Search results for: knee replacement surgery
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1994

Search results for: knee replacement surgery

1904 Arginase Activity and Nitric Oxide Levels in Patients Undergoing Open Heart Surgery with Cardiopulmonary Bypass

Authors: Mehmet Ali Kisaçam, P. Sema Temizer Ozan, Ayşe Doğan, Gonca Ozan, F. Sarper Türker

Abstract:

Cardiovascular disease which is one of the most common health problems worldwide has crucial importance because of its’ morbidity and mortality rates. Nitric oxide synthase and arginase use L-arginine as a substrate and produce nitric oxide (NO), citrulline and urea, ornithine respectively. Endothelial dysfunction is characterized by reduced bioavailability of vasodilator and anti-inflammatory molecule NO. The purpose of the study to assess endothelial function via arginase activity and NO levels in patients undergoing coronary artery bypass grafting (CABG) surgery. The study was conducted on 26 patients (14 male, 12 female) undergoing CABG surgery. Blood samples were collected from the subjects before surgery, after the termination and after 24 hours of the surgery. Arginase activity and NO levels measured in collected samples spectrophotometrically. Arginase activity decreased significantly in subjects after the termination of the surgery compared to before surgery data. 24 hours after the surgery there wasn’t any significance in arginase activity as it compared to before surgery and after the termination of the surgery. On the other hand, NO levels increased significantly in the subject after the termination of the surgery. However there was no significant increase in NO levels after 24 hours of the surgery, but there was an insignificant increase compared to before surgery data. The results indicate that after the termination of the surgery vascular and endothelial function improved and after 24 hours of the surgery arginase activity and NO levels returned to normal.

Keywords: arginase, bypass, cordiopulmonary, nitric oxide

Procedia PDF Downloads 183
1903 Promoting Patients' Adherence to Home-Based Rehabilitation: A Randomised Controlled Trial of a Theory-Driven Mobile Application

Authors: Derwin K. C. Chan, Alfred S. Y. Lee

Abstract:

The integrated model of self-determination theory and the theory of planned behaviour has been successfully applied to explain individuals’ adherence to health behaviours, including behavioural adherence toward rehabilitation. This study was a randomised controlled trial that examined the effectiveness of an mHealth intervention (i.e., mobile application) developed based on this integrated model in promoting treatment adherence of patients of anterior cruciate ligament rupture during their post-surgery home-based rehabilitation period. Subjects were 67 outpatients (aged between 18 and 60) who undertook anterior cruciate ligament (ACL) reconstruction surgery for less than 2 months for this study. Participants were randomly assigned either into the treatment group (who received the smartphone application; N = 32) and control group (who receive standard treatment only; N = 35), and completed psychological measures relating to the theories (e.g., motivations, social cognitive factors, and behavioural adherence) and clinical outcome measures (e.g., subjective knee function (IKDC), laxity (KT-1000), muscle strength (Biodex)) relating to ACL recovery at baseline, 2-month, and 4-month. Generalise estimating equation showed the interaction between group and time was significant on intention was only significant for intention (Wald x² = 5.23, p = .02), that of perceived behavioural control (Wald x² = 3.19, p = .07), behavioural adherence (Wald x² = 3.08, p = .08, and subjective knee evaluation (Wald x² = 2.97, p = .09) were marginally significant. Post-hoc between-subject analysis showed that control group had significant drop of perceived behavioural control (p < .01), subjective norm (p < .01) and intention (p < .01), behavioural adherence (p < .01) from baseline to 4-month, but such pattern was not observed in the treatment group. The treatment group had a significant decrease of behavioural adherence (p < .05) in the 2-month, but such a decrease was not observed in 4-month (p > .05). Although the subjective knee evaluation in both group significantly improved at 2-month and 4-month from the baseline (p < .05), and the improvements in the control group (mean improvement at 4-month = 40.18) were slightly stronger than the treatment group (mean improvement at 4-month = 34.52). In conclusion, the findings showed that the theory driven mobile application ameliorated the decline of treatment intention of home-based rehabilitation. Patients in the treatment group also reported better muscle strength than control group at 4-month follow-up. Overall, the mobile application has shown promises on tackling the problem of orthopaedics outpatients’ non-adherence to medical treatment.

Keywords: self-determination theory, theory of planned behaviour, mobile health, orthopaedic patients

Procedia PDF Downloads 173
1902 Immediate Effect of Augmented Feedback on Jumping Performance of the Athletes with Dynamic Knee Valgus

Authors: Mohamadreza Hatefi, Malihe Hadadnezhad

Abstract:

It is well established that jump-landing-related biomechanical deficiencies, such as dynamic knee valgus (DKV), can be improved by using various forms of feedback; However, the effectiveness of these interventions synchronously on athletes' jumping performance remains unknown. Twenty-one recreational athletes with DKV performed countermovement jump (CMJ) and drop vertical jump (DVJ) tasks before and after feedback intervention while the kinematic, force plate and electromyography data of the lower extremity were synchronously captured. The athletes’ jumping performance was calculated by using the reactive strength index-modified (RSIₘₒ𝒹). The athletes at the post-intervention exhibited significantly less hip adduction and more tibial internal rotation during both CMJ and DVJ tasks and maximum knee flexion just during DVJ task. Moreover, athletes exhibited increased time to take-off and consequently decreased RSIₘₒ𝒹 during DVJ task, but no difference was observed in CMJ task. Feedback immediately improved DKV without disturbing the athletes’ jumping height during both tasks, But athletes exhibited increased time to take-off and consequently decreased RSIₘₒ𝒹 only during DVJ task, which suggests that the results may differ according to the nature of jumping task. Nevertheless, the effectiveness of landing-related biomechanical deficiencies improvement on athletes' jumping performance must be investigated in the long-term as a new movement pattern.

Keywords: reactive strength index, feedback, biomechanics, dynamic knee valgus

Procedia PDF Downloads 77
1901 A Possible Connection Between Taste Change and Zinc Deficiency after Bariatric Surgery: A Literature Review

Authors: Boshra Mozaffar, Iskandar Idris

Abstract:

Taste change is a common complication after Bariatric surgery (BS). However, the cause of this is still not clear. Since zinc is important fortaste perception, zinc deficiency, which is common after BS, may play an important role for taste change after BS. In this review, we aimto collate evidence relating to taste change and zinc deficiencyin relation to BS; effects of zinc replacement on taste perception in general and thereafter discuss the possible role of zinc deficiency to induce taste change after BS. A literature search was conducted, using four electronic bibliographical databases—EMBASE, PubMed, AMED and MEDLINE. We identified all available and relevant articles published before 30th February 2021.In total, 33 studies were included. The total number of participants analysed was N= 3264. We showed that taste change is a frequent complication after BS, especially after Roux-en-Y gastric bypass RYGBP comparing to other types of procedures. Patients' taste sensitivity differs among studies, but the most important decline in taste preference was observed for sweet food. Twelve studies investigating zinc deficiency following BS showed a significant decrease in zinc levels at six months after surgery. Supplementation with 45–50 mg of zinc sulphate was effective in improving taste, except in cancer patients, who showed no improvement in taste following zinc supplementation. Zinc deficiency appears to be associated with taste change after BS. Supplementation with much higher levels of zinc, at 45–50 mg, was effective in taste change treatment for many cases of taste disorder. The currently recommended levels of zinc replacements currently prescribed to patients following BS were not effective for avoiding zinc deficiency after BS—and thus not effective for averting taste change. It is therefore suggested that taste change following BS is closely related to zinc deficiency induced by the surgery.

Keywords: taste change, taste disorder, bariatric surgery, zinc, zinc sulphate or Zn, deficiency, supplementation, and micro-nutrient deficiencies

Procedia PDF Downloads 148
1900 Role of Interlukin-18 in Primary Knee Osteoarthritis: Clinical, Laboratory and Radiological Study

Authors: Ibrahim Khalil Ibrahim, Enas Mohamed Shahine, Abeer Shawky El Hadedy, Emmanuel Kamal Aziz Saba, Ghada Salah Attia Hussein

Abstract:

Osteoarthritis (OA) is a multifactorial disease characterized by a progressive degradation of articular cartilage and is the leading cause of disability in elderly persons. IL-18 contributes to the destruction of cartilage and bone in the disease process of arthritis. The aim of the study was to investigate the role of IL-18 in primary knee OA patients. Serum level of IL-18 was assessed by enzyme-linked immunosorbent assay in 30 primary knee OA patients and compared to 20 age and gender-matched healthy volunteers as a control group. Radiographic severity of OA was assessed by Kellgren and Lawrence (KL) global scale. Pain, stiffness and functional assessment were done using Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). OA patients had significantly higher serum IL-18 level than in control group (420.93 ± 345.4 versus 151.03 ± 144.16 pg/ml, P=0.001). Serum level of IL-18 was positively correlated with KL global scale (P=0.001). There were no statistically significant correlations between serum level of IL-18 and pain, stiffness, function subscales and total WOMAC index scores among the studied patients. In conclusions, IL-18 has a role in the pathogenesis of OA and it is positively correlated with the radiographic damage of OA.

Keywords: Interlukin-18, knee osteoarthritis, primary osteoarthritis, WOMAC scale

Procedia PDF Downloads 346
1899 Effects of High-Intensity Interval Training versus Traditional Rehabilitation Exercises on Functional Outcomes in Patients with Knee Osteoarthritis: A Randomized Controlled Trial

Authors: Ahmed Torad

Abstract:

Background: Knee osteoarthritis (OA) is a prevalent musculoskeletal condition characterized by pain and functional impairment. While various rehabilitation approaches have been employed, the effectiveness of high-intensity interval training (HIIT) compared to traditional rehabilitation exercises remains unclear. Objective: This randomized controlled trial aimed to compare the effects of HIIT and traditional rehabilitation exercises on pain reduction, functional improvement, and quality of life in individuals with knee OA. Methods: A total of 120 participants diagnosed with knee OA were randomly allocated into two groups: the HIIT group (n=60) and the traditional rehabilitation group (n=60). The HIIT group participated in a 12-week supervised program consisting of high-intensity interval exercises, while the traditional rehabilitation group followed a conventional physiotherapy regimen. Outcome measures included visual analog scale (VAS) pain scores, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Short Form-36 Health Survey (SF-36) at baseline and after the intervention period. Results: Both groups showed significant improvements in pain scores, functional outcomes (WOMAC), and quality of life (SF-36) after 12 weeks of intervention. However, the HIIT group demonstrated superior pain reduction (p<0.001), functional improvement (p<0.001), and physical health-related quality of life (p=0.002) compared to the traditional rehabilitation group. No significant differences were observed in mental health-related quality of life between the two groups. Conclusion: High-intensity interval training appears to be a more effective rehabilitation approach than traditional exercises for individuals with knee osteoarthritis, resulting in greater pain reduction, improved function, and enhanced physical health-related quality of life. These findings suggest that HIIT may represent a promising intervention strategy for managing knee OA and enhancing the overall well-being of affected individuals.

Keywords: knee osteoarthritis, high-intensity interval training, traditional rehabilitation exercises, randomized controlled trial, pain reduction, functional improvement, quality of life

Procedia PDF Downloads 36
1898 Evaluation of Reinforced Concrete Beam-Column Knee Joints Performance: Numerical and Experimental Comparison

Authors: B. S. Abdelwahed, B. B. Belkassem

Abstract:

Beam-column joints are a critical part in reinforced concrete RC frames designed for inelastic response to several external loads. Investigating the behaviour of the exterior RC beam-column joints has attracted many researchers in the past decades due to its critical influence on the overall behaviour of RC moment-resisting frames subjected to lateral loads. One of the most critical zones in moment-resistant frames is the knee joints because of restraints associated with providing limited anchorage length to the beam and column longitudinal reinforcement in it and consequentially causes a lot of damage in such building frames. Previous numerical simulations focussed mainly on the exterior and interior joints, for knee joint further work is still needed to investigate its behaviour and discuss its affecting parameters. Structural response for an RC knee beam-column joint is performed in this study using LS-DYNA. Three-dimensional finite element (FE) models of an RC knee beam-column joint are described and verified with experimental results available in literature; this is followed by a parametric study to investigate the influence of the concrete compressive strength, the presence of lateral beams and increasing beam reinforcement ratio. It is shown that the concrete compressive strength has a significant effect on shear capacity, load-deflection characteristics and failure modes of an RC knee beam-column joints but to a certain limit, the presence of lateral beams increased the joint confinement and reduced the rate of concrete degradation in the joint after reaching ultimate joint capacity, added to that an increase in the maximum load resistance. Increasing beam reinforcement ratio is found to improve the flexural resistance of the anchored beam bars and increase the joint maximum load resistance.

Keywords: beam reinforcement ratio, joint confinement, numerical simulation, reinforced concrete beam-column joints, structural performance

Procedia PDF Downloads 433
1897 Tibial Hemimelia Type VIIa: A Case Report

Authors: M. Medrano, M. D. M. S., L. Younes, M. D.

Abstract:

Introduction: Incidence of tibial hemimelia is 1:1,000,000. Due to pre-existing case studies and literature, there is now a better understanding of the genetics, etiology and pathoanatomy of tibial hemimelia, but an underlying cause is generally unknown. This presentation aims to discuss a rare, congenital lower limb deficiency observed in a patient in order to identify potential prenatal risk factors and future considerations for the patient’s well-being. Observation: A newborn female child, born full term via spontaneous vaginal delivery after induction of labor to unaffected and non-consanguineous parents. The prenatal course was notable for limited and disjointed prenatal care as well as maternal tobacco and marijuana use, anemia of pregnancy, and inadequate weight gain. Prenatal imaging showed lower extremity deformity with the inability to visualize tibia and bilateral clubfeet in the setting of Intrauterine Growth Restriction (IUGR). The patient presented with right equino varus deformity of the foot and right knee joint deformity. Radiological imaging showed the absence of the right tibia and varus angulation of the right foot with dislocation of the tibiotalar joint. Normal femur with lateral and mild anterior displacement of a wide fibula (Weber Type VIIa). Due to the absence of the patient’s tibia and knee extensor mechanism, the patient was not a candidate for reconstructive surgery and ultimately underwent successful right knee disarticulation. Discussion and Conclusion: By utilizing a retrospective chart review of this case, possible risk factors in prenatal care may be identified and add to existing knowledge on etiology. Hopefully, a cause can be clearly identified in the future and, thus, addressed in the prenatal period. In addition, we can investigate the patient’s well-being and adjustment post-operatively to support outpatient management of an uncommon anomaly.

Keywords: Tibial hemimelia, prenatal care, pediatric orthopedics, congenital deformity

Procedia PDF Downloads 132
1896 Properties of Triadic Concrete Containing Rice Husk Ash and Wood Waste Ash as Partial Cement Replacement

Authors: Abdul Rahman Mohd. Sam, Olukotun Nathaniel, Dunu Williams

Abstract:

Concrete is one of the most popular materials used in construction industry. However, one of the setbacks is that concrete can degrade with time upon exposure to an aggressive environment that leads to decrease in strength. Thus, research works and innovative ways are needed to enhance the strength and durability of concrete. This work tries to look into the potential use of rice husk ash (RHA) and wood waste ash (WWA) as cement replacement material. These are waste materials that may not only enhance the properties of concrete but also can serves as a viable method of disposal of waste for sustainability. In addition, a substantial replacement of Ordinary Portland Cement (OPC) with these pozzolans will mean reduction in CO₂ emissions and high energy requirement associated with the production of OPC. This study is aimed at assessing the properties of triadic concrete produced using RHA and WWA as a partial replacement of cement. The effects of partial replacement of OPC with 10% RHA and 5% WWA on compressive and tensile strength of concrete among other properties were investigated. Concrete was produced with nominal mix of 1:2:4 and 0.55 water-cement ratio, prepared, cured and subjected to compressive and tensile strength test at 3, 7, 14, 28 and 90days. The experimental data demonstrate that concrete containing RHA and WWA produced lighter weight in comparison with OPC sample. Results also show that combination of RHA and WWA help to prolong the initial and final setting time by about 10-30% compared to the control sample. Furthermore, compressive strength was increased by 15-30% with 10% RHA and 5% WWA replacement, respectively above the control, RHA and WWA samples. Tensile strength test at the ages of 3, 7, 14, 28 and 90 days reveals that a replacement of 15% RHA and 5% WWA produced samples with the highest tensile capacity compared to the control samples. Thus, it can be concluded that RHA and WWA can be used as partial cement replacement materials in concrete.

Keywords: concrete, rice husk ash, wood waste ash, ordinary Portland cement, compressive strength, tensile strength

Procedia PDF Downloads 234
1895 Equity Investment Restrictions and Pension Replacement Rates in Nigeria: A Ruin-Risk Analysis

Authors: Uche A. Ibekwe

Abstract:

Pension funds are pooled assets which are established to provide income for retirees. The funds are usually regulated to check excessive risk taking by fund managers. In Nigeria, the current defined contribution (DC) pension scheme appears to contain some overly stringent restrictions which might be hampering its successful implementation. Notable among these restrictions is the 25 percent maximum limit on investment in ordinary shares of quoted companies. This paper examines the extent to which these restrictions affect pension replacement rates at retirement. The study made use of both simulated and historical asset return distributions using mean-variance, regression analysis and ruin-risk analyses, the study found that the current equity investment restriction policy in Nigeria reduces replacement rates at retirement.

Keywords: equity investment, replacement rates, restrictions, ruin-risk

Procedia PDF Downloads 318
1894 Design of Soil Replacement under Axial Centric Load Isolated Footing by Limit State Method

Authors: Emad A. M. Osman, Ahmed M. Abu-Bakr

Abstract:

Compacted granular fill under shallow foundation is one of the oldest, cheapest, and easiest techniques to improve the soil characteristics to increase the bearing capacity and decrease settlement under footing. There are three main factors affecting the design of soil replacement to gain these advantages. These factors are the type of replaced soil, characteristics, and thickness. The first two factors can be easily determined by laboratory and field control. This paper emphasizes on how to determine the thickness accurately for footing under centric axial load by limit state design method. The advantages of the method are the way of determining the thickness (independent of experience) and it takes into account the replaced and original or underneath soil characteristics and reaches the goals of replaced soils economically.

Keywords: design of soil replacement, LSD method, soil replacement, soil improvement

Procedia PDF Downloads 319
1893 Reliability of 2D Motion Analysis System for Sagittal Plane Lower Limb Kinematics during Running

Authors: Seyed Hamed Mousavi, Juha M. Hijmans, Reza Rajabi, Ron Diercks, Johannes Zwerver, Henk van der Worp

Abstract:

Introduction: Running is one of the most popular sports activity among people. Improper sagittal plane ankle, knee and hip kinematics are considered to be associated with the increase of injury risk in runners. Motion assessing smart-phone applications are increasingly used to measure kinematics both in the field and laboratory setting, as they are cheaper, more portable, accessible, and easier to use relative to 3D motion analysis system. The aims of this study are 1) to compare the results of 3D gait analysis system and CE; 2) to evaluate the test-retest and intra-rater reliability of coach’s eye (CE) app for the sagittal plane hip, knee, and ankle angles in the touchdown and toe-off while running. Method: Twenty subjects participated in this study. Sixteen reflective markers and cluster markers were attached to the subject’s body. Subjects were asked to run at a self-selected speed on a treadmill. Twenty-five seconds of running were collected for analyzing kinematics of interest. To measure sagittal plane hip, knee and ankle joint angles at touchdown (TD) and toe off (TO), the mean of first ten acceptable consecutive strides was calculated for each angle. A smartphone (Samsung Note5, android) was placed on the right side of the subject so that whole body was simultaneously filmed with 3D gait system during running. All subjects repeated the task with the same running speed after a short interval of 5 minutes in between. The CE app, installed on the smartphone, was used to measure the sagittal plane hip, knee and ankle joint angles at touchdown and toe off the stance phase. Results: Intraclass correlation coefficient (ICC) was used to assess test-retest and intra-rater reliability. To analyze the agreement between 3D and 2D outcomes, the Bland and Altman plot was used. The values of ICC were for Ankle at TD (TRR=0.8,IRR=0.94), ankle at TO (TRR=0.9,IRR=0.97), knee at TD (TRR=0.78,IRR=0.98), knee at TO (TRR=0.9,IRR=0.96), hip at TD (TRR=0.75,IRR=0.97), hip at TO (TRR=0.87,IRR=0.98). The Bland and Altman plots displaying a mean difference (MD) and ±2 standard deviation of MD (2SDMD) of 3D and 2D outcomes were for Ankle at TD (MD=3.71,+2SDMD=8.19, -2SDMD=-0.77), ankle at TO (MD=-1.27, +2SDMD=6.22, -2SDMD=-8.76), knee at TD (MD=1.48, +2SDMD=8.21, -2SDMD=-5.25), knee at TO (MD=-6.63, +2SDMD=3.94, -2SDMD=-17.19), hip at TD (MD=1.51, +2SDMD=9.05, -2SDMD=-6.03), hip at TO (MD=-0.18, +2SDMD=12.22, -2SDMD=-12.59). Discussion: The ability that the measurements are accurately reproduced is valuable in the performance and clinical assessment of outcomes of joint angles. The results of this study showed that the intra-rater and test-retest reliability of CE app for all kinematics measured are excellent (ICC ≥ 0.75). The Bland and Altman plots display that there are high differences of values for ankle at TD and knee at TO. Measuring ankle at TD by 2D gait analysis depends on the plane of movement. Since ankle at TD mostly occurs in the none-sagittal plane, the measurements can be different as foot progression angle at TD increases during running. The difference in values of the knee at TD can depend on how 3D and the rater detect the TO during the stance phase of running.

Keywords: reliability, running, sagittal plane, two dimensional

Procedia PDF Downloads 168
1892 Percentage Contribution of Lower Limb Moments to Vertical Ground Reaction Force in Normal Walking

Authors: Salam M. Elhafez, Ahmed A. Ashour, Naglaa M. Elhafez, Ghada M. Elhafez, Azza M. Abdelmohsen

Abstract:

Patients suffering from gait disturbances are referred by having muscle group dysfunctions. There is a need for more studies investigating the contribution of muscle moments of the lower limb to the vertical ground reaction force using 3D gait analysis system. The purpose of this study was to investigate how the hip, knee and ankle moments in the sagittal plane contribute to the vertical ground reaction force in healthy subjects during normal speed of walking. Forty healthy male individuals volunteered to participate in this study. They were filmed using six high speed (120 Hz) Pro-Reflex Infrared cameras (Qualisys) while walking on an AMTI force platform. The data collected were the percentage contribution of the moments of the hip, knee and ankle joints in the sagittal plane at the instant of occurrence of the first peak, second peak, and the trough of the vertical ground reaction force. The results revealed that at the first peak of the ground reaction force (loading response), the highest contribution was generated from the knee extension moment, followed by the hip extension moment. Knee flexion and ankle plantar flexion moments produced high contribution to the trough of the ground reaction force (midstance) with approximately equal values. The second peak of the ground reaction force was mainly produced by the ankle plantar flexion moment. Conclusion: Hip and knee flexion and extension moments and ankle plantar flexion moment play important roles in the supporting phase of normal walking.

Keywords: gait analysis, ground reaction force, moment contribution, normal walking

Procedia PDF Downloads 347
1891 Comparison between Infusion Pumps: Fentanyl/Ketamine and Fentanyl/Paracetamol in Pain Control Following Tight and Leg Surgeries

Authors: Maryam Panahi

Abstract:

Background: Adjuvants such as ketamine, promethazine, and paracetamol could bring up patient's satisfaction and control the harmful effects of opioids besides lessening their needed doses, as seen by the fentanyl/paracetamol and fentanyl/ketamine combination before. The current study is headed to compare paracetamol and ketamine, in addition to fentanyl, applied by infusion pumps in order to pain relief following major surgery. Materials and Methods: Through a double-blinded, randomized clinical trial, patients between18 and 65 with elective surgery for tight or leg fractures with ASA Class 1 and 2 referred to a university hospital in Arak, a town in the central region of Iran, were recruited and used infusion pump for their postoperative pain control. The participants were divided into cases and controls regarding using ketamine/fentanyl (KF) or paracetamol/fentanyl (PF) infusion pumps. Results: The mean pain score was a total of 3.87, with the highest value in KF (5.06) and the lowest in PF (4.50) immediately after finishing the surgery and getting conscious when started using an infusion pump. There was no statistical difference between the groups in this regard. Concerning the side effects of the applied medications, blood pressure and heart rate had no differences comparing the groups. Conclusion: This study showed that paracetamol used in infusion pumps could be brilliant in pain control after major surgeries like those done in lower extremities and joint replacement while lessening opioid use. Although paracetamol was more effective than ketamine in the current trial, more qualified studies at bigger sizes and in other fields of surgery besides orthopedic ones would be useful to support the effects if applicable

Keywords: infusion pump, Ketamine, Paracetamol, pain

Procedia PDF Downloads 32
1890 Antagonist Coactivation in Athletes Following Anterior Cruciate Ligament Reconstruction

Authors: Milad Pirali, Sohrab Keyhani, Mohhamad Ali Sanjari, Ali Ashraf Jamshidi

Abstract:

Purpose: The effect of hamstring antagonist activity on the knee extensors torque of the Anterior Cruciate Ligament reconstruction (ACLR) is not clear and persistent muscle weakness is common after ACLR. Hamstring activation when acting as antagonist is considered very important for knee strengths. Therefore the purpose of this study was to examine hamstring antagonist coactivation during maximal effort of the isokinetic knee extension in ACLR athletes with hamstring autograft. Materials and Methods: We enrolled 20 professional athletes who underwent primary ACLR (hamstring tendon autograft)with 6-24 months postoperative and 20 healthy subjects as control group. Each subjects performed maximal effort isokinetic knee extension and flexion in 60/˚ s and 180/˚ s velocities for the involved and uninvolved limb. Synchronously, surface electromyography (EMG) was recorded of vastus medialis (VM), vastus lateralis (VL), rectus femoris (RF) and biceps femoris (BF). The antagonist integrated EMG (IEMG) values were normalized to the IEMG of the same muscle during maximal isokinetic eccentric effort at the same velocities and ROM. Results: A one-way analysis of variance designs shows significantly greater IEMG coactivation of hamstring and decreased activation of Vm in ACLR when compared to uninvolved and control group leg in 60/˚ s and 180/˚ s velocities. Likewise peak torque to body weight was decreased in ACLR compared to uninvolved and control group during knee extension in both velocities (p < 0.05). Conclusions: Decreased extensors moment caused by decreased quadriceps inhibition and increased hamstring coactivation. In addition, these result indicated to decrease of motor unit recruitment in the VM (as a kinesiologicmonitore of the knee). It is appearing that strengthening of the quadriceps to be an important for rehabilitation program after ACLR for preparation in athletes endeavors. Therefore, we suggest that having more emphasis and focus on quadriceps strength and less emphasis on hamstring following ACLR.

Keywords: ACLR-coactivation, dynamometry, electromyography, isokinetic

Procedia PDF Downloads 224
1889 The Outcome of Early Balance Exercises and Agility Training in Sports Rehabilitation for Patients Post Anterior Cruciate Ligament (ACL) Reconstruction

Authors: S. M. A. Ismail, M. I. Ibrahim, H. Masdar, F. M. Effendi, M. F. Suhaimi, A. Suun

Abstract:

Introduction: It is generally known that the rehabilitation process is as important as the reconstruction surgery. Several literature has focused on how early the rehabilitation modalities can be initiated after the surgery to ensure a safe return of patients to sports or at least regaining the pre-injury level of function following an ACL reconstruction. Objectives: The main objective is to study and evaluate the outcome of early balance exercises and agility training in sports rehabilitation for patients post ACL reconstruction. To compare between early balance exercises and agility training as intervention and control. (material or non-material). All of them were recruited for material exercise (balance exercises and agility training with strengthening) and strengthening only rehabilitation protocol (non-material). Followed the prospective intervention trial. Materials and Methods: Post-operative ACL reconstruction patients performed in Selayang and Sg Buloh Hospitals from 2012 to 2014 were selected for this study. They were taken from Malaysian Knee Ligament Registry (MKLR) and all patients had single bundle reconstruction with autograft hamstring tendon (semitendinosus and gracilis). ACL injury from any type of sports were included. Subjects performed various type of physical activity for rehabilitation in every 18 week for a different type of rehab activity. All subject attended all 18 sessions of rehabilitation exercises and evaluation was done during the first, 9th and 18th session. Evaluation format were based on clinical assessment (anterior drawer, Lachmann, pivot shift, laxity with rolimeter, the end point and thigh circumference) and scoring (Lysholm Knee scoring and Tegner Activity Level scale). Rehabilitation protocol initiated from 24 week after the surgery. Evaluation format were based on clinical assessment (anterior drawer, Lachmann, pivot shift, laxity with rolimeter, the end point and thigh circumference) and scoring (Lysholm Knee scoring and Tegner Activity Level scale). Results and Discussion: 100 patients were selected of which 94 patients are male and 6 female. Age range is 18 to 54 year with the average of 28 years old for included 100 patients. All patients are evaluated after 24 week after the surgery. 50 of them were recruited for material exercise (balance exercises and agility training with strengthening) and 50 for strengthening only rehabilitation protocol (non-material). Demographically showed 85% suffering sports injury mainly from futsal and football. 39 % of them have abnormal BMI (26 – 38) and involving of the left knee. 100% of patient had the basic radiographic x-ray of knee and 98% had MRI. All patients had negative anterior drawer’s, Lachman test and Pivot shift test during the post ACL reconstruction after the complete rehabilitation. There was 95 subject sustained grade I injury, 5 of grade II and 0 of grade III with 90% of them had soft end-point. Overall they scored badly on presentation with 53% of Lysholm score (poor) and Tegner activity score level 3/10. After completing 9 weeks of exercises, of material group 90% had grade I laxity, 75% with firm end-point, Lysholm score 71% (fair) and Tegner activity level 5/10 comparing non-material group who had 62% of grade I laxity , 54% of firm end-point, Lyhslom score 62 % (poor) and Tegner activity level 4/10. After completed 18 weeks of exercises, of material group maintained 90% grade I laxity with 100 % with firm end-point, Lysholm score increase 91% (excellent) and Tegner activity level 7/10 comparing non-material group who had 69% of grade I laxity but maintained 54% of firm end-point, Lysholm score 76% (fair) and Tegner activity level 5/10. These showed the improvement were achieved fast on material group who have achieved satisfactory level after 9th cycle of exercises 75% (15/20) comparing non-material group who only achieved 54% (7/13) after completed 18th session. Most of them were grade I. These concepts are consolidated into our approach to prepare patients for return to play including field testing and maintenance training. Conclusions: The basic approach in ACL rehabilitation is to ensure return to sports at post-operative 6 month. Grade I and II laxity has favourable and early satisfactory outcome base on clinical assessment and Lysholm and Tegner scoring point. Reduction of laxity grading indicates satisfactory outcome. Firm end-point showed the adequacy of rehabilitation before starting previous sports game. Material exercise (balance exercises and agility training with strengthening) were beneficial and reliable in order to achieve favourable and early satisfactory outcome comparing strengthening only (non-material).We have identified that rehabilitation protocol varies between different patients. Therefore future post ACL reconstruction rehabilitation guidelines should look into focusing on rehabilitation techniques instead of time.

Keywords: post anterior cruciate ligament (ACL) reconstruction, single bundle, hamstring tendon, sports rehabilitation, balance exercises, agility balance

Procedia PDF Downloads 231
1888 Modern Cardiac Surgical Outcomes in Nonagenarians: A Multicentre Retrospective Observational Study

Authors: Laurence Weinberg, Dominic Walpole, Dong-Kyu Lee, Michael D’Silva, Jian W. Chan, Lachlan F. Miles, Bradley Carp, Adam Wells, Tuck S. Ngun, Siven Seevanayagam, George Matalanis, Ziauddin Ansari, Rinaldo Bellomo, Michael Yii

Abstract:

Background: There have been multiple recent advancements in the selection, optimization and management of cardiac surgical patients. However, there is limited data regarding the outcomes of nonagenarians undergoing cardiac surgery, despite this vulnerable cohort increasingly receiving these interventions. This study describes the patient characteristics, management and outcomes of a group of nonagenarians undergoing cardiac surgery in the context of contemporary peri-operative care. Methods: A retrospective observational study was conducted of patients 90 to 99 years of age (i.e., nonagenarians) who had undergone cardiac surgery requiring a classic median sternotomy (i.e., open-heart surgery). All operative indications were included. Patients who underwent minimally invasive surgery, transcatheter aortic valve implantation and thoracic aorta surgery were excluded. Data were collected from four hospitals in Victoria, Australia, over an 8-year period (January 2012 – December 2019). The primary objective was to assess six-month mortality in nonagenarians undergoing open-heart surgery and to evaluate the incidence and severity of postoperative complications using the Clavien-Dindo classification system. The secondary objective was to provide a detailed description of the characteristics and peri-operative management of this group. Results: A total of 12,358 adult patients underwent cardiac surgery at the study centers during the observation period, of whom 18 nonagenarians (0.15%) fulfilled the inclusion criteria. The median (IQR) [min-max] age was 91 years (90.0:91.8) [90-94] and 14 patients (78%) were men. Cardiovascular comorbidities, polypharmacy and frailty, were common. The median (IQR) predicted in-hospital mortality by EuroSCORE II was 6.1% (4.1-14.5). All patients were optimized preoperatively by a multidisciplinary team of surgeons, cardiologists, geriatricians and anesthetists. All index surgeries were performed on cardiopulmonary bypass. Isolated coronary artery bypass grafting (CABG) and CABG with aortic valve replacement were the most common surgeries being performed in four and five patients, respectively. Half the study group underwent surgery involving two or more major procedures (e.g. CABG and valve replacement). Surgery was undertaken emergently in 44% of patients. All patients except one experienced at least one postoperative complication. The most common complications were acute kidney injury (72%), new atrial fibrillation (44%) and delirium (39%). The highest Clavien-Dindo complication grade was IIIb occurring once each in three patients. Clavien-Dindo grade IIIa complications occurred in only one patient. The median (IQR) postoperative length of stay was 11.6 days (9.8:17.6). One patient was discharged home and all others to an inpatient rehabilitation facility. Three patients had an unplanned readmission within 30 days of discharge. All patients had follow-up to at least six months after surgery and mortality over this period was zero. The median (IQR) duration of follow-up was 11.3 months (6.0:26.4) and there were no cases of mortality observed within the available follow-up records. Conclusion: In this group of nonagenarians undergoing cardiac surgery, postoperative six-month mortality was zero. Complications were common but generally of low severity. These findings support carefully selected nonagenarian patients being offered cardiac surgery in the context of contemporary, multidisciplinary perioperative care. Further, studies are needed to assess longer-term mortality and functional and quality of life outcomes in this vulnerable surgical cohort.

Keywords: cardiac surgery, mortality, nonagenarians, postoperative complications

Procedia PDF Downloads 92
1887 Correlation between Dynamic Knee Valgus with Isometric Hip External Rotators Strength during Single Leg Landing

Authors: Ahmed Fawzy, Khaled Ayad, Gh. M. Koura, W. Reda

Abstract:

The excessive frontal plane motion of the lower extremity during sports activities is thought to be a contributing factor to many traumatic and overuse injuries of the knee joint, little is known about the biomechanical factors that contribute to this loading pattern. Objectives: The purpose of this study was to investigate if there is a relationship between hip external rotators isometric strength and the value of frontal plane projection angle (FPPA) during single leg landing tasks in normal male subjects. Methods: One hundred (male) subjects free from lower extremity injuries for at least six months ago participated in this study. Their mean age was (23.25 ± 2.88) years, mean weight was (74.76 ± 13.54) (Kg), mean height was (174.23 ± 6.56) (Cm). The knee frontal plane projection angle was measured by digital video camera using single leg landing task. Hip external rotators isometric strength were assessed by portable hand held dynamometer. Muscle strength had been normalized to the body weight to obtain more accurate measurements. Results: The results demonstrated that there was no significant relationship between hip external rotators isometric strength and the value of FPPA during single leg landing tasks in normal male subjects. Conclusion: It can be concluded that there is no relationship between hip external rotators isometric strength and the value of FPPA during functional activities in normal male subjects.

Keywords: 2-dimensional motion analysis, hip strength, kinematics, knee injuries

Procedia PDF Downloads 201
1886 Effect of Different Knee-Joint Positions on Passive Stiffness of Medial Gastrocnemius Muscle and Aponeuroses during Passive Ankle Motion

Authors: Xiyao Shan, Pavlos Evangelidis, Adam Kositsky, Naoki Ikeda, Yasuo Kawakami

Abstract:

The human triceps surae (two bi-articular gastrocnemii and one mono-articular soleus) have aponeuroses in the posterior and anterior aspects of each muscle, where the anterior aponeuroses of the gastrocnemii adjoin the posterior aponeurosis of the soleus, possibly contributing to the intermuscular force transmission between gastrocnemii and soleus. Since the mechanical behavior of these aponeuroses at different knee- and ankle-joint positions remains unclear, the purpose of this study was to clarify this through observations of the localized changes in passive stiffness of the posterior aponeuroses, muscle belly and adjoining aponeuroses of the medial gastrocnemius (MG) induced by different knee and ankle angles. Eleven healthy young males (25 ± 2 yr, 176.7 ± 4.7 cm, 71.1 ± 11.1 kg) participated in this study. Each subject took either a prone position on an isokinetic dynamometer while the knee joint was fully extended (K180) or a kneeling position while the knee joint was 90° flexed (K90), in a randomized and counterbalanced order. The ankle joint was then passively moved through a 50° range of motion (ROM) by the dynamometer from 30° of plantar flexion (PF) to 20° of dorsiflexion (DF) at 2°/s and the ultrasound shear-wave velocity was measured to obtain shear moduli of the posterior aponeurosis, MG belly, and adjoining aponeuroses. The main findings were: 1) shear modulus in K180 was significantly higher (p < 0.05) than K90 for the posterior aponeurosis (across all ankle angles, 10.2 ± 5.7 kPa-59.4 ± 28.7 kPa vs. 5.4 ± 2.2 kPa-11.6 ± 4.1 kPa), MG belly (from PF10° to DF20°, 9.7 ± 2.2 kPa-53.6 ± 18.6 kPa vs. 8.0 ± 2.7 kPa-9.5 ± 3.7 kPa), and adjoining aponeuroses (across all ankle angles, 17.3 ± 7.8 kPa-80 ± 25.7 kPa vs. 12.2 ± 4.5 kPa-52.4 ± 23.0 kPa); 2) shear modulus of the posterior aponeuroses significantly increased (p < 0.05) from PF10° to PF20° in K180, while shear modulus of MG belly significantly increased (p < 0.05) from 0° to PF20° only in K180 and shear modulus of adjoining aponeuroses significantly increased (p < 0.05) across the whole ROM of ankle both in K180 and K90. These results suggest that different knee-joint positions can affect not only the bi-articular gastrocnemius but also influence the mechanical behavior of aponeuroses. In addition, compared to the gradual stiffening of the adjoining aponeuroses across the whole ROM of ankle, the posterior aponeurosis became slack in the plantar flexed positions and then was stiffened gradually as the knee was fully extended. This suggests distinct stiffening for the posterior and adjoining aponeuroses which is joint position-dependent.

Keywords: aponeurosis, plantar flexion and dorsiflexion, shear modulus, shear wave elastography

Procedia PDF Downloads 163
1885 Prophylactic Replacement of Voice Prosthesis: A Study to Predict Prosthesis Lifetime

Authors: Anne Heirman, Vincent van der Noort, Rob van Son, Marije Petersen, Lisette van der Molen, Gyorgy Halmos, Richard Dirven, Michiel van den Brekel

Abstract:

Objective: Voice prosthesis leakage significantly impacts laryngectomies patients' quality of life, causing insecurity and frequent unplanned hospital visits and costs. In this study, the concept of prophylactic voice prosthesis replacement was explored to prevent leakages. Study Design: A retrospective cohort study. Setting: Tertiary hospital. Methods: Device lifetimes and voice prosthesis replacements of a retrospective cohort, including all patients with laryngectomies between 2000 and 2012 in the Netherlands Cancer Institute, were used to calculate the number of needed voice prostheses per patient per year when preventing 70% of the leakages by prophylactic replacement. Various strategies for the timing of prophylactic replacement were considered: Adaptive strategies based on the individual patient’s history of replacement and fixed strategies based on the results of patients with similar voice prosthesis or treatment characteristics. Results: Patients used a median of 3.4 voice prostheses per year (range 0.1-48.1). We found a high inter-and intrapatient variability in device lifetime. When applying prophylactic replacement, this would become a median of 9.4 voice prostheses per year, which means replacement every 38 days, implying more than six additional voice prostheses per patient per year. The individual adaptive model showed that preventing 70% of the leakages was impossible for most patients, and only a median of 25% can be prevented. Monte-Carlo simulations showed that prophylactic replacement is not feasible due to the high Coefficient of Variation (Standard Deviation/Mean) in device lifetime. Conclusion: Based on our simulations, prophylactic replacement of voice prostheses is not feasible due to high inter-and intrapatient variation in device lifetime.

Keywords: voice prosthesis, voice rehabilitation, total laryngectomy, prosthetic leakage, device lifetime

Procedia PDF Downloads 101
1884 Evaluation of Fresh, Strength and Durability Properties of Self-Compacting Concrete Incorporating Bagasse Ash

Authors: Abdul Haseeb Wani, Shruti Sharma, Rafat Siddique

Abstract:

Self-compacting concrete is an engineered concrete that flows and de-airs without additional energy input. Such concrete requires a high slump which can be achieved by the addition of superplasticizers to the concrete mix. In the present work, bagasse ash is utilised as a replacement of cement in self-compacting concrete. This serves the purpose of both land disposal and environmental concerns related to the disposal of bagasse ash. Further, an experimental program was carried out to study the fresh, strength, and durability properties of self-compacting concrete made with bagasse ash. The mixes were prepared with four percentages (0, 5, 10 and 15) of bagasse ash as partial replacement of cement. Properties investigated were; Slump-flow, V-funnel and L-box, Compressive strength, Splitting tensile strength, Chloride-ion penetration resistance and Water absorption. Compressive and splitting tensile strength tests were conducted at the age of 7 and 28 days. Rapid chloride-ion permeability test was carried at the age of 28 days and water absorption test was carried out at the age of 7 days after initial curing of 28 days. Test results showed that there is an increase in the compressive strength and splitting tensile strength of the concrete specimens having up to 10% replacement level, however, there is a slight decrease at 15% level of replacement. Resistance to chloride-ion penetration of the specimens increased as the percentage of replacement was increased. The charge passed in all the specimens containing bagasse ash was lower than that of the specimen without bagasse ash. Water absorption of the specimens decreased up to 10% replacement level and increased at 15% level of replacement. Hence, it can be concluded that optimum level of replacement of cement with bagasse ash in self-compacting concrete comes out to be 10%; at which the self-compacting concrete has satisfactory flow characteristics (as per the European guidelines), improved compressive and splitting tensile strength and better durability properties as compared to the control mix.

Keywords: bagasse ash, compressive strength, self-compacting concrete, splitting tensile strength

Procedia PDF Downloads 326
1883 Evaluating the Impact of Replacement Policies on the Cache Performance and Energy Consumption in Different Multicore Embedded Systems

Authors: Sajjad Rostami-Sani, Mojtaba Valinataj, Amir-Hossein Khojir-Angasi

Abstract:

The cache has an important role in the reduction of access delay between a processor and memory in high-performance embedded systems. In these systems, the energy consumption is one of the most important concerns, and it will become more important with smaller processor feature sizes and higher frequencies. Meanwhile, the cache system dissipates a significant portion of energy compared to the other components of a processor. There are some elements that can affect the energy consumption of the cache such as replacement policy and degree of associativity. Due to these points, it can be inferred that selecting an appropriate configuration for the cache is a crucial part of designing a system. In this paper, we investigate the effect of different cache replacement policies on both cache’s performance and energy consumption. Furthermore, the impact of different Instruction Set Architectures (ISAs) on cache’s performance and energy consumption has been investigated.

Keywords: energy consumption, replacement policy, instruction set architecture, multicore processor

Procedia PDF Downloads 117
1882 Replacement of the Distorted Dentition of the Cone Beam Computed Tomography Scan Models for Orthognathic Surgery Planning

Authors: T. Almutairi, K. Naudi, N. Nairn, X. Ju, B. Eng, J. Whitters, A. Ayoub

Abstract:

Purpose: At present Cone Beam Computed Tomography (CBCT) imaging does not record dental morphology accurately due to the scattering produced by metallic restorations and the reported magnification. The aim of this pilot study is the development and validation of a new method for the replacement of the distorted dentition of CBCT scans with the dental image captured by the digital intraoral camera. Materials and Method: Six dried skulls with orthodontics brackets on the teeth were used in this study. Three intra-oral markers made of dental stone were constructed which were attached to orthodontics brackets. The skulls were CBCT scanned, and occlusal surface was captured using TRIOS® 3D intraoral scanner. Marker based and surface based registrations were performed to fuse the digital intra-oral scan(IOS) into the CBCT models. This produced a new composite digital model of the skull and dentition. The skulls were scanned again using the commercially accurate Laser Faro® arm to produce the 'gold standard' model for the assessment of the accuracy of the developed method. The accuracy of the method was assessed by measuring the distance between the occlusal surfaces of the new composite model and the 'gold standard' 3D model of the skull and teeth. The procedure was repeated a week apart to measure the reproducibility of the method. Results: The results showed no statistically significant difference between the measurements on the first and second occasions. The absolute mean distance between the new composite model and the laser model ranged between 0.11 mm to 0.20 mm. Conclusion: The dentition of the CBCT can be accurately replaced with the dental image captured by the intra-oral scanner to create a composite model. This method will improve the accuracy of orthognathic surgical prediction planning, with the final goal of the fabrication of a physical occlusal wafer without to guide orthognathic surgery and eliminate the need for dental impression.

Keywords: orthognathic surgery, superimposition, models, cone beam computed tomography

Procedia PDF Downloads 165
1881 Design of Ultra-Light and Ultra-Stiff Lattice Structure for Performance Improvement of Robotic Knee Exoskeleton

Authors: Bing Chen, Xiang Ni, Eric Li

Abstract:

With the population ageing, the number of patients suffering from chronic diseases is increasing, among which stroke is a high incidence for the elderly. In addition, there is a gradual increase in the number of patients with orthopedic or neurological conditions such as spinal cord injuries, nerve injuries, and other knee injuries. These diseases are chronic, with high recurrence and complications, and normal walking is difficult for such patients. Nowadays, robotic knee exoskeletons have been developed for individuals with knee impairments. However, the currently available robotic knee exoskeletons are generally developed with heavyweight, which makes the patients uncomfortable to wear, prone to wearing fatigue, shortening the wearing time, and reducing the efficiency of exoskeletons. Some lightweight materials, such as carbon fiber and titanium alloy, have been used for the development of robotic knee exoskeletons. However, this increases the cost of the exoskeletons. This paper illustrates the design of a new ultra-light and ultra-stiff truss type of lattice structure. The lattice structures are arranged in a fan shape, which can fit well with circular arc surfaces such as circular holes, and it can be utilized in the design of rods, brackets, and other parts of a robotic knee exoskeleton to reduce the weight. The metamaterial is formed by continuous arrangement and combination of small truss structure unit cells, which changes the diameter of the pillar section, geometrical size, and relative density of each unit cell. It can be made quickly through additive manufacturing techniques such as metal 3D printing. The unit cell of the truss structure is small, and the machined parts of the robotic knee exoskeleton, such as connectors, rods, and bearing brackets, can be filled and replaced by gradient arrangement and non-uniform distribution. Under the condition of satisfying the mechanical properties of the robotic knee exoskeleton, the weight of the exoskeleton is reduced, and hence, the patient’s wearing fatigue is relaxed, and the wearing time of the exoskeleton is increased. Thus, the efficiency and wearing comfort, and safety of the exoskeleton can be improved. In this paper, a brief description of the hardware design of the prototype of the robotic knee exoskeleton is first presented. Next, the design of the ultra-light and ultra-stiff truss type of lattice structures is proposed, and the mechanical analysis of the single-cell unit is performed by establishing the theoretical model. Additionally, simulations are performed to evaluate the maximum stress-bearing capacity and compressive performance of the uniform arrangement and gradient arrangement of the cells. Finally, the static analysis is performed for the cell-filled rod and the unmodified rod, respectively, and the simulation results demonstrate the effectiveness and feasibility of the designed ultra-light and ultra-stiff truss type of lattice structures. In future studies, experiments will be conducted to further evaluate the performance of the designed lattice structures.

Keywords: additive manufacturing, lattice structures, metamaterial, robotic knee exoskeleton

Procedia PDF Downloads 75
1880 2-Dimensional Kinematic Analysis on Sprint Start with Sprinting Performance of Novice Athletes

Authors: Satpal Yadav, Biswajit Basumatary, Arvind S. Sajwan, Ranjan Chakravarty

Abstract:

The purpose of the study was to assess the effect of 2D kinematical selected variables on sprint start with sprinting performance of novice athletes. Six (3 National and 3 State level) athletes of sports authority of India, Guwahati has been selected for this study. The mean (M) and standard deviation (SD) of sprinters were age (17.44, 1.55), height (1.74m, .84m), weight (62.25 kg, 4.55), arm length (65.00 cm, 3.72) and leg length (96.35 cm, 2.71). Biokin-2D motion analysis system V4.5 can be used for acquiring two-dimensional kinematical data/variables on sprint start with Sprinting Performance. For the purpose of kinematic analysis a standard motion driven camera which frequency of the camera was 60 frame/ second i.e. handy camera of Sony Company were used. The sequence of photographic was taken under controlled condition. The distance of the camera from the athletes was 12 mts away and was fixed at 1.2-meter height. The result was found that National and State level athletes significant difference in there, trajectory knee, trajectory ankle, displacement knee, displacement ankle, linear velocity knee, linear velocity ankle, and linear acceleration ankle whereas insignificant difference was found between National and State level athletes in their linear acceleration knee joint on sprint start with sprinting performance. For all the Statistical test the level of significance was set at p<0.05.

Keywords: 2D kinematic analysis, sprinting performance, novice athletes, sprint start

Procedia PDF Downloads 293
1879 Preventative Maintenance, Impact on the Optimal Replacement Strategy of Secondhand Products

Authors: Pin-Wei Chiang, Wen-Liang Chang, Ruey-Huei Yeh

Abstract:

This paper investigates optimal replacement and preventative maintenance policies of secondhand products under a Finite Planning Horizon (FPH). Any consumer wishing to replace their product under FPH would have it undergo minimal repairs. The replacement provided would be required to undergo periodical preventive maintenance done to avoid product failure. Then, a mathematical formula for disbursement cost for products under FPH can be derived. Optimal policies are then obtained to minimize cost. In the first of two segments of the paper, a model for initial product purchase of either new or secondhand products is used. This model is built by analyzing product purchasing price, surplus value of product, as well as the minimal repair cost. The second segment uses a model for replacement products, which are also secondhand products with no limit on usage. This model analyzes the same components as the first as well as expected preventative maintenance cost. Using these two models, a formula for the expected final total cost can be developed. The formula requires four variables (optimal preventive maintenance level, preventive maintenance frequency, replacement timing, age of replacement product) to find minimal cost requirement. Based on analysis of the variables using the expected total final cost model, it was found that the purchasing price and length of ownership were directly related. Also, consumers should choose the secondhand product with the higher usage for replacement. Products with higher initial usage upon acquisition require an earlier replacement schedule. In this case, replacements should be made with a secondhand product with less usage. In addition, preventative maintenance also significantly reduces cost. Consumers that plan to use products for longer periods of time replace their products later. Hence these consumers should choose the secondhand product with lesser initial usage for replacement. Preventative maintenance also creates significant total cost savings in this case. This study provides consumers with a method of calculating both the ideal amount of usage of the products they should purchase as well as the frequency and level of preventative maintenance that should be conducted in order to minimize cost and maintain product function.

Keywords: finite planning horizon, second hand product, replacement, preventive maintenance, minimal repair

Procedia PDF Downloads 451
1878 The Applications of Four Fingers Theory: The Proof of 66 Acupoints under the Human Elbow and Knee

Authors: Chih-I. Tsai, Yu-Chien. Lin

Abstract:

Through experiences of clinical practices, it is discovered that locations on the body at a level of four fingerbreadth above and below the joints are the points at which muscles connect to tendons, and since the muscles and tendons possess opposite characteristics, muscles are full of blood but lack qi, while tendons are full of qi but lack blood, these points on our body become easily blocked. It is proposed that through doing acupuncture or creating localized pressure to the areas four fingerbreadths above and below our joints, with an elastic bandage, we could help the energy, also known as qi, to flow smoothly in our body and further improve our health. Based on the Four Fingers Theory, we understand that human height is 22 four fingerbreadths. In addition, qi and blood travel through 24 meridians, 50 times each day, and they flow through 6 cun with every human breath. We can also understand the average number of human heartbeats is 75 times per minute. And the function of qi-blood circulation system in Traditional Chinese Medicine is the same as the blood circulation in Western Medical Science. Informed by Four Fingers Theory, this study further examined its applications in acupuncture practices. The research question is how Four Fingers Theory proves what has been mentioned in Nei Jing that there are 66 acupoints under a human’s elbow and knee. In responding to the research question, there are 66 acupoints under a human’s elbow and knee. Four Fingers Theory facilitated the creation of the acupuncture naming and teaching system. It is expected to serve as an approachable and effective way to deliver knowledge of acupuncture to the public worldwide.

Keywords: four fingers theory, meridians circulation, 66 acupoints under human elbow and knee, acupuncture

Procedia PDF Downloads 260
1877 Design and Development of an Expanded Polytetrafluoroethylene Valved Conduit with Sinus of Valsalva

Authors: Munirah Ismail, Joon Hock Yeo

Abstract:

Babies born with Tetralogy of Fallot, a congenital heart defect, are required to undergo reconstruction surgery to create a valved conduit. As the child matures, the partially reconstructed pulmonary conduit increases in diameter, while the size of the reconstructed valve remains the same. As a result, follow up surgery is required to replace the undersized valve. Thus, in this project, we evaluated the in-vitro performance of a bi-leaflet valve design in terms of percentage regurgitation with increasing artery (conduit) diameters. Results revealed percentage regurgitations ranging from 13% to 34% for conduits tested. It was observed that percentage of regurgitation increased exponentially with increasing diameters. While the amount of regurgitation may seem severe, it is deemed acceptable, and this valve could potentially reduce the frequency of re-operation in the lifetime of pediatric patients.

Keywords: pulmonary heart valve, tetralogy of fallot, expanded polytetrafluoroethylene valve, pediatric heart valve replacement

Procedia PDF Downloads 146
1876 Energy Efficient Autonomous Lower Limb Exoskeleton for Human Motion Enhancement

Authors: Nazim Mir-Nasiri, Hudyjaya Siswoyo Jo

Abstract:

The paper describes conceptual design, control strategies, and partial simulation for a new fully autonomous lower limb wearable exoskeleton system for human motion enhancement that can support its weight and increase strength and endurance. Various problems still remain to be solved where the most important is the creation of a power and cost efficient system that will allow an exoskeleton to operate for extended period without batteries being frequently recharged. The designed exoskeleton is enabling to decouple the weight/mass carrying function of the system from the forward motion function which reduces the power and size of propulsion motors and thus the overall weight, cost of the system. The decoupling takes place by blocking the motion at knee joint by placing passive air cylinder across the joint. The cylinder is actuated when the knee angle has reached the minimum allowed value to bend. The value of the minimum bending angle depends on usual walk style of the subject. The mechanism of the exoskeleton features a seat to rest the subject’s body weight at the moment of blocking the knee joint motion. The mechanical structure of each leg has six degrees of freedom: four at the hip, one at the knee, and one at the ankle. Exoskeleton legs are attached to subject legs by using flexible cuffs. The operation of all actuators depends on the amount of pressure felt by the feet pressure sensors and knee angle sensor. The sensor readings depend on actual posture of the subject and can be classified in three distinct cases: subject stands on one leg, subject stands still on both legs and subject stands on both legs but transit its weight from one leg to other. This exoskeleton is power efficient because electrical motors are smaller in size and did not participate in supporting the weight like in all other existing exoskeleton designs.

Keywords: energy efficient system, exoskeleton, motion enhancement, robotics

Procedia PDF Downloads 345
1875 Strabismus Management in Retinoblastoma Survivors

Authors: Babak Masoomian, Masoud Khorrami Nejad, Hamid Riazi Esfahani

Abstract:

Purpose: To report the result of strabismus surgery in eye-salvaged retinoblastoma (Rb) patients. Methods: A retrospective case series including 18 patients with Rb and strabismus who underwent strabismus surgery after completing tumor treatment by a single pediatric ophthalmologist. Results: A total of 18 patients (10 females and 8 males) were included with a mean age of 13.3 ± 3.0 (range, 2-39) months at the time tumor presentation and 6.0 ± 1.5 (range, 4-9) years at the time of strabismus surgery. Ten (56%) patients had unilateral, and 8(44%) had bilateral involvement, and the most common worse eye tumor’s group was D (n=11), C (n=4), B (n=2) and E (n=1). Macula was involved by the tumors in 12 (67%) patients. The tumors were managed by intravenous chemotherapy (n=8, 47%), intra-arterial chemotherapy (n=7, 41%) and both (n=3, 17%). After complete treatment, the average time to strabismus surgery was 29.9 ± 20.5 (range, 12-84) months. Except for one, visual acuity was equal or less than 1.0 logMAR (≤ 20/200) in the affected eye. Seven (39%) patients had exotropia, 11(61%) had esotropia (P=0.346) and vertical deviation was found in 8 (48%) cases. The angle of deviation was 42.0 ± 10.4 (range, 30-60) prism diopter (PD) for esotropic and 35.7± 7.9 (range, 25-50) PD for exotropic patients (P=0.32) that after surgery significantly decreased to 8.5 ± 5.3 PD in esotropic cases and 5.9±6.7 PD in exotropic cases (P<0.001). The mean follow-up after surgery was 15.2 ± 2.0 (range, 10-24) months, in which 3 (17%) patients needed a second surgery. Conclusion: Strabismus surgery in treated Rb is safe, and results of the surgeries are acceptable and close to the general population. There was not associated with tumor recurrence or metastasis.

Keywords: retinoblastoma, strabismus, chemotherapy, surgery

Procedia PDF Downloads 33