Search results for: image-guided radiotherapy megavoltage computed tomography
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1208

Search results for: image-guided radiotherapy megavoltage computed tomography

788 Adjustment of the Level of Vibrational Force on Targeted Teeth

Authors: Amin Akbari, Dongcai Wang, Huiru Li, Xiaoping Du, Jie Chen

Abstract:

The effect of vibrational force (VF) on accelerating orthodontic tooth movement depends on the level of delivered stimulation to the tooth in terms of peak load (PL), which requires contacts between the tooth and the VF device. A personalized device ensures the contacts, but the resulting PL distribution on the teeth is unknown. Furthermore, it is unclear whether the PL on particular teeth can be adjusted to the prescribed values. The objective of this study was to investigate the efficacy of apersonalized VF device in controlling the level of stimulation on two teeth, the mandibular canines and 2nd molars. A 3-D finite element (FE) model of human dentition, including teeth, PDL, and alveolar bone, was created from the cone beam computed tomography images of an anonymous subject. The VF was applied to the teeth through a VFdevice consisting of a mouthpiece with engraved tooth profile of the subject and a VF source that applied 0.3 N force with the frequency of 30 Hz. The dentition and mouthpiece were meshed using 10-node tetrahedral elements. Interface elements were created at the interfaces between the teeth and the mouthpiece. The upper and lower teeth bite on the mouthpiece to receive the vibration. The depth of engraved individual tooth profile could be adjusted, which was accomplished by adding a layer of material as an interference or removing a layer of material as a clearance to change the PL on the tooth. The interference increases the PL while the clearance decreases it. Fivemouthpiece design cases were simulated, which included a mouthpiece without interference/clearance; the mouthpieces with bilateral interferences on both mandibular canines and 2nd molars with magnitudes of 0.1, 0.15, and 0.2-mm, respectively; and mouthpiece with bilateral 0.3-mm clearances on the four teeth. Then, the force distributions on the entire dentition were compared corresponding to these adjustments. The PL distribution on the teeth is uneven when there is no interference or clearance. Among all teeth, the anterior segment receives the highest level of PL. Adding 0.1, 0.15, and 0.2-mm interferences to the canines and 2nd molars bilaterally leads to increase of the PL on the canines by 10, 62, and 73 percent and on the 2nd molar by 14, 55, and 87 percent, respectively. Adding clearances to the canines and 2nd molars by removing the contactsbetween these teeth and the mouthpiece results in zero PL on them. Moreover, introducing interference to mandibular canines and 2nd molarsredistributes the PL on the entireteeth. The share of the PL on the anterior teeth are reduced. The use of the personalized mouthpiece ensures contactsof the teeth to the mouthpiece so that all teeth can be stimulated. However, the PL distribution is uneven. Adding interference between a tooth and the mouthpiece increases the PL while introducing clearance decreases the PL. As a result, the PL is redistributed. This study confirms that the level of VF stimulation on the individual tooth can be adjusted to a prescribed value.

Keywords: finite element method, orthodontic treatment, stress analysis, tooth movement, vibrational force

Procedia PDF Downloads 221
787 Penetrating Neck Injury: No Zone Approach

Authors: Abhishek Sharma, Amit Gupta, Manish Singhal

Abstract:

Background: The management of patients with penetrating neck injuries in the prehospital setting and in the emergency department has evolved with regard to the use of multidetector computed tomographic (MDCT) imaging. Hence, there is a shift in the management of neck injuries from mandatory exploration in certain anatomic areas to more conservative approach using imaging and so-called “no zone approach”. Objective: To study the no zone approach in the management of penetrating neck injury using routine imaging in all stable patients. Methods: 137 patients with penetrating neck injury attending emergency department of level 1 trauma centre at AIIMS between 2008–2014 were retrospectively analysed. All hemodynamically stable patients were evaluated using CT scanning. Results: Stab injury is most common (55.91%) mode of pni in civilian population followed by gunshot(18.33%). The majority of patients could be managed with imaging and close observation. 39 patients (28.46%) required operative intervention. The most common indication for operative intervention was vascular followed by airway injury manifesting as hemodynamic destabilisation.There was no statistical difference between the zonal distribution of injuries in patients managed conservatively and those taken to OR. Conclusions: Study shows that patients with penetrating neck trauma who are haemodynamically stable and exhibit no “hard signs” of vascular injury or airway injury may be evaluated initially by MDCT imaging even when platysma violation is present. “No Zone” policy may be superior to traditional zone wise management.

Keywords: penetrating neck injury, zone approach, CT scanning, multidetector computed tomographic (MDCT)

Procedia PDF Downloads 399
786 Pre-Implementation of Total Body Irradiation Using Volumetric Modulated Arc Therapy: Full Body Anthropomorphic Phantom Development

Authors: Susana Gonçalves, Joana Lencart, Anabela Gregório Dias

Abstract:

Introduction: In combination with chemotherapy, Total Body Irradiation (TBI) is most used as part of the conditioning regimen prior to allogeneic hematopoietic stem cell transplantation. Conventional TBI techniques have a long application time but non-conformality of beam-application with the inability to individually spare organs at risk. Our institution’s intention is to start using Volumetric Modulated Arc Therapy (VMAT) techniques to increase homogeneity of delivered radiation. As a first approach, a dosimetric plan was performed on a computed tomography (CT) scan of a Rando Alderson antropomorfic phantom (head and torso), using a set of six arcs distributed along the phantom. However, a full body anthropomorphic phantom is essential to carry out technique validation and implementation. Our aim is to define the physical and chemical characteristics and the ideal manufacturing procedure of upper and lower limbs to our anthropomorphic phantom, for later validate TBI using VMAT. Materials and Methods: To study the better fit between our phantom and limbs, a CT scan of Rando Alderson anthropomorphic phantom was acquired. CT was performed on GE Healthcare equipment (model Optima CT580 W), with slice thickness of 2.5 mm. This CT was also used to access the electronic density of soft tissue and bone through Hounsfield units (HU) analysis. Results: CT images were analyzed and measures were made for the ideal upper and lower limbs. Upper limbs should be build under the following measures: 43cm length and 7cm diameter (next to the shoulder section). Lower limbs should be build under the following measures: 79cm length and 16.5cm diameter (next to the thigh section). As expected, soft tissue and bone have very different electronic density. This is important to choose and analyze different materials to better represent soft tissue and bone characteristics. The approximate HU values of the soft tissue and for bone shall be 35HU and 250HU, respectively. Conclusion: At the moment, several compounds are being developed based on different types of resins and additives in order to be able to control and mimic the various constituent densities of the tissues. Concurrently, several manufacturing techniques are being explored to make it possible to produce the upper and lower limbs in a simple and non-expensive way, in order to finally carry out a systematic and appropriate study of the total body irradiation. This preliminary study was a good starting point to demonstrate the feasibility of TBI with VMAT.

Keywords: TBI, VMAT, anthropomorphic phantom, tissue equivalent materials

Procedia PDF Downloads 74
785 Rural Water Supply Services in India: Developing a Composite Summary Score

Authors: Mimi Roy, Sriroop Chaudhuri

Abstract:

Sustainable water supply is among the basic needs for human development, especially in the rural areas of the developing nations where safe water supply and basic sanitation infrastructure is direly needed. In light of the above, we propose a simple methodology to develop a composite water sustainability index (WSI) to assess the collective performance of the existing rural water supply services (RWSS) in India over time. The WSI will be computed by summarizing the details of all the different varieties of water supply schemes presently available in India comprising of 40 liters per capita per day (lpcd), 55 lpcd, and piped water supply (PWS) per household. The WSI will be computed annually, between 2010 and 2016, to elucidate changes in holistic RWSS performances. Results will be integrated within a robust geospatial framework to identify the ‘hotspots’ (states/districts) which have persistent issues over adequate RWSS coverage and warrant spatially-optimized policy reforms in future to address sustainable human development. Dataset will be obtained from the National Rural Drinking Water Program (NRDWP), operating under the aegis of the Ministry of Drinking Water and Sanitation (MoDWS), at state/district/block levels to offer the authorities a cross-sectional view of RWSS at different levels of administrative hierarchy. Due to simplistic design, complemented by spatio-temporal cartograms, similar approaches can also be adopted in other parts of the world where RWSS need a thorough appraisal.

Keywords: rural water supply services, piped water supply, sustainability, composite index, spatial, drinking water

Procedia PDF Downloads 292
784 The Effect of Deformation Activation Volume, Strain Rate Sensitivity and Processing Temperature of Grain Size Variants

Authors: P. B. Sob, A. A. Alugongo, T. B. Tengen

Abstract:

The activation volume of 6082T6 aluminum is investigated at different temperatures on grain size variants. The deformation activation volume was computed on the basis of the relationship between the Boltzmann’s constant k, the testing temperatures, the material strain rate sensitivity and the material yield stress of grain size variants. The material strain rate sensitivity is computed as a function of yield stress and strain rate of grain size variants. The effect of the material strain rate sensitivity and the deformation activation volume of 6082T6 aluminum at different temperatures of 3-D grain are discussed. It is shown that the strain rate sensitivities and activation volume are negative for the grain size variants during the deformation of nanostructured materials. It is also observed that the activation volume vary in different ways with the equivalent radius, semi minor axis radius, semi major axis radius and major axis radius. From the obtained results it is shown that the variation of activation volume increased and decreased with the testing temperature. It was revealed that, increased in strain rate sensitivity led to decrease in activation volume whereas increased in activation volume led to decrease in strain rate sensitivity.

Keywords: nanostructured materials, grain size variants, temperature, yield stress, strain rate sensitivity, activation volume

Procedia PDF Downloads 246
783 An Insight into Early Stage Detection of Malignant Tumor by Microwave Imaging

Authors: Muhammad Hassan Khalil, Xu Jiadong

Abstract:

Detection of malignant tumor inside the breast of women is a challenging field for the researchers. MWI (Microwave imaging) for breast cancer diagnosis has been of interest for last two decades, newly it suggested for finding cancerous tissues of women breast. A simple and basic idea of the mathematical modeling is used throughout this paper for imaging of malignant tumor. In this paper, the authors explained inverse scattering method in the microwave imaging and also present some simulation results.

Keywords: breast cancer detection, microwave imaging, tomography, tumor

Procedia PDF Downloads 405
782 Intensive Care Unit Patient Self-Determination When Facing Cardiovascular Surgery for the First Time

Authors: Hsiao-Lin Fang

Abstract:

The Patient Self-Determination Act is based on the belief that each life is unique. The act regards each patient as an autonomous entity and explicitly protects the patient’s rights to know and make decisions and choices while ensuring that the patient’s wish for a peaceful end is granted. Even when the patient is unconscious and unable to express himself/herself, the patient’s self-determination and its exercise are still protected under the law. The act also ensures that healthcare professionals (HCPs) have a specific set of rules to follow and complete legal protection when their patients are unable to express themselves clearly. This report is about a 55-year-old female patient who weighed 110 kg and was diagnosed with acute type A aortic dissection. The case was that the patient suddenly felt backache and nausea during sleep before daybreak and was therefore transferred to this hospital from the original one. After the doctor explained the patient’s conditions, it was concluded that surgery was necessary. However, the patient’s family was immediately against the surgery after having heard its possible complications. Nevertheless, the patient was still willing to receive the surgery. Being at odds with her family, the patient decided to sign the surgery agreement herself and agreed to receive the two surgical procedures: (1) ascending aorta replacement and (2) innominate artery debranching. After the surgery, the patient did not regain consciousness and therefore received computed tomography scanning of the brain, which revealed false lumen involving proximal left common carotid artery, left subclavian artery and innominate artery, and severe compression of the true lumen with total/subtotal occlusion in the left common carotid artery. On the following day, the doctor discussed two further surgical procedures: (1) endografting for descending aorta and (2) endografting for left common carotid artery and subclavian artery with the family. However, as the patient’s postoperative recovery of consciousness only reached the level of stupor and her family had no intention of subsequent healthcare for the patient, the family made the joint decision three days later to have the endotracheal tube removed from the patient and let her die a natural death. Suggestion: An advance directive (AD) can be created beforehand. Once the patient is in a special clinical state (e.g., terminal illness, permanent vegetative state, etc.), the AD can determine whether to sustain the patient’s life through ‘medical intervention’ or to respect the patient’s rights to choose a peaceful end and receive palliative care. Through the expression of self-determination, it is possible to respect the patient’s medical practice autonomy and protect the patient’s dignity and right to a peaceful end, thereby respecting and supporting the patient’s decision. This also allows the three sides: the patient, the family and the medical team to understand the patient’s true wish in the process of advance care planning (ACP) and thereby promote harmony in the HCP-patient relationship.

Keywords: intensive care unit patient, cardiovascular surgery, self-determination, advance directive

Procedia PDF Downloads 170
781 Determination of the Informativeness of Instrumental Research Methods in Assessing Risk Factors for the Development of Renal Dysfunction in Elderly Patients with Chronic Ischemic Heart Disease

Authors: Aksana N. Popel, Volha A. Sujayeva, Olga V. Kоshlataja, Irеna S. Karpava

Abstract:

Introduction: It is a known fact that cardiovascular pathology and its complications cause a more severe course and worse prognosis in patients with comorbid kidney pathology. Chronic kidney disease (CKD) is associated with inflammation, endothelial dysfunction, and increased activity of the sympathoadrenal system. This circumstance increases the risk of cardiovascular diseases and the progression of kidney pathology. The above determines the need to identify cardiorenal changes at early stages to reduce the risks of cardiovascular complications and the progression of CKD. Objective: To identify risk factors (RF) for the development of CKD in elderly patients with chronic ischemic heart disease (CIHD). Methods: The study included 64 patients (40 women and 24 men) with a mean age of 74.4±4.5 years with coronary heart disease, without a history of structural kidney pathology and CKD. All patients underwent transthoracic echocardiography (TTE) and kidney ultrasound (KU) using GE Vivid 9 equipment (GE HealthCare, USA), and cardiac computed tomography (CCT) using Siemens Somatom Force equipment (Siemens Healthineers AG, Germany) in 3 months and in 1 year. Data obtained were analyzed using multiple regression analysis and nonparametric Mann-Whitney test. Statistical analysis was performed using the STATISTICA 12.0 program (StatSoft Inc.). Results: Initially, CKD was not diagnosed in all patients. In 3 months, CKD was diagnosed: stage C1 had 11 people (18%), stage C2 had 4 people (6%), stage C3A had 11 people (18%), stage C3B had 2 people (3%). After 1 year, CKD was diagnosed: stage C1 had 22 people (35%), stage C2 had 5 people (8%), stage C3A had 17 people (27%), stage C3B had 10 people (15%). In 3 months, statistically significant (p<0.05) risk factors were: 1) according to TTE: mitral peak E-wave velocity (U=678, p=0.039), mitral E-velocity DT (U=514, p=0.0168), mitral peak A-wave velocity (U=682, p=0.013). In 1 year, statistically significant (p<0.05) risk factors were: according to TTE: left ventricular (LV) end-systolic volume in B-mode (U=134, p=0.006), LV end-diastolic volume in B-mode (U=177, p=0.04), LV ejection fraction in B-mode (U=135, p=0.006), left atrial volume (U=178, p=0.021), LV hypertrophy (U=294, p=0.04), mitral valve (MV) fibrosis (U=328, p=0.01); according CCT: epicardial fat thickness (EFT) on the right ventricle (U=8, p=0.015); according to KU: interlobar renal artery resistance index (RI) (U=224, p=0.02), segmental renal artery RI (U=409, p=0.016). Conclusions: Both TTE and KU are very informative methods to determine the additional risk factors of CKD development and progression. The most informative risk factors were LV global systolic and diastolic functions, LV and LA volumes. LV hypertrophy, MV fibrosis, interlobar renal artery and segmental renal artery RIs, EFT.

Keywords: chronic kidney disease, ischemic heart disease, prognosis, risk factors

Procedia PDF Downloads 11
780 Management of Caverno-Venous Leakage: A Series of 133 Patients with Symptoms, Hemodynamic Workup, and Results of Surgery

Authors: Allaire Eric, Hauet Pascal, Floresco Jean, Beley Sebastien, Sussman Helene, Virag Ronald

Abstract:

Background: Caverno-venous leakage (CVL) is devastating, although barely known disease, the first cause of major physical impairment in men under 25, and responsible for 50% of resistances to phosphodiesterase 5-inhibitors (PDE5-I), affecting 30 to 40% of users in this medication class. In this condition, too early blood drainage from corpora cavernosa prevents penile rigidity and penetration during sexual intercourse. The role of conservative surgery in this disease remains controversial. Aim: Assess complications and results of combined open surgery and embolization for CVL. Method: Between June 2016 and September 2021, 133 consecutive patients underwent surgery in our institution for CVL, causing severe erectile dysfunction (ED) resistance to oral medical treatment. Procedures combined vein embolization and ligation with microsurgical techniques. We performed a pre-and post-operative clinical (Erection Harness Scale: EHS) hemodynamic evaluation by duplex sonography in all patients. Before surgery, the CVL network was visualized by computed tomography cavernography. Penile EMG was performed in case of diabetes or suspected other neurological conditions. All patients were optimized for hormonal status—data we prospectively recorded. Results: Clinical signs suggesting CVL were ED since age lower than 25, loss of erection when changing position, penile rigidity varying according to the position. Main complications were minor pulmonary embolism in 2 patients, one after airline travel, one with Factor V Leiden heterozygote mutation, one infection and three hematomas requiring reoperation, one decreased gland sensitivity lasting for more than one year. Mean pre-operative pharmacologic EHS was 2.37+/-0.64, mean pharmacologic post-operative EHS was 3.21+/-0.60, p<0.0001 (paired t-test). The mean EHS variation was 0.87+/-0.74. After surgery, 81.5% of patients had a pharmacologic EHS equal to or over 3, allowing for intercourse with penetration. Three patients (2.2%) experienced lower post-operative EHS. The main cause of failure was leakage from the deep dorsal aspect of the corpus cavernosa. In a 14 months follow-up, 83.2% of patients had a clinical EHS equal to or over 3, allowing for sexual intercourse with penetration, one-third of them without any medication. 5 patients had a penile implant after unsuccessful conservative surgery. Conclusion: Open surgery combined with embolization for CVL is an efficient approach to CVL causing severe erectile dysfunction.

Keywords: erectile dysfunction, cavernovenous leakage, surgery, embolization, treatment, result, complications, penile duplex sonography

Procedia PDF Downloads 142
779 HRCT of the Chest and the Role of Artificial Intelligence in the Evaluation of Patients with COVID-19

Authors: Parisa Mansour

Abstract:

Introduction: Early diagnosis of coronavirus disease (COVID-19) is extremely important to isolate and treat patients in time, thus preventing the spread of the disease, improving prognosis and reducing mortality. High-resolution computed tomography (HRCT) chest imaging and artificial intelligence (AI)-based analysis of HRCT chest images can play a central role in the treatment of patients with COVID-19. Objective: To investigate different chest HRCT findings in different stages of COVID-19 pneumonia and to evaluate the potential role of artificial intelligence in the quantitative assessment of lung parenchymal involvement in COVID-19 pneumonia. Materials and Methods: This retrospective observational study was conducted between May 1, 2020 and August 13, 2020. The study included 2169 patients with COVID-19 who underwent chest HRCT. HRCT images showed the presence and distribution of lesions such as: ground glass opacity (GGO), compaction, and any special patterns such as septal thickening, inverted halo, mark, etc. HRCT findings of the breast at different stages of the disease (early: andlt) 5 days, intermediate: 6-10 days and late stage: >10 days). A CT severity score (CTSS) was calculated based on the extent of lung involvement on HRCT, which was then correlated with clinical disease severity. Use of artificial intelligence; Analysis of CT pneumonia and quot; An algorithm was used to quantify the extent of pulmonary involvement by calculating the percentage of pulmonary opacity (PO) and gross opacity (PHO). Depending on the type of variables, statistically significant tests such as chi-square, analysis of variance (ANOVA) and post hoc tests were applied when appropriate. Results: Radiological findings were observed in HRCT chest in 1438 patients. A typical pattern of COVID-19 pneumonia, i.e., bilateral peripheral GGO with or without consolidation, was observed in 846 patients. About 294 asymptomatic patients were radiologically positive. Chest HRCT in the early stages of the disease mostly showed GGO. The late stage was indicated by such features as retinal enlargement, thickening and the presence of fibrous bands. Approximately 91.3% of cases with a CTSS = 7 were asymptomatic or clinically mild, while 81.2% of cases with a score = 15 were clinically severe. Mean PO and PHO (30.1 ± 28.0 and 8.4 ± 10.4, respectively) were significantly higher in the clinically severe categories. Conclusion: Because COVID-19 pneumonia progresses rapidly, radiologists and physicians should become familiar with typical TC chest findings to treat patients early, ultimately improving prognosis and reducing mortality. Artificial intelligence can be a valuable tool in treating patients with COVID-19.

Keywords: chest, HRCT, covid-19, artificial intelligence, chest HRCT

Procedia PDF Downloads 59
778 Preparation of Wireless Networks and Security; Challenges in Efficient Accession of Encrypted Data in Healthcare

Authors: M. Zayoud, S. Oueida, S. Ionescu, P. AbiChar

Abstract:

Background: Wireless sensor network is encompassed of diversified tools of information technology, which is widely applied in a range of domains, including military surveillance, weather forecasting, and earthquake forecasting. Strengthened grounds are always developed for wireless sensor networks, which usually emerges security issues during professional application. Thus, essential technological tools are necessary to be assessed for secure aggregation of data. Moreover, such practices have to be incorporated in the healthcare practices that shall be serving in the best of the mutual interest Objective: Aggregation of encrypted data has been assessed through homomorphic stream cipher to assure its effectiveness along with providing the optimum solutions to the field of healthcare. Methods: An experimental design has been incorporated, which utilized newly developed cipher along with CPU-constrained devices. Modular additions have also been employed to evaluate the nature of aggregated data. The processes of homomorphic stream cipher have been highlighted through different sensors and modular additions. Results: Homomorphic stream cipher has been recognized as simple and secure process, which has allowed efficient aggregation of encrypted data. In addition, the application has led its way to the improvisation of the healthcare practices. Statistical values can be easily computed through the aggregation on the basis of selected cipher. Sensed data in accordance with variance, mean, and standard deviation has also been computed through the selected tool. Conclusion: It can be concluded that homomorphic stream cipher can be an ideal tool for appropriate aggregation of data. Alongside, it shall also provide the best solutions to the healthcare sector.

Keywords: aggregation, cipher, homomorphic stream, encryption

Procedia PDF Downloads 254
777 Aeroacoustics Investigations of Unsteady 3D Airfoil for Different Angle Using Computational Fluid Dynamics Software

Authors: Haydar Kepekçi, Baha Zafer, Hasan Rıza Güven

Abstract:

Noise disturbance is one of the major factors considered in the fast development of aircraft technology. This paper reviews the flow field, which is examined on the 2D NACA0015 and 3D NACA0012 blade profile using SST k-ω turbulence model to compute the unsteady flow field. We inserted the time-dependent flow area variables in Ffowcs-Williams and Hawkings (FW-H) equations as an input and Sound Pressure Level (SPL) values will be computed for different angles of attack (AoA) from the microphone which is positioned in the computational domain to investigate effect of augmentation of unsteady 2D and 3D airfoil region noise level. The computed results will be compared with experimental data which are available in the open literature. As results; one of the calculated Cp is slightly lower than the experimental value. This difference could be due to the higher Reynolds number of the experimental data. The ANSYS Fluent software was used in this study. Fluent includes well-validated physical modeling capabilities to deliver fast, accurate results across the widest range of CFD and multiphysics applications. This paper includes a study which is on external flow over an airfoil. The case of 2D NACA0015 has approximately 7 million elements and solves compressible fluid flow with heat transfer using the SST turbulence model. The other case of 3D NACA0012 has approximately 3 million elements.

Keywords: 3D blade profile, noise disturbance, aeroacoustics, Ffowcs-Williams and Hawkings (FW-H) equations, k-ω-SST turbulence model

Procedia PDF Downloads 206
776 Staphylococcus Aureus Septic Arthritis and Necrotizing Fasciitis in a Patient With Undiagnosed Diabetes Mellitus.

Authors: Pedro Batista, André Vinha, Filipe Castelo, Bárbara Costa, Ricardo Sousa, Raquel Ricardo, André Pinto

Abstract:

Background: Septic arthritis is a diagnosis that must be considered in any patient presenting with acute joint swelling and fever. Among the several risk factors for septic arthritis, such as age, rheumatoid arthritis, recent surgery, or skin infection, diabetes mellitus can sometimes be the main risk factor. Staphylococcus aureus is the most common pathogen isolated in septic arthritis; however, it is uncommon in monomicrobial necrotizing fasciitis. Objectives: A case report of concomitant septic arthritis and necrotizing fasciitis in a patient with undiagnosed diabetes based on clinical history. Study Design & Methods: We report a case of a 58-year-old Portuguese previously healthy man who presented to the emergency department with fever and left knee swelling and pain for two days. The blood work revealed ketonemia of 6.7 mmol/L and glycemia of 496 mg/dL. The vital signs were significant for a temperature of 38.5 ºC and 123 bpm of heart rate. The left knee had edema and inflammatory signs. Computed tomography of the left knee showed diffuse edema of the subcutaneous cellular tissue and soft tissue air bubbles. A diagnosis of septic arthritis and necrotising fasciitis was made. He was taken to the operating room for surgical debridement. The samples collected intraoperatively were sent for microbiological analysis, revealing infection by multi-sensitive Staphylococcus aureus. Given this result, the empiric flucloxacillin (500 mg IV) and clindamycin (1000 mg IV) were maintained for 3 weeks. On the seventh day of hospitalization, there was a significant improvement in subcutaneous and musculoskeletal tissues. After two weeks of hospitalization, there was no purulent content and partial closure of the wounds was possible. After 3 weeks, he was switched to oral antibiotics (flucloxacillin 500 mg). A week later, a urinary infection by Pseudomonas aeruginosa was diagnosed and ciprofloxacin 500 mg was administered for 7 days without complications. After 30 days of hospital admission, the patient was discharged home and recovered. Results: The final diagnosis of concomitant septic arthritis and necrotizing fasciitis was made based on the imaging findings, surgical exploration and microbiological tests results. Conclusions: Early antibiotic administration and surgical debridement are key in the management of septic arthritis and necrotizing fasciitis. Furthermore, risk factors control (euglycemic blood glucose levels) must always be taken into account given the crucial role in the patient's recovery.

Keywords: septic arthritis, Necrotizing fasciitis, diabetes, Staphylococcus Aureus

Procedia PDF Downloads 309
775 Personal Characteristics and Personality Traits as Predictors of Compassion Fatigue among Counselors from Dominican Schools in the Philippines

Authors: Neil Jordan M. Uy, Fe Pelilia V. Hernandez

Abstract:

A counselor is always regarded as a professional who embodies the willingness to help others through the process of counseling. He is knowledgeable and skillful of the different theories, tools, and techniques that are useful in aiding the client to cope with their dilemmas. The negative experiences of the clients that are shared during the counseling session can affect the professional counselor. Compassion fatigue, a professional impairment, is characterized by the decline of one’s productivity and the feeling of anxiety and stress brought about as the counselor empathizes, listens, and cares for others. This descriptive type of research aimed to explore variables that are predictors of compassion fatigue utilizing three research instruments; Demographic Profile Sheet, Professional Quality of Life Scale, and Neo-Pi-R. The 52 respondents of this study were counselors from the different Dominican schools in the Philippines. Generally, the counselors have low level of compassion fatigue across personal characteristics (age, gender, years of service, highest educational attainment, and professional status) and personality traits (extraversion, agreeableness, conscientiousness, openness, and neuroticism). ANOVA validated the findings of this that among the personal characteristics and personality traits, extraversion with f-value of 3.944 and p-value of 0.026, and conscientiousness, with f-value of 4.125 and p-value of 0.022 were found to have significant difference in the level of compassion fatigue. A very significant difference was observed with neuroticism with f-value of 6.878 and p-value 0.002. Among the personal characteristics and personal characteristics, only neuroticism was found to predict compassion fatigue. The computed r2 value of 0.204 using multiple regression analysis suggests that 20.4 percent of compassion fatigue can be predicted by neuroticism. The predicting power of neuroticism can be computed from the regression model Y=0.156x+26.464; where x is the number of neuroticism.

Keywords: big five personality traits, compassion fatigue, counselors, professional quality of life scale

Procedia PDF Downloads 373
774 A Case of Prosthetic Vascular-Graft Infection Due to Mycobacterium fortuitum

Authors: Takaaki Nemoto

Abstract:

Case presentation: A 69-year-old Japanese man presented with a low-grade fever and fatigue that had persisted for one month. The patient had an aortic dissection on the aortic arch 13 years prior, an abdominal aortic aneurysm seven years prior, and an aortic dissection on the distal aortic arch one year prior, which were all treated with artificial blood-vessel replacement surgery. Laboratory tests revealed an inflammatory response (CRP 7.61 mg/dl), high serum creatinine (Cr 1.4 mg/dL), and elevated transaminase (AST 47 IU/L, ALT 45 IU/L). The patient was admitted to our hospital on suspicion of prosthetic vascular graft infection. Following further workups on the inflammatory response, an enhanced chest computed tomography (CT) and a non-enhanced chest DWI (MRI) were performed. The patient was diagnosed with a pulmonary fistula and a prosthetic vascular graft infection on the distal aortic arch. After admission, the patient was administered Ceftriaxion and Vancomycine for 10 days, but his fever and inflammatory response did not improve. On day 13 of hospitalization, a lung fistula repair surgery and an omental filling operation were performed, and Meropenem and Vancomycine were administered. The fever and inflammatory response continued, and therefore we took repeated blood cultures. M. fortuitum was detected in a blood culture on day 16 of hospitalization. As a result, we changed the treatment regimen to Amikacin (400 mg/day), Meropenem (2 g/day), and Cefmetazole (4 g/day), and the fever and inflammatory response began to decrease gradually. We performed a test of sensitivity for Mycobacterium fortuitum, and found that the MIC was low for fluoroquinolone antibacterial agent. The clinical course was good, and the patient was discharged after a total of 8 weeks of intravenous drug administration. At discharge, we changed the treatment regimen to Levofloxacin (500 mg/day) and Clarithromycin (800 mg/day), and prescribed these two drugs as a long life suppressive therapy. Discussion: There are few cases of prosthetic vascular graft infection caused by mycobacteria, and a standard therapy remains to be established. For prosthetic vascular graft infections, it is ideal to provide surgical and medical treatment in parallel, but in this case, surgical treatment was difficult and, therefore, a conservative treatment was chosen. We attempted to increase the treatment success rate of this refractory disease by conducting a susceptibility test for mycobacteria and treating with different combinations of antimicrobial agents, which was ultimately effective. With our treatment approach, a good clinical course was obtained and continues at the present stage. Conclusion: Although prosthetic vascular graft infection resulting from mycobacteria is a refractory infectious disease, it may be curative to administer appropriate antibiotics based on the susceptibility test in addition to surgical treatment.

Keywords: prosthetic vascular graft infection, lung fistula, Mycobacterium fortuitum, conservative treatment

Procedia PDF Downloads 149
773 Assessment of E-learning Facilities and Information Need by Open and Distance Learning Students in Jalingo, Nigeria

Authors: R. M. Bashir, Sabo Elizabeth

Abstract:

Electronic learning is an increasingly popular learning approach in higher educational institutions due to vast growth of internet technology. An investigation on the assessment of e-learning facilities and information need by open and distance learning students in Jalingo, Nigeria was conducted. Structured questionnaires were administered to 70 students of the university. Information sourced from the respondents covered demographic, economic and institutional variables. Data collected for demographic variables were computed as frequency count and percentages. Information on assessment of e-learning facilities and information need among open and distance learning students was computed on a three or four point Likert Rating Scale. Findings indicated that there are more men compared to women, a large proportion of the respondents are married and there are more matured students. A high proportion of the students obtained qualifications higher than the secondary school certificate. The proportion of computer literate students was higher compared with those students that owned a computer. Inadequate e-books and reference materials, internet gadgets and inadequate books (hard copies) and reference material are factors that limit utilization of e-learning facilities. Inadequate computer facilities caused delay in examination schedule at the study center. Open and distance learning students required to a high extent information on university timetable and schedule of activities, books (hard and e-books) and reference materials and contact with course coordinators via internet for better learning and academic performance.

Keywords: open and distance learning, information required, electronic books, internet gadgets, Likert scale test

Procedia PDF Downloads 282
772 Implementation of Synthesis and Quality Control Procedures of ¹⁸F-Fluoromisonidazole Radiopharmaceutical

Authors: Natalia C. E. S. Nascimento, Mercia L. Oliveira, Fernando R. A. Lima, Leonardo T. C. do Nascimento, Marina B. Silveira, Brigida G. A. Schirmer, Andrea V. Ferreira, Carlos Malamut, Juliana B. da Silva

Abstract:

Tissue hypoxia is a common characteristic of solid tumors leading to decreased sensitivity to radiotherapy and chemotherapy. In the clinical context, tumor hypoxia assessment employing the positron emission tomography (PET) tracer ¹⁸F-fluoromisonidazole ([¹⁸F]FMISO) is helpful for physicians for planning and therapy adjusting. The aim of this work was to implement the synthesis of 18F-FMISO in a TRACERlab® MXFDG module and also to establish the quality control procedure. [¹⁸F]FMISO was synthesized at Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN/Brazil) using an automated synthesizer (TRACERlab® MXFDG, GE) adapted for the production of [¹⁸F]FMISO. The FMISO chemical standard was purchased from ABX. 18O- enriched water was acquired from Center of Molecular Research. Reagent kits containing eluent solution, acetonitrile, ethanol, 2.0 M HCl solution, buffer solution, water for injections and [¹⁸F]FMISO precursor (dissolved in 2 ml acetonitrile) were purchased from ABX. The [¹⁸F]FMISO samples were purified by Solid Phase Extraction method. The quality requirements of [¹⁸F]FMISO are established in the European Pharmacopeia. According to that reference, quality control of [¹⁸F]FMISO should include appearance, pH, radionuclidic identity and purity, radiochemical identity and purity, chemical purity, residual solvents, bacterial endotoxins, and sterility. The duration of the synthesis process was 53 min, with radiochemical yield of (37.00 ± 0.01) % and the specific activity was more than 70 GBq/µmol. The syntheses were reproducible and showed satisfactory results. In relation to the quality control analysis, the samples were clear and colorless at pH 6.0. The spectrum emission, measured by using a High-Purity Germanium Detector (HPGe), presented a single peak at 511 keV and the half-life, determined by the decay method in an activimeter, was (111.0 ± 0.5) min, indicating no presence of radioactive contaminants, besides the desirable radionuclide (¹⁸F). The samples showed concentration of tetrabutylammonium (TBA) < 50μg/mL, assessed by visual comparison to TBA standard applied in the same thin layer chromatographic plate. Radiochemical purity was determined by high performance liquid chromatography (HPLC) and the results were 100%. Regarding the residual solvents tested, ethanol and acetonitrile presented concentration lower than 10% and 0.04%, respectively. Healthy female mice were injected via lateral tail vein with [¹⁸F]FMISO, microPET imaging studies (15 min) were performed after 2 h post injection (p.i), and the biodistribution was analyzed in five-time points (30, 60, 90, 120 and 180 min) after injection. Subsequently, organs/tissues were assayed for radioactivity with a gamma counter. All parameters of quality control test were in agreement to quality criteria confirming that [¹⁸F]FMISO was suitable for use in non-clinical and clinical trials, following the legal requirements for the production of new radiopharmaceuticals in Brazil.

Keywords: automatic radiosynthesis, hypoxic tumors, pharmacopeia, positron emitters, quality requirements

Procedia PDF Downloads 189
771 Combined Effect of Moving and Open Boundary Conditions in the Simulation of Inland Inundation Due to Far Field Tsunami

Authors: M. Ashaque Meah, Md. Fazlul Karim, M. Shah Noor, Nazmun Nahar Papri, M. Khalid Hossen, M. Ismoen

Abstract:

Tsunami and inundation modelling due to far field tsunami propagation in a limited area is a very challenging numerical task because it involves many aspects such as the formation of various types of waves and the irregularities of coastal boundaries. To compute the effect of far field tsunami and extent of inland inundation due to far field tsunami along the coastal belts of west coast of Malaysia and Southern Thailand, a formulated boundary condition and a moving boundary condition are simultaneously used. In this study, a boundary fitted curvilinear grid system is used in order to incorporate the coastal and island boundaries accurately as the boundaries of the model domain are curvilinear in nature and the bending is high. The tsunami response of the event 26 December 2004 along the west open boundary of the model domain is computed to simulate the effect of far field tsunami. Based on the data of the tsunami source at the west open boundary of the model domain, a boundary condition is formulated and applied to simulate the tsunami response along the coastal and island boundaries. During the simulation process, a moving boundary condition is initiated instead of fixed vertical seaside wall. The extent of inland inundation and tsunami propagation pattern are computed. Some comparisons are carried out to test the validation of the simultaneous use of the two boundary conditions. All simulations show excellent agreement with the data of observation.

Keywords: open boundary condition, moving boundary condition, boundary-fitted curvilinear grids, far-field tsunami, shallow water equations, tsunami source, Indonesian tsunami of 2004

Procedia PDF Downloads 441
770 Calculation of Lungs Physiological Lung Motion in External Lung Irradiation

Authors: Yousif Mohamed Y. Abdallah, Khalid H. Eltom

Abstract:

This is an experimental study deals with measurement of the periodic physiological organ motion during lung external irradiation in order to reduce the exposure of healthy tissue during radiation treatments. The results showed for left lung displacement reading (4.52+1.99 mm) and right lung is (8.21+3.77 mm) which the radiotherapy physician should take suitable countermeasures in case of significant errors. The motion ranged between 2.13 mm and 12.2 mm (low and high). In conclusion, the calculation of tumour mobility can improve the accuracy of target areas definition in patients undergo Sterostatic RT for stage I, II and III lung cancer (NSCLC). Definition of the target volume based on a high resolution CT scan with a margin of 3-5 mm is appropriate.

Keywords: physiological motion, lung, external irradiation, radiation medicine

Procedia PDF Downloads 413
769 Congenital Sublingual Dermoid Cyst with Cutaneous Fistula

Authors: Rafael Ricieri, Rogerio Barros, Francisco Clovis

Abstract:

Objective– The Objective of this is study is to report a rare case of dermoid cyst, with a sublingual location and cutaneous fistula in a 4 year-old child.Methods: This study is a case report. The main study instrument was the medical record and the radiological and intraoperative image bank. Results: Infants with congenital cervical lesions eventually need tomography for diagnostic elucidation, and health services should be structured to perform sedation and thin tomographic sections in order to reduce morbidity.

Keywords: congenital, sublingual dermoid cyst, fistula, pediatric surgery, head and kneck surgery

Procedia PDF Downloads 87
768 Confidence Intervals for Process Capability Indices for Autocorrelated Data

Authors: Jane A. Luke

Abstract:

Persistent pressure passed on to manufacturers from escalating consumer expectations and the ever growing global competitiveness have produced a rapidly increasing interest in the development of various manufacturing strategy models. Academic and industrial circles are taking keen interest in the field of manufacturing strategy. Many manufacturing strategies are currently centered on the traditional concepts of focused manufacturing capabilities such as quality, cost, dependability and innovation. Process capability indices was conducted assuming that the process under study is in statistical control and independent observations are generated over time. However, in practice, it is very common to come across processes which, due to their inherent natures, generate autocorrelated observations. The degree of autocorrelation affects the behavior of patterns on control charts. Even, small levels of autocorrelation between successive observations can have considerable effects on the statistical properties of conventional control charts. When observations are autocorrelated the classical control charts exhibit nonrandom patterns and lack of control. Many authors have considered the effect of autocorrelation on the performance of statistical process control charts. In this paper, the effect of autocorrelation on confidence intervals for different PCIs was included. Stationary Gaussian processes is explained. Effect of autocorrelation on PCIs is described in detail. Confidence intervals for Cp and Cpk are constructed for PCIs when data are both independent and autocorrelated. Confidence intervals for Cp and Cpk are computed. Approximate lower confidence limits for various Cpk are computed assuming AR(1) model for the data. Simulation studies and industrial examples are considered to demonstrate the results.

Keywords: autocorrelation, AR(1) model, Bissell’s approximation, confidence intervals, statistical process control, specification limits, stationary Gaussian processes

Procedia PDF Downloads 380
767 X-Ray Detector Technology Optimization In CT Imaging

Authors: Aziz Ikhlef

Abstract:

Most of multi-slices CT scanners are built with detectors composed of scintillator - photodiodes arrays. The photodiodes arrays are mainly based on front-illuminated technology for detectors under 64 slices and on back-illuminated photodiode for systems of 64 slices or more. The designs based on back-illuminated photodiodes were being investigated for CT machines to overcome the challenge of the higher number of runs and connection required in front-illuminated diodes. In backlit diodes, the electronic noise has already been improved because of the reduction of the load capacitance due to the routing reduction. This translated by a better image quality in low signal application, improving low dose imaging in large patient population. With the fast development of multi-detector-rows CT (MDCT) scanners and the increasing number of examinations, the clinical community has raised significant concerns on radiation dose received by the patient in both medical and regulatory community. In order to reduce individual exposure and in response to the recommendations of the International Commission on Radiological Protection (ICRP) which suggests that all exposures should be kept as low as reasonably achievable (ALARA), every manufacturer is trying to implement strategies and solutions to optimize dose efficiency and image quality based on x-ray emission and scanning parameters. The added demands on the CT detector performance also comes from the increased utilization of spectral CT or dual-energy CT in which projection data of two different tube potentials are collected. One of the approaches utilizes a technology called fast-kVp switching in which the tube voltage is switched between 80kVp and 140kVp in fraction of a millisecond. To reduce the cross-contamination of signals, the scintillator based detector temporal response has to be extremely fast to minimize the residual signal from previous samples. In addition, this paper will present an overview of detector technologies and image chain improvement which have been investigated in the last few years to improve the signal-noise ratio and the dose efficiency CT scanners in regular examinations and in energy discrimination techniques. Several parameters of the image chain in general and in the detector technology contribute in the optimization of the final image quality. We will go through the properties of the post-patient collimation to improve the scatter-to-primary ratio, the scintillator material properties such as light output, afterglow, primary speed, crosstalk to improve the spectral imaging, the photodiode design characteristics and the data acquisition system (DAS) to optimize for crosstalk, noise and temporal/spatial resolution.

Keywords: computed tomography, X-ray detector, medical imaging, image quality, artifacts

Procedia PDF Downloads 261
766 Factor Associated with Uncertainty Undergoing Hematopoietic Stem Cell Transplantation

Authors: Sandra Adarve, Jhon Osorio

Abstract:

Uncertainty has been studied in patients with different types of cancer, except in patients with hematologic cancer and undergoing transplantation. The purpose of this study was to identify factors associated with uncertainty in adults patients with malignant hemato-oncology diseases who are scheduled to undergo hematopoietic stem cell transplantation based on Merle Mishel´s Uncertainty theory. This was a cross-sectional study with an analytical purpose. The study sample included 50 patients with leukemia, myeloma, and lymphoma selected by non-probability sampling by convenience and intention. Sociodemographic and clinical variables were measured. Mishel´s Scale of Uncertainty in Illness was used for the measurement of uncertainty. A bivariate and multivariate analyses were performed to explore the relationships and associations between the different variables and uncertainty level. For this analysis, the distribution of the uncertainty scale values was evaluated through the Shapiro-Wilk normality test to identify statistical tests to be used. A multivariate analysis was conducted through a logistic regression using step-by-step technique. Patients were 18-74 years old, with a mean age of 44.8. Over time, the disease course had a median of 9.5 months, an opportunity was found in the performance of the transplantation of < 20 days for 50% of the patients. Regarding the uncertainty scale, a mean score of 95.46 was identified. When the dimensions of the scale were analyzed, the mean score of the framework of stimuli was 25.6, of cognitive ability was 47.4 and structure providers was 22.8. Age was identified to correlate with the total uncertainty score (p=0.012). Additionally, a statistically significant difference was evidenced between different religious creeds and uncertainty score (p=0.023), education level (p=0.012), family history of cancer (p=0.001), the presence of comorbidities (p=0.023) and previous radiotherapy treatment (p=0.022). After performing logistic regression, previous radiotherapy treatment (OR=0.04 IC95% (0.004-0.48)) and family history of cancer (OR=30.7 IC95% (2.7-349)) were found to be factors associated with the high level of uncertainty. Uncertainty is present in high levels in patients who are going to be subjected to bone marrow transplantation, and it is the responsibility of the nurse to assess the levels of uncertainty and the presence of factors that may contribute to their presence. Once it has been valued, the uncertainty must be intervened from the identified associated factors, especially all those that have to do with the cognitive capacity. This implies the implementation and design of intervention strategies to improve the knowledge related to the disease and the therapeutic procedures to which the patients will be subjected. All interventions should favor the adaptation of these patients to their current experience and contribute to seeing uncertainty as an opportunity for growth and transcendence.

Keywords: hematopoietic stem cell transplantation, hematologic diseases, nursing, uncertainty

Procedia PDF Downloads 160
765 A Seven Year Single-Centre Study of Dental Implant Survival in Head and Neck Oncology Patients

Authors: Sidra Suleman, Maliha Suleman, Stephen Brindley

Abstract:

Oral rehabilitation of head and neck cancer patients plays a crucial role in the quality of life for such individuals post-treatment. Placement of dental implants or implant-retained prostheses can help restore oral function and aesthetics, which is often compromised following surgery. Conventional prosthodontic techniques can be insufficient in rehabilitating such patients due to their altered anatomy and reduced oral competence. Hence, there is a strong clinical need for the placement of dental implants. With an increasing incidence of head and neck cancer patients, the demand for such treatment is rising. Aim: The aim of the study was to determine the survival rate of dental implants in head and neck cancer patients placed at the Restorative and Maxillofacial Department, Royal Stoke University Hospital (RSUH), United Kingdom. Methodology: All patients who received dental implants between January 1, 2013 to December 31, 2020 were identified. Patients were excluded based on three criteria: 1) non-head and neck cancer patients, 2) no outpatient follow-up post-implant placement 3) provision of non-dental implants. Scanned paper notes and electronic records were extracted and analyzed. Implant survival was defined as fixtures that had remained in-situ / not required removal. Sample: Overall, 61 individuals were recruited from the 143 patients identified. The mean age was 64.9 years, with a range of 35 – 89 years. The sample included 37 (60.7%) males and 24 (39.3%) females. In total, 211 implants were placed, of which 40 (19.0%) were in the maxilla, 152 (72.0%) in the mandible and 19 (9.0%) in autogenous bone graft sites. Histologically 57 (93.4%) patients had squamous cell carcinoma, with 43 (70.5%) patients having either stage IVA or IVB disease. As part of treatment, 42 (68.9%) patients received radiotherapy, which was carried out post-operatively for 29 (69.0%) cases. Whereas 21 (34.4%) patients underwent chemotherapy, 13 (61.9%) of which were post-operative. The Median follow-up period was 21.9 months with a range from 0.9 – 91.4 months. During the study, 23 (37.7%) patients died and their data was censored beyond the date of death. Results: In total, four patients who had received radiotherapy had one implant failure each. Two mandibular implants failed secondary to osteoradionecrosis, and two maxillary implants did not survive as a result of failure to osseointegrate. The overall implant survival rates were 99.1% at three years and 98.1% at both 5 and 7 years. Conclusions: Although this data shows that implant failure rates are low, it highlights the difficulty in predicting which patients will be affected. Future studies involving larger cohorts are warranted to further analyze factors affecting outcomes.

Keywords: oncology, dental implants, survival, restorative

Procedia PDF Downloads 229
764 Hypersensitivity Reactions Following Intravenous Administration of Contrast Medium

Authors: Joanna Cydejko, Paulina Mika

Abstract:

Hypersensitivity reactions are side effects of medications that resemble an allergic reaction. Anaphylaxis is a generalized, severe allergic reaction of the body caused by exposure to a specific agent at a dose tolerated by a healthy body. The most common causes of anaphylaxis are food (about 70%), Hymenoptera venoms (22%), and medications (7%), despite detailed diagnostics in 1% of people, the cause of the anaphylactic reaction was not indicated. Contrast media are anaphylactic agents of unknown mechanism. Hypersensitivity reactions can occur with both immunological and non-immunological mechanisms. Symptoms of anaphylaxis occur within a few seconds to several minutes after exposure to the allergen. Contrast agents are chemical compounds that make it possible to visualize or improve the visibility of anatomical structures. In the diagnosis of computed tomography, the preparations currently used are derivatives of the triiodide benzene ring. Pharmacokinetic and pharmacodynamic properties, i.e., their osmolality, viscosity, low chemotoxicity and high hydrophilicity, have an impact on better tolerance of the substance by the patient's body. In MRI diagnostics, macrocyclic gadolinium contrast agents are administered during examinations. The aim of this study is to present the results of the number and severity of anaphylactic reactions that occurred in patients in all age groups undergoing diagnostic imaging with intravenous administration of contrast agents. In non-ionic iodine CT and in macrocyclic gadolinium MRI. A retrospective assessment of the number of adverse reactions after contrast administration was carried out on the basis of data from the Department of Radiology of the University Clinical Center in Gdańsk, and it was assessed whether their different physicochemical properties had an impact on the incidence of acute complications. Adverse reactions are divided according to the severity of the patient's condition and the diagnostic method used in a given patient. Complications following the administration of a contrast medium in the form of acute anaphylaxis accounted for less than 0.5% of all diagnostic procedures performed with the use of a contrast agent. In the analysis period from January to December 2022, 34,053 CT scans and 15,279 MRI examinations with the use of contrast medium were performed. The total number of acute complications was 21, of which 17 were complications of iodine-based contrast agents and 5 of gadolinium preparations. The introduction of state-of-the-art contrast formulations was an important step toward improving the safety and tolerability of contrast agents used in imaging. Currently, contrast agents administered to patients are considered to be one of the best-tolerated preparations used in medicine. However, like any drug, they can be responsible for the occurrence of adverse reactions resulting from their toxic effects. The increase in the number of imaging tests performed with the use of contrast agents has a direct impact on the number of adverse events associated with their administration. However, despite the low risk of anaphylaxis, this risk should not be marginalized. The growing threat associated with the mass performance of radiological procedures with the use of contrast agents forces the knowledge of the rules of conduct in the event of symptoms of hypersensitivity to these preparations.

Keywords: anaphylactic, contrast medium, diagnostic, medical imagine

Procedia PDF Downloads 56
763 Optimized Electron Diffraction Detection and Data Acquisition in Diffraction Tomography: A Complete Solution by Gatan

Authors: Saleh Gorji, Sahil Gulati, Ana Pakzad

Abstract:

Continuous electron diffraction tomography, also known as microcrystal electron diffraction (MicroED) or three-dimensional electron diffraction (3DED), is a powerful technique, which in combination with cryo-electron microscopy (cryo-ED), can provide atomic-scale 3D information about the crystal structure and composition of different classes of crystalline materials such as proteins, peptides, and small molecules. Unlike the well-established X-ray crystallography method, 3DED does not require large single crystals and can collect accurate electron diffraction data from crystals as small as 50 – 100 nm. This is a critical advantage as growing larger crystals, as required by X-ray crystallography methods, is often very difficult, time-consuming, and expensive. In most cases, specimens studied via 3DED method are electron beam sensitive, which means there is a limitation on the maximum amount of electron dose one can use to collect the required data for a high-resolution structure determination. Therefore, collecting data using a conventional scintillator-based fiber coupled camera brings additional challenges. This is because of the inherent noise introduced during the electron-to-photon conversion in the scintillator and transfer of light via the fibers to the sensor, which results in a poor signal-to-noise ratio and requires a relatively higher and commonly specimen-damaging electron dose rates, especially for protein crystals. As in other cryo-EM techniques, damage to the specimen can be mitigated if a direct detection camera is used which provides a high signal-to-noise ratio at low electron doses. In this work, we have used two classes of such detectors from Gatan, namely the K3® camera (a monolithic active pixel sensor) and Stela™ (that utilizes DECTRIS hybrid-pixel technology), to address this problem. The K3 is an electron counting detector optimized for low-dose applications (like structural biology cryo-EM), and Stela is also a counting electron detector but optimized for diffraction applications with high speed and high dynamic range. Lastly, data collection workflows, including crystal screening, microscope optics setup (for imaging and diffraction), stage height adjustment at each crystal position, and tomogram acquisition, can be one of the other challenges of the 3DED technique. Traditionally this has been all done manually or in a partly automated fashion using open-source software and scripting, requiring long hours on the microscope (extra cost) and extensive user interaction with the system. We have recently introduced Latitude® D in DigitalMicrograph® software, which is compatible with all pre- and post-energy-filter Gatan cameras and enables 3DED data acquisition in an automated and optimized fashion. Higher quality 3DED data enables structure determination with higher confidence, while automated workflows allow these to be completed considerably faster than before. Using multiple examples, this work will demonstrate how to direct detection electron counting cameras enhance 3DED results (3 to better than 1 Angstrom) for protein and small molecule structure determination. We will also show how Latitude D software facilitates collecting such data in an integrated and fully automated user interface.

Keywords: continuous electron diffraction tomography, direct detection, diffraction, Latitude D, Digitalmicrograph, proteins, small molecules

Procedia PDF Downloads 100
762 Sea Level Characteristics Referenced to Specific Geodetic Datum in Alexandria, Egypt

Authors: Ahmed M. Khedr, Saad M. Abdelrahman, Kareem M. Tonbol

Abstract:

Two geo-referenced sea level datasets (September 2008 – November 2010) and (April 2012 – January 2014) were recorded at Alexandria Western Harbour (AWH). Accurate re-definition of tidal datum, referred to the latest International Terrestrial Reference Frame (ITRF-2014), was discussed and updated to improve our understanding of the old predefined tidal datum at Alexandria. Tidal and non-tidal components of sea level were separated with the use of Delft-3D hydrodynamic model-tide suit (Delft-3D, 2015). Tidal characteristics at AWH were investigated and harmonic analysis showed the most significant 34 constituents with their amplitudes and phases. Tide was identified as semi-diurnal pattern as indicated by a “Form Factor” of 0.24 and 0.25, respectively. Principle tidal datums related to major tidal phenomena were recalculated referred to a meaningful geodetic height datum. The portion of residual energy (surge) out of the total sea level energy was computed for each dataset and found 77% and 72%, respectively. Power spectral density (PSD) showed accurate resolvability in high band (1–6) cycle/days for the nominated independent constituents, except some neighbouring constituents, which are too close in frequency. Wind and atmospheric pressure data, during the recorded sea level time, were analysed and cross-correlated with the surge signals. Moderate association between surge and wind and atmospheric pressure data were obtained. In addition, long-term sea level rise trend at AWH was computed and showed good agreement with earlier estimated rates.

Keywords: Alexandria, Delft-3D, Egypt, geodetic reference, harmonic analysis, sea level

Procedia PDF Downloads 162
761 Integrating Natural Language Processing (NLP) and Machine Learning in Lung Cancer Diagnosis

Authors: Mehrnaz Mostafavi

Abstract:

The assessment and categorization of incidental lung nodules present a considerable challenge in healthcare, often necessitating resource-intensive multiple computed tomography (CT) scans for growth confirmation. This research addresses this issue by introducing a distinct computational approach leveraging radiomics and deep-learning methods. However, understanding local services is essential before implementing these advancements. With diverse tracking methods in place, there is a need for efficient and accurate identification approaches, especially in the context of managing lung nodules alongside pre-existing cancer scenarios. This study explores the integration of text-based algorithms in medical data curation, indicating their efficacy in conjunction with machine learning and deep-learning models for identifying lung nodules. Combining medical images with text data has demonstrated superior data retrieval compared to using each modality independently. While deep learning and text analysis show potential in detecting previously missed nodules, challenges persist, such as increased false positives. The presented research introduces a Structured-Query-Language (SQL) algorithm designed for identifying pulmonary nodules in a tertiary cancer center, externally validated at another hospital. Leveraging natural language processing (NLP) and machine learning, the algorithm categorizes lung nodule reports based on sentence features, aiming to facilitate research and assess clinical pathways. The hypothesis posits that the algorithm can accurately identify lung nodule CT scans and predict concerning nodule features using machine-learning classifiers. Through a retrospective observational study spanning a decade, CT scan reports were collected, and an algorithm was developed to extract and classify data. Results underscore the complexity of lung nodule cohorts in cancer centers, emphasizing the importance of careful evaluation before assuming a metastatic origin. The SQL and NLP algorithms demonstrated high accuracy in identifying lung nodule sentences, indicating potential for local service evaluation and research dataset creation. Machine-learning models exhibited strong accuracy in predicting concerning changes in lung nodule scan reports. While limitations include variability in disease group attribution, the potential for correlation rather than causality in clinical findings, and the need for further external validation, the algorithm's accuracy and potential to support clinical decision-making and healthcare automation represent a significant stride in lung nodule management and research.

Keywords: lung cancer diagnosis, structured-query-language (SQL), natural language processing (NLP), machine learning, CT scans

Procedia PDF Downloads 83
760 Assessment of E-Learning Facilities in Open and Distance Learning and Information Need by Students

Authors: Sabo Elizabeth

Abstract:

Electronic learning is increasingly popular learning approach in higher educational institutions due to vast growth of internet technology. This approach is important in human capital development. An investigation of open distance and e-learning facilities and information need by open and distance learning students was carried out in Jalingo, Nigeria. Structured questionnaires were administered to 70 registered ODL students of the NOUN. Information sourced from the respondents covered demographic, economic and institutional variables. Data collected for demographic variables were computed as frequency count and percentages. Assessment of the effectiveness of ODL facilities and information need among open and distance learning students was computed on a three or four point Likert Rating Scale. Findings indicated that there are more men compared to women. A large proportion of the respondents are married and there are more matured students in ODL compared to the youth. A high proportion of the ODL students obtained qualifications higher than the secondary school certificate. The proportion of computer literate ODL students was high, and large number of the students does not own a laptop computer. Inadequate e -books and reference materials, internet gadgets and inadequate books (hard copies) and reference material are factors that limit utilization of e-learning facilities in the study areas. Inadequate computer facilities and power back up caused inconveniences and delay in administering and use of e learning facilities. To a high extent, open and distance learning students needed information on university time table and schedule of activities, availability and access to books (hard and e-books) and reference materials. The respondents emphasized that contact with course coordinators via internet will provide a better learning and academic performance.

Keywords: open and distance learning, information required, electronic books, internet gadgets, Likert scale test

Procedia PDF Downloads 320
759 The Use of the Matlab Software as the Best Way to Recognize Penumbra Region in Radiotherapy

Authors: Alireza Shayegan, Morteza Amirabadi

Abstract:

The y tool was developed to quantitatively compare dose distributions, either measured or calculated. Before computing ɣ, the dose and distance scales of the two distributions, referred to as evaluated and reference, are re-normalized by dose and distance criteria, respectively. The re-normalization allows the dose distribution comparison to be conducted simultaneously along dose and distance axes. Several two-dimensional images were acquired using a Scanning Liquid Ionization Chamber EPID and Extended Dose Range (EDR2) films for regular and irregular radiation fields. The raw images were then converted into two-dimensional dose maps. Transitional and rotational manipulations were performed for images using Matlab software. As evaluated dose distribution maps, they were then compared with the corresponding original dose maps as the reference dose maps.

Keywords: energetic electron, gamma function, penumbra, Matlab software

Procedia PDF Downloads 292