Search results for: emergency power assist system
22619 The Batteryless Wi-Fi Backscatter System and Method for Improving the Transmission Range
Authors: Young-Min Ko, Seung-Jun Yu, Seongjoo Lee, Hyoung-Kyu Song
Abstract:
The Internet of things (IoT) system has attracted attention. IoT is a technology to connect all the objects to the internet as well as computer. IoT makes it possible for providing more data interoperability methods for an application purpose. Among the IoT technology, the research of devices so that they can communicate without power supply has been actively conducted. Batteryless system permits us to communicate without power supply devices. In this paper, batteryless backscatter system is used as a tag. And mobile devices which are embedded wireless fidelity (Wi-Fi) chipset are used as a reader. The backscatter tag can be obtained Internet connectivity from the reader. Conventional Wi-Fi backscatter system has limitation in the transmission range. In this paper, the proposed algorithm can be obtained improved reliability as well as overcoming the limitation about transmission range.Keywords: Ambient RF, Backscatter, Batteryless communication, Energy-harvesting, IoT, RFID, Tag, Wi-Fi
Procedia PDF Downloads 38922618 Development of a Single Drive for the Accessories Components in IC Engine
Authors: R. Rishi Jain, S. V. Viswanath, R. Naveen Vasanthan
Abstract:
Generally all the IC engines, alternators, air conditioner compressors, oil pumps and coolant pumps are driven by a crankshaft utilizing V-belt drivers. An increase in the number of idle pulleys results in the increase of frictional power. Further, components like idler and belt tensioner are also needed to run the belt drive which adds to the frictional power. The aspiration of this paper is to minimize the friction power by introducing a new system that could combine all the accessories in one shaft within a single casing. This is conceptualized to minimize the friction power, service and maintenance cost, space and also time. The validation of this work can be executed through a simpler drive transmitting power from the crank shaft.Keywords: single drive, idler pulley, belt tensioner, friction power, casing, space and cost
Procedia PDF Downloads 31822617 Simulation of Wind Solar Hybrid Power Generation for Pumping Station
Authors: Masoud Taghavi, Gholamreza Salehi, Ali Lohrasbi Nichkoohi
Abstract:
Despite the growing use of renewable energies in different fields of application of this technology in the field of water supply has been less attention. Photovoltaic and wind hybrid system is that new topics in renewable energy, including photovoltaic arrays, wind turbines, a set of batteries as a storage system and a diesel generator as a backup system is. In this investigation, first climate data including average wind speed and solar radiation at any time during the year, data collection and analysis are performed in the energy. The wind turbines in four models, photovoltaic panels at the 6 position of relative power, batteries and diesel generator capacity in seven states in the two models are combined hours of operation with renewables, diesel generator and battery bank check and a hybrid system of solar power generation-wind, which is optimized conditions, are presented.Keywords: renewable energy, wind and solar energy, hybrid systems, cloning station
Procedia PDF Downloads 39922616 Power Series Solution to Sliding Velocity in Three-Dimensional Multibody Systems with Impact and Friction
Authors: Hesham A. Elkaranshawy, Amr M. Abdelrazek, Hosam M. Ezzat
Abstract:
The system of ordinary nonlinear differential equations describing sliding velocity during impact with friction for a three-dimensional rigid-multibody system is developed. No analytical solutions have been obtained before for this highly nonlinear system. Hence, a power series solution is proposed. Since the validity of this solution is limited to its convergence zone, a suitable time step is chosen and at the end of it a new series solution is constructed. For a case study, the trajectory of the sliding velocity using the proposed method is built using 6 time steps, which coincides with a Runge-Kutta solution using 38 time steps.Keywords: impact with friction, nonlinear ordinary differential equations, power series solutions, rough collision
Procedia PDF Downloads 48822615 Design of 900 MHz High Gain SiGe Power Amplifier with Linearity Improved Bias Circuit
Authors: Guiheng Zhang, Wei Zhang, Jun Fu, Yudong Wang
Abstract:
A 900 MHz three-stage SiGe power amplifier (PA) with high power gain is presented in this paper. Volterra Series is applied to analyze nonlinearity sources of SiGe HBT device model clearly. Meanwhile, the influence of operating current to IMD3 is discussed. Then a β-helper current mirror bias circuit is applied to improve linearity, since the β-helper current mirror bias circuit can offer stable base biasing voltage. Meanwhile, it can also work as predistortion circuit when biasing voltages of three bias circuits are fine-tuned, by this way, the power gain and operating current of PA are optimized for best linearity. The three power stages which fabricated by 0.18 μm SiGe technology are bonded to the printed circuit board (PCB) to obtain impedances by Load-Pull system, then matching networks are done for best linearity with discrete passive components on PCB. The final measured three-stage PA exhibits 21.1 dBm of output power at 1 dB compression point (OP1dB) with power added efficiency (PAE) of 20.6% and 33 dB power gain under 3.3 V power supply voltage.Keywords: high gain power amplifier, linearization bias circuit, SiGe HBT model, Volterra series
Procedia PDF Downloads 33922614 Power Control of DFIG in WECS Using Backstipping and Sliding Mode Controller
Authors: Abdellah Boualouch, Ahmed Essadki, Tamou Nasser, Ali Boukhriss, Abdellatif Frigui
Abstract:
This paper presents a power control for a Doubly Fed Induction Generator (DFIG) using in Wind Energy Conversion System (WECS) connected to the grid. The proposed control strategy employs two nonlinear controllers, Backstipping (BSC) and sliding-mode controller (SMC) scheme to directly calculate the required rotor control voltage so as to eliminate the instantaneous errors of active and reactive powers. In this paper the advantages of BSC and SMC are presented, the performance and robustness of this two controller’s strategy are compared between them. First, we present a model of wind turbine and DFIG machine, then a synthesis of the controllers and their application in the DFIG power control. Simulation results on a 1.5MW grid-connected DFIG system are provided by MATLAB/Simulink.Keywords: backstipping, DFIG, power control, sliding-mode, WESC
Procedia PDF Downloads 59322613 Coordinated Voltage Control in Radial Distribution System with Distributed Generators Using Sensitivity Analysis
Authors: Anubhav Shrivastava Shivarudraswamy, Bhat Lakshya
Abstract:
Distributed generation has indeed become a major area of interest in recent years. Distributed generation can address a large number of loads in a power line and hence has better efficiency over the conventional methods. However, there are certain drawbacks associated with it, an increase in voltage being the major one. This paper addresses the voltage control at the buses for an IEEE 30 bus system by regulating reactive power. For carrying out the analysis, the suitable location for placing distributed generators (DG) is identified through load flow analysis and seeing where the voltage profile is dipping. MATLAB programming is used to regulate the voltage at all buses within +/- 5% of the base value even after the introduction of DGs. Three methods for regulation of voltage are discussed. A sensitivity based analysis is then carried out to determine the priority among the various methods listed in the paper.Keywords: distributed generators, distributed system, reactive power, voltage control, sensitivity analysis
Procedia PDF Downloads 65722612 Roadway Maintenance Management System
Authors: Chika Catherine Ayogu
Abstract:
Rehabilitation plays an important and integral part in the life of roadway rehabilitation management system. It is a systematic method for inspection and rating the roadway condition in a given area. The system performs a cost effective analysis of various maintenance and rehabilitation strategies. Finally the system prioritize and recommend roadway rehabilitation and maintenance to maximize results within a given budget amount. During execution of maintenance activity, the system also tracks labour, materials, equipment and cost for activities performed. The system implements physical assessment field inspection and rating of each street segment which is then entered into a database. The information is analyzed using a software, and provide recommendations and project future conditions. The roadway management system provides a deterioration curve for each segment based on input then assigns the most cost-effective maintenance strategy based on conditions, surface type and functional classification, and available budget. This paper investigates the roadway management system and its capabilities to assist in applying the right treatment to the right roadway at the right time so that expected service life of the roadway is extended as long as possible with acceptable cost.Keywords: effectiveness, rehabilitation, roadway, software system
Procedia PDF Downloads 15022611 ‘Call Before, Save Lives’: Reducing Emergency Department Visits through Effective Communication
Authors: Sandra Cardoso, Gaspar Pais, Judite Neves, Sandra Cavaca, Fernando Araújo
Abstract:
In 2021, Portugal has 63 emergency department (ED) visits per 100 people annually, the highest numbers in Europe. While EDs provide a critical service, high use is indicative of inappropriate and inefficient healthcare. In Portugal, all ED have the Manchester Triage System (MTS), a clinical risk management tool to enable that patients are seen in order of clinical priority. In 2023, more than 40% of the ED visits were of non-urgent conditions (blue and green), that could be better managed in primary health care (PHC), meaning wrong use of resources and lack of health literacy. From 2017, the country has a phone line, SNS24 (Contact Centre of the National Health Service), for triage, counseling, and referral service, 24 hours/7 days a week. The pilot project ‘Call before, save lives’ was implemented in the municipalities of Póvoa de Varzim and Vila do Conde (around 150.000 residents), in May 2023, by the executive board of the Portuguese Health Service, with the support of the Shared Services of the Ministry of Health, and local authorities. This geographical area has short travel times, 99% of the population a family doctor and the region is organized in a health local unit (HLU), integrating PHC and the local hospital. The purposes of this project included to increase awareness to contact SNS 24, before going to an ED, and non-urgent conditions oriented to a family doctor, reducing ED visits. The implementation of the project involved two phases, beginning with: i) development of campaigns using local influencers (fishmonger, model, fireman) through local institutions and media; ii) provision of telephone installed on site to contact SNS24; iii) establishment of open consultation in PHC; iv) promotion of the use of SNS24; v) creation of acute consultations at the hospital for complex chronic patients; and vi) direct referral for home hospitalization by PHC. The results of this project showed an excellent level of access to SNS24, an increase in the number of users referred to ED, with great satisfaction of users and professionals. The second phase, initiated in January 2024, for access to the ED, the need for prior referral was established as an admission rule, except for certain situations, as trauma patients. If the patient refuses, their registration in the ED and subsequent screening in accordance with the MTS must be ensured. When the patient is non-urgent, shall not be observed in the ED, provided that, according to his clinical condition, is guaranteed to be referred to PHC or to consultation/day hospital, through effective scheduling of an appointment for the same or the following day. In terms of results, 8 weeks after beginning of phase 2, we assist of a decrease in self-reported patients to ED from 59% to 15%, and a reduction of around 7% of ED visits. The key for this success was an effective public campaign that increases the knowledge of the right use of the health system, and capable of changing behaviors.Keywords: contact centre of the national health service, emergency department visits, public campaign, health literacy, SNS24
Procedia PDF Downloads 6722610 Sustainability through Resilience: How Emergency Responders Cope with Stressors
Authors: Sophie Kroeling, Agnetha Schuchardt
Abstract:
Striving for sustainability brings a lot of challenges for different fields of interest, e. g. security or health concerns. In Germany, civil protection is predominantly carried out by emergency responders who perform essential tasks of civil protection. Based on theoretical concepts of different psychological stress theories this contribution focuses on the question, how the resilience of emergency responders can be improved. The goal is to identify resources and successful coping strategies that help to prevent and reduce negative outcomes during or after stressful events. The paper will present results from a qualitative analysis of semi-structured qualitative interviews with 20 emergency responders. These results provide insights into the complexity of coping processes (e. g. controlling the situation, downplaying perceived personal threats through humor) and show the diversity of stressors (like complexity of the disastrous situation, intrusive press and media, or lack of social support within the organization). Self-efficacy expectation was a very important resource for coping with stressful situations. The results served as a starting point for a quantitative survey (that was conducted in March 2017), the development of education and training tools for emergency responders and the improvement of critical incident stress management processes. First results from the quantitative study with more than 700 participants show that, e. g., the emergency responders use social coping within their private social network and also within their aid organization and that both are correlated to resilience. Moreover, missing information, bureaucratic problems and social conflicts within the organization are events that the majority of the participants considered very onerous. Further results from regression analysis will be presented. The proposed paper will combine findings from the qualitative study with the quantitative results, illustrating figures and correlations with respective statements from the interviews. At the end, suggestions for the improvement of the emergency responder’s resilience are given and it is discussed how this can make a contribution to strive for civil security and furthermore a sustainable development.Keywords: civil security, emergency responders, stress, resilience, resources
Procedia PDF Downloads 14422609 The Potentials of Online Learning and the Challenges towards Its Adoption in Nigeria's Higher Institutions of Learning
Authors: Kuliya Muhammed
Abstract:
This paper examines the potentials of online learning and the challenges to its adoption in Nigeria’s higher institutions of learning. The research would assist in tackling the challenges of online learning adoption and enlighten institutions on the numerous benefits of online learning in Nigeria. The researcher used survey method for the study and questionnaires were used to obtain the needed data from 230 respondents cut across 20 higher institutions in the country. The findings revealed that online learning has the prospect to boost access to learning tools, assist students’ to learn from the comfort of their offices or homes, reduce the cost of learning, and enable individuals to gain self-knowledge. The major challenges in the adoption of e-learning are poor Information and Communication Technology infrastructures, poor internet connectivity where available, lack of Information and Communication Technology background, problem of power supply, lack of commitment by institutions, poor maintenance of Information and Communication Technology tools, inadequate facilities, lack of government funding and fraud. Recommendations were also made at the end of the research work.Keywords: electronic, ICT, institution, internet, learning, technology
Procedia PDF Downloads 38822608 Development of a Flexible Lora-Based Wireless Sensory System for Long-Time Health Monitoring of Civil Structures
Authors: Hui Zhang, Sherif Beskhyroun
Abstract:
In this study, a highly flexible LoRa-Based wireless sensing system was used to assess the strain state performance of building structures. The system was developed to address the local damage limitation of structural health monitoring (SHM) systems. The system is part of an intelligent SHM system designed to monitor, collect and transmit strain changes in key structural components. The main purpose of the wireless sensor system is to reduce the development and installation costs, and reduce the power consumption of the system, so as to achieve long-time monitoring. The highly stretchable flexible strain gauge is mounted on the surface of the structure and is waterproof, heat resistant, and low temperature resistant, greatly reducing the installation and maintenance costs of the sensor. The system was also developed with the aim of using LoRa wireless communication technology to achieve both low power consumption and long-distance transmission, therefore solving the problem of large-scale deployment of sensors to cover more areas in large structures. In the long-term monitoring of the building structure, the system shows very high performance, very low actual power consumption, and wireless transmission stability. The results show that the developed system has a high resolution, sensitivity, and high possibility of long-term monitoring.Keywords: LoRa, SHM system, strain measurement, civil structures, flexible sensing system
Procedia PDF Downloads 10322607 Analysis of Electromechanical Torsional Vibration in Large-Power AC Drive System Based on Virtual Inertia Control
Authors: Jin Wang, Chunyi Zhu, Chongjian Li, Dapeng Zheng
Abstract:
A method based on virtual inertia for suppressing electromechanical torsional vibration of a large-power AC drive system is presented in this paper. The main drive system of the rolling mill is the research object, and a two-inertia elastic model is established to study the mechanism of electromechanical torsional vibration. The improvement is made based on the control of the load observer. The virtual inertia control ratio K is added to the speed forward channel, and the feedback loop adds 1-K to design virtual inertia control. The control method combines the advantages of the positive and negative feedback control of the load observer, can achieve the purpose of controlling the moment of inertia of the motor from the perspective of electrical control, and effectively suppress oscillation.Keywords: electromechanical torsional vibration, large-power AC drive system, load observer, simulation design
Procedia PDF Downloads 12522606 Electromechanical-Traffic Model of Compression-Based Piezoelectric Energy Harvesting System
Authors: Saleh Gareh, B. C. Kok, H. H. Goh
Abstract:
Piezoelectric energy harvesting has advantages over other alternative sources due to its large power density, ease of applications, and capability to be fabricated at different scales: macro, micro, and nano. This paper presents an electromechanical-traffic model for roadway compression-based piezoelectric energy harvesting system. A two-degree-of-freedom (2-DOF) electromechanical model has been developed for the piezoelectric energy harvesting unit to define its performance in power generation under a number of external excitations on road surface. Lead Zirconate Titanate (PZT-5H) is selected as the piezoelectric material to be used in this paper due to its high Piezoelectric Charge Constant (d) and Piezoelectric Voltage Constant (g) values. The main source of vibration energy that has been considered in this paper is the moving vehicle on the road. The effect of various frequencies on possible generated power caused by different vibration characteristics of moving vehicle has been studied. A single unit of circle-shape Piezoelectric Cymbal Transducer (PCT) with diameter of 32 mm and thickness of 0.3 mm be able to generate about 0.8 mW and 3 mW of electric power under 4 Hz and 20 Hz of excitation, respectively. The estimated power to be generated for multiple arrays of PCT is approximately 150 kW/ km. Thus, the developed electromechanical-traffic model has enormous potential to be used in estimating the macro scale of roadway power generation system.Keywords: piezoelectric energy harvesting, cymbal transducer, PZT (lead zirconate titanate), 2-DOF
Procedia PDF Downloads 35522605 Collaborative Early Warning System: An Integrated Framework for Mitigating Impacts of Natural Hazards in the UAE
Authors: Abdulla Al Hmoudi
Abstract:
The impacts and costs of natural disasters on people, properties and the environment is often severe when they occur on a large scale or when not prepared for. Factors such as impacts of climate change, urban growth, poor planning to mention a few, have continued to significantly increase the frequencies and aggravate the impacts of natural hazards across the world; the United Arab Emirates (UAE) inclusive. The lack of deployment of an early warning system, low risk and hazard knowledge and impact of natural hazard experienced in some communities in the UAE have emphasised the need for more effective early warning systems. This paper focuses on the collaborative approach taken to instituting and implementing an early warning system. Using mixed methods 888 people completed the questionnaire and eight people were interviewed in Abu Dhabi. The results indicate that the collaborative approach to early warning system is UAE is needed, but lacks essential principles of the early warning system and currently underutilised. It is recommended that the collaborative early warning system is applied at every stage of the early warning system with the specific responsibility of each stakeholder and actor.Keywords: community, early warning system, emergency management, UAE
Procedia PDF Downloads 14422604 Performance Analysis of a Shell and Tube Heat Exchanger in the Organic Rankine Cycle Power Plant
Authors: Yogi Sirodz Gaos, Irvan Wiradinata
Abstract:
In the 500 kW Organic Rankine Cycle (ORC) power plant in Indonesia, an AFT (according to the Tubular Exchanger Manufacturers Association – TEMA) type shell and tube heat exchanger device is used as a pre-heating system for the ORC’s hot water circulation system. The pre-heating source is a waste heat recovery of the brine water, which is tapped from a geothermal power plant. The brine water itself has 5 MWₜₕ capacities, with average temperature of 170ᵒC, and 7 barg working pressure. The aim of this research is to examine the performance of the heat exchanger in the ORC system in a 500 kW ORC power plant. The data for this research were collected during the commissioning on the middle of December 2016. During the commissioning, the inlet temperature and working pressure of the brine water to the shell and tube type heat exchanger was 149ᵒC, and 4.4 barg respectively. Furthermore, the ΔT for the hot water circulation of the ORC system to the heat exchanger was 27ᵒC, with the inlet temperature of 140ᵒC. The pressure in the hot circulation system was dropped slightly from 7.4ᵒC to 7.1ᵒC. The flow rate of the hot water circulation was 80.5 m³/h. The presentation and discussion of a case study on the performance of the heat exchanger on the 500 kW ORC system is presented as follows: (1) the heat exchange duty is 2,572 kW; (2) log mean temperature of the heat exchanger is 13.2ᵒC; (3) the actual overall thermal conductivity is 1,020.6 W/m².K (4) the required overall thermal conductivity is 316.76 W/m².K; and (5) the over design for this heat exchange performance is 222.2%. An analysis of the heat exchanger detailed engineering design (DED) is briefly discussed. To sum up, this research concludes that the shell and tube heat exchangers technology demonstrated a good performance as pre-heating system for the ORC’s hot water circulation system. Further research need to be conducted to examine the performance of heat exchanger system on the ORC’s hot water circulation system.Keywords: shell and tube, heat exchanger, organic Rankine cycle, performance, commissioning
Procedia PDF Downloads 14322603 Thermal Vacuum Chamber Test Result for CubeSat Transmitter
Authors: Fitri D. Jaswar, Tharek A. Rahman, Yasser A. Ahmad
Abstract:
CubeSat in low earth orbit (LEO) mainly uses ultra high frequency (UHF) transmitter with fixed radio frequency (RF) output power to download the telemetry and the payload data. The transmitter consumes large amount of electrical energy during the transmission considering the limited satellite size of a CubeSat. A transmitter with power control ability is designed to achieve optimize the signal to noise ratio (SNR) and efficient power consumption. In this paper, the thermal vacuum chamber (TVAC) test is performed to validate the performance of the UHF band transmitter with power control capability. The TVAC is used to simulate the satellite condition in the outer space environment. The TVAC test was conducted at the Laboratory of Spacecraft Environment Interaction Engineering, Kyushu Institute of Technology, Japan. The TVAC test used 4 thermal cycles starting from +60°C to -20°C for the temperature setting. The pressure condition inside chamber was less than 10-5Pa. During the test, the UHF transmitter is integrated in a CubeSat configuration with other CubeSat subsystem such as on board computer (OBC), power module, and satellite structure. The system is validated and verified through its performance in terms of its frequency stability and the RF output power. The UHF band transmitter output power is tested from 0.5W to 2W according the satellite mode of operations and the satellite power limitations. The frequency stability is measured and the performance obtained is less than 2 ppm in the tested operating temperature range. The test demonstrates the RF output power is adjustable in a thermal vacuum condition.Keywords: communication system, CubeSat, SNR, UHF transmitter
Procedia PDF Downloads 26322602 Control Power in Doubly Fed Induction Generator Wind Turbine with SVM Control Inverter
Authors: Zerzouri Nora, Benalia Nadia, Bensiali Nadia
Abstract:
This paper presents a grid-connected wind power generation scheme using Doubly Fed Induction Generator (DFIG). This can supply power at constant voltage and constant frequency with the rotor speed varying. This makes it suitable for variable speed wind energy application. The DFIG system consists of wind turbine, asynchronous wound rotor induction generator, and inverter with Space Vector Modulation (SVM) controller. In which the stator is connected directly to the grid and the rotor winding is in interface with rotor converter and grid converter. The use of back-to-back SVM converter in the rotor circuit results in low distortion current, reactive power control and operate at variable speed. Mathematical modeling of the DFIG is done in order to analyze the performance of the systems and they are simulated using MATLAB. The simulation results for the system are obtained and hence it shows that the system can operate at variable speed with low harmonic current distortion. The objective is to track and extract maximum power from the wind energy system and transfer it to the grid for useful work.Keywords: Doubly Fed Induction Generator, Wind Energy Conversion Systems, Space Vector Modulation, distortion harmonics
Procedia PDF Downloads 48422601 Performance Evaluation of Wideband Code Division Multiplication Network
Authors: Osama Abdallah Mohammed Enan, Amin Babiker A/Nabi Mustafa
Abstract:
The aim of this study is to evaluate and analyze different parameters of WCDMA (wideband code division multiplication). Moreover, this study also incorporates brief yet throughout analysis of WCDMA’s components as well as its internal architecture. This study also examines different power controls. These power controls may include open loop power control, closed or inner group loop power control and outer loop power control. Different handover techniques or methods of WCDMA are also illustrated in this study. These handovers may include hard handover, inter system handover and soft and softer handover. Different duplexing techniques are also described in the paper. This study has also presented an idea about different parameters of WCDMA that leads the system towards QoS issues. This may help the operator in designing and developing adequate network configuration. In addition to this, the study has also investigated various parameters including Bit Energy per Noise Spectral Density (Eb/No), Noise rise, and Bit Error Rate (BER). After simulating these parameters, using MATLAB environment, it was investigated that, for a given Eb/No value the system capacity increase by increasing the reuse factor. Besides that, it was also analyzed that, noise rise is decreasing for lower data rates and for lower interference levels. Finally, it was examined that, BER increase by using one type of modulation technique than using other type of modulation technique.Keywords: duplexing, handover, loop power control, WCDMA
Procedia PDF Downloads 21422600 Combined PV Cooling and Nighttime Power Generation through Smart Thermal Management of Photovoltaic–Thermoelectric Hybrid Systems
Authors: Abdulrahman M. Alajlan, Saichao Dang, Qiaoqiang Gan
Abstract:
Photovoltaic (PV) cells, while pivotal for solar energy harnessing, confront a challenge due to the presence of persistent residual heat. This thermal energy poses significant obstacles to the performance and longevity of PV cells. Mitigating this thermal issue is imperative, particularly in tropical regions where solar abundance coexists with elevated ambient temperatures. In response, a sustainable and economically viable solution has been devised, incorporating water-passive cooling within a Photovoltaic-Thermoelectric (PV-TEG) hybrid system to address PV cell overheating. The implemented system has significantly reduced the operating temperatures of PV cells, achieving a notable reduction of up to 15 °C below the temperature observed in standalone PV systems. In addition, a thermoelectric generator (TEG) integrated into the system significantly enhances power generation, particularly during nighttime operation. The developed hybrid system demonstrates its capability to generate power at a density of 0.5 Wm⁻² during nighttime, which is sufficient to concurrently power multiple light-emitting diodes, demonstrating practical applications for nighttime power generation. Key findings from this research include a consistent temperature reduction exceeding 10 °C for PV cells, translating to a 5% average enhancement in PV output power compared to standalone PV systems. Experimental demonstrations underscore nighttime power generation of 0.5 Wm⁻², with the potential to achieve 0.8 Wm⁻² through simple geometric optimizations. The optimal cooling of PV cells is determined by the volume of water in the heat storage unit, exhibiting an inverse relationship with the optimal performance for nighttime power generation. Furthermore, the TEG output effectively powers a lighting system with up to 5 LEDs during the night. This research not only proposes a practical solution for maximizing solar radiation utilization but also charts a course for future advancements in energy harvesting technologies.Keywords: photovoltaic-thermoelectric systems, nighttime power generation, PV thermal management, PV cooling
Procedia PDF Downloads 8422599 Harmonics and Flicker Levels at Substation
Authors: Ali Borhani Manesh, Sirus Mohammadi
Abstract:
Harmonic distortion is caused by nonlinear devices in the power system. A nonlinear device is one in which the current is not proportional to the applied voltage. Harmonic distortion is present to some degree on all power systems. Proactive monitoring of power quality disturbance levels by electricity utilities is vital to allow cost-effective mitigation when disturbances are perceived to be approaching planning levels and also to protect the security of customer installations. Ensuring that disturbance levels are within limits at the HV and EHV points of supply of the network is essential if satisfactory levels downstream are to be maintained. This paper presents discussion on a power quality monitoring campaign performed at the sub-transmission point of supply of a distribution network with the objective of benchmarking background disturbance levels prior to modifications to the substation and to ensure emissions from HV customers and the downstream MV networks are within acceptable levels. Some discussion on the difficulties involved in such a study is presented. This paper presents a survey of voltage and current harmonic distortion levels at transmission system in Kohgiloye and Boyrahmad. The effects of harmonics on capacitors and power transformers are discussed.Keywords: power quality, harmonics, flicker, measurement, substation
Procedia PDF Downloads 69622598 Recognition of Arrest Patients and Application of Basic Life Support by Bystanders in the Field
Authors: Behcet Al, Mehmet Murat Oktay, Suat Zengin, Mustafa Sabak, Cuma Yildirim
Abstract:
Objective: Th Recognition of arrest patients and application of basic life support (BLS) by bystanders in the field and the activation of emergency serves were evaluated in present study. Methodology: The present study was carried out by Emergency Department of Medicine Faculty of Gaziantep University at 33 of Emergency Health center in Gaziantep between December 2012- April 2014 prospectively. Of 539 arrested patients, 171 patients were included in study. Results: 118 (69%) male, and 53 31(%) female with a totlay of 171 patients were included in this study. Of patients, 32.2% had syncope and 24% had shorth breathing just befor being arrested. The majority of arrest cases had occured at home (61.4%) and rural area (11.7%) respectively. Of asking help, %48.5 were constructed by family members. Of announcement, only 15.2% occured within first minute of arrest. The BLS ratio that was applied by bystanders was 22.2%. Of bystanders, 47.4% had a course experience of BLS. The emergency serve had reached to the field with a mean of 8.43 min. Of cases, 55% (n=94) were evaluated as exitus firstly bu emergency staff. The most noticed rythim was asystol (73.1%). BLS and advanced life support (ALS) were applied to 98.8% and 60% respectively at the field. 10.5% (n=18) of cases were defibrilated, and 45 (26.3%) were intubated endotrecealy. The majority (48.5%) of staff who applied BLS and ALS at the fied were emergency medicine technicians. CPR was performed to 86.5% (n=148) cases in ambulance while they were transported. The mean arrival time to mergency department was 9.13 min. When the patients arrived to ED 15.2% needed defirlitation. 91.2% (n =156) of patients resulted in exitus in ED. 15 (8.8%) patients were discharged (9 with recovery, six patients with damage). Conclusion: The ratio of inntervention for arrest patients by bystanders is still low. To optain a high percentage of survival, BLS training should be widened among the puplic especiallyamong the caregivers.Keywords: arrest patients, cardiopulmonary resuscitation, bystanders, chest compressions, prehospital
Procedia PDF Downloads 38922597 Electric Load Forecasting Based on Artificial Neural Network for Iraqi Power System
Authors: Afaneen Anwer, Samara M. Kamil
Abstract:
Load Forecast required prediction accuracy based on optimal operation and maintenance. A good accuracy is the basis of economic dispatch, unit commitment, and system reliability. A good load forecasting system fulfilled fast speed, automatic bad data detection, and ability to access the system automatically to get the needed data. In this paper, the formulation of the load forecasting is discussed and the solution is obtained by using artificial neural network method. A MATLAB environment has been used to solve the load forecasting schedule of Iraqi super grid network considering the daily load for three years. The obtained results showed a good accuracy in predicting the forecasted load.Keywords: load forecasting, neural network, back-propagation algorithm, Iraqi power system
Procedia PDF Downloads 58222596 A New Converter Topology for Wind Energy Conversion System
Authors: Mahmoud Khamaira, Ahmed Abu-Siada, Yasser Alharbi
Abstract:
Doubly Fed Induction Generators (DFIGs) are currently extensively used in variable speed wind power plants due to their superior advantages that include reduced converter rating, low cost, reduced losses, easy implementation of power factor correction schemes, variable speed operation and four quadrants active and reactive power control capabilities. On the other hand, DFIG sensitivity to grid disturbances, especially for voltage sags represents the main disadvantage of the equipment. In this paper, a coil is proposed to be integrated within the DFIG converters to improve the overall performance of a DFIG-based wind energy conversion system (WECS). The charging and discharging of the coil are controlled by controlling the duty cycle of the switches of the dc-dc chopper. Simulation results reveal the effectiveness of the proposed topology in improving the overall performance of the WECS system under study.Keywords: doubly fed induction generator, coil, wind energy conversion system, converter topology
Procedia PDF Downloads 66122595 Optimization of Pumping Power of Water between Reservoir Using Ant Colony System
Authors: Thiago Ribeiro De Alencar, Jacyro Gramulia Junior, Patricia Teixeira Leite Asano
Abstract:
The area of the electricity sector that deals with energy needs by the hydropower and thermoelectric in a coordinated way is called Planning Operating Hydrothermal Power Systems. The aim of this area is to find a political operative to provide electrical power to the system in a specified period with minimization of operating cost. This article proposes a computational tool for solving the planning problem. In addition, this article will be introducing a methodology to find new transfer points between reservoirs increasing energy production in hydroelectric power plants cascade systems. The computational tool proposed in this article applies: i) genetic algorithms to optimize the water transfer and operation of hydroelectric plants systems; and ii) Ant Colony algorithm to find the trajectory with the least energy pumping for the construction of pipes transfer between reservoirs considering the topography of the region. The computational tool has a database consisting of 35 hydropower plants and 41 reservoirs, which are part of the southeastern Brazilian system, which has been implemented in an individualized way.Keywords: ant colony system, genetic algorithms, hydroelectric, hydrothermal systems, optimization, water transfer between rivers
Procedia PDF Downloads 32622594 The Determination of Operating Reserve in Small Power Systems Based on Reliability Criteria
Authors: H. Falsafi Falsafizadeh, R. Zeinali Zeinali
Abstract:
This paper focuses on determination of total Operating Reserve (OR) level, consisting of spinning and non-spinning reserves, in two small real power systems, in such a way that the system reliability indicator would comply with typical industry standards. For this purpose, the standard used by the North American Electric Reliability Corporation (NERC) – i.e., 1 day outage in 10 years or 0.1 days/year is relied. The simulation of system operation for these systems that was used for the determination of total operating reserve level was performed by industry standard production simulation software in this field, named PLEXOS. In this paper, the operating reserve which meets an annual Loss of Load Expectation (LOLE) of approximately 0.1 days per year is determined in the study year. This reserve is the minimum amount of reserve required in a power system and generally defined as a percentage of the annual peak.Keywords: frequency control, LOLE, operating reserve, system reliability
Procedia PDF Downloads 34322593 Performance Assessment of PV Based Grid Connected Solar Plant with Varying Load Conditions
Authors: Kusum Tharani, Ratna Dahiya
Abstract:
This paper aims to analyze the power flow of a grid connected 100-kW Photovoltaic(PV) array connected to a 25-kV grid via a DC-DC boost converter and a three-phase three-level Voltage Source Converter (VSC). Maximum Power Point Tracking (MPPT) is implemented in the boost converter bymeans of a Simulink model using the 'Perturb & Observe' technique. First, related papers and technological reports were extensively studied and analyzed. Accordingly, the system is tested under various loading conditions. Power flow analysis is done using the Newton-Raphson method in Matlab environment. Finally, the system is subject to Single Line to Ground Fault and Three Phase short circuit. The results are simulated under the grid-connected operating model.Keywords: grid connected PV Array, Newton-Raphson Method, power flow analysis, three phase fault
Procedia PDF Downloads 55322592 Simulation of Maximum Power Point Tracking in a Photovoltaic System: A Circumstance Using Pulse Width Modulation Analysis
Authors: Asowata Osamede
Abstract:
Optimized gain in respect to output power of stand-alone photovoltaic (PV) systems is one of the major focus of PV in recent times. This is evident to its low carbon emission and efficiency. Power failure or outage from commercial providers in general does not promote development to the public and private sector, these basically limit the development of industries. The need for a well-structured PV system is of importance for an efficient and cost-effective monitoring system. The purpose of this paper is to validate the maximum power point of an off-grid PV system taking into consideration the most effective tilt and orientation angles for PV's in the southern hemisphere. This paper is based on analyzing the system using a solar charger with MPPT from a pulse width modulation (PWM) perspective. The power conditioning device chosen is a solar charger with MPPT. The practical setup consists of a PV panel that is set to an orientation angle of 0o north, with a corresponding tilt angle of 36 o, 26o and 16o. The load employed in this set-up are three Lead Acid Batteries (LAB). The percentage fully charged, charging and not charging conditions are observed for all three batteries. The results obtained in this research is used to draw the conclusion that would provide a benchmark for researchers and scientist worldwide. This is done so as to have an idea of the best tilt and orientation angles for maximum power point in a basic off-grid PV system. A quantitative analysis would be employed in this research. Quantitative research tends to focus on measurement and proof. Inferential statistics are frequently used to generalize what is found about the study sample to the population as a whole. This would involve: selecting and defining the research question, deciding on a study type, deciding on the data collection tools, selecting the sample and its size, analyzing, interpreting and validating findings Preliminary results which include regression analysis (normal probability plot and residual plot using polynomial 6) showed the maximum power point in the system. The best tilt angle for maximum power point tracking proves that the 36o tilt angle provided the best average on time which in turns put the system into a pulse width modulation stage.Keywords: power-conversion, meteonorm, PV panels, DC-DC converters
Procedia PDF Downloads 14622591 Effect of Parameters for Exponential Loads on Voltage Transmission Line with Compensation
Authors: Benalia Nadia, Bensiali Nadia, Zerzouri Noura
Abstract:
This paper presents an analysis of the effects of parameters np and nq for exponential load on the transmission line voltage profile, transferred power and transmission losses for different shunt compensation size. For different values for np and nq in which active and reactive power vary with it is terminal voltages as in exponential form, variations of the load voltage for different sizes of shunt capacitors are simulated with a simple two-bus power system using Matlab SimPowerSystems Toolbox. It is observed that the compensation level is significantly affected by the voltage sensitivities of loads.Keywords: static load model, shunt compensation, transmission system, exponentiel load model
Procedia PDF Downloads 36822590 Optimal Analysis of Grounding System Design for Distribution Substation
Authors: Thong Lantharthong, Nattchote Rugthaicharoencheep, Att Phayomhom
Abstract:
This paper presents the electrical effect of two neighboring distribution substation during the construction phase. The size of auxiliary grounding grid have an effect on entire grounding system. The bigger the size of auxiliary grounding grid, the lower the GPR and maximum touch voltage, with the exception that when the two grids are unconnected, i.e. the bigger the size of auxiliary grounding grid, the higher the maximum step voltage. The results in this paper could be served as design guideline of grounding system, and perhaps remedy of some troublesome grounding grids in power distribution’s system. Modeling and simulation is carried out on the Current Distribution Electromagnetic interference Grounding and Soil structure (CDEGS) program. The simulation results exhibit the design and analysis of power system grounding and perhaps could be set as a standard in grounding system design and modification in distribution substations.Keywords: grounding system, touch voltage, step voltage, safety criteria
Procedia PDF Downloads 450