder, implant, radiography
Procedia PDF Downloads 322593 Analysis of Arthroscopic Rotator Cuff Repair
Authors: Prakash Karrun, M. Manoj Deepak, Mathivanan, K. Venkatachalam
Abstract:
Our study aims to evaluate the rates of healing and the efficacy of the arthroscopic repair of the rotator cuff tears. 40 patients who had rotator cuff tears were taken up for the study and arthroscopic repair was done with double row technique.They were evaluated and followed up for a minimum of 2 years minimum.The functional status,range of motion and healing rates were compared post operatively. All the patients were followed up with serial questionnaires and MRI at the end of 2 years. There was significant improvement in the functional status of the patient. The MRI showed better rates of healing in these patients.Thus our study effectively proves the efficacy of our operating technique.Keywords: rotator cuff tear, arthroscopic repair, double stich, healing
Procedia PDF Downloads 347592 Comparative Study of Non-Identical Firearms with Priority to Repair Subject to Inspection
Authors: A. S. Grewal, R. S. Sangwan, Dharambir, Vikas Dhanda
Abstract:
The purpose of this paper is to develop and analyze two reliability models for a system of non-identical firearms – one is standard firearm (called as original unit) and the other is a country-made firearm (called as duplicate /substandard unit). There is a single server who comes immediately to do inspection and repair whenever needed. On the failure of standard firearm, the server inspects the operative country-made firearm to see whether the unit is capable of performing the desired function well or not. If country-made firearm is not capable to do so, the operation of the system is stopped and server starts repair of the standard firearms immediately. However, no inspection is done at the failure of the country-made firearm as the country-made firearm alone is capable of performing the given task well. In model I, priority to repair the standard firearm is given in case system fails completely and country-made firearm is already under repair, whereas in model II there is no such priority. The failure and repair times of each unit are assumed to be independent and uncorrelated random variables. The distributions of failure time of the units are taken as negative exponential while that of repair and inspection times are general. By using semi-Markov process and regenerative point technique some econo-reliability measures are obtained. Graphs are plotted to compare the MTSF (mean time to system failure), availability and profit of the models for a particular case.Keywords: non-identical firearms, inspection, priority to repair, semi-Markov process, regenerative point
Procedia PDF Downloads 429591 Effect of Oral Clonidine Premedication on Subarachnoid Block Characteristics of 0.5 % Hyperbaric Bupivacaine for Laparoscopic Gynecological Procedures – A Randomized Control Study
Authors: Buchh Aqsa, Inayat Umar
Abstract:
Background- Clonidine, α 2 agonist, possesses several properties to make it valuable adjuvant for spinal anesthesia. The study was aimed to evaluate the clinical effects of oral clonidine premedication for laparoscopic gynecological procedures under subarachnoid block. Patients and method- Sixtyfour adult female patients of ASA physical status I and II, aged 25 to 45 years and scheduled for laparoscopic gynecological procedures under the subarachnoid block, were randomized into two comparable equal groups of 32 patients each to received either oral clonidine, 100 µg (Group I) or placebo (Group II), 90 minutes before the procedure. Subarachnoid block was established with of 3.5 ml of 0.5% hyperbaric bupivacaine in all patients. Onset and duration of sensory and motor block, maximum cephalad level, and the regression time to reach S1 sensory level were assessed as primary end points. Sedation, hemodynamic variability, and respiratory depression or any other side effects were evaluated as secondary outcomes. Results- The demographic profile was comparable. The intraoperative hemodynamic parameters showed significant differences between groups. Oral clonidine was accelerated the onset time of sensory and motor blockade and extended the duration of sensory block (216.4 ± 23.3 min versus 165 ± 37.2 min, P <0.05). The duration of motor block showed no significant difference. The sedation score was more than 2 in the clonidine group as compared to the control group. Conclusion- Oral clonidine premedication has extended the duration of sensory analgesia with arousable sedation. It also prevented the post spinal shivering of the subarachnoid block.Keywords: oral clonidine, subarachnoid block, sensory analgesia, laparoscopic gynaecological
Procedia PDF Downloads 83590 Advanced Techniques in Robotic Mitral Valve Repair
Authors: Abraham J. Rizkalla, Tristan D. Yan
Abstract:
Purpose: Durable mitral valve repair is preferred to a replacement, avoiding the need for anticoagulation or re-intervention, with a reduced risk of endocarditis. Robotic mitral repair has been gaining favour globally as a safe, effective, and reproducible method of minimally invasive valve repair. In this work, we showcase the use of the Davinci© Xi robotic platform to perform several advanced techniques, working synergistically to achieve successful mitral repair in advanced mitral disease. Techniques: We present the case of a Barlow type mitral valve disease with a tall and redundant posterior leaflet resulting in severe mitral regurgitation and systolic anterior motion. Firstly, quadrangular resection of P2 is performed to remove the excess and redundant leaflet. Secondly, a sliding leaflet plasty of P1 and P3 is used to reconstruct the posterior leaflet. To anchor the newly formed posterior leaflet to the papillary muscle, CV-4 Goretex neochordae are fashioned using the innovative string, ruler, and bulldog technique. Finally, mitral valve annuloplasty and closure of a patent foramen ovale complete the repair. Results: There was no significant residual mitral regurgitation and complete resolution of the systolic anterior motion of the mitral valve on post operative transoesophageal echocardiography. Conclusion: This work highlights the robotic approach to complex repair techniques for advanced mitral valve disease. Familiarity with resection and sliding plasty, neochord implantation, and annuloplasty allows the modern cardiac surgeon to achieve a minimally-invasive and durable mitral valve repair when faced with complex mitral valve pathology.Keywords: robotic mitral valve repair, Barlow's valve, sliding plasty, neochord, annuloplasty, quadrangular resection
Procedia PDF Downloads 87589 Management of Acute Biliary Pathology at Gozo General Hospital
Authors: Kristian Bugeja, Upeshala A. Jayawardena, Clarissa Fenech, Mark Zammit Vincenti
Abstract:
Introduction: Biliary colic, acute cholecystitis, and gallstone pancreatitis are some of the most common surgical presentations at Gozo General Hospital (GGH). National Institute for Health and Care Excellence (NICE) guidelines advise that suitable patients with acute biliary problems should be offered a laparoscopic cholecystectomy within one week of diagnosis. There has traditionally been difficulty in achieving this mainly due to the reluctance of some surgeons to operate in the acute setting, limited, timely access to MRCP and ERCP, and organizational issues. Methodology: A retrospective study was performed involving all biliary pathology-related admissions to GGH during the two-year period of 2019 and 2020. Patients’ files and electronic case summary (ECS) were used for data collection, which included demographic data, primary diagnosis, co-morbidities, management, waiting time to surgery, length of stay, readmissions, and reason for readmissions. NICE clinical guidance 188 – Gallstone disease were used as the standard. Results: 51 patients were included in the study. The mean age was 58 years, and 35 (68.6%) were female. The main diagnoses on admission were biliary colic in 31 (60.8%), acute cholecystitis in 10 (19.6%). Others included gallstone pancreatitis in 3 (5.89%), chronic cholecystitis in 2 (3.92%), gall bladder malignancy in 4 (7.84%), and ascending cholangitis in 1 (1.97%). Management included laparoscopic cholecystectomy in 34 (66.7%); conservative in 8 (15.7%) and ERCP in 6 (11.7%). The mean waiting time for laparoscopic cholecystectomy for patients with acute cholecystitis was 74 days – range being between 3 and 146 days since the date of diagnosis. Only one patient who was diagnosed with acute cholecystitis and managed with laparoscopic cholecystectomy was done so within the 7-day time frame. Hospital re-admissions were reported in 5 patients (9.8%) due to vomiting (1), ascending cholangitis (1), and gallstone pancreatitis (3). Discussion: Guidelines were not met for patients presenting to Gozo General Hospital with acute biliary pathology. This resulted in 5 patients being re-admitted to hospital while waiting for definitive surgery. The local issues resulting in the delay to surgery need to be identified and steps are taken to facilitate the provision of urgent cholecystectomy for suitable patients.Keywords: biliary colic, acute cholecystits, laparoscopic cholecystectomy, conservative management
Procedia PDF Downloads 161588 The Impact of Urethral Plate Width on Surgical Outcomes After Distal Hypospadias Repair in Children
Authors: Andrey Boyko
Abstract:
Nowadays, there is no consensus about the influence of urethral plate (UP) width on the surgical outcomes after distal hypospadias repair. The purpose of the research was to study the association between UP width and surgical outcomes after distal hypospadias repair in children. Materials and methods: The study included 138 patients with distal hypospadias. The mean age at the time of surgery was 4.6 years (6 months – 16 years). We measured UP width at the “midpoint within the glans” and used the HOSE scale to assess postoperative outcomes. The patients were divided into 2 groups: group 1 – the patients (107) with UP < 8mm, group 2 – patients (31) with UP > 8mm. All boys underwent TIP repair. Preincision means UP width after incision means UP width, and the UP ratio was analyzed. Statistical data were obtained using Statistica 10. Results: The findings were preincision mean UP width - 5.4 mm and 9.4 mm; after incision mean UP width - 13mm and 17.5 mm; UP ratio - 0.41 and 0.53 in group 1 and group 2, respectively. Most postoperative complications (fistula, meatal stenosis, and stricture) happened in patients with UP width < 8 mm versus ≥ 8 mm (7/107 versus 2/31, respectively). HOSE results were 15.77 (group 1), 15.65 (group 2). The follow up lasted up to 12 months. Statistical analysis proved the absence of correlation between UP width and postoperative complications. Conclusions: In conclusion, it should be noted that the success of surgical repair mostly depended on the surgical technique.Keywords: children, distal hypospadias, tip repair, urethral plate width
Procedia PDF Downloads 124587 Computation of Thermal Stress Intensity Factor for Bonded Composite Repairs in Aircraft Structures
Authors: Fayçal Benyahia, Abdelmohsen Albedah, Bel Abbes Bachir Bouiadjra
Abstract:
In this study the Finite element method is used to analyse the effect of the thermal residual stresses resulting from adhesive curing on the performances of the bonded composite repair in aircraft structures. The stress intensity factor at the crack tip is chosen as fracture criterion in order to estimate the repair performances. The obtained results show that the presence of the thermal residual stresses reduces considerably the repair performances and consequently decreases the fatigue life of cracked structures. The effects of the curing temperature, the adhesive properties and the adhesive thickness on the Stress Intensity Factor (SIF) variation with thermal stresses are also analysed.Keywords: bonded composite repair, residual stress, adhesion, stress transfer, finite element analysis
Procedia PDF Downloads 419586 AI-Driven Strategies for Sustainable Electronics Repair: A Case Study in Energy Efficiency
Authors: Badiy Elmabrouk, Abdelhamid Boujarif, Zhiguo Zeng, Stephane Borrel, Robert Heidsieck
Abstract:
In an era where sustainability is paramount, this paper introduces a machine learning-driven testing protocol to accurately predict diode failures, merging reliability engineering with failure physics to enhance repair operations efficiency. Our approach refines the burn-in process, significantly curtailing its duration, which not only conserves energy but also elevates productivity and mitigates component wear. A case study from GE HealthCare’s repair center vividly demonstrates the method’s effectiveness, recording a high prediction of diode failures and a substantial decrease in energy consumption that translates to an annual reduction of 6.5 Tons of CO2 emissions. This advancement sets a benchmark for environmentally conscious practices in the electronics repair sector.Keywords: maintenance, burn-in, failure physics, reliability testing
Procedia PDF Downloads 68