Search results for: power loss analysis
32466 Numerical Simulation of Two-Phase Flows Using a Pressure-Based Solver
Authors: Lei Zhang, Jean-Michel Ghidaglia, Anela Kumbaro
Abstract:
This work focuses on numerical simulation of two-phase flows based on the bi-fluid six-equation model widely used in many industrial areas, such as nuclear power plant safety analysis. A pressure-based numerical method is adopted in our studies due to the fact that in two-phase flows, it is common to have a large range of Mach numbers because of the mixture of liquid and gas, and density-based solvers experience stiffness problems as well as a loss of accuracy when approaching the low Mach number limit. This work extends the semi-implicit pressure solver in the nuclear component CUPID code, where the governing equations are solved on unstructured grids with co-located variables to accommodate complicated geometries. A conservative version of the solver is developed in order to capture exactly the shock in one-phase flows, and is extended to two-phase situations. An inter-facial pressure term is added to the bi-fluid model to make the system hyperbolic and to establish a well-posed mathematical problem that will allow us to obtain convergent solutions with refined meshes. The ability of the numerical method to treat phase appearance and disappearance as well as the behavior of the scheme at low Mach numbers will be demonstrated through several numerical results. Finally, inter-facial mass and heat transfer models are included to deal with situations when mass and energy transfer between phases is important, and associated industrial numerical benchmarks with tabulated EOS (equations of state) for fluids are performed.Keywords: two-phase flows, numerical simulation, bi-fluid model, unstructured grids, phase appearance and disappearance
Procedia PDF Downloads 39332465 Harmonic Assessment and Mitigation in Medical Diagonesis Equipment
Authors: S. S. Adamu, H. S. Muhammad, D. S. Shuaibu
Abstract:
Poor power quality in electrical power systems can lead to medical equipment at healthcare centres to malfunction and present wrong medical diagnosis. Equipment such as X-rays, computerized axial tomography, etc. can pollute the system due to their high level of harmonics production, which may cause a number of undesirable effects like heating, equipment damages and electromagnetic interferences. The conventional approach of mitigation uses passive inductor/capacitor (LC) filters, which has some drawbacks such as, large sizes, resonance problems and fixed compensation behaviours. The current trends of solutions generally employ active power filters using suitable control algorithms. This work focuses on assessing the level of Total Harmonic Distortion (THD) on medical facilities and various ways of mitigation, using radiology unit of an existing hospital as a case study. The measurement of the harmonics is conducted with a power quality analyzer at the point of common coupling (PCC). The levels of measured THD are found to be higher than the IEEE 519-1992 standard limits. The system is then modelled as a harmonic current source using MATLAB/SIMULINK. To mitigate the unwanted harmonic currents a shunt active filter is developed using synchronous detection algorithm to extract the fundamental component of the source currents. Fuzzy logic controller is then developed to control the filter. The THD without the active power filter are validated using the measured values. The THD with the developed filter show that the harmonics are now within the recommended limits.Keywords: power quality, total harmonics distortion, shunt active filters, fuzzy logic
Procedia PDF Downloads 47932464 A Digital Pulse-Width Modulation Controller for High-Temperature DC-DC Power Conversion Application
Authors: Jingjing Lan, Jun Yu, Muthukumaraswamy Annamalai Arasu
Abstract:
This paper presents a digital non-linear pulse-width modulation (PWM) controller in a high-voltage (HV) buck-boost DC-DC converter for the piezoelectric transducer of the down-hole acoustic telemetry system. The proposed design controls the generation of output signal with voltage higher than the supply voltage and is targeted to work under high temperature. To minimize the power consumption and silicon area, a simple and efficient design scheme is employed to develop the PWM controller. The proposed PWM controller consists of serial to parallel (S2P) converter, data assign block, a mode and duty cycle controller (MDC), linearly PWM (LPWM) and noise shaper, pulse generator and clock generator. To improve the reliability of circuit operation at higher temperature, this design is fabricated with the 1.0-μm silicon-on-insulator (SOI) CMOS process. The implementation results validated that the proposed design has the advantages of smaller size, lower power consumption and robust thermal stability.Keywords: DC-DC power conversion, digital control, high temperatures, pulse-width modulation
Procedia PDF Downloads 39532463 Analysis of the Relationship between the Old Days Hospitalized with Economic Lost Top Ten Age Productive Disease in Hospital Inpatient Inche Abdul Moeis Samarinda, Indonesia
Authors: Tri Murti Tugiman, Awalyya Fasha
Abstract:
This research aims to analyze the magnitude of the economic losses incurred as a result of a person suffering from a particular disease of the ten highest in the productive age diseases in Hospitals Inche Abdul Moeis Samarinda. This research was a descriptive survey research and a secondary data analysis. For the analysis of economic losses populations used are all in patients who suffer from the 10 highest diseases in the productive age in hospitals IA Moeis Samarinda in 2011. Sampling was performed by using a stratified random sampling with samples of 77 people. Research results indicate that the direct cost community incurred to obtain medical services in hospitals IA Moeis is IDR 74437520. The amount of indirect costs incurred during service in a community hospital is IDR 10562000. The amount lost due to sickness fee is IDR 5377800. The amount of economic lost people to obtain medical services in hospitals IA Moeis is IDR 90377320. The number of days of hospitalization was as much as 171 respondents throughout the day. This study suggests the economic loss could be prevented by changes in the lifestyle of the people who clean and healthy along with the following insurance.Keywords: hospitalized, economic lost, productive age diseases, secondary data analysis
Procedia PDF Downloads 48032462 Islanding Detection of Wind Turbine by Rate of Change of Frequency (ROCOF) and Rate of change of Power (ROCOP) Method
Authors: Vipulkumar Jagodana
Abstract:
Recently the use of renewable sources has increased, these sources include fuel cell, photo voltaic, and wind turbine. Islanding occurs when one portion of grid is isolated from remaining grid. Use of the renewable sources can provide continuous power to isolated portion in islanding condition. One of the common renewable sources is wind generation using wind turbine. The efficiency of wind generation can be increased in combination with conventional sources. When islanding occurs, few parameters change which may be frequency, voltage, active power, and harmonics. According to large change in one of these parameters islanding is detected. In this paper, two passive methods Rate of Change of Frequency (ROCOF) and Rate of change of Power (ROCOP) have been implemented for islanding detection of small wind-turbine. Islanding detection of both methods have been simulated in PSCAD. Simulation results show at different islanding inception angle response of ROCOF and ROCOP.Keywords: islanding, adopted methods, PSCAD simulation, comparison
Procedia PDF Downloads 22532461 A 5-V to 30-V Current-Mode Boost Converter with Integrated Current Sensor and Power-on Protection
Authors: Jun Yu, Yat-Hei Lam, Boris Grinberg, Kevin Chai Tshun Chuan
Abstract:
This paper presents a 5-V to 30-V current-mode boost converter for powering the drive circuit of a micro-electro-mechanical sensor. The design of a transconductance amplifier and an integrated current sensing circuit are presented. In addition, essential building blocks for power-on protection such as a soft-start and clamp block and supply and clock ready block are discussed in details. The chip is fabricated in a 0.18-μm CMOS process. Measurement results show that the soft-start and clamp block can effectively limit the inrush current during startup and protect the boost converter from startup failure.Keywords: boost converter, current sensing, power-on protection, step-up converter, soft-start
Procedia PDF Downloads 101932460 Bright–Dark Pulses in Nonlinear Polarisation Rotation Based Erbium-Doped Fiber Laser
Authors: R. Z. R. R. Rosdin, N. M. Ali, S. W. Harun, H. Arof
Abstract:
We have experimentally demonstrated bright-dark pulses in a nonlinear polarization rotation (NPR) based mode-locked Erbium-doped fiber laser (EDFL) with a long cavity configuration. Bright–dark pulses could be achieved when the laser works in the passively mode-locking regime and the net group velocity dispersion is quite anomalous. The EDFL starts to generate a bright pulse train with degenerated dark pulse at the mode-locking threshold pump power of 35.09 mW by manipulating the polarization states of the laser oscillation modes using a polarization controller (PC). A split bright–dark pulse is generated when further increasing the pump power up to 37.95 mW. Stable bright pulses with no obvious evidence of a dark pulse can also be generated when further adjusting PC and increasing the pump power up to 52.19 mW. At higher pump power of 54.96 mW, a new form of bright-dark pulse emission was successfully identified with the repetition rate of 29 kHz. The bright and dark pulses have a duration of 795.5 ns and 640 ns, respectively.Keywords: Erbium-doped fiber laser, nonlinear polarization rotation, bright-dark pulse, photonic
Procedia PDF Downloads 52432459 Increasing Power Transfer Capacity of Distribution Networks Using Direct Current Feeders
Authors: Akim Borbuev, Francisco de León
Abstract:
Economic and population growth in densely-populated urban areas introduce major challenges to distribution system operators, planers, and designers. To supply added loads, utilities are frequently forced to invest in new distribution feeders. However, this is becoming increasingly more challenging due to space limitations and rising installation costs in urban settings. This paper proposes the conversion of critical alternating current (ac) distribution feeders into direct current (dc) feeders to increase the power transfer capacity by a factor as high as four. Current trends suggest that the return of dc transmission, distribution, and utilization are inevitable. Since a total system-level transformation to dc operation is not possible in a short period of time due to the needed huge investments and utility unreadiness, this paper recommends that feeders that are expected to exceed their limits in near future are converted to dc. The increase in power transfer capacity is achieved through several key differences between ac and dc power transmission systems. First, it is shown that underground cables can be operated at higher dc voltage than the ac voltage for the same dielectric stress in the insulation. Second, cable sheath losses, due to induced voltages yielding circulation currents, that can be as high as phase conductor losses under ac operation, are not present under dc. Finally, skin and proximity effects in conductors and sheaths do not exist in dc cables. The paper demonstrates that in addition to the increased power transfer capacity utilities substituting ac feeders by dc feeders could benefit from significant lower costs and reduced losses. Installing dc feeders is less expensive than installing new ac feeders even when new trenches are not needed. Case studies using the IEEE 342-Node Low Voltage Networked Test System quantify the technical and economic benefits of dc feeders.Keywords: DC power systems, distribution feeders, distribution networks, power transfer capacity
Procedia PDF Downloads 12832458 Solar and Wind Energy Potential Study of Lower Sindh, Pakistan for Power Generation
Authors: M. Akhlaque Ahmed, Sidra A. Shaikh, Maliha A. Siddiqui
Abstract:
Global and diffuse solar radiation on horizontal surface of Lower Sindh, namely Karachi, Hyderabad, Nawabshah were carried out using sunshine hour data of the area to assess the feasibility of solar energy utilization for power generation in Sindh province. The results obtained show a large variation in the direct and diffuse component of solar radiation in summer and winter months in Lower Sindh (50% direct and 50% diffuse for Karachi and Hyderabad). In Nawabshah area, the contribution of diffuse solar radiation is low during the monsoon months, July and August. The KT value of Nawabshah indicates a clear sky throughout almost the entire year. The percentage of diffuse radiation does not exceed more than 20%. In Nawabshah, the appearance of cloud is rare even during the monsoon months. The estimated values indicate that Nawabshah has high solar potential, whereas Karachi and Hyderabad have low solar potential. During the monsoon months the Lower part of Sindh can utilize the hybrid system with wind power. Near Karachi and Hyderabad, the wind speed ranges between 6.2 m/sec to 6.9 m/sec. A wind corridor exists near Karachi, Hyderabad, Gharo, Keti Bander and Shah Bander. The short fall of solar can be compensated by wind because in the monsoon months of July and August, wind speeds are higher in the Lower region of Sindh.Keywords: hybrid power system, lower Sindh, power generation, solar and wind energy potential
Procedia PDF Downloads 25232457 Transition from Early Education to Pre-School Education in Children with Hearing Loss in Turkey: Problems and Recommendations
Authors: Şule Yanık, Emel Ertürk-Mustul, Zerrin Turan, Hasan Gürgür
Abstract:
It is known that there are policies that will support the early special education (ESE) for children requiring special care including the children with hearing loss (CHL) in many countries that give importance to early childhood (0-6 years) education, accordingly ESE services have been gradually increasing and these services provide positive contributions to the child and family. These services begin with medical diagnostics, provision of the use of assistive technologies for hearing and the orientation of children towards early education program (EEP) for the CHL. In 0-3 years of age EEP, education and support services are provided to the children and their families. In 3-6 years of age, children are supported in a pre-school education program (PSE) in which their peers and teachers are present. Therefore, the children with hearing loss and their families are going through a series of medical, educational and social transition process after diagnosed with hearing loss. Depending on their age and development, CHL also go through a transition period from hospital to home, from home to EEP and from EEP to PSE. It is seen that there is no legal regulation regarding the transition process in Turkey and hence different processes have been carried out in the transition process from EEP to PSE. The aim of this study is to reveal the problems confronted by the CHL during the transition period from EEP to PSE and the solution proposals for these problems. In this study, a document review was made by reviewing the national and international studies about transition processes of the CHL in Turkey from EEP to PSE. Accordingly, in the study carried out in two stages, firstly, a review of the body of literature was performed by creating key words related to the subject. Secondly, the problems confronted by the CHL in Turkey during the transition period from EEP to PSE and the solution proposals for these problems were demonstrated by analyzing the obtained data. According to the body of literature, it is seen that there are no laws concerning the transition processes of the children who require special care including the CHL in Turkey from EEP (sending) to PSE (receiving), and correspondingly numerous problems have been experienced during the transition period. It seems that the EEP adopts family-centered approaches for strengthening the families of the CHL. However, PSE program aims to prepare the children to school life by focusing on their social and academical development rather with the adoption of children-centered approaches. Therefore, while the families feel an inseparable part of the team in EEP, they indicated that they felt like a stranger in the school team after their children have started to PSE. Therefore, families find the transition processes worrisome and state that they are not satisfied with the process. We discovered that in the process of transition from EEP to PSE, families are not informed, there is a limited number of PSE options available, children cannot adapt to the new educational environment and cannot benefit from the existing PSE.Keywords: early education program, early special education, children with hearing loss, transition
Procedia PDF Downloads 14432456 Dielectric Properties of Thalium Selenide Thin Films at Radio Wave Frequencies
Authors: Onur Potok, Deniz Deger, Kemal Ulutas, Sahin Yakut, Deniz Bozoglu
Abstract:
Thalium Selenide (TlSe) is used for optoelectronic devices, pressure sensitive detectors, and gamma-ray detectors. The TlSe samples were grown as large single crystals using the Stockbarger-Bridgman method. The thin films, in the form of Al/TlSe/Al, were deposited on the microscope slide in different thicknesses (300-3000 Å) using thermal evaporation technique at 10-5 Torr. The dielectric properties of (TlSe) thin films, capacitance (C) and dielectric loss factor (tanδ), were measured in a frequency range of 10-105 Hz, and temperatures between 213K and 393K via Broadband Dielectric Spectroscopy analyzer. The dielectric constant (ε’) and the dielectric loss (ε’’) of the thin films were derived from measured parameters (C and tanδ). These results showed that the dielectric properties of TlSe thin films are frequency and temperature dependent. The capacitance and the dielectric constant decrease with increasing frequency and decreasing temperature. The dielectric loss of TlSe thin films decreases with increasing frequency, on the other hand, they increase with increasing temperature and increasing thicknesses. There is two relaxation region in the investigated frequency and temperature interval. These regions can be called as low and high-frequency dispersion regions. Low-frequency dispersion region can be attributed to the polarization of the main part of the chain structure of TlSe while high-frequency dispersion region can be attributed to the polarization of side parts of the structure.Keywords: thin films, thallium selenide, dielectric spectroscopy, binary compounds
Procedia PDF Downloads 15332455 Mechanic and Thermal Analysis on an 83 kW Electric Motorcycle: A First-Principles Study
Authors: Martín Felipe García Romero, Nancy Mondragón Escamilla, Ismael Araujo Vargas, Viviana Basurto Rios, Kevin Cano Pulido, Pedro Enrique Velázquez Elisondo
Abstract:
This paper presents a preliminary prototype of an 83 kW all-electric motorbike since, nowadays, electric motorbikes have advanced drastically in their technology in such a way that lately, there has been a boom in the field of competition of medium power electric vehicles. The field of electric vehicle racing mainly pursues the aim of obtaining an optimal performance of all the motorbike components in order to obtain a safe racing vehicle fast enough while looking for the stability of all the systems onboard. A general description of the project is given up to date, detailing the parts of the system, integration, numerical estimations, and a rearrangement proposal of the actual prototype with the aim to mechanically and thermally improve the vehicle.Keywords: electric motorcycle, thermal analysis, mechanic analysis, electric vehicle
Procedia PDF Downloads 11732454 Design and Simulation of Variable Air Volume Air Conditioning System Based on Improved Sliding Mode Control
Authors: Abbas Anser, Ahmad Irfan
Abstract:
The main purpose of the VAV (Variable Air Volume) in Heating, Ventilation, and Air Conditioning (HVAC) system is to reduce energy consumption and make the buildings comfortable for the occupants. For better performance of the air conditioning system, different control techniques have been developed. In this paper, an Improved Sliding Mode Control (ISMC), based on Power Rate Exponential Reaching Law (PRERL), has been implemented on a VAV air conditioning system. Through the proposed technique, fast response and robustness have been achieved. To verify the efficacy of ISMC, a comparison of the suggested control technique has been made with Exponential Reaching Law (ERL) based SMC. And secondly, chattering, which is unfavorable as it deteriorates the mechanical parts of the air conditioning system by the continuous movement of the mechanical parts and consequently it increases the energy loss in the air conditioning system, has been alleviated. MATLAB/SIMULINK results show the effectiveness of the utilized scheme, which ensures the enhancement of the energy efficiency of the VAV air conditioning system.Keywords: PID, SMC, HVAC, PRERL, feedback linearization, VAV, chattering
Procedia PDF Downloads 12532453 Sum Capacity with Regularized Channel Inversion in Multi-Antenna Downlink Systems under Equal Power Constraint
Authors: Attaullah Khawaja, Amna Shabbir
Abstract:
Channel inversion is one of the simplest techniques for multiuser downlink systems with single-antenna users. In this paper regularized channel inversion under equal power constraint in the multiuser multiple input multiple output (MU-MIMO) broadcast channels has been considered. Sum capacity with plain channel inversion also known as Zero Forcing Beam Forming (ZFBF) and optimum sum capacity using Dirty Paper Coding (DPC) has also been investigated. Analysis and simulations show that regularization enhances the system performance and empower linear growth in Sum Capacity and specially work well at low signal to noise ratio (SNRs) regime.Keywords: broadcast channel, channel inversion, multiple antenna multiple-user wireless, multiple-input multiple-output (MIMO), regularization, dirty paper coding (DPC), sum capacity
Procedia PDF Downloads 52732452 Position and Speed Tracking of DC Motor Based on Experimental Analysis in LabVIEW
Authors: Muhammad Ilyas, Awais Khan, Syed Ali Raza Shah
Abstract:
DC motors are widely used in industries to provide mechanical power in speed and torque. The position and speed control of DC motors is getting the interest of the scientific community in robotics, especially in the robotic arm, a flexible joint manipulator. The current research work is based on position control of DC motors using experimental investigations in LabVIEW. The linear control strategy is applied to track the position and speed of the DC motor with comparative analysis in the LabVIEW platform and simulation analysis in MATLAB. The tracking error in hardware setup based on LabVIEW programming is slightly greater than simulation analysis in MATLAB due to the inertial load of the motor during steady-state conditions. The controller output shows the input voltage applied to the dc motor varies between 0-8V to ensure minimal steady error while tracking the position and speed of the DC motor.Keywords: DC motor, labview, proportional integral derivative control, position tracking, speed tracking
Procedia PDF Downloads 10632451 Research and Application of the Three-Dimensional Visualization Geological Modeling of Mine
Authors: Bin Wang, Yong Xu, Honggang Qu, Rongmei Liu, Zhenji Gao
Abstract:
Today's mining industry is advancing gradually toward digital and visual direction. The three dimensional visualization geological modeling of mine is the digital characterization of mineral deposit, and is one of the key technology of digital mine. The three-dimensional geological modeling is a technology that combines the geological spatial information management, geological interpretation, geological spatial analysis and prediction, geostatistical analysis, entity content analysis and graphic visualization in three-dimensional environment with computer technology, and is used in geological analysis. In this paper, the three-dimensional geological modeling of an iron mine through the use of Surpac is constructed, and the weight difference of the estimation methods between distance power inverse ratio method and ordinary kriging is studied, and the ore body volume and reserves are simulated and calculated by using these two methods. Compared with the actual mine reserves, its result is relatively accurate, so it provided scientific bases for mine resource assessment, reserve calculation, mining design and so on.Keywords: three-dimensional geological modeling, geological database, geostatistics, block model
Procedia PDF Downloads 7032450 Investigation of Polar Atmospheric Response to the Intense Geo-Space Activities
Authors: Jayanta K. Behera, Ashwini K. Sinha
Abstract:
The study has pointed out the relationship of energetic particle precipitation (EPP) during high speed solar wind streams (HSS) to the ionization characteristics and subsequent NOx production in the polar atmosphere. Over the last few decades, it has been shown that production of NOx in the mesosphere region during the precipitation of charged particles (with energy range >30 KeV to 1 MeV) is directly related to the ozone loss in the polar middle atmosphere, extending from mesosphere to upper stratosphere. This study has dealt with the analysis of the interplanetary parameters such as interplanetary magnetic field (IMF), solar wind velocity (Vs), charged particle density (Ns), convection field enhancement (Ec) during such HSS events and their link to the rate of production of NOx in the mesosphere. Moreover, the analysis will be used to validate or, to modify the current ion-chemistry models which describe the ionization rate and NOx production in the polar atmosphere due to EPP.Keywords: energetic particle precipitation (EPP), NOx, ozone depletion, polar vortex
Procedia PDF Downloads 45932449 Renewable Integration Algorithm to Compensate Photovoltaic Power Using Battery Energy Storage System
Authors: Hyung Joo Lee, Jin Young Choi, Gun Soo Park, Kyo Sun Oh, Dong Jun Won
Abstract:
The fluctuation of the output of the renewable generator caused by weather conditions must be mitigated because it imposes strain on the system and adversely affects power quality. In this paper, we focus on mitigating the output fluctuation of the photovoltaic (PV) using battery energy storage system (BESS). To satisfy tight conditions of system, proposed algorithm is developed. This algorithm focuses on adjusting the integrated output curve considering state of capacity (SOC) of the battery. In this paper, the simulation model is PSCAD / EMTDC software. SOC of the battery and the overall output curve are shown using the simulation results. We also considered losses and battery efficiency.Keywords: photovoltaic generation, battery energy storage system, renewable integration, power smoothing
Procedia PDF Downloads 28132448 The Different Essence of Death in the Elegies of Shelley's Adonais and Lord Tennyson's In Memoriam
Authors: Sulistyaningtyas
Abstract:
The topic about death and dying is interesting to discuss since it is strongly related to every individual life. As represented in its title, Adonais: An Elegy on the Death of John Keats is a mournful poem written in 1821 by Percy Bysshe Shelley to mourn the loss of young poet John Keats. To compare, In Memoriam A.H.H. is an elegy written in 1850 about the death of Lord Tennyson’s dearest friend, Arthur Henry Hallam. Although both elegies were written to grieve the authors’ loved ones, their grief affects differently to the psychological being of the narrators. Thus, this research aims to examine the essence of death in affecting the narrators psychologically. By using psychoanalytic criticism, this research reveals the different essence of death in the two elegies as the result of the analysis. Moreover, these two elegies also portray the concept of the afterlife, immortality, and the figure of God. In Adonais, the grief of the narrator to Keats leads him to question the very purpose of life. The loss of his favorite poet which makes him feel sorrowful and mad along his 55 stanzas brings him to a higher psychological level to understand himself. He even sees himself as a Christ-like figure, which shows the idea that God is imaginable. Different from Adonais, the narrator of In Memoriam finds something more spiritual by doing his passionate mourning to Hallam. Through some contemplation in his 133 cantos, in the end, he is convinced that the dear one now dwells with a great Spirit who controls the world. He believes that all of the creation in the universe has to follow one law which is set by God. Hence, it can be concluded that death might bring different consequence to the psyche of every living creature.Keywords: elegy, comparative study, psychoanalytic criticism, the essence of death
Procedia PDF Downloads 42332447 Optical Properties of TlInSe₂<AU> Si̇ngle Crystals
Authors: Gulshan Mammadova
Abstract:
This paper presents the results of studying the surface microrelief in 2D and 3D models and analyzing the spectroscopy of a three-junction TlInSe₂Keywords: optical properties, dielectric permittivity, real and imaginary dielectric permittivity, optical electrical conductivity
Procedia PDF Downloads 6332446 Power Iteration Clustering Based on Deflation Technique on Large Scale Graphs
Authors: Taysir Soliman
Abstract:
One of the current popular clustering techniques is Spectral Clustering (SC) because of its advantages over conventional approaches such as hierarchical clustering, k-means, etc. and other techniques as well. However, one of the disadvantages of SC is the time consuming process because it requires computing the eigenvectors. In the past to overcome this disadvantage, a number of attempts have been proposed such as the Power Iteration Clustering (PIC) technique, which is one of versions from SC; some of PIC advantages are: 1) its scalability and efficiency, 2) finding one pseudo-eigenvectors instead of computing eigenvectors, and 3) linear combination of the eigenvectors in linear time. However, its worst disadvantage is an inter-class collision problem because it used only one pseudo-eigenvectors which is not enough. Previous researchers developed Deflation-based Power Iteration Clustering (DPIC) to overcome problems of PIC technique on inter-class collision with the same efficiency of PIC. In this paper, we developed Parallel DPIC (PDPIC) to improve the time and memory complexity which is run on apache spark framework using sparse matrix. To test the performance of PDPIC, we compared it to SC, ESCG, ESCALG algorithms on four small graph benchmark datasets and nine large graph benchmark datasets, where PDPIC proved higher accuracy and better time consuming than other compared algorithms.Keywords: spectral clustering, power iteration clustering, deflation-based power iteration clustering, Apache spark, large graph
Procedia PDF Downloads 18932445 Hidden Markov Model for Financial Limit Order Book and Its Application to Algorithmic Trading Strategy
Authors: Sriram Kashyap Prasad, Ionut Florescu
Abstract:
This study models the intraday asset prices as driven by Markov process. This work identifies the latent states of the Hidden Markov model, using limit order book data (trades and quotes) to continuously estimate the states throughout the day. This work builds a trading strategy using estimated states to generate signals. The strategy utilizes current state to recalibrate buy/ sell levels and the transition between states to trigger stop-loss when adverse price movements occur. The proposed trading strategy is tested on the Stevens High Frequency Trading (SHIFT) platform. SHIFT is a highly realistic market simulator with functionalities for creating an artificial market simulation by deploying agents, trading strategies, distributing initial wealth, etc. In the implementation several assets on the NASDAQ exchange are used for testing. In comparison to a strategy with static buy/ sell levels, this study shows that the number of limit orders that get matched and executed can be increased. Executing limit orders earns rebates on NASDAQ. The system can capture jumps in the limit order book prices, provide dynamic buy/sell levels and trigger stop loss signals to improve the PnL (Profit and Loss) performance of the strategy.Keywords: algorithmic trading, Hidden Markov model, high frequency trading, limit order book learning
Procedia PDF Downloads 15132444 Perovskite Solar Cells Penetration on Electric Grids Based on the Power Hardware in the Loop Methodology
Authors: Alaa A. Zaky, Bandar Alfaifi, Saleh Alyahya, Alkistis Kontou, Panos Kotsampopoulos
Abstract:
In this work, we present for the first time the grid-integration of 3rd generation perovskite solar cells (PSCs) based on nanotechnology in fabrication. The effect of this penetration is analyzed in normal, fault and islanding cases of operation under different irradiation conditions using the power hardware in the loop (PHIL) methodology. The PHL method allows the PSCs connection to the electric grid which is simulated in the real-time digital simulator (RTDS), for laboratory validation of the PSCs behavior under conditions very close to real.Keywords: perovskite solar cells, power hardware in the loop, real-time digital simulator, smart grid
Procedia PDF Downloads 2632443 Dimensional Accuracy of CNTs/PMMA Parts and Holes Produced by Laser Cutting
Authors: A. Karimzad Ghavidel, M. Zadshakouyan
Abstract:
Laser cutting is a very common production method for cutting 2D polymeric parts. Developing of polymer composites with nano-fibers makes important their other properties like laser workability. The aim of this research is investigation of the influence different laser cutting conditions on the dimensional accuracy of parts and holes from poly methyl methacrylate (PMMA)/carbon nanotubes (CNTs) material. Experiments were carried out by considering of CNTs (in four level 0,0.5, 1 and 1.5% wt.%), laser power (60, 80, and 100 watt) and cutting speed 20, 30, and 40 mm/s as input variable factors. The results reveal that CNTs adding improves the laser workability of PMMA and the increasing of power has a significant effect on the part and hole size. The findings also show cutting speed is effective parameter on the size accuracy. Eventually, the statistical analysis of results was done, and calculated mathematical equations by the regression are presented for determining relation between input and output factor.Keywords: dimensional accuracy, PMMA, CNTs, laser cutting
Procedia PDF Downloads 30632442 The M Health Paradigm for the Chronic Care Management of Obesity: New Opportunities in Clinical Psychology and Medicine
Authors: Gianluca Castelnuovo, Gian Mauro Manzoni, Giada Pietrabissa, Stefania Corti, Emanuele Giusti, Roberto Cattivelli, Enrico Molinari, Susan Simpson
Abstract:
Obesity is currently an important public health problem of epidemic proportions (globesity). Moreover Binge Eating Disorder (BED) is typically connected with obesity, even if not occurring exclusively in conjunction with overweight conditions. Typically obesity with BED requires a longer term treatment in comparison with simple obesity. Rehabilitation interventions that aim at improving weight-loss, reducing obesity-related complications and changing dysfunctional behaviors, should ideally be carried out in a multidisciplinary context with a clinical team composed of psychologists, dieticians, psychiatrists, endocrinologists, nutritionists, physiotherapists, etc. Long-term outpatient multidisciplinary treatments are likely to constitute an essential aspect of rehabilitation, due to the growing costs of a limited inpatient approach. Internet-based technologies can improve long-term obesity rehabilitation within a collaborative approach. The new m health (m-health, mobile health) paradigm, defined as clinical practices supported by up to date mobile communication devices, could increase compliance- engagement and contribute to a significant cost reduction in BED and obesity rehabilitation. Five psychological components need to be considered for successful m Health-based obesity rehabilitation in order to facilitate weight-loss.1) Self-monitoring. Portable body monitors, pedometers and smartphones are mobile and, therefore, can be easily used, resulting in continuous self-monitoring. 2) Counselor feedback and communication. A functional approach is to provide online weight-loss interventions with brief weekly or monthly counselor or psychologist visits. 3) Social support. A group treatment format is typically preferred for behavioral weight-loss interventions. 4) Structured program. Technology-based weight-loss programs incorporate principles of behavior therapy and change with structured weekly protocolos including nutrition, exercise, stimulus control, self-regulation strategies, goal-setting. 5) Individually tailored program. Interventions specifically designed around individual’s goals typically record higher rates of adherence and weight loss. Opportunities and limitations of m health approach in clinical psychology for obesity and BED are discussed, taking into account future research directions in this promising area.Keywords: obesity, rehabilitation, out-patient, new technologies, tele medicine, tele care, m health, clinical psychology, psychotherapy, chronic care management
Procedia PDF Downloads 47332441 Photocapacitor Integrating Solar Energy Conversion and Energy Storage
Authors: Jihuai Wu, Zeyu Song, Zhang Lan, Liuxue Sun
Abstract:
Solar energy is clean, open, and infinite, but solar radiation on the earth is fluctuating, intermittent, and unstable. So, the sustainable utilization of solar energy requires a combination of high-efficient energy conversion and low-loss energy storage technologies. Hence, a photo capacitor integrated with photo-electrical conversion and electric-chemical storage functions in single device is a cost-effective, volume-effective and functional-effective optimal choice. However, owing to the multiple components, multi-dimensional structure and multiple functions in one device, especially the mismatch of the functional modules, the overall conversion and storage efficiency of the photocapacitors is less than 13%, which seriously limits the development of the integrated system of solar conversion and energy storage. To this end, two typical photocapacitors were studied. A three-terminal photocapacitor was integrated by using perovskite solar cell as solar conversion module and symmetrical supercapacitor as energy storage module. A function portfolio management concept was proposed the relationship among various efficiencies during photovoltaic conversion and energy storage process were clarified. By harmonizing the energy matching between conversion and storage modules and seeking the maximum power points coincide and the maximum efficiency points synchronize, the overall efficiency of the photocapacitor surpassed 18 %, and Joule efficiency was closed to 90%. A voltage adjustable hybrid supercapacitor (VAHSC) was designed as energy storage module, and two Si wafers in series as solar conversion module, a three-terminal photocapacitor was fabricated. The VAHSC effectively harmonizes the energy harvest and storage modules, resulting in the current, voltage, power, and energy match between both modules. The optimal photocapacitor achieved an overall efficiency of 15.49% and Joule efficiency of 86.01%, along with excellent charge/discharge cycle stability. In addition, the Joule efficiency (ηJoule) was defined as the energy ratio of discharge/charge of the devices for the first time.Keywords: joule efficiency, perovskite solar cell, photocapacitor, silicon solar cell, supercapacitor
Procedia PDF Downloads 8632440 Agroforestry Systems: A Sustainable Strategy of the Agricultural Systems of Cumaral (Meta), Colombia
Authors: Amanda Silva Parra, Dayra Yisel García Ramirez
Abstract:
In developing countries, agricultural "modernization" has led to a loss of biodiversity and inefficiency of agricultural systems, manifested in increases in Greenhouse Gas Emissions (GHG) and the C footprint, generating the susceptibility of systems agriculture to environmental problems, loss of biodiversity, depletion of natural resources, soil degradation and loss of nutrients, and a decrease in the supply of products that affect food security for peoples and nations. Each year agriculture emits 10 to 12% (5.1 to 6.1 Gt CO2eq per year) of the total estimated GHG emissions (51 Gt CO2 eq per year). The FAO recommends that countries that have not yet done so consider declaring sustainable agriculture as an essential or strategic activity of public interest within the framework of green economies to better face global climate change. The objective of this research was to estimate the balance of GHG in agricultural systems of Cumaral, Meta (Colombia), to contribute to the recovery and sustainable operation of agricultural systems that guarantee food security and face changes generated by the climate in a more intelligent way. To determine the GHG balances, the IPCC methodologies were applied with a Tier 1 and 2 level of use. It was estimated that all the silvopastoral systems evaluated play an important role in this reconversion compared to conventional systems such as improved pastures. and degraded pastures due to their ability to capture C both in soil and in biomass, generating positive GHG balances, guaranteeing greater sustainability of soil and air resources.Keywords: climate change, carbon capture, environmental sustainability, GHG mitigation, silvopastoral systems
Procedia PDF Downloads 11832439 Determinants of Hospital Obstetric Unit Closures in the United States 2002-2013: Loss of Hospital Obstetric Care 2002-2013
Authors: Peiyin Hung, Katy Kozhimannil, Michelle Casey, Ira Moscovice
Abstract:
Background/Objective: The loss of obstetric services has been a pressing concern in urban and rural areas nationwide. This study aims to determine factors that contribute to the loss of obstetric care through closures of a hospital or obstetric unit. Methods: Data from 2002-2013 American Hospital Association annual surveys were used to identify hospitals providing obstetric services. We linked these data to Medicare Healthcare Cost Report Information for hospital financial indicators, the US Census Bureau’s American Community Survey for zip-code level characteristics, and Area Health Resource files for county- level clinician supply measures. A discrete-time multinomial logit model was used to determine contributing factors to obstetric unit or hospital closures. Results: Of 3,551 hospitals providing obstetrics services during 2002-2013, 82% kept units open, 12% stopped providing obstetrics services, and 6% closed down completely. State-level variations existed. Factors that significantly increased hospitals’ probability of obstetric unit closures included lower than 250 annual birth volume (adjusted marginal effects [95% confidence interval]=34.1% [28%, 40%]), closer proximity to another hospital with obstetric services (per 10 miles: -1.5% [-2.4, -0.5%]), being in a county with lower family physician supply (-7.8% [-15.0%, -0.6%), being in a zip code with higher percentage of non-white females (per 10%: 10.2% [2.1%, 18.3%]), and with lower income (per $1,000 income: -0.14% [-0.28%, -0.01%]). Conclusions: Over the past 12 years, loss of obstetric services has disproportionately affected areas served by low-volume urban and rural hospitals, non-white and low-income communities, and counties with fewer family physicians, signaling a need to address maternity care access in these communities.Keywords: access to care, obstetric care, service line discontinuation, hospital, obstetric unit closures
Procedia PDF Downloads 22232438 A Simple and Efficient Method for Accurate Measurement and Control of Power Frequency Deviation
Authors: S. J. Arif
Abstract:
In the presented technique, a simple method is given for accurate measurement and control of power frequency deviation. The sinusoidal signal for which the frequency deviation measurement is required is transformed to a low voltage level and passed through a zero crossing detector to convert it into a pulse train. Another stable square wave signal of 10 KHz is obtained using a crystal oscillator and decade dividing assemblies (DDA). These signals are combined digitally and then passed through decade counters to give a unique combination of pulses or levels, which are further encoded to make them equally suitable for both control applications and display units. The developed circuit using discrete components has a resolution of 0.5 Hz and completes measurement within 20 ms. The realized circuit is simulated and synthesized using Verilog HDL and subsequently implemented on FPGA. The results of measurement on FPGA are observed on a very high resolution logic analyzer. These results accurately match the simulation results as well as the results of same circuit implemented with discrete components. The proposed system is suitable for accurate measurement and control of power frequency deviation.Keywords: digital encoder for frequency measurement, frequency deviation measurement, measurement and control systems, power systems
Procedia PDF Downloads 37632437 Transmission of ASCII Code Messages Using a High Power (50mW) Underwater Laser Communication Prototype in Two Controlled Scenarios
Authors: Lessly Borja, Anthony Gualli, Kelly Baño, Fabricio Santacruz
Abstract:
In this article, a prototype of underwater communication using a long-range laser (50mW) has been carried out in two aquatic scenarios (fish tank and swimming pool) with the aim of recreating Aqua-Fi technology (the future of underwater communications) using a Bluetooth connection to the transmitter to send data in ASCII code by means of light. Initially, the transmitter and receiver circuits were programmed in Arduino so that the data would travel by light pulses in the aforementioned code. To obtain the results of the underwater communication, two scenarios were chosen (fish tank and swimming pool), where the power value of the received signal was calculated from its peak-to-peak voltage using the Oscilloscope equipment (ESPOCH). Finally, it was concluded that the maximum communication range of this prototype is 12m underwater, and it was observed that the power decreases as the distance increases. However, this prototype still needs to improve communication so that the information is not distorted or lost when there is movement and dispersion of the water. It is hoped that it will form the basis for future research.Keywords: prototype, underwater, communication, power, voltage, distance
Procedia PDF Downloads 91