Search results for: high dose dosimetry
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 20379

Search results for: high dose dosimetry

20199 Evaluation of the Photo Neutron Contamination inside and outside of Treatment Room for High Energy Elekta Synergy® Linear Accelerator

Authors: Sharib Ahmed, Mansoor Rafi, Kamran Ali Awan, Faraz Khaskhali, Amir Maqbool, Altaf Hashmi

Abstract:

Medical linear accelerators (LINAC’s) used in radiotherapy treatments produce undesired neutrons when they are operated at energies above 8 MeV, both in electron and photon configuration. Neutrons are produced by high-energy photons and electrons through electronuclear (e, n) a photonuclear giant dipole resonance (GDR) reactions. These reactions occurs when incoming photon or electron incident through the various materials of target, flattening filter, collimators, and other shielding components in LINAC’s structure. These neutrons may reach directly to the patient, or they may interact with the surrounding materials until they become thermalized. A work has been set up to study the effect of different parameter on the production of neutron around the room by photonuclear reactions induced by photons above ~8 MeV. One of the commercial available neutron detector (Ludlum Model 42-31H Neutron Detector) is used for the detection of thermal and fast neutrons (0.025 eV to approximately 12 MeV) inside and outside of the treatment room. Measurements were performed for different field sizes at 100 cm source to surface distance (SSD) of detector, at different distances from the isocenter and at the place of primary and secondary walls. Other measurements were performed at door and treatment console for the potential radiation safety concerns of the therapists who must walk in and out of the room for the treatments. Exposures have taken place from Elekta Synergy® linear accelerators for two different energies (10 MV and 18 MV) for a given 200 MU’s and dose rate of 600 MU per minute. Results indicates that neutron doses at 100 cm SSD depend on accelerator characteristics means jaw settings as jaws are made of high atomic number material so provides significant interaction of photons to produce neutrons, while doses at the place of larger distance from isocenter are strongly influenced by the treatment room geometry and backscattering from the walls cause a greater doses as compare to dose at 100 cm distance from isocenter. In the treatment room the ambient dose equivalent due to photons produced during decay of activation nuclei varies from 4.22 mSv.h−1 to 13.2 mSv.h−1 (at isocenter),6.21 mSv.h−1 to 29.2 mSv.h−1 (primary wall) and 8.73 mSv.h−1 to 37.2 mSv.h−1 (secondary wall) for 10 and 18 MV respectively. The ambient dose equivalent for neutrons at door is 5 μSv.h−1 to 2 μSv.h−1 while at treatment console room it is 2 μSv.h−1 to 0 μSv.h−1 for 10 and 18 MV respectively which shows that a 2 m thick and 5m longer concrete maze provides sufficient shielding for neutron at door as well as at treatment console for 10 and 18 MV photons.

Keywords: equivalent doses, neutron contamination, neutron detector, photon energy

Procedia PDF Downloads 427
20198 Kinetic and Thermodynamic Study of Nitrates Removal by Sorption on Biochar

Authors: Amira Touil, Achouak Arfaoui, Ibtissem Mannaii

Abstract:

The aim of this work is to monitor the process adsorption of nitrates by the biochar via studying the influence of various parameters on the adsorption of this pollutant by biochar in a synthetic aqueous solution. The results which obtained indicate that the 4g/L biochar dose is the most efficient in terms of nitrates removal in aqueous solution. The biochar exhibited a good affinity for nitrates after 1hour of contact. The yield of removal of nitrate by the biochar decreases with the increase of pH of the solution and increases with increasing temperature (60°C>40°C>20°C). The best removal yield is about 80% of the initial concentration introduced (25mg/L) obtained at pH=2, T=60°C, and dose of biochar=4g/L. The second order model fit the nitrate adsorption kinetics of biochar with a high coefficient of determination (R2≥0.997); and a new equation correlating the rate constant of the reaction with temperature and pH was been built. Freundlich isotherms performed well to fit the nitrate adsorption data by biochar (R2>0.96) compared to Langmuir isotherms. The thermodynamic parameters (ΔH°, ΔG°, ΔS°) have been calculated for predicting the nature of adsorption.

Keywords: pollution, biochar, nitrate, adsorption

Procedia PDF Downloads 62
20197 Morroniside Intervention Mechanism of Renal Lesions, a Combination Model of AGEs Exacerbation of STZ-Induced Diabetes Mellitus

Authors: Hui-Qin Xu, Xing Lv, Yu-Han Tao

Abstract:

The depth study aimed on the mechanism of morroniside in protecting diabetic nephropathy. The diabetic mice models with blood glucose above 15mmol/L were divided into model, aminoguanidine, metformin, captopril, morroniside low-dose, and morroniside high-dose groups. And normal group was set simultaneously. All groups were fed with high AGEs food except normal group. Each group was intragastric administration of the corresponding medicine except model and normal groups. After 12 weeks, all the indictors were measured. It showed that the morroniside could reduce blood glucose significantly, urinary protein, serum urea nitrogen, creatine, pathological changes, AGEs levels, renal cortex RAGE mRNA and RAGE protein expression levels; increase food consumption, water intake, urine volume, insulin secretion. As a conclusion, morroniside from cornus officinalis can protect renal in diabetic mice, its mechanism may be related to the proliferation of islet cells, rectify glycometabolism, reduce serum and kidney AGEs content, and descend renal RAGEmRNA and RAGE protein expression levels.

Keywords: cornus officinalis, diabetic nephropathy, morroniside, RAGE protein

Procedia PDF Downloads 425
20196 Status of Radiation Protection at Radiation Oncology, BPKM Cancer Hospital, Nepal

Authors: Surendra B. Chand, P. P. Chaurasia, M. P. Adhikari, R. N. Yadav

Abstract:

Objective: The objective of this work was to evaluate all the safety procedures toward the radiation protection for workers in the radiation oncology department. Materials and Methods: The annual thermoluminescent dosimeters (TLDs) reports for five years of the staffs were evaluated, radiation surveys were done in the control consoles, radiotherapy machines room and waiting areas of all machines using Aloka survey meter. Results: The five years TLD reports shows that the whole body dose of the individual staffs is found within the annual dose limit except the accidental exposures. Radiation exposures in the working areas are also safe limits. Conclusion: The radiation safety practices for radiation protection are satisfactory and the radiation workers of the departments are found working within the safe limit.

Keywords: radiation protection, safety, ICRP, dose limits, TLD, radiation devices

Procedia PDF Downloads 541
20195 Comparison of Titanium and Aluminum Functions as Spoilers for Dose Uniformity Achievement in Abutting Oblique Electron Fields: A Monte Carlo Simulation Study

Authors: Faranak Felfeliyan, Parvaneh Shokrani, Maryam Atarod

Abstract:

Introduction Using electron beam is widespread in radiotherapy. The main criteria in radiation therapy is to irradiate the tumor volume with maximum prescribed dose and minimum dose to vital organs around it. Using abutting fields is common in radiotherapy. The main problem in using abutting fields is dose inhomogeneity in the junction region. Electron beam divergence and lateral scattering may lead to hot and cold spots in the junction region. One solution for this problem is using of a spoiler to broaden the penumbra and uniform dose in the junction region. The goal of this research was to compare titanium and aluminum effects as a spoiler for dose uniformity achievement in the junction region of oblique electron fields with Monte Carlo simulation. Dose uniformity in the junction region depends on density, scattering power, thickness of the spoiler and the angle between two fields. Materials and Methods In this study, Monte Carlo model of Siemens Primus linear accelerator was simulated for a 5 MeV nominal energy electron beam using manufacture provided specifications. BEAMnrc and EGSnrc user code were used to simulate the treatment head in electron mode (simulation of beam model). The resulting phase space file was used as a source for dose calculations for 10×10 cm2 field size at SSD=100 cm in a 30×30×45 cm3 water phantom using DOSXYZnrc user code (dose calculations). An automatic MP3-M water phantom tank, MEPHYSTO mc2 software platform and a Semi-Flex Chamber-31010 with sensitive vol­ume of 0.125 cm3 (PTW, Freiburg, Germany) were used for dose distribution measurements. Moreover, the electron field size was 10×10 cm2 and SSD=100 cm. Validation of devel­oped beam model was done by comparing the measured and calculated depth and lateral dose distributions (verification of electron beam model). Simulation of spoilers (using SLAB compo­nent module) placed at the end of the electron applicator, was done using previously vali­dated phase space file for a 5 MeV nominal energy and 10×10 cm2 field size (simulation of spoiler). An in-house routine was developed in order to calculate the combined isodose curves re­sulting from the two simulated abutting fields (calculation of dose distribution in abutting electron fields). Results Verification of the developed 5.9 MeV elec­tron beam model was done by comparing the calculated and measured dose distributions. The maximum percentage difference between calculated and measured PDD was 1%, except for the build-up region in which the difference was 2%. The difference between calculated and measured profile was 2% at the edges of the field and less than 1% in other regions. The effect of PMMA, aluminum, titanium and chromium in dose uniformity achievement in abutting normal electron fields with equivalent thicknesses to 5mm PMMA was evaluated. Comparing R90 and uniformity index of different materials, aluminum was chosen as the optimum spoiler. Titanium has the maximum surface dose. Thus, aluminum and titanium had been chosen to use for dose uniformity achievement in oblique electron fields. Using the optimum beam spoiler, junction dose decreased from 160% to 110% for 15 degrees, from 180% to 120% for 30 degrees, from 160% to 120% for 45 degrees and from 180% to 100% for 60 degrees oblique abutting fields. Using Titanium spoiler, junction dose decreased from 160% to 120% for 15 degrees, 180% to 120% for 30 degrees, 160% to 120% for 45 degrees and 180% to 110% for 60 degrees. In addition, penumbra width for 15 degrees, without spoiler in the surface was 10 mm and was increased to 15.5 mm with titanium spoiler. For 30 degrees, from 9 mm to 15 mm, for 45 degrees from 4 mm to 6 mm and for 60 degrees, from 5 mm to 8 mm. Conclusion Using spoilers, penumbra width at the surface increased, size and depth of hot spots was decreased and dose homogeneity improved at the junc­tion of abutting electron fields. Dose at the junction region of abutting oblique fields was improved significantly by using spoiler. Maximum dose at the junction region for 15⁰, 30⁰, 45⁰ and 60⁰ was decreased about 40%, 60%, 40% and 70% respectively for Titanium and about 50%, 60%, 40% and 80% for Aluminum. Considering significantly decrease in maximum dose using titanium spoiler, unfortunately, dose distribution in the junction region was not decreased less than 110%.

Keywords: abutting fields, electron beam, radiation therapy, spoilers

Procedia PDF Downloads 142
20194 Annual Effective Dose Associated with Radon in Groundwater Samples from Mining Communities Within the Ife-Ilesha Schist Belt, Southwestern Nigeria.

Authors: Paulinah Oyindamola Fasanmi, Matthew Omoniyi Isinkaye

Abstract:

In this study, the activity concentration of ²²²Rn in groundwater samples collected from gold and kaolin mining communities within the Ife-Ilesha schist belt, southwestern Nigeria, with their corresponding annual effective doses have been determined using the Durridge RAD-7, radon-in-water detector. The mean concentration of ²²²Rn in all the groundwater samples was 13.83 Bql-¹. In borehole water, ²²²Rn had a mean value of 20.68 Bql-¹, while it had a mean value of 11.67 Bql-¹ in well water samples. The mean activity concentration of radon obtained from the gold mining communities ranged from 1.6 Bql-¹ from Igun town to 4.8 Bql-¹ from Ilesha town. A higher mean value of 41.8 Bql-¹ was, however, obtained from Ijero, which is the kaolin mining community. The mean annual effective dose due to ingestion and inhalation of radon from groundwater samples was obtained to be 35.35 μSvyr-¹ and 34.86 nSvyr-¹, respectively. The mean annual ingestion dose estimated for well water samples was 29.90 μSvyr-¹, while 52.85 μSvyr-¹ was obtained for borehole water samples. On the other hand, the mean annual inhalation dose for well water was 29.49 nSvyr-¹, while for borehole water, 52.13 nSvyr-¹ was obtained. The mean annual effective dose due to ingestion of radon in groundwater from the gold mining communities ranged from 4.10 μSvyr-¹ from Igun to 13.1 μSvyr-¹ from Ilesha, while a mean value of 106.7 μSvyr-¹ was obtained from Ijero kaolin mining community. For inhalation, the mean value varied from 4.0 nSvyr-¹ from Igun to 12.9 nSvyr-¹ from Ilesha, while 105.2 nSvyr-¹ was obtained from the kaolin mining community. The mean annual effective dose due to ingestion and inhalation is lower than the reference level of 100 μSvyr-¹ recommended by World Health Organization except for values obtained from Ijero kaolin mining community, which exceeded the reference levels. It has been concluded that as far as radon-related health risks are concerned, groundwater from gold mining communities is generally safe, while groundwater from kaolin mining communities needs mitigation and monitoring. It has been discovered that Kaolin mining impacts groundwater with ²²²Rn than gold mining. Also, the radon level in borehole water exceeds its level in well water.

Keywords: 222Rn, Groundwater, Radioactivity, Annual Effective Dose, Mining.

Procedia PDF Downloads 39
20193 Effect of Gamma Irradiation on Structural and Optical Properties of ZnO/Mesoporous Silica Nanocomposite

Authors: K. Sowri Babu, P. Srinath, N. Rajeswara Rao, K. Venugopal Reddy

Abstract:

The effect of gamma ray irradiation on morphology and optical properties of ZnO/Mesoporous silica (MPS) nanocomposite was studied. The ZnO/MPS nanocomposite was irradiated with gamma rays of doses 30, 60, and 90 kGy and dose-rate of irradiation was 0.15 kGy/hour. Irradiated samples are characterized with FE-SEM, FT-IR, UV-vis, and Photoluminescence (PL) spectrometers. SEM pictures showed that morphology changed from spherical to flake like morphology. UV-vis analysis showed that the band gap increased with increase of gamma ray irradiation dose. This enhancement of the band gap is assigned to the depletion of oxygen vacancies with irradiation. The intensity of PL peak decreased gradually with increase of gamma ray irradiation dose. The decrease in PL intensity is attributed to the decrease of oxygen vacancies at the interface due to poor interface and improper passivation between ZnO/MPS.

Keywords: ZnO nanoparticles, nanocomposites, mesoporous silica, photoluminescence

Procedia PDF Downloads 200
20192 The Nutritive Value of Fermented Sago Pith (Metroxylon sago Rottb) Enriched with Micro Nutrients for Poultry Feed

Authors: Wizna, Helmi Muis, Hafil Abbas

Abstract:

An experiment was conducted to improve the nutrient value of sago pith (Metroxylon sago Rottb) supplemented with Zn, Sulfur and urea through fermentation by using cellulolytic bacteria (Bacillus amyloliquefaciens) as inoculums. The experiment was determination of the optimum dose combination (dosage of Zn, S and urea) for sago pith fermentation based on nutrient quality and quantity of these fermented products. The study was conducted in experimental method, using the completely randomized design in factorial with 3 treatments consist of: factor A (Dose of urea: A1 = 2.0%, A2 = 3.0%), factor B (Dose of S: B1 = 0.2%, B2 = 0.4%) and factor C (Dose of Zn: C1 = 0.0025%, C2 = 0.005%). Results of study showed that optimum condition for fermentation process of sago pith with B. amyloliquefaciens caused a change of nutrient content was obtained at urea (3%), S (0,2%), and Zn (0,0025%). This fermentation process was able to increase amino acid average, reduce crude fiber content by 67% and increase crude protein by 433%, which made the nutritional value of the product based on dry matter was 18.22% crude protein, 12.42% crude fiber, 2525 Kcal/kg metabolic energy and 65.73% nitrogen retention.

Keywords: fermentation, sago pith, sulfur, Zn, urea, Bacillus amyloliquefaciens

Procedia PDF Downloads 483
20191 Optimization of the Drinking Water Treatment Process Improvement of the Treated Water Quality by Using the Sludge Produced by the Water Treatment Plant

Authors: M. Derraz, M. Farhaoui

Abstract:

Problem statement: In the water treatment processes, the coagulation and flocculation processes produce sludge according to the level of the water turbidity. The aluminum sulfate is the most common coagulant used in water treatment plants of Morocco as well as many countries. It is difficult to manage Sludge produced by the treatment plant. However, it can be used in the process to improve the quality of the treated water and reduce the aluminum sulfate dose. Approach: In this study, the effectiveness of sludge was evaluated at different turbidity levels (low, medium, and high turbidity) and coagulant dosage to find optimal operational conditions. The influence of settling time was also studied. A set of jar test experiments was conducted to find the sludge and aluminum sulfate dosages in order to improve the produced water quality for different turbidity levels. Results: Results demonstrated that using sludge produced by the treatment plant can improve the quality of the produced water and reduce the aluminum sulfate using. The aluminum sulfate dosage can be reduced from 40 to 50% according to the turbidity level (10, 20, and 40 NTU). Conclusions/Recommendations: Results show that sludge can be used in order to reduce the aluminum sulfate dosage and improve the quality of treated water. The highest turbidity removal efficiency is observed within 6 mg/l of aluminum sulfate and 35 mg/l of sludge in low turbidity, 20 mg/l of aluminum sulfate and 50 mg/l of sludge in medium turbidity and 20 mg/l of aluminum sulfate and 60 mg/l of sludge in high turbidity. The turbidity removal efficiency is 97.56%, 98.96%, and 99.47% respectively for low, medium and high turbidity levels.

Keywords: coagulation process, coagulant dose, sludge reuse, turbidity removal

Procedia PDF Downloads 206
20190 Hepatoprotective Assessment of L-Ascorbate 1-(2-Hydroxyethyl)-4,6-Dimethyl-1, 2-Dihydropyrimidine-2-on in Toxic Liver Damage Test

Authors: Vladimir Zobov, Nail Nazarov, Alexandra Vyshtakalyuk, Vyacheslav Semenov, Irina Galyametdinova, Vladimir Reznik

Abstract:

The aim of this study was to investigate hepatoprotective properties of the Xymedon derivative L-ascorbate 1- (2-hydroxyethyl)-4,6-dimethyl-1,2-dihydropyrimidine-2-one (XD), which exhibits high efficiency as actoprotector. The study was carried out on 68 male albino rats weighing 250-400 g using preventive exposure to the test preparation. Effectiveness of XD win comparison with effectiveness of Xymedon (original substance) after administration of the compounds in identical doses. Maximum dose was 20 mg/kg. The animals orally received Xymedon or its derivative in doses of 10 and 20 mg/kg over 4 days. In 1-1.5 h after drug administration, CCl4 in vegetable oil (1:1) in a dose of 2 ml/kg. Controls received CCl4 but without hepatoprotectors. Intact control group consisted of rats, not receiving CCl4 or other compounds. The next day after the last administration of CCl4 and compounds under study animals were dehematized under ether anesthesia, blood and liver samples were taken for biochemical and histological analysis. Xymedon and XD administered according to the preventice scheme, exerted hepatoprotective effects: Xymedon — in the dose of 20 mg/kg, XD — in doses of 10 and 20 mg/kg. The drugs under study had different effects on liver condition, affected by induction with CCl4. Xymedon had a more pronounced effect both on the ALT level, which can be elevated not only due to destructive changes in hepatocytes, but also as a cholestasis manifestation, and on the serum total protein level, which reflects protein synthesis in liver. XD had a more pronounced effect on AST level, which is one of the markers of hepatocyte damage. Lower effective dose of XD — 10 mg/kg, compared to Xymedon effective according to, and its pronounced effect on AST, the hepatocyte cytolysis marker, is indicative of its higher preventive effectiveness, compared to Xymedon. This work was performed with the financial support of Russian Science Foundation (grant No: 14-50-00014).

Keywords: hepatoprotectors, pyrimidine derivatives, toxic liver damage, xymedon

Procedia PDF Downloads 272
20189 Reduction of Patient’s Dose of I-131 Therapy by Used Local Diuretic Juice

Authors: Mosab kh. A. A. Bashir, E. Mohamed-Ahmed

Abstract:

The aim of the study is to compare the results of the external exposure and the range of the dose spread by the patients, hospitalized in two different groups of 3-5 d receiving radioiodine therapy because of thyroid cancer, and one of group were giving the local diuretic plant (barley) as local juice. The control group was 28 patients they were isolated as international precautions after taken I-131 capsule 100 mCi, and their external exposure was recorded day by day after first 24 hrs. and the distance for external measurement was 1 m at the abdominal level. The mean of external exposure values of patients at fourth day were 30.24±12.92 µSv h−1. The second group after taking I-131 capsule 100 mCi we were given barley juice (250 mL) after every meal three times on day and their external exposure was recorded day by day after first 24 hrs. The mean of external exposure values of patients of this group at third day was 26.92±9.89 (14-55) µSv h−1. It was observed that the external exposure from the second group clearly decreased to low levels which contributed to the decrease in patient dose and also to the decrease in the exposure from the patient to his/her family.

Keywords: local diuretic juice, therapy, radiation medicine, diuretic plant

Procedia PDF Downloads 286
20188 Effect of High Dose of Black Tea Extract on Physiological Parameters of Mother and Pups in Experimental Albino Rats

Authors: Avijit Dey, Antony Gomes, Subir Chandra Dasgupta

Abstract:

Tea (Camellia sinensis) is the most popular beverages in the world and is ranked second after the water. Tea has been considered as a health promoting beverage since ancient times due to its health-promoting activity. Recently, immunomodulatory, anti-arthritic, antioxidant, anticancer and cardioprotective activity of tea has been established. Very few studies have demonstrated the effect of high dose of black tea on health. The aim of the present study was to evaluate the role of low & high dose of Black Tea Extract (BTE) on the different physiological parameters of mother and pups during prenatal and postnatal developmental period in the experimental rodent. BTE was orally administered in LD (50mg BTE/kg/day) and HD (100mg BTE/kg/day) except control groups of rats (n=6/group) throughout the prenatal (day 0-21) and postnatal (day 21-42) periods. During prenatal period (0, 7th, 14th, 20th days) body weight, urinary calcium, magnesium, urea and creatinine was measured. In postnatal period physical (0, 10th, 21th days) parameters of pups like body weight, cranial length, cranial diameter, neck width, tail length, craniosacral length of pups were analyzed. Liver and lungs from pups and kidney spleen, etc. from mothers were collected on day 42 for histopathological studies. The comparative urine strip and morphology of RBC was also analyzed by SEM from mothers of different groups on day 42. The level of cytokines like IL-1alpha, IL-1beta, IL-6, IL-10, TNF-alpha were analysed by enzyme-linked immunosorbent assay (ELISA) on day 0, day 20 and day 42. The body weight of LD and HD mothers were also significantly (P<0.05) less than control mothers at 20th day of pregnancy and there was also significant changes in urinary calcium, urea, creatinine. The bio morphometric analysis of pups showed significant alteration (P<0.05) in HD groups relative to control. Some histological alterations were also observed in pups and mothers. Comparative urine strip analysis and morphology of RBC showed significant changes in treated groups. LD and HD treated mothers showed an increase in proinflammatory cytokines like IL-1beta, TNF-alpha and decrease in anti-inflammatory cytokine-like IL-10 on day 20 compared to PC mothers. This study clearly indicated that high dose of BTE possesses detrimental effect on pregnant mother and the pup. Further studies are in progress to elucidate the molecular mechanism of actions. This project work has been sponsored by National Tea Research Foundation vide Project Sanction No.: 17 (305)/2013/4423 dated 11th March, 2014. All experimental protocols described in the study were approved by animal ethics committee.

Keywords: black tea extract, pregnancy, prenatal and postnatal development, inflammation

Procedia PDF Downloads 250
20187 Evaluation of Naringenin Role in Inhibiton of Lung Tumor Progression in Mice

Authors: Vishnu Varthan Vaithiyalingamjagannathan, M. N. Sathishkumar, K. S. Lakhsmi, D. Satheeshkumar, Srividyaammayappanrajam

Abstract:

Background:Naringenin, aglycone flavonoid possess certain activities like anti-oxidant, anti-estrogenic, anti-diabetic, cardioprotective, anti-obesity,anti-inflammatory, hepatoprotective and also have anti-cancer characteristics like carcinogenic inactivation, cell cycle arrest, anti-proliferation, apoptosis, anti-angiogenesis and enhances anti-oxidant activity. Methodology:The inhibitory effect of Naringenin in lung tumor progression estimated with adenocarcinoma (A549) cell lines (in vitro) and C57BL/6 mice injected with 5 X 106A549 cell lines (in vivo) in a tri-dose manner (Naringenin 100mg/kg,150mg/kg, and 200mg/kg) compared with standard chemotherapy drug cisplatin (7mg/kg). Results:The results of the present study revealed a dose-dependent activity in Naringenin and combination with cisplatin at a higher dose which showed decreased tumor progression in mice. In vitro studies carried out for estimation of cell survival and Nitric Oxide (NO) level, shows dose dependent action of Naringenin with IC50 value of 42µg/ml. In vivo studies were carried out in C57BL/6 mice. Naringenin satisfied the condition of an anti-cancer molecule with its characteristics in fragmentation assay, Zymography assay, anti-oxidant, and myeloperoxidase studies, than cisplatin which failed in anti-oxidant and myeloperoxidase effect. Both in vitro and in vivo establishes dose dependent decrease in NO levels. But whereas, Naringenin showed adverse results in Matrix Metalloproteinase (MMP) enzymatic levels with increase in dose levels. Conclusion:From the present study, Naringenin could suppress the lung tumor progression when given individually and also in combinatorial with standard chemotherapy drug.

Keywords: naringenin, in vitro, cell line, anticancer

Procedia PDF Downloads 410
20186 Nephroprotective Activity of Aqueous Methanolic Extract of Aerva Lanata (Busehri Booti) against Cisplatin Induced Nephrotoxicity in Rats

Authors: Mohd Aslam Aslam

Abstract:

Chronic renal failure is a debilitating condition responsible for high morbidity and mortality. Because of its costs and the complexity of its treatment, proper care is available to very few patients in India. According to researchers, the number of adults aged 30 or older who have chronic kidney disease is projected to increase from 13.2 percent currently, to 14.4 percent in 2020 and 16.7 percent in 2030. The aerial part of Aerva lanata (Busehri booti) have been used in kidney disorders by the Unani physicians. In the present study, the effect of extract of Aerva lanata was investigated on cisplatin-induced nephrotoxicity in rats. The renal effects of this drug was evaluated by monitoring levels of blood urea nitrogen (BUN), serum creatinine, serum uric acid in blood and histopathological examination of kidney. Aerva lanata was evaluated at two different doses (1400 mg/kg and 2800 mg/kg). The effect of higher dose was more pronounced in terms of inhibition in the rise of BUN, serum creatinine and uric acid. Higher dose show greater prevention in the rise of BUN, serum creatinine, and uric acid. The histopathological examination of the kidney tissue of the rats treated with aqueous methanolic extract of Aerva lanata (Higher dose-2800 mg/kg) showed marked inhibition of glomerular congestion, tubular casts, peritubular congestion, epithelial desquamation, blood vessel congestion, interstitial edema and inflammatory cells produced by the cisplatin-induced nephrotoxicity. This finding clearly indicates the protective role of Aerva lanata at higher dose. Present investigation validates the use of Aerva lanata in kidney disorders by Unani physicians.

Keywords: Aerva lanata, Busehri booti, nephroprotective, unani medicine

Procedia PDF Downloads 200
20185 Standardizing and Achieving Protocol Objectives for ChestWall Radiotherapy Treatment Planning Process using an O-ring Linac in High-, Low- and Middle-income Countries

Authors: Milton Ixquiac, Erick Montenegro, Francisco Reynoso, Matthew Schmidt, Thomas Mazur, Tianyu Zhao, Hiram Gay, Geoffrey Hugo, Lauren Henke, Jeff Michael Michalski, Angel Velarde, Vicky de Falla, Franky Reyes, Osmar Hernandez, Edgar Aparicio Ruiz, Baozhou Sun

Abstract:

Purpose: Radiotherapy departments in low- and middle-income countries (LMICs) like Guatemala have recently introduced intensity-modulated radiotherapy (IMRT). IMRT has become the standard of care in high-income countries (HIC) due to reduced toxicity and improved outcomes in some cancers. The purpose of this work is to show the agreement between the dosimetric results shown in the Dose Volume Histograms (DVH) to the objectives proposed in the adopted protocol. This is the initial experience with an O-ring Linac. Methods and Materials: An O-Linac Linac was installed at our clinic in Guatemala in 2019 and has been used to treat approximately 90 patients daily with IMRT. This Linac is a completely Image Guided Device since to deliver each radiotherapy session must take a Mega Voltage Cone Beam Computerized Tomography (MVCBCT). In each MVCBCT, the Linac deliver 9 UM, and they are taken into account while performing the planning. To start the standardization, the TG263 was employed in the nomenclature and adopted a hypofractionated protocol to treat ChestWall, including supraclavicular nodes achieving 40.05Gy in 15 fractions. The planning was developed using 4 semiarcs from 179-305 degrees. The planner must create optimization volumes for targets and Organs at Risk (OARs); the difficulty for the planner was the dose base due to the MVCBCT. To evaluate the planning modality, we used 30 chestwall cases. Results: The plans created manually achieve the protocol objectives. The protocol objectives are the same as the RTOG1005, and the DHV curves look clinically acceptable. Conclusions: Despite the O-ring Linac doesn´t have the capacity to obtain kv images, the cone beam CT was created using MV energy, the dose delivered by the daily image setup process still without affect the dosimetric quality of the plans, and the dose distribution is acceptable achieving the protocol objectives.

Keywords: hypofrationation, VMAT, chestwall, radiotherapy planning

Procedia PDF Downloads 78
20184 The Anti-Obesity Effects of the Aqueous and Ethanolic Leaf Extracts of Blumea balsamifera on Diet-Induced Obese Sprague-Dawley Rats

Authors: Mae Genevieve G. Cheung, Michael G. Cuevas, Lovely Fe L. Cuison, Elijin P. Dai, Katrina Marie S. Duron, Azalea Damaris E. Encarnacion, May T. Magtoto, Gina C. Castro

Abstract:

The present study aims to evaluate the effectiveness of aqueous and ethanolic leaf extracts of Blumea balsamifera in reducing obesity on diet-induced obese Sprague-Dawley rats. Aqueous and ethanolic leaf extracts were obtained by maceration and percolation, respectively, of air-dried, grinded leaves. The test animals were given a high fat diet (HFD) for 21 days, except for one negative control group fed with a standard diet (SD). The Blumea balsamifera extracts were given at doses of 300 mg/Kg and 600 mg/Kg for BBAE and BBEE groups, and the positive control group, Orlistat, was given at 21.6 mg/Kg dose. After 24 days of treatment, the statistical difference of parameters such as Lee’s index and lipid profile of each group before and after the treatment period were determined separately using Tukey’s test of two-way Analysis of Variance (ANOVA). The statistical results showed that the600mg/kg dose of BBAE and BBEE had greatly lowered the Lee’s index among the other doses while the 300 mg/Kg dose BBEE, 600 mg/Kg BBAE, and 300 mg/kg BBAE lowered the total cholesterol level, LDL level, and VLDL and total triglyceride level respectively. The extracts, however, lowered the HDL level which was also exhibited by the standard drug, Orlistat.

Keywords: adipocytes, adipogenesis, Blumea balsamifera, Lee’s index, obesity, Sambong

Procedia PDF Downloads 340
20183 The Effects of Chamomile on Serum Levels of Inflammatory Indexes to a Bout of Eccentric Exercise in Young Women

Authors: K. Azadeh, M. Ghasemi, S. Fazelifar

Abstract:

Aim: Changes in stress hormones can be modify response of immune system. Cortisol as the most important body corticosteroid is anti-inflammatory and immunosuppressive hormone. Normal levels of cortisol in humans has fluctuated during the day, In other words, cortisol is released periodically, and regulate through the release of ACTH circadian rhythm in every day. Therefore, the aim of this study was to determine the effects of Chamomile on serum levels of inflammatory indexes to a bout of eccentric exercise in young women. Methodology: 32 women were randomly divided into 4 groups: high dose of Chamomile, low dose of Chamomile, ibuprofen and placebo group. Eccentric exercise included 5 set and rest period between sets was 1 minute. For this purpose, subjects warm up 10 min and then done eccentric exercise. Each participant completed 15 repetitions with optional 20 kg weight or until can’t continue moving. When the subject was no longer able to continue to move, immediately decreased 5 kg from the weight and the protocol continued until cause exhaustion or complete 15 repetitions. Also, subjects received specified amount of ibuprofen and Chamomile capsules in target groups. Blood samples in 6 stages (pre of starting pill, pre of exercise protocol, 4, 24, 48 and 72 hours after eccentric exercise) was obtained. The levels of cortisol and adrenocorticotropic hormone levels were measured by ELISA way. K-S test to determine the normality of the data and analysis of variance for repeated measures was used to analyze the data. A significant difference in the p < 0/05 accepted. Results: The results showed that Individual characteristics including height, weight, age and body mass index were not significantly different among the four groups. Analyze of data showed that cortisol and ACTH basic levels significantly decreased after supplementation consumption, but then gradually significantly increased in all stages of post exercise. In High dose of Chamomile group, increasing tendency of post exercise somewhat less than other groups, but not to a significant level. The inter-group analysis results indicate that time effect had a significant impact in different stages of the groups. Conclusion: The results of this study, one session of eccentric exercise increased cortisol and ACTH hormone. The results represent the effect of high dose of Chamomile in the prevention and reduction of increased stress hormone levels. As regards use of medicinal plants and ibuprofen as a pain medication and inflammation has spread among athletes and non-athletes, the results of this research can provide information about the advantages and disadvantages of using medicinal plants and ibuprofen.

Keywords: chamomile, inflammatory indexes, eccentric exercise, young girls

Procedia PDF Downloads 398
20182 Quality of Life and Self-Assessed Health of Methadone – Maintained Opiate Addicts

Authors: Brajevic-gizdic Igna, Vuletic Gorka

Abstract:

Introduction: Research in opiate addiction is increasingly indicating the importance of substitution therapy in opiate addicts. Opiate addiction is a chronic relapsing disease that includes craving as a criterion. Craving has been considered a predictor of a relapse, which is defined as a strong desire with an excessive need to take a substance. The study aimed to measure the intensity of craving using the VAS (visual analog scale) in opioid addicts taking the Opioid Substitution Therapy (OST). Method: The total sample compromised of 30 participants in outpatient treatment. Two groups of opiate addicts were considered: Methadone-maintenance and buprenorphine-maintenance addicts. The participants completed the survey questionnaire during the outpatient treatment. Results: The results indicated high levels of cravings in patients during the treatment on OST, which is considered an important destabilization factor in abstinence. Thus, the use of methadone/buprenorphine dose should be considered. Conclusion: These findings provided an objective measurement of methadone /buprenorphine dosage and therapy options. The underdoes of OST can put patients at high risk of relapse, resulting in high levels of craving. Thus, when determining the therapeutic dose of OST, it is crucial to consider patients´ craving. This would achieve stabilization more quickly and avoid relapse in abstinence. Subjective physician assessment and patient’s statement are the main criteria to determine OST dosage. Future studies should use larger sample sizes and focus on the importance of intensity craving measurement on OST to objectify methadone /buprenorphine dosage.

Keywords: abstinence, addicts, methadone, OST, quality of life

Procedia PDF Downloads 60
20181 Microfluidic Based High Throughput Screening System for Photodynamic Therapy against Cancer Cells

Authors: Rina Lee, Chung-Hun Oh, Eunjin Lee, Jeongyun Kim

Abstract:

The Photodynamic therapy (PDT) is a treatment that uses a photosensitizer as a drug to damage and kill cancer cells. After injecting the photosensitizer into the bloodstream, the drug is absorbed by cancer cells selectively. Then the area to be treated is exposed to specific wavelengths of light and the photosensitizer produces a form of oxygen that kills nearby cancer cells. PDT is has an advantage to destroy the tumor with minimized side-effects on normal cells. But, PDT is not a completed method for cancer therapy. Because the mechanism of PDT is quite clear yet and the parameters such as intensity of light and dose of photosensitizer are not optimized for different types of cancers. To optimize these parameters, we suggest a novel microfluidic system to automatically control intensity of light exposure with a personal computer (PC). A polydimethylsiloxane (PDMS) microfluidic chip is composed with (1) a cell culture channels layer where cancer cells were trapped to be tested with various dosed photofrin (1μg/ml used for the test) as the photosensitizer and (2) a color dye layer as a neutral density (ND) filter to reduce intensity of light which exposes the cell culture channels filled with cancer cells. Eight different intensity of light (10%, 20%, …, 100%) are generated through various concentrations of blue dye filling the ND filter. As a light source, a light emitting diode (LED) with 635nm wavelength was placed above the developed PDMS microfluidic chip. The total time for light exposure was 30 minutes and HeLa and PC3 cell lines of cancer cells were tested. The cell viability of cells was evaluated with a Live/Dead assay kit (L-3224, Invitrogen, USA). The stronger intensity of light exposed, the lower viability of the cell was observed, and vice versa. Therefore, this system was demonstrated through investigating the PDT against cancer cell to optimize the parameters as critical light intensity and dose of photosensitizer. Our results suggest that the system can be used for optimizing the combinational parameters of light intensity and photosensitizer dose against diverse cancer cell types.

Keywords: photodynamic therapy, photofrin, high throughput screening, hela

Procedia PDF Downloads 359
20180 Efficacy of Opicapone and Levodopa with Different Levodopa Daily Doses in Parkinson’s Disease Patients with Early Motor Fluctuations: Findings from the Korean ADOPTION Study

Authors: Jee-Young Lee, Joaquim J. Ferreira, Hyeo-il Ma, José-Francisco Rocha, Beomseok Jeon

Abstract:

The effective management of wearing-off is a key driver of medication changes for patients with Parkinson’s disease (PD) treated with levodopa (L-DOPA). While L-DOPA is well tolerated and efficacious, its clinical utility over time is often limited by the development of complications such as dyskinesia. Still, common first-line option includes adjusting the daily L-DOPA dose followed by adjunctive therapies usually counting for the L-DOPA equivalent daily dose (LEDD). The LEDD conversion formulae are a tool used to compare the equivalence of anti-PD medications. The aim of this work is to compare the effects of opicapone (OPC) 50 mg, a catechol-O-methyltransferase (COMT) inhibitor, and an additional 100 mg dose of L-DOPA in reducing the off time in PD patients with early motor fluctuations receiving different daily L-DOPA doses. OPC was found to be well tolerated and efficacious in advanced PD population. This work utilized patients' home diary data from a 4-week Phase 2 pharmacokinetics clinical study. The Korean ADOPTION study randomized (1:1) patients with PD and early motor fluctuations treated with up to 600 mg of L-DOPA given 3–4 times daily. The main endpoint was change from baseline in off time in the subgroup of patients receiving 300–400 mg/day L-DOPA at baseline plus OPC 50 mg and in the subgroup receiving >300 mg/day L-DOPA at baseline plus an additional dose of L-DOPA 100 mg. Of the 86 patients included in this subgroup analysis, 39 received OPC 50 mg and 47 L-DOPA 100 mg. At baseline, both L-DOPA total daily dose and LEDD were lower in the L-DOPA 300–400 mg/day plus OPC 50 mg group than in the L-DOPA >300 mg/day plus L-DOPA 100 mg. However, at Week 4, LEDD was similar between the two groups. The mean (±standard error) reduction in off time was approximately three-fold greater for the OPC 50 mg than for the L-DOPA 100 mg group, being -63.0 (14.6) minutes for patients treated with L-DOPA 300–400 mg/day plus OPC 50 mg, and -22.1 (9.3) minutes for those receiving L-DOPA >300 mg/day plus L-DOPA 100 mg. In conclusion, despite similar LEDD, OPC demonstrated a significantly greater reduction in off time when compared to an additional 100 mg L-DOPA dose. The effect of OPC appears to be LEDD independent, suggesting that caution should be exercised when employing LEDD to guide treatment decisions as this does not take into account the timing of each dose, onset, duration of therapeutic effect and individual responsiveness. Additionally, OPC could be used for keeping the L-DOPA dose as low as possible for as long as possible to avoid the development of motor complications which are a significant source of disability.

Keywords: opicapone, levodopa, pharmacokinetics, off-time

Procedia PDF Downloads 27
20179 FEDBD Plasma, A Promising Approach for Skin Rejuvenation

Authors: P. Charipoor, M. Khani, H. Mahmoudi, E. Ghasemi, P. Akbartehrani, B. Shokri

Abstract:

Cold air plasma could have a variety of effects on cells and living organisms and also shows good results in medical and cosmetic cases. Herein, plasma floating electrode dielectric barrier discharge (FEDBD) plasma was designed for mouse skin rejuvenation purposes. It is safe and easy to use in clinics, laboratories, and homes. The effects of this device were investigated on mouse skin. Vitamin C ointment in combination with plasma was also used as a new method to improve FEDBD results. In this study, 20 Wistar rats were evaluated in four groups. The first group received high-dose plasma, the second group received moderate-dose plasma (with vitamin C cream), the third group received low-dose plasma (with vitamin C cream) for 6 minutes, and the fourth group received only vitamin C cream. This process was done 3 times a week for 4 weeks. Skin temperature was monitored to evaluate the thermal effect of plasma. The presence of reactive species was also demonstrated using optical spectroscopy. Mechanical assays were performed to evaluate the effect of plasma and vitamin C on the mechanical strength of the tissue, which showed a positive effect of plasma on the treated tissue compared to the control group. Using pathological and biometric skin tests, an increase in collagen levels, epidermal thickness, and an increase in fibroblasts was observed in rat skin, as well as increased skin elasticity. This study showed the positive effect of using the FEDBD plasma device on the effective parameters in skin rejuvenation.

Keywords: plasma, skin rejuvenation, collagen, epidermal thickness

Procedia PDF Downloads 222
20178 Measurement of Blood Phenobarbital Concentration Within Newborns Admitted to the NICU of Imam Reza Hospital and Received the Drug by Intravenous Mode

Authors: Ahmad Shah Farhat, Anahita Alizadeh Qamsari, Ashraf Mohammadzadeh, Hamid Reza Goldouzian, Ezat Khodashenas

Abstract:

Introduction: Newborns may be treated with phenobarbital for many reasons. Because in each region, depending on different races and genetic factors, different pharmacokinetic conditions govern the drug. It is essential to control blood levels of certain drugs, especially phenobarbital, and maintain these levels during treatment. Methods: In this study, venous blood was collected from 50 neonates who received intravenous phenobarbital at a loading dose of 20 mg/kg weight and at least three days had passed since the maintenance dose of 5 mg/kg body weight. in 24 hours. and sent to the laboratory. Phenobarbital blood levels were measured, then the results were analyzed descriptively. Results: In this study, the average weight of newborns was 9.93 ± 2.58. The mean blood concentration of phenobarbital, three days after starting the maintenance dose in the group of infants weighing more than 2.5 kg, was 3.33 ± 9.1 micrograms/liter in the group of infants weighing less than 2 kg. and half a kilogram or LBW was 5.9 ± 9.5 micrograms/liter and in the group weighing less than 1.5 kg VLBW was 14.4 ± 15.46 micrograms/liter. There was no significant difference between groups (p>0.05). Three days after starting the maintenance dose in all three groups, the mean blood phenobarbital concentration was 9.86 ± 0.86 micrograms/liter. Conclusion: Blood phenobarbital levels in our newborns are below therapeutic levels, so phenobarbital levels should be evaluated.

Keywords: poisining, neonats, phenobarbital, drug

Procedia PDF Downloads 24
20177 Chemical Synthesis, Characterization and Dose Optimization of Chitosan-Based Nanoparticles of MCPA for Management of Broad-Leaved Weeds (Chenopodium album, Lathyrus aphaca, Angalis arvensis and Melilotus indica) of Wheat

Authors: Muhammad Ather Nadeem, Bilal Ahmad Khan, Tasawer Abbas

Abstract:

Nanoherbicides utilize nanotechnology to enhance the delivery of biological or chemical herbicides using combinations of nanomaterials. The aim of this research was to examine the efficacy of chitosan nanoparticles containing MCPA herbicide as a potential eco-friendly alternative for weed control in wheat crops. Scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), and ultraviolet absorbance were used to analyze the developed nanoparticles. The SEM analysis indicated that the average size of the particles was 35 nm, forming clusters with a porous structure. Both nanoparticles of fluroxyper + MCPA exhibited maximal absorption peaks at a wavelength of 320 nm. The compound fluroxyper +MCPA has a strong peak at a 2θ value of 30.55°, which correlates to the 78 plane of the anatase phase. The weeds, including Chenopodium album, Lathyrus aphaca, Angalis arvensis, and Melilotus indica, were sprayed with the nanoparticles while they were in the third or fourth leaf stage. There were seven distinct dosages used: doses (D0 (Check weeds), D1 (Recommended dose of traditional herbicide, D2 (Recommended dose of Nano-herbicide (NPs-H)), D3 (NPs-H with 05-fold lower dose), D4 ((NPs-H) with 10-fold lower dose), D5 (NPs-H with 15-fold lower dose), and D6 (NPs-H with 20-fold lower dose)). The chitosan-based nanoparticles of MCPA at the prescribed dosage of conventional herbicide resulted in complete death and visual damage, with a 100% fatality rate. The dosage that was 5-fold lower exhibited the lowest levels of plant height (3.95 cm), chlorophyll content (5.63%), dry biomass (0.10 g), and fresh biomass (0.33 g) in the broad-leaved weed of wheat. The herbicide nanoparticles, when used at a dosage 10-fold lower than that of conventional herbicides, had a comparable impact on the prescribed dosage. Nano-herbicides have the potential to improve the efficiency of standard herbicides by increasing stability and lowering toxicity.

Keywords: mortality, visual injury, chlorophyl contents, chitosan-based nanoparticles

Procedia PDF Downloads 23
20176 Impact of CYP3A5 Polymorphism on Tacrolimus to Predict the Optimal Initial Dose Requirements in South Indian Renal Transplant Recipients

Authors: S. Sreeja, Radhakrishnan R. Nair, Noble Gracious, Sreeja S. Nair, M. Radhakrishna Pillai

Abstract:

Background: Tacrolimus is a potent immunosuppressant clinically used for the long term treatment of antirejection of transplanted organs in liver and kidney transplant recipients though dose optimization is poorly managed. However, So far no study has been carried out on the South Indian kidney transplant patients. The objective of this study is to evaluate the potential influence of a functional polymorphism in CYP3A5*3 gene on tacrolimus physiological availability/dose ratio in South Indian renal transplant patients. Materials and Methods: Twenty five renal transplant recipients receiving tacrolimus were enrolled in this study. Their body weight, drug dosage, and therapeutic concentration of Tacrolimus were observed. All patients were on standard immunosuppressive regime of Tacrolimus-Mycophenolate mofetil along with steroids on a starting dose of Tac 0.1 mg/kg/day. CYP3A5 genotyping was performed by PCR followed with RFLP. Conformation of RFLP analysis and variation in the nucleotide sequence of CYP3A5*3 gene were determined by direct sequencing using a validated automated generic analyzer. Results: A significant association was found between tacrolimus per dose/kg/d and CYP3A5 gene (A6986G) polymorphism in the study population. The CYP3A5 *1/*1, *1/*3 and *3/*3 genotypes were detected in 5 (20 %), 5 (20 %) and 15 (60 %) of the 25 graft recipients, respectively. CYP3A5*3 genotypes were found to be a good predictor of tacrolimus Concentration/Dose ratio in kidney transplant recipients. Significantly higher L/D was observed among non-expressors 9.483 ng/mL(4.5- 14.1) as compared with the expressors 5.154 ng/mL (4.42-6.5 ) of CYP3A5. Acute rejection episodes were significantly higher for CYP3A5*1 homozygotes compared to patients with CYP3A5*1/*3 and CYP3A5*3/*3 genotypes (40 % versus 20 % and 13 %, respectively ). The dose normalized TAC concentration (ng/ml/mg/kg) was significantly lower in patients having CYP3A5*1/*3 polymorphism. Conclusion: This is the first study to extensively determine the effect of CYP3A5*3 genetic polymorphism on tacrolimus pharmacokinetics in South Indian renal transplant recipients and also shows that majority of our patients carry mutant allele A6986G in CYP3A5*3 gene. Identification of CYP3A5 polymorphism prior to transplantation could contribute to evaluate the appropriate initial dosage of tacrolimus for each patient.

Keywords: kidney transplant patients, CYP3A5 genotype, tacrolimus, RFLP

Procedia PDF Downloads 275
20175 Evaluation of Occupational Doses in Interventional Radiology

Authors: Fernando Antonio Bacchim Neto, Allan Felipe Fattori Alves, Maria Eugênia Dela Rosa, Regina Moura, Diana Rodrigues De Pina

Abstract:

Interventional Radiology is the radiology modality that provides the highest dose values to medical staff. Recent researches show that personal dosimeters may underestimate dose values in interventional physicians, especially in extremities (hands and feet) and eye lens. The aim of this work was to study radiation exposure levels of medical staff in different interventional radiology procedures and estimate the annual maximum numbers of procedures (AMN) that each physician could perform without exceed the annual limits of dose established by normative. For this purpose LiF:Mg,Ti (TLD-100) dosimeters were positioned in different body regions of the interventional physician (eye lens, thyroid, chest, gonads, hand and foot) above the radiological protection vests as lead apron and thyroid shield. Attenuation values for lead protection vests were based on international guidelines. Based on these data were chosen as 90% attenuation of the lead vests and 60% attenuation of the protective glasses. 25 procedures were evaluated: 10 diagnostics, 10 angioplasty, and 5-aneurysm treatment. The AMN of diagnostic procedures was 641 for the primary interventional radiologist and 930 for the assisting interventional radiologist. For the angioplasty procedures, the AMN for primary interventional radiologist was 445 and for assisting interventional radiologist was 1202. As for the procedures of aneurism treatment, the AMN for the primary interventional radiologist was 113 and for the assisting interventional radiologist were 215. All AMN were limited by the eye lens doses already considering the use of protective glasses. In all categories evaluated, the higher dose values are found in gonads and in the lower regions of professionals, both for the primary interventionist and for the assisting, but the eyes lens dose limits are smaller than these regions. Additional protections as mobile barriers, which can be positioned between the interventionist and the patient, can decrease the exposures in the eye lens, providing a greater protection for the medical staff. The alternation of professionals to perform each type of procedure can reduce the dose values received by them over a period. The analysis of dose profiles proposed in this work showed that personal dosimeters positioned in chest might underestimate dose values in other body parts of the interventional physician, especially in extremities and eye lens. As each body region of the interventionist is subject to different levels of exposure, dose distribution in each region provides a better approach to what actions are necessary to ensure the radiological protection of medical staff.

Keywords: interventional radiology, radiation protection, occupationally exposed individual, hemodynamic

Procedia PDF Downloads 353
20174 Dosimetric Dependence on the Collimator Angle in Prostate Volumetric Modulated Arc Therapy

Authors: Muhammad Isa Khan, Jalil Ur Rehman, Muhammad Afzal Khan Rao, James Chow

Abstract:

Purpose: This study investigates the dose-volume variations in planning target volume (PTV) and organs-at-risk (OARs) using different collimator angles for smart arc prostate volumetric modulated arc therapy (VMAT). Awareness of the collimator angle for PTV and OARs sparing is essential for the planner because optimization contains numerous treatment constraints producing a complex, unstable and computationally challenging problem throughout its examination of an optimal plan in a rational time. Materials and Methods: Single arc VMAT plans at different collimator angles varied systematically (0°-90°) were performed on a Harold phantom and a new treatment plan is optimized for each collimator angle. We analyzed the conformity index (CI), homogeneity index (HI), gradient index (GI), monitor units (MUs), dose-volume histogram, mean and maximum doses to PTV. We also explored OARs (e.g. bladder, rectum and femoral heads), dose-volume criteria in the treatment plan (e.g. D30%, D50%, V30Gy and V38Gy of bladder and rectum; D5%,V14Gy and V22Gy of femoral heads), dose-volume histogram, mean and maximum doses for smart arc VMAT at different collimator angles. Results: There was no significance difference found in VMAT optimization at all studied collimator angles. However, if 0.5% accuracy is concerned then collimator angle = 45° provides higher CI and lower HI. Collimator angle = 15° also provides lower HI values like collimator angle 45°. It is seen that collimator angle = 75° is established as a good for rectum and right femur sparing. Collimator angle = 90° and collimator angle = 30° were found good for rectum and left femur sparing respectively. The PTV dose coverage statistics for each plan are comparatively independent of the collimator angles. Conclusion: It is concluded that this study will help the planner to have freedom to choose any collimator angle from (0°-90°) for PTV coverage and select a suitable collimator angle to spare OARs.

Keywords: VMAT, dose-volume histogram, collimator angle, organs-at-risk

Procedia PDF Downloads 477
20173 Competitive Adsorption of Al, Ga and In by Gamma Irradiation Induced Pectin-Acrylamide-(Vinyl Phosphonic Acid) Hydrogel

Authors: Md Murshed Bhuyan, Hirotaka Okabe, Yoshiki Hidaka, Kazuhiro Hara

Abstract:

Pectin-Acrylamide- (Vinyl Phosphonic Acid) Hydrogels were prepared from their blend by using gamma radiation of various doses. It was found that the gel fraction of hydrogel increases with increasing the radiation dose reaches a maximum and then started decreasing with increasing the dose. The optimum radiation dose and the composition of raw materials were determined on the basis of equilibrium swelling which resulted in 20 kGy absorbed dose and 1:2:4 (Pectin:AAm:VPA) composition. Differential scanning calorimetry reveals the gel strength for using them as the adsorbent. The FTIR-spectrum confirmed the grafting/ crosslinking of the monomer on the backbone of pectin chain. The hydrogels were applied in adsorption of Al, Ga, and In from multielement solution where the adsorption capacity order for those three elements was found as – In>Ga>Al. SEM images of hydrogels and metal adsorbed hydrogels indicate the gel network and adherence of the metal ions in the interpenetrating network of the hydrogel which were supported by EDS spectra. The adsorption isotherm models were studied and found that the Langmuir adsorption isotherm model was well fitted with the data. Adsorption data were also fitted to different adsorption kinetic and diffusion models. Desorption of metal adsorbed hydrogels was performed in 5% nitric acid where desorption efficiency was found around 90%.

Keywords: hydrogel, gamma radiation, vinyl phosphonic acid, metal adsorption

Procedia PDF Downloads 127
20172 Testicular Dose and Associated Risk from Common Pelvis Radiation Therapy in Iran

Authors: Ahmad Shanei, Milad Baradaran-Ghahfarokhi

Abstract:

This study aimed to investigate testicular dose (TD) and the associated risk of heritable disease from common pelvis radiotherapy of male patients in Iran. In this work, the relation between TD and changes in beam energy, pelvis size, source to skin distance (SSD) and beam directions (anterior or posterior) were also evaluated. The values of TDs were measured on 67 randomly selected male patients during common pelvis radiotherapy using 1.17 and 1.33 MeV, Theratron Cobalt-60 unit at SSD of 80 cm and 9 MV, Neptun 10 PC and 18 MV, GE Saturne 20 at SSD of 100 cm at Seyed-Al Shohada Hospital, Isfahan, Iran. Results showed that the maximum TD was up to 12% of the tumor dose. Considering the risk factor for radiation-induced heritable disorders of 0.1% per Sv, an excess risk of hereditary disorders of 72 per 10000 births was conservatively calculated. There was a significant difference in the measured TD using different treatment machines and energies (P < 0.001). The TD at 100 cm SSD were much less than that for 80 cm SSD (P <0.001). The Pearson Correlation test showed that, as expected, there was a strong correlation between TD and patient’s pelvis size (r = 0.275, P <0.001). Using the student’s t-tests, it was found that, there was not a significant difference between TD and beam direction (P = 0.231). Iranian male patients undergoing pelvic radiotherapy have the potential of receiving a TD of more than 1 Gy which might result in temporary azoospermia. The risk for induction of hereditary disorders in future generations should be considered as low but not negligible in comparison with the correspondent nominal risk.

Keywords: pelvis radiotherapy, testicular dose, infertility, hereditary effects

Procedia PDF Downloads 516
20171 Monte Carlo Simulation of Pion Particles

Authors: Reza Reiazi

Abstract:

Attempts to verify Geant4 hadronic physic to transport antiproton beam using standard physics list have not reach to a reasonable results because of lack of reliable cross section data or non reliable model to predict the final states of annihilated particles. Since most of the antiproton annihilation energy is carried away by recoiling nuclear fragments which are result of pions interactions with surrounding nucleons, it should be investigated if the toolkit verified for pions. Geant4 version 9.4.6.p01 was used. Dose calculation was done using 700 MeV pions hitting a water tank applying standards physic lists. We conclude Geant4 standard physics lists to predict the depth dose of Pion minus beam is not same for all investigated models. Since the nuclear fragments will deposit their energy in a small distance, they are the most important source of dose deposition in the annihilation vertex of antiproton beams.

Keywords: Monte Carlo, Pion, simulation, antiproton beam

Procedia PDF Downloads 403
20170 Dynamic Conformal Arc versus Intensity Modulated Radiotherapy for Image Guided Stereotactic Radiotherapy of Cranial Lesion

Authors: Chor Yi Ng, Christine Kong, Loretta Teo, Stephen Yau, FC Cheung, TL Poon, Francis Lee

Abstract:

Purpose: Dynamic conformal arc (DCA) and intensity modulated radiotherapy (IMRT) are two treatment techniques commonly used for stereotactic radiosurgery/radiotherapy of cranial lesions. IMRT plans usually give better dose conformity while DCA plans have better dose fall off. Rapid dose fall off is preferred for radiotherapy of cranial lesions, but dose conformity is also important. For certain lesions, DCA plans have good conformity, while for some lesions, the conformity is just unacceptable with DCA plans, and IMRT has to be used. The choice between the two may not be apparent until each plan is prepared and dose indices compared. We described a deviation index (DI) which is a measurement of the deviation of the target shape from a sphere, and test its functionality to choose between the two techniques. Method and Materials: From May 2015 to May 2017, our institute has performed stereotactic radiotherapy for 105 patients treating a total of 115 lesions (64 DCA plans and 51 IMRT plans). Patients were treated with the Varian Clinac iX with HDMLC. Brainlab Exactrac system was used for patient setup. Treatment planning was done with Brainlab iPlan RT Dose (Version 4.5.4). DCA plans were found to give better dose fall off in terms of R50% (R50% (DCA) = 4.75 Vs R50% (IMRT) = 5.242) while IMRT plans have better conformity in terms of treatment volume ratio (TVR) (TVR(DCA) = 1.273 Vs TVR(IMRT) = 1.222). Deviation Index (DI) is proposed to better facilitate the choice between the two techniques. DI is the ratio of the volume of a 1 mm shell of the PTV and the volume of a 1 mm shell of a sphere of identical volume. DI will be close to 1 for a near spherical PTV while a large DI will imply a more irregular PTV. To study the functionality of DI, 23 cases were chosen with PTV volume ranged from 1.149 cc to 29.83 cc, and DI ranged from 1.059 to 3.202. For each case, we did a nine field IMRT plan with one pass optimization and a five arc DCA plan. Then the TVR and R50% of each case were compared and correlated with the DI. Results: For the 23 cases, TVRs and R50% of the DCA and IMRT plans were examined. The conformity for IMRT plans are better than DCA plans, with majority of the TVR(DCA)/TVR(IMRT) ratios > 1, values ranging from 0.877 to1.538. While the dose fall off is better for DCA plans, with majority of the R50%(DCA)/ R50%(IMRT) ratios < 1. Their correlations with DI were also studied. A strong positive correlation was found between the ratio of TVRs and DI (correlation coefficient = 0.839), while the correlation between the ratio of R50%s and DI was insignificant (correlation coefficient = -0.190). Conclusion: The results suggest DI can be used as a guide for choosing the planning technique. For DI greater than a certain value, we can expect the conformity for DCA plans to become unacceptably great, and IMRT will be the technique of choice.

Keywords: cranial lesions, dynamic conformal arc, IMRT, image guided radiotherapy, stereotactic radiotherapy

Procedia PDF Downloads 210