Search results for: Automated 3D Breast Ultrasound
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1896

Search results for: Automated 3D Breast Ultrasound

1686 MRI Compatible Fresnel Zone Plates made of Polylactic Acid

Authors: Daniel Tarrazó-Serrano, Sergio Pérez-López, Sergio Castiñeira-Ibáñez, Pilar Candelas, Constanza Rubio

Abstract:

Zone Plates (ZPs) are used in many areas of physics where planar fabrication is advantageous in comparison with conventional curved lenses. There are several types of ZPs, such as the well-known Fresnel ZPs or the more recent Fractal ZPs and Fibonacci ZPs. The material selection of the lens plays a very important role in the beam modulation control. This work presents a comparison between two Fresnel ZP made from different materials in the ultrasound domain: Polylactic Acid (PLA) and brass. PLA is the most common material used in commercial 3D-printers due to its high design flexibility and low cost. Numerical simulations based on Finite Element Method (FEM) and experimental results are shown, and they prove that the focusing capabilities of brass ZPs and PLA ZPs are similar. For this reason, PLA is proposed as a Magnetic Resonance Imaging (MRI) compatible material with great potential for therapeutic ultrasound focusing applications.

Keywords: FZP, PLA, focus, ultrasound, MRI

Procedia PDF Downloads 173
1685 Hyper Tuned RBF SVM: Approach for the Prediction of the Breast Cancer

Authors: Surita Maini, Sanjay Dhanka

Abstract:

Machine learning (ML) involves developing algorithms and statistical models that enable computers to learn and make predictions or decisions based on data without being explicitly programmed. Because of its unlimited abilities ML is gaining popularity in medical sectors; Medical Imaging, Electronic Health Records, Genomic Data Analysis, Wearable Devices, Disease Outbreak Prediction, Disease Diagnosis, etc. In the last few decades, many researchers have tried to diagnose Breast Cancer (BC) using ML, because early detection of any disease can save millions of lives. Working in this direction, the authors have proposed a hybrid ML technique RBF SVM, to predict the BC in earlier the stage. The proposed method is implemented on the Breast Cancer UCI ML dataset with 569 instances and 32 attributes. The authors recorded performance metrics of the proposed model i.e., Accuracy 98.24%, Sensitivity 98.67%, Specificity 97.43%, F1 Score 98.67%, Precision 98.67%, and run time 0.044769 seconds. The proposed method is validated by K-Fold cross-validation.

Keywords: breast cancer, support vector classifier, machine learning, hyper parameter tunning

Procedia PDF Downloads 40
1684 PCR Based DNA Analysis in Detecting P53 Mutation in Human Breast Cancer (MDA-468)

Authors: Debbarma Asis, Guha Chandan

Abstract:

Tumor Protein-53 (P53) is one of the tumor suppressor proteins. P53 regulates the cell cycle that conserves stability by preventing genome mutation. It is named so as it runs as 53-kilodalton (kDa) protein on Polyacrylamide gel electrophoresis although the actual mass is 43.7 kDa. Experimental evidence has indicated that P53 cancer mutants loses tumor suppression activity and subsequently gain oncogenic activities to promote tumourigenesis. Tumor-specific DNA has recently been detected in the plasma of breast cancer patients. Detection of tumor-specific genetic materials in cancer patients may provide a unique and valuable tumor marker for diagnosis and prognosis. Commercially available MDA-468 breast cancer cell line was used for the proposed study.

Keywords: tumor protein (P53), cancer mutants, MDA-468, tumor suppressor gene

Procedia PDF Downloads 449
1683 Enabling Non-invasive Diagnosis of Thyroid Nodules with High Specificity and Sensitivity

Authors: Sai Maniveer Adapa, Sai Guptha Perla, Adithya Reddy P.

Abstract:

Thyroid nodules can often be diagnosed with ultrasound imaging, although differentiating between benign and malignant nodules can be challenging for medical professionals. This work suggests a novel approach to increase the precision of thyroid nodule identification by combining machine learning and deep learning. The new approach first extracts information from the ultrasound pictures using a deep learning method known as a convolutional autoencoder. A support vector machine, a type of machine learning model, is then trained using these features. With an accuracy of 92.52%, the support vector machine can differentiate between benign and malignant nodules. This innovative technique may decrease the need for pointless biopsies and increase the accuracy of thyroid nodule detection.

Keywords: thyroid tumor diagnosis, ultrasound images, deep learning, machine learning, convolutional auto-encoder, support vector machine

Procedia PDF Downloads 20
1682 Ultrasound Guided Treatment of Carpal Tunnel Syndrome

Authors: Kazem Shakouri, Alireza Pishgahi, Homayoun Sadeghi-bBazargani, Shahla Dareshiri

Abstract:

Introduction: Carpal Tunnel Syndrome has numerous nonsurgical treatments including splint, physical therapy and corticosteroid injections. Aim: The purpose of this study was to evaluate the effectiveness of an ultrasound guided treatment procedure, for individuals with severe carpal tunnel syndrome. Materials and Method: 20 patients with an electrodiagnostic evidence of severe carpal tunnel syndrome were treated by an office-based ultrasound guided procedure (combination of percutaneous needle release of carpal tunnel and corticosteroid injection). Electrodiagnostic (nerve conduction study), clinical (Boston Carpal Tunnel Questionnaire, grip strength) and ultrasonic (median nerve and carpal tunnel cross-sectional area) measurements were recorded at baseline and one month after intervention. Results: Our preliminary data analysis showed that in one month follow up, patients had a significantly smaller cross-sectional area of the median nerve compared to pretreatment values (mean difference 0.06; 95%CI: 0.02-0.1; p < 0.001). In addition, patients had significantly less functional impairment (mean difference 35; 95% CI:28.7-43.4 ; p < 0.001), and an improved hand grip strength in one month follow up (mean difference 5.4; 95%CI: 3.1-7.8; p < 0.001;). There were no significant complications. Conclusion: Patients with severe carpal tunnel syndrome, who are candidates for surgical intervention, can consider office-based ultrasound guided needle release of carpal tunnel as an alternative safe treatment.

Keywords: Carpal Tunnel Syndrome, needle release, pain, ultrasound

Procedia PDF Downloads 217
1681 Developing a Health Literacy Questionnaire in Breast Cancer

Authors: Lida Moghaddam-Banaem, Mahmood Tavoosi, Soheila Khalili

Abstract:

Objective: The main objective of this study was designing a breast cancer health literacy questionnaire and assess its psychometric properties. Methods: A comprehensive literature review was performed to develop a primary questionnaire consisting of five domains. Qualitative and quantitative content validity were assessed by relevant experts, and after some modifications, the content validity index (CVI) and content validity ratio (CVR) were calculated. Qualitative and quantitative face validity were evaluated by a number of patients, and the impact score for each item was calculated. 225 women with breast cancer were asked to fill out the questionnaire and construct validity was determined by using exploratory factor analysis. The reliability was tested by Cronbach's alpha coefficient. Results: A 36-item questionnaire with five domains of reading, having access, understanding, assessing/judgment, and decision making/behavior was designed. 2 items were omitted in the qualitative content validity process. All items achieved optimum values in CVI, CVR and impact scores. Content and face validity of the questionnaire were confirmed too. According to the exploratory factor analysis, the five-factor solution accounted for 64.98 percent of the observed variance. Conclusion: Due to the obtained satisfactory validity and reliability, this tool can be used to assess health literacy in women with breast cancer. Health policy makers can use these findings for improving health-related behaviors in breast cancer patients.

Keywords: health literacy, breast cancer, questionnaire, psychometric properties

Procedia PDF Downloads 207
1680 Improvement of Microscopic Detection of Acid-Fast Bacilli for Tuberculosis by Artificial Intelligence-Assisted Microscopic Platform and Medical Image Recognition System

Authors: Hsiao-Chuan Huang, King-Lung Kuo, Mei-Hsin Lo, Hsiao-Yun Chou, Yusen Lin

Abstract:

The most robust and economical method for laboratory diagnosis of TB is to identify mycobacterial bacilli (AFB) under acid-fast staining despite its disadvantages of low sensitivity and labor-intensive. Though digital pathology becomes popular in medicine, an automated microscopic system for microbiology is still not available. A new AI-assisted automated microscopic system, consisting of a microscopic scanner and recognition program powered by big data and deep learning, may significantly increase the sensitivity of TB smear microscopy. Thus, the objective is to evaluate such an automatic system for the identification of AFB. A total of 5,930 smears was enrolled for this study. An intelligent microscope system (TB-Scan, Wellgen Medical, Taiwan) was used for microscopic image scanning and AFB detection. 272 AFB smears were used for transfer learning to increase the accuracy. Referee medical technicians were used as Gold Standard for result discrepancy. Results showed that, under a total of 1726 AFB smears, the automated system's accuracy, sensitivity and specificity were 95.6% (1,650/1,726), 87.7% (57/65), and 95.9% (1,593/1,661), respectively. Compared to culture, the sensitivity for human technicians was only 33.8% (38/142); however, the automated system can achieve 74.6% (106/142), which is significantly higher than human technicians, and this is the first of such an automated microscope system for TB smear testing in a controlled trial. This automated system could achieve higher TB smear sensitivity and laboratory efficiency and may complement molecular methods (eg. GeneXpert) to reduce the total cost for TB control. Furthermore, such an automated system is capable of remote access by the internet and can be deployed in the area with limited medical resources.

Keywords: TB smears, automated microscope, artificial intelligence, medical imaging

Procedia PDF Downloads 189
1679 Microwave Tomography: The Analytical Treatment for Detecting Malignant Tumor Inside Human Body

Authors: Muhammad Hassan Khalil, Xu Jiadong

Abstract:

Early detection through screening is the best tool short of a perfect treatment against the malignant tumor inside the breast of a woman. By detecting cancer in its early stages, it can be recognized and treated before it has the opportunity to spread and change into potentially dangerous. Microwave tomography is a new imaging method based on contrast in dielectric properties of materials. The mathematical theory of microwave tomography involves solving an inverse problem for Maxwell’s equations. In this paper, we present designed antenna for breast cancer detection, which will use in microwave tomography configuration.

Keywords: microwave imaging, inverse scattering, breast cancer, malignant tumor detection

Procedia PDF Downloads 328
1678 Ultra Wideband Breast Cancer Detection by Using SAR for Indication the Tumor Location

Authors: Wittawat Wasusathien, Samran Santalunai, Thanaset Thosdeekoraphat, Chanchai Thongsopa

Abstract:

This paper presents breast cancer detection by observing the specific absorption rate (SAR) intensity for identification tumor location, the tumor is identified in coordinates (x,y,z) system. We examined the frequency between 4-8 GHz to look for the most appropriate frequency. Results are simulated in frequency 4-8 GHz, the model overview include normal breast with 50 mm radian, 5 mm diameter of tumor, and ultra wideband (UWB) bowtie antenna. The models are created and simulated in CST Microwave Studio. For this simulation, we changed antenna to 5 location around the breast, the tumor can be detected when an antenna is close to the tumor location, which the coordinate of maximum SAR is approximated the tumor location. For reliable, we experiment by random tumor location to 3 position in the same size of tumor and simulation the result again by varying the antenna position in 5 position again, and it also detectable the tumor position from the antenna that nearby tumor position by maximum value of SAR, which it can be detected the tumor with precision in all frequency between 4-8 GHz.

Keywords: specific absorption rate (SAR), ultra wideband (UWB), coordinates, cancer detection

Procedia PDF Downloads 377
1677 Breast Cancer Mortality and Comorbidities in Portugal: A Predictive Model Built with Real World Data

Authors: Cecília M. Antão, Paulo Jorge Nogueira

Abstract:

Breast cancer (BC) is the first cause of cancer mortality among Portuguese women. This retrospective observational study aimed at identifying comorbidities associated with BC female patients admitted to Portuguese public hospitals (2010-2018), investigating the effect of comorbidities on BC mortality rate, and building a predictive model using logistic regression. Results showed that the BC mortality in Portugal decreased in this period and reached 4.37% in 2018. Adjusted odds ratio indicated that secondary malignant neoplasms of liver, of bone and bone marrow, congestive heart failure, and diabetes were associated with an increased chance of dying from breast cancer. Although the Lisbon district (the most populated area) accounted for the largest percentage of BC patients, the logistic regression model showed that, besides patient’s age, being resident in Bragança, Castelo Branco, or Porto districts was directly associated with an increase of the mortality rate.

Keywords: breast cancer, comorbidities, logistic regression, adjusted odds ratio

Procedia PDF Downloads 56
1676 Assessing Relationships between Glandularity and Gray Level by Using Breast Phantoms

Authors: Yun-Xuan Tang, Pei-Yuan Liu, Kun-Mu Lu, Min-Tsung Tseng, Liang-Kuang Chen, Yuh-Feng Tsai, Ching-Wen Lee, Jay Wu

Abstract:

Breast cancer is predominant of malignant tumors in females. The increase in the glandular density increases the risk of breast cancer. BI-RADS is a frequently used density indicator in mammography; however, it significantly overestimates the glandularity. Therefore, it is very important to accurately and quantitatively assess the glandularity by mammography. In this study, 20%, 30% and 50% glandularity phantoms were exposed using a mammography machine at 28, 30 and 31 kVp, and 30, 55, 80 and 105 mAs, respectively. The regions of interest (ROIs) were drawn to assess the gray level. The relationship between the glandularity and gray level under various compression thicknesses, kVp, and mAs was established by the multivariable linear regression. A phantom verification was performed with automatic exposure control (AEC). The regression equation was obtained with an R-square value of 0.928. The average gray levels of the verification phantom were 8708, 8660 and 8434 for 0.952, 0.963 and 0.985 g/cm3, respectively. The percent differences of glandularity to the regression equation were 3.24%, 2.75% and 13.7%. We concluded that the proposed method could be clinically applied in mammography to improve the glandularity estimation and further increase the importance of breast cancer screening.

Keywords: mammography, glandularity, gray value, BI-RADS

Procedia PDF Downloads 464
1675 Feedback of an Automated Hospital about the Performance of an Automated Drug Dispensing System’s Implementation

Authors: Bouami Hind, Millot Patrick

Abstract:

The implementation of automated devices in life-critical systems such as hospitals can bring a new set of challenges related to automation malfunctions. While automation has been identified as great leverage for the medication dispensing system’s security and efficiency, it also increases the complexity of the organization. In particular, the installation and operation stage of automated devices can be complex when malfunctions related to automated systems occur. This paper aims to document operators’ situation awareness about the malfunctions of automated drug delivery systems (ADCs) during their implementation through Saint Brieuc hospital’s feedback. Our evaluation approach has been deployed in Saint Brieuc hospital center’s pharmacy, which has been equipped with automated nominative drug dispensing systems since January of 2021. The analysis of Saint Brieuc hospital center pharmacy’s automation revealed numerous malfunctions related to the implementation of Automated Delivery Cabinets. It appears that the targeted performance is not reached in the first year of implementation in this case study. Also, errors have been collected in patients' automated treatments’ production such as lack of drugs in pill boxes or nominative carnets, excess of drugs, wrong location of the drug, drug blister damaged, non-compliant sachet, or ticket errors. Saint Brieuc hospital center’s pharmacy is doing a tremendous job of setting up and monitoring performance indicators from the beginning of automation and throughout ADC’s operation to control ADC’s malfunctions and meet the performance targeted by the hospital. Health professionals, including pharmacists, biomedical engineers and directors of work, technical services and safety, are heavily involved in an automation project. This study highlights the importance of the evaluation of ADCs’ performance throughout the implementation process and the hospital’s team involvement in automation supervision and management.

Keywords: life-critical systems, situation awareness, automated delivery cabinets, implementation, risks and malfunctions

Procedia PDF Downloads 71
1674 Contribution of Automated Early Warning Score Usage to Patient Safety

Authors: Phang Moon Leng

Abstract:

Automated Early Warning Scores is a newly developed clinical decision tool that is used to streamline and improve the process of obtaining a patient’s vital signs so a clinical decision can be made at an earlier stage to prevent the patient from further deterioration. This technology provides immediate update on the score and clinical decision to be taken based on the outcome. This paper aims to study the use of an automated early warning score system on whether the technology has assisted the hospital in early detection and escalation of clinical condition and improve patient outcome. The hospital adopted the Modified Early Warning Scores (MEWS) Scoring System and MEWS Clinical Response into Philips IntelliVue Guardian Automated Early Warning Score equipment and studied whether the process has been leaned, whether the use of technology improved the usage & experience of the nurses, and whether the technology has improved patient care and outcome. It was found the steps required to obtain vital signs has been significantly reduced and is used more frequently to obtain patient vital signs. The number of deaths, and length of stay has significantly decreased as clinical decisions can be made and escalated more quickly with the Automated EWS. The automated early warning score equipment has helped improve work efficiency by removing the need for documenting into patient’s EMR. The technology streamlines clinical decision-making and allows faster care and intervention to be carried out and improves overall patient outcome which translates to better care for patient.

Keywords: automated early warning score, clinical quality and safety, patient safety, medical technology

Procedia PDF Downloads 152
1673 Non-Destructive Testing of Selective Laser Melting Products

Authors: Luca Collini, Michele Antolotti, Diego Schiavi

Abstract:

At present, complex geometries within production time shrinkage, rapidly increasing demand, and high-quality standard requirement make the non-destructive (ND) control of additively manufactured components indispensable means. On the other hand, a technology gap and the lack of standards regulating the methods and the acceptance criteria indicate the NDT of these components a stimulating field to be still fully explored. Up to date, penetrant testing, acoustic wave, tomography, radiography, and semi-automated ultrasound methods have been tested on metal powder based products so far. External defects, distortion, surface porosity, roughness, texture, internal porosity, and inclusions are the typical defects in the focus of testing. Detection of density and layers compactness are also been tried on stainless steels by the ultrasonic scattering method. In this work, the authors want to present and discuss the radiographic and the ultrasound ND testing on additively manufactured Ti₆Al₄V and inconel parts obtained by the selective laser melting (SLM) technology. In order to test the possibilities given by the radiographic method, both X-Rays and γ-Rays are tried on a set of specifically designed specimens realized by the SLM. The specimens contain a family of defectology, which represent the most commonly found, as cracks and lack of fusion. The tests are also applied to real parts of various complexity and thickness. A set of practical indications and of acceptance criteria is finally drawn.

Keywords: non-destructive testing, selective laser melting, radiography, UT method

Procedia PDF Downloads 107
1672 Investigation p53 Codon 72 Polymorphism and miR-146a rs2910164 Polymorphism in Breast Cancer

Authors: Marjan Moradi Fard, Hossein Rassi, Masoud Houshmand

Abstract:

Aim: Breast cancer is one of the most common cancers affecting the morbidity and mortality of Iranian women. This disease is a result of collective alterations of oncogenes and tumor suppressor genes. Studies have produced conflicting results concerning the role of p53 codon 72 polymorphism (G>C) and miR-146a rs2910164 polymorphism (G>C) on the risk of several cancers; therefore, a research was performed to estimate the association between the p53 codon 72 polymorphism and miR-146a rs2910164 polymorphism in breast cancer. Methods and Materials: A total of 45 archival breast cancer samples from khatam hospital and 40 healthy samples were collected. Verification of each cancer reported in a relative was sought through the pathology reports of the hospital records. Then, DNA extracted from all samples by standard methods and p53 codon 72 polymorphism genotypes and miR-146a rs2910164 polymorphism genotypes were analyzed using multiplex PCR. The tubules, mitotic activity, necrosis, polymorphism and grade of breast cancer were staged by Nottingham histological grading and immunohistochemical staining of the sections from the paraffin wax embedded tissues for the expression of ER, PR and p53 was carried out using a standard method. Finally, data analysis was performed using the 7 version of the Epi Info(TM) 2012 software and test chi-square(x2) for trend. Results: Successful DNA extraction was assessed by PCR amplification of b-actin gene (99 bp). According to the results, p53 GG genotype and miR-146a rs2910164 CC genotype was significantly associated with increased risk of breast cancer in the study population. In this study, we established that tumors of p53 GG genotype and miR-146a rs2910164 CC genotype exhibited higher mitotic activity, higher polymorphism, lower necrosis, lower tubules, higher ER- and PR-negatives and lower TP53-positives than the other genotypes. Conclusion: The present study provided preliminary evidence that a p53 GG genotype may effect breast cancer risk in the study population, interacting synergistically with miR-146a rs2910164 CC genotype. Our results demonstrate that the testing of p53 codon 72 polymorphism genotypes and miR-146a rs2910164 polymorphism genotypes in combination with clinical parameters can serve as major risk factors in the early identification of breast cancers.

Keywords: breast cancer, p53 codon 72 polymorphism, miR-146a rs2910164 polymorphism, genotypes

Procedia PDF Downloads 311
1671 The Effectiveness of Laughing Qigong for Women with Breast Cancer in Community

Authors: Chueh Chang, Chia-jung Hsieh, Fu-yu Yu, Yu-Hwa Lin

Abstract:

Background:The majority of women diagnosed with breast cancer undergo treatment involving surgery and radiotherapy or chemotherapy, or both. With these major advances in breast cancer management, many patients still have to deal with short or long-term side effects and psychological distress related to the disease and treatment, which have a substantial impact on their quality of life. The Laughing Qigong Program (LQP) is an interactive laughter program that combines the physical and physiological benefits of laughter with the mental benefits of Chinese qigong. Purpose: In order to improve the quality of life for breast cancer women in the community as well as echoing the WHO 2004 “Promoting Mental Health” for every one. This study focused on how to promote the positive mental health for women of breast cancer through the “laughter program” in Taiwan. During the presentation, how to practice Laughing Qigong will be demonstrated. Method: Using nonequivalent pretest-posttest design, ix-one breast cancer patients were volunteered to enroll in this study from the Taiwan Breast Cancer Alliance (TBCA). Thirty patients were assigned to the experimental group and the other 31 patients were assigned to the control group. The women who were assigned to the experimental group received laughter program one hour per session, once a week, totally 12 sessions. All subjects were tested before and after the intervention on the following: Self-Esteem scale (RSE), Face Scale (FS), Anxiety and pain experience were measured as psychological markers; saliva cortisol (CS) as an immunological marker; blood pressure (BP), heart rate (HR),and heart rate variability (HRV) as physiological markers of the body’s response to stress. Results: After comparing the experimental and control groups, the results revealed that those breast cancer women with “laughing program” their sense of humor were improved, less uncomfortable on self report physical conditions, more positive attitudes toward stress management by using laughter, and had emotional improvement according to the face scale.

Keywords: mental health promotion, breast cancer, laughing Qigong, women

Procedia PDF Downloads 461
1670 Assessment of Kinetic Trajectory of the Median Nerve from Wrist Ultrasound Images Using Two Dimensional Baysian Speckle Tracking Technique

Authors: Li-Kai Kuo, Shyh-Hau Wang

Abstract:

The kinetic trajectory of the median nerve (MN) in the wrist has shown to be capable of being applied to assess the carpal tunnel syndrome (CTS), and was found able to be detected by high-frequency ultrasound image via motion tracking technique. Yet, previous study may not quickly perform the measurement due to the use of a single element transducer for ultrasound image scanning. Therefore, previous system is not appropriate for being applied to clinical application. In the present study, B-mode ultrasound images of the wrist corresponding to movements of fingers from flexion to extension were acquired by clinical applicable real-time scanner. The kinetic trajectories of MN were off-line estimated utilizing two dimensional Baysian speckle tracking (TDBST) technique. The experiments were carried out from ten volunteers by ultrasound scanner at 12 MHz frequency. Results verified from phantom experiments have demonstrated that TDBST technique is able to detect the movement of MN based on signals of the past and present information and then to reduce the computational complications associated with the effect of such image quality as the resolution and contrast variations. Moreover, TDBST technique tended to be more accurate than that of the normalized cross correlation tracking (NCCT) technique used in previous study to detect movements of the MN in the wrist. In response to fingers’ flexion movement, the kinetic trajectory of the MN moved toward the ulnar-palmar direction, and then toward the radial-dorsal direction corresponding to the extensional movement. TDBST technique and the employed ultrasound image scanner have verified to be feasible to sensitively detect the kinetic trajectory and displacement of the MN. It thus could be further applied to diagnose CTS clinically and to improve the measurements to assess 3D trajectory of the MN.

Keywords: baysian speckle tracking, carpal tunnel syndrome, median nerve, motion tracking

Procedia PDF Downloads 465
1669 Prognostic Value of Tumor Markers in Younger Patients with Breast Cancer

Authors: Lola T. Alimkhodjaeva, Lola T. Zakirova, Soniya S. Ziyavidenova

Abstract:

Background: Breast cancer occupies the first place among the cancer in women in the world. It is urgent today to study the role of molecular markers which are capable of predicting the dynamics and outcome of the disease. The aim of this study is to define the prognostic value of the content of estrogen receptor (ER), progesterone receptor (PgR), and amplification of HER-2 / neu oncoprotein by studying 3 and 5-year overall and relapse-free survival in 470 patients with primary operable and 280 patients with locally–advanced breast cancer. Materials and methods: Study results of 3 and 5-year overall and relapse-free survival, depending on the content of RE, PgR in primary operable patients showed that ER positive (+) and PgR (+) survival was 100 (96.2%) and 97.3 (94.6%), for ER negative (-) and PgR (-) - 69.2 (60.3%) and 65.4 (57.7%), for ER positive (+) and negative PgR (-) 87.4 (80.1%) and 81.5 (79.3%), for ER negative (-) and positive PgR (+) - 97.4 (93.4%) and 90.4 (88.5%), respectively. Survival results depended also on the level of HER-2 / neu expression. In patients with HER-2 / neu negative the survival rates were as follows: 98.6 (94.7%) and 96.2 (92.3%). In group of patients with the level of HER-2 / neu (2+) expression these figures were: 45.3 (44.3%) and 45.1 (40.2%), and in group of patients with the level of HER-2 / neu (3+) expression - 41.2 (33.1%) and 34.3 (29.4%). The combination of ER negative (-), PgR (-), HER-2 / neu (-) they were 27.2 (25.4%) and 19.5 (15.3%), respectively. In patients with locally-advanced breast cancer the results of 3 and 5-year OS and RFS for ER (+) and PgR (+) were 76.3 (69.3%) and 62.2 (61.4%), for ER (-) and RP (-) 29.1 (23.7%) and 18.3 (12.6%), for ER (+) and PgR (-) 61.2 (47.2%) and 39.4 (25.6%), for ER (-) and PgR (+) 54.3 (43.1%) and 41.3 (18.3%), respectively. The level of HER-2 / neu expression also affected the survival results. Therefore, in HER-2/ neu negative patients the survival rate was 74.1 (67.6%) and 65.1 (57.3%), with the level of expression (2+) 20.4 (14.2%) and 8.6 (6.4%), with the level of expression (3+) 6.2 (3.1%) and 1.2 (1.5%), respectively. The combination for ER, PgR, HER-2 / neu negative was 22.1 (14.3%) and 8.4 (1.2%). Conclusion: Thus, the presence of steroid hormone receptors in breast tumor tissues at primary operable and locally- advanced process as the lack of HER-2/neu oncoprotein correlates with the highest rates of 3- and 5-year overall and relapse-free survival. The absence of steroid hormone receptors as well as of HER-2/neu overexpression in malignant breast tissues significantly degrades the 3- and 5-year overall and relapse-free survival. Tumors with ER, PgR and HER-2/neu negative have the most unfavorable prognostics.

Keywords: breast cancer, estrogen receptor, oncoprotein, progesterone receptor

Procedia PDF Downloads 156
1668 Concentration of Zinc Micronutrients in Breast Milk Based on Determinant of Mother and Baby in Kassi-Kassi Health Center

Authors: Andi Tenri Ayu Rahman, Citrakesumasari, Devintha Virani

Abstract:

Breast milk is the complex biological fluid mix of macronutrient and micronutrient that are considered as perfect food for babies. Zinc has a role in various biological functions and physical growth. This research aims to know the average zinc (Zn) micronutrients content of breast milk by determinants of infant (birth weight) and mother (nutritional status and food intake) and description of the pattern of mothers breastfeeding. The type of research used is observational analytic with cross-sectional study design. The population was 41 mothers in Kassi-Kassi health center within one month. Sample research is mothers who gave birth at term and breastfed her baby. Sampling was done with random sampling technique involving 37 people. Samples of breast milk were analyzed in the laboratory by using the method of Atomic Absorption Spectrofotometry (AAS). This research find that from the samples (n=37) the average contents of zinc in the breast milk is 0,88±0,54 mg/L with the highest value on the group of low birth weight babies (1,13 ± 0,67mg/L), mothers who had normal nutritional status (0,981 ± 0,514 mg/L) and intake low zinc (0,94 ± 0,54 mg/L). Regarding breastfeeding pattern, 67,6% of the samples had had breastfeeding experience and 81,1% of breastfed more than eight times a day. In summary, the highest average value of the zinc content of breast milk was in the group of low birth weight babies, mother with normal nutritional status, and mothers having relatively low intake pattern.

Keywords: zinc, breastmilk, mother, baby

Procedia PDF Downloads 160
1667 Reliability of Social Support Measurement Modification of the BC-SSAS among Women with Breast Cancer Who Undergone Chemotherapy in Selected Hospital, Central Java, Indonesia

Authors: R. R. Dewi Rahmawaty Aktyani Putri, Earmporn Thongkrajai, Dedy Purwito

Abstract:

There were many instruments have been developed to assess social support which has the different dimension in breast cancer patients. The Issue of measurement is a challenge to determining the component of dimensional concept, defining the unit of measurement, and establishing the validity and reliability of the measurement. However, the instruments where need to know how much support which obtained and perceived among women with breast cancer who undergone chemotherapy which it can help nurses to prevent of non-adherence in chemotherapy. This study aimed to measure the reliability of BC-SSAS instrument among 30 Indonesian women with breast cancer aged 18 years and above who undergone chemotherapy for six cycles in the oncological unit of Outpatient Department (OPD), Margono Soekardjo Hospital, Central Java, Indonesia. Data were collected during October to December 2015 by using modified the Breast Cancer Social Support Assessment (BC-SSAS). The Cronbach’s alpha analysis was carried out to measure internal consistency for reliability test of BC-SSAS instrument. This study used five experts for content validity index. The results showed that for content validity, I-CVI was 0.98 and S-CVI was 0.98; Cronbach’s alpha value was 0.971 and the Cronbach’s alpha coefficients for the subscales were high, with 0.903 for emotional support, 0.865 for informational support, 0.901 for tangible support, 0.897 for appraisal support and 0.884 for positive interaction support. The results confirmed that the BC-SSAS instrument has high reliability. BC-SSAS instruments were reliable and can be used in health care services to measure the social support received and perceived among women with breast cancer who undergone chemotherapy so that preventive interventions can be developed and the quality of health services can be improved.

Keywords: BC-SSAS, women with breast cancer, chemotherapy, Indonesia

Procedia PDF Downloads 341
1666 Absorbed Dose Estimation of 177Lu-DOTATOC in Adenocarcinoma Breast Cancer Bearing Mice

Authors: S. Zolghadri, M. Mousavi-Daramoroudi, H. Yousefnia, F. Abbasi-Davani

Abstract:

In this study, the absorbed dose of human organs after injection of 177Lu-DOTATOC was studied based on the biodistribution of the complex in adenocarcinoma breast cancer bearing mice. For this purpose, the biodistribution of the radiolabelled complex was studied and compartmental modeling was applied to calculate the absorbed dose with high precision. As expected, 177Lu-DOTATOC illustrated a notable specific uptake in tumor and pancreas, organs with high level of somatostatin receptor on their surface and the effectiveness of the radio-conjugate for targeting of the breast adenocarcinoma tumors was indicated. The elicited results of modeling were the exponential equations, and those are utilized for obtaining the cumulated activity data by taking their integral. The results also exemplified that non-target absorbed-doses such as the liver, spleen and pancreas were approximately 0.008, 0.004, and 0.039, respectively. While these values were so much lower than target (tumor) absorbed-dose, it seems due to this low toxicity, this complex is a good agent for therapy.

Keywords: ¹⁷⁷Lu, breast cancer, compartmental modeling, dosimetry

Procedia PDF Downloads 121
1665 Prognostic Significance of Nuclear factor kappa B (p65) among Breast Cancer Patients in Cape Coast Teaching Hospital

Authors: Precious Barnes, Abraham Mensah, Leonard Derkyi-Kwarteng, Benjamin Amoani, George Adjei, Ernest Adankwah, Faustina Pappoe, Kwabena Dankwah, Daniel Amoako-Sakyi, Samuel Victor Nuvor, Dorcas Obiri-Yeboah, Ewura Seidu Yahaya, Patrick Kafui Akakpo, Roland Osei Saahene

Abstract:

Context: Breast cancer is a prevalent and aggressive type of cancer among African women, with high mortality rates in Ghana. Nuclear factor kappa B (NF-kB) is a transcription factor that has been associated with tumor progression in breast cancer. However, there is a lack of published data on NF-kB in breast cancer patients in Ghana or other African countries. Research Aim: The aim of this study was to assess the prognostic significance of NF-kB (p65) expression and its association with various clinicopathological features in breast cancer patients at the Cape Coast Teaching Hospital in Ghana. Methodology: A total of 90 formalin-fixed breast cancer tissues and 15 normal breast tissues were used in this study. The expression level of NF-kB (p65) was examined using immunohistochemical techniques. Correlation analysis between NF-kB (p65) expression and clinicopathological features was performed using SPSS version 25. Findings: The study found that NF-kB (p65) was expressed in 86.7% of breast cancer tissues. There was a significant relationship between NF-kB (p65) expression and tumor grade, proliferation index (Ki67), and molecular subtype. High-level expression of NF-kB (p65) was more common in tumor grade 3 compared to grade 1, and Ki67 > 20 had higher expression of NF-kB (p65) compared to Ki67 ≤ 20. Triple-negative breast cancer patients had the highest overexpression of NF-kB (p65) compared to other molecular subtypes. There was no significant association between NF-kB (p65) expression and other clinicopathological parameters. Theoretical Importance: This study provides important insights into the expression of NF-kB (p65) in breast cancer patients in Ghana, particularly in relation to tumor grade and proliferation index. The findings suggest that NF-kB (p65) could serve as a potential biological marker for cancer stage, progression, prognosis and as a therapeutic target. Data Collection and Analysis Procedures: Formalin-fixed breast cancer tissues and normal breast tissues were collected and analyzed using immunohistochemical techniques. Correlation analysis between NF-kB (p65) expression and clinicopathological features was performed using SPSS version 25. Question Addressed: This study addressed the question of the prognostic significance of NF-kB (p65) expression and its association with clinicopathological features in breast cancer patients in Ghana. Conclusion: This study, the first of its kind in Ghana, demonstrates that NF-kB (p65) is highly expressed among breast cancer patients at the Cape Coast Teaching Hospital, especially in triple-negative breast cancer patients. The expression of NF-kB (p65) is associated with tumor grade and proliferation index. NF-kB (p65) could potentially serve as a biological marker for cancer stage, progression, prognosis, and as a therapeutic target.

Keywords: breast cancer, Ki67, NF-kB (p65), tumor grade

Procedia PDF Downloads 33
1664 An Audit of Local Guidance Compliance For Stereotactic Core Biopsy For DCIS In The Breast Screening Programme

Authors: Aisling Eves, Andrew Pieri, Ross McLean, Nerys Forester

Abstract:

Background: The breast unit local guideline recommends that 12 cores should be used in a stereotactic-guided biopsy to diagnose DCIS. Twelve cores are regarded to provide good diagnostic value without removing more breast tissue than necessary. This study aimed to determine compliance with guidelines and investigated how the number of cores impacted upon the re-excision rate and size discrepancies. Methods: This single-centre retrospective cohort study of 72 consecutive breast screened patients with <15mm DCIS on radiological report underwent stereotactic-guided core biopsy and subsequent surgical excision. Clinical, radiological, and histological data were collected over 5 years, and ASCO guidelines for margin involvement of <2mm was used to guide the need for re-excision. Results: Forty-six (63.9%) patients had <12 cores taken, and 26 (36.1%) patients had ≥12 cores taken. Only six (8.3%) patients had 12 cores taken in their stereotactic biopsy. Incomplete surgical excision was seen in 17 patients overall (23.6%), and of these patients, twelve (70.6%) had fewer than 12 cores taken (p=0.55 for the difference between groups). Mammogram and biopsy underestimated the size of the DCIS in this subgroup by a median of 15mm (range: 6-135mm). Re-excision was required in 9 patients (12.5%), and five patients (6.9%) were found to have invasive ductal carcinoma on excision (80% had <12 cores, p=0.43). Discussion: There is poor compliance with the breast unit local guidelines and higher rates of re-excision in patients who did not have ≥12 cores taken. Taking ≥12 cores resulted in fewer missed invasive cancers lower incomplete excision and re-excision rates.

Keywords: stereotactic core biopsy, DCIS, breast screening, Re-excision rates, core biopsy

Procedia PDF Downloads 98
1663 Pale, Firm and Non-Exudative (PFN): An Emerging Major Broiler Breast Meat Group

Authors: Cintia Midori Kaminishikawahara, Fernanda Jéssica Mendonça, Moisés Grespan, Elza Iouko Ida, Massami Shimokomaki, Adriana Lourenço Soares

Abstract:

The quality of broiler breast meat is changing as a result of continuing emphasis on genetically bird’s selection for efficiently higher meat production. The consumer is experiencing a cooked product that is drier and less juicy when consumed. Breast meat has been classified as PSE (pale, soft, exudative), DFD (dark, firm, dry) and normal color meat. However, recently variations of this color have been observed and they are not in line with the specificity of the meat functional properties. Thus, the objective of this work was to report the finding of a new pale meat color group characterized as Pale, Firm and Non-exudative (PFN) based on its pH, color, meat functional properties and micro structural evaluation. Breast meat fillets samples (n=1045) from commercial line were classified into PSE (pH ≤5.8, L* ≥ 53.0), PFN (pH > 5.8 and L* ≥ 53.0) and Normal (pH >5.8 and L* < 53.0), based on pH and L* values. In sequence, a total of 30 samples of each group were analyzed for the water holding capacity (WHC) and shear force (SF). The incidence was 9.1% for PSE meat, 85.7% for PFN and 5.2% for Normal meat. The PSE meat presented lower values of WHC (P ≤ 0.05) followed in sequence by PFN and Normal samples and also the SF values of fresh PFN was higher than PSE meat (P ≤ 0.05) and similar to Normal samples. Under optical microscopy, the cell diameter was 10% higher for PFN in relation to PSE meat and similar to Normal meat. These preliminary results indicate an emerging group of breast meat and it should be considered that the Pale, Firm and Non-exudative should be considered as an ideal broiler breast meat quality.

Keywords: broiler PSE meat, light microscopy, texture, water holding capacity

Procedia PDF Downloads 311
1662 The Use of Ultrasound as a Safe and Cost-Efficient Technique to Assess Visceral Fat in Children with Obesity

Authors: Bassma A. Abdel Haleem, Ehab K. Emam, George E. Yacoub, Ashraf M. Salem

Abstract:

Background: Obesity is an increasingly common problem in childhood. Childhood obesity is considered the main risk factor for the development of metabolic syndrome (MetS) (diabetes type 2, dyslipidemia, and hypertension). Recent studies estimated that among children with obesity 30-60% will develop MetS. Visceral fat thickness is a valuable predictor of the development of MetS. Computed tomography and dual-energy X-ray absorptiometry are the main techniques to assess visceral fat. However, they carry the risk of radiation exposure and are expensive procedures. Consequently, they are seldom used in the assessment of visceral fat in children. Some studies explored the potential of ultrasound as a substitute to assess visceral fat in the elderly and found promising results. Given the vulnerability of children to radiation exposure, we sought to evaluate ultrasound as a safer and more cost-efficient alternative for measuring visceral fat in obese children. Additionally, we assessed the correlation between visceral fat and obesity indicators such as insulin resistance. Methods: A cross-sectional study was conducted on 46 children with obesity (aged 6–16 years). Their visceral fat was evaluated by ultrasound. Subcutaneous fat thickness (SFT), i.e., the measurement from the skin-fat interface to the linea alba, and visceral fat thickness (VFT), i.e., the thickness from the linea alba to the aorta, were measured and correlated with anthropometric measures, fasting lipid profile, homeostatic model assessment for insulin resistance (HOMA-IR) and liver enzymes (ALT). Results: VFT assessed via ultrasound was found to strongly correlate with the BMI, HOMA-IR with AUC for VFT as a predictor of insulin resistance of 0.858 and cut off point of >2.98. VFT also correlates positively with serum triglycerides and serum ALT. VFT correlates negatively with HDL. Conclusions: Ultrasound, a safe and cost-efficient technique, could be a useful tool for measuring the abdominal fat thickness in children with obesity. Ultrasound-measured VFT could be an appropriate prognostic factor for insulin resistance, hypertriglyceridemia, and elevated liver enzymes in obese children.

Keywords: metabolic syndrome, pediatric obesity, sonography, visceral fat

Procedia PDF Downloads 93
1661 New Quinazoline Derivative Induce Cytotoxic Effect against Mcf-7 Human Breast Cancer Cell

Authors: Maryam Zahedi Fard, Nazia Abdul Majid, Hapipah Mohd Ali, Mahmood Ameen Abdulla

Abstract:

New quinazoline schiff base 3-(5-bromo-2-hydroxy-3-methoxybenzylideneamino)-2-(5-bromo-2-hydroxy-3-methoxyphenyl)-2,3-dihydroquinazolin-4(1H)-one was investigated for anticancer activity against MCF-7 human breast cancer cell line with involved mechanism of apoptosis. The compound demonstrated a remarkable antiproliferative effect, with an IC50 value of 3.41 ± 0.34, after 72 hours of treatment. Morphological apoptotic features in treated MCF-7 cells were observed by AO/PI staining. Furthermore, treated MCF-7 cells subjected to apoptosis death, as exhibited by perturbation of mitochondrial membrane potential and cytochrome c release as well as increase in ROS generation. We also found activation of caspases 3/7 and -9. Moreover, acute toxicity test demonstrated the nontoxic nature of the compound in mice. Our results showed the selected compound significantly induce apoptosis in MCF-7 cells via intrinsic pathway, which might be considered as a potent candidate for further in vivo and clinical breast cancer studies.

Keywords: antiproliferative effect, MCF-7 human breast cancer cell line, apoptosis, caspases

Procedia PDF Downloads 501
1660 Fine Needle Aspiration Biopsy of Thyroid Nodules

Authors: Ilirian Laçi, Alketa Spahiu

Abstract:

Big strums of thyroid glandule observed by a simple viewing can be witnessed in everyday life. Medical cabinets evidence patients withpalpablenodes of thyroid glandule, mainly nodes of the size of 10 millimeters. Further, more cases which have resulted in negative under palpation have resulted in positive at ultrasound examination. Therefore, the use of ultrasound for diagnosing has increased the number of patients with nodes of thyroid glandule in the last couple of decades in all countries, Albania included. Thus, there has been evidence of an increased number of patients affected by this pathology, where female patients dominate. Demographically, the capital shows high numbers due to the high population, but of interest is the high incidence of those areas distanced from the sea. While regarding related pathologies, no significant link was evidenced, an element of ancestry was evident in the nodes of the thyroid glandule. When we talk of nodes of the thyroid glandule, we should consider hyperplasia, neoplasia, and inflammatory diseases that cause nodes of the thyroid glandule. This increase parallels the world’s increase of the incidence of thyroid glandule, with malign cases, which are at about 5% and are not depended on size. Given the numbers, with most thyroid glandule nodes being benign, the main objective of the examination of the nodes was the determination of benign and malign cases to avoid undue surgery. Subject of this study were 212 patients that underwent fine-needle aspiration (FNA) under ultrasound guidance at the Medical University Center of Tirana. All the patients came to the Mother Teresa University Hospital from public and private hospitals and other polyclinics. These patients had an ultrasound examination before visiting the Center of Nuclear Medicine for a scintigraph of thyroid glandule in the period September 2016 and September 2017. To correlate, all patients had been examined via ultrasound of the thyroid glandule prior to the scintigraph. The ultrasound included evaluation of the number of nodes, their size, their solid, cystic, or solid-cystic structure, echogenicity according to the gray scale, the presence of calcification, the presence of lymph nodes, the presence of adenopathy, and the correlation of the cytology results from the Laboratory of Pathological Anatomy of Medical University Center of Tirana.

Keywords: thyroid nodes, fine needle aspiration, ultrasound, scintigraphy

Procedia PDF Downloads 66
1659 TP53 Mutations in Molecular Subtypes of Breast Cancer in Young Pakistani Patients

Authors: Nadia Naseem, Farwa Batool, Nasir Mehmood, AbdulHannan Nagi

Abstract:

Background: The incidence and mortality of breast cancer vary significantly in geographically distinct populations. In Pakistan, breast cancer has shown an increase in incidence in young females and is characterized by more aggressive behavior. The tumor suppressor TP53 gene is a crucial genetic factor that plays a significant role in breast carcinogenesis. This study investigated the TP53 mutations in molecular subtypes of both nodes negative and positive breast cancer in young Pakistani patients. Material and Methods: p53, Estrogen Receptor (ER), Progesterone Receptor (PR), Her-2 neu and Ki 67 expressions were analyzed immunohistochemically in a series of 75 node negative (A) and 75 node positive (B) young (aged: 19-40 years) breast cancer patients diagnosed between 2014 to 2017 at two leading hospitals of Punjab, Pakistan. Tumor tissue specimens and peripheral blood samples were examined for TP53 mutations by direct sequencing of the gene (exons 4-9). The relation of TP53 mutations to these markers and clinicopathological data was investigated. Results: Mean age of the patients was 32.4 + 9.1 SD. Invasive breast carcinoma was the most frequent histological variant (A=92%, B=94.6%). Grade 3 carcinoma was the commonest grade (A=72%, B=81.3%). Triple negative cases (ER-, PR-, Her-2) formed most of the molecular subtypes (A=44%, B=50.6%). A total of 17.2% (A: 6.6%, B: 10.6%) patients showed TP53 mutations. Mutations were significantly more frequent in triple negative cases (A: 74.8%, B: 62.2%) compared to HER2-positive patients (P < 0.0001). In the multivariate analysis of the whole patient group, the independent prognosticator were triple negative cases (P=0.021), TP53 overexpression by IHC (P=0.001) and advanced-stage disease (P=0.007). No statistically significant correlation between TP53 mutations and clinicopathological parameters was found (P < 0.05). Conclusions: It is concluded that TP53 mutations are infrequently present in breast carcinoma of young Pakistani population and there was no significant correlation between p53 mutation and early onset disease. Immunohistochemically detected TP53 expression in our resource-constrained to set up can be beneficial in predicting mutations at the younger age in our population.

Keywords: immunohistochemistry (IHC), invasive breast carcinoma (IBC), Pakistan, TP53

Procedia PDF Downloads 132
1658 Up-Regulation of SCUBE2 Expression in Co-Cultures of Human Mesenchymal Stem Cell and Breast Cancer Cells

Authors: Hirowati Ali, Aisyah Ellyanti, Dewi Rusnita, Septelia Inawati Wanandi

Abstract:

Stem cell has been known for its potency to be differentiated in many cells. Recently stem cell has been used for many treatment of degenerative medicine. It is still controversy whether stem cell can be used for therapy or these cells can activate cancer stem cell. SCUBE2 is a novel secreted and membrane-anchored protein which has been reported to its role in better prognosis and inhibition of cancer cell proliferation. Our study aims to observe whether stem cell can up-regulate SCUBE2 gene in MCF7 breast cancer cell line. We used in vitro study using MCF-7 cell treated with stem cell derived from placenta Wharton's jelly which has been known for its stemness and widely used. Our results showed that MCF-7 cell line grows up rapidly in 6-well culture dish. Stem cell was cultured in 6-well dish. After 50%-60% MCF-7 confluence, we co-cultured these cells with stem cells for 24 hours and 48 hours. We hypothesize SCUBE2 gene which is previously known for its higher expression in better prognosis of breast cancer, is up-regulated after stem cells addition in MCF7 culture dishes.

Keywords: breast cancer cells, inhibition of cancer cells, mesenchymal stem cells, SCUBE2

Procedia PDF Downloads 309
1657 Serum 25-Hydroxyvitamin D Levels in Korean Breast Cancer Patients

Authors: Sung Yong Kim, Byung Joo Song

Abstract:

Background: Circulating 25-hydroxyvitamin D (25(OH)D) levels has been considered to be inversely related to breast cancer development, recurrence risk, and mortality. Mean vitamin D levels in Korean population is lower than western countries due to higher incidence of lactose intolerance and lower exposure to sunlight. The purpose of this study was to assess incidence of 25(OH)D deficiency at diagnosis and after adjuvant chemotherapy and to investigate the correlation serum 25(OH)D levels with clinicopathologic features. Methods: From December 2011 to October 2012, 280 breast cancer patients seen at a single tertiary cancer center were enrolled. Serum 25(OH)D was measured at the time of surgery and after completion of adjuvant chemotherapy. Statistical analyses used chi-square test, Fisher's exact test, t-test, and ANOVA. Results: Mean serum 25(OH)D was 18.5 ng/ml. The 25(OH)D levels were deficient (<20 ng/ml) in 190 patients (67.9%), insufficient (20-29 ng/ml) in 51 patients(18.2%), and sufficient (30-150 ng/ml) in 39 patients(13.9%). A notable decrease in 25(OH)D concentration was observed(p<0.001) after chemotherapy but was not related to chemotherapy regimens. It was found significant lower 25(OH)D levels at winter season(from October to March, p=0.030). Subjects with invasive carcinoma (IDC or ILC) had significantly lower circulating levels of 25(OH)D than those with ductal carcinoma in situ(DCIS) (p=0.010). Patients with larger tumor size tends to have lower serum 25(OH)D but there were no statistical significance. Conclusions: Most of the breast cancer patients showed deficient or insufficient serum 25(OH)D concentration. Incidence of vitamin D deficiency was higher in invasive carcinoma than DCIS. Serum 25(OH)D levels were decreased after chemotherapy. Consideration should be given to the supplement of vitamin D to those patients.

Keywords: breast neoplasms, vitamin D, Korean population, breast cancer

Procedia PDF Downloads 389