Search results for: standard error
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 6541

Search results for: standard error

6121 Artificial Neural Networks Based Calibration Approach for Six-Port Receiver

Authors: Nadia Chagtmi, Nejla Rejab, Noureddine Boulejfen

Abstract:

This paper presents a calibration approach based on artificial neural networks (ANN) to determine the envelop signal (I+jQ) of a six-port based receiver (SPR). The memory effects called also dynamic behavior and the nonlinearity brought by diode based power detector have been taken into consideration by the ANN. Experimental set-up has been performed to validate the efficiency of this method. The efficiency of this approach has been confirmed by the obtained results in terms of waveforms. Moreover, the obtained error vector magnitude (EVM) and the mean absolute error (MAE) have been calculated in order to confirm and to test the ANN’s performance to achieve I/Q recovery using the output voltage detected by the power based detector. The baseband signal has been recovered using ANN with EVMs no higher than 1 % and an MAE no higher than 17, 26 for the SPR excited different type of signals such QAM (quadrature amplitude modulation) and LTE (Long Term Evolution).

Keywords: six-port based receiver; calibration, nonlinearity, memory effect, artificial neural network

Procedia PDF Downloads 52
6120 Effects of Dimensional Sizes of Mould on the Volumetric Shrinkage Strain of Lateric Soil

Authors: John E. Sani, Moses George

Abstract:

The paper presents the result of a laboratory study carried out on lateritic soil to determine the effects of dimensional size on the volumetric shrinkage strain (VSS) using three mould sizes i.e. split former mould, proctor mould and California bearing ratio (CBR) mould at three energy levels; British standard light (BSL), West African standard (WAS) and British standard heavy (BSH) respectively. Compactions were done at different molding water content of -2 % to +6 % optimum moisture content (OMC). At -2% to +2% molding water content for the split former mould the volumetric shrinkage strain met the requirement of not more than 4% while at +4% and +6% only the WAS and BSH met the requirement. The proctor mould and the CBR mould on the other hand gave a lower value of volumetric shrinkage strain in all compactive effort and the values are lower than the 4% safe VSS value.

Keywords: lateritic soil, volumetric shrinkage strain, molding water content, compactive effort

Procedia PDF Downloads 509
6119 Handling Missing Data by Using Expectation-Maximization and Expectation-Maximization with Bootstrapping for Linear Functional Relationship Model

Authors: Adilah Abdul Ghapor, Yong Zulina Zubairi, A. H. M. R. Imon

Abstract:

Missing value problem is common in statistics and has been of interest for years. This article considers two modern techniques in handling missing data for linear functional relationship model (LFRM) namely the Expectation-Maximization (EM) algorithm and Expectation-Maximization with Bootstrapping (EMB) algorithm using three performance indicators; namely the mean absolute error (MAE), root mean square error (RMSE) and estimated biased (EB). In this study, we applied the methods of imputing missing values in two types of LFRM namely the full model of LFRM and in LFRM when the slope is estimated using a nonparametric method. Results of the simulation study suggest that EMB algorithm performs much better than EM algorithm in both models. We also illustrate the applicability of the approach in a real data set.

Keywords: expectation-maximization, expectation-maximization with bootstrapping, linear functional relationship model, performance indicators

Procedia PDF Downloads 439
6118 Trends in Domestic Terms of Trade of Agricultural Sector of Pakistan

Authors: Anwar Hussain, Muhammad Iqbal

Abstract:

The changes in the prices of the agriculture commodities combined with changes in population and agriculture productivity affect farmers’ profitability and standard of living. This study intends to estimate various domestic terms of trade for agriculture sector and also to assess the volatility in the standard of living and profitability of farmers. The terms of trade has been estimated for Pakistan and its provinces using producer prices indices, consumer price indices, input prices indices and quantity indices using the data for the period 1990-91 to 2008-09. The domestic terms of trade of agriculture sector has been improved in terms of both approaches i.e. the ratio of producer prices indices to consumer prices indices and the real per capita income approach. However, the cross province estimates indicated that the terms of trade also improved for Khyber Pakhtunkhwa, Sindh and Punjab while Balochistan’s domestic terms of trade deteriorated drastically. In other words the standard of living of the farmers in Pakistan and its provinces except Balochistan improved. Using the input prices, the domestic terms of trade deteriorated for Pakistan as a whole and its provinces as well. This also explores that as a whole the profitability of the farmers reduced during the study period. The farmers pay more prices for inputs as compared to they receive for their produce. This further indicates that the poverty at the gross root level has been increased. Further, summing, the standard of living of the farmers improved but their profitability reduced, which indicates that the farmers do not completely rely on the farm income but also utilize some other sources of income for their livelihood. The study supports to give subsidies on farm inputs so as to improve the profitability of the farmers.

Keywords: agricultural terms of trade, farmers’ profitability, farmers’ standard of living, consumer and producer price indices, quantity indices

Procedia PDF Downloads 446
6117 On-Site Coaching on Freshly-Graduated Nurses to Improves Quality of Clinical Handover and to Avoid Clinical Error

Authors: Sau Kam Adeline Chan

Abstract:

World Health Organization had listed ‘Communication during Patient Care Handovers’ as one of its highest 5 patient safety initiatives. Clinical handover means transfer of accountability and responsibility of clinical information from one health professional to another. The main goal of clinical handover is to convey patient’s current condition and treatment plan accurately. Ineffective communication at point of care is globally regarded as the main cause of the sentinel event. Situation, Background, Assessment and Recommendation (SBAR), a communication tool, is extensively regarded as an effective communication tool in healthcare setting. Nonetheless, just by scenario-based program in nursing school or attending workshops on SBAR would not be enough for freshly graduated nurses to apply it competently in a complex clinical practice. To what extend and in-depth of information should be conveyed during handover process is not easy to learn. As such, on-site coaching is essential to upgrade their expertise on the usage of SBAR and ultimately to avoid any clinical error. On-site coaching for all freshly graduated nurses on the usage of SBAR in clinical handover was commenced in August 2014. During the preceptorship period, freshly graduated nurses were coached by the preceptor. After that, they were gradually assigned to take care of a group of patients independently. Nurse leaders would join in their shift handover process at patient’s bedside. Feedback and support were given to them accordingly. Discrepancies on their clinical handover process were shared with them and documented for further improvement work. Owing to the constraint of manpower in nurse leader, about coaching for 30 times were provided to a nurse in a year. Staff satisfaction survey was conducted to gauge their feelings about the coaching and look into areas for further improvement. Number of clinical error avoided was documented as well. The nurses reported that there was a significant improvement particularly in their confidence and knowledge in clinical handover process. In addition, the sense of empowerment was developed when liaising with senior and experienced nurses. Their proficiency in applying SBAR was enhanced and they become more alert to the critical criteria of an effective clinical handover. Most importantly, accuracy of transferring patient’s condition was improved and repetition of information was avoided. Clinical errors were prevented and quality patient care was ensured. Using SBAR as a communication tool looks simple. The tool only provides a framework to guide the handover process. Nevertheless, without on-site training, loophole on clinical handover still exists, patient’s safety will be affected and clinical error still happens.

Keywords: freshly graduated nurse, competency of clinical handover, quality, clinical error

Procedia PDF Downloads 131
6116 H.263 Based Video Transceiver for Wireless Camera System

Authors: Won-Ho Kim

Abstract:

In this paper, a design of H.263 based wireless video transceiver is presented for wireless camera system. It uses standard WIFI transceiver and the covering area is up to 100m. Furthermore the standard H.263 video encoding technique is used for video compression since wireless video transmitter is unable to transmit high capacity raw data in real time and the implemented system is capable of streaming at speed of less than 1Mbps using NTSC 720x480 video.

Keywords: wireless video transceiver, video surveillance camera, H.263 video encoding digital signal processing

Procedia PDF Downloads 351
6115 A Greedy Alignment Algorithm Supporting Medication Reconciliation

Authors: David Tresner-Kirsch

Abstract:

Reconciling patient medication lists from multiple sources is a critical task supporting the safe delivery of patient care. Manual reconciliation is a time-consuming and error-prone process, and recently attempts have been made to develop efficiency- and safety-oriented automated support for professionals performing the task. An important capability of any such support system is automated alignment – finding which medications from a list correspond to which medications from a different source, regardless of misspellings, naming differences (e.g. brand name vs. generic), or changes in treatment (e.g. switching a patient from one antidepressant class to another). This work describes a new algorithmic solution to this alignment task, using a greedy matching approach based on string similarity, edit distances, concept extraction and normalization, and synonym search derived from the RxNorm nomenclature. The accuracy of this algorithm was evaluated against a gold-standard corpus of 681 medication records; this evaluation found that the algorithm predicted alignments with 99% precision and 91% recall. This performance is sufficient to support decision support applications for medication reconciliation.

Keywords: clinical decision support, medication reconciliation, natural language processing, RxNorm

Procedia PDF Downloads 267
6114 Evaluation of the Effectiveness of the Argon Plasma Jet on Healing Process of the Wagner Grade 2 Diabetic Foot Ulcer

Authors: M. Khaledi Pour, P. Akbartehrani, M. Amini, M. Khani, M. Mohajeri Tehrani, R. Radi, B. Shokri

Abstract:

Diabetic Foot Ulcer (DFU) is one of the costly severe complications of diabetes. Neuropathy and Peripheral Arterial Disease (PAD) due to diabetes are significant causes of this complication. In 10 years the patients with DFUs are twice as likely to die as patients without DFUs. Cold Atmospheric Plasma (CAP) is a promising tool for medical purposes. CAP generate reactive species at room temperature and are effective in killing bacteria and fibroblast proliferation. These CAP-based tools produce NO, which has bactericidal and angiogenesis properties. It also showed promising effects in the DFUs surface reduction and the time to wound closure. In this paper, we evaluated the effect of the Argon Plasma Jet (APJ) on the healing process of the Wagner Grade 2 DFUs in a randomized clinical trial. The 20 kHz sinusoidal voltage frequency derives the APJ. Patients (n=20) were randomly double-blinded assigned into two groups. These groups receive the standard care (SC, n=10) and the standard care with APJ treatment (SC+APJ, n=10) for five sessions in four weeks. The results showed that the APJ treatment along standard care could reduce the wound surface by 20 percent more than the standard care. Also, It showed a more influential role in controlling wound infection.

Keywords: argon plasma jet, cold atmospheric plasma, diabetes, diabetic foot ulcer

Procedia PDF Downloads 180
6113 Comparison of Statistical Methods for Estimating Missing Precipitation Data in the River Subbasin Lenguazaque, Colombia

Authors: Miguel Cañon, Darwin Mena, Ivan Cabeza

Abstract:

In this work was compared and evaluated the applicability of statistical methods for the estimation of missing precipitations data in the basin of the river Lenguazaque located in the departments of Cundinamarca and Boyacá, Colombia. The methods used were the method of simple linear regression, distance rate, local averages, mean rates, correlation with nearly stations and multiple regression method. The analysis used to determine the effectiveness of the methods is performed by using three statistical tools, the correlation coefficient (r2), standard error of estimation and the test of agreement of Bland and Altmant. The analysis was performed using real rainfall values removed randomly in each of the seasons and then estimated using the methodologies mentioned to complete the missing data values. So it was determined that the methods with the highest performance and accuracy in the estimation of data according to conditions that were counted are the method of multiple regressions with three nearby stations and a random application scheme supported in the precipitation behavior of related data sets.

Keywords: statistical comparison, precipitation data, river subbasin, Bland and Altmant

Procedia PDF Downloads 454
6112 Evaluation of Three Digital Graphical Methods of Baseflow Separation Techniques in the Tekeze Water Basin in Ethiopia

Authors: Alebachew Halefom, Navsal Kumar, Arunava Poddar

Abstract:

The purpose of this work is to specify the parameter values, the base flow index (BFI), and to rank the methods that should be used for base flow separation. Three different digital graphical approaches are chosen and used in this study for the purpose of comparison. The daily time series discharge data were collected from the site for a period of 30 years (1986 up to 2015) and were used to evaluate the algorithms. In order to separate the base flow and the surface runoff, daily recorded streamflow (m³/s) data were used to calibrate procedures and get parameter values for the basin. Additionally, the performance of the model was assessed by the use of the standard error (SE), the coefficient of determination (R²), and the flow duration curve (FDC) and baseflow indexes. The findings indicate that, in general, each strategy can be used worldwide to differentiate base flow; however, the Sliding Interval Method (SIM) performs significantly better than the other two techniques in this basin. The average base flow index was calculated to be 0.72 using the local minimum method, 0.76 using the fixed interval method, and 0.78 using the sliding interval method, respectively.

Keywords: baseflow index, digital graphical methods, streamflow, Emba Madre Watershed

Procedia PDF Downloads 58
6111 The Classification Performance in Parametric and Nonparametric Discriminant Analysis for a Class- Unbalanced Data of Diabetes Risk Groups

Authors: Lily Ingsrisawang, Tasanee Nacharoen

Abstract:

Introduction: The problems of unbalanced data sets generally appear in real world applications. Due to unequal class distribution, many research papers found that the performance of existing classifier tends to be biased towards the majority class. The k -nearest neighbors’ nonparametric discriminant analysis is one method that was proposed for classifying unbalanced classes with good performance. Hence, the methods of discriminant analysis are of interest to us in investigating misclassification error rates for class-imbalanced data of three diabetes risk groups. Objective: The purpose of this study was to compare the classification performance between parametric discriminant analysis and nonparametric discriminant analysis in a three-class classification application of class-imbalanced data of diabetes risk groups. Methods: Data from a healthy project for 599 staffs in a government hospital in Bangkok were obtained for the classification problem. The staffs were diagnosed into one of three diabetes risk groups: non-risk (90%), risk (5%), and diabetic (5%). The original data along with the variables; diabetes risk group, age, gender, cholesterol, and BMI was analyzed and bootstrapped up to 50 and 100 samples, 599 observations per sample, for additional estimation of misclassification error rate. Each data set was explored for the departure of multivariate normality and the equality of covariance matrices of the three risk groups. Both the original data and the bootstrap samples show non-normality and unequal covariance matrices. The parametric linear discriminant function, quadratic discriminant function, and the nonparametric k-nearest neighbors’ discriminant function were performed over 50 and 100 bootstrap samples and applied to the original data. In finding the optimal classification rule, the choices of prior probabilities were set up for both equal proportions (0.33: 0.33: 0.33) and unequal proportions with three choices of (0.90:0.05:0.05), (0.80: 0.10: 0.10) or (0.70, 0.15, 0.15). Results: The results from 50 and 100 bootstrap samples indicated that the k-nearest neighbors approach when k = 3 or k = 4 and the prior probabilities of {non-risk:risk:diabetic} as {0.90:0.05:0.05} or {0.80:0.10:0.10} gave the smallest error rate of misclassification. Conclusion: The k-nearest neighbors approach would be suggested for classifying a three-class-imbalanced data of diabetes risk groups.

Keywords: error rate, bootstrap, diabetes risk groups, k-nearest neighbors

Procedia PDF Downloads 419
6110 Optimal Design of Reference Node Placement for Wireless Indoor Positioning Systems in Multi-Floor Building

Authors: Kittipob Kondee, Chutima Prommak

Abstract:

In this paper, we propose an optimization technique that can be used to optimize the placements of reference nodes and improve the location determination performance for the multi-floor building. The proposed technique is based on Simulated Annealing algorithm (SA) and is called MSMR-M. The performance study in this work is based on simulation. We compare other node-placement techniques found in the literature with the optimal node-placement solutions obtained from our optimization. The results show that using the optimal node-placement obtained by our proposed technique can improve the positioning error distances up to 20% better than those of the other techniques. The proposed technique can provide an average error distance within 1.42 meters.

Keywords: indoor positioning system, optimization system design, multi-floor building, wireless sensor networks

Procedia PDF Downloads 225
6109 Thermoluminescence Characteristic of Nanocrystalline BaSO4 Doped with Europium

Authors: Kanika S. Raheja, A. Pandey, Shaila Bahl, Pratik Kumar, S. P. Lochab

Abstract:

The subject of undertaking for this paper is the study of BaSO4 nanophosphor doped with Europium in which mainly the concentration of the rare earth impurity Eu (0.05, 0.1, 0.2, 0.5, and 1 mol %) has been varied. A comparative study of the thermoluminescence(TL) properties of the given nanophosphor has also been done using a well-known standard dosimetry material i.e. TLD-100.Firstly, a number of samples were prepared successfully by the chemical co-precipitation method. The whole lot was then compared to a well established standard material (TLD-100) for its TL sensitivity property. BaSO4:Eu ( 0.2 mol%) showed the highest sensitivity out of the lot. It was also found that when compared to the standard TLD-100, BaSo4:Eu (0.2mol%) showed surprisingly high sensitivity for a large range of doses. The TL response curve for all prepared samples has also been studied over a wide range of doses i.e 10Gy to 2kGy for gamma radiation. Almost all the samples of BaSO4:Eu showed a remarkable linearity for a broad range of doses, which is a characteristic feature of a fine TL dosimeter. The graph remained linear even beyond 1kGy for gamma radiation. Thus, the given nanophosphor has been successfully optimised for the concentration of the dopant material to achieve its highest TL sensitivity. Further, the comparative study with the standard material revealed that the current optimised sample shows an astonishingly better TL sensitivity and a phenomenal linear response curve for an incredibly wide range of doses for gamma radiation (Co-60) as compared to the standard TLD-100, which makes the current optimised BaSo4:Eu quite promising as an efficient gamma radiation dosimeter. Lastly, the present phosphor has been optimised for its annealing temperature to acquire the best results while also studying its fading and reusability properties.

Keywords: gamma radiation, nanoparticles, radiation dosimetry, thermoluminescence

Procedia PDF Downloads 416
6108 Using Squeezed Vacuum States to Enhance the Sensitivity of Ground Based Gravitational Wave Interferometers beyond the Standard Quantum Limit

Authors: Giacomo Ciani

Abstract:

This paper reviews the impact of quantum noise on modern gravitational wave interferometers and explains how squeezed vacuum states are used to push the noise below the standard quantum limit. With the first detection of gravitational waves from a pair of colliding black holes in September 2015 and subsequent detections including that of gravitational waves from a pair of colliding neutron stars, the ground-based interferometric gravitational wave observatories LIGO and VIRGO have opened the era of gravitational-wave and multi-messenger astronomy. Improving the sensitivity of the detectors is of paramount importance to increase the number and quality of the detections, fully exploiting this new information channel about the universe. Although still in the commissioning phase and not at nominal sensitivity, these interferometers are designed to be ultimately limited by a combination of shot noise and quantum radiation pressure noise, which define an envelope known as the standard quantum limit. Despite the name, this limit can be beaten with the use of advanced quantum measurement techniques, with the use of squeezed vacuum states being currently the most mature and promising. Different strategies for implementation of the technology in the large-scale detectors, in both their frequency-independent and frequency-dependent variations, are presented, together with an analysis of the main technological issues and expected sensitivity gain.

Keywords: gravitational waves, interferometers, squeezed vacuum, standard quantum limit

Procedia PDF Downloads 137
6107 Design and Simulation of Unified Power Quality Conditioner based on Adaptive Fuzzy PI Controller

Authors: Brahim Ferdi, Samira Dib

Abstract:

The unified power quality conditioner (UPQC), a combination of shunt and series active power filter, is one of the best solutions towards the mitigation of voltage and current harmonics problems in distribution power system. PI controller is very common in the control of UPQC. However, one disadvantage of this conventional controller is the difficulty in tuning its gains (Kp and Ki). To overcome this problem, an adaptive fuzzy logic PI controller is proposed. The controller is composed of fuzzy controller and PI controller. According to the error and error rate of the control system and fuzzy control rules, the fuzzy controller can online adjust the two gains of the PI controller to get better performance of UPQC. Simulations using MATLAB/SIMULINK are carried out to verify the performance of the proposed controller. The results show that the proposed controller has fast dynamic response and high accuracy of tracking the current and voltage references.

Keywords: adaptive fuzzy PI controller, current harmonics, PI controller, voltage harmonics, UPQC

Procedia PDF Downloads 533
6106 Graph Cuts Segmentation Approach Using a Patch-Based Similarity Measure Applied for Interactive CT Lung Image Segmentation

Authors: Aicha Majda, Abdelhamid El Hassani

Abstract:

Lung CT image segmentation is a prerequisite in lung CT image analysis. Most of the conventional methods need a post-processing to deal with the abnormal lung CT scans such as lung nodules or other lesions. The simplest similarity measure in the standard Graph Cuts Algorithm consists of directly comparing the pixel values of the two neighboring regions, which is not accurate because this kind of metrics is extremely sensitive to minor transformations such as noise or other artifacts problems. In this work, we propose an improved version of the standard graph cuts algorithm based on the Patch-Based similarity metric. The boundary penalty term in the graph cut algorithm is defined Based on Patch-Based similarity measurement instead of the simple intensity measurement in the standard method. The weights between each pixel and its neighboring pixels are Based on the obtained new term. The graph is then created using theses weights between its nodes. Finally, the segmentation is completed with the minimum cut/Max-Flow algorithm. Experimental results show that the proposed method is very accurate and efficient, and can directly provide explicit lung regions without any post-processing operations compared to the standard method.

Keywords: graph cuts, lung CT scan, lung parenchyma segmentation, patch-based similarity metric

Procedia PDF Downloads 153
6105 Capital Punishment as a Contradiction to International Law and Indonesian Constitution

Authors: Akbar

Abstract:

Pros and cons of the capital punishment in Indonesia have been out of the date. The discourse of capital punishment has no relevance to the theory of punishment and theories of cultural relativism. In fact, the provisions of exceptions to the right to life by administering the death penalty against the perpetrators of serious crimes in Indonesia is a narrow perspective that does not pay attention to the development of the punishment of the crime. This thing is aggravated by an error to understand the natural right and legal right where the prohibition of those rights is result from a failure to distinguish the characteristic of the rights and to remember the raison d’être of law. To parse the irrational above, this paper will try to analyze normatively the error referring to the complementary theory between the sources of international law and the sources of municipal law of Indonesia. Both sources of the law above should be understood in the mutually reinforcing relationship enforceability because of false perceptions against those will create the disintegration between international law and municipal law of Indonesia. This disintegration is explicit not only contrary to the integrative theory of international law but also integrative theory of municipal law of Indonesia.

Keywords: capital punishment, municipal law, right to life, international law, the raison d’être of law, complementary theory, integrative theory

Procedia PDF Downloads 325
6104 Bit Error Rate Monitoring for Automatic Bias Control of Quadrature Amplitude Modulators

Authors: Naji Ali Albakay, Abdulrahman Alothaim, Isa Barshushi

Abstract:

The most common quadrature amplitude modulator (QAM) applies two Mach-Zehnder Modulators (MZM) and one phase shifter to generate high order modulation format. The bias of MZM changes over time due to temperature, vibration, and aging factors. The change in the biasing causes distortion to the generated QAM signal which leads to deterioration of bit error rate (BER) performance. Therefore, it is critical to be able to lock MZM’s Q point to the required operating point for good performance. We propose a technique for automatic bias control (ABC) of QAM transmitter using BER measurements and gradient descent optimization algorithm. The proposed technique is attractive because it uses the pertinent metric, BER, which compensates for bias drifting independently from other system variations such as laser source output power. The proposed scheme performance and its operating principles are simulated using OptiSystem simulation software for 4-QAM and 16-QAM transmitters.

Keywords: automatic bias control, optical fiber communication, optical modulation, optical devices

Procedia PDF Downloads 174
6103 Frequency of Consonant Production Errors in Children with Speech Sound Disorder: A Retrospective-Descriptive Study

Authors: Amulya P. Rao, Prathima S., Sreedevi N.

Abstract:

Speech sound disorders (SSD) encompass the major concern in younger population of India with highest prevalence rate among the speech disorders. Children with SSD if not identified and rehabilitated at the earliest, are at risk for academic difficulties. This necessitates early identification using screening tools assessing the frequently misarticulated speech sounds. The literature on frequently misarticulated speech sounds is ample in English and other western languages targeting individuals with various communication disorders. Articulation is language specific, and there are limited studies reporting the same in Kannada, a Dravidian Language. Hence, the present study aimed to identify the frequently misarticulated consonants in Kannada and also to examine the error type. A retrospective, descriptive study was carried out using secondary data analysis of 41 participants (34-phonetic type and 7-phonemic type) with SSD in the age range 3-to 12-years. All the consonants of Kannada were analyzed by considering three words for each speech sound from the Kannada Diagnostic Photo Articulation test (KDPAT). Picture naming task was carried out, and responses were audio recorded. The recorded data were transcribed using IPA 2018 broad transcription. A criterion of 2/3 or 3/3 error productions was set to consider the speech sound to be an error. Number of error productions was calculated for each consonant in each participant. Then, the percentage of participants meeting the criteria were documented for each consonant to identify the frequently misarticulated speech sound. Overall results indicated that velar /k/ (48.78%) and /g/ (43.90%) were frequently misarticulated followed by voiced retroflex /ɖ/ (36.58%) and trill /r/ (36.58%). The lateral retroflex /ɭ/ was misarticulated by 31.70% of the children with SSD. Dentals (/t/, /n/), bilabials (/p/, /b/, /m/) and labiodental /v/ were produced correctly by all the participants. The highly misarticulated velars /k/ and /g/ were frequently substituted by dentals /t/ and /d/ respectively or omitted. Participants with SSD-phonemic type had multiple substitutions for one speech sound whereas, SSD-phonetic type had consistent single sound substitutions. Intra- and inter-judge reliability for 10% of the data using Cronbach’s Alpha revealed good reliability (0.8 ≤ α < 0.9). Analyzing a larger sample by replicating such studies will validate the present study results.

Keywords: consonant, frequently misarticulated, Kannada, SSD

Procedia PDF Downloads 107
6102 Influence of Tactile Symbol Size on Its Perceptibility in Consideration of Effect of Aging

Authors: T. Nishimura, K. Doi, H. Fujimoto, T. Wada

Abstract:

We conducted perception experiments on tactile symbols to elucidate the impact of the size of these letters on the level of perceptibility. This study was based on the accessible design perspective and aimed at expanding the availability of tactile symbols for the visually impaired who are unable to read Braille characters. In particular, this study targeted people with acquired visual impairments as users of the tactile symbols. The subjects (young and elderly individuals) in this study had normal vision. They were asked to participate in the experiments to identify tactile symbols while unable to see their hand during the experiments. This study investigated the relation between the size and perceptibility of tactile symbols based on an examination using test pieces of these letters in different sizes. The results revealed that the error rates for both young and elderly subjects converged to almost 0% when 12 mm size tactile symbols were used. The findings also showed that the error rate was low and subjects could identify the symbols in 5 s when 16 mm size tactile symbols were introduced.

Keywords: accessible design, tactile sense, tactile symbols, bioinformatic

Procedia PDF Downloads 329
6101 Comparing the SALT and START Triage System in Disaster and Mass Casualty Incidents: A Systematic Review

Authors: Hendri Purwadi, Christine McCloud

Abstract:

Triage is a complex decision-making process that aims to categorize a victim’s level of acuity and the need for medical assistance. Two common triage systems have been widely used in Mass Casualty Incidents (MCIs) and disaster situation are START (Simple triage algorithm and rapid treatment) and SALT (sort, asses, lifesaving, intervention, and treatment/transport). There is currently controversy regarding the effectiveness of SALT over START triage system. This systematic review aims to investigate and compare the effectiveness between SALT and START triage system in disaster and MCIs setting. Literatures were searched via systematic search strategy from 2009 until 2019 in PubMed, Cochrane Library, CINAHL, Scopus, Science direct, Medlib, ProQuest. This review included simulated-based and medical record -based studies investigating the accuracy and applicability of SALT and START triage systems of adult and children population during MCIs and disaster. All type of studies were included. Joana Briggs institute critical appraisal tools were used to assess the quality of reviewed studies. As a result, 1450 articles identified in the search, 10 articles were included. Four themes were identified by review, they were accuracy, under-triage, over-triage and time to triage per individual victim. The START triage system has a wide range and inconsistent level of accuracy compared to SALT triage system (44% to 94. 2% of START compared to 70% to 83% of SALT). The under-triage error of START triage system ranged from 2.73% to 20%, slightly lower than SALT triage system (7.6 to 23.3%). The over-triage error of START triage system was slightly greater than SALT triage system (START ranged from 2% to 53% compared to 2% to 22% of SALT). The time for applying START triage system was faster than SALT triage system (START was 70-72.18 seconds compared to 78 second of SALT). Consequently; The START triage system has lower level of under-triage error and faster than SALT triage system in classifying victims of MCIs and disaster whereas SALT triage system is known slightly more accurate and lower level of over-triage. However, the magnitude of these differences is relatively small, and therefore the effect on the patient outcomes is not significance. Hence, regardless of the triage error, either START or SALT triage system is equally effective to triage victims of disaster and MCIs.

Keywords: disaster, effectiveness, mass casualty incidents, START triage system, SALT triage system

Procedia PDF Downloads 117
6100 Integrating Deterministic and Probabilistic Safety Assessment to Decrease Risk & Energy Consumption in a Typical PWR

Authors: Ebrahim Ghanbari, Mohammad Reza Nematollahi

Abstract:

Integrating deterministic and probabilistic safety assessment (IDPSA) is one of the most commonly used issues in the field of safety analysis of power plant accident. It has also been recognized today that the role of human error in creating these accidents is not less than systemic errors, so the human interference and system errors in fault and event sequences are necessary. The integration of these analytical topics will be reflected in the frequency of core damage and also the study of the use of water resources in an accident such as the loss of all electrical power of the plant. In this regard, the SBO accident was simulated for the pressurized water reactor in the deterministic analysis issue, and by analyzing the operator's behavior in controlling the accident, the results of the combination of deterministic and probabilistic assessment were identified. The results showed that the best performance of the plant operator would reduce the risk of an accident by 10%, as well as a decrease of 6.82 liters/second of the water sources of the plant.

Keywords: IDPSA, human error, SBO, risk

Procedia PDF Downloads 112
6099 A Hybrid Data-Handler Module Based Approach for Prioritization in Quality Function Deployment

Authors: P. Venu, Joeju M. Issac

Abstract:

Quality Function Deployment (QFD) is a systematic technique that creates a platform where the customer responses can be positively converted to design attributes. The accuracy of a QFD process heavily depends on the data that it is handling which is captured from customers or QFD team members. Customized computer programs that perform Quality Function Deployment within a stipulated time have been used by various companies across the globe. These programs heavily rely on storage and retrieval of the data on a common database. This database must act as a perfect source with minimum missing values or error values in order perform actual prioritization. This paper introduces a missing/error data handler module which uses Genetic Algorithm and Fuzzy numbers. The prioritization of customer requirements of sesame oil is illustrated and a comparison is made between proposed data handler module-based deployment and manual deployment.

Keywords: hybrid data handler, QFD, prioritization, module-based deployment

Procedia PDF Downloads 282
6098 Satellite Image Classification Using Firefly Algorithm

Authors: Paramjit Kaur, Harish Kundra

Abstract:

In the recent years, swarm intelligence based firefly algorithm has become a great focus for the researchers to solve the real time optimization problems. Here, firefly algorithm is used for the application of satellite image classification. For experimentation, Alwar area is considered to multiple land features like vegetation, barren, hilly, residential and water surface. Alwar dataset is considered with seven band satellite images. Firefly Algorithm is based on the attraction of less bright fireflies towards more brightener one. For the evaluation of proposed concept accuracy assessment parameters are calculated using error matrix. With the help of Error matrix, parameters of Kappa Coefficient, Overall Accuracy and feature wise accuracy parameters of user’s accuracy & producer’s accuracy can be calculated. Overall results are compared with BBO, PSO, Hybrid FPAB/BBO, Hybrid ACO/SOFM and Hybrid ACO/BBO based on the kappa coefficient and overall accuracy parameters.

Keywords: image classification, firefly algorithm, satellite image classification, terrain classification

Procedia PDF Downloads 383
6097 Lexical-Semantic Processing by Chinese as a Second Language Learners

Authors: Yi-Hsiu Lai

Abstract:

The present study aimed to elucidate the lexical-semantic processing for Chinese as second language (CSL) learners. Twenty L1 speakers of Chinese and twenty CSL learners in Taiwan participated in a picture naming task and a category fluency task. Based on their Chinese proficiency levels, these CSL learners were further divided into two sub-groups: ten CSL learners of elementary Chinese proficiency level and ten CSL learners of intermediate Chinese proficiency level. Instruments for the naming task were sixty black-and-white pictures: thirty-five object pictures and twenty-five action pictures. Object pictures were divided into two categories: living objects and non-living objects. Action pictures were composed of two categories: action verbs and process verbs. As in the naming task, the category fluency task consisted of two semantic categories – objects (i.e., living and non-living objects) and actions (i.e., action and process verbs). Participants were asked to report as many items within a category as possible in one minute. Oral productions were tape-recorded and transcribed for further analysis. Both error types and error frequency were calculated. Statistical analysis was further conducted to examine these error types and frequency made by CSL learners. Additionally, category effects, pictorial effects and L2 proficiency were discussed. Findings in the present study helped characterize the lexical-semantic process of Chinese naming in CSL learners of different Chinese proficiency levels and made contributions to Chinese vocabulary teaching and learning in the future.

Keywords: lexical-semantic processing, Mandarin Chinese, naming, category effects

Procedia PDF Downloads 446
6096 Factors of Influence in Software Process Improvement: An ISO/IEC 29110 for Very-Small Entities

Authors: N. Wongsai, R. Wetprasit, V. Siddoo

Abstract:

The recently introduced ISO/IEC 29110 standard Lifecycle profile for Very Small Entities (VSE) has been adopted and practiced in many small and medium software companies, including in Thailand’s software industry. Many Thai companies complete their software process improvement (SPI) initiative program and have been certified. There are, however, a number of participants fail to success. This study was concerned with the factors that influence the accomplishment of the standard implementation in various VSE characteristics. In order to achieve this goal, exploring and extracting critical factors from prior studies were carried out and then the obtained factors were validated by the standard experts. Data analysis of comments and recommendations was performed using a qualitative content analysis method. This paper presents the initial set of influence factors in both positive and negative impact the ISO/IEC 29110 implementation with an aim at helping such SPI practitioners with some considerations to manage appropriate adoption approach in order to achieve its implementation.

Keywords: barriers, critical success factors, ISO/IEC 29110, Software Process Improvement, SPI, Very-Small Entity, VSE

Procedia PDF Downloads 299
6095 Protective Effects of Vitamin C and Vitamin E on Experimentally Induced Testicular Torsion and Detorsion in Rat Model

Authors: Anu Vinod Ranade

Abstract:

Aim: To evaluate and compare the effects of Vitamin C and Vitamin E on experimentally induced testicular torsion and detorsion in rats. Methods: Forty Male Wistar Albino rats were divided into five groups. Animals in the Group I underwent Sham operation, Group II consisted of animals that were subjected to torsion for three hours followed by detorsion for 24 hours without any treatment. While Group III, IV and V were orally pretreated with Vitamin C (40mg/kg.bw), vitamin E (100mg/kg.bw) and a combination of Vitamin C and vitamin E respectively for a period of 30 days. The testes of the experimental groups were manually rotated to 720° clockwise for three hours and counter rotated for 24 hours to induce ischemia and reperfusion. Sequential biopsies were performed and the testes were collected at the end of 24 hours of detrosion for morphological evaluation. Result: There was a significant decrease in the standard tubular diameter and the epithelial height of the seminiferous tubules in the untreated group when compared to Sham controls. The standard tubular diameter and seminiferous epithelial height showed near normal values when animals were pretreated with Vitamin C and Vitamin E individually or in combination. Conclusion: The results showed that pretreatment of with antioxidants vitamin E and vitamin C when administered prior to testicular torsion in rats significantly reduced the torsion and detorsion induced histopathlogical injury.

Keywords: vitamin C, vitamin E, standard tubular diameter, standard epithelial height, testicular torsion

Procedia PDF Downloads 303
6094 Position and Speed Tracking of DC Motor Based on Experimental Analysis in LabVIEW

Authors: Muhammad Ilyas, Awais Khan, Syed Ali Raza Shah

Abstract:

DC motors are widely used in industries to provide mechanical power in speed and torque. The position and speed control of DC motors is getting the interest of the scientific community in robotics, especially in the robotic arm, a flexible joint manipulator. The current research work is based on position control of DC motors using experimental investigations in LabVIEW. The linear control strategy is applied to track the position and speed of the DC motor with comparative analysis in the LabVIEW platform and simulation analysis in MATLAB. The tracking error in hardware setup based on LabVIEW programming is slightly greater than simulation analysis in MATLAB due to the inertial load of the motor during steady-state conditions. The controller output shows the input voltage applied to the dc motor varies between 0-8V to ensure minimal steady error while tracking the position and speed of the DC motor.

Keywords: DC motor, labview, proportional integral derivative control, position tracking, speed tracking

Procedia PDF Downloads 86
6093 Signal Processing Techniques for Adaptive Beamforming with Robustness

Authors: Ju-Hong Lee, Ching-Wei Liao

Abstract:

Adaptive beamforming using antenna array of sensors is useful in the process of adaptively detecting and preserving the presence of the desired signal while suppressing the interference and the background noise. For conventional adaptive array beamforming, we require a prior information of either the impinging direction or the waveform of the desired signal to adapt the weights. The adaptive weights of an antenna array beamformer under a steered-beam constraint are calculated by minimizing the output power of the beamformer subject to the constraint that forces the beamformer to make a constant response in the steering direction. Hence, the performance of the beamformer is very sensitive to the accuracy of the steering operation. In the literature, it is well known that the performance of an adaptive beamformer will be deteriorated by any steering angle error encountered in many practical applications, e.g., the wireless communication systems with massive antennas deployed at the base station and user equipment. Hence, developing effective signal processing techniques to deal with the problem due to steering angle error for array beamforming systems has become an important research work. In this paper, we present an effective signal processing technique for constructing an adaptive beamformer against the steering angle error. The proposed array beamformer adaptively estimates the actual direction of the desired signal by using the presumed steering vector and the received array data snapshots. Based on the presumed steering vector and a preset angle range for steering mismatch tolerance, we first create a matrix related to the direction vector of signal sources. Two projection matrices are generated from the matrix. The projection matrix associated with the desired signal information and the received array data are utilized to iteratively estimate the actual direction vector of the desired signal. The estimated direction vector of the desired signal is then used for appropriately finding the quiescent weight vector. The other projection matrix is set to be the signal blocking matrix required for performing adaptive beamforming. Accordingly, the proposed beamformer consists of adaptive quiescent weights and partially adaptive weights. Several computer simulation examples are provided for evaluating and comparing the proposed technique with the existing robust techniques.

Keywords: adaptive beamforming, robustness, signal blocking, steering angle error

Procedia PDF Downloads 110
6092 Simulation as a Problem-Solving Spotter for System Reliability

Authors: Wheyming Tina Song, Chi-Hao Hong, Peisyuan Lin

Abstract:

An important performance measure for stochastic manufacturing networks is the system reliability, defined as the probability that the production output meets or exceeds a specified demand. The system parameters include the capacity of each workstation and numbers of the conforming parts produced in each workstation. We establish that eighteen archival publications, containing twenty-one examples, provide incorrect values of the system reliability. The author recently published the Song Rule, which provides the correct analytical system-reliability value; it is, however, computationally inefficient for large networks. In this paper, we use Monte Carlo simulation (implemented in C and Flexsim) to provide estimates for the above-mentioned twenty-one examples. The simulation estimates are consistent with the analytical solution for small networks but is computationally efficient for large networks. We argue here for three advantages of Monte Carlo simulation: (1) understanding stochastic systems, (2) validating analytical results, and (3) providing estimates even when analytical and numerical approaches are overly expensive in computation. Monte Carlo simulation could have detected the published analysis errors.

Keywords: Monte Carlo simulation, analytical results, leading digit rule, standard error

Procedia PDF Downloads 342