Search results for: eccentric training
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 3976

Search results for: eccentric training

3976 Expression of PGC-1 Alpha Isoforms in Response to Eccentric and Concentric Resistance Training in Healthy Subjects

Authors: Pejman Taghibeikzadehbadr

Abstract:

Background and Aim: PGC-1 alpha is a transcription factor that was first detected in brown adipose tissue. Since its discovery, PGC-1 alpha has been known to facilitate beneficial adaptations such as mitochondrial biogenesis and increased angiogenesis in skeletal muscle following aerobic exercise. Therefore, the purpose of this study was to investigate the expression of PGC-1 alpha isoforms in response to eccentric and concentric resistance training in healthy subjects. Materials and Methods: Ten healthy men were randomly divided into two groups (5 patients in eccentric group - 5 in eccentric group). Isokinetic contraction protocols included eccentric and concentric knee extension with maximum power and angular velocity of 60 degrees per second. The torques assigned to each subject were considered to match the workload in both protocols, with a rotational speed of 60 degrees per second. Contractions consisted of a maximum of 12 sets of 10 repetitions for the right leg, a rest time of 30 seconds between each set. At the beginning and end of the study, biopsy of the lateral broad muscle tissue was performed. Biopsies were performed in both distal and proximal directions of the lateral flank. To evaluate the expression of PGC1α-1 and PGC1α-4 genes, tissue analysis was performed in each group using Real-Time PCR technique. Data were analyzed using dependent t-test and covariance test. SPSS21 software and Exell 2013 software were used for data analysis. Results: The results showed that intra-group changes of PGC1α-1 after one session of activity were not significant in eccentric (p = 0.168) and concentric (p = 0.959) groups. Also, inter-group changes showed no difference between the two groups (p = 0.681). Also, intra-group changes of PGC1α-4 after one session of activity were significant in an eccentric group (p = 0.012) and concentric group (p = 0.02). Also, inter-group changes showed no difference between the two groups (p = 0.362). Conclusion: It seems that the lack of significant changes in the desired variables due to the lack of exercise pressure is sufficient to stimulate the increase of PGC1α-1 and PGC1α-4. And with regard to reviewing the answer, it seems that the compatibility debate has different results that need to be addressed.

Keywords: eccentric contraction, concentric contraction, PGC1α-1 و PGC1α-4, human subject

Procedia PDF Downloads 78
3975 Eccentric Connectivity Index, First and Second Zagreb Indices of Corona Graph

Authors: A. Kulandai Therese

Abstract:

The eccentric connectivity index based on degree and eccentricity of the vertices of a graph is a widely used graph invariant in mathematics.In this paper, we present the explicit eccentric connectivity index, first and second Zagreb indices for a Corona graph and sub division-related corona graphs.

Keywords: corona graph, degree, eccentricity, eccentric connectivity index, first zagreb index, second zagreb index, subdivision graphs

Procedia PDF Downloads 336
3974 The Effect of Low Power Laser on CK and Some of Markers Delayed Onset Muscle Soreness (DOMS)

Authors: Bahareh Yazdanparast Chaharmahali

Abstract:

The study showed effect of low power laser therapy on knee range of motion (flexion and extension), resting angle of knee joint, knee circumference and rating of delayed onset muscle soreness induced pain, 24 and 48 hours after eccentric training of knee flexor muscle (hamstring muscle). We investigate the effects of pulsed ultrasound on swelling, relaxed, flexion and extension knee angle and pain. 20 volunteers among girl students of college voluntary participated in this research. After eccentric training, subjects were randomly divided into two groups, control and laser therapy. In day 1 and in order to induce delayed onset muscle soreness, subjects eccentrically trained their knee flexor muscles. In day 2, subjects were randomly divided into two groups: control and low power laser therapy. 24 and 48 hours after eccentric training. Variables (knee flexion and extension, srang of motion, resting knee joint angle and knee circumferences) were measured and analyzed. Data are reported as means ± standard error (SE) and repeated measured was used to assess differences within groups. Methods of treatment (low power laser therapy) have significant effects on delayed onset muscle soreness markers. 24 and 48 hours after training a significant difference was observed between mean pains of 2 groups. This difference was significant between low power laser therapy and C groups. The Bonferroni post hock is significant. Low power laser therapy trophy as used in this study did significantly diminish the effects of delayed – onset muscle soreness on swelling, relaxed – knee extension and flexion angle.

Keywords: creatine kinase, DOMS, eccentric training, low power laser

Procedia PDF Downloads 246
3973 Amblyopia and Eccentric Fixation

Authors: Kristine Kalnica-Dorosenko, Aiga Svede

Abstract:

Amblyopia or 'lazy eye' is impaired or dim vision without obvious defect or change in the eye. It is often associated with abnormal visual experience, most commonly strabismus, anisometropia or both, and form deprivation. The main task of amblyopia treatment is to ameliorate etiological factors to create a clear retinal image and, to ensure the participation of the amblyopic eye in the visual process. The treatment of amblyopia and eccentric fixation is usually associated with problems in the therapy. Eccentric fixation is present in around 44% of all patients with amblyopia and in 30% of patients with strabismic amblyopia. In Latvia, amblyopia is carefully treated in various clinics, but eccentricity diagnosis is relatively rare. Conflict which has developed relating to the relationship between the visual disorder and the degree of eccentric fixation in amblyopia should to be rethoughted, because it has an important bearing on the cause and treatment of amblyopia, and the role of the eccentric fixation in this case. Visuoscopy is the most frequently used method for determination of eccentric fixation. With traditional visuoscopy, a fixation target is projected onto the patient retina, and the examiner asks to look straight directly at the center of the target. An optometrist then observes the point on the macula used for fixation. This objective test provides clinicians with direct observation of the fixation point of the eye. It requires patients to voluntarily fixate the target and assumes the foveal reflex accurately demarcates the center of the foveal pit. In the end, by having a very simple method to evaluate fixation, it is possible to indirectly evaluate treatment improvement, as eccentric fixation is always associated with reduced visual acuity. So, one may expect that if eccentric fixation in amlyopic eye is found with visuoscopy, then visual acuity should be less than 1.0 (in decimal units). With occlusion or another amblyopia therapy, one would expect both visual acuity and fixation to improve simultaneously, that is fixation would become more central. Consequently, improvement in fixation pattern by treatment is an indirect measurement of improvement of visual acuity. Evaluation of eccentric fixation in the child may be helpful in identifying amblyopia in children prior to measurement of visual acuity. This is very important because the earlier amblyopia is diagnosed – the better the chance of improving visual acuity.

Keywords: amblyopia, eccentric fixation, visual acuity, visuoscopy

Procedia PDF Downloads 158
3972 Adaptation to Repeated Eccentric Exercise Assessed by Double to Single Twitch Ratio

Authors: Damian Janecki, Anna Jaskólska, Jarosław Marusiak, Artur Jaskólski

Abstract:

The aim of this study was to assess double to single twitch ratio after two bouts of eccentric exercise of the elbow flexors. Maximal isometric torque, single and double twitch responses and low-frequency fatigue were assessed on the elbow flexors in 19 untrained male volunteers before, immediately after, 24 and 48 hours following two bouts of eccentric exercise consisted of 30 repetitions of lowering a dumbbell adjusted to ~75% of each individual's maximal isometric torque. Maximal isometric torque and electrically evoked responses decreased significantly in all measurements after the first bout of eccentric exercise (P<0.05). In measurements performed at 24 and 48 hours after the second bout both maximal voluntary isometric torque and electrically evoked contractions were significantly higher than in measurements performed after the fist bout (P<0.05). Although low-frequency fatigue significantly increased up to 48 hours after each bout of eccentric exercise, its values at 24 and 48 hours after the second bout were significantly lower than at respective time points after the first bout (P<0.05). Smaller changes in double to single twitch ratio at 24 and 48 hours after the second bout of eccentric exercise reflects repeated bout effect that confers protection against subsequent exercise-induced muscle damage.

Keywords: biceps brachii, electrical stimulation, lenghtening contractions, repeated bout effect

Procedia PDF Downloads 320
3971 Numerical Simulation of High Strength Steel Hot-Finished Elliptical Hollow Section Subjected to Uniaxial Eccentric Compression

Authors: Zhengyi Kong, Xueqing Wang, Quang-Viet Vu

Abstract:

In this study, the structural behavior of high strength steel (HSS) hot-finished elliptical hollow section (EHS) subjected to uniaxial eccentric compression is investigated. A finite element method for predicting the cross-section resistance of HSS hot-finished EHS is developed using ABAQUS software, which is then verified by comparison with previous experiments. The validated finite element method is employed to carry out parametric studies for investigating the structural behavior of HSS hot-finished EHS under uniaxial eccentric compression and evaluate the current design guidance for HSS hot-finished EHS. Different parameters, such as the radius of the larger and smaller outer diameter of EHS, thickness of EHS, eccentricity, and material property, are considered. The resulting data from 84 finite element models are used to obtain the relationship between the cross-section resistance of HSS hot-finished EHS and cross-section slenderness. It is concluded that current design provisions, such as EN 1993-1-1, BS 5950-1, AS4100, and Gardner et al., are conservative for predicting the HSS hot-finished EHS under uniaxial eccentric compression.

Keywords: hot-finished, elliptical hollow section, uniaxial eccentric compression, finite element method

Procedia PDF Downloads 138
3970 Adjustment and Compensation Techniques for the Rotary Axes of Five-axis CNC Machine Tools

Authors: Tung-Hui Hsu, Wen-Yuh Jywe

Abstract:

Five-axis computer numerical control (CNC) machine tools (three linear and two rotary axes) are ideally suited to the fabrication of complex work pieces, such as dies, turbo blades, and cams. The locations of the axis average line and centerline of the rotary axes strongly influence the performance of these machines; however, techniques to compensate for eccentric error in the rotary axes remain weak. This paper proposes optical (Non-Bar) techniques capable of calibrating five-axis CNC machine tools and compensating for eccentric error in the rotary axes. This approach employs the measurement path in ISO/CD 10791-6 to determine the eccentric error in two rotary axes, for which compensatory measures can be implemented. Experimental results demonstrate that the proposed techniques can improve the performance of various five-axis CNC machine tools by more than 90%. Finally, a result of the cutting test using a B-type five-axis CNC machine tool confirmed to the usefulness of this proposed compensation technique.

Keywords: calibration, compensation, rotary axis, five-axis computer numerical control (CNC) machine tools, eccentric error, optical calibration system, ISO/CD 10791-6

Procedia PDF Downloads 381
3969 Eccentric Loading of CFDST Columns

Authors: Trevor N. Haas, Alexander Koen

Abstract:

Columns have traditionally been constructed of reinforced concrete or structural steel. Much attention was allocated to estimate the axial capacity of the traditional column sections to the detriment of other forms of construction. Other forms of column construction such as Concrete Filled Double Skin Tubes received little research attention, and almost no attention when subjected to eccentric loading. This paper investigates the axial capacity of columns when subjected to eccentric loading. The experimental axial capacities are compared to other established theoretical formulae on concentric loading to determine a possible relationship. The study found a good correlation between the reduction in axial capacity for different column lengths and hollow section ratios.

Keywords: CSDST, CFST, axial capacity, hollow section ratios

Procedia PDF Downloads 339
3968 Effect of Different Muscle Contraction Mode on the Expression of Myostatin, IGF-1, and PGC-1 Alpha Family Members in Human Vastus Lateralis Muscle

Authors: Pejman Taghibeikzadehbadr

Abstract:

Muscle contraction stimulates a transient change of myogenic factors, partly related to the mode of contractions. Here, we assessed the response of Insulin-like growth factor 1Ea (IGF-1Ea), Insulin-like growth factor 1Eb (IGF-1Eb), Insulin-like growth factor 1Ec (IGF-1Ec), Peroxisome proliferator-activated receptor gamma coactivator 1-alpha (PGC1α-1), Peroxisome proliferator-activated receptor gamma coactivator 4-alpha (PGC1α-4), and myostatin to the eccentric Vs the concentric contraction in human skeletal muscle. Ten healthy males were performed an acute eccentric and concentric exercise bout (n = 5 per group). For each contraction type, participants performed 12 sets of 10 repetitions knee extension by the dominant leg. Baseline and post-exercise muscle biopsy were taken 4 weeks before and immediately after experimental sessions from Vastus Lateralis muscle. Genes expression was measured by real-time PCR technique. There was a significant increase in PGC1α-1, PGC1α-4, IGF-1Ea and, IGF-1Eb mRNA after concentric contraction (p ≤ 0.05), while the PGC1α-4 and IGF-1Ec significantly increased after eccentric contraction (p ≤ 0.05). It is intriguing to highlight that; no significant differences between groups were evident for changes in any variables following exercise bouts (p ≥ 0.05). Our results found that concentric and eccentric contractions presented different responses in PGC1α-1, IGF-1Ea, IGF-1Eb, and IGF-1Ec mRNA. However, a similar significant increase in mRNA content was observed in PGC1α-4. Further, no apparent differences could be found between the response of genes to eccentric and concentric contraction.

Keywords: eccentric contraction, concentric contraction, gene expression, PGC-1 alpha, IGF-1 Myostatin

Procedia PDF Downloads 160
3967 Which Tempo On The Bench Press Maximizes 1 Rep Max Growth?

Authors: Aiden Wang, Joseph Marino

Abstract:

In this study, we investigated the impact of different tempo variations on 1-repetition maximum (1RM) growth, focusing on the eccentric, isometric, and concentric phases of the lift. Through a 6-week longitudinal study involving 20 individuals with 1-5 years of barbell training experience, we compared the effects of various tempo schemes on bench press performance. Our results revealed that subjects who performed a tempo bench press with a 3-second eccentric phase, 3-second isometric phase, and explosive concentric phase on a weekly basis experienced the most significant increases in 1RM. Notably, this tempo also led to improved technique and stability during the exercise. Our findings provide valuable insights for strength trainers and coaches seeking to optimize bench press performance and overcome strength plateaus effectively.

Keywords: exercise science, powerlifting, barbell, interventionist, longitudinal study

Procedia PDF Downloads 37
3966 Changing Left Ventricular Hypertrophy After Kidney Transplantation

Authors: Zohreh Rostami, Arezoo Khosravi, Mohammad Nikpoor Aghdam, Mahmood Salesi

Abstract:

Background: Cardiovascular mortality in chronic kidney disease (CKD) and end stage renal disease (ESRD) patients have a strong relationship with baseline or progressive left ventricular hypertrophy (LVH) meanwhile in hemodialysis patients 10% decrement in left ventricular mass was associated with 28% reduction in cardiovascular mortality risk. In consonance with these arguments, we designed a study to measure morphological and functional echocardiographic variations early after transplantation. Method: The patients with normal renal function underwent two advanced echocardiographic studies to examine the structural and functional changes in left ventricular mass before and 3-month after transplantation. Results: From a total of 23 participants 21(91.3%) presented with left ventricular hypertrophy, 60.9% in eccentric and 30.4% in concentric group. Diastolic dysfunction improved in concentric group after transplantation. Both in pre and post transplantation global longitudinal strain (GLS)- average in eccentric group was more than concentric (-17.45 ± 2.75 vs -14.3 ± 3.38 p=0.03) and (-18.08 ± 2.6 vs -16.1 ± 2.7 p= 0.04) respectively. Conclusion: Improvement and recovery of left ventricular function in concentric group was better and sooner than eccentric after kidney transplantation. Although fractional shortening and diastolic function and GLS-4C in pre-transplantation in concentric group was worse than eccentric, but therapeutic response to kidney transplantation in concentric was more and earlier than eccentric group.

Keywords: chronic kidney disease, end stage renal disease, left ventricular hypertrophy, global longitudinal strain

Procedia PDF Downloads 61
3965 A Novel Eccentric Lapping Method with Two Rotatable Lapping Plates for Finishing Cemented Carbide Balls

Authors: C. C. Lv, Y. L. Sun, D. W. Zuo

Abstract:

Cemented carbide balls are usually implemented in industry under the environment of high speed, high temperature, corrosiveness and strong collisions. However, its application is limited due to high fabrication cost, processing efficiency and quality. A novel eccentric lapping method with two rotatable lapping plates was proposed in this paper. A mathematical model was constructed to analyze the influence of each design parameter on this lapping method. To validate this new lapping method, an orthogonal experiment was conducted with cemented carbide balls (YG6). The simulation model was verified and the optimal lapping parameters were derived. The results show that the surface roundness of the balls reaches to 0.65um from 2um in 1 hour using this lapping method. So, using this novel lapping method, it can effectively improve the machining precision and efficiency of cemented carbide balls.

Keywords: cemented carbide balls, eccentric lapping, high precision, lapping tracks, V-groove

Procedia PDF Downloads 394
3964 Building Cardiovascular Fitness through Plyometric Training

Authors: Theresa N. Uzor

Abstract:

The word cardiovascular fitness is a topic of much interest to people of Nigeria, especially during this time, some heart diseases run in families. Cardiovascular fitness is the ability of the heart and lungs to supply-rich blood to the working muscle tissues. This type of fitness is a health-related component of physical fitness that is brought about by sustained physical activity such as plyometric training. Plyometric is a form of advanced fitness training that uses fast muscular contractions to improve power and speed in the sports performance by coaches and athletes. Plyometric training involves a rapid stretching of muscle (eccentric phase) immediately followed by a concentric or shortening action of the same muscle and connective tissue. However, the most basic example of true plyometric training is running and can be safe for a wide variety of populations. This paper focused on building cardiovascular health through Plyometric Training. The centre focus of the article is cardiovascular fitness and plyometric training with factors of cardiovascular fitness. Plyometric training at any age provides multiple benefits even beyond weight control and weight loss, decrease the risk of cardiovascular diseases, stroke, high blood pressure, diabetes, and other diseases, among other benefits of plyometric training to cardiovascular fitness. Participation in plyometric training will increase metabolism of an individual, thereby burning more calories even when at rest and reduces weight is also among the benefits of plyometric training. Some guidelines were recommended for planning plyometric training programme to minimise the chance of injury. With plyometric training in Nigeria, fortune can change for good, especially now that there has been an increase in cardiovascular diseases within the society for great savings would be saved.

Keywords: aerobic, cardiovascular, concentric, stretch-shortening cycle, plyometric

Procedia PDF Downloads 138
3963 Flow inside Micro-Channel Bounded by Superhydrophobic Surface with Eccentric Micro-Grooves

Authors: Yu Chen, Weiwei Ren, Xiaojing Mu, Feng Zhang, Yi Xu

Abstract:

The superhydrophobic surface is widely used to reduce friction for the flow inside micro-channel and can be used to control/manipulate fluid, cells and even proteins in lab-on-chip. Fabricating micro grooves on hydrophobic surfaces is a common method to obtain such superhydrophobic surface. This study utilized the numerical method to investigate the effect of eccentric micro-grooves on the friction of flow inside micro-channel. A detailed parametric study was conducted to reveal how the eccentricity of micro-grooves affects the micro-channel flow under different grooves sizes, channel heights, Reynolds number. The results showed that the superhydrophobic surface with eccentric micro-grooves induces less friction than the counter part with aligning micro-grooves, which means requiring less power for pumps.

Keywords: eccentricity, micro-channel, micro-grooves, superhydrophobic surface

Procedia PDF Downloads 330
3962 Acute Effects of Active Dynamic, Static Stretching and Passive Static Stretching Exercise on Hamstrings Flexibility and Muscle Strength

Authors: Yi Tse Wang, Che Hsiu Chen, Zih Jian Huang, Hon Wen Cheng

Abstract:

Stretching treatments enhanced flexibility. On the other hand, decreases in hamstrings strength have been reported after stretching, especially with static stretching or passive stretching. Stretching has been shown to be more effective than static stretching to improve muscle performance, but a clear consensus for the effect of dynamic stretching on muscle performance has not been achieved. The purpose of this study was to compare the acute effect of a dynamic stretching, static stretching and eccentric exercise protocol on hamstrings stiffness, flexibility and muscle strength. Forty-five healthy active men (height 179.9 cm; weight 71.5 kg; age 22.5 years) were participated in 3 randomly ordered testing sessions: dynamic stretching (DS), active static stretching (ASS), and passive static stretching (PSS). All the stretch were performed 30 seconds and repeated 6 times. There was a 30-second interval between repetitions. The outcome measures were isokinetic concentric contraction (60°/s), eccentric contraction (30°/s) peak torque, muscle flexibility after stretching. The results showed that the muscle flexibility (3.6%, 3.9% and 1.59%, respectively) increased significantly after DS, PSS and ASS. Hamstring isokinetic concentric peak torque (-6.4%, -8.0% and -5.8%, respectively) and eccentric peak torque (-5.8%, -4.5% and -5.4%, respectively) decreased significantly after DS, PSS and ASS. Hence, although the stretching protocols improve hamstrings flexibility immediately, reduced hamstring muscle eccentric and concentric peak torque.

Keywords: hamstrings injury, warm-up, muscle performance, muscle stretching

Procedia PDF Downloads 383
3961 Effect of Two Bouts of Eccentric Exercise on Knee Flexors Changes in Muscle-Tendon Lengths

Authors: Shang-Hen Wu, Yung-Chen Lin, Wei-Song Chang, Ming-Ju Lin

Abstract:

This study investigated whether the repeated bout effect (RBE) of knee flexors (KF) eccentric exercise would be changed in muscle-tendon lengths. Eight healthy university male students used their KF of non-dominant leg and performed a bout of 60 maximal isokinetic (30°/s) eccentric contractions (MaxECC1). A week after MaxECC1, all subjects used the same KF to perform a subsequent bout of MaxECC2. Changes in maximal isokinetic voluntary contraction torque (MVC-CON), muscle soreness (SOR), relaxed knee joint angle (RANG), leg circumference (CIR), and ultrasound images (UI; muscle-tendon length and muscle angle) were measured before, immediately after, 1-5 days after each bout. Two-way ANOVA was used to analyze all the dependent variables. After MaxECC1, all the dependent variables (e.g. MVC-CON: ↓30%, muscle-tendon length: ↑24%, muscle angle: ↑15%) showed significantly change. Following MaxECC2, all the above dependent variables (e.g. MVC-CON:↓21%, tendon length: ↑16%, muscle angle: ↑6%) were significantly smaller than those of MaxECC1. These results of this study found that protective effect conferred by MaxECC1 against MaxECC2, and changes in muscle damage indicators, muscle-tendon length and muscle angle following MaxECC2 were smaller than MaxECC1. Thus, the amount of shift of muscle-tendon length and muscle angle was related to the RBE.

Keywords: eccentric exercise, maximal isokinetic voluntary contraction torque, repeated bout effect, ultrasound

Procedia PDF Downloads 330
3960 Effect of Submaximal Eccentric versus Maximal Isometric Contraction on Delayed Onset Muscle Soreness

Authors: Mohamed M. Ragab, Neveen A. Abdel Raoof, Reham H. Diab

Abstract:

Background: Delayed onset muscle soreness (DOMS) is the most common symptom when ordinary individuals and athletes are exposed to unaccustomed physical activity, especially eccentric contraction which impairs athletic performance, ordinary people work ability and physical functioning. A multitude of methods have been investigated to reduce DOMS. One of the valuable method to control DOMS is repeated bout effect (RBE) as a prophylactic method. Purpose: To compare the repeated bout effect of submaximal eccentric contraction versus maximal isometric contraction on induced DOMS. Methods: Sixty normal male volunteers were assigned randomly into three groups of equal number: Group (A) “first study group”: 20 subjects received submaximal eccentric contraction on non-dominant elbow flexors as prophylactic exercise. Group (B) “second study group”: 20 subjects received maximal isometric contraction on non-dominant elbow flexors as prophylactic exercise. Group (C) “control group”: 20 subjects did not receive any prophylactic exercise. Maximal isometric contraction peak torque of elbow flexors and patient related elbow evaluation (PREE) scale were measured for each subject 3 times before, immediately after and 48 hours after induction of DOMS. Results: Post-hoc test for maximal isometric peak torque and PREE scale immediately and 48 hours after induction of DOMS revealed that group (A) and group (B) resulted in significant decrease in maximal isometric strength loss and elbow pain and disability rather than control group (C), but submaximal eccentric group (A) was more effective than maximal isometric group (B) as it showed more rapid recovery of functional strength and less degrees of elbow pain and disability. Conclusion: Both submaximal eccentric contraction and maximal isometric contraction were effective in prevention of DOMS but submaximal eccentric contraction had the greatest protective effect.

Keywords: delayed onset muscle soreness, maximal isometric peak torque, patient related elbow evaluation scale, repeated bout effect

Procedia PDF Downloads 364
3959 Effect of Velocity Slip on Two Phase Flow in an Eccentric Annular Region

Authors: Umadevi B., Dinesh P. A., Indira. R., Vinay C. V.

Abstract:

A mathematical model is developed to study the simultaneous effects of particle drag and slip parameter on the velocity as well as rate of flow in an annular cross sectional region bounded by two eccentric cylinders. In physiological flows this phenomena can be observed in an eccentric catheterized artery with inner cylinder wall is impermeable and outer cylinder wall is permeable. Blood is a heterogeneous fluid having liquid phase consisting of plasma in which a solid phase of suspended cells and proteins. Arterial wall gets damaged due to aging and lipid molecules get deposited between damaged tissue cells. Blood flow increases towards the damaged tissues in the artery. In this investigation blood is modeled as two phase fluid as one is a fluid phase and the other is particulate phase. The velocity of the fluid phase and rate of flow are obtained by transforming eccentric annulus to concentric annulus with the conformal mapping. The formulated governing equations are analytically solved for the velocity and rate of flow. The numerical investigations are carried out by varying eccentricity parameter, slip parameter and drag parameter. Enhancement of slip parameter signifies loss of fluid then the velocity and rate of flow will be decreased. As particulate drag parameter increases then the velocity as well as rate flow decreases. Eccentricity facilitates transport of more fluid then the velocity and rate of flow increases.

Keywords: catheter, slip parameter, drag parameter, eccentricity

Procedia PDF Downloads 522
3958 Structural Behavior of Composite Hollow RC Column under Combined Loads

Authors: Abdul Qader Melhm, Hussein Elrafidi

Abstract:

This paper is dealing with studying the structural behavior of a steel-composite hollow reinforced concrete (RC) column model under combined eccentric loading. The composite model consists of an inner steel tube surrounded via a concrete core with longitudinal and circular transverse reinforcement. The radius of gyration according to American and Euro specifications be calculated, in order to calculate the thinnest ratio for this type of composite column model, in addition to the flexural rigidity. Formulas for interaction diagram is given for this type of model, which is a general loading conditions in which an element is exposed to an axial load with bending at the same time. The structural capacity of this model, elastic, plastic loads and strains will be computed and compared with experimental results. The total eccentric axial load of the column model is calculated based on the effective length KL available from several relationships provided in the paper. Furthermore, the inner tube experiences buckling failure after reaching its maximum strength will be investigated.

Keywords: column, composite, eccentric, inner tube, interaction, reinforcement

Procedia PDF Downloads 192
3957 Effect of Low Level Laser for Athletic Achilles Tendinopathy: A Systematic Review

Authors: Sameh Eldaly, Rola Essam

Abstract:

Objective: The purpose of this study was to determine the benefits of low-level laser therapy for Athletic Achilles Tendinopathy. Data sources: Search strategies were conducted on 2 Randomized control trial and one pilot study. Results: three trials (103 participants) were analyzed. Laser therapy associated to eccentric exercises, when compared to eccentric exercises and placebo, had low to very low certainty of evidence in pain and function assessment. Conclusion: those three trials evidenced low to very low effect of LLLT, and the results are insufficient to support the routine use LLLT for Achilles tendinopathy.

Keywords: achilles tendinopathy, evidence-based, low-level laser therapy, review

Procedia PDF Downloads 80
3956 The Effects of Chamomile on Serum Levels of Inflammatory Indexes to a Bout of Eccentric Exercise in Young Women

Authors: K. Azadeh, M. Ghasemi, S. Fazelifar

Abstract:

Aim: Changes in stress hormones can be modify response of immune system. Cortisol as the most important body corticosteroid is anti-inflammatory and immunosuppressive hormone. Normal levels of cortisol in humans has fluctuated during the day, In other words, cortisol is released periodically, and regulate through the release of ACTH circadian rhythm in every day. Therefore, the aim of this study was to determine the effects of Chamomile on serum levels of inflammatory indexes to a bout of eccentric exercise in young women. Methodology: 32 women were randomly divided into 4 groups: high dose of Chamomile, low dose of Chamomile, ibuprofen and placebo group. Eccentric exercise included 5 set and rest period between sets was 1 minute. For this purpose, subjects warm up 10 min and then done eccentric exercise. Each participant completed 15 repetitions with optional 20 kg weight or until can’t continue moving. When the subject was no longer able to continue to move, immediately decreased 5 kg from the weight and the protocol continued until cause exhaustion or complete 15 repetitions. Also, subjects received specified amount of ibuprofen and Chamomile capsules in target groups. Blood samples in 6 stages (pre of starting pill, pre of exercise protocol, 4, 24, 48 and 72 hours after eccentric exercise) was obtained. The levels of cortisol and adrenocorticotropic hormone levels were measured by ELISA way. K-S test to determine the normality of the data and analysis of variance for repeated measures was used to analyze the data. A significant difference in the p < 0/05 accepted. Results: The results showed that Individual characteristics including height, weight, age and body mass index were not significantly different among the four groups. Analyze of data showed that cortisol and ACTH basic levels significantly decreased after supplementation consumption, but then gradually significantly increased in all stages of post exercise. In High dose of Chamomile group, increasing tendency of post exercise somewhat less than other groups, but not to a significant level. The inter-group analysis results indicate that time effect had a significant impact in different stages of the groups. Conclusion: The results of this study, one session of eccentric exercise increased cortisol and ACTH hormone. The results represent the effect of high dose of Chamomile in the prevention and reduction of increased stress hormone levels. As regards use of medicinal plants and ibuprofen as a pain medication and inflammation has spread among athletes and non-athletes, the results of this research can provide information about the advantages and disadvantages of using medicinal plants and ibuprofen.

Keywords: chamomile, inflammatory indexes, eccentric exercise, young girls

Procedia PDF Downloads 417
3955 Mechanical Responses to Hip Versus Knee Induced Muscle Fatigue in Patellofemoral Pain Syndrome

Authors: Eman Ahmed Ahmed, Ghada Abdelmoneim Mohamed, Hamada Ahmed Hamada, Nagui Sobhi Nassif

Abstract:

Impaired skeletal muscle endurance may be an important causal factor in the development of patellofemoral pain syndrome (PFPS). However, there is lack of information regarding the effect of hip versus knee muscle fatigue on isokinetic parameters, and myoelectric activity of hip and knee muscles in these patients. Purpose: The study was conducted to investigate the effect of hip abductors versus knee extensors fatigue protocol on knee proprioception, hip and knee muscle strength and their myoelectric activity in patients with PFPS. Methods: Fifteen female patients with PFPS participated in the study. They were tested randomly under two fatiguing conditions; hip abductors and knee extensors fatigue protocols. Isolated muscle fatigue of two muscles was induced isokinetically on the affected side in a two separate sessions with a rest interval of at least three days. After determining peak torque, patients performed continuous maximal concentric-eccentric contraction of the selected muscle until the torque output dropped below 50% of peak torque value for 3 consecutive repetitions. Knee proprioception, eccentric hip abductors' peak torque, eccentric knee extensors' peak torque, EMG ratio of vastus medialis obliquus (VMO) / vastus lateralis (VL), and EMG activity of gluteus medius (GM) muscle, were recorded before and immediately after each fatigue protocol using the Biodex Isokinetic system and EMG Myosystem. Results: Two-way within subject MANOVA revealed that eccentric knee extensors’ peak torque decreased significantly after hip abductors fatigue protocol compared to pre fatigue condition (p<0.05). On the other hand, there was no statistically significant difference in the eccentric hip abductors’ peak torque after admitting knee extensors fatigue protocol (p > 0.05). Moreover, no significant difference was found in knee proprioception, EMG ratio of VMO/VL, and EMG activity of GM muscle, after either hip or knee fatigue protocol (p>0.05). Conclusion: A hip focused rehabilitation program may be beneficial in improving knee function through correcting faulty kinematics and hence decrease knee loading in patients with PFPS.

Keywords: electromyography, knee proprioception, mechanical responses, muscle fatigue, patellofemoral pain syndrome

Procedia PDF Downloads 310
3954 The Effect of Vertical Shear-link in Improving the Seismic Performance of Structures with Eccentrically Bracing Systems

Authors: Mohammad Reza Baradaran, Farhad Hamzezarghani, Mehdi Rastegari Ghiri, Zahra Mirsanjari

Abstract:

Passive control methods can be utilized to build earthquake resistant structures, and also to strengthen the vulnerable ones. One of the most effective, yet simple passive control methods is the use of vertical shear-links (VSL) in systems with eccentric bracing. In fact, vertical shear-links dissipate the earthquake energy and act like a ductile fuse. In this paper, we studied the effect of this system in increasing the ductility and energy dissipation and also modeled the behavior of this type of eccentric bracing, and compared the hysteresis diagram of the modeled samples with the laboratory samples. We studied several samples of frames with vertical shear-links in order to assess the behavior of this type of eccentric bracing. Each of these samples was modeled in finite element software ANSYS 9.0, and was analyzed under the static cyclic loading. It was found that vertical shear-links have a more stable hysteresis loops. Another analysis showed that using honeycomb beams as the horizontal beam along with steel reinforcement has no negative effect on the hysteresis behavior of the sample.

Keywords: vertical shear-link, passive control, cyclic analysis, energy dissipation, honeycomb beam

Procedia PDF Downloads 495
3953 Simulation of Nano Drilling Fluid in an Extended Reach Well

Authors: Lina Jassim, Robiah Yunus, , Amran Salleh

Abstract:

Since nano particles have been assessed as thermo stabilizer, rheology enhancer, and ecology safer, nano drilling fluid can be utilized to overcome the complexity of hole cleaning in highly deviated interval of an extended reach wells. The eccentric annular flow is a flow with special considerations; it forms a vital part of drilling fluid flow analysis in an extended reach wells. In this work eccentric, dual phase flow (different types of rock cuttings with different size were blended with nano fluid) through horizontal well (an extended reach well) are simulated with the help of CFD, Fluent package. In horizontal wells flow occurs in an adverse pressure gradient condition, that makes the particle inside it susceptible to reversed flow. Thus the flow has to be analyzed in a three dimensional manner. Moreover the non-Newtonian behavior of the nano fluid makes the problem really challenging in numerical and physical aspects. The primary objective of the work is to establish a relationship between different flow characteristics with the speed of inner wall rotation. The nano fluid flow characteristics include swirl of flow and its effect on wellbore cleaning ability , wall shear stress and its effect on fluid viscosity to suspend and carry the rock cuttings, axial velocity and its effect on transportation of rock cuttings to the wellbore surface, finally pressure drop and its effect on managed of drilling pressure. The importance of eccentricity of the inner cylinder has to be analyzed as a part of it. Practical horizontal well flows contain a good amount of particles (rock cuttings) with moderate axial velocity, which verified nano drilling fluid ability of carrying and transferring cuttings particles in the highly deviated eccentric annular flow is also of utmost importance.

Keywords: Non-Newtonian, dual phase, eccentric annular, CFD

Procedia PDF Downloads 434
3952 Effect of Kinesio Taping on Anaerobic Power and Maximum Oxygen Consumption after Eccentric Exercise

Authors: Disaphon Boobpachat, Nuttaset Manimmanakorn, Apiwan Manimmanakorn, Worrawut Thuwakum, Michael J. Hamlin

Abstract:

Objectives: To evaluate effect of kinesio tape compared to placebo tape and static stretching on recovery of anaerobic power and maximal oxygen uptake (Vo₂max) after intensive exercise. Methods: Thirty nine untrained healthy volunteers were randomized to 3 groups for each intervention: elastic tape, placebo tape and stretching. The participants performed intensive exercise on the dominant quadriceps by using isokinetic dynamometry machine. The recovery process was evaluated by creatine kinase (CK), pressure pain threshold (PPT), muscle soreness scale (MSS), maximum voluntary contraction (MVC), jump height, anaerobic power and Vo₂max at baseline, immediately post-exercise and post-exercise day 1, 2, 3 and 7. Results: The kinesio tape, placebo tape and stretching groups had significant changes of PPT, MVC, jump height at immediately post-exercise compared to baseline (p < 0.05), and changes of MSS, CK, anaerobic power and Vo₂max at day 1 post-exercise compared to baseline (p < 0.05). There was no significant difference of those outcomes among three groups. Additionally, all experimental groups had little effects on anaerobic power and Vo₂max compared to baseline and compared among three groups (p > 0.05). Conclusion: Kinesio tape and stretching did not improve recovery of anaerobic power and Vo₂max after eccentric exercise compared to placebo tape.

Keywords: stretching, eccentric exercise, Wingate test, muscle soreness

Procedia PDF Downloads 130
3951 Effects of Lower and Upper Body Plyometric Training on Electrocardiogram Parameters of University Athletes

Authors: T. N. Uzor, C. O. Akosile, G. O. Emeahara

Abstract:

Plyometric training is a form of specialised strength training that uses fast muscular contractions to improve power and speed in sports conditioning by coaches and athletes. Despite its useful role in sports conditioning programme, the information about plyometric training on the athletes cardiovascular health especially Electrocardiogram (ECG) has not been established in the literature. The purpose of the study was to determine the effects of lower and upper body plyometric training on ECG of athletes. The study was guided by three null hypotheses. Quasi–experimental research design was adopted for the study. Seventy-two university male athletes constituted the population of the study. Thirty male athletes aged 18 to 24 years volunteered to participate in the study, but only twenty-three completed the study. The volunteered athletes were apparently healthy, physically active and free of any lower and upper extremity bone injuries for past one year and they had no medical or orthopedic injuries that may affect their participation in the study. Ten subjects were purposively assigned to one of the three groups: lower body plyometric training (LBPT), upper body plyometric training (UBPT), and control (C). Training consisted of six plyometric exercises: lower (ankle hops, squat jumps, tuck jumps) and upper body plyometric training (push-ups, medicine ball-chest throws and side throws) with moderate intensity. The general data were collated and analysed using Statistical Package for Social Science (SPSS version 22.0). The research questions were answered using mean and standard deviation, while paired samples t-test was also used to test for the hypotheses. The results revealed that athletes who were trained using LBPT had reduced ECG parameters better than those in the control group. The results also revealed that athletes who were trained using both LBPT and UBPT indicated lack of significant differences following ten weeks plyometric training than those in the control group in the ECG parameters except in Q wave, R wave and S wave (QRS) complex. Based on the findings of the study, it was recommended among others that coaches should include both LBPT and UBPT as part of athletes’ overall training programme from primary to tertiary institution to optimise performance as well as reduce the risk of cardiovascular diseases and promotes good healthy lifestyle.

Keywords: concentric, eccentric, electrocardiogram, plyometric

Procedia PDF Downloads 142
3950 Behavior of Square Reinforced-Concrete Columns Strengthened with Carbon Fiber Reinforced Polymers under Eccentric Loading

Authors: Dana J. Abed, Mu'tasim S. Abdel-Jaber, Nasim K. Shatarat

Abstract:

In this paper, an experimental study on twelve square columns was conducted to investigate the influence of cross-sectional size on axial compressive capacity of carbon fiber reinforced polymers (CFRP) wrapped square reinforced concrete (RC) short columns subjected to eccentric loadings. The columns were divided into three groups with three cross sections (200×200×1200, 250×250×1500 and 300×300×1800 mm). Each group was tested under two different eccentricities: 10% and 20% of the width of samples measured from the center of the column cross section. Four columns were developed in each arrangement. Two columns in each category were left unwrapped as control samples, and two were wrapped with one layer CFRP perpendicular to the specimen surface. In general; CFRP sheets has enhanced the performance of the strengthened columns compared to the control columns. It was noticed that the percentage of compressive capacity enhancement was decreased by increasing the cross-sectional size, and increasing loading eccentricity generally leads to reduced load bearing capacity in columns. In the same group specimens, when the eccentricity increased the percentage of enhancement in load carrying capacity was increased. The study concludes that the optimum use of the CFRP sheets for axial strength enhancement is for smaller cross-section columns under higher eccentricities.

Keywords: CFRP, columns, eccentric loading, cross-sectional

Procedia PDF Downloads 175
3949 Experimental and Numerical Study of Ultra-High-Performance Fiber-Reinforced Concrete Column Subjected to Axial and Eccentric Loads

Authors: Chengfeng Fang, Mohamed Ali Sadakkathulla, Abdul Sheikh

Abstract:

Ultra-high-performance fiber reinforced concrete (UHPFRC) is a specially formulated cement-based composite characterized with an ultra-high compressive strength (fc = 240 MPa) and a low water-cement ratio (W/B= 0.2). With such material characteristics, UHPFRC is favored for the design and constructions of structures required high structural performance and slender geometries. Unlike conventional concrete, the structural performance of members manufactured with UHPFRC has not yet been fully studied, particularly, for UHPFRC columns with high slenderness. In this study, the behaviors of slender UHPFRC columns under concentric or eccentric load will be investigated both experimentally and numerically. Four slender UHPFRC columns were tested under eccentric loads with eccentricities, of 0 mm, 35 mm, 50 mm, and 85 mm, respectively, and one UHPFRC beam was tested under four-point bending. Finite element (FE) analysis was conducted with concrete damage plasticity (CDP) modulus to simulating the load-middle height or middle span deflection relationships and damage patterns of all UHPFRC members. Simulated results were compared against the experimental results and observation to gain the confidence of FE model, and this model was further extended to conduct parametric studies, which aim to investigate the effects of slenderness regarding failure modes and load-moment interaction relationships. Experimental results showed that the load bearing capacities of the slender columns reduced with an increase in eccentricity. Comparisons between load-middle height and middle span deflection relationships as well as damage patterns of all UHPFRC members obtained both experimentally and numerically demonstrated high accuracy of the FE simulations. Based on the available FE model, the following parametric study indicated that a further increase in the slenderness of column resulted in significant decreases in the load-bearing capacities, ductility index, and flexural bending capacities.

Keywords: eccentric loads, ductility index, RC column, slenderness, UHPFRC

Procedia PDF Downloads 126
3948 Changes in Vocational Teacher Training in Hungary: Challenges and Possibilities

Authors: Anetta Bacsa-Bán

Abstract:

The training of vocational education teachers in Hungary was a special training system before the Bologna system, but under the influence of the Bologna system, the structure and content of the training changed significantly. The training of vocational teachers, including engineering teachers and vocational trainers, is considerably different when compared to the training of public education teachers. This study aims to present these differences and peculiarities, problems and issues of the training as well as to outline the possibilities of further development. During the study, the following methods were implemented: empirical research among students and graduates of vocational teacher training, as well as analysis of the relevant literature. The study summarizes the research and theoretical results related to vocational education and training (VET) teacher training over the past 15 years, with the aim of developing the training and mapping new directions in the field.

Keywords: vocational teacher, technical instructors, technical vocational instructors, theoretical aspects

Procedia PDF Downloads 256
3947 Exploring the Need to Study the Efficacy of VR Training Compared to Traditional Cybersecurity Training

Authors: Shaila Rana, Wasim Alhamdani

Abstract:

Effective cybersecurity training is of the utmost importance, given the plethora of attacks that continue to increase in complexity and ubiquity. VR cybersecurity training remains a starkly understudied discipline. Studies that evaluated the effectiveness of VR cybersecurity training over traditional methods are required. An engaging and interactive platform can support knowledge retention of the training material. Consequently, an effective form of cybersecurity training is required to support a culture of cybersecurity awareness. Measurements of effectiveness varied throughout the studies, with surveys and observations being the two most utilized forms of evaluating effectiveness. Further research is needed to evaluate the effectiveness of VR cybersecurity training and traditional training. Additionally, research for evaluating if VR cybersecurity training is more effective than traditional methods is vital. This paper proposes a methodology to compare the two cybersecurity training methods and their effectiveness. The proposed framework includes developing both VR and traditional cybersecurity training methods and delivering them to at least 100 users. A quiz along with a survey will be administered and statistically analyzed to determine if there is a difference in knowledge retention and user satisfaction. The aim of this paper is to bring attention to the need to study VR cybersecurity training and its effectiveness compared to traditional training methods. This paper hopes to contribute to the cybersecurity training field by providing an effective way to train users for security awareness. If VR training is deemed more effective, this could create a new direction for cybersecurity training practices.

Keywords: virtual reality cybersecurity training, VR cybersecurity training, traditional cybersecurity training

Procedia PDF Downloads 212