Search results for: operating room nursing
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 4187

Search results for: operating room nursing

3317 Estimating the Receiver Operating Characteristic Curve from Clustered Data and Case-Control Studies

Authors: Yalda Zarnegarnia, Shari Messinger

Abstract:

Receiver operating characteristic (ROC) curves have been widely used in medical research to illustrate the performance of the biomarker in correctly distinguishing the diseased and non-diseased groups. Correlated biomarker data arises in study designs that include subjects that contain same genetic or environmental factors. The information about correlation might help to identify family members at increased risk of disease development, and may lead to initiating treatment to slow or stop the progression to disease. Approaches appropriate to a case-control design matched by family identification, must be able to accommodate both the correlation inherent in the design in correctly estimating the biomarker’s ability to differentiate between cases and controls, as well as to handle estimation from a matched case control design. This talk will review some developed methods for ROC curve estimation in settings with correlated data from case control design and will discuss the limitations of current methods for analyzing correlated familial paired data. An alternative approach using Conditional ROC curves will be demonstrated, to provide appropriate ROC curves for correlated paired data. The proposed approach will use the information about the correlation among biomarker values, producing conditional ROC curves that evaluate the ability of a biomarker to discriminate between diseased and non-diseased subjects in a familial paired design.

Keywords: biomarker, correlation, familial paired design, ROC curve

Procedia PDF Downloads 235
3316 A Study of Heavy Hydrocarbons Upgrading by Microwave Pyrolysis

Authors: Thanida Sritangthong, Suksun Amornraksa

Abstract:

By-product upgrading is crucial in hydrocarbon industries as it can increase overall profit margin of the business. Microwave-assisted pyrolysis is relatively new technique which induces heat directly to raw materials. This results in a more energy saving and more energy-efficient process. It is also a promising method to enhance and accelerate chemical reactions, thus reducing the pyrolysis reaction time and increasing the quality of value-added products from different kinds of feedstocks. In this study, upgrading opportunity of fuel oil by-product from an olefins plant is investigated by means of microwave pyrolysis. The experiment was conducted in a lab-scale quartz reactor placed inside a 1,100 watts household microwave oven. Operating temperature was varied from 500 to 900C to observe the consequence on the quality of pyrolysis products. Several microwave receptors i.e. activated carbon, silicon carbide (SiC) and copper oxide (CuO) were used as a material to enhance the heating and reaction in the reactor. The effect of residence time was determined by adjusting flow rate of N2 carrier gas. The chemical composition and product yield were analyzed by using gas chromatography (GC) and gas chromatography/mass spectrometry (GC/MS). The results showed that hydrogen, methane, ethylene, and ethane were obtained as the main gaseous products from all operating temperatures while the main liquid products were alkane, cycloalkane and polycyclic aromatic groups. The results indicated that microwave pyrolysis has a potential to upgrade low value hydrocarbons to high value products.

Keywords: fuel oil, heavy hydrocarbons, microwave pyrolysis, pyrolysis

Procedia PDF Downloads 314
3315 Energy Storage Modelling for Power System Reliability and Environmental Compliance

Authors: Rajesh Karki, Safal Bhattarai, Saket Adhikari

Abstract:

Reliable and economic operation of power systems are becoming extremely challenging with large scale integration of renewable energy sources due to the intermittency and uncertainty associated with renewable power generation. It is, therefore, important to make a quantitative risk assessment and explore the potential resources to mitigate such risks. Probabilistic models for different energy storage systems (ESS), such as the flywheel energy storage system (FESS) and the compressed air energy storage (CAES) incorporating specific charge/discharge performance and failure characteristics suitable for probabilistic risk assessment in power system operation and planning are presented in this paper. The proposed methodology used in FESS modelling offers flexibility to accommodate different configurations of plant topology. It is perceived that CAES has a high potential for grid-scale application, and a hybrid approach is proposed, which embeds a Monte-Carlo simulation (MCS) method in an analytical technique to develop a suitable reliability model of the CAES. The proposed ESS models are applied to a test system to investigate the economic and reliability benefits of the energy storage technologies in system operation and planning, as well as to assess their contributions in facilitating wind integration during different operating scenarios. A comparative study considering various storage system topologies are also presented. The impacts of failure rates of the critical components of ESS on the expected state of charge (SOC) and the performance of the different types of ESS during operation are illustrated with selected studies on the test system. The paper also applies the proposed models on the test system to investigate the economic and reliability benefits of the different ESS technologies and to evaluate their contributions in facilitating wind integration during different operating scenarios and system configurations. The conclusions drawn from the study results provide valuable information to help policymakers, system planners, and operators in arriving at effective and efficient policies, investment decisions, and operating strategies for planning and operation of power systems with large penetrations of renewable energy sources.

Keywords: flywheel energy storage, compressed air energy storage, power system reliability, renewable energy, system planning, system operation

Procedia PDF Downloads 127
3314 Integrating Nursing Informatics to Improve Patient-Centered Care: A Project to Reduce Patient Waiting Time at the Blood Pressure Counter

Authors: Pi-Chi Wu, Tsui-Ping Chu, Hsiu-Hung Wang

Abstract:

Background: The ability to provide immediate medical service in outpatient departments is one of the keys to patient satisfaction. Objectives: This project used electronic equipment to integrate nursing care information to patient care at a blood pressure diagnostic counter. Through process reengineering, the average patient waiting time decreased from 35 minutes to 5 minutes, while service satisfaction increased from a score of 2.7 to 4.6. Methods: Data was collected from a local hospital in Southern Taiwan from a daily average of 2,200 patients in the outpatient department. Previous waiting times were affected by (1) space limitations, (2) the need to help guide patient mobility, (3) the need for nurses to appease irate patients and give instructions, (4), the need for patients to replace lost counter tickets, (5) the need to re-enter information, (6) the replacement of missing patient information. An ad hoc group was established to enhance patient satisfaction and shorten waiting times for patients to see a doctor. A four step strategy consisting of (1) counter relocation, (2) queue reorganization, (3) electronic information integration, (4) process reengineering was implemented. Results: Implementation of the developed strategy decreased patient waiting time from 35 minutes to an average of 5 minutes, and increased patient satisfaction scores from 2.7 to 6.4. Conclusion: Through the integration of information technology and process transformation, waiting times were drastically reduced, patient satisfaction increased, and nurses were allowed more time to engage in more cost-effective services. This strategy was simultaneously enacted in separate hospitals throughout Taiwan.

Keywords: process reengineering, electronic information integration, patient satisfaction, patient waiting time

Procedia PDF Downloads 373
3313 An Investigation about the Health-Promoting Lifestyle of 1389 Emergency Nurses in China

Authors: Lei Ye, Min Liu, Yong-Li Gao, Jun Zhang

Abstract:

Purpose: The aims of the study are to investigate the status of health-promoting lifestyle and to compare the healthy lifestyle of emergency nurses in different levels of hospitals in Sichuan province, China. The investigation is mainly about the health-promoting lifestyle, including spiritual growth, health responsibility, physical activity, nutrition, interpersonal relations, stress management. Then the factors were analyzed influencing the health-promoting lifestyle of emergency nurses in hospitals of Sichuan province in order to find the relevant models to provide reference evidence for intervention. Study Design: A cross-sectional research method was adopted. Stratified cluster sampling, based on geographical location, was used to select the health facilities of 1389 emergency nurses in 54 hospitals from Sichuan province in China. Method: The 52-item, six-factor structure Health-Promoting Lifestyle Profile II (HPLP- II) instrument was used to explore participants’ self-reported health-promoting behaviors and measure the dimensions of health responsibility, physical activity, nutrition, interpersonal relations, spiritual growth, and stress management. Demographic characteristics, education, work duration, emergency nursing work duration and self-rated health status were documented. Analysis: Data were analyzed through SPSS software ver. 17.0. Frequency, percentage, mean ± standard deviation were used to describe the general information, while the Nonparametric Test was used to compare the constituent ratio of general data of different hospitals. One-way ANOVA was used to compare the scores of health-promoting lifestyle in different levels hospital. A multiple linear regression model was established. P values which were less than 0.05 determined statistical significance in all analyses. Result: The survey showed that the total score of health-promoting lifestyle of nurses at emergency departments in Sichuan Province was 120.49 ± 21.280. The relevant dimensions are ranked by scores in descending order: interpersonal relations, nutrition, health responsibility, physical activity, stress management, spiritual growth. The total scores of the three-A hospital were the highest (121.63 ± 0.724), followed by the senior class hospital (119.7 ± 1.362) and three-B hospital (117.80 ± 1.255). The difference was statistically significant (P=0.024). The general data of nurses was used as the independent variable which includes age, gender, marital status, living conditions, nursing income, hospital level, Length of Service in nursing, Length of Service in emergency, Professional Title, education background, and the average number of night shifts. The total score of health-promoting lifestyle was used as dependent variable; Multiple linear regression analysis method was adopted to establish the regression model. The regression equation F = 20.728, R2 = 0.061, P < 0.05, the age, gender, nursing income, turnover intention and status of coping stress affect the health-promoting lifestyle of nurses in emergency department, the result was statistically significant (P < 0.05 ). Conclusion: The results of the investigation indicate that it will help to develop health promoting interventions for emergency nurses in all levels of hospital in Sichuan Province through further research. Managers need to pay more attention to emergency nurses’ exercise, stress management, self-realization, and conduct intervention in nurse training programs.

Keywords: emergency nurse, health-promoting lifestyle profile II, health behaviors, lifestyle

Procedia PDF Downloads 278
3312 An Experimental Study to Investigate the Behaviour of Torque Fluctuation of Crossflow Turbines Operating in an Open Channel

Authors: Sunil Kumar Singal, Manoj Sood, Upendra Bajpai

Abstract:

Instream technology is the upcoming sustainable approach in the hydro sector for energy harnessing. With well-known cross-sections and regulated supply, open channels are the most prominent locations for the installation of hydrokinetic turbines. The fluctuation in generated torque varies with site condition (flow depth and flow velocity), as well as with the type of turbine. The present experimental study aims to investigate the torque/power fluctuations of crossflow hydrokinetic turbines operating at different flow velocities and water depths. The flow velocity is varied from 1.0 m/s to 2.0 m/s. The complete assembly includes an open channel having dimensions of 0.3 m (depth) x 0.71 m (width) x 4.5 m (length), along with a lifting mechanism for varying the channel slope, a digital transducer for monitoring the torque, power, and rpm, a digital handheld water velocity meter for measuring the flow velocity. Further, a time series of torque, power, and rpm is plotted for a duration of 30 minutes showing the continuous operation of the turbine. A comparison of Savonius, Darrieus, and their improved twisted and helical blades is also presented in the study. A correlation has also been developed for assessing the hydropower generation from the installed turbine. The developed correlations will be very useful in the decision-making process for development at a site.

Keywords: darrieus turbine, flow velocity, open channel, savoinus turbine, water depth, hydropower

Procedia PDF Downloads 78
3311 Comparative Syudy Of Heat Transfer Capacity Limits of Heat Pipe

Authors: H. Shokouhmand, A. Ghanami

Abstract:

Heat pipe is simple heat transfer device which combines the conduction and phase change phenomena to control the heat transfer without any need for external power source. At hot surface of heat pipe, the liquid phase absorbs heat and changes to vapor phase. The vapor phase flows to condenser region and with the loss of heat changes to liquid phase. Due to gravitational force the liquid phase flows to evaporator section.In HVAC systems the working fluid is chosen based on the operating temperature. The heat pipe has significant capability to reduce the humidity in HVAC systems. Each HVAC system which uses heater, humidifier or dryer is a suitable nominate for the utilization of heat pipes. Generally heat pipes have three main sections: condenser, adiabatic region and evaporator.Performance investigation and optimization of heat pipes operation in order to increase their efficiency is crucial. In present article, a parametric study is performed to improve the heat pipe performance. Therefore, the heat capacity of heat pipe with respect to geometrical and confining parameters is investigated. For the better observation of heat pipe operation in HVAC systems, a CFD simulation in Eulerian- Eulerian multiphase approach is also performed. The results show that heat pipe heat transfer capacity is higher for water as working fluid with the operating temperature of 340 K. It is also observed that the vertical orientation of heat pipe enhances it’s heat transfer capacity.

Keywords: heat pipe, HVAC system, grooved heat pipe, heat pipe limits

Procedia PDF Downloads 367
3310 Heat Pipe Thermal Performance Improvement in H-VAC Systems Using CFD Modeling

Authors: H. Shokouhmand, A. Ghanami

Abstract:

Heat pipe is a simple heat transfer device which combines the conduction and phase change phenomena to control the heat transfer without any need for external power source. At hot surface of the heat pipe, the liquid phase absorbs heat and changes to vapor phase. The vapor phase flows to condenser region and with the loss of heat changes to liquid phase. Due to gravitational force, the liquid phase flows to evaporator section. In HVAC systems, the working fluid is chosen based on the operating temperature. The heat pipe has significant capability to reduce the humidity in HVAC systems. Each HVAC system which uses heater, humidifier or dryer is a suitable nominate for the utilization of heat pipes. Generally, heat pipes have three main sections: condenser, adiabatic region, and evaporator.Performance investigation and optimization of heat pipes operation in order to increase their efficiency is crucial. In the present article, a parametric study is performed to improve the heat pipe performance. Therefore, the heat capacity of the heat pipe with respect to geometrical and confining parameters is investigated. For the better observation of heat pipe operation in HVAC systems, a CFD simulation in Eulerian- Eulerian multiphase approach is also performed. The results show that heat pipe heat transfer capacity is higher for water as working fluid with the operating temperature of 340 K. It is also showed that the vertical orientation of heat pipe enhances its heat transfer capacity.

Keywords: heat pipe, HVAC system, grooved heat pipe, CFD simulation

Procedia PDF Downloads 492
3309 Heat Pipes Thermal Performance Improvement in H-VAC Systems Using CFD Modeling

Authors: M. Heydari, A. Ghanami

Abstract:

Heat pipe is simple heat transfer device which combines the conduction and phase change phenomena to control the heat transfer without any need for external power source. At hot surface of heat pipe, the liquid phase absorbs heat and changes to vapor phase. The vapor phase flows to condenser region and with the loss of heat changes to liquid phase. Due to gravitational force the liquid phase flows to evaporator section.In HVAC systems the working fluid is chosen based on the operating temperature. The heat pipe has significant capability to reduce the humidity in HVAC systems. Each HVAC system which uses heater, humidifier or dryer is a suitable nominate for the utilization of heat pipes. Generally heat pipes have three main sections: condenser, adiabatic region and evaporator.Performance investigation and optimization of heat pipes operation in order to increase their efficiency is crucial. In present article, a parametric study is performed to improve the heat pipe performance. Therefore, the heat capacity of heat pipe with respect to geometrical and confining parameters is investigated. For the better observation of heat pipe operation in HVAC systems, a CFD simulation in Eulerian- Eulerian multiphase approach is also performed. The results show that heat pipe heat transfer capacity is higher for water as working fluid with the operating temperature of 340 K. It is also showed that the vertical orientation of heat pipe enhances it’s heat transfer capacity.

Keywords: heat pipe, HVAC system, grooved heat pipe, heat pipe limits

Procedia PDF Downloads 441
3308 Healthcare Professional’s Well-Being: Case Study of Two Care Units in a Big Hospital in Canada

Authors: Zakia Hammouni

Abstract:

Healthcare professionals’ well-being is becoming a priority during this Covid-19 pandemic due to stress, fatigue, and workload. Well before this pandemic, contemporary hospitals are endowed with environmental attributes that contribute to achieving well-being within their environment with the emphasis on the patient. The patient-centered care approach has been followed by the patient-centered design approach. Studies that have focused on the physical environment in hospitals have dealt with the patient's recovery process and his well-being. Prior scientific literature has placed less emphasis on the healthcare professionals’ interactions within the physical environment and to guide hospital designers to make evidence-based design choices to meet the needs and expectations of hospital users by considering, in addition to patients, healthcare professionals. This paper examines these issues related to the daily stress of professionals who provide care in a hospital environment. In this exploratory study, the interest was to grasp the issues related to this environment and explores the current realities of newly built hospitals based on design approaches and what attributes of the physical setting support healthcare professional’s well-being. Within a constructivist approach, this study was conducted in two care units in a new hospital in a big city in Canada before the Covid-19 pandemic (august 2nd to November 2nd 2018). A spatial evaluation of these care units allowed us to understand the interaction of health professionals in their work environment, to understand the spatial behavior of these professionals, and the narratives from 44 interviews of various healthcare professionals. The mental images validated the salient components of the hospital environment as perceived by these healthcare professionals. Thematic analysis and triangulation of the data set were conducted. Among the key attributes promoting the healthcare professionals’ well-being as revealed by the healthcare professionals are the overall light-color atmosphere in the hospital and care unit, particularly in the corridors and public areas of the hospital, the maintenance and cleanliness. The presence of the art elements also brings well-being to the health professionals as well as panoramic views from the staff lounge and corridors of the care units or elevator lobbies. Despite the overall positive assessment of this environment, some attributes need to be improved to ensure the well-being of healthcare professionals and to provide them with a restructuring environment. These are the supply of natural light, softer colors, sufficient furniture, comfortable seating in the restroom, and views, which are important in allowing these healthcare professionals to recover from their work stress. Noise is another attribute that needs to be further improved in the hospital work environment, especially in the nursing workstations and consultant's room. In conclusion, this study highlights the importance of providing healthcare professionals with work and rest areas that allow them to resist the stress they face, particularly during periods of extreme stress and fatigue such as a Covid-19 pandemic.

Keywords: healthcare facilities, healthcare professionals, physical environment, well-being

Procedia PDF Downloads 125
3307 Psychometric Validation of Czech Version of Spiritual Needs Assessment for Patients: The First Part of Research

Authors: Lucie Mrackova, Helena Kisvetrova

Abstract:

Spirituality is an integral part of human life. In a secular environment, spiritual needs are often overlooked, especially in acute nursing care. Spiritual needs assessment for patients (SNAP), which also exists in the Czech version (SNAP-CZ), can be used for objective evaluation. The aim of this study was to measure the psychometric properties of SNAP-CZ and to find correlations between SNAP-CZ and sociodemographic and clinical variables. A cross-sectional study with tools assessing spiritual needs (SNAP-CZ), anxiety (Beck Anxiety Inventory; BAI), depression (Beck Depression Inventory; BDI), pain (Visual Analogue Scale; VAS), self-sufficiency (Barthel Index; BI); cognitive function (Montreal Cognitive Test; MoCa) and selected socio-demographic data was performed. The psychometric properties of SNAP-CZ were tested using factor analysis, reliability and validity tests, and correlations between the questionnaire and sociodemographic data and clinical variables. Internal consistency was established with Cronbach’s alfa for the overall score, respective domains, and individual items. Reliability was assessed by test-retest by Interclass correlation coefficient (ICC). Data for correlation analysis were processed according to Pearson's correlation coefficient. The study included 172 trauma patients (the mean age = 40.6 ± 12.1 years) who experienced polytrauma or severe monotrauma. There were a total of 106 (61.6%) male subjects, 140 (81.4%) respondents identified themselves as non-believers. The full-scale Cronbach's alpha was 0.907. The test-retest showed the reliability of the individual domains in the range of 0.924 to 0.960 ICC. Factor analysis resulted in a three-factor solution (psychosocial needs (alfa = 0.788), spiritual needs (alfa = 0.886) and religious needs (alfa = 0.841)). Correlation analysis using Pearson's correlation coefficient showed that the domain of psychosocial needs significantly correlated only with gender (r = 0.178, p = 0.020). Males had a statistically significant lower average value in this domain (mean = 12.5) compared to females (mean = 13.8). The domain of spiritual needs significantly correlated with gender (r = 0.199, p = 0.009), social status (r = 0.156, p = 0.043), faith (r = -0.250, p = 0.001), anxiety (r = 0.194, p = 0.011) and depression (r = 0.155, p = 0.044). The domain of religious needs significantly correlated with age (r = 0,208, p = 0,007), education (r = -0,161, p = 0,035), faith (r = -0,575, p < 0,0001) and depression (r = 0,179, p = 0,019). Overall, the whole SNAP scale significantly correlated with gender (r = 0.219, p = 0.004), social status (r = 0.175, p = 0.023), faith (r = -0.334, p <0.0001), anxiety (r = 0.177, p = 0.022) and depression (r = 0.173, p = 0.025). The results of this study corroborate the reliability of the SNAP-CZ and support its future use in the nursing care of trauma patients in a secular society. Acknowledgment: The study was supported by grant nr. IGA_FZV_2020_003.

Keywords: acute nursing care, assessment of spiritual needs, patient, psychometric validation, spirituality

Procedia PDF Downloads 100
3306 Improve Heat Pipe Thermal Performance in H-VAC Systems Using CFD Modeling

Authors: H. Shokouhmand, A. Ghanami

Abstract:

A heat pipe is simple heat transfer device which combines the conduction and phase change phenomena to control the heat transfer without any need for external power source. At a hot surface of the heat pipe, the liquid phase absorbs heat and changes to the vapor phase. The vapor phase flows to condenser region and with the loss of heat changes to the liquid phase. Due to gravitational force the liquid phase flows to the evaporator section. In HVAC systems, the working fluid is chosen based on the operating temperature. The heat pipe has significant capability to reduce the humidity in HVAC systems. Each HVAC system which uses the heater, humidifier, or dryer is a suitable nominate for the utilization of heat pipes. Generally, heat pipes have three main sections: condenser, adiabatic region, and evaporator. Performance investigation and optimization of heat pipes operation in order to increase their efficiency is crucial. In the present article, a parametric study is performed to improve the heat pipe performance. Therefore, the heat capacity of the heat pipe with respect to geometrical and confining parameters is investigated. For the better observation of heat pipe operation in HVAC systems, a CFD simulation in Eulerian-Eulerian multiphase approach is also performed. The results show that heat pipe heat transfer capacity is higher for water as working fluid with the operating temperature of 340 K. It is also showed that the vertical orientation of heat pipe enhances its heat transfer capacity.

Keywords: heat pipe, HVAC system, grooved heat pipe, heat pipe limits

Procedia PDF Downloads 432
3305 Improving Self-Administered Medication Adherence for Older Adults: A Systematic Review

Authors: Mathumalar Loganathan, Lina Syazana, Bryony Dean Franklin

Abstract:

Background: The therapeutic benefit of self-administered medication for long-term use is limited by an average 50% non-adherence rate. Patient forgetfulness is a common factor in unintentional non-adherence. With a growing ageing population, strategies to improve self-administration of medication adherence are essential. Our aim was to review systematically the effects of interventions to optimise self-administration of medication. Method: Database searched were MEDLINE, EMBASE, PsynINFO, CINAHL from 1980 to 31 October 2013. Search terms included were ‘self-administration’, ‘self-care’, ‘medication adherence’, and ‘intervention’. Two independent reviewers undertook screening and methodological quality assessment, using the Downs and Black rating scale. Results: The search strategy retrieved 6 studies that met the inclusion and exclusion criteria. Three intervention strategies were identified: self-administration medication programme (SAMP), nursing education and medication packaging (pill calendar). A nursing education programme focused on improving patients’ behavioural self-management of drug prescribing. This was the most studied area and three studies highlighting an improvement in self-administration of medication. Conclusion: Results are mixed and there is no one interventional strategy that has proved to be effective. Nevertheless, self-administration of medication programme seems to show most promise. A multi-faceted approach and clearer policy guideline are likely to be required to improve prescribing for these vulnerable patients. Mixed results were found for SAMP. Medication packaging (pill calendar) was evaluated in one study showing a significant improvement in self-administration of medication. A meta-analysis could not be performed due to heterogeneity in the outcome measures.

Keywords: self-administered medication, intervention, prescribing, older patients

Procedia PDF Downloads 320
3304 Adherence of Trauma and Orthopaedics Surgery Operative Notes to the RCS Good Surgical Practice Guidelines in Ashford and St. Peter's Hospital

Authors: Maryam Risla Shahul Hameed, Tharsiga Yogarajah, Fritzy Mathew, Tayyaba Syed, Shalin Shaunak

Abstract:

Aim: Auditing the adherence of Trauma and Orthopaedics Operative notes to the RCS Good Surgical Practice Guidelines. Method: Clinical audit conducted on 150 operative notes over a period of 2 months April- May 2023, including emergency and elective surgeries performed in Ashford and St. Peter’s Hospital. The RCS Good Practice Surgical Guidelines for an ideal operative note were used to compare.Results: Date of the procedure and signature of the surgeon were mentioned in all the notes by default in the electronic template being used. Title of the operation performed and whether elective or emergency were mentioned by 92% and 45%, respectively. Name of theatre anaesthetist and operating surgeons were mentioned by 73% and 93% respectively. Time of surgery mentioned by 26%. Operative findings and operative diagnosis mentioned by 83% and 53% respectively. Incision and complications of surgery mentioned in 80% and 53%, respectively. Details of tissue added/ altered/ removed mentioned by 46%. Information on prosthesis or implant used is mentioned by 54%. Details of closure and anticipated blood loss mentioned in 91% and 45% respectively. Antibiotic prophylaxis was mentioned by 63%, out of which only 23% mentioned the name and duration of the antibiotic. VTE prophylaxis was mentioned by 84%, out of which only 23% and 29% mentioned the name and duration of the prophylaxis, respectively. Conclusion: There is more for improvement in the operative notes for better continuity of care between the operating surgeons and other doctors in the wards taking care of the patients post operatively. We recommend to follow a standardized guidelines by all the nationwide and a standard template to be followed by all.

Keywords: surgery, notes, RCS, guidelines

Procedia PDF Downloads 159
3303 Improvement of Heat Pipe Thermal Performance in H-VAC Systems Using CFD Modeling

Authors: H. Shokouhmand, A. Ghanami

Abstract:

Heat pipe is simple heat transfer device which combines the conduction and phase change phenomena to control the heat transfer without any need for external power source. At hot surface of heat pipe, the liquid phase absorbs heat and changes to vapor phase. The vapor phase flows to condenser region and with the loss of heat changes to liquid phase. Due to gravitational force the liquid phase flows to evaporator section. In HVAC systems the working fluid is chosen based on the operating temperature. The heat pipe has significant capability to reduce the humidity in HVAC systems. Each HVAC system which uses heater, humidifier or dryer is a suitable nominate for the utilization of heat pipes. Generally heat pipes have three main sections: condenser, adiabatic region and evaporator.Performance investigation and optimization of heat pipes operation in order to increase their efficiency is crucial. In present article, a parametric study is performed to improve the heat pipe performance. Therefore, the heat capacity of heat pipe with respect to geometrical and confining parameters is investigated. For the better observation of heat pipe operation in HVAC systems, a CFD simulation in Eulerian- Eulerian multiphase approach is also performed. The results show that heat pipe heat transfer capacity is higher for water as working fluid with the operating temperature of 340 K. It is also showed that the vertical orientation of heat pipe enhances it’s heat transfer capacity used in the abstract.

Keywords: heat pipe, HVAC system, grooved heat pipe, CFD simulation

Procedia PDF Downloads 422
3302 Cost Effective Microfabrication Technique for Lab on Chip (LOC) Devices Using Epoxy Polymers

Authors: Charmi Chande, Ravindra Phadke

Abstract:

Microfluidics devices are fabricated by using multiple fabrication methods. Photolithography is one of the common methods wherein SU8 is widely used for making master which in turn is used for making working chip by the process of soft lithography. The high-aspect ratio features of SU-8 makes it suitable to be used as micro moulds for injection moulding, hot embossing, and moulds to form polydimethylsiloxane (PDMS) structures for bioMEMS (Microelectromechanical systems) applications. But due to high cost, difficulty in procuring and need for clean room, restricts the use of this polymer especially in developing countries and small research labs. ‘Bisphenol –A’ based polymers in mixture with curing agent are used in various industries like Paints and coatings, Adhesives, Electrical systems and electronics, Industrial tooling and composites. We present the novel use of ‘Bisphenol – A’ based polymer in fabricating micro channels for Lab On Chip(LOC) devices. The present paper describes the prototype for production of microfluidics chips using range of ‘Bisphenol-A’ based polymers viz. GY 250, ATUL B11, DER 331, DER 330 in mixture with cationic photo initiators. All the steps of chip production were carried out using an inexpensive approach that uses low cost chemicals and equipment. This even excludes the need of clean room. The produced chips using all above mentioned polymers were validated with respect to height and the chip giving least height was selected for further experimentation. The lowest height achieved was 7 micrometers by GY250. The cost of the master fabricated was $ 0.20 and working chip was $. 0.22. The best working chip was used for morphological identification and profiling of microorganisms from environmental samples like soil, marine water and salt water pan sites. The current chip can be adapted for various microbiological screening experiments like biochemical based microbial identification, studying uncultivable microorganisms at single cell/community level.

Keywords: bisphenol–A based epoxy, cationic photoinitiators, microfabrication, photolithography

Procedia PDF Downloads 282
3301 Improvement of Heat Pipes Thermal Performance in H-VAC Systems Using CFD Modeling

Authors: H. Shokouhmand, A. Ghanami

Abstract:

Heat pipe is simple heat transfer device which combines the conduction and phase change phenomena to control the heat transfer without any need for external power source. At hot surface of heat pipe, the liquid phase absorbs heat and changes to vapor phase. The vapor phase flows to condenser region and with the loss of heat changes to liquid phase. Due to gravitational force the liquid phase flows to evaporator section.In HVAC systems the working fluid is chosen based on the operating temperature. The heat pipe has significant capability to reduce the humidity in HVAC systems. Each HVAC system which uses heater, humidifier or dryer is a suitable nominate for the utilization of heat pipes. Generally heat pipes have three main sections: condenser, adiabatic region and evaporator.Performance investigation and optimization of heat pipes operation in order to increase their efficiency is crucial. In present article, a parametric study is performed to improve the heat pipe performance. Therefore, the heat capacity of heat pipe with respect to geometrical and confining parameters is investigated. For the better observation of heat pipe operation in HVAC systems, a CFD simulation in Eulerian- Eulerian multiphase approach is also performed. The results show that heat pipe heat transfer capacity is higher for water as working fluid with the operating temperature of 340 K. It is also showed that the vertical orientation of heat pipe enhances it’s heat transfer capacity used in the abstract.

Keywords: heat pipe, HVAC system, grooved heat pipe, heat pipe limits

Procedia PDF Downloads 361
3300 Performance Comparison of Tablet Devices and Medical Diagnostic Display Devices Using Digital Object Patterns in PACS Environment

Authors: Yan-Lin Liu, Cheng-Ting Shih, Jay Wu

Abstract:

Tablet devices have been introduced into the medical environment in recent years. The performance of display can be varied based on the use of different hardware specifications and types of display technologies. Therefore, the differences between tablet devices and medical diagnostic LCDs have to be verified to ensure that image quality is not jeopardized for clinical diagnosis in a picture archiving and communication system (PACS). In this study, a set of randomized object test patterns (ROTPs) were developed, which included randomly located spheres in abdominal CT images. Five radiologists were asked to independently review the CT images on different generations of iPads and a diagnostic monochrome medical LCD monitor. Receiver operating characteristic (ROC) analysis was performed by using a five-point rating scale, and the average area under curve (AUC) and average reading time (ART) were calculated. The AUC values for the second generation iPad, iPad mini, iPad Air, and monochrome medical monitor were 0.712, 0.717, 0.725, and 0.740, respectively. The differences between iPads were not significant. The ARTs were 177 min and 127 min for iPad mini and medical LCD monitor, respectively. A significant difference appeared (p = 0.04). The results show that the iPads were slightly inferior to the monochrome medical LCD monitor. However, tablet devices possess advantages in portability and versatility, which can improve the convenience of rapid diagnosis and teleradiology. With advances in display technology, the applicability of tablet devices and mobile devices may be more diversified in PACS.

Keywords: tablet devices, PACS, receiver operating characteristic, LCD monitor

Procedia PDF Downloads 478
3299 Comparative Study of Heat Transfer Capacity Limits of Heat Pipes

Authors: H. Shokouhmand, A. Ghanami

Abstract:

Heat pipe is simple heat transfer device which combines the conduction and phase change phenomena to control the heat transfer without any need for external power source. At hot surface of heat pipe, the liquid phase absorbs heat and changes to vapor phase. The vapor phase flows to condenser region and with the loss of heat changes to liquid phase. Due to gravitational force the liquid phase flows to evaporator section.In HVAC systems the working fluid is chosen based on the operating temperature. The heat pipe has significant capability to reduce the humidity in HVAC systems. Each HVAC system which uses heater, humidifier or dryer is a suitable nominate for the utilization of heat pipes. Generally heat pipes have three main sections: condenser, adiabatic region and evaporator.Performance investigation and optimization of heat pipes operation in order to increase their efficiency is crucial. In present article, a parametric study is performed to improve the heat pipe performance. Therefore, the heat capacity of heat pipe with respect to geometrical and confining parameters is investigated. For the better observation of heat pipe operation in HVAC systems, a CFD simulation in Eulerian- Eulerian multiphase approach is also performed. The results show that heat pipe heat transfer capacity is higher for water as working fluid with the operating temperature of 340 K. It is also showed that the vertical orientation of heat pipe enhances it’s heat transfer capacity.

Keywords: heat pipe, HVAC system, grooved Heat pipe, heat pipe limits

Procedia PDF Downloads 417
3298 Designing Ecologically and Economically Optimal Electric Vehicle Charging Stations

Authors: Y. Ghiassi-Farrokhfal

Abstract:

The number of electric vehicles (EVs) is increasing worldwide. Replacing gas fueled cars with EVs reduces carbon emission. However, the extensive energy consumption of EVs stresses the energy systems, requiring non-green sources of energy (such as gas turbines) to compensate for the new energy demand caused by EVs in the energy systems. To make EVs even a greener solution for the future energy systems, new EV charging stations are equipped with solar PV panels and batteries. This will help serve the energy demand of EVs through the green energy of solar panels. To ensure energy availability, solar panels are combined with batteries. The energy surplus at any point is stored in batteries and is used when there is not enough solar energy to serve the demand. While EV charging stations equipped with solar panels and batteries are green and ecologically optimal, they might not be financially viable solutions, due to battery prices. To make the system viable, we should size the battery economically and operate the system optimally. This is, in general, a challenging problem because of the stochastic nature of the EV arrivals at the charging station, the available solar energy, and the battery operating system. In this work, we provide a mathematical model for this problem and we compute the return on investment (ROI) of such a system, which is designed to be ecologically and financially optimal. We also quantify the minimum required investment in terms of battery and solar panels along with the operating strategy to ensure that a charging station has enough energy to serve its EV demand at any time.

Keywords: solar energy, battery storage, electric vehicle, charging stations

Procedia PDF Downloads 214
3297 Improve Heat Pipes Thermal Performance In H-VAC Systems Using CFD Modeling

Authors: A. Ghanami, M.Heydari

Abstract:

Heat pipe is simple heat transfer device which combines the conduction and phase change phenomena to control the heat transfer without any need for external power source. At hot surface of heat pipe, the liquid phase absorbs heat and changes to vapor phase. The vapor phase flows to condenser region and with the loss of heat changes to liquid phase. Due to gravitational force the liquid phase flows to evaporator section. In HVAC systems the working fluid is chosen based on the operating temperature. The heat pipe has significant capability to reduce the humidity in HVAC systems. Each HVAC system which uses heater, humidifier or dryer is a suitable nominate for the utilization of heat pipes. Generally heat pipes have three main sections: condenser, adiabatic region and evaporator. Performance investigation and optimization of heat pipes operation in order to increase their efficiency is crucial. In present article, a parametric study is performed to improve the heat pipe performance. Therefore, the heat capacity of heat pipe with respect to geometrical and confining parameters is investigated. For the better observation of heat pipe operation in HVAC systems, a CFD simulation in Eulerian- Eulerian multiphase approach is also performed. The results show that heat pipe heat transfer capacity is higher for water as working fluid with the operating temperature of 340 K. It is also showed that the vertical orientation of heat pipe enhances it’s heat transfer capacity.used in the abstract.

Keywords: Heat pipe, HVAC system, Grooved Heat pipe, Heat pipe limits.

Procedia PDF Downloads 478
3296 Experimental Verification of Similarity Criteria for Sound Absorption of Perforated Panels

Authors: Aleksandra Majchrzak, Katarzyna Baruch, Monika Sobolewska, Bartlomiej Chojnacki, Adam Pilch

Abstract:

Scaled modeling is very common in the areas of science such as aerodynamics or fluid mechanics, since defining characteristic numbers enables to determine relations between objects under test and their models. In acoustics, scaled modeling is aimed mainly at investigation of room acoustics, sound insulation and sound absorption phenomena. Despite such a range of application, there is no method developed that would enable scaling acoustical perforated panels freely, maintaining their sound absorption coefficient in a desired frequency range. However, conducted theoretical and numerical analyses have proven that it is not physically possible to obtain given sound absorption coefficient in a desired frequency range by directly scaling only all of the physical dimensions of a perforated panel, according to a defined characteristic number. This paper is a continuation of the research mentioned above and presents practical evaluation of theoretical and numerical analyses. The measurements of sound absorption coefficient of perforated panels were performed in order to verify previous analyses and as a result find the relations between full-scale perforated panels and their models which will enable to scale them properly. The measurements were conducted in a one-to-eight model of a reverberation chamber of Technical Acoustics Laboratory, AGH. Obtained results verify theses proposed after theoretical and numerical analyses. Finding the relations between full-scale and modeled perforated panels will allow to produce measurement samples equivalent to the original ones. As a consequence, it will make the process of designing acoustical perforated panels easier and will also lower the costs of prototypes production. Having this knowledge, it will be possible to emulate in a constructed model panels used, or to be used, in a full-scale room more precisely and as a result imitate or predict the acoustics of a modeled space more accurately.

Keywords: characteristic numbers, dimensional analysis, model study, scaled modeling, sound absorption coefficient

Procedia PDF Downloads 194
3295 Thermal Management of Ground Heat Exchangers Applied in High Power LED

Authors: Yuan-Ching Chiang, Chien-Yeh Hsu, Chen Chih-Hao, Sih-Li Chen

Abstract:

The p-n junction temperature of LEDs directly influences their operating life and luminous efficiency. An excessively high p-n junction temperature minimizes the output flux of LEDs, decreasing their brightness and influencing the photon wavelength; consequently, the operating life of LEDs decreases and their luminous output changes. The maximum limit of the p-n junction temperature of LEDs is approximately 120 °C. The purpose of this research was to devise an approach for dissipating heat generated in a confined space when LEDs operate at low temperatures to reduce light decay. The cooling mode of existing commercial LED lights can be divided into natural- and forced convection cooling. In natural convection cooling, the volume of LED encapsulants must be increased by adding more fins to increase the cooling area. However, this causes difficulties in achieving efficient LED lighting at high power. Compared with forced convection cooling, heat transfer through water convection is associated with a higher heat transfer coefficient per unit area; therefore, we dissipated heat by using a closed loop water cooling system. Nevertheless, cooling water exposed to air can be easily influenced by environmental factors. Thus, we incorporated a ground heat exchanger into the water cooling system to minimize the influence of air on cooling water and then observed the relationship between the amounts of heat dissipated through the ground and LED efficiency.

Keywords: helical ground heat exchanger, high power LED, ground source cooling system, heat dissipation

Procedia PDF Downloads 575
3294 Systems Approach on Thermal Analysis of an Automatic Transmission

Authors: Sinsze Koo, Benjin Luo, Matthew Henry

Abstract:

In order to increase the performance of an automatic transmission, the automatic transmission fluid is required to be warm up to an optimal operating temperature. In a conventional vehicle, cold starts result in friction loss occurring in the gear box and engine. The stop and go nature of city driving dramatically affect the warm-up of engine oil and automatic transmission fluid and delay the time frame needed to reach an optimal operating temperature. This temperature phenomenon impacts both engine and transmission performance but also increases fuel consumption and CO2 emission. The aim of this study is to develop know-how of the thermal behavior in order to identify thermal impacts and functional principles in automatic transmissions. Thermal behavior was studied using models and simulations, developed using GT-Suit, on a one-dimensional thermal and flow transport. A power train of a conventional vehicle was modeled in order to emphasis the thermal phenomena occurring in the various components and how they impact the automatic transmission performance. The simulation demonstrates the thermal model of a transmission fluid cooling system and its component parts in warm-up after a cold start. The result of these analyses will support the future designs of transmission systems and components in an attempt to obtain better fuel efficiency and transmission performance. Therefore, these thermal analyses could possibly identify ways that improve existing thermal management techniques with prioritization on fuel efficiency.

Keywords: thermal management, automatic transmission, hybrid, and systematic approach

Procedia PDF Downloads 375
3293 Assessing Trainee Radiation Exposure in Fluoroscopy-Guided Procedures: An Analysis of Hp(3)

Authors: Ava Zarif Sanayei, Sedigheh Sina

Abstract:

During fluoroscopically guided procedures, healthcare workers, especially radiology trainees, are at risk of exposure to elevated radiation exposure. It is vital to prioritize their safety in such settings. However, there is limited data on their monthly or annual doses. This study aimed to evaluate the equivalent dose to the eyes of the student trainee, utilizing LiF: Mg, Ti (TLD-100) chips at the radiology department of a hospital in Shiraz, Iran. Initially, the dosimeters underwent calibration procedures with the assistance of ISO-PTW calibrated phantoms. Following this, a set of dosimeters was prepared To determine HP(3) value for a trainee involved in the main operation room and controlled area utilized for two months. Three TLD chips were placed in a holder and attached to her eyeglasses. Upon completion of the duration, the TLDs were read out using a Harshaw TLD reader. Results revealed that Hp(3) value was 0.31±0.04 mSv. Based on international recommendations, students in radiology training above 18 have an annual dose limit of 0.6 rem (6 mSv). Assuming a 12-month workload, staff radiation exposure stayed below the annual limit. However, the Trainee workload may vary due to different deeds. This study's findings indicate the need for consistent, precise dose monitoring in IR facilities. Students can undertake supervised internships for up to 500 hours, depending on their institution. These internships take place in health-focused environments offering radiology services, such as clinics, diagnostic imaging centers, and hospitals. Failure to do so might result in exceeding occupational radiation dose limits. A 0.5 mm lead apron effectively absorbs 99% of radiation. To ensure safety, technologists and staff need to wear this protective gear whenever they are in the room during procedures. Furthermore, maintaining a safe distance from the primary beam is crucial. In cases where patients need assistance and must be held for imaging, additional protective equipment, including lead goggles, gloves, and thyroid shields, should be utilized for optimal safety.

Keywords: annual dose limits, Hp(3), individual monitoring, radiation protection, TLD-100

Procedia PDF Downloads 69
3292 Learning the Most Common Causes of Major Industrial Accidents and Apply Best Practices to Prevent Such Accidents

Authors: Rajender Dahiya

Abstract:

Investigation outcomes of major process incidents have been consistent for decades and validate that the causes and consequences are often identical. The debate remains as we continue to experience similar process incidents even with enormous development of new tools, technologies, industry standards, codes, regulations, and learning processes? The objective of this paper is to investigate the most common causes of major industrial incidents and reveal industry challenges and best practices to prevent such incidents. The author, in his current role, performs audits and inspections of a variety of high-hazard industries in North America, including petroleum refineries, chemicals, petrochemicals, manufacturing, etc. In this paper, he shares real life scenarios, examples, and case studies from high hazards operating facilities including key challenges and best practices. This case study will provide a clear understanding of the importance of near miss incident investigation. The incident was a Safe operating limit excursion. The case describes the deficiencies in management programs, the competency of employees, and the culture of the corporation that includes hazard identification and risk assessment, maintaining the integrity of safety-critical equipment, operating discipline, learning from process safety near misses, process safety competency, process safety culture, audits, and performance measurement. Failure to identify the hazards and manage the risks of highly hazardous materials and processes is one of the primary root-causes of an incident, and failure to learn from past incidents is the leading cause of the recurrence of incidents. Several investigations of major incidents discovered that each showed several warning signs before occurring, and most importantly, all were preventable. The author will discuss why preventable incidents were not prevented and review the mutual causes of learning failures from past major incidents. The leading causes of past incidents are summarized below. Management failure to identify the hazard and/or mitigate the risk of hazardous processes or materials. This process starts early in the project stage and continues throughout the life cycle of the facility. For example, a poorly done hazard study such as HAZID, PHA, or LOPA is one of the leading causes of the failure. If this step is performed correctly, then the next potential cause is. Management failure to maintain the integrity of safety critical systems and equipment. In most of the incidents, mechanical integrity of the critical equipment was not maintained, safety barriers were either bypassed, disabled, or not maintained. The third major cause is Management failure to learn and/or apply learning from the past incidents. There were several precursors before those incidents. These precursors were either ignored altogether or not taken seriously. This paper will conclude by sharing how a well-implemented operating management system, good process safety culture, and competent leaders and staff contributed to managing the risks to prevent major incidents.

Keywords: incident investigation, risk management, loss prevention, process safety, accident prevention

Procedia PDF Downloads 54
3291 Implementation of the Collaborative Learning Approach in Learning of Second Language English

Authors: Ashwini Mahesh Jagatap

Abstract:

This paper presents the language learning strategy with respect to speaking skill with collaborative learning approach. Collaborative learning has been proven to be efficient learning methodology for all kinds of students. Students are working in groups of two or more, reciprocally searching for understanding, Solutions, or meanings, or creating a product. The presentation highlights the different stages which can be implemented during actual implementation of the methodology in the class room teaching learning process.

Keywords: collaborative classroom, collaborative learning approach, language skills, traditional teaching

Procedia PDF Downloads 569
3290 Economic Impacts of Nitrogen Fertilizer Use into Tropical Pastures for Beef Cattle in Brazil

Authors: Elieder P. Romanzini, Lutti M. Delevatti, Rhaony G. Leite, Ricardo A. Reis, Euclides B. Malheiros

Abstract:

Brazilian beef cattle production systems are an important profitability source for the national gross domestic product. The main characteristic of these systems is forage utilization as the exclusive feed source. Forage utilization had been causing on owners the false feeling of low production costs. However, this low cost is followed to low profit causing a lot times worst animal index what can result in activities changes or until land sold. Aiming to evaluate economic impacts into Brazilian beef cattle systems were evaluated four nitrogen fertilizer (N) application levels (0, 90, 180 and 270 kg per hectare [kg.ha-1]). Research was developed during 2015 into Forage Crops and Grasslands section of São Paulo State University, “Júlio de Mesquita Filho” (Unesp) (Jaboticabal, São Paulo, Brazil). Pastures were seeded with Brachiaria brizantha Stapf. ‘Marandu’ (Palisade grass) handled using continuous grazing system, with variable stocking rate, sward height maintained at 25 cm. The economic evaluation was developed in rearing e finishing phases. We evaluated the cash flows inside each phase on different N levels. Economic valuations were considering: cost-effective operating (CEO), cost-total operating (CTO), gross revenue (GR), operating profit (OP) and net income (NI), every measured in US$. Complementary analyses were developed, profitability was calculated by [OP/GR]. Pay back (measured in years) was calculated considering average capital stocktaking pondered by area in use (ACS) divided by [GR-CEO]. And the internal rate of return (IRR) was calculated by 100/(pay back). Input prices were prices during 2015 and were obtained from Anuário Brasileiro da Pecuária, Centro de Estudos Avançados em Economia Aplicada and quotation in the same region of animal production (northeast São Paulo State) during the period above mentioned. Values were calculated in US$ according exchange rate US$1.00 equal R$3.34. The CEO, CTO, GR, OP and NI per hectare for each N level were respectively US$1,919.66; US$2,048.47; US$2,905.72; US$857.25 and US$986.06 to 0 kg.ha-1; US$2,403.20; US$2,551.80; US$3,530.19; US$978.39 and US$1,126.99 to 90 kg.ha-1; US$3,180.42; US$3,364.81; US$4,985.03; US$1,620.23 and US$1,804.62 to 180 kg.ha-1andUS$3,709.14; US$3,915.15; US$5,554.95; US$1,639.80 and US$1,845.81 to 270 kg.ha-1. Relationship to another economic indexes, profitability, pay back and IRR, the results were respectively 29.50%, 6.44 and 15.54% to 0 kg.ha-1; 27.72%, 6.88 and 14.54% to 90 kg.ha-1; 32.50%, 4.08 and 24.50% to 180 kg.ha-1 and 29.52%, 3.42 and 29.27% to 270 kg.ha-1. Values previously presented in this evaluation allowing to affirm that the best result was obtained to N level 270 kg.ha-1. These results among all N levels evaluated could be explained by improve occurred on stocking rate caused by increase on N level. However, a crucial information about high N level application into pastures is the efficiency of N utilization (associated to environmental impacts) that normally decrease with the increase on N level. Hence, considering all situations (efficiency of N utilization and economic results) into tropical pastures used to beef cattle production could be recommended N level equal to 180kg.ha-1, which had better profitability and cause lesser environmental impacts, proved by other studies developed in the same area.

Keywords: Brachiaria brizantha, cost-total operating, gross revenue, profitability

Procedia PDF Downloads 165
3289 Effect of Humor on Pain and Anxiety in Patients with Rheumatoi̇d Arthri̇ti̇s: A Prospective, Randomized Controlled Study

Authors: Burcu Babadağ Savaş, Nihal Orlu, Güler Balcı Alparslan, Ertuğrul Çolak, Cengiz Korkmaz

Abstract:

Introduction/objectives: We aimed to investigate the effect of humor on pain and state anxiety in patients with rheumatoid arthritis (RA) receiving biologic intravenous (IV) infusion therapy. Method: The study sample consisted of 36 patients who met the classification criteria for RA and inclusion criteria in a rheumatology outpatient clinic at a university hospital between September 2020 and November 2021. Two sample groups were formed: the intervention group (watching a comedy movie) (n=18) and the control group (n=18). The intervention group consisted of the patient watching a comedy movie of his/her choice from an archive created by the researchers during the biological IV infusion therapy (approximately 90-120 minutes). The data collection instruments used before and after the test were the descriptive identification form, the visual analog scale (VAS), and the state anxiety scale. Results: The mean VAS scores of patients in the intervention group were 5.05 ± 2.01 in the pre-test and 2.61 ± 1.91 in the post-test. The mean state anxiety scores of patients in the intervention group were 45.94 ± 9.97 in the pre-test and 34.22 ± 6.57 in the post-test. Thus, patients who watched comedy movies during biologic IV infusion therapy in the infusion center had a greater reduction in pain scores than the control group and the effect size was small. Although there was a decrease in state anxiety scores in both groups, there was no significant difference between groups and the effect size was not relevant. Conclusions: During IV infusion therapy, watching comedy movies is recommended as a nursing care intervention for reducing pain in patients with RA in cooperation with other health professionals.

Keywords: watching comedy movie, humor, pain, anxiety, nursing, care

Procedia PDF Downloads 136
3288 A Breakthrough Improvement Brought by Taxi-Calling APPs for Taxi Operation Level

Authors: Yuan-Lin Liu, Ye Li, Tian Xia

Abstract:

Taxi-calling APPs have been used widely, while brought both benefits and a variety of issues for the taxi market. Many countries do not know whether the benefits are remarkable than the issues or not. This paper established a comparison between the basic scenario (2009-2012) and a taxi-calling software usage scenario (2012-2015) to explain the impact of taxi-calling APPs. The impacts of taxi-calling APPs illustrated by the comparison results are: 1) The supply and demand distribution is more balanced, extending from the city center to the suburb. The availability of taxi service has been improved in low density areas, thin market attribute has also been improved; 2)The ratio of short distance taxi trip decreased, long distance service increased, the utilization of mileage increased, and the rate of empty decreased; 3) The popularity of taxi-calling APPs was able to reduce the average empty distance, cruise time, empty mileage rate and average times of loading passengers, can also enhance the average operating speed, improve the taxi operating level, and reduce social cost although there are some disadvantages. This paper argues that the taxi industry and government can establish an integrated third-party credit information platform based on credit evaluated by the data of the drivers’ driving behaviors to supervise the drivers. Taxi-calling APPs under fully covered supervision in the mobile Internet environment will become a new trend.

Keywords: taxi, taxi-calling APPs, credit, scenario comparison

Procedia PDF Downloads 249