Search results for: posterior distribution
5253 Revisiting the Surgical Approaches to Decompression in Quadrangular Space Syndrome: A Cadaveric Study
Authors: Sundip Charmode, Simmi Mehra, Sudhir Kushwaha, Shalom Philip, Pratik Amrutiya, Ranjna Jangal
Abstract:
Introduction: Quadrangular space syndrome involves compression of the axillary nerve and posterior circumflex humeral artery and its management in few cases, requires surgical decompression. The current study reviews the surgical approaches used in the decompression of neurovascular structures and presents our reflections and recommendations. Methods: Four human cadavers, in the Department of Anatomy were used for dissection of the Axillae and the Scapular region by the senior residents of the Department of Anatomy and Department of Orthopedics, who dissected quadrangular space in the eight upper limbs, using anterior and posterior surgical approaches. Observations: Posterior approach to identify the quadrangular space and secure its contents was recognized as the easier and much quicker method by both the Anatomy and Orthopedic residents, but it may result in increased postoperative morbidity. Whereas the anterior (Delto-pectoral) approach involves more skill but reduces postoperative morbidity. Conclusions: Anterior (Delto-pectoral) approach with suggested modifications can prove as an effective method in surgical decompression of quadrangular space syndrome. The authors suggest more cadaveric studies to facilitate anatomists and surgeons with the opportunities to practice and evaluate older and newer surgical approaches.Keywords: surgical approach, anatomical approach, decompression, axillary nerve, quadrangular space
Procedia PDF Downloads 1735252 Geometry of the Right Ventricular Outflow Tract - Clinical Significance in Electrocardiological Procedures
Authors: Marcin Jakiel, Maria Kurek, Karolina Gutkowska, Sylwia Sanakiewicz, Dominika Stolarczyk, Jakub Batko, Rafał Jakiel, Mateusz K. Hołda
Abstract:
The geometry of RVOT is extremely complicated. It is an irregular block with an ellipsoidal cross-section, whose dimensions decrease toward the pulmonary valve and measure 33.82 (IQR 30,51-39,36), 28.82 (IQR 26,11-32,22), 27.95 ± 4,11 for width [mm] and 33.41 ± 6,14, 26.99 ± 4,41, 26.91 ± 4,00 [mm] for depth, in the basal, middle and subpulmonary parts, respectively. In a sagittal section view, the RVOT heads upward and slightly backward. Its anterior perimeter has an average length of 41.96 mm and inclines to the transverse plane at an angle of 50.77° (IQR 46,53°-58,70°). In the posterior region, the RVOT is shorter (18.17mm) and flexes anteriorly. Therefore, the slope of the upper part of the rear wall to the transverse plane is an acute angle (open toward the rear) of 44,58° (IQR 37,30°-51,25°), while in the lower part it is an angle close to a right angle of 94,30°±15,44°. In addition, the thickness of the RVOT wall in the diastolic phase, at the posterior perimeter at the base, in the middle of the length and subpulmonary measure 3,80 mm ± 0,88 mm, 3,56 mm ± 0,73 mm, 3,56 mm ± 0,65 mm, respectively. In frontal cross-section, the RVOT rises on the interventricular septum, which makes it possible to distinguish the septal and supraseptal parts on its left periphery. The angles (facing the vertices to the right) of the inclination of these parts to the transverse plane are 75.5° (IQR 66,44°-81,11°) and 107.01° (IQR 99,09 – 115,23°), respectively, which allows us to conclude that the direction of the RVOT long axis changes from left to right. The above analysis shows that there is no single RVOT axis. Two axes can be distinguished, the one for the upper RVOT being more backward and leftward. The aforementioned forward deflection of the posterior wall and the RVOT's elevation over the interventricular septum, suggest that access to the subpulmonary region may be difficult. It should be emphasized that this area is often the target for ablation of ventricular arrhythmias. The small thickness of the RVOT posterior wall, with its difficult geometry, may favor its perforation into the pericardium or ascending aorta.Keywords: angle, geometry, operation access, position, RVOT, shape
Procedia PDF Downloads 1105251 The Patterns of Cross-Sentence: An Event-Related Potential Study of Mathematical Word Problem
Authors: Tien-Ching Yao, Ching-Ching Lu
Abstract:
Understanding human language processing is one of the main challenges of current cognitive neuroscience. The aims of the present study were to use a sentence decision task combined with event-related potentials to investigate the psychological reality of "cross-sentence patterns." Therefore, we take the math word problems the experimental materials and use the ERPs' P600 component to verify. In this study, the experimental material consisted of 200 math word problems with three different conditions were used ( multiplication word problems、division word problems type 1、division word problems type 2 ). Eighteen Mandarin native speakers participated in the ERPs study (14 of whom were female). The result of the grand average waveforms suggests a later posterior positivity at around 500ms - 900ms. These findings were tested statistically using repeated measures ANOVAs at the component caused by the stimulus type of different questions. Results suggest that three conditions present significant (P < 0.05) on the Mean Amplitude, Latency, and Peak Amplitude. The result showed the characteristic timing and posterior scalp distribution of a P600 effect. We interpreted these characteristic responses as the psychological reality of "cross-sentence patterns." These results provide insights into the sentence processing issues in linguistic theory and psycholinguistic models of language processing and advance our understanding of how people make sense of information during language comprehension.Keywords: language processing, sentence comprehension, event-related potentials, cross-sentence patterns
Procedia PDF Downloads 1485250 Design of Distribution Network for Gas Cylinders in Jordan
Authors: Hazem J. Smadi
Abstract:
Performance of a supply chain is directly related to a distribution network that entails the location of storing materials or products and how products are delivered to the end customer through different stages in the supply chain. This study analyses the current distribution network used for delivering gas cylinders to end customer in Jordan. Evaluation of current distribution has been conducted across customer service components. A modification on the current distribution network in terms of central warehousing in each city in the country improves the response time and customer experience.Keywords: distribution network, gas cylinder, Jordan, supply chain
Procedia PDF Downloads 4595249 The Evaluation of the Performance of Different Filtering Approaches in Tracking Problem and the Effect of Noise Variance
Authors: Mohammad Javad Mollakazemi, Farhad Asadi, Aref Ghafouri
Abstract:
Performance of different filtering approaches depends on modeling of dynamical system and algorithm structure. For modeling and smoothing the data the evaluation of posterior distribution in different filtering approach should be chosen carefully. In this paper different filtering approaches like filter KALMAN, EKF, UKF, EKS and smoother RTS is simulated in some trajectory tracking of path and accuracy and limitation of these approaches are explained. Then probability of model with different filters is compered and finally the effect of the noise variance to estimation is described with simulations results.Keywords: Gaussian approximation, Kalman smoother, parameter estimation, noise variance
Procedia PDF Downloads 4395248 Bifid Ureters: Arising Directly from the Separate Calyces and Renal Pelvis of the Kidney: A Case Report
Authors: Yuri Seu, Hyun Jin Park, Jin Seo Park, Yong-Suk Moon, HongtaeKim, Mi-Sun Hur
Abstract:
The present case report describes bifid ureters arising directly from the separate calyces and renal pelvis of the kidney. It was a single common ureter leading away from the bladder, which was separated into incompletely duplicated ureters near the level of the anterior superior iliac supine. These two branches then entered the left kidney through their own courses. Each ureter traveled anterior and posterior to the renal vein, respectively. These two ureters formed a Y-shaped pattern. One ureter coursed anterior to the renal vein with shorter length, and it terminated at the renal pelvis that was divided into major calices in approximately lower two thirds of the kidney. The other ureter coursed posterior to the renal vein with longer length, terminating at approximately the upper third of the kidney. The renal calices in the upper third of the kidney were directly connected to the posterior ureter, whereas the other major calices in the lower two thirds of the kidney formed the renal pelvis connecting to the anterior ureter. Thus, convergence of the major calices was separated according to the terminations of two ureters. These anomalous ureters were traced to the calices of the kidney, thereby providing a reference of a rare variation of the ureter. The bifid ureters arising from the separate calyces and renal pelvis should be considered by radiologists when evaluating images and diagnosing possible complications of these anomalies.Keywords: bifid ureters, kidney, major calices, renal pelvis
Procedia PDF Downloads 865247 A New Distribution and Application on the Lifetime Data
Authors: Gamze Ozel, Selen Cakmakyapan
Abstract:
We introduce a new model called the Marshall-Olkin Rayleigh distribution which extends the Rayleigh distribution using Marshall-Olkin transformation and has increasing and decreasing shapes for the hazard rate function. Various structural properties of the new distribution are derived including explicit expressions for the moments, generating and quantile function, some entropy measures, and order statistics are presented. The model parameters are estimated by the method of maximum likelihood and the observed information matrix is determined. The potentiality of the new model is illustrated by means of real life data set.Keywords: Marshall-Olkin distribution, Rayleigh distribution, estimation, maximum likelihood
Procedia PDF Downloads 5015246 The Current Situation of Ang Thong Province’s Court Doll Distribution
Authors: Phutthiwat Waiyawuththanapoom
Abstract:
This research is objected to study the pattern and channel of distribution of Ang Thong’s court doll OTOP product and try to develop the quality of distribution of the court doll product. The population of this research is 50 court doll manufacturers of Ang Thong’s court doll. The data and information was collected by using the questionnaire and use percentage, mean and standard deviation as an analysis tools. The distribution channel of Ang Thong’s court doll can be separated into 3 channels which are direct distribution from the manufacturer, via the middleman and via the co-operated manufacturing group. In the direct distribution from the manufacturer channel, it was found that the manufacturer is given the highest rate of importance to how they keep the inventory. In the distribution via the middleman channel, it was found that the manufacturer is given the highest rate of importance to the distribution efficiency. But in the distribution via the co-operated manufacturing group, it was found that the manufacturer is given the highest rate of importance to the public relationship.Keywords: distribution, court doll, Ang Thong province, business and social sciences
Procedia PDF Downloads 3175245 Biomechanics of Atalantoaxial Complex for Various Posterior Fixation Techniques
Authors: Arun C. O., Shrijith M. B., Thakur Rajesh Singh
Abstract:
The study aims to analyze and understand the biomechanical stability of the atlantoaxial complex under different posterior fixation techniques using the finite element method in the Indian context. The conventional cadaveric studies performed show heterogeneity in biomechanical properties. The finite element method being a versatile numerical tool, is being wisely used for biomechanics analysis of atlantoaxial complex. However, the biomechanics of posterior fixation techniques for an Indian subject is missing in the literature. It is essential to study in this context as the bone density and geometry of vertebrae vary from region to region, thereby requiring different screw lengths and it can affect the range of motion(ROM), stresses generated. The current study uses CT images for developing a 3D finite element model with C1-C2 geometry without ligaments. Instrumentation is added to this geometry to develop four models for four fixation techniques, namely C1-C2 TA, C1LM-C2PS, C1LM-C2Pars, C1LM-C2TL. To simulate Flexion, extension, lateral bending, axial rotation, 1.5 Nm is applied to C1 while the bottom nodes of C2 are fixed. Then Range of Motion (ROM) is compared with the unstable model(without ligaments). All the fixation techniques showed more than 97 percent reduction in the Range of Motion. The von-mises stresses developed in the screw constructs are obtained. From the studies, it is observed that Transarticular technique is most stable in Lateral Bending, C1LM-C2 Translaminar is found most stable in Flexion/extension. The Von-Mises stresses developed minimum in Trasarticular technique in lateral bending and axial rotation, whereas stress developed in C2 pars construct minimum in Flexion/ Extension. On average, the TA technique is stable in all motions and also stresses in constructs are less in TA. Tarnsarticular technique is found to be the best fixation technique for Indian subjects among the 4 methods.Keywords: biomechanics, cervical spine, finite element model, posterior fixation
Procedia PDF Downloads 1435244 Efficacy of Cool's and Rhythmic Stabilization Exercises on Scapular up Ward Rotation and Ut/Sa Ratio in Patients with Shoulder Impingement Syndrome
Authors: Mohammed Moustafa, Khaled Ayad, Waleed Reda
Abstract:
Shoulder impingement syndrome is the most common disorder of the shoulder, resulting in functional loss and disability. Objective: This study was designed to compare between the effects of scapular muscle training versus rhythmic stabilization exercises in treatment of shoulder impingement syndrome. Methods: Thirty patients participated in this study; they were assigned randomly into two experimental groups. The first experimental group (A) consisted of 15 patients with a mean age (21.87±2.72) years; they received graduated rhythmic stabilization exercises and stretching of the posterior capsule. The second experimental group (B) consisted of 15 patients with a mean age (22.27±2.94) years; they received scapular muscle training exercises in addition to stretching of the posterior capsule. Treatment was given three times per week, every other day, for four consecutive weeks. Patients have been evaluated pretreatment and post treatment for shoulder pain severity and functional disability. Results: Both groups showed highly statistical significant reduction in pain severity and functional disability measured post-treatment when compared with their corresponding values in pretreatment assessment. Conclusion: Both of rhythmic stabilization exercises and scapular muscle training are effective interventions to reduce shoulder pain severity and functional disability.Keywords: impingement syndrome, scapular exercises, rhythmic stabilization exercises, posterior capsule stretch
Procedia PDF Downloads 2405243 Anatomical Characteristics of Superior Gluteal Artery
Authors: Nawaf Al-Kharashi, Waseem Al-Talalwah, Shorok Al Dorazi, Roger Soames
Abstract:
Superior gluteal artery is one of the largest branches of posterior division of the internal iliac artery. It passes between the lumbosacral and first sacral root to escape from the pelvic cavity through the grater sciatic foramen just above the piriformis. The current study includes 41 cadaver investigates the origin and branch of the superior gluteal artery and clarify the clinical significance. In present study, the superior gluteal artery arises from the posterior division of the internal iliac artery directly in 82.5% whereas it arises indirectly as from the sciatic artery in 15.9%. However, it is congenital absence in 1.6% which is compensated by sciatic artery. The sciatic nerve gains vascular supply from superior gluteal artery in two ways either during its course or giving lateral sacral artery in 27% and lumbar branches in 1.6%. It also supplies the adductors group and iliacus via giving obturator artery in 14.3% and in 1.6% respectively. The superior gluteal artery usually passes between lumbosacral trunk and first sacral root in 82.5% whereas it does not passes the sciatic roots as it arises behind them in 15.9%. With a variability of the superior gluteal artery origin, there is a variability of sciatic nerve roots supply. Further, the superior gluteal artery arising from sciatic artery behind the sciatic roots carries a high risk of intra-pelvic bleeding in case of posterior pelvic fracture. Prolonged ligation of the superior gluteal artery which gives lateral sacral artery may result in sciatic neuropathy. Therefore, surgeons have to be aware of the superior gluteal artery variation in origin, course and branches to reduce the iatrogenic faults.Keywords: internal pudendal artery, inferior gluteal artery, superior gluteal artery, internal iliac artery. sciatic neuropathy, sciatic nerve
Procedia PDF Downloads 3505242 Application of Hyperbinomial Distribution in Developing a Modified p-Chart
Authors: Shourav Ahmed, M. Gulam Kibria, Kais Zaman
Abstract:
Control charts graphically verify variation in quality parameters. Attribute type control charts deal with quality parameters that can only hold two states, e.g., good or bad, yes or no, etc. At present, p-control chart is most commonly used to deal with attribute type data. In construction of p-control chart using binomial distribution, the value of proportion non-conforming must be known or estimated from limited sample information. As the probability distribution of fraction non-conforming (p) is considered in hyperbinomial distribution unlike a constant value in case of binomial distribution, it reduces the risk of false detection. In this study, a statistical control chart is proposed based on hyperbinomial distribution when prior estimate of proportion non-conforming is unavailable and is estimated from limited sample information. We developed the control limits of the proposed modified p-chart using the mean and variance of hyperbinomial distribution. The proposed modified p-chart can also utilize additional sample information when they are available. The study also validates the use of modified p-chart by comparing with the result obtained using cumulative distribution function of hyperbinomial distribution. The study clearly indicates that the use of hyperbinomial distribution in construction of p-control chart yields much accurate estimate of quality parameters than using binomial distribution.Keywords: binomial distribution, control charts, cumulative distribution function, hyper binomial distribution
Procedia PDF Downloads 2795241 Relationship between Left Ventricle Position and Hemodynamic Parameters during Cardiopulmonary Resuscitation in a Pig Model
Authors: Hyun Chang Kim, Yong Hun Jung, Kyung Woon Jeung
Abstract:
Background: From the viewpoint of cardiac pump theory, the area of the left ventricle (LV) subjected to compression increases as the LV lies closer to the sternum, possibly resulting in higher blood flow in patients with LV closer to the sternum. However, no study has evaluated LV position during cardiac arrest or its relationship with hemodynamic parameters during cardiopulmonary resuscitation (CPR). The objectives of this study were to determine whether the position of the LV relative to the anterior-posterior axis representing the direction of chest compression shifts during cardiac arrest and to examine the relationship between LV position and hemodynamic parameters during CPR. Methods: Subcostal view echocardiograms were obtained from 15 pigs with the transducer parallel to the long axis of the sternum before inducing ventricular fibrillation (VF) and during cardiac arrest. Computed tomography was performed in three pigs to objectively observe LV position during cardiac arrest. LV position parameters including the shortest distance between the anterior-posterior axis and the mid-point of the LV chamber (DAP-MidLV), the shortest distance between the anterior-posterior axis and the LV apex (DAP-Apex), and the area fraction of the LV located on the right side of the anterior-posterior axis (LVARight/LVATotal) were measured. Results: DAP-MidLV, DAP-Apex, and LVARight/LVATotal decreased progressively during untreated VF and basic life support (BLS), and then increased during advanced cardiovascular life support (ACLS). A repeated measures analysis of variance revealed significant time effects for these parameters. During BLS, the end-tidal carbon dioxide and systolic right atrial pressure were significantly correlated with the LV position parameters. During ACLS, systolic arterial pressure and systolic right atrial pressure were significantly correlated with DAP-MidLV and DAP-Apex. Conclusions: LV position changed significantly during cardiac arrest compared to the pre-arrest baseline. LV position during CPR had significant correlations with hemodynamic parameters.Keywords: heart arrest, cardiopulmonary resuscitation, heart ventricle, hemodynamics
Procedia PDF Downloads 1895240 A Study on Solutions to Connect Distribution Power Grid up to Renewable Energy Sources at KEPCO
Authors: Seung Yoon Hyun, Hyeong Seung An, Myeong Ho Choi, Sung Hwan Bae, Yu Jong Sim
Abstract:
In 2015, the southern part of the Korean Peninsula has 8.6 million poles, 1.25 million km power lines, and 2 million transformers, etc. It is the massive amount of distribution equipments which could cover a round-trip distance from the earth to the moon and 11 turns around the earth. These distribution equipments are spread out like capillaries and supplying power to every corner of the Korean Peninsula. In order to manage these huge power facility efficiently, KEPCO use DAS (Distribution Automation System) to operate distribution power system since 1997. DAS is integrated system that enables to remotely supervise and control breakers and switches on distribution network. Using DAS, we can reduce outage time and power loss. KEPCO has about 160,000 switches, 50%(about 80,000) of switches are automated, and 41 distribution center monitoring&control these switches 24-hour 365 days to get the best efficiency of distribution networks. However, the rapid increasing renewable energy sources become the problem in the efficient operation of distributed power system. (currently 2,400 MW, 75,000 generators operate in distribution power system). In this paper, it suggests the way to interconnect between renewable energy source and distribution power system.Keywords: distribution, renewable, connect, DAS (Distribution Automation System)
Procedia PDF Downloads 6215239 Posterior Circulation Ischemic Strokes in Olympic and Division 1 Wrestlers
Authors: Christen Kutz
Abstract:
Objective: The aim of this study is to review a case series of 4 high-level Olympic and Division 1 wrestlers who experienced debilitating posterior circulation ischemic strokes during or after a competitive wrestling event and to identify risk factors, etiology and outcomes of stroke in young, healthy elite wrestlers. Background: Stroke occurs in one in 10,000 people under age 64. In young adults, the most common causes of stroke are cardiac embolism, hypercoagulable state, and vasculopathy. One-third of these strokes occur in young, fit individuals. There is little published literature about ischemic strokes that occur in wrestlers. Based on the nature of wrestling, the risk of injury or dissection to neurovascular structures may be a possible theory, but very few case reports exist. Methodology: 4 wrestlers under the age of 44 with a known history of ischemic stroke participated in individual interviews either in person or virtually. Each of the wrestlers provided their demographic information, wrestling background, clinical presentation at the time of stroke, imaging results, identification of potential risk factors, acute treatment and recovery. Results: 3 white male Division 1 wrestlers (2 Lehigh University, 1 Lock Haven University) and 1 black male 2008 Olympian experienced posterior circulation strokes. Case #1 felt a “pop” while wrestling (lateral medullary infarct, possible vertebral artery dissection); Case #2 awoke with severe vertigo, sweating, and vomiting after wrestling the previous day (left cerebellar infarct, (+) protein S deficiency); Case #3 severe vertigo, ataxia, and sensation of impending doom after wrestling earlier that week (left cerebellar infarct, hypoplastic left vertebral artery (+) anti-cardiolipin antibodies). Case #4 severe dizziness, confusion (left cerebellar stroke, vertebral artery dissection, small PFO). Conclusion: 3 wrestlers were started on anti-platelet therapy, risk factors were modified, and returned to their sport. 1 wrestler was placed on anti-coagulation and retired from competition.Keywords: stroke, wrestling, Olympic, posterior circulation
Procedia PDF Downloads 755238 Task Kicking Performance with Biomechanical Instrumentation
Authors: T. Hirata, M. G. Silva, L. M. Rosa
Abstract:
The balance ability during task kick in soccer is a determining factor in the execution of functional movements that require a high-performance motor coordination. The current experiment explored it during an instep soccer kick and functional task kicking. Their kicking performance was measured in terms of the sway characteristics using lateral and antero-posterior balance of the center of pressure (COP) for the supporting leg and the kinematic data, the supporting leg’s knee angle. The motion was realized with one-legged stance of five male indoor soccer players and using the trigger device ball controller. The results showed large balance in antero-posterior direction than in lateral direction. However, each player adopts a different way to kick the ball, and the media-lateral displacement of the COP showed no correlation with the balance skill.Keywords: kicking performance, center of pressure, one-legged stance, balance ability
Procedia PDF Downloads 6165237 Water Distribution Uniformity of Solid-Set Sprinkler Irrigation under Low Operating Pressure
Authors: Manal Osman
Abstract:
Sprinkler irrigation system became more popular to reduce water consumption and increase irrigation efficiency. The water distribution uniformity plays an important role in the performance of the sprinkler irrigation system. The use of low operating pressure instead of high operating pressure can be achieved many benefits including energy and water saving. An experimental study was performed to investigate the water distribution uniformity of the solid-set sprinkler irrigation system under low operating pressure. Different low operating pressures (62, 82, 102 and 122 kPa) were selected. The range of operating pressure was lower than the recommended in the previous studies to investigate the effect of low pressure on the water distribution uniformity. Different nozzle diameters (4, 5, 6 and 7 mm) were used. The outdoor single sprinkler test was performed. The water distribution of single sprinkler, the coefficients of uniformity such as coefficient of uniformity (CU), distribution uniformity of low quarter (DUlq), distribution uniformity of low half (DUlh), coefficient of variation (CV) and the distribution characteristics like rotation speed, throw radius and overlapping distance are presented in this paper.Keywords: low operating pressure, sprinkler irrigation system, water distribution uniformity
Procedia PDF Downloads 5895236 Fault Location Detection in Active Distribution System
Authors: R. Rezaeipour, A. R. Mehrabi
Abstract:
Recent increase of the DGs and microgrids in distribution systems, disturbs the tradition structure of the system. Coordination between protection devices in such a system becomes the concern of the network operators. This paper presents a new method for fault location detection in the active distribution networks, independent of the fault type or its resistance. The method uses synchronized voltage and current measurements at the interconnection of DG units and is able to adapt to changes in the topology of the system. The method has been tested on a 38-bus distribution system, with very encouraging results.Keywords: fault location detection, active distribution system, micro grids, network operators
Procedia PDF Downloads 7875235 Effect of Progressive Type-I Right Censoring on Bayesian Statistical Inference of Simple Step–Stress Acceleration Life Testing Plan under Weibull Life Distribution
Authors: Saleem Z. Ramadan
Abstract:
This paper discusses the effects of using progressive Type-I right censoring on the design of the Simple Step Accelerated Life testing using Bayesian approach for Weibull life products under the assumption of cumulative exposure model. The optimization criterion used in this paper is to minimize the expected pre-posterior variance of the PTH percentile time of failures. The model variables are the stress changing time and the stress value for the first step. A comparison between the conventional and the progressive Type-I right censoring is provided. The results have shown that the progressive Type-I right censoring reduces the cost of testing on the expense of the test precision when the sample size is small. Moreover, the results have shown that using strong priors or large sample size reduces the sensitivity of the test precision to the censoring proportion. Hence, the progressive Type-I right censoring is recommended in these cases as progressive Type-I right censoring reduces the cost of the test and doesn't affect the precision of the test a lot. Moreover, the results have shown that using direct or indirect priors affects the precision of the test.Keywords: reliability, accelerated life testing, cumulative exposure model, Bayesian estimation, progressive type-I censoring, Weibull distribution
Procedia PDF Downloads 5045234 Variations and Anomalies of the Posterior Cerebral Artery in a South African Population
Authors: Karen Cilliers, Benedict J. Page
Abstract:
Limited research focuses on the anatomy of the posterior cerebral artery (PCA) and its cortical branches, even though there can be variation in the presence, size, and origin. The PCA branching pattern has not been adequately reported, and the true division point remains unclear. Anomalies of the PCA have been described in the previous literature; however, few examples have been reported. Furthermore, possible differences between right and left, sex, population and age groups may exist. Therefore, the aim of this study was to report on these aspects from a South African population. One hundred and twenty-six hemispheres were obtained consisting of 86 males and 38 females, between the ages of 22 and 84 (average 45 years of age). This comprised of three population groups, namely coloured (n=74), black (n=38), white (n=10) and two unknown cases. The PCA was injected with an isotonic saline and a colored silicone. The external diameter was measured with a digital micrometer, and length was measured with a string and a ruler. Presence and origins of the cortical branches were similar to the literature; however, duplications, triplications, and unusual origins were observed. The diameter and lengths indicated significant differences between the right and left sides, sex, population and age groups. Branching patterns were identified and compared to the prevalence from previous studies. Two fenestrations were observed in the P2A segment. The presence, size, origin, branching pattern and anomalies of the PCA were investigated in this study. The diameter and length can be significantly different, especially between the right and left-hand side. Changes in the diameter and length can be indicative of certain neuropathological conditions and can play a role in aneurysms formation. Adequate knowledge of the normal and abnormal PCA anatomy is crucial for surgery in the vicinity of the PCA. Therefore, future studies should focus on these aspects.Keywords: branching, cortical branches, fenestration, posterior cerebral artery
Procedia PDF Downloads 2235233 Posterior Thigh Compartment Syndrome Associated with Hamstring Avulsion and Antiplatelet Therapy
Authors: Andrea Gatti, Federica Coppotelli, Ma Primavera, Laura Palmieri, Umberto Tarantino
Abstract:
Aim of study: Scientific literature is scarce of studies and reviews valuing the pros and cons of the paratricipital approach for the treatment of humeral shaft fractures; the lateral paratricipital approach is a valid alternative to the classical posterior approach to the humeral shaft as it preserves both the triceps muscle and the elbow extensor mechanisms; based on our experience, this retrospective analysis aims at analyzing outcome, risks and benefits of the lateral paratricipital approach for humeral shaft fractures. Methods: Our study includes 14 patients treated between 2018 and 2019 for unilateral humeral shaft fractures: 13 with a B1 or B2 and a patient with a C fracture type (according to the AO/ATO Classification); 6 of our patients identified as male while 8 as female; age average was 57.8 years old (range 21-73 years old). A lateral paratricipital approach was performed on all 14 patients, sparing the triceps muscle by avoiding the olecranon osteotomy and by assessing the integrity and the preservation of the radial nerve; the humeral shaft fracture osteosynthesis was performed by means of plates and screws. After surgery all patients have started elbow functional rehabilitation with acceptable pain management. Post-operative follow-up has been carried out by assessing radiographs, MEPS (Mayo Elbow Performance Score) and DASH (Disability of Arm Shoulder and Hand) functional assessment and ROM of the affected joint. Results: All 14 patients had an optimal post-operative follow-up with an adequate osteosynthesis and functional rehabilitations by entirely preserving the operated elbow joint; the mean elbow ROM was 0-118.6 degree (range of 0-130) while the average MEPS score was 86 (range75-100) and 79.9 for the DASH (range 21.7-86.1). Just 2 patients suffered of temporary radial nerve apraxia, healed in the subsequent follow-ups. CONCLUSION: The lateral paratricipital approach preserve both the integrity of the triceps muscle and the elbow biomechanism but we do strongly recommend additional studies to be carried out to highlight differences between it and the classical posterior approach in treating humeral shaft fractures.Keywords: paratricepital approach, humerus shaft fracture, posterior approach humeral shaft, paratricipital postero-lateral approach
Procedia PDF Downloads 1295232 Histochemistry of Intestinal Enzymes of Juvenile Dourado Salminus brasiliensis Fed Bovine Colostrum
Authors: Debora B. Moretti, Wiolene M. Nordi, Thaline Maira P. Cruz, José Eurico P. Cyrino, Raul Machado-Neto
Abstract:
Enzyme activity was evaluated in the intestine of juvenile dourado (Salminus brasiliensis) fed with diets containing 0, 10 or 20% of lyophilized bovine colostrum (LBC) inclusion for either 30 or 60 days. The intestinal enzymes acid and alkaline phosphatase (ACP and ALP, respectively), non-specific esterase (NSE), lipase (LIP), dipeptidyl aminopeptidase IV (DAP IV) and leucine aminopeptidase (LAP) were studied using histochemistry in four intestinal segments (S1, S2, S3 and posterior intestine). Weak proteolitic activity was observed in all intestinal segments for DAP IV and LAP. The activity of NSE and LIP was also weak in all intestines, except for the moderate activity of NSE in the S2 of 20% LBC group after 30 days and in the S1 of 0% LBC group after 60 days. The ACP was detected only in the S2 and S3 of the 10% LBC group after 30 days. Moderate and strong staining was observed in the first three intestinal segments for ALP and weak activity in the posterior intestine. The activity of DAP IV, LAP and ALP were also present in the cytoplasm of the enterocytes. In the present results, bovine colostrum feeding did not cause alterations in activity of intestinal enzymes.Keywords: carnivorous fish, enterocyte, intestinal epithelium, teleost
Procedia PDF Downloads 3295231 Advanced Techniques in Robotic Mitral Valve Repair
Authors: Abraham J. Rizkalla, Tristan D. Yan
Abstract:
Purpose: Durable mitral valve repair is preferred to a replacement, avoiding the need for anticoagulation or re-intervention, with a reduced risk of endocarditis. Robotic mitral repair has been gaining favour globally as a safe, effective, and reproducible method of minimally invasive valve repair. In this work, we showcase the use of the Davinci© Xi robotic platform to perform several advanced techniques, working synergistically to achieve successful mitral repair in advanced mitral disease. Techniques: We present the case of a Barlow type mitral valve disease with a tall and redundant posterior leaflet resulting in severe mitral regurgitation and systolic anterior motion. Firstly, quadrangular resection of P2 is performed to remove the excess and redundant leaflet. Secondly, a sliding leaflet plasty of P1 and P3 is used to reconstruct the posterior leaflet. To anchor the newly formed posterior leaflet to the papillary muscle, CV-4 Goretex neochordae are fashioned using the innovative string, ruler, and bulldog technique. Finally, mitral valve annuloplasty and closure of a patent foramen ovale complete the repair. Results: There was no significant residual mitral regurgitation and complete resolution of the systolic anterior motion of the mitral valve on post operative transoesophageal echocardiography. Conclusion: This work highlights the robotic approach to complex repair techniques for advanced mitral valve disease. Familiarity with resection and sliding plasty, neochord implantation, and annuloplasty allows the modern cardiac surgeon to achieve a minimally-invasive and durable mitral valve repair when faced with complex mitral valve pathology.Keywords: robotic mitral valve repair, Barlow's valve, sliding plasty, neochord, annuloplasty, quadrangular resection
Procedia PDF Downloads 865230 The Effect of Human Capital and Oil Revenue on Income Distribution in Real Sample
Authors: Marjan Majdi, MohammadAli Moradi, Elham Samarikhalaj
Abstract:
Income distribution is one of the most topics in macro economic theories. There are many categories in economy such as income distribution that have the most influenced by economic policies. Human capital has an impact on economic growth and it has significant effect on income distributions. The results of this study confirm that the effects of oil revenue and human capital on income distribution are negative and significant but the value of the estimated coefficient is too small in a real sample in period time (1969-2006).Keywords: gini coefficient, human capital, income distribution, oil revenue
Procedia PDF Downloads 6355229 Reliability Analysis in Power Distribution System
Authors: R. A. Deshpande, P. Chandhra Sekhar, V. Sankar
Abstract:
In this paper, we discussed the basic reliability evaluation techniques needed to evaluate the reliability of distribution systems which are applied in distribution system planning and operation. Basically, the reliability study can also help to predict the reliability performance of the system after quantifying the impact of adding new components to the system. The number and locations of new components needed to improve the reliability indices to certain limits are identified and studied.Keywords: distribution system, reliability indices, urban feeder, rural feeder
Procedia PDF Downloads 7765228 Etiology and Postnatal Management of Prenatal Hydronephrosis: A Study of Two Teaching Hospitals of Khyber Pakhtunkhwa
Authors: Saima Ali, Liaqat Ali, Nasir Orakzai
Abstract:
Background: Hydronephrosis is the most common abnormal finding in the urinary tract on prenatal screening with Ultrasonography. The prenatal hydronephrosis is a diagnostic dilemma in differentiating between obstructive variant versus physiologic hydronephrosis. The assessment and prompt diagnosis of prenatal hydronephrosis is important because of the fact that untreated obstructive hydronephrosis usually leads to recurrent UTI, Urosepsis, deterioration of renal functions, non-functioning kidneys, and even end-stage renal disease. Objectives: To determine the etiology and outcome of postnatal treatment of children with prenatal hydronephrosis in two teaching hospitals of Khyber Pakhtunkhwa (KPK) Methods: It is a multicentric descriptive study that was conducted in department of Paediatrics in Kuwait teaching hospital Peshawar and Department of Urology in Institute of Kidney Diseases Hayatabad Medical Complex Peshawar from January 2008 till December 2010. Total numbers of 64 neonates were included in the study with the mean follow-up of 14.5 months. All the diagnostic data in prenatal, postnatal data, and operative and non-operative data were collected on structured Proforma and was analyzed on SPSS version 17. Results: Out of 64 patients, 39 (60.9 %) were male while 25 were female. 52 patients had unilateral while 12 patients had bilateral hydronephrosis. Based upon prenatal USG in term of AP diameter, 37 (57 %) patients had mild hydronephrosis (5-10 mm AP diameter), 14 patients had moderate hydronephrosis (10-15 mm AP diameter) while 13 patients had gross hydronephrosis (More than 15mm). Regarding etiology, 44(76 %) patients were labeled as physiologic hydronephrosis, 11 patients (9.3%) with PUJ obstruction, 5 patients with Vesicoureteric reflux (VUR) and 4 patients with posterior urethral valves. Surgery was performed in total of 15 (23.4%) patients that included open Pyeloplasty in 11 patients, Vesicostomy followed by posterior valve fulguration in 4 patients. All the patients of VUR treated medically. The severity in the grade of prenatal hydronephrosis is significantly associated with the need for definitive urological surgery p < 0.005. Ancillary procedures like percutaneous nephrostomy (PCN) were inserted 7 patients. Conclusions: Prenatal hydronephrosis is a common ailment associated with significant morbidity. Physiological Hydronephrosis and VUR can be successfully treated with medical treatment. However obstructive PUJ obstructions and posterior urethral valves require surgical correction with a good success rate.Keywords: prenatal hydronephrosis, Pelviureteric Junction (PUJ) Obstruction, vesicoureteric reflux, posterior urethral valve, renography
Procedia PDF Downloads 2465227 Investigating the Effects of Data Transformations on a Bi-Dimensional Chi-Square Test
Authors: Alexandru George Vaduva, Adriana Vlad, Bogdan Badea
Abstract:
In this research, we conduct a Monte Carlo analysis on a two-dimensional χ2 test, which is used to determine the minimum distance required for independent sampling in the context of chaotic signals. We investigate the impact of transforming initial data sets from any probability distribution to new signals with a uniform distribution using the Spearman rank correlation on the χ2 test. This transformation removes the randomness of the data pairs, and as a result, the observed distribution of χ2 test values differs from the expected distribution. We propose a solution to this problem and evaluate it using another chaotic signal.Keywords: chaotic signals, logistic map, Pearson’s test, Chi Square test, bivariate distribution, statistical independence
Procedia PDF Downloads 975226 Modeling the Current and Future Distribution of Anthus Pratensis under Climate Change
Authors: Zahira Belkacemi
Abstract:
One of the most important tools in conservation biology is information on the geographic distribution of species and the variables determining those patterns. In this study, we used maximum-entropy niche modeling (Maxent) to predict the current and future distribution of Anthus pratensis using climatic variables. The results showed that the species would not be highly affected by the climate change in shifting its distribution; however, the results of this study should be improved by taking into account other predictors, and that the NATURA 2000 protected sites will be efficient at 42% in protecting the species.Keywords: anthus pratensis, climate change, Europe, species distribution model
Procedia PDF Downloads 1435225 Classical and Bayesian Inference of the Generalized Log-Logistic Distribution with Applications to Survival Data
Authors: Abdisalam Hassan Muse, Samuel Mwalili, Oscar Ngesa
Abstract:
A generalized log-logistic distribution with variable shapes of the hazard rate was introduced and studied, extending the log-logistic distribution by adding an extra parameter to the classical distribution, leading to greater flexibility in analysing and modeling various data types. The proposed distribution has a large number of well-known lifetime special sub-models such as; Weibull, log-logistic, exponential, and Burr XII distributions. Its basic mathematical and statistical properties were derived. The method of maximum likelihood was adopted for estimating the unknown parameters of the proposed distribution, and a Monte Carlo simulation study is carried out to assess the behavior of the estimators. The importance of this distribution is that its tendency to model both monotone (increasing and decreasing) and non-monotone (unimodal and bathtub shape) or reversed “bathtub” shape hazard rate functions which are quite common in survival and reliability data analysis. Furthermore, the flexibility and usefulness of the proposed distribution are illustrated in a real-life data set and compared to its sub-models; Weibull, log-logistic, and BurrXII distributions and other parametric survival distributions with 3-parmaeters; like the exponentiated Weibull distribution, the 3-parameter lognormal distribution, the 3- parameter gamma distribution, the 3-parameter Weibull distribution, and the 3-parameter log-logistic (also known as shifted log-logistic) distribution. The proposed distribution provided a better fit than all of the competitive distributions based on the goodness-of-fit tests, the log-likelihood, and information criterion values. Finally, Bayesian analysis and performance of Gibbs sampling for the data set are also carried out.Keywords: hazard rate function, log-logistic distribution, maximum likelihood estimation, generalized log-logistic distribution, survival data, Monte Carlo simulation
Procedia PDF Downloads 2025224 Bionaut™: A Minimally Invasive Microsurgical Platform to Treat Non-Communicating Hydrocephalus in Dandy-Walker Malformation
Authors: Suehyun Cho, Darrell Harrington, Florent Cros, Olin Palmer, John Caputo, Michael Kardosh, Eran Oren, William Loudon, Alex Kiselyov, Michael Shpigelmacher
Abstract:
The Dandy-Walker malformation (DWM) represents a clinical syndrome manifesting as a combination of posterior fossa cyst, hypoplasia of the cerebellar vermis, and obstructive hydrocephalus. Anatomic hallmarks include hypoplasia of the cerebellar vermis, enlargement of the posterior fossa, and cystic dilatation of the fourth ventricle. Current treatments of DWM, including shunting of the cerebral spinal fluid ventricular system and endoscopic third ventriculostomy (ETV), are frequently clinically insufficient, require additional surgical interventions, and carry risks of infections and neurological deficits. Bionaut Labs develops an alternative way to treat Dandy-Walker Malformation (DWM) associated with non-communicating hydrocephalus. We utilize our discreet microsurgical Bionaut™ particles that are controlled externally and remotely to perform safe, accurate, effective fenestration of the Dandy-Walker cyst, specifically in the posterior fossa of the brain, to directly normalize intracranial pressure. Bionaut™ allows for complex non-linear trajectories not feasible by any conventional surgical techniques. The microsurgical particle safely reaches targets in the lower occipital section of the brain. Bionaut™ offers a minimally invasive surgical alternative to highly involved posterior craniotomy or shunts via direct fenestration of the fourth ventricular cyst at the locus defined by the individual anatomy. Our approach offers significant advantages over the current standards of care in patients exhibiting anatomical challenge(s) as a manifestation of DWM, and therefore, is intended to replace conventional therapeutic strategies. Current progress, including platform optimization, Bionaut™ control, and real-time imaging and in vivo safety studies of the Bionauts™ in large animals, specifically the spine and the brain of ovine models, will be discussed.Keywords: Bionaut™, cerebral spinal fluid, CSF, cyst, Dandy-Walker, fenestration, hydrocephalus, micro-robot
Procedia PDF Downloads 221