Search results for: and dose estimation (RADTRAD)
2844 Mobile Smart Application Proposal for Predicting Calories in Food
Authors: Marcos Valdez Alexander Junior, Igor Aguilar-Alonso
Abstract:
Malnutrition is the root of different diseases that universally affect everyone, diseases such as obesity and malnutrition. The objective of this research is to predict the calories of the food to be eaten, developing a smart mobile application to show the user if a meal is balanced. Due to the large percentage of obesity and malnutrition in Peru, the present work is carried out. The development of the intelligent application is proposed with a three-layer architecture, and for the prediction of the nutritional value of the food, the use of pre-trained models based on convolutional neural networks is proposed.Keywords: volume estimation, calorie estimation, artificial vision, food nutrition
Procedia PDF Downloads 1002843 Treatment of Type 2 Diabetes Mellitus: Physicians’ Adherence to the American Diabetes Association Guideline in Central Region, Saudi Arabia
Authors: Ibrahim Mohammed
Abstract:
Background: Diabetes mellitus is a chronic disease that can cause devastating secondary complications, reducing the quality and length of life as well as increasing medical costs for the patient and society. The guidelines recommend both clinical and preventive strategies for diabetes management and are regularly updated. The aim of the study is to assess the level of adherence of physicians to American Diabetes Association Guidelines. Method: Observational multicenter retrospective study will be conducted among different hospitals in the central region. Patient data will be collected from the records of the last three years (2017- 2020). Records will be selected randomly after a complete randomized design. The study focuses on the management of type 2 according to ADA not changed in the last three updating; those standards; all patients should be taking Metformin 1500 to 2000 mg/day as recommended dose and should be received a high dose of statin if the high risk to ASCVD or moderate statin if not at risk, patients with hypertension and diabetes should taking ACE or ARBS. Result: The study aimed to evaluate the commitment of physicians in the central region to the ADA. Out of the 153 selected patients, only 17 % were able to control their diabetes with an average A1c below 7. ADA stated that to reach the minimum benefit of using Metformin, the daily dose should be between 1500 and 2000 mg. Results showed that 110 patients were on Metformin, where 68% of them were on the recommended dose. ADA recommended the intake of high statin for diabetic patients with ASCVD risk, while diabetic patients without ASCVD risk should be on a moderate statin. Results showed that 61.5% of patients with ASCVD risk were at high statin while only 36% of patients without ASCVD risk were at moderate statin. Results showed that 89 patients have hypertension, and 80% of them are getting ACE/ARBs as recommended by the ADA. Recommendation: It is necessary to implement periodic training courses for some physicians to enhance and update their knowledge.Keywords: American Diabetic Association, diabetes mellitus, atherosclerotic cardiovascular disease, ACE inhibitors
Procedia PDF Downloads 862842 Evaluation of Dual Polarization Rainfall Estimation Algorithm Applicability in Korea: A Case Study on Biseulsan Radar
Authors: Chulsang Yoo, Gildo Kim
Abstract:
Dual polarization radar provides comprehensive information about rainfall by measuring multiple parameters. In Korea, for the rainfall estimation, JPOLE and CSU-HIDRO algorithms are generally used. This study evaluated the local applicability of JPOLE and CSU-HIDRO algorithms in Korea by using the observed rainfall data collected on August, 2014 by the Biseulsan dual polarization radar data and KMA AWS. A total of 11,372 pairs of radar-ground rain rate data were classified according to thresholds of synthetic algorithms into suitable and unsuitable data. Then, evaluation criteria were derived by comparing radar rain rate and ground rain rate, respectively, for entire, suitable, unsuitable data. The results are as follows: (1) The radar rain rate equation including KDP, was found better in the rainfall estimation than the other equations for both JPOLE and CSU-HIDRO algorithms. The thresholds were found to be adequately applied for both algorithms including specific differential phase. (2) The radar rain rate equation including horizontal reflectivity and differential reflectivity were found poor compared to the others. The result was not improved even when only the suitable data were applied. Acknowledgments: This work was supported by the Basic Science Research Program through the National Research Foundation of Korea, funded by the Ministry of Education (NRF-2013R1A1A2011012).Keywords: CSU-HIDRO algorithm, dual polarization radar, JPOLE algorithm, radar rainfall estimation algorithm
Procedia PDF Downloads 2152841 X-Ray Dosimetry by a Low-Cost Current Mode Ion Chamber
Authors: Ava Zarif Sanayei, Mustafa Farjad-Fard, Mohammad-Reza Mohammadian-Behbahani, Leyli Ebrahimi, Sedigheh Sina
Abstract:
The fabrication and testing of a low-cost air-filled ion chamber for X-ray dosimetry is studied. The chamber is made of a metal cylinder, a central wire, a BC517 Darlington transistor, a 9V DC battery, and a voltmeter in order to have a cost-effective means to measure the dose. The output current of the dosimeter is amplified by the transistor and then fed to the large internal resistance of the voltmeter, producing a readable voltage signal. The dose-response linearity of the ion chamber is evaluated for different exposure scenarios by the X-ray tube. kVp values 70, 90, and 120, and mAs up to 20 are considered. In all experiments, a solid-state dosimeter (Solidose 400, Elimpex Medizintechnik) is used as a reference device for chamber calibration. Each case of exposure is repeated three times, the voltmeter and Solidose readings are recorded, and the mean and standard deviation values are calculated. Then, the calibration curve, derived by plotting voltmeter readings against Solidose readings, provided a linear fit result for all tube kVps of 70, 90, and 120. A 99, 98, and 100% linear relationship, respectively, for kVp values 70, 90, and 120 are demonstrated. The study shows the feasibility of achieving acceptable dose measurements with a simplified setup. Further enhancements to the proposed setup include solutions for limiting the leakage current, optimizing chamber dimensions, utilizing electronic microcontrollers for dedicated data readout, and minimizing the impact of stray electromagnetic fields on the system.Keywords: dosimetry, ion chamber, radiation detection, X-ray
Procedia PDF Downloads 802840 Improved Distance Estimation in Dynamic Environments through Multi-Sensor Fusion with Extended Kalman Filter
Authors: Iffat Ara Ebu, Fahmida Islam, Mohammad Abdus Shahid Rafi, Mahfuzur Rahman, Umar Iqbal, John Ball
Abstract:
The application of multi-sensor fusion for enhanced distance estimation accuracy in dynamic environments is crucial for advanced driver assistance systems (ADAS) and autonomous vehicles. Limitations of single sensors such as cameras or radar in adverse conditions motivate the use of combined camera and radar data to improve reliability, adaptability, and object recognition. A multi-sensor fusion approach using an extended Kalman filter (EKF) is proposed to combine sensor measurements with a dynamic system model, achieving robust and accurate distance estimation. The research utilizes the Mississippi State University Autonomous Vehicular Simulator (MAVS) to create a controlled environment for data collection. Data analysis is performed using MATLAB. Qualitative (visualization of fused data vs ground truth) and quantitative metrics (RMSE, MAE) are employed for performance assessment. Initial results with simulated data demonstrate accurate distance estimation compared to individual sensors. The optimal sensor measurement noise variance and plant noise variance parameters within the EKF are identified, and the algorithm is validated with real-world data from a Chevrolet Blazer. In summary, this research demonstrates that multi-sensor fusion with an EKF significantly improves distance estimation accuracy in dynamic environments. This is supported by comprehensive evaluation metrics, with validation transitioning from simulated to real-world data, paving the way for safer and more reliable autonomous vehicle control.Keywords: sensor fusion, EKF, MATLAB, MAVS, autonomous vehicle, ADAS
Procedia PDF Downloads 462839 Biomass Carbon Credit Estimation for Sustainable Urban Planning and Micro-climate Assessment
Authors: R. Niranchana, K. Meena Alias Jeyanthi
Abstract:
As a result of the present climate change dilemma, the energy balancing strategy is to construct a sustainable environment has become a top concern for researchers worldwide. The environment itself has always been a solution from the earliest days of human evolution. Carbon capture begins with its accurate estimation and monitoring credit inventories, and its efficient use. Sustainable urban planning with deliverables of re-use energy models might benefit from assessment methods like biomass carbon credit ranking. The term "biomass energy" refers to the various ways in which living organisms can potentially be converted into a source of energy. The approaches that can be applied to biomass and an algorithm for evaluating carbon credits are presented in this paper. The micro-climate evaluation using Computational Fluid dynamics was carried out across the location (1 km x1 km) at Dindigul, India (10°24'58.68" North, 77°54.1.80 East). Sustainable Urban design must be carried out considering environmental and physiological convection, conduction, radiation and evaporative heat exchange due to proceeding solar access and wind intensities.Keywords: biomass, climate assessment, urban planning, multi-regression, carbon estimation algorithm
Procedia PDF Downloads 972838 The acute effects caffeine on testosterone and cortisol in young football players after One Session Anaerobic exercise
Authors: S. Rostami, S. H. Hosseini, A. A. Torabi, M. Bekhradi
Abstract:
Introduction: Interest in the use of caffeine as an ergogenic aid has increased since the International Olympic Committee lifted the partial ban on its use. Caffeine has beneficial effects on various aspects of athletic performance, but its effects on training have been neglected. The purpose of this study was to investigate the acute effect of caffeine on testosterone and cortisole in young futsal players. Methods: Twenty-four professional futsal players with 18.3± 1.9 years ingested caffeine doses of 0, 200 and 800 mg in random order 1 hr before an anaerobic-exercise session (RAST test). Samples were taken at the time of caffeine ingestion and 30 min after the session. Data were log-transformed to estimate percent effects with mixed modeling, and effects were standardized to assess magnitudes. fects on training have been neglected. Results: Testosterone concentration showed a small increase of 15% (90% confidence limits, ± 19%) during exercise. Caffeine raised this concentration in a dose-dependent manner by a further small 21% (± 24%) at the highest dose. The 800-mg dose also produced a moderate 52% (± 44%) increase in cortisol. The effect of caffeine on the testosterone: cortisol ratio was a small decline (14%; ± 21%). Discussion and Conclusion: Caffeine has some potential to benefit training outcomes via the anabolic effects of the increase in testosterone concentration, but this benefit might be counteracted by the opposing catabolic effects of the increase in cortisol and resultant decline in the testosterone: cortisol ratio.Keywords: anabolic, catabolic, performance, testosterone, cortisol ratio, RAST test
Procedia PDF Downloads 4412837 Switched System Diagnosis Based on Intelligent State Filtering with Unknown Models
Authors: Nada Slimane, Foued Theljani, Faouzi Bouani
Abstract:
The paper addresses the problem of fault diagnosis for systems operating in several modes (normal or faulty) based on states assessment. We use, for this purpose, a methodology consisting of three main processes: 1) sequential data clustering, 2) linear model regression and 3) state filtering. Typically, Kalman Filter (KF) is an algorithm that provides estimation of unknown states using a sequence of I/O measurements. Inevitably, although it is an efficient technique for state estimation, it presents two main weaknesses. First, it merely predicts states without being able to isolate/classify them according to their different operating modes, whether normal or faulty modes. To deal with this dilemma, the KF is endowed with an extra clustering step based fully on sequential version of the k-means algorithm. Second, to provide state estimation, KF requires state space models, which can be unknown. A linear regularized regression is used to identify the required models. To prove its effectiveness, the proposed approach is assessed on a simulated benchmark.Keywords: clustering, diagnosis, Kalman Filtering, k-means, regularized regression
Procedia PDF Downloads 1832836 The Generalized Pareto Distribution as a Model for Sequential Order Statistics
Authors: Mahdy Esmailian, Mahdi Doostparast, Ahmad Parsian
Abstract:
In this article, sequential order statistics (SOS) censoring type II samples coming from the generalized Pareto distribution are considered. Maximum likelihood (ML) estimators of the unknown parameters are derived on the basis of the available multiple SOS data. Necessary conditions for existence and uniqueness of the derived ML estimates are given. Due to complexity in the proposed likelihood function, a useful re-parametrization is suggested. For illustrative purposes, a Monte Carlo simulation study is conducted and an illustrative example is analysed.Keywords: bayesian estimation, generalized pareto distribution, maximum likelihood estimation, sequential order statistics
Procedia PDF Downloads 5122835 High-Dose-Rate Brachytherapy for Cervical Cancer: The Effect of Total Reference Air Kerma on the Results of Single-Channel and Tri-Channel Applicators
Authors: Hossain A., Miah S., Ray P. K.
Abstract:
Introduction: Single channel and tri-channel applicators are used in the traditional treatment of cervical cancer. Total reference air kerma (TRAK) and treatment outcomes in high-dose-rate brachytherapy for cervical cancer using single-channel and tri-channel applicators were the main objectives of this retrospective study. Material and Methods: Patients in the radiotherapy division who received brachytherapy, chemotherapy, and external radiotherapy (EBRT) using single and tri-channel applicators were the subjects of a retrospective cohort study from 2016 to 2020. All brachytherapy parameters, including TRAK, were calculated in accordance with the international protocol. The Kaplan Meier method was used to analyze survival rates using a log-rank test. Results and Discussions: Based on treatment times of 15.34 (10-20) days and 21.35 (6.5-28) days, the TRAK for the tri-channel applicator was 0.52 cGy.m² and for the single-channel applicator was 0.34 cGy.m². Based on TRAK, the rectum, bladder, and tumor had respective Pearson correlations of 0.082, 0.009, and 0.032. The 1-specificity and sensitivity were 0.70 and 0.30, respectively. At that time, AUC was 0.71. The log-rank test showed that tri-channel applicators had a survival rate of 95% and single-channel applicators had a survival rate of 85% (p=0.565). Conclusions: The relationship between TRAK and treatment duration and Pearson correlation for the tumor, rectum, and bladder suggests that TRAK should be taken into account for the proper operation of single channel and tri-channel applicators.Keywords: single-channel, tri-channel, high dose rate brachytherapy, cervical cancer
Procedia PDF Downloads 1012834 Evaluating Radiation Dose for Interventional Radiologists Performing Spine Procedures
Authors: Kholood A. Baron
Abstract:
While radiologist numbers specialized in spine interventional procedures are limited in Kuwait, the number of patients demanding these procedures is increasing rapidly. Due to this high demand, the workload of radiologists is increasing, which might represent a radiation exposure concern. During these procedures, the doctor’s hands are in very close proximity to the main radiation beam/ if not within it. The aim of this study is to measure the radiation dose for radiologists during several interventional procedures for the spine. Methods: Two doctors carrying different workloads were included. (DR1) was performing procedures in the morning and afternoon shifts, while (DR2) was performing procedures in the morning shift only. Comparing the radiation exposures that the hand of each doctor is receiving will assess radiation safety and help to set up workload regulations for radiologists carrying a heavy schedule of such procedures. Entrance Skin Dose (ESD) was measured via TLD (ThermoLuminescent Dosimetry) placed at the right wrist of the radiologists. DR1 was covering the morning shift in one hospital (Mubarak Al-Kabeer Hospital) and the afternoon shift in another hospital (Dar Alshifa Hospital). The TLD chip was placed in his gloves during the 2 shifts for a whole week. Since DR2 was covering the morning shift only in Al Razi Hospital, he wore the TLD during the morning shift for a week. It is worth mentioning that DR1 was performing 4-5 spine procedures/day in the morning and the same number in the afternoon and DR2 was performing 5-7 procedures/day. This procedure was repeated for 4 consecutive weeks in order to calculate the ESD value that a hand receives in a month. Results: In general, radiation doses that the hand received in a week ranged from 0.12 to 1.12 mSv. The ESD values for DR1 for the four consecutive weeks were 1.12, 0.32, 0.83, 0.22 mSv, thus for a month (4 weeks), this equals 2.49 mSv and calculated to be 27.39 per year (11 months-since each radiologist have 45 days of leave in each year). For DR2, the weekly ESD values are 0.43, 0.74, 0.12, 0.61 mSv, and thus, for a month, this equals 1.9 mSv, and for a year, this equals 20.9 mSv /year. These values are below the standard level and way below the maximum limit of 500 mSv per year (set by ICRP = International Council of Radiation Protection). However, it is worth mentioning that DR1 was a senior consultant and hence needed less fluoro-time during each procedure. This is evident from the low ESD values of the second week (0.32) and the fourth week (0.22), even though he was performing nearly 10-12 procedures in a day /5 days a week. These values were lower or in the same range as those for DR2 (who was a junior consultant). This highlighted the importance of increasing the radiologist's skills and awareness of fluoroscopy time effect. In conclusion, the radiation dose that radiologists received during spine interventional radiology in our setting was below standard dose limits.Keywords: radiation protection, interventional radiology dosimetry, ESD measurements, radiologist radiation exposure
Procedia PDF Downloads 592833 Analysis of Cell Cycle Status in Radiation Non-Targeted Hepatoma Cells Using Flow Cytometry: Evidence of Dose Dependent Response
Authors: Sharmi Mukherjee, Anindita Chakraborty
Abstract:
Cellular irradiation incites complex responses including arrest of cell cycle progression. This article accentuates the effects of radiation on cell cycle status of radiation non-targeted cells. Human Hepatoma HepG2 cells were exposed to increasing doses of γ radiations (1, 2, 4, 6 Gy) and their cell culture media was transferred to non-targeted HepG2 cells cultured in other Petri plates. These radiation non-targeted cells cultured in the ICCM (Irradiated cell conditioned media) were the bystander cells on which cell cycle analysis was performed using flow cytometry. An apparent decrease in the distribution of bystander cells at G0/G1 phase was observed with increased radiation doses upto 4 Gy representing a linear relationship. This was accompanied by a gradual increase in cellular distribution at G2/M phase. Interestingly the number of cells in G2/M phase at 1 and 2 Gy irradiation was not significantly different from each other. However, the percentage of G2 phase cells at 4 and 6 Gy doses were significantly higher than 2 Gy dose indicating the IC50 dose to be between 2 and 4 Gy. Cell cycle arrest is an indirect indicator of genotoxic damage in cells. In this study, bystander stress signals through the cell culture media of irradiated cells disseminated the radiation induced DNA damages in the non-targeted cells which resulted in arrest of the cell cycle progression at G2/M phase checkpoint. This implies that actual radiation biological effects represent a penumbra with effects encompassing a larger area than the actual beam. This article highlights the existence of genotoxic damages as bystander effects of γ rays in human Hepatoma cells by cell cycle analysis and opens up avenues for appraisal of bystander stress communications between tumor cells. Contemplation of underlying signaling mechanisms can be manipulated to maximize damaging effects of radiation with minimum dose and thus has therapeutic applications.Keywords: bystander effect, cell cycle, genotoxic damage, hepatoma
Procedia PDF Downloads 1842832 Construction Unit Rate Factor Modelling Using Neural Networks
Authors: Balimu Mwiya, Mundia Muya, Chabota Kaliba, Peter Mukalula
Abstract:
Factors affecting construction unit cost vary depending on a country’s political, economic, social and technological inclinations. Factors affecting construction costs have been studied from various perspectives. Analysis of cost factors requires an appreciation of a country’s practices. Identified cost factors provide an indication of a country’s construction economic strata. The purpose of this paper is to identify the essential factors that affect unit cost estimation and their breakdown using artificial neural networks. Twenty-five (25) identified cost factors in road construction were subjected to a questionnaire survey and employing SPSS factor analysis the factors were reduced to eight. The 8 factors were analysed using the neural network (NN) to determine the proportionate breakdown of the cost factors in a given construction unit rate. NN predicted that political environment accounted 44% of the unit rate followed by contractor capacity at 22% and financial delays, project feasibility, overhead and profit each at 11%. Project location, material availability and corruption perception index had minimal impact on the unit cost from the training data provided. Quantified cost factors can be incorporated in unit cost estimation models (UCEM) to produce more accurate estimates. This can create improvements in the cost estimation of infrastructure projects and establish a benchmark standard to assist the process of alignment of work practises and training of new staff, permitting the on-going development of best practises in cost estimation to become more effective.Keywords: construction cost factors, neural networks, roadworks, Zambian construction industry
Procedia PDF Downloads 3652831 Monte Carlo Simulation of X-Ray Spectra in Diagnostic Radiology and Mammography Using MCNP4C
Authors: Sahar Heidary, Ramin Ghasemi Shayan
Abstract:
The overall goal Monte Carlo N-atom radioactivity transference PC program (MCNP4C) was done for the regeneration of x-ray groups in diagnostic radiology and mammography. The electrons were transported till they slow down and stopover in the target. Both bremsstrahlung and characteristic x-ray creation were measured in this study. In this issue, the x-ray spectra forecast by several computational models recycled in the diagnostic radiology and mammography energy kind have been calculated by appraisal with dignified spectra and their outcome on the scheming of absorbed dose and effective dose (ED) told to the adult ORNL hermaphroditic phantom quantified. This comprises practical models (TASMIP and MASMIP), semi-practical models (X-rayb&m, X-raytbc, XCOMP, IPEM, Tucker et al., and Blough et al.), and Monte Carlo modeling (EGS4, ITS3.0, and MCNP4C). Images got consuming synchrotron radiation (SR) and both screen-film and the CR system were related with images of the similar trials attained with digital mammography equipment. In sight of the worthy feature of the effects gained, the CR system was used in two mammographic inspections with SR. For separately mammography unit, the capability acquiesced bilateral mediolateral oblique (MLO) and craniocaudal(CC) mammograms attained in a woman with fatty breasts and a woman with dense breasts. Referees planned the common groups and definite absences that managed to a choice to miscarry the part that formed the scientific imaginings.Keywords: mammography, monte carlo, effective dose, radiology
Procedia PDF Downloads 1312830 Robust Heart Rate Estimation from Multiple Cardiovascular and Non-Cardiovascular Physiological Signals Using Signal Quality Indices and Kalman Filter
Authors: Shalini Rankawat, Mansi Rankawat, Rahul Dubey, Mazad Zaveri
Abstract:
Physiological signals such as electrocardiogram (ECG) and arterial blood pressure (ABP) in the intensive care unit (ICU) are often seriously corrupted by noise, artifacts, and missing data, which lead to errors in the estimation of heart rate (HR) and incidences of false alarm from ICU monitors. Clinical support in ICU requires most reliable heart rate estimation. Cardiac activity, because of its relatively high electrical energy, may introduce artifacts in Electroencephalogram (EEG), Electrooculogram (EOG), and Electromyogram (EMG) recordings. This paper presents a robust heart rate estimation method by detection of R-peaks of ECG artifacts in EEG, EMG & EOG signals, using energy-based function and a novel Signal Quality Index (SQI) assessment technique. SQIs of physiological signals (EEG, EMG, & EOG) were obtained by correlation of nonlinear energy operator (teager energy) of these signals with either ECG or ABP signal. HR is estimated from ECG, ABP, EEG, EMG, and EOG signals from separate Kalman filter based upon individual SQIs. Data fusion of each HR estimate was then performed by weighing each estimate by the Kalman filters’ SQI modified innovations. The fused signal HR estimate is more accurate and robust than any of the individual HR estimate. This method was evaluated on MIMIC II data base of PhysioNet from bedside monitors of ICU patients. The method provides an accurate HR estimate even in the presence of noise and artifacts.Keywords: ECG, ABP, EEG, EMG, EOG, ECG artifacts, Teager-Kaiser energy, heart rate, signal quality index, Kalman filter, data fusion
Procedia PDF Downloads 6962829 Extended Kalman Filter Based Direct Torque Control of Permanent Magnet Synchronous Motor
Authors: Liang Qin, Hanan M. D. Habbi
Abstract:
A robust sensorless speed for permanent magnet synchronous motor (PMSM) has been presented for estimation of stator flux components and rotor speed based on The Extended Kalman Filter (EKF). The model of PMSM and its EKF models are modeled in Matlab /Sirnulink environment. The proposed EKF speed estimation method is also proved insensitive to the PMSM parameter variations. Simulation results demonstrate a good performance and robustness.Keywords: DTC, Extended Kalman Filter (EKF), PMSM, sensorless control, anti-windup PI
Procedia PDF Downloads 6652828 Ytterbium Advantages for Brachytherapy
Authors: S. V. Akulinichev, S. A. Chaushansky, V. I. Derzhiev
Abstract:
High dose rate (HDR) brachytherapy is a method of contact radiotherapy, when a single sealed source with an activity of about 10 Ci is temporarily inserted in the tumor area. The isotopes Ir-192 and (much less) Co-60 are used as active material for such sources. The other type of brachytherapy, the low dose rate (LDR) brachytherapy, implies the insertion of many permanent sources (up to 200) of lower activity. The pulse dose rate (PDR) brachytherapy can be considered as a modification of HDR brachytherapy, when the single source is repeatedly introduced in the tumor region in a pulse regime during several hours. The PDR source activity is of the order of one Ci and the isotope Ir-192 is currently used for these sources. The PDR brachytherapy is well recommended for the treatment of several tumors since, according to oncologists, it combines the medical benefits of both HDR and LDR types of brachytherapy. One of the main problems for the PDR brachytherapy progress is the shielding of the treatment area since the longer stay of patients in a shielded canyon is not enough comfortable for them. The use of Yb-169 as an active source material is the way to resolve the shielding problem for PDR, as well as for HRD brachytherapy. The isotope Yb-169 has the average photon emission energy of 93 KeV and the half-life of 32 days. Compared to iridium and cobalt, this isotope has a significantly lower emission energy and therefore requires a much lighter shielding. Moreover, the absorption cross section of different materials has a strong Z-dependence in that photon energy range. For example, the dose distributions of iridium and ytterbium have a quite similar behavior in the water or in the body. But the heavier material as lead absorbs the ytterbium radiation much stronger than the iridium or cobalt radiation. For example, only 2 mm of lead layer is enough to reduce the ytterbium radiation by a couple of orders of magnitude but is not enough to protect from iridium radiation. We have created an original facility to produce the start stable isotope Yb-168 using the laser technology AVLIS. This facility allows to raise the Yb-168 concentration up to 50 % and consumes much less of electrical power than the alternative electromagnetic enrichment facilities. We also developed, in cooperation with the Institute of high pressure physics of RAS, a new technology for manufacturing high-density ceramic cores of ytterbium oxide. Ceramics density reaches the limit of the theoretical values: 9.1 g/cm3 for the cubic phase of ytterbium oxide and 10 g/cm3 for the monoclinic phase. Source cores from this ceramics have high mechanical characteristics and a glassy surface. The use of ceramics allows to increase the source activity with fixed external dimensions of sources.Keywords: brachytherapy, high, pulse dose rates, radionuclides for therapy, ytterbium sources
Procedia PDF Downloads 4922827 DOA Estimation Using Golden Section Search
Authors: Niharika Verma, Sandeep Santosh
Abstract:
DOA technique is a localization technique used in the communication field. Various algorithms have been developed for direction of arrival estimation like MUSIC, ROOT MUSIC, etc. These algorithms depend on various parameters like antenna array elements, number of snapshots and various others. Basically the MUSIC spectrum is evaluated and peaks obtained are considered as the angle of arrivals. The angles evaluated using this process depends on the scanning interval chosen. The accuracy of the results obtained depends on the coarseness of the interval chosen. In this paper, golden section search is applied to the MUSIC algorithm and therefore, more accurate results are achieved. Initially the coarse DOA estimations is done using the MUSIC algorithm in the range -90 to 90 degree at the interval of 10 degree. After the peaks obtained then fine DOA estimation is done using golden section search. Also, the partitioning method is applied to estimate the number of signals incident on the antenna array. Dependency of the algorithm on the number of snapshots is also being explained. Hence, the accurate results are being determined using this algorithm.Keywords: Direction of Arrival (DOA), golden section search, MUSIC, number of snapshots
Procedia PDF Downloads 4472826 Alternative Mathematical form for Determining the Effectiveness of High-LET Radiations at Lower Doses Region
Authors: Abubaker A. Yousif, Muhamad S. Yasir
Abstract:
The Effectiveness of lower doses of high-LET radiations is not accurately determined by using energy-based physical parameters such as absorbed dose and radio-sensitivity parameters. Therefore, an attempt has been carried out in this research to propose alternative parameter that capable to quantify the effectiveness of these high LET radiations at lower doses regions. The linear energy transfer and mean free path are employed to achieve this objective. A new mathematical form of the effectiveness of high-LET radiations at lower doses region has been formulated. Based on this parameter, the optimized effectiveness of high-LET radiations occurs when the energy of charged particles is deposited at spacing of 2 nm for primary ionization.Keywords: effectiveness, low dose, radiation mean free path, linear energy transfer
Procedia PDF Downloads 4622825 Exponentiated Transmuted Weibull Distribution: A Generalization of the Weibull Probability Distribution
Authors: Abd El Hady N. Ebraheim
Abstract:
This paper introduces a new generalization of the two parameter Weibull distribution. To this end, the quadratic rank transmutation map has been used. This new distribution is named exponentiated transmuted Weibull (ETW) distribution. The ETW distribution has the advantage of being capable of modeling various shapes of aging and failure criteria. Furthermore, eleven lifetime distributions such as the Weibull, exponentiated Weibull, Rayleigh and exponential distributions, among others follow as special cases. The properties of the new model are discussed and the maximum likelihood estimation is used to estimate the parameters. Explicit expressions are derived for the quantiles. The moments of the distribution are derived, and the order statistics are examined.Keywords: exponentiated, inversion method, maximum likelihood estimation, transmutation map
Procedia PDF Downloads 5662824 In vivo Determination of Anticoagulant Property of the Tentacle Extract of Aurelia aurita (Moon Jellyfish) Using Sprague-Dawley Rats
Authors: Bea Carmel H. Casiding, Charmaine A. Guy, Funny Jovis P. Malasan, Katrina Chelsea B. Manlutac, Danielle Ann N. Novilla, Marianne R. Oliveros, Magnolia C. Sibulo
Abstract:
Moon jellyfish, Aurelia aurita, has become a popular research organism for diverse studies. Recent studies have verified the prevention of blood clotting properties of the moon jellyfish tentacle extract through in vitro methods. The purpose of this study was to validate the blood clotting ability of A. aurita tentacle extract using in vivo method of experimentation. The tentacles of A. aurita jellyfish were excised and filtered then centrifuged at 3000xg for 10 minutes. The crude nematocyst extract was suspended in 1:6 ratios with phosphate buffer solution and sonicated for three periods of 20 seconds each at 50 Hz. Protein concentration of the extract was determined using Bradford Assay. Bovine serum albumin was the standard solution used with the following concentrations: 35.0, 70.0, 105.0, 140.0, 175.0, 210.0, 245.0, and 280.0 µg/mL. The absorbance was read at 595 nm. Toxicity testing from OECD guidelines was adapted. The extract suspended in phosphate-buffered saline solution was arbitrarily set into three doses (0.1mg/kg, 0.3mg/kg, 0.5mg/kg) and were administered daily for five days to the experimental groups of five male Sprague-Dawley rats (one dose per group). Before and after the administration period, bleeding time and clotting time tests were performed. The One-way Analysis of Variance (ANOVA) was used to analyze the difference of before and after bleeding time and clotting time from the three treatment groups, time, positive and negative control groups. The average protein concentration of the sonicated crude tentacle extract was 206.5 µg/mL. The highest dose administered (0.5mg/kg) produced significant increase in the time for both bleeding and clotting tests. However, the preceding lower dose (0.3mg/kg) only was significantly effective for clotting time test. The protein contained in the tentacle extract with a concentration of 206.5 mcg/mL and dose of 0.3 mg/kg and 0.5 mg/kg of A. aurita elicited anticoagulating activity.Keywords: anticoagulant, bleeding time test, clotting time test, moon jellyfish
Procedia PDF Downloads 3982823 Bio-Equivalence of Doxycycline in Two Preparations in Broiler Chickens
Authors: Abdelrazzag Elmajdoub
Abstract:
The present study was designed to investigate the bio-equivalence of doxycycline in Dolistin® and Colidox® at a dose rate of 10 mg doxycycline/kg of body weight in 48 clinically normal broiler chickens. After oral administration, plasma levels of doxycycline peaked after 2 hours post-dosing without significant differences between the two products and it could be detected therapeutically and exceeded the minimum inhibitory concentration (MIC) for most micro-organisms sensitive to doxycycline for 12 hours. The disposition kinetics of doxycycline in the two products following oral administration revealed that the maximum plasma concentrations (Cmax.) were 22.65 and 21.80 µg/ml and attained at (Tmax.) 2.10 and 2.20 hours, respectively. Doxycycline in both of the products was eliminated with half- lives (t0.5α) equal to 7.70 and 6.93 hours, respectively. The mean systemic bio availabilities of doxycycline in both of the products after oral administration in chickens were 80.60 and 79.70%, respectively. It was concluded that doxycycline in the form of Dolistin® and Colidox® needs a dose equivalent to 20 mg doxycycline/kg of body weight a day is better to keep the plasma concentration higher than the MIC.Keywords: tetracyclines, doxycycline, bioavailability, broilers, chickens
Procedia PDF Downloads 5062822 Unconventional Dating of Old Peepal Tree of Chandigarh (India) Using Optically Stimulated Luminescence
Authors: Rita Rani, Ramesh Kumar
Abstract:
The intend of the current study is to date an old grand Peepal tree that is still alive. The tree is situated in Kalibard village, Sector 9, Chandigarh (India). Due to its huge structure, it has got the status of ‘Heritage tree.’ Optically Stimulated Luminescence of sediments beneath the roots is used to determine the age of the tree. Optical dating is preferred over conventional dating methods due to more precession. The methodology includes OSL of quartz grain using SAR protocol for accumulated dose measurement. The age determination of an alive tree using sedimentary quartz is in close agreement with the approximated age provided by the related agency. This is the first attempt at using optically stimulated luminescence in the age determination of alive trees in this region. The study concludes that the Luminescence dating of alive trees is the nondestructive and more precise method.Keywords: luminescence, dose rate, optical dating, sediments
Procedia PDF Downloads 1762821 Comparison of Statistical Methods for Estimating Missing Precipitation Data in the River Subbasin Lenguazaque, Colombia
Authors: Miguel Cañon, Darwin Mena, Ivan Cabeza
Abstract:
In this work was compared and evaluated the applicability of statistical methods for the estimation of missing precipitations data in the basin of the river Lenguazaque located in the departments of Cundinamarca and Boyacá, Colombia. The methods used were the method of simple linear regression, distance rate, local averages, mean rates, correlation with nearly stations and multiple regression method. The analysis used to determine the effectiveness of the methods is performed by using three statistical tools, the correlation coefficient (r2), standard error of estimation and the test of agreement of Bland and Altmant. The analysis was performed using real rainfall values removed randomly in each of the seasons and then estimated using the methodologies mentioned to complete the missing data values. So it was determined that the methods with the highest performance and accuracy in the estimation of data according to conditions that were counted are the method of multiple regressions with three nearby stations and a random application scheme supported in the precipitation behavior of related data sets.Keywords: statistical comparison, precipitation data, river subbasin, Bland and Altmant
Procedia PDF Downloads 4682820 Age Estimation from Teeth among North Indian Population: Comparison and Reliability of Qualitative and Quantitative Methods
Authors: Jasbir Arora, Indu Talwar, Daisy Sahni, Vidya Rattan
Abstract:
Introduction: Age estimation is a crucial step to build the identity of a person, both in case of deceased and alive. In adults, age can be estimated on the basis of six regressive (Attrition, Secondary dentine, Dentine transparency, Root resorption, Cementum apposition and Periodontal Disease) changes in teeth qualitatively using scoring system and quantitatively by micrometric method. The present research was designed to establish the reliability of qualitative (method 1) and quantitative (method 2) of age estimation among North Indians and to compare the efficacy of these two methods. Method: 250 single-rooted extracted teeth (18-75 yrs.) were collected from Department of Oral Health Sciences, PGIMER, Chandigarh. Before extraction, periodontal score of each tooth was noted. Labiolingual sections were prepared and examined under light microscope for regressive changes. Each parameter was scored using Gustafson’s 0-3 point score system (qualitative), and total score was calculated. For quantitative method, each regressive change was measured quantitatively in form of 18 micrometric parameters under microscope with the help of measuring eyepiece. Age was estimated using linear and multiple regression analysis in Gustafson’s method and Kedici’s method respectively. Estimated age was compared with actual age on the basis of absolute mean error. Results: In pooled data, by Gustafson’s method, significant correlation (r= 0.8) was observed between total score and actual age. Total score generated an absolute mean error of ±7.8 years. Whereas, for Kedici’s method, a value of correlation coefficient of r=0.5 (p<0.01) was observed between all the eighteen micrometric parameters and known age. Using multiple regression equation, age was estimated, and an absolute mean error of age was found to be ±12.18 years. Conclusion: Gustafson’s (qualitative) method was found to be a better predictor for age estimation among North Indians.Keywords: forensic odontology, age estimation, North India, teeth
Procedia PDF Downloads 2422819 Median-Based Nonparametric Estimation of Returns in Mean-Downside Risk Portfolio Frontier
Authors: H. Ben Salah, A. Gannoun, C. de Peretti, A. Trabelsi
Abstract:
The Downside Risk (DSR) model for portfolio optimisation allows to overcome the drawbacks of the classical mean-variance model concerning the asymetry of returns and the risk perception of investors. This model optimization deals with a positive definite matrix that is endogenous with respect to portfolio weights. This aspect makes the problem far more difficult to handle. For this purpose, Athayde (2001) developped a new recurcive minimization procedure that ensures the convergence to the solution. However, when a finite number of observations is available, the portfolio frontier presents an appearance which is not very smooth. In order to overcome that, Athayde (2003) proposed a mean kernel estimation of the returns, so as to create a smoother portfolio frontier. This technique provides an effect similar to the case in which we had continuous observations. In this paper, taking advantage on the the robustness of the median, we replace the mean estimator in Athayde's model by a nonparametric median estimator of the returns. Then, we give a new version of the former algorithm (of Athayde (2001, 2003)). We eventually analyse the properties of this improved portfolio frontier and apply this new method on real examples.Keywords: Downside Risk, Kernel Method, Median, Nonparametric Estimation, Semivariance
Procedia PDF Downloads 4932818 Ratio Type Estimators for the Estimation of Population Coefficient of Variation under Two-Stage Sampling
Authors: Muhammad Jabbar
Abstract:
In this paper we propose two ratio and ratio type exponential estimator for the estimation of population coefficient of variation using the auxiliary information under two-stage sampling. The properties of these estimators are derived up to first order of approximation. The efficiency conditions under which suggested estimator are more efficient, are obtained. Numerical and simulated studies are conducted to support the superiority of the estimators. Theoretically and numerically, we have found that our proposed estimator is always more efficient as compared to its competitor estimator.Keywords: two-stage sampling, coefficient of variation, ratio type exponential estimator
Procedia PDF Downloads 5292817 Integrating Deep Learning For Improved State Of Charge Estimation In Electric Bus
Authors: Ms. Hema Ramachandran, Dr. N. Vasudevan
Abstract:
Accurate estimation of the battery State of Charge (SOC) is essential for optimizing the range and performance of modern electric vehicles. This paper focuses on analysing historical driving data from electric buses, with an emphasis on feature extraction and data preprocessing of driving conditions. By selecting relevant parameters, a set of characteristic variables tailored to specific driving scenarios is established. A battery SOC prediction model based on a combination a bidirectional long short-term memory (LSTM) architecture and a standard fully connected neural network (FCNN) is then proposed, where various hyperparameters are identified and fine-tuned to enhance prediction accuracy. The results indicate that with optimized hyperparameters, the prediction achieves a Root Mean Square Error (RMSE) of 1.98% and a Mean Absolute Error (MAE) of 1.72%. This approach is expected to improve the efficiency of battery management systems and battery utilization in electric vehicles.Keywords: long short-term memory (lstm), battery health monitoring, data-driven models, battery charge-discharge cycles, adaptive soc estimation, voltage and current sensing
Procedia PDF Downloads 72816 The Evaluation of the Performance of Different Filtering Approaches in Tracking Problem and the Effect of Noise Variance
Authors: Mohammad Javad Mollakazemi, Farhad Asadi, Aref Ghafouri
Abstract:
Performance of different filtering approaches depends on modeling of dynamical system and algorithm structure. For modeling and smoothing the data the evaluation of posterior distribution in different filtering approach should be chosen carefully. In this paper different filtering approaches like filter KALMAN, EKF, UKF, EKS and smoother RTS is simulated in some trajectory tracking of path and accuracy and limitation of these approaches are explained. Then probability of model with different filters is compered and finally the effect of the noise variance to estimation is described with simulations results.Keywords: Gaussian approximation, Kalman smoother, parameter estimation, noise variance
Procedia PDF Downloads 4392815 Genetic Algorithm and Multi Criteria Decision Making Approach for Compressive Sensing Based Direction of Arrival Estimation
Authors: Ekin Nurbaş
Abstract:
One of the essential challenges in array signal processing, which has drawn enormous research interest over the past several decades, is estimating the direction of arrival (DOA) of plane waves impinging on an array of sensors. In recent years, the Compressive Sensing based DoA estimation methods have been proposed by researchers, and it has been discovered that the Compressive Sensing (CS)-based algorithms achieved significant performances for DoA estimation even in scenarios where there are multiple coherent sources. On the other hand, the Genetic Algorithm, which is a method that provides a solution strategy inspired by natural selection, has been used in sparse representation problems in recent years and provides significant improvements in performance. With all of those in consideration, in this paper, a method that combines the Genetic Algorithm (GA) and the Multi-Criteria Decision Making (MCDM) approaches for Direction of Arrival (DoA) estimation in the Compressive Sensing (CS) framework is proposed. In this method, we generate a multi-objective optimization problem by splitting the norm minimization and reconstruction loss minimization parts of the Compressive Sensing algorithm. With the help of the Genetic Algorithm, multiple non-dominated solutions are achieved for the defined multi-objective optimization problem. Among the pareto-frontier solutions, the final solution is obtained with the multiple MCDM methods. Moreover, the performance of the proposed method is compared with the CS-based methods in the literature.Keywords: genetic algorithm, direction of arrival esitmation, multi criteria decision making, compressive sensing
Procedia PDF Downloads 147