Search results for: high dose dosimetry
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 15035

Search results for: high dose dosimetry

14855 Determination of Natural Gamma Radioactivity in Sand along the Black Sea Coastal Region of Giresun, North Turkey

Authors: A. Karadeniz, Belgin Kucukomeroglu

Abstract:

In this study natural gamma radioactivity levels are determined on sands along the coastal regions of Giresun/Turkey. The coast of Giresun about 290 km long in investigated to collect 101 sand samples. Natural and artificial radioactivity concentrations of sand samples were measured by using HPGe gamma spectrometry. The average activity concentrations of 238U, 232Th, 40K and 137Cs on sand samples of Giresun were found to be 10.83±2.92 Bq/kg, 21.28±3.22 Bq/kg, 6.42±1.06 Bq/kg, 230.94±10.67 Bq/kg respectively. The average activity concentrations for these radionuclides were compared with the reported data of other parts of Turkey and other countries. The average absorbed dose rate for Giresun was calculated to be 38.68 nGy/h respectively. This value is significantly lower than the World averaged value of 60 nGy/h. The external annual effective dose rate concentration in Giresun was found to be 0.047 mSv/y respectively. This result is much lower than the recommeded limit of 5 mSv/y. The external hazard dose rate for Giresun weas calculated to be 0.21 respectively. This result is much lower than the recommended limit of 1.0.

Keywords: concentration, radioactivity, Giresun, natural gamma radioactivity

Procedia PDF Downloads 374
14854 Contrast-to-Noise Ratio Comparison of Different Calcification Types in Dual Energy Breast Imaging

Authors: Vaia N. Koukou, Niki D. Martini, George P. Fountos, Christos M. Michail, Athanasios Bakas, Ioannis S. Kandarakis, George C. Nikiforidis

Abstract:

Various substitute materials of calcifications are used in phantom measurements and simulation studies in mammography. These include calcium carbonate, calcium oxalate, hydroxyapatite and aluminum. The aim of this study is to compare the contrast-to-noise ratio (CNR) values of the different calcification types using the dual energy method. The constructed calcification phantom consisted of three different calcification types and thicknesses: hydroxyapatite, calcite and calcium oxalate of 100, 200, 300 thicknesses. The breast tissue equivalent materials were polyethylene and polymethyl methacrylate slabs simulating adipose tissue and glandular tissue, respectively. The total thickness was 4.2 cm with 50% fixed glandularity. The low- (LE) and high-energy (HE) images were obtained from a tungsten anode using 40 kV filtered with 0.1 mm cadmium and 70 kV filtered with 1 mm copper, respectively. A high resolution complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) X-ray detector was used. The total mean glandular dose (MGD) and entrance surface dose (ESD) from the LE and HE images were constrained to typical levels (MGD=1.62 mGy and ESD=1.92 mGy). On average, the CNR of hydroxyapatite calcifications was 1.4 times that of calcite calcifications and 2.5 times that of calcium oxalate calcifications. The higher CNR values of hydroxyapatite are attributed to its attenuation properties compared to the other calcification materials, leading to higher contrast in the dual energy image. This work was supported by Grant Ε.040 from the Research Committee of the University of Patras (Programme K. Karatheodori).

Keywords: calcification materials, CNR, dual energy, X-rays

Procedia PDF Downloads 331
14853 The Impact of Using Flattening Filter-Free Energies on Treatment Efficiency for Prostate SBRT

Authors: T. Al-Alawi, N. Shorbaji, E. Rashaidi, M.Alidrisi

Abstract:

Purpose/Objective(s): The main purpose of this study is to analyze the planning of SBRT treatments for localized prostate cancer with 6FFF and 10FFF energies to see if there is a dosimetric difference between the two energies and how we can increase the plan efficiency and reduce its complexity. Also, to introduce a planning method in our department to treat prostate cancer by utilizing high energy photons without increasing patient toxicity and fulfilled all dosimetric constraints for OAR (an organ at risk). Then toevaluate the target 95% coverage PTV95, V5%, V2%, V1%, low dose volume for OAR (V1Gy, V2Gy, V5Gy), monitor unit (beam-on time), and estimate the values of homogeneity index HI, conformity index CI a Gradient index GI for each treatment plan.Materials/Methods: Two treatment plans were generated for15 patients with localized prostate cancer retrospectively using the CT planning image acquired for radiotherapy purposes. Each plan contains two/three complete arcs with two/three different collimator angle sets. The maximum dose rate available is 1400MU/min for the energy 6FFF and 2400MU/min for 10FFF. So in case, we need to avoid changing the gantry speed during the rotation, we tend to use the third arc in the plan with 6FFF to accommodate the high dose per fraction. The clinical target volume (CTV) consists of the entire prostate for organ-confined disease. The planning target volume (PTV) involves a margin of 5 mm. A 3-mm margin is favored posteriorly. Organs at risk identified and contoured include the rectum, bladder, penile bulb, femoral heads, and small bowel. The prescription dose is to deliver 35Gyin five fractions to the PTV and apply constraints for organ at risk (OAR) derived from those reported in references. Results: In terms of CI=0.99, HI=0.7, and GI= 4.1, it was observed that they are all thesame for both energies 6FFF and 10FFF with no differences, but the total delivered MUs are much less for the 10FFF plans (2907 for 6FFF vs.2468 for 10FFF) and the total delivery time is 124Sc for 6FFF vs. 61Sc for 10FFF beams. There were no dosimetric differences between 6FFF and 10FFF in terms of PTV coverage and mean doses; the mean doses for the bladder, rectum, femoral heads, penile bulb, and small bowel were collected, and they were in favor of the 10FFF. Also, we got lower V1Gy, V2Gy, and V5Gy doses for all OAR with 10FFF plans. Integral dosesID in (Gy. L) were recorded for all OAR, and they were lower with the 10FFF plans. Conclusion: High energy 10FFF has lower treatment time and lower delivered MUs; also, 10FFF showed lower integral and meant doses to organs at risk. In this study, we suggest usinga 10FFF beam for SBRTprostate treatment, which has the advantage of lowering the treatment time and that lead to lessplan complexity with respect to 6FFF beams.

Keywords: FFF beam, SBRT prostate, VMAT, prostate cancer

Procedia PDF Downloads 64
14852 Oral Antibiotics in Trans-Rectal Prostate Biopsy and Its Efficacy to Reduce Infectious Complications: Systematic Review

Authors: Mohand Yaghi, O. Kehinde

Abstract:

Background: For the diagnosis of prostate cancer Trans-rectal prostate biopsy (TRPB) is used commonly, the procedure is associated with infective complications. There is evidence that antibiotics (ABx) decrease infective events after TRPB, but different regimens are used. Aim: To systematically review different regimens of prophylactic oral antibiotics in TRPB. Design: Medline, Embase, Clinical trials site, and Cochrane library were searched, experts were consulted about relevant studies. Randomized clinical trials (RCT) conducted in the last twenty years, which investigated different oral antibiotic regimens in TRPB, and compared their efficacy to reduce infectious complications were analyzed. Measurements: Primary outcomes were bacteriuria, urinary tract infection (UTI), fever, bacteremia, sepsis. Secondary outcomes were hospitalization rate, and the prevalence of ABx-resistant bacteria. Results: Nine trials were eligible with 3012 patients. Antibiotics prevented bacteriuria (3.5% vs. 9.88%), UTI (4.46% vs. 9.75%), and hospitalization (0.21% vs. 2.13%) significantly in comparison with placebo or no treatment. No significant difference was found in all outcomes of the review between the single dose regimen and the 3 days. The single dose regimen was as effective as the multiple dose except in Bacteriuria (6.75% vs. 3.25%), and the prevalence of ABx-resistant bacteria (1.57% vs. 0.27%). Quinolones reduced only UTI significantly in comparison with other antibiotics. Lastly, Ciprofloxacin is the best Quinolone to prevent UTI, and hospitalization. Conclusion: it is essential to prescribe prophylactic Antibiotics in TRPB. No conclusive evidence could be claimed about the superiority of the multiple or the 3 days regimens to the single dose regimen. Unexpectedly, ABx-resistant bacteria was identified more often in the single dose cohorts.

Keywords: infection, prostate cancer, sepsis, TRPB

Procedia PDF Downloads 350
14851 Estimation of Normalized Glandular Doses Using a Three-Layer Mammographic Phantom

Authors: Kuan-Jen Lai, Fang-Yi Lin, Shang-Rong Huang, Yun-Zheng Zeng, Po-Chieh Hsu, Jay Wu

Abstract:

The normalized glandular dose (DgN) estimates the energy deposition of mammography in clinical practice. The Monte Carlo simulations frequently use uniformly mixed phantom for calculating the conversion factor. However, breast tissues are not uniformly distributed, leading to errors of conversion factor estimation. This study constructed a three-layer phantom to estimated more accurate of normalized glandular dose. In this study, MCNP code (Monte Carlo N-Particles code) was used to create the geometric structure. We simulated three types of target/filter combinations (Mo/Mo, Mo/Rh, Rh/Rh), six voltages (25 ~ 35 kVp), six HVL parameters and nine breast phantom thicknesses (2 ~ 10 cm) for the three-layer mammographic phantom. The conversion factor for 25%, 50% and 75% glandularity was calculated. The error of conversion factors compared with the results of the American College of Radiology (ACR) was within 6%. For Rh/Rh, the difference was within 9%. The difference between the 50% average glandularity and the uniform phantom was 7.1% ~ -6.7% for the Mo/Mo combination, voltage of 27 kVp, half value layer of 0.34 mmAl, and breast thickness of 4 cm. According to the simulation results, the regression analysis found that the three-layer mammographic phantom at 0% ~ 100% glandularity can be used to accurately calculate the conversion factors. The difference in glandular tissue distribution leads to errors of conversion factor calculation. The three-layer mammographic phantom can provide accurate estimates of glandular dose in clinical practice.

Keywords: Monte Carlo simulation, mammography, normalized glandular dose, glandularity

Procedia PDF Downloads 168
14850 Rituximab Therapy for Musculoskeletal Involvement in Systemic Sclerosis

Authors: Liudmila Garzanova, Lidia Ananyeva, Olga Koneva, Olga Ovsyannikova, Oxana Desinova, Mayya Starovoytova, Rushana Shayahmetova, Anna Khelkovskaya-Sergeeva

Abstract:

Objectives. There is very few data on changes of the musculoskeletal manifestations (artritis, arthralgia, muscle weakness, etc.) in systemic sclerosis (SSc) on rituximab (RTX) therapy. The aim of our study was to assess the severity of the musculoskeletal involvement in SSc patients (pts) and its changes during RTX therapy. Methods. Our study included 103 pts with SSc. The mean followup period was 12.6±10.7 months. The mean age was 47±12.9 years, female-87 pts (84%), the diffuse cutaneous subset of the disease had 55 pts (53%). The mean disease duration was 6.2±5.5 years. All pts had interstitial lung disease (ILD) and were positive for ANA, 67% of them were positive for antitopoisomerase-1. All patients received prednisolone at a dose of 11.3±4.5 mg/day, immunosuppressants at inclusion received 47% of them. Pts received RTX due to the ineffectiveness of previous therapy for ILD. The cumulative mean dose of RTX was 1.7±0.6 grams. Arthritis was observed in 22 pts (21%), arthralgias in 47 pts (46%). Muscle weakness was observed in 17 pts (17%). Tendon friction rubs was established in 7 pts (7%). The results at baseline and at the end of the follow up are presented in the form of mean values. Results. There was an improvement of all outcome parameters and musculoskeletal manifestations on RTX therapy. There was a decrease in the number of pts with arthritis from 22 (21%) to 10 (9%), a decrease in the number of pts with arthralgias from 47 (46%) to 31 (30%). The number of pts with muscle weakness decreased from 17 (17%) to 7 (7%). The number of pts with tendon friction rubs decreased from 7 (7%) to 3 (3%). The creatine phosphokinase decreased from 365.5±186 to 70.8±50.4 (p=0.00006). The C-reactive protein (CRP) decreased from 23.2±31.3 to 8.62±7.4 (p=0.001). The dose of prednisolone was reduced from 11.3±4.5 to 9.8±3.5 mg/day (p=0.0004). Conclusion. In our study, musculoskeletal involvement was detected in almost half of the patients with SSc-ILD. There was an improvement of musculoskeletal manifestations despite a small cumulative dose of RTX. We also managed to reduce the dose of glucocorticosteroids. The improvement of musculoskeletal manifestations was accompanied by a decrease in laboratory parameters - creatine phosphokinase and CRP. RTX is effective option for treatment of musculoskeletal manifestations in SSc.

Keywords: arthritis, musculoskeletal involvement, systemic sclerosis, rituximab

Procedia PDF Downloads 63
14849 Genoprotective Effect of Lepidium sativum L. Seed Methanolic Extract on Cyclophosphamide-Induced DNA Damage in Mice and Characterization of Its Flavonoidal Content

Authors: Iman A. A. Kassem, Ayman A. Farghaly, Zeinab M. Hassan, Farouk R. Melek, Neveen S. Ghaly

Abstract:

Lipidium sativum L, an annual herb that grows to 50 cm, is known as an important member of family Brassicaceae. Besides its nutritional value, the seeds were widely used in folk medicine for treatment of cough, asthma, and headache. It was also reported to possess hypocholesterolemic, anti-inflammatory, antidiarrheal, antimicrobial and anticancer activities. In this study, the genoprotective properties of L. sativum seed methanolic extract (LSME) were evaluated in vivo. Three groups of mice were given LSME for five consecutive days at the three dose levels 25, 50 and 100 mg/kg b.wt. The three groups were then injected intraperitoneally with cyclophosphamide at a dose of 20 mg/kg b.wt. to induce DNA damage. A group received only cyclophosphamide (20 mg/kg b.wt.) served as control. LSME significantly inhibited the DNA aberrations in mice caused by cyclophosphamide in a dose-dependent manner in the two groups that received LSME at 50 and 100 mg/kg b.wt. dose levels. The chromosomal aberrations' inhibitory indices were calculated as 18 and 31 in mice bone marrow cells and 27 and 48 in mice spermatocytes, respectively. Phytochemical examination carried out by us revealed that flavonoids were the main chemical constituents of LSME. The major flavonoids kaempferol, kaempferol-3-O-rhamnoside, kaempferol-3-O-glucoside, quercetin, and quercetin-3-O-glucoside were isolated and characterized. It was concluded that the genoprotective effect of LSME might be attributed to the presence of flavonoids which are well-known for their antioxidant properties.

Keywords: cyclophosphamide, flavonoids, genoprotective effect, Lepidium sativum

Procedia PDF Downloads 130
14848 Efficacy of Single-Dose Azithromycin Therapy for the Treatment of Chlamydia trachomatis in Patients Evaluated for Child Sexual Abuse in an Urban Health Center 2006-16

Authors: Trenton Hubbard, Kenneth Soyemi, Emily Siffermann

Abstract:

Introduction: According to the American Academy of Pediatrics (AAP) there are different weight-based recommendations for the treatment of Chlamydia trachomatis (CT) in patients who are being evaluated for sexual assault. Current AAP Red Book guidelines recommend that uncomplicated C. trachomatis anogenital infection in prepubertal patients weighing less than =<45 kg be treated with oral erythromycin 50 mg/kg/day QID for 14 days with no alternative therapies, and for patients whose weight => 45 kg are Azithromycin 1 gm PO once. Our study objective was to determine the efficacy of single-dose Azithromycin therapy for the treatment of Chlamydia trachomatis in patients weighing less than 50 kg who were evaluated for child sexual abuse in an urban setting. Methods: We conducted a retrospective chart review of historical medical records (paper and electronic) patients weighing less than 50 kg who were evaluated for child sexual abuse and subsequently treated for C. trachomatis infection with Azithromycin (20 mg/kg PO once up to a maximum 1 gm) and received a Test of Cure (TOC) from 2006-2016. Qualitative variables were expressed as percentages. Quantitative variables were expressed as mean values (+/- standard deviation [SD]) if they followed a normal distribution or as median values (interquartile range[IQR]) if they did not. Wilcoxson two-sample test was used to compare means of Azithromycin Dose, mg/kg, and TOC timing between treatment responders and non-responders. Results: We reviewed records of 34 patients, average age (SD) was 5.4 (2.0) years, 33 (97%) were treated for CT and 1(3%) for both GC and CT. 25 (74%) were females. Urine PCR was the most commonly used test at evaluation and as TOC with 13 (38%) patients completing both tests. The average (SD) dose of Azithromycin at treatment was 470 (136) mg and average (SD) mg/kg dose of 20 (1.9) mg/kg for all patients. Median (IQR) timing for TOC testing was 19 (14-26) days. Of the 33 with complete data 25 (74%) had a negative TOC. When compared with treatment non-responders (TOC failures), treatment responders received higher doses (average dose (SD) received 495 (139) vs 401(110), P 0.06)); similar average (SD) weight base dosing received (20.8(2.0) vs 19.7 (1.5), P 0.15)), and earlier average (SD)TOC test timing (18.8 (5.6) vs 32 (28.6) P 0.02)). Conclusion: Azithromycin dosing appears to be efficacious in the treatment of CT post sexual assault as majority of patients responded. Although treatment responders and non-responders received similar weight based doses, there is need for additional studies to understand variances and predictors of response.

Keywords: child sexual abuse, chlmaydia trachmotis infection, single-dose azithromycin, weight less than or equal to 45 kilograms

Procedia PDF Downloads 268
14847 'Low Electronic Noise' Detector Technology in Computed Tomography

Authors: A. Ikhlef

Abstract:

Image noise in computed tomography, is mainly caused by the statistical noise, system noise reconstruction algorithm filters. Since last few years, low dose x-ray imaging became more and more desired and looked as a technical differentiating technology among CT manufacturers. In order to achieve this goal, several technologies and techniques are being investigated, including both hardware (integrated electronics and photon counting) and software (artificial intelligence and machine learning) based solutions. From a hardware point of view, electronic noise could indeed be a potential driver for low and ultra-low dose imaging. We demonstrated that the reduction or elimination of this term could lead to a reduction of dose without affecting image quality. Also, in this study, we will show that we can achieve this goal using conventional electronics (low cost and affordable technology), designed carefully and optimized for maximum detective quantum efficiency. We have conducted the tests using large imaging objects such as 30 cm water and 43 cm polyethylene phantoms. We compared the image quality with conventional imaging protocols with radiation as low as 10 mAs (<< 1 mGy). Clinical validation of such results has been performed as well.

Keywords: computed tomography, electronic noise, scintillation detector, x-ray detector

Procedia PDF Downloads 102
14846 Influence of Moringa Leaves Extract on the Response of Hb Molecule to Dose Rates’ Changes: II. Relaxation Time and Its Thermodynamic Driven State Functions

Authors: Mohamed M. M. Elnasharty, Azhar M. Elwan

Abstract:

Irradiation deposits energy through ionisation changing the bio-system’s net dipole, allowing the use of dielectric parameters and thermodynamic state functions related to these parameters as biophysical detectors to electrical inhomogeneity within the biosystem. This part is concerned with the effect of Moringa leaves extract, natural supplement, on the response of the biosystem to two different dose rates of irradiation. Having Hb molecule as a representative to the biosystem to be least invasive to the biosystem, dielectric measurements were used to extract the relaxation time of certain process found in the Hb spectrum within the indicated frequency window and the interrelated thermodynamic state functions were calculated from the deduced relaxation time. The results showed that relaxation time was decreased for both dose rates indicating a strong influence of Moringa on the response of biosystem and consequently Hb molecule. This influence was presented in the relaxation time and other parameters as well.

Keywords: activation energy, DC conductivity, dielectric relaxation, enthalpy change, Moringa leaves extract, relaxation time

Procedia PDF Downloads 122
14845 Gold Nanoparticle: Synthesis, Characterization, Clinico-Pathological, Pathological and Bio-Distribution Studies in Rabbits

Authors: M. M. Bashandy, A. R. Ahmed, M. El-Gaffary, Sahar S. Abd El-Rahman

Abstract:

This study evaluated the acute toxicity and tissue distribution of intravenously administered gold nanoparticles (AuNPs) in male rabbits. Rabbits were exposed to single dose of AuNPs (300 µg/ kg). Toxic effects were assessed via general behavior, hematological parameters, serum biochemical parameters and histopathological examination of various rabbits’ organs. Tissue distribution of AuNPs was evaluated at a dose of 300 µg/ kg in male rabbit. Inductively coupled plasma–mass spectrometry (ICP-MS) was used to determine gold concentrations in tissue samples collected at predetermined time intervals. After one week, AuNPs exerted no obvious acute toxicity in rabbits. However, inflammatory reactions in lung and liver cells were induced in rabbits treated at the300 µg/ kg dose level. The highest gold levels were found in the spleen, followed by liver, lungs and kidneys. These results indicated that AuNPs could be distributed extensively to various tissues in the body, but primarily in the spleen and liver.

Keywords: gold nanoparticles, toxicity, pathology, hematology, liver function, kidney function

Procedia PDF Downloads 312
14844 Assessment of Gamma Radiation Exposure of Soils Associated with Granitic Rocks in Kapıdağ Peninsula, Turkey

Authors: Buket Canbaz Öztürk, N. Füsun Çam, Günseli Yaprak, Osman Candan

Abstract:

The external terrestrial radiation exposure is related to the types of rock from which the soils originate. Higher radiation levels are associated with igneous rocks, such as granite, and lower levels with sedimentary rocks. Therefore, this study aims to assess the gamma radiation exposure of soils associated with granitic rocks in Kapıdağ Peninsula, Turkey. In the ongoing study, a comprehensive survey carried out systematically as a part of the environmental monitoring program on radiologic impact of the granitoid areas in Western Anatolia. The activity measurements of the gamma emitters (238U, 232Th and 40K) in the surface soil samples and the granitic rocks carried out by means of NaI(Tl) gamma-ray spectrometry system. To evaluate the radiological hazard of the natural radioactivity, the absorbed dose rate (D), the annual effective dose rate (AED), the radium equivalent activity (Raeq) and the external (Hex) hazard index were calculated according to the UNSCEAR 2000 report. The corresponding absorbed dose rates in air from all natural radionuclides were always much lower than 200 nGy h-1 and did not exceed the typical range of worldwide average values noticed in the UNSCEAR (2000) report. Furthermore, the correlation between soil and granitic rock samples were utilized, and external gamma radiation exposure distribution was mapped in Kapıdağ Peninsula.

Keywords: external absorbed dose, granitic rocks, Kapıdağ Peninsula, soil

Procedia PDF Downloads 209
14843 Calcitriol Improves Plasma Lipoprotein Profile by Decreasing Plasma Total Cholesterol and Triglyceride in Hypercholesterolemic Golden Syrian Hamsters

Authors: Xiaobo Wang, Zhen-Yu Chen

Abstract:

Higher plasma total cholesterol (TC) and low-density lipoprotein cholesterol (LDL-C) are independent risk factors of cardiovascular disease while high-density lipoprotein cholesterol (HDL-C) is protective. Vitamin D is well-known for its regulatory role in calcium homeostasis. Its potential important role in cardiovascular disease has recently attracted much attention. This study was conducted to investigate effects of different dosage of calcitriol on plasma lipoprotein profile and the underlying mechanism. Sixty male Syrian Golden hamsters were randomly divided into 6 groups: no-cholesterol control (NCD), high-cholesterol control (HCD), groups with calcitriol supplementation at 10/20/40/80ng/kg body weight (CA, CB, CC, CD), respectively. Calcitriol in medium-chain triacylglycerol (MCT) oil was delivered to four experimental groups via oral gavage every other day, while NCD and HCD received MCT oil in the equivalent amount. NCD hamsters were fed with non-cholesterol diet while other five groups were maintained on diet containing 0.2% cholesterol to induce a hypercholesterolemic condition. The treatment lasts for 6 weeks followed by sample collection after hamsters sacrificed. Four experimental groups experienced a reduction in average food intake around 11% compared to HCD with slight decrease in body weight (not exceeding 10%). This reduction reflects on the deceased relative weights of testis, epididymal and perirenal adipose tissue in a dose-dependent manner. Plasma calcitriol levels were measured and was corresponding to oral gavage. At the end of week 6, lipoprotein profiles were improved with calcitriol supplementation with TC, non-HDL-C and plasma triglyceride (TG) decreased in a dose-dependent manner (TC: r=0.373, p=0.009, non-HDL-C: r=0.479, p=0.001, TG: r=0.405, p=0.004). Since HDL-C of four experiment groups showed no significant difference compared to HCD, the ratio of nHDL-C to HDL-C and HDL-C to TC had been restored in a dose-dependent manner. For hamsters receiving the highest level of calcitriol (80ng/kg) showed a reduction of TC by 11.5%, nHDL-C by 24.1% and TG by 31.25%. Little difference was found among six groups on the acetylcholine-induced endothelium-dependent relaxation or contraction of thoracic aorta. To summarize, calcitriol supplementation in hamster at maximum 80ng/kg body weight for 6 weeks lead to an overall improvement in plasma lipoprotein profile with decreased TC and TG level. The molecular mechanism of its effects is under investigation.

Keywords: cholesterol, vitamin D, calcitriol, hamster

Procedia PDF Downloads 218
14842 Intrathecal Sufentanil or Fentanyl as Adjuvants to Low Dose Bupivacaine in Endoscopic Urological Procedures

Authors: Shikha Gupta, Suneet Kathuria, Supriya Sampley, Sunil Katyal

Abstract:

Opioids are being increasingly used these days as adjuvants to local anesthetics in spinal anesthesia. The aim of this prospective, randomized, double‑blind study is to compare the effects of adding sufentanil or fentanyl to low dose bupivacaine in spinal anesthesia for endoscopic urological procedures. A total of 90 elective endoscopic urological surgery patients, 40‑80 years old, received spinal anesthesia with 7.5 mg hyperbaric bupivacaine 0.5% (Group A) or by adding sufentanil 10 μg (Group B) or fentanyl 25 μg (Group C) to 5 mg hyperbaric bupivacaine 0.5%. These groups were compared in terms of the quality of spinal anesthesia as well as analgesia. Analysis of variance and Chi‑square test were used for Statistical analysis. The onset of sensory and motor blockade was significantly rapid in Group A as compared with Groups B and C. The maximum upper level of sensory block was higher in Group A patients than Groups B and C patients. Quality of analgesia was significantly better and prolonged in sufentanil group as compared with other two groups. Motor block was more intense and prolonged in Group A as compared with Groups B and C patients. Request for post‑operative analgesic was significantly delayed in Group B patients. Hence in conclusions, spinal anesthesia for endoscopic urological procedures in elderly patients using low dose bupivacaine (5 mg) combined with 10 μg sufentanil is associated with a lower incidence of hemodynamic instability, better quality and prolonged duration as compared to that by adding 25 μg fentanyl.

Keywords: adjuvants, bupivacaine, fentanyl, intrathecal, low dose spinal, sufentanil

Procedia PDF Downloads 357
14841 Dosimetric Comparison among Different Head and Neck Radiotherapy Techniques Using PRESAGE™ Dosimeter

Authors: Jalil ur Rehman, Ramesh C. Tailor, Muhammad Isa Khan, Jahnzeeb Ashraf, Muhammad Afzal, Geofferry S. Ibbott

Abstract:

Purpose: The purpose of this analysis was to investigate dose distribution of different techniques (3D-CRT, IMRT and VMAT) of head and neck cancer using 3-dimensional dosimeter called PRESAGETM Dosimeter. Materials and Methods: Computer tomography (CT) scans of radiological physics center (RPC) head and neck anthropomorphic phantom with both RPC standard insert and PRESAGETM insert were acquired separated with Philipp’s CT scanner and both CT scans were exported via DICOM to the Pinnacle version 9.4 treatment planning system (TPS). Each plan was delivered twice to the RPC phantom first containing the RPC standard insert having TLD and film dosimeters and then again containing the Presage insert having 3-D dosimeter (PRESAGETM) by using a Varian True Beam linear accelerator. After irradiation, the standard insert including point dose measurements (TLD) and planar Gafchromic® EBT film measurement were read using RPC standard procedure. The 3D dose distribution from PRESAGETM was read out with the Duke Midsized optical scanner dedicated to RPC (DMOS-RPC). Dose volume histogram (DVH), mean and maximal doses for organs at risk were calculated and compared among each head and neck technique. The prescription dose was same for all head and neck radiotherapy techniques which was 6.60 Gy/friction. Beam profile comparison and gamma analysis were used to quantify agreements among film measurement, PRESAGETM measurement and calculated dose distribution. Quality assurances of all plans were performed by using ArcCHECK method. Results: VMAT delivered the lowest mean and maximum doses to organ at risk (spinal cord, parotid) than IMRT and 3DCRT. Such dose distribution was verified by absolute dose distribution using thermoluminescent dosimeter (TLD) system. The central axial, sagittal and coronal planes were evaluated using 2D gamma map criteria(± 5%/3 mm) and results were 99.82% (axial), 99.78% (sagital), 98.38% (coronal) for VMAT plan and found the agreement between PRESAGE and pinnacle was better than IMRT and 3D-CRT plan excludes a 7 mm rim at the edge of the dosimeter. Profile showed good agreement for all plans between film, PRESAGE and pinnacle and 3D gamma was performed for PTV and OARs, VMAT and 3DCRT endow with better agreement than IMRT. Conclusion: VMAT delivered lowered mean and maximal doses to organs at risk and better PTV coverage during head and neck radiotherapy. TLD, EBT film and PRESAGETM dosimeters suggest that VMAT was better for the treatment of head and neck cancer than IMRT and 3D-CRT.

Keywords: RPC, 3DCRT, IMRT, VMAT, EBT2 film, TLD, PRESAGETM

Procedia PDF Downloads 365
14840 Interaction between NiCl2 and Selenium on Energy Profiles in Wistar albino Preimplanted Rats

Authors: O. Adjroud

Abstract:

The present study was conducted to investigate the interaction between selenium (Se) and chloride nickel (NiCl2) on energy profiles in Wistar albino preimplanted rats. NiCl2 was given on day 3 of pregnancy either in distilled drinking water at a dose of 20 mg/L/day for 16 consecutive days or as a single subcutaneous (s.c.) dose of 25, 50, or 100 mg/kg. Se was given as a s.c. injection (0.3 mg/kg) together with the higher dose (100 mg/kg) of NiCl2. Changes in energy profiles were evaluated in treated and control groups on days 5 and 20 of gestation. NiCl2 s.c. induced a significant increase in plasma glucose on day 20 of pregnancy. NiCl2 s.c. induced on day 5 and 20 of gestation a significant decrease in plasma triglycerides, with the higher dose. This decrease was maintained at day 20 of gestation with doses of 50 mg /kg. In addition, NiCl2 s.c. caused on day 5 of gestation a significant decrease in plasma total cholesterol with the low and medium doses. The pretreatment with Se reversed the effects of NiCl2 on plasma glucose, total cholesterol and triglycerides levels. NiCl2 administered in the drinking water augmented significantly the plasma triglycerides and total cholesterol levels and slighty the plasma glucose on day 20 of gestation, while on day 5 of gestation NiCl2 s.c. Induced a significant decrease in cholesterol. Three doses of NiCl2 (sc) induced severe alterations in liver and architecture which are markedly improved by Selenium. These results suggested that selenium has protective effects on energy profiles against the toxicity induced by NiCl2 administered subcutaneously in preimplanted rats.

Keywords: hepatotoxicity, nickel chloride, preimplanted rat, biochemical parameters

Procedia PDF Downloads 393
14839 Audit of TPS photon beam dataset for small field output factors using OSLDs against RPC standard dataset

Authors: Asad Yousuf

Abstract:

Purpose: The aim of the present study was to audit treatment planning system beam dataset for small field output factors against standard dataset produced by radiological physics center (RPC) from a multicenter study. Such data are crucial for validity of special techniques, i.e., IMRT or stereotactic radiosurgery. Materials/Method: In this study, multiple small field size output factor datasets were measured and calculated for 6 to 18 MV x-ray beams using the RPC recommend methods. These beam datasets were measured at 10 cm depth for 10 × 10 cm2 to 2 × 2 cm2 field sizes, defined by collimator jaws at 100 cm. The measurements were made with a Landauer’s nanoDot OSLDs whose volume is small enough to gather a full ionization reading even for the 1×1 cm2 field size. At our institute the beam data including output factors have been commissioned at 5 cm depth with an SAD setup. For comparison with the RPC data, the output factors were converted to an SSD setup using tissue phantom ratios. SSD setup also enables coverage of the ion chamber in 2×2 cm2 field size. The measured output factors were also compared with those calculated by Eclipse™ treatment planning software. Result: The measured and calculated output factors are in agreement with RPC dataset within 1% and 4% respectively. The large discrepancies in TPS reflect the increased challenge in converting measured data into a commissioned beam model for very small fields. Conclusion: OSLDs are simple, durable, and accurate tool to verify doses that delivered using small photon beam fields down to a 1x1 cm2 field sizes. The study emphasizes that the treatment planning system should always be evaluated for small field out factors for the accurate dose delivery in clinical setting.

Keywords: small field dosimetry, optically stimulated luminescence, audit treatment, radiological physics center

Procedia PDF Downloads 304
14838 Plasma Selenium Concentration and Polymorphism of Selenoprotein and Prostate Cancer

Authors: Yu-Mei Hsueh, Cheng-Shiuan Tsai, Chao-Yuan Huang

Abstract:

Prostate Cancer (PC) is a malignant tumor originated in prostate and is a second common male’s cancer in the world. Incidence of PC in Asia countries, have still been rising over the past few decades. As an antioxidant, selenium can slow down prostate cancer tumor progression, but the association between plasma selenium levels and risk of aggressive prostate cancer may be modified by different genotype of selenoprotein. The aim of this study is to determine the relationship between plasma selenium, polymorphism of selenoprotein, urinaty total arsenic, and prostate cancer. Two hundred ninety five pathologically-confirmed cases of PC and 295 cancer-free controls were individually matched to case subjects by age (± 5 years) were recruited from Department of Urology of National Taiwan University Hospital, Taipei Municipal Wan Fang Hospital and Taipei Medical University Hospital. Personal interview and biospeciment of urine and blood collection from participants were conducted by well-trained interviewers after participants’ informed consent was obtained. Plasma selenium was measured by an inductively coupled plasma mass. Urinary arsenic concentration was detected using high-performance liquid chromatography-linked hydride generator and atomic absorption spectrometry. The polymorphism of SEPP1rs3797310 and SEP15 rs5859 were determined using polymerase chain reaction-restriction fragment length polymorphism method. The higher plasma selenium was the lower OR of PC with a dose-response relationship. Prostate cancer patients with high plasma selenium had low tumor stage and grade. Participants carried SEPP1rs3797310 CT+TT genotype compared to those with CC genotype had a lower OR of PC in crude model; then this relationship was disappeared after confounder was adjusted. Prostate cancer patients with high urinary total arsenic concentration had high tumor stage and grade. Urinary total arsenic concentration was significantly positively related with plasma selenium and prostate specific antigen concentration. Participants with lower plasma selenium concentration and higher urinary total arsenic concentration compared to those with higher plasma selenium concentration and lower urinary total arsenic concentration had a higher OR of PC with a dose-response relationship.

Keywords: prostate cancer, plasma selenium concentration, urinary arsenic concentration, prostate specific antigen

Procedia PDF Downloads 453
14837 Removal of Vanadium from Industrial Effluents by Natural Ion Exchanger

Authors: Shashikant R. Kuchekar, Haribhau R. Aher, Priti M. Dhage

Abstract:

The removal vanadium from aqueous solution using natural exchanger was investigated. The effects of pH, contact time and exchanger dose were studied at ambient temperature (25 0C ± 2 0C). The equilibrium process was described by the Langmuir isotherm model with adsorption capacity for vanadium. The natural exchanger i.e. tamarindus seeds powder was treated with formaldehyde and sulpuric acid to increase the adsorptivity of metals. The maximum exchange level was attained as 80.1% at pH 3 with exchanger dose 5 g and contact time 60 min. Method is applied for removal of vanadium from industrial effluents.

Keywords: industrial effluent, natural ion exchange, Tamarindous indica, vanadium

Procedia PDF Downloads 224
14836 The Monitor for Neutron Dose in Hadrontherapy Project: Secondary Neutron Measurement in Particle Therapy

Authors: V. Giacometti, R. Mirabelli, V. Patera, D. Pinci, A. Sarti, A. Sciubba, G. Traini, M. Marafini

Abstract:

The particle therapy (PT) is a very modern technique of non invasive radiotherapy mainly devoted to the treatment of tumours untreatable with surgery or conventional radiotherapy, because localised closely to organ at risk (OaR). Nowadays, PT is available in about 55 centres in the word and only the 20\% of them are able to treat with carbon ion beam. However, the efficiency of the ion-beam treatments is so impressive that many new centres are in construction. The interest in this powerful technology lies to the main characteristic of PT: the high irradiation precision and conformity of the dose released to the tumour with the simultaneous preservation of the adjacent healthy tissue. However, the beam interactions with the patient produce a large component of secondary particles whose additional dose has to be taken into account during the definition of the treatment planning. Despite, the largest fraction of the dose is released to the tumour volume, a non-negligible amount is deposed in other body regions, mainly due to the scattering and nuclear interactions of the neutrons within the patient body. One of the main concerns in PT treatments is the possible occurrence of secondary malignant neoplasm (SMN). While SMNs can be developed up to decades after the treatments, their incidence impacts directly life quality of the cancer survivors, in particular in pediatric patients. Dedicated Treatment Planning Systems (TPS) are used to predict the normal tissue toxicity including the risk of late complications induced by the additional dose released by secondary neutrons. However, no precise measurement of secondary neutrons flux is available, as well as their energy and angular distributions: an accurate characterization is needed in order to improve TPS and reduce safety margins. The project MONDO (MOnitor for Neutron Dose in hadrOntherapy) is devoted to the construction of a secondary neutron tracker tailored to the characterization of that secondary neutron component. The detector, based on the tracking of the recoil protons produced in double-elastic scattering interactions, is a matrix of thin scintillating fibres, arranged in layer x-y oriented. The final size of the object is 10 x 10 x 20 cm3 (squared 250µm scint. fibres, double cladding). The readout of the fibres is carried out with a dedicated SPAD Array Sensor (SBAM) realised in CMOS technology by FBK (Fondazione Bruno Kessler). The detector is under development as well as the SBAM sensor and it is expected to be fully constructed for the end of the year. MONDO will make data tacking campaigns at the TIFPA Proton Therapy Center of Trento, at the CNAO (Pavia) and at HIT (Heidelberg) with carbon ion in order to characterize the neutron component and predict the additional dose delivered on the patients with much more precision and to drastically reduce the actual safety margins. Preliminary measurements with charged particles beams and MonteCarlo FLUKA simulation will be presented.

Keywords: secondary neutrons, particle therapy, tracking detector, elastic scattering

Procedia PDF Downloads 208
14835 Induction of Labor Using Misoprostol with or without Mifepristone in Intrauterine Death: A Randomized Controlled Study

Authors: Ajay Agrawal, Pritha Basnet, Achala Thakur, Pappu Rizal, Rubina Rai

Abstract:

Context: Rapid expulsion of fetus in intrauterine fetal death (IUFD) is usually requested without any medical grounds for it. So; an efficient, safe method for induction of labor (IOL) is required. Objective: To determine if pre-treatment with mifepristone followed by IOL with misoprostol in late IUFD is more efficacious. Methods: We conducted a randomized controlled trial in 100 patients. Group-A women received single oral dose of 200 mg mifepristone, followed by induction with vaginal misoprostol after 24-hour. Group-B women were induced only with vaginal misoprostol. In each group 5 dose of misoprostol was used 4 hourly. If first cycle was unsuccessful, after break of 12 hour, second course of misoprostol was started. The primary outcome was a measure of induction to delivery time and vaginal delivery within 24 hours. Secondary outcome was to measure need of oxytocin and complications. Results: Maternal age, parity and period of gestation were comparable between groups. Number of misoprostol dose needed in group A was significantly less than group B. Mann Whitney U test showed, women in group A had significantly earlier onset of labor, however total induction to delivery interval was not significant. In group-A, 85.7% delivered within 24 hours of first dose of misoprostol while in group-B 70% delivered within 24 hour (p=0.07). More women in Group B required oxytocin. Conclusion: Pretreatment with mifepristone before IOL following late IUFD is an effective and safe regimen. It appears to shorten the duration of induction to onset of labor.

Keywords: induction of labor, intrauterine fetal death, mifepristone, misoprostol

Procedia PDF Downloads 354
14834 Study of the Protective Effects of Summer Savory against Multiple Organ Damage Induced by Lead Acetate in Rats

Authors: Bassant M. M. Ibrahim, Doha H. Abou Baker, Ahmed Abd Elghafour

Abstract:

Excessive exposure to heavy metals contributes to the occurrence of deleterious health problems that affect vital organs like the brain, liver, kidneys, and heart. The use of natural products that have antioxidant capabilities may contribute to the protection of these organs. In the present study, the essential oil of summer savory (Satureja hortensis) was used to evaluate its protective effects against lead acetate induced damaging effect on rats’ vital organs, due to its high contents of carvacrol, y-terpinene, and p-cymene. Forty female Wister Albino rats were classified into five equal groups, the 1st served as normal group, the 2nd served as positive control group was given lead acetate (60 mg/kg) intra-peritoneal (IP), the third to fifth groups were treated with calcium disodium (EDTA) as chelating agent and summer savory essential oil in doses of (50 and 100mg/kg) respectively. All treatments were given IP concomitant with lead acetate for ten successive days. At the end of the experiment duration electrocardiogram (ECG), an open field test for the evaluation of psychological state, rotarod test as for the evaluation of locomotor coordination ability as well as anti-inflammatory and oxidative stress biomarkers in serum and histopathology of vital organs were performed. The investigations in this study show that the protective effect of high dose of summer savory essential oil is more than the low dose and that the essential oil of summer savory is a promising agent that can contribute to the protection of vital organs against the hazardous damaging effects of lead acetate.

Keywords: brain, heart, kidneys, lead acetate, liver, protective, summer savory

Procedia PDF Downloads 105
14833 Cylindrical Spacer Shape Optimization for Enhanced Inhalation Therapy

Authors: Shahab Azimi, Siamak Arzanpour, Anahita Sayyar

Abstract:

Asthma and Chronic obstructive pulmonary disease (COPD) are common lung diseases that have a significant global impact. Pressurized metered dose inhalers (pMDIs) are widely used for treatment, but they can have limitations such as high medication release speed resulting in drug deposition in the mouth or oral cavity and difficulty achieving proper synchronization with inhalation by users. Spacers are add-on devices that improve the efficiency of pMDIs by reducing the release speed and providing space for aerosol particle breakup to have finer and medically effective medication. The aim of this study is to optimize the size and cylindrical shape of spacers to enhance their drug delivery performance. The study was based on fluid dynamics theory and employed Ansys software for simulation and optimization. Results showed that optimization of the spacer's geometry greatly influenced its performance and improved drug delivery. This study provides a foundation for future research on enhancing the efficiency of inhalation therapy for lung diseases.

Keywords: asthma, COPD, pressurized metered dose inhalers, spacers, CFD, shape optimization

Procedia PDF Downloads 62
14832 Comparison Between Two Techniques (Extended Source to Surface Distance & Field Alignment) Of Craniospinal Irradiation (CSI) In the Eclipse Treatment Planning System

Authors: Naima Jannat, Ariful Islam, Sharafat Hossain

Abstract:

Due to the involvement of the large target volume, Craniospinal Irradiation makes it challenging to achieve a uniform dose, and it requires different isocenters. This isocentric junction needs to shift after every five fractions to overcome the possibility of hot and cold spots. This study aims to evaluate the Planning Target Volume coverage & sparing Organ at Risk between two techniques and shows that the Field Alignment Technique does not need replanning and resetting. Planning method for Craniospinal Irradiation by Eclipse treatment planning system Field Alignment and Extended Source to Surface Distance technique was developed where 36 Gy in 20 Fraction at the rate of 1.8 Gy was prescribed. The patient was immobilized in the prone position. In the Field Alignment technique, the plan consists of half beam blocked parallel opposed cranium and a single posterior cervicospine field was developed by sharing the same isocenter, which obviates divergence matching. Further, a single field was created to treat the remaining lumbosacral spine. Matching between the inferior diverging edge of the cervicospine field and the superior diverging edge of a lumbosacral field, the field alignment option was used, which automatically matches the field edge divergence as per the field alignment rule in Eclipse Treatment Planning System where the couch was set to 2700. In the Extended Source to Surface Distance technique, two parallel opposed fields were created for the cranium, and a single posterior cervicospine field was created where the Source to Surface Distance was from 120-140 cm. Dose Volume Histograms were obtained for each organ contoured and for each technique used. In all, the patient’s maximum dose to Planning Target Volume is higher for the Extended Source to Surface Distance technique to Field Alignment technique. The dose to all surrounding structures was increased with the use of a single Extended Source to Surface Distance when compared to the Field Alignment technique. The average mean dose to Eye, Brain Steam, Kidney, Oesophagus, Heart, Liver, Lung, and Ovaries were respectively (58% & 60 %), (103% & 98%), (13% & 15%), (10% & 63%), (12% & 16%), (33% & 30%), (14% & 18%), (69% & 61%) for Field Alignment and Extended Source to Surface Distance technique. However, the clinical target volume at the spine junction site received a less homogeneous dose with the Field Alignment technique as compared to Extended Source to Surface Distance. We conclude that, although the use of a single field Extended Source to Surface Distance delivered a more homogenous, but its maximum dose is higher than the Field Alignment technique. Also, a huge advantage of the Field Alignment technique for Craniospinal Irradiation is that it doesn’t need replanning and resetting up of patients after every five fractions and 95% prescribed dose was received by more than 95% of the Planning Target Volume in all the plane with the acceptable hot spot.

Keywords: craniospinalirradiation, cranium, cervicospine, immobilize, lumbosacral spine

Procedia PDF Downloads 82
14831 Predictors for Success in Methadone Maintenance Treatment Clinic: 24 Years of Experience

Authors: Einat E. Peles, Shaul Schreiber, Miriam Adelson

Abstract:

Background: Since established more than 50 years ago, methadone maintenance treatment (MMT) is the most effective treatment for opioid addiction, a chronic relapsing brain disorder that became an epidemic in western societies. Treatment includes daily individual optimal medication methadone dose (a long acting mu opioid receptor full agonist), accompanied with psychosocial therapy. It is well established that the longer retention in treatment the better outcome and survival occur. It reduces the likelihood to infectious diseases and overdose death that associated with drug injecting, enhanced social rehabilitation and eliminate criminal activity, and lead to healthy productive life. Aim: To evaluate predictors for long term retention in treatment we analyzed our prospective follow up of a major MMT clinic affiliated to a big tertiary medical center. Population Methods: Between June 25, 1993, and June 24, 2016, all 889 patients ( ≥ 18y) who ever admitted to the clinic were prospectively followed-up until May 2017. Duration in treatment from the first admission until the patient quit treatment or until the end of follow-up (24 years) was taken for calculating cumulative retention in treatment using survival analyses (Kaplan Meier) with log-rank and Cox regression for multivariate analyses. Results: Of the 889 patients, 25.2% were females who admitted to treatment at younger age (35.0 ± 7.9 vs. 40.6 ± 9.8, p < .0005), but started opioid usage at same age (22.3 ± 6.9). In addition to opioid use, on admission to MMT 58.5% had positive urine for benzodiazepines, 25% to cocaine, 12.4% to cannabis and 6.9% to amphetamines. Hepatitis C antibody tested positive in 55%, and HIV in 7.8% of the patients and 40%. Of all patients, 75.7% stayed at least one year in treatment, and of them, 67.7% stopped opioid usage (based on urine tests), and a net reduction observed in all other substance abuse (proportion of those who stopped minus proportion of those who have started). Long term retention up to 24 years was 8.0 years (95% Confidence Interval (CI) 7.4-8.6). Predictors for longer retention in treatment (Cox regression) were being older on admission ( ≥ 30y) Odds Ratio (OR) =1.4 (CI 1.1-1.8), not abusing opioids after one year OR=1.8 (CI 1.5-2.1), not abusing benzodiazepine after one year OR=1.7 (CI 1.4-2.1) and treating with methadone dose ≥ 100mg/day OR =1.8 (CI 1.5-2.3). Conclusions: Treating and following patients over 24 years indicate success of two main outcomes, high rate of retention after one year (75.7%) and high proportion of opiate abuse cessation (67.7%). As expected, longer cumulative retention was associated with patients treated with high adequate methadone dose that successfully result in opioid cessation. Based on these findings, in order to reduce morbidity and mortality, we find the establishment of more MMT clinics within a general hospital, a most urgent necessity.

Keywords: methadone maintenance treatment, epidemic, opioids, retention

Procedia PDF Downloads 174
14830 Radioactivity Assessment of Sediments in Negombo Lagoon Sri Lanka

Authors: H. M. N. L. Handagiripathira

Abstract:

The distributions of naturally occurring and anthropogenic radioactive materials were determined in surface sediments taken at 27 different locations along the bank of Negombo Lagoon in Sri Lanka. Hydrographic parameters of lagoon water and the grain size analyses of the sediment samples were also carried out for this study. The conductivity of the adjacent water was varied from 13.6 mS/cm to 55.4 mS/cm near to the southern end and the northern end of the lagoon, respectively, and equally salinity levels varied from 7.2 psu to 32.1 psu. The average pH in the water was 7.6 and average water temperature was 28.7 °C. The grain size analysis emphasized the mass fractions of the samples as sand (60.9%), fine sand (30.6%) and fine silt+clay (1.3%) in the sampling locations. The surface sediment samples of wet weight, 1 kg each from upper 5-10 cm layer, were oven dried at 105 °C for 24 hours to get a constant weight, homogenized and sieved through a 2 mm sieve (IAEA technical series no. 295). The radioactivity concentrations were determined using gamma spectrometry technique. Ultra Low Background Broad Energy High Purity Ge Detector, BEGe (Model BE5030, Canberra) was used for radioactivity measurement with Canberra Industries' Laboratory Source-less Calibration Software (LabSOCS) mathematical efficiency calibration approach and Geometry composer software. The mean activity concentration was found to be 24 ± 4, 67 ± 9, 181 ± 10, 59 ± 8, 3.5 ± 0.4 and 0.47 ± 0.08 Bq/kg for 238U, 232Th, 40K, 210Pb, 235U and 137Cs respectively. The mean absorbed dose rate in air, radium equivalent activity, external hazard index, annual gonadal dose equivalent and annual effective dose equivalent were 60.8 nGy/h, 137.3 Bq/kg, 0.4, 425.3 mSv/year and 74.6 mSv/year, respectively. The results of this study will provide baseline information on the natural and artificial radioactive isotopes and environmental pollution associated with information on radiological risk.

Keywords: gamma spectrometry, lagoon, radioactivity, sediments

Procedia PDF Downloads 118
14829 Impact of ‎Foliar ‎Formulations of Macro and Micro Nutrients on ‎the ‎Tritrophic Association of Wheat Aphid ‎and Entomophagous Insects

Authors: Muhammad Sufyan, Muhammad J. Arif, Muhammad Arshad, Usman Shoukat

Abstract:

In Pakistan, wheat (Triticum aestivum L.) is seriously attacked by the wheat ‎aphid. Naturally, bio control agents play an important role in managing wheat aphid. However, association ‎among pest, natural enemies and host plant is highly affected by food resource ‎concentration and predator/parasitoid factor of any ecosystem. The present ‎study was conducted to estimate the effect of different dose levels of macro ‎and micronutrients on the aphid population and its entomophagous insect ‎on wheat and their tri-trophic association. The experiment was laid out in ‎RCBD with six different combinations of macro and micronutrients and a control treatment. The data was initiated from the second week of ‎the February till the maturity of the crop. Data regarding aphid population and ‎coccinellids counts were collected on weekly basis and subjected to analysis of ‎variance and mean comparison. The data revealed that aphid ‎population was at peak in the last week of March. Coccinellids population ‎increased side by side with aphid population and declined after second week of ‎April. Aphid parasitism was maximum 25% on recommended dose of Double and ‎Flasher and minimum 8.67% on control treatment. Maximum aphid population was observed on first April with 687.2 specimens. However, this maximum population was shown against the application of Double + Flasher treatment. The minimum aphid population was recorded after the application of HiK Gold + Flasher recommended dose on 15th April. The coccinellids population was at peak level at on 8th April and against the treatment double recommended dose of HiK gold + Flasher. Amount of nitrogen, phosphorus and potassium percentage dry leaves ‎components was maximum (2.33, 0.18 and 2.62 % dry leaves. respectively) in ‎plots treated with recommended double dose mixture of Double + Flasher and ‎Hi-K Gold + Flasher while it was minimum (1.43, 0.12 and 1.77 dry leaves ‎respectively) in plots where no nutrients applied. The result revealed that maximum parasitism was at recommended level of micro and macro nutrients application.‎ Maximum micro nutrients zinc, copper, manganese, iron and boron found with values 46.67 ppm, 21.81 ppm, 62.35 ppm, 152.69 ppm and 36.78 respectively. The result also showed that Over application of macro and micro nutrients should be avoided because it do not help in pest control, conversely it may cause stress on plant. The treatment Double and Flasher recommended dose ratio is almost comparable with recommended dose and present studies confirm its usefulness on wheat.

Keywords: entomophagous insects, macro and micro nutrients, tri-trophic, wheat aphid

Procedia PDF Downloads 207
14828 The Impact of CYP2C9 Gene Polymorphisms on Warfarin Dosing

Authors: Weaam Aldeeban, Majd Aljamali, Lama A. Youssef

Abstract:

Background & Objective: Warfarin is considered a problematic drug due to its narrow therapeutic window and wide inter-individual response variations, which are attributed to demographic, environmental, and genetic factors, particularly single nucleotide polymorphism (SNPs) in the genes encoding VKORC1 and CYP2C9 involved in warfarin's mechanism of action and metabolism, respectively. CYP2C9*2rs1799853 and CYP2C9*3rs1057910 alleles are linked to reduced enzyme activity, as carriers of either or both alleles are classified as moderate or slow metabolizers, and therefore exhibit higher sensitivity of warfarin compared with wild type (CYP2C9*1*1). Our study aimed to assess the frequency of *1, *2, and *3 alleles in the CYP2C9 gene in a cohort of Syrian patients receiving a maintenance dose of warfarin for different indications, the impact of genotypes on warfarin dosing, and the frequency of adverse effects (i.e., bleedings). Subjects & Methods: This retrospective cohort study encompassed 94 patients treated with warfarin. Patients’ genotypes were identified by sequencing the polymerase chain reaction (PCR) specific products of the gene encoding CYP2C9, and the effects on warfarin therapeutic outcomes were investigated. Results: Sequencing revealed that 43.6% of the study population has the *2 and/or *3 SNPs. The mean weekly maintenance dose of warfarin was 37.42 ± 15.5 mg for patients with the wild-type allele (CYP2C9*1*1), whereas patients with one or both variants (*2 and/or *3) demanded a significantly lower dose (28.59 ±11.58 mg) of warfarin, (P= 0.015). A higher percentage (40.7%) of patients with allele *2 and/or *3 experienced hemorrhagic accidents compared with only 17.9% of patients with the wild type *1*1, (P = 0.04). Conclusions: Our study proves an association between *2 and *3 genotypes and higher sensitivity to warfarin and a tendency to bleed, which necessitates lowering the dose. These findings emphasize the significance of CYP2C9 genotyping prior to commencing warfarin therapy in order to achieve optimal and faster dose control and to ensure effectiveness and safety.

Keywords: warfarin, CYP2C9, polymorphisms, Syrian, hemorrhage

Procedia PDF Downloads 129
14827 Evaluation of Golden Beam Data for the Commissioning of 6 and 18 MV Photons Beams in Varian Linear Accelerator

Authors: Shoukat Ali, Abdul Qadir Jandga, Amjad Hussain

Abstract:

Objective: The main purpose of this study is to compare the Percent Depth dose (PDD) and In-plane and cross-plane profiles of Varian Golden beam data to the measured data of 6 and 18 MV photons for the commissioning of Eclipse treatment planning system. Introduction: Commissioning of treatment planning system requires an extensive acquisition of beam data for the clinical use of linear accelerators. Accurate dose delivery require to enter the PDDs, Profiles and dose rate tables for open and wedges fields into treatment planning system, enabling to calculate the MUs and dose distribution. Varian offers a generic set of beam data as a reference data, however not recommend for clinical use. In this study, we compared the generic beam data with the measured beam data to evaluate the reliability of generic beam data to be used for the clinical purpose. Methods and Material: PDDs and Profiles of Open and Wedge fields for different field sizes and at different depths measured as per Varian’s algorithm commissioning guideline. The measurement performed with PTW 3D-scanning water phantom with semi-flex ion chamber and MEPHYSTO software. The online available Varian Golden Beam Data compared with the measured data to evaluate the accuracy of the golden beam data to be used for the commissioning of Eclipse treatment planning system. Results: The deviation between measured vs. golden beam data was in the range of 2% max. In PDDs, the deviation increases more in the deeper depths than the shallower depths. Similarly, profiles have the same trend of increasing deviation at large field sizes and increasing depths. Conclusion: Study shows that the percentage deviation between measured and golden beam data is within the acceptable tolerance and therefore can be used for the commissioning process; however, verification of small subset of acquired data with the golden beam data should be mandatory before clinical use.

Keywords: percent depth dose, flatness, symmetry, golden beam data

Procedia PDF Downloads 462
14826 Early Hypothyroidism after Radiotherapy for Nasopharyngeal Carcinoma

Authors: Nejla Fourati, Zied Fessi, Fatma Dhouib, Wicem Siala, Leila Farhat, Afef Khanfir, Wafa Mnejja, Jamel Daoud

Abstract:

Purpose: Radiation induced hypothyroidism in nasopharyngeal cancer (NPC) ranged from 15% to 55%. In reported data, it is considered as a common late complication of definitive radiation and is mainly observed 2 years after the end of treatment. The aim of this study was to evaluate the incidence of early hypothyroidism within 6 months after radiotherapy. Patients and methods: From June 2017 to February 2020, 35 patients treated with concurrent chemo-radiotherapy (CCR) for NPC were included in this prospective study. Median age was 49 years [23-68] with a sex ratio of 2.88. All patients received intensity modulated radiotherapy (IMRT) at a dose of 69.96 Gy in 33 daily fractions with weekly cisplatin (40mg/m²) chemotherapy. Thyroid stimulating hormone (TSH) and Free Thyroxine 4 (FT4) dosage was performed before the start of radiotherapy and 6 months after. Different dosimetric parameters for the thyroid gland were reported: the volume (cc); the mean dose (Dmean) and the %age of volume receiving more than 45 Gy (V45Gy). Wilcoxon Test was used to compare these different parameters between patients with or without hypothyroidism. Results: At baseline, 5 patients (14.3%) had hypothyroidism and were excluded from the analysis. For the remaining 30 patients, 9 patients (30%) developed a hypothyroidism 6 months after the end of radiotherapy. The median thyroid volume was 10.3 cc [4.6-23]. The median Dmean and V45Gy were 48.3 Gy [43.15-55.4] and 74.8 [38.2-97.9] respectively. No significant difference was noted for all studied parameters. Conclusion: Early hypothyroidism occurring within 6 months after CCR for NPC seems to be a common complication (30%) that should be screened. Good patient monitoring with regular dosage of TSH and FT4 makes it possible to treat hypothyroidism in asymptomatic phase. This would be correlated with an improvement in the quality of life of these patients. The results of our study do not show a correlation between the thyroid doses and the occurrence of hypothyroidism. This is probably related to the high doses received by the thyroid in our series. These findings encourage more optimization to limit thyroid doses and then the risk of radiation-induced hypothyroidism

Keywords: nasopharyngeal carcinoma, hypothyroidism, early complication, thyroid dose

Procedia PDF Downloads 112