Search results for: left ventricular assist device

3747 Cardiac Protective Effect of Olive Oil against Ischemia Reperfusion- Induced Cardiac Arrhythmias in Isolated Diabetic Rat Hearts

Authors: Ishfaq A. Bukhari, Bassem Yousef Sheikh, Abdulrahman Almotrefi, Osama Yousaf, Amer Mahmood

Abstract:

Olive oil is the primary source of fat in the Mediterranean diet which is associated with a low mortality for cardiovascular disease. Olive oil is rich in monounsaturated fatty acids, and has been reported for variety of beneficial cardiovascular effects including blood pressure lowering, anti-platelet, anti-diabetic and anti-inflammatory effects. Growing number evidences from preclinical and clinical studies have shown that olive oil improves insulin resistance, decrease vessels stiffness and prevent thromboembolism. We evaluated the effects of olive against streptozotocin-induced physiological disorders in the animal models of diabetes and ischemia and reperfusion (I/R)- induced cardiac arrhythmias. Diabetes was induced in male rats with a single intraperitoneal injection of streptozotocin (60 mg/kg), rats were treated for two months with olive oil (1 ml/kg p.o). Control animals received saline. Blood glucose, body weight were monitored every 14 days. At the end of the treatment rats were sacrificed hearts were isolated for mounting on langedorff’s apparatus. The blood glucose and body weight was not significantly different in the control and olive treated animals. The control diabetic animals exhibited 100% incidence of I/R –induced ventricular fibrillation which was reduced to 0% with olive oil, treatment. The duration of ventricular fibrillation reduced from 98.8± 2.3 (control) to 0 seconds in the olive oil treated group. Diltiazem, a calcium channel blocker (1 µm/L) showed similar results and protected the I/R-induced cardiac disorders. The biochemical analysis of the cardiac tissues showed that diabetes and I/R produce marked pathological changes in the cardiomyocytes including decreased glutathione (GSH) and increased oxidative stress (Malondialdehyde; MDA). Pretreatment of animals with olive oil (1 ml/kg p.o) increased GSH and MDA levels. Olive oil also improved the diabetic-induced histopathological changes in the cardiomyocytes. These finding indicates that olive possesses cardiac protective properties. Further studies are under way in our lab to explore the mechanism of the cardio-protective effect of olive oil.

Keywords: diabeties, ischemia-reperfusion, olive oil, rats heart

Procedia PDF Downloads 446
3746 Smart Help at the Workplace for Persons with Disabilities (SHW-PWD)

Authors: Ghassan Kbar, Shady Aly, Ibrahim Alsharawy, Akshay Bhatia, Nur Alhasan, Ronaldo Enriquez

Abstract:

The Smart Help for persons with disability (PWD) is a part of the project SMARTDISABLE which aims to develop relevant solution for PWD that target to provide an adequate workplace environment for them. It would support PWD needs smartly through smart help to allow them access to relevant information and communicate with other effectively and flexibly, and smart editor that assist them in their daily work. It will assist PWD in knowledge processing and creation as well as being able to be productive at the work place. The technical work of the project involves design of a technological scenario for the Ambient Intelligence (AmI) - based assistive technologies at the workplace consisting of an integrated universal smart solution that suits many different impairment conditions and will be designed to empower the Physically disabled persons (PDP) with the capability to access and effectively utilize the ICTs in order to execute knowledge rich working tasks with minimum efforts and with sufficient comfort level. The proposed technology solution for PWD will support voice recognition along with normal keyboard and mouse to control the smart help and smart editor with dynamic auto display interface that satisfies the requirements for different PWD group. In addition, a smart help will provide intelligent intervention based on the behavior of PWD to guide them and warn them about possible misbehavior. PWD can communicate with others using Voice over IP controlled by voice recognition. Moreover, Auto Emergency Help Response would be supported to assist PWD in case of emergency. This proposed technology solution intended to make PWD very effective at the work environment and flexible using voice to conduct their tasks at the work environment. The proposed solution aims to provide favorable outcomes that assist PWD at the work place, with the opportunity to participate in PWD assistive technology innovation market which is still small and rapidly growing as well as upgrading their quality of life to become similar to the normal people at the workplace. Finally, the proposed smart help solution is applicable in all workplace setting, including offices, manufacturing, hospital, etc.

Keywords: ambient intelligence, ICT, persons with disability PWD, smart application, SHW

Procedia PDF Downloads 395
3745 Monitorization of Junction Temperature Using a Thermal-Test-Device

Authors: B. Arzhanov, A. Correia, P. Delgado, J. Meireles

Abstract:

Due to the higher power loss levels in electronic components, the thermal design of PCBs (Printed Circuit Boards) of an assembled device becomes one of the most important quality factors in electronics. Nonetheless, some of leading causes of the microelectronic component failures are due to higher temperatures, the leakages or thermal-mechanical stress, which is a concern, is the reliability of microelectronic packages. This article presents an experimental approach to measure the junction temperature of exposed pad packages. The implemented solution is in a prototype phase, using a temperature-sensitive parameter (TSP) to measure temperature directly on the die, validating the numeric results provided by the Mechanical APDL (Ansys Parametric Design Language) under same conditions. The physical device-under-test is composed by a Thermal Test Chip (TTC-1002) and assembly in a QFN cavity, soldered to a test-board according to JEDEC Standards. Monitoring the voltage drop across a forward-biased diode, is an indirectly method but accurate to obtain the junction temperature of QFN component with an applied power range between 0,3W to 1.5W. The temperature distributions on the PCB test-board and QFN cavity surface were monitored by an infra-red thermal camera (Goby-384) controlled and images processed by the Xeneth software. The article provides a set-up to monitorize in real-time the junction temperature of ICs, namely devices with the exposed pad package (i.e. QFN). Presenting the PCB layout parameters that the designer should use to improve thermal performance, and evaluate the impact of voids in solder interface in the device junction temperature.

Keywords: quad flat no-Lead packages, exposed pads, junction temperature, thermal management and measurements

Procedia PDF Downloads 266
3744 Photoimpedance Spectroscopy Analysis of Planar and Nano-Textured Thin-Film Silicon Solar Cells

Authors: P. Kumar, D. Eisenhauer, M. M. K. Yousef, Q. Shi, A. S. G. Khalil, M. R. Saber, C. Becker, T. Pullerits, K. J. Karki

Abstract:

In impedance spectroscopy (IS) the response of a photo-active device is analysed as a function of ac bias. It is widely applied in a broad class of material systems and devices. It gives access to fundamental mechanisms of operation of solar cells. We have implemented a method of IS where we modulate the light instead of the bias. This scheme allows us to analyze not only carrier dynamics but also impedance of device locally. Here, using this scheme, we have measured the frequency-dependent photocurrent response of the thin-film planar and nano-textured Si solar cells using this method. Photocurrent response is measured in range of 50 Hz to 50 kHz. Bode and Nyquist plots are used to determine characteristic lifetime of both the cells. Interestingly, the carrier lifetime of both planar and nano-textured solar cells depend on back and front contact positions. This is due to either heterogeneity of device or contacts are not optimized. The estimated average lifetime is found to be shorter for the nano-textured cell, which could be due to the influence of the textured interface on the carrier relaxation dynamics.

Keywords: carrier lifetime, impedance, nano-textured, photocurrent

Procedia PDF Downloads 213
3743 Comparative Efficacy of Angiotensin Converting Enzymes Inhibitors and Angiotensin Receptor Blockers in Patients with Heart Failure in Tanzania: A Prospective Cohort Study

Authors: Mark P. Mayala, Henry Mayala, Khuzeima Khanbhai

Abstract:

Background: Heart failure has been a rising concern in Tanzania. New drugs have been introduced, including the group of drugs called Angiotensin receptor Neprilysin Inhibitor (ARNI), but due to their high cost, angiotensin-converting enzymes inhibitors (ACEIs) and Angiotensin receptor blockers (ARBs) have been mostly used in Tanzania. However, according to our knowledge, the efficacy comparison of the two groups is yet to be studied in Tanzania. The aim of this study was to compare the efficacy of ACEIs and ARBs among patients with heart failure. Methodology: This was a hospital-based prospective cohort study done at Jakaya Kikwete Cardiac Institution (JKCI), Tanzania, from June to December 2020. Consecutive enrollment was done until fulfilling the inclusion criteria. Clinical details were measured at baseline. We assessed the relationship between ARBs and ACEIs users with N-terminal pro-brain natriuretic peptide (NT pro-BNP) levels at admission and at 1-month follow-up using a chi-square test. A Kaplan-Meier curve was used to estimate the survival time of the two groups. Results: 155 HF patients were enrolled, with a mean age of 48 years, whereby 52.3% were male, and their mean left ventricular ejection fraction (LVEF) was 37.3%. 52 (33.5%) heart failure patients were on ACEIs, 57 (36.8%) on ARBs, and 46 (29.7%) were neither using ACEIs nor ARBs. At least half of the patients did not receive a guideline-directed medical therapy (GDMT), with only 82 (52.9%) receiving a GDMT. A drop in NT pro-BNP levels was observed during admission and at 1-month follow-up on both groups, from 6389.2 pg/ml to 4000.1 pg/ml for ARB users and 5877.7 pg/ml to 1328.2 pg/ml for the ACEIs users. There was no statistical difference between the two groups when estimated by the Kaplan-Meier curve, though more deaths were observed in those who were neither on ACEIs nor ARBs, with a calculated P value of 0.01. Conclusion: This study demonstrates that ACEIs have more efficacy and overall better clinical outcome than ARBs, but this should be taken under the patient-based case, considering the side effects of ACEIs and patients’ adherence.

Keywords: angiotensin converting enzymes inhibitors, angiotensin receptor blockers, guideline direct medical therapy, N-terminal pro-brain natriuretic peptide

Procedia PDF Downloads 62
3742 Comprehensive Study of X-Ray Emission by APF Plasma Focus Device

Authors: M. Habibi

Abstract:

The time-resolved studies of soft and hard X-ray were carried out over a wide range of argon pressures by employing an array of eight filtered photo PIN diodes and a scintillation detector, simultaneously. In 50% of the discharges, the soft X-ray is seen to be emitted in short multiple pulses corresponding to different compression, whereas it is a single pulse for hard X-rays corresponding to only the first strong compression. It should be stated that multiple compressions dominantly occur at low pressures and high pressures are mostly in the single compression regime. In 43% of the discharges, at all pressures except for optimum pressure, the first period is characterized by two or more sharp peaks.The X–ray signal intensity during the second and subsequent compressions is much smaller than the first compression.

Keywords: plasma focus device, SXR, HXR, Pin-diode, argon plasma

Procedia PDF Downloads 387
3741 Effect of Nicorandil, Bone Marrow-Derived Mesenchymal Stem Cells and Their Combination in Isoproterenol-Induced Heart Failure in Rats

Authors: Sarah Elsayed Mohammed, Lamiaa Ahmed Ahmed, Mahmoud Mohammed Khattab

Abstract:

Aim: The aim of the present study was to investigate whether combined nicorandil and bone marrow-derived mesenchymal stem cells (BMDMSC) treatment could offer an additional benefit in ameliorating isoproterenol (ISO)-induced heart failure in rats. Methods: ISO (85 and 170 mg/kg/day) was injected subcutaneously for 2 successive days, respectively. By day 3, electrocardiographic changes were recorded and serum was separated for determination of CK-MB level for confirmation of myocardial damage. Nicorandil (3 mg/kg/day) was then given orally with or without a single i.v. BMDMSC administration. Electrocardiography and echocardiography were recorded 2 weeks after beginning of treatment. Rats were then sacrificed and ventricles were isolated for estimation of vascular endothelial growth factor (VEGF), tumor necrosis factor-alpha (TNF-α) and transforming growth factor-beta (TGF-β) contents, caspase-3 activity as well as inducible nitric oxide synthase (iNOS) and connexin-43 protein expressions. Moreover, histological analysis of myocardial fibrosis was performed and cryosections were done for estimation of homing of BMDMSC. Results: ISO induced a significant increase in ventricles/body weight ratio, left ventricular end diastolic (LVEDD) and systolic dimensions (LVESD), ST segment and QRS duration. Moreover, myocardial fibrosis as well as VEGF, TNF-α and TGF-β contents were significantly increased. On the other hand, connexin-43 protein expression was significantly decreased, while caspase-3 and iNOS protein expressions were significantly increased. Combined therapy provided additional improvement compared to cell treatment alone towards reducing cardiac hypertrophy, fibrosis and inflammation. Furthermore, combined therapy induced significant increase in angiogenesis and BMDMSC homing and prevented ISO induced changes in iNOS, connexin-43 and caspase-3 protein expressions. Conclusion: Combined nicorandil/BMDMSC treatment was superior to BMDMSC alone towards preventing ISO-induced heart failure in rats.

Keywords: fibrosis, isoproterenol, mesenchymal stem cells, nicorandil

Procedia PDF Downloads 504
3740 Two-Dimensional Material-Based Negative Differential Resistance Device with High Peak-to- Valley Current Ratio for Multi-Valued Logic Circuits

Authors: Kwan-Ho Kim, Jin-Hong Park

Abstract:

The multi-valued logic (MVL) circuits, which can handle more than two logic states, are one of the promising solutions to overcome the bit density limitations of conventional binary logic systems. Recently, tunneling devices such as Esaki diode and resonant tunneling diode (RTD) have been extensively explored to construct the MVL circuits. These tunneling devices present a negative differential resistance (NDR) phenomenon in which a current decreases as a voltage increases in a specific applied voltage region. Due to this non-monotonic current behavior, the tunneling devices have more than two threshold voltages, consequently enabling construction of MVL circuits. Recently, the emergence of two dimensional (2D) van der Waals (vdW) crystals has opened up the possibility to fabricate such tunneling devices easily. Owing to the defect-free surface of the 2D crystals, a very abrupt junction interface could be formed through a simple stacking process, which subsequently allowed the implementation of a high-performance tunneling device. Here, we report a vdW heterostructure based tunneling device with multiple threshold voltages, which was fabricated with black phosphorus (BP) and hafnium diselenide (HfSe₂). First, we exfoliated BP on the SiO₂ substrate and then transferred HfSe₂ on BP using dry transfer method. The BP and HfSe₂ form type-Ⅲ heterojunction so that the highly doped n+/p+ interface can be easily implemented without additional electrical or chemical doping process. Owing to high natural doping at the junction, record high peak to valley ratio (PVCR) of 16 was observed to the best our knowledge in 2D materials based NDR device. Furthermore, based on this, we first demonstrate the feasibility of the ternary latch by connecting two multi-threshold voltage devices in series.

Keywords: two dimensional van der Waals crystal, multi-valued logic, negative differential resistnace, tunneling device

Procedia PDF Downloads 188
3739 Development of Affordable and Reliable Diagnostic Tools to Record Vital Parameters for Improving Health Care in Low Resources Settings

Authors: Mannan Mridha, Usama Gazay, Kosovare V. Aslani, Hugo Linder, Alice Ravizza, Carmelo de Maria

Abstract:

In most developing countries, although the vast majority of the people are living in the rural areas, the qualified medical doctors are not available there. Health care workers and paramedics, called village doctors, informal healthcare providers, are largely responsible for the rural medical care. Mishaps due to wrong diagnosis and inappropriate medication have been causing serious suffering that is preventable. While innovators have created many devices, the vast majority of these technologies do not find applications to address the needs and conditions in low-resource settings. The primary motive is to address the acute lack of affordable medical technologies for the poor people in low-resource settings. A low cost smart medical device that is portable, battery operated and can be used at any point of care has been developed to detect breathing rate, electrocardiogram (ECG) and arterial pulse rate to improve diagnosis and monitoring of patients and thus improve care and safety. This simple and easy to use smart medical device can be used, managed and maintained effectively and safely by any health worker with some training. In order to empower the health workers and village doctors, our device is being further developed to integrate with ICT tools like smart phones and connect to the medical experts wherever available, to manage the serious health problems.

Keywords: e-health for low resources settings, health awareness education, improve patient care and safety, smart and affordable medical device

Procedia PDF Downloads 166
3738 Epicardial Fat Necrosis in a Young Female: A Case Report

Authors: Tayyibah Shah Alam, Joe Thomas, Nayantara Shenoy

Abstract:

Presenting a case that we would like to share, the answer is straight forward but the path taken to get to the diagnosis is where it gets interesting. A 31-year-old lady presented to the Rheumatology Outpatient department with left-sided chest pain associated with left-sided elbow joint pain intensifying over the last 2 days. She had been having a prolonged history of chest pain with minimal intensity since 2016. The pain is intermittent in nature. Aggravated while exerting, lifting heavy weights and lying down. Relieved while sitting. Her physical examination and laboratory tests were within normal limits. An electrocardiogram (ECG) showed normal sinus rhythm and a chest X-ray with no significant abnormality was noted. The primary suspicion was recurrent costochondritis. Cardiac blood inflammatory markers and Echo were normal, ruling out ACS. CT chest and MRI Thorax contrast showed small ill-defined STIR hyperintensity with thin peripheral enhancement in the anterior mediastinum in the left side posterior to the 5th costal cartilage and anterior to the pericardium suggestive of changes in the fat-focal panniculitis. Confirming the diagnosis as Epicardial fat necrosis. She was started on Colchicine and Nonsteroidal anti-inflammatory drugs for 2-3 weeks, following which a repeat CT showed resolution of the lesion and improvement in her. It is often under-recognized or misdiagnosed. CT scan was collectively used to establish the diagnosis. Making the correct diagnosis prospectively alleviates unnecessary testing in favor of conservative management.

Keywords: EFN, panniculitis, unknown etiology, recurrent chest pain

Procedia PDF Downloads 74
3737 A More Powerful Test Procedure for Multiple Hypothesis Testing

Authors: Shunpu Zhang

Abstract:

We propose a new multiple test called the minPOP test for testing multiple hypotheses simultaneously. Under the assumption that the test statistics are independent, we show that the minPOP test has higher global power than the existing multiple testing methods. We further propose a stepwise multiple-testing procedure based on the minPOP test and two of its modified versions (the Double Truncated and Left Truncated minPOP tests). We show that these multiple tests have strong control of the family-wise error rate (FWER). A method for finding the p-values of the proposed tests after adjusting for multiplicity is also developed. Simulation results show that the Double Truncated and Left Truncated minPOP tests, in general, have a higher number of rejections than the existing multiple testing procedures.

Keywords: multiple test, single-step procedure, stepwise procedure, p-value for multiple testing

Procedia PDF Downloads 44
3736 Copy Number Variants in Children with Non-Syndromic Congenital Heart Diseases from Mexico

Authors: Maria Lopez-Ibarra, Ana Velazquez-Wong, Lucelli Yañez-Gutierrez, Maria Araujo-Solis, Fabio Salamanca-Gomez, Alfonso Mendez-Tenorio, Haydeé Rosas-Vargas

Abstract:

Congenital heart diseases (CHD) are the most common congenital abnormalities. These conditions can occur as both an element of distinct chromosomal malformation syndromes or as non-syndromic forms. Their etiology is not fully understood. Genetic variants such copy number variants have been associated with CHD. The aim of our study was to analyze these genomic variants in peripheral blood from Mexican children diagnosed with non-syndromic CHD. We included 16 children with atrial and ventricular septal defects and 5 healthy subjects without heart malformations as controls. To exclude the most common heart disease-associated syndrome alteration, we performed a fluorescence in situ hybridization test to identify the 22q11.2, responsible for congenital heart abnormalities associated with Di-George Syndrome. Then, a microarray based comparative genomic hybridization was used to identify global copy number variants. The identification of copy number variants resulted from the comparison and analysis between our results and data from main genetic variation databases. We identified copy number variants gain in three chromosomes regions from pediatric patients, 4q13.2 (31.25%), 9q34.3 (25%) and 20q13.33 (50%), where several genes associated with cellular, biosynthetic, and metabolic processes are located, UGT2B15, UGT2B17, SNAPC4, SDCCAG3, PMPCA, INPP6E, C9orf163, NOTCH1, C20orf166, and SLCO4A1. In addition, after a hierarchical cluster analysis based on the fluorescence intensity ratios from the comparative genomic hybridization, two congenital heart disease groups were generated corresponding to children with atrial or ventricular septal defects. Further analysis with a larger sample size is needed to corroborate these copy number variants as possible biomarkers to differentiate between heart abnormalities. Interestingly, the 20q13.33 gain was present in 50% of children with these CHD which could suggest that alterations in both coding and non-coding elements within this chromosomal region may play an important role in distinct heart conditions.

Keywords: aCGH, bioinformatics, congenital heart diseases, copy number variants, fluorescence in situ hybridization

Procedia PDF Downloads 266
3735 Cardiac Pacemaker in a Patient Undergoing Breast Radiotherapy-Multidisciplinary Approach

Authors: B. Petrović, M. Petrović, L. Rutonjski, I. Djan, V. Ivanović

Abstract:

Objective: Cardiac pacemakers are very sensitive to radiotherapy treatment from two sources: electromagnetic influence from the medical linear accelerator producing ionizing radiation- influencing electronics within the pacemaker, and the absorption of dose to the device. On the other hand, patients with cardiac pacemakers at the place of a tumor are rather rare, and single clinic hardly has experience with the management of such patients. The widely accepted international guidelines for management of radiation oncology patients recommend that these patients should be closely monitored and examined before, during and after radiotherapy treatment by cardiologist, and their device and condition followed up. The number of patients having both cancer and pacemaker, is growing every year, as both cancer incidence, as well as cardiac diseases incidence, are inevitably growing figures. Materials and methods: Female patient, age 69, was diagnozed with valvular cardiomyopathy and got implanted a pacemaker in 2005 and prosthetic mitral valve in 1993 (cancer was diagnosed in 2012). She was stable cardiologically and came to radiation therapy department with the diagnosis of right breast cancer, with the tumor in upper lateral quadrant of the right breast. Since she had all lymph nodes positive (28 in total), she had to have irradiated the supraclavicular region, as well as the breast with the tumor bed. She previously received chemotherapy, approved by the cardiologist. The patient was estimated to be with the high risk as device was within the field of irradiation, and the patient had high dependence on her pacemaker. The radiation therapy plan was conducted as 3D conformal therapy. The delineated target was breast with supraclavicular region, where the pacemaker was actually placed, with the addition of a pacemaker as organ at risk, to estimate the dose to the device and its components as recommended, and the breast. The targets received both 50 Gy in 25 fractions (where 20% of a pacemaker received 50 Gy, and 60% of a device received 40 Gy). The electrode to the heart received between 1 Gy and 50 Gy. Verification of dose planned and delivered was performed. Results: Evaluation of the patient status according to the guidelines and especially evaluation of all associated risks to the patient during treatment was done. Patient was irradiated by prescribed dose and followed up for the whole year, with no symptoms of failure of the pacemaker device during, or after treatment in follow up period. The functionality of a device was estimated to be unchanged, according to the parameters (electrode impedance and battery energy). Conclusion: Patient was closely monitored according to published guidelines during irradiation and afterwards. Pacemaker irradiated with the full dose did not show any signs of failure despite recommendations data, but in correlation with other published data.

Keywords: cardiac pacemaker, breast cancer, radiotherapy treatment planning, complications of treatment

Procedia PDF Downloads 416
3734 Numerical Modeling and Experimental Analysis of a Pallet Isolation Device to Protect Selective Type Industrial Storage Racks

Authors: Marcelo Sanhueza Cartes, Nelson Maureira Carsalade

Abstract:

This research evaluates the effectiveness of a pallet isolation device for the protection of selective-type industrial storage racks. The device works only in the longitudinal direction of the aisle, and it is made up of a platform installed on the rack beams. At both ends, the platform is connected to the rack structure by means of a spring-damper system working in parallel. A system of wheels is arranged between the isolation platform and the rack beams in order to reduce friction, decoupling of the movement and improve the effectiveness of the device. The latter is evaluated by the reduction of the maximum dynamic responses of basal shear load and story drift in relation to those corresponding to the same rack with the traditional construction system. In the first stage, numerical simulations of industrial storage racks were carried out with and without the pallet isolation device. The numerical results allowed us to identify the archetypes in which it would be more appropriate to carry out experimental tests, thus limiting the number of trials. In the second stage, experimental tests were carried out on a shaking table to a select group of full-scale racks with and without the proposed device. The movement simulated by the shaking table was based on the Mw 8.8 magnitude earthquake of February 27, 2010, in Chile, registered at the San Pedro de la Paz station. The peak ground acceleration (PGA) was scaled in the frequency domain to fit its response spectrum with the design spectrum of NCh433. The experimental setup contemplates the installation of sensors to measure relative displacement and absolute acceleration. The movement of the shaking table with respect to the ground, the inter-story drift of the rack and the pallets with respect to the rack structure were recorded. Accelerometers redundantly measured all of the above in order to corroborate measurements and adequately capture low and high-frequency vibrations, whereas displacement and acceleration sensors are respectively more reliable. The numerical and experimental results allowed us to identify that the pallet isolation period is the variable with the greatest influence on the dynamic responses considered. It was also possible to identify that the proposed device significantly reduces both the basal cut and the maximum inter-story drift by up to one order of magnitude.

Keywords: pallet isolation system, industrial storage racks, basal shear load, interstory drift.

Procedia PDF Downloads 55
3733 Urea and Starch Detection on a Paper-Based Microfluidic Device Enabled on a Smartphone

Authors: Shashank Kumar, Mansi Chandra, Ujjawal Singh, Parth Gupta, Rishi Ram, Arnab Sarkar

Abstract:

Milk is one of the basic and primary sources of food and energy as we start consuming milk from birth. Hence, milk quality and purity and checking the concentration of its constituents become necessary steps. Considering the importance of the purity of milk for human health, the following study has been carried out to simultaneously detect and quantify the different adulterants like urea and starch in milk with the help of a paper-based microfluidic device integrated with a smartphone. The detection of the concentration of urea and starch is based on the principle of colorimetry. In contrast, the fluid flow in the device is based on the capillary action of porous media. The microfluidic channel proposed in the study is equipped with a specialized detection zone, and it employs a colorimetric indicator undergoing a visible color change when the milk gets in touch or reacts with a set of reagents which confirms the presence of different adulterants in the milk. In our proposed work, we have used iodine to detect the percentage of starch in the milk, whereas, in the case of urea, we have used the p-DMAB. A direct correlation has been found between the color change intensity and the concentration of adulterants. A calibration curve was constructed to find color intensity and subsequent starch and urea concentration. The device has low-cost production and easy disposability, which make it highly suitable for widespread adoption, especially in resource-constrained settings. Moreover, a smartphone application has been developed to detect, capture, and analyze the change in color intensity due to the presence of adulterants in the milk. The low-cost nature of the smartphone-integrated paper-based sensor, coupled with its integration with smartphones, makes it an attractive solution for widespread use. They are affordable, simple to use, and do not require specialized training, making them ideal tools for regulatory bodies and concerned consumers.

Keywords: paper based microfluidic device, milk adulteration, urea detection, starch detection, smartphone application

Procedia PDF Downloads 39
3732 Mesotrione and Tembotrione Applied Alone or in Tank-Mix with Atrazine on Weed Control in Elephant Grass

Authors: Alexandre M. Brighenti

Abstract:

The experiment was carried out in Valença, Rio de Janeiro State, Brazil, to evaluate the selectivity and weed control of carotenoid biosynthesis inhibiting herbicides applied alone or in combination with atrazine in elephant grass crop. The treatments were as follows: mesotrione (0.072 and 0.144 kg ha-1 + 0.5% v/v mineral oil - Assist®), tembotrione (0.075 and 0.100 kg ha-1 + 0.5% v/v mineral oil - Aureo®), atrazine + mesotrione (1.25 + 0.072 kg ha-1 + 0.5% v/v mineral oil - Assist®), atrazine + tembotrione (1.25 + 0.100 kg ha-1 + 0.5% v/v mineral oil - Aureo®), atrazine + mesotrione (1.25 + 0.072 kg ha-1), atrazine + tembotrione (1.25 + 0.100 kg ha-1) and two controls (hoed and unhoed check). Two application rates of mesotrione with the addition of mineral oil or the tank mixture of atrazine plus mesotrione, with or without the addition of mineral oil, did not provide injuries capable to reduce elephant grass forage yield. Tembotrione was phytotoxic to elephant grass when applied with mineral oil. Atrazine and tembotrione in a tank-mix, with or without mineral oil, were also phytotoxic to elephant grass. All treatments provided satisfactory weed control.

Keywords: forage, Napier grass, pasture, Pennisetum purpureum, weeds

Procedia PDF Downloads 257
3731 A Fuzzy Decision Making Approach for Supplier Selection in Healthcare Industry

Authors: Zeynep Sener, Mehtap Dursun

Abstract:

Supplier evaluation and selection is one of the most important components of an effective supply chain management system. Due to the expanding competition in healthcare, selecting the right medical device suppliers offers great potential for increasing quality while decreasing costs. This paper proposes a fuzzy decision making approach for medical supplier selection. A real-world medical device supplier selection problem is presented to illustrate the application of the proposed decision methodology.

Keywords: fuzzy decision making, fuzzy multiple objective programming, medical supply chain, supplier selection

Procedia PDF Downloads 422
3730 Microscopic Examination of the Pre-Hatching Development of the Chicken Ovary

Authors: Mohamed Alsafy, Samir El-Gendy, Ashraf Karkoura, Doha Shokry

Abstract:

The purpose of the current study was to investigate the development of the chicken ovary. One hundred fertilized egg of Alexandria breed of chicken used. The whole embryo has undergone the light microscopic examination at HH20 (E.3), HH21 (E.3.5), HH23 (E.4), HH29 (E.6) and HH34 (E.8). The ovary has undergone the light microscopic examination at HH38 (E.12) and HH42 (E.16), SEM at HH26 (E.5), HH29 (E.6), HH36 (E.10), HH38 (E.12), HH39 (E.13) and HH42 (E.16), TEM at HH38 (E.12) and HH42 (E.16). The genital ridge appeared by a thickening of the coelomic epithelium medioventral surface of the developing mesonephroi at HH20 (E.3). The boundaries of the undifferentiating gonads defined clearly separated from the mesonephroi. The undifferentiated gonads bulged as a distinct organ in the coelomic cavity at HH23 (E.4). At the initial stages of the gonadogenesis, the germinal epithelium was stratified squamous epithelium. The PGCs appeared at the genital ridge at HH21 (E.3.5). The PGCs observed at the dorsal mesentery with few microvilli and showed positive PAS reaction due to the glycogen content in their cytoplasm. The left-right gonadal asymmetry firstly detected by the number of PGCs migrating toward the left gonadal ridge more than the right at HH20 (E.3) and the macroscopic examination of gonadal asymmetry began at HH34 (E.8). The left ovary appeared a smooth rod-shape, its stroma showed lipid droplets, and its parenchyma showed an extensive arrangement of interstitial cords at HH42 (E.16).

Keywords: ovary, Alexandria chicken, light microscopy, SEM, TEM

Procedia PDF Downloads 288
3729 Design of a Low-Cost, Portable, Sensor Device for Longitudinal, At-Home Analysis of Gait and Balance

Authors: Claudia Norambuena, Myissa Weiss, Maria Ruiz Maya, Matthew Straley, Elijah Hammond, Benjamin Chesebrough, David Grow

Abstract:

The purpose of this project is to develop a low-cost, portable sensor device that can be used at home for long-term analysis of gait and balance abnormalities. One area of particular concern involves the asymmetries in movement and balance that can accompany certain types of injuries and/or the associated devices used in the repair and rehabilitation process (e.g. the use of splints and casts) which can often increase chances of falls and additional injuries. This device has the capacity to monitor a patient during the rehabilitation process after injury or operation, increasing the patient’s access to healthcare while decreasing the number of visits to the patient’s clinician. The sensor device may thereby improve the quality of the patient’s care, particularly in rural areas where access to the clinician could be limited, while simultaneously decreasing the overall cost associated with the patient’s care. The device consists of nine interconnected accelerometer/ gyroscope/compass chips (9-DOF IMU, Adafruit, New York, NY). The sensors attach to and are used to determine the orientation and acceleration of the patient’s lower abdomen, C7 vertebra (lower neck), L1 vertebra (middle back), anterior side of each thigh and tibia, and dorsal side of each foot. In addition, pressure sensors are embedded in shoe inserts with one sensor (ESS301, Tekscan, Boston, MA) beneath the heel and three sensors (Interlink 402, Interlink Electronics, Westlake Village, CA) beneath the metatarsal bones of each foot. These sensors measure the distribution of the weight applied to each foot as well as stride duration. A small microntroller (Arduino Mega, Arduino, Ivrea, Italy) is used to collect data from these sensors in a CSV file. MATLAB is then used to analyze the data and output the hip, knee, ankle, and trunk angles projected on the sagittal plane. An open-source program Processing is then used to generate an animation of the patient’s gait. The accuracy of the sensors was validated through comparison to goniometric measurements (±2° error). The sensor device was also shown to have sufficient sensitivity to observe various gait abnormalities. Several patients used the sensor device, and the data collected from each represented the patient’s movements. Further, the sensors were found to have the ability to observe gait abnormalities caused by the addition of a small amount of weight (4.5 - 9.1 kg) to one side of the patient. The user-friendly interface and portability of the sensor device will help to construct a bridge between patients and their clinicians with fewer necessary inpatient visits.

Keywords: biomedical sensing, gait analysis, outpatient, rehabilitation

Procedia PDF Downloads 259
3728 3D Interferometric Imaging Using Compressive Hardware Technique

Authors: Mor Diama L. O., Matthieu Davy, Laurent Ferro-Famil

Abstract:

In this article, inverse synthetic aperture radar (ISAR) is combined with compressive imaging techniques in order to perform 3D interferometric imaging. Interferometric ISAR (InISAR) imaging relies on a two-dimensional antenna array providing diversities in the elevation and azimuth directions. However, the signals measured over several antennas must be acquired by coherent receivers resulting in costly and complex hardware. This paper proposes to use a chaotic cavity as a compressive device to encode the signals arising from several antennas into a single output port. These signals are then reconstructed by solving an inverse problem. Our approach is demonstrated experimentally with a 3-elements L-shape array connected to a metallic compressive enclosure. The interferometric phases estimated from a unique broadband signal are used to jointly estimate the target’s effective rotation rate and the height of the dominant scattering centers of our target. Our experimental results show that the use of the compressive device does not adversely affect the performance of our imaging process. This study opens new perspectives to reduce the hardware complexity of high-resolution ISAR systems.

Keywords: interferometric imaging, inverse synthetic aperture radar, compressive device, computational imaging

Procedia PDF Downloads 139
3727 A Small-Scale Survey on Risk Factors of Musculoskeletal Disorders in Workers of Logistics Companies in Cyprus and on the Early Adoption of Industrial Exoskeletons as Mitigation Measure

Authors: Kyriacos Clerides, Panagiotis Herodotou, Constantina Polycarpou, Evagoras Xydas

Abstract:

Background: Musculoskeletal disorders (MSDs) in the workplace is a very common problem in Europe which are caused by multiple risk factors. In recent years, wearable devices and exoskeletons for the workplace have been trying to address the various risk factors that are associated with strenuous tasks in the workplace. The logistics sector is a huge sector that includes warehousing, storage, and transportation. However, the task associated with logistics is not well-studied in terms of MSDs risk. This study was aimed at looking into the MSDs affecting workers of logistics companies. It compares the prevalence of MSDs among workers and evaluates multiple risk factors that contribute to the development of MSDs. Moreover, this study seeks to obtain user feedback on the adoption of exoskeletons in such a work environment. Materials and Methods: The study was conducted among workers in logistics companies in Nicosia, Cyprus, from July to September 2022. A set of standardized questionnaires was used for collecting different types of data. Results: A high proportion of logistics professionals reported MSDs in one or more other body regions, the lower back being the most commonly affected area. Working in the same position for long periods, working in awkward postures, and handling an excessive load, were found to be the most commonly reported job risk factor that contributed to the development of MSDs, in this study. A significant number of participants consider the back region as the most to be benefited from a wearable exoskeleton device. Half of the participants would like to have at least a 50% reduction in their daily effort. The most important characteristics for the adoption of exoskeleton devices were found to be how comfortable the device is and its weight. Conclusion: Lower back and posture were the highest risk factors among all logistics professionals assessed in this study. A larger scale study using quantitative analytical tools may give a more accurate estimate of MSDs, which would pave the way for making more precise recommendations to eliminate the risk factors and thereby prevent MSDs. A follow-up study using exoskeletons in the workplace should be done to assess whether they assist in MSD prevention.

Keywords: musculoskeletal disorders, occupational health, safety, occupational risk, logistic companies, workers, Cyprus, industrial exoskeletons, wearable devices

Procedia PDF Downloads 77
3726 Multi-Channel Charge-Coupled Device Sensors Real-Time Cell Growth Monitor System

Authors: Han-Wei Shih, Yao-Nan Wang, Ko-Tung Chang, Lung-Ming Fu

Abstract:

A multi-channel cell growth real-time monitor and evaluation system using charge-coupled device (CCD) sensors with 40X lens integrating a NI LabVIEW image processing program is proposed and demonstrated. The LED light source control of monitor system is utilizing 8051 microprocessor integrated with NI LabVIEW software. In this study, the same concentration RAW264.7 cells growth rate and morphology in four different culture conditions (DMEM, LPS, G1, G2) were demonstrated. The real-time cells growth image was captured and analyzed by NI Vision Assistant every 10 minutes in the incubator. The image binarization technique was applied for calculating cell doubling time and cell division index. The cells doubling time and cells division index of four group with DMEM, LPS, LPS+G1, LPS+G2 are 12.3 hr,10.8 hr,14.0 hr,15.2 hr and 74.20%, 78.63%, 69.53%, 66.49%. The image magnification of multi-channel CCDs cell real-time monitoring system is about 100X~200X which compares with the traditional microscope.

Keywords: charge-coupled device (CCD), RAW264.7, doubling time, division index

Procedia PDF Downloads 336
3725 Bionaut™: A Breakthrough Robotic Microdevice to Treat Non-Communicating Hydrocephalus in Both Adult and Pediatric Patients

Authors: Suehyun Cho, Darrell Harrington, Florent Cros, Olin Palmer, John Caputo, Michael Kardosh, Eran Oren, William Loudon, Alex Kiselyov, Michael Shpigelmacher

Abstract:

Bionaut Labs, LLC is developing a minimally invasive robotic microdevice designed to treat non-communicating hydrocephalus in both adult and pediatric patients. The device utilizes biocompatible microsurgical particles (Bionaut™) that are specifically designed to safely and reliably perform accurate fenestration(s) in the 3rd ventricle, aqueduct of Sylvius, and/or trapped intraventricular cysts of the brain in order to re-establish normal cerebrospinal fluid flow dynamics and thereby balance and/or normalize intra/intercompartmental pressure. The Bionaut™ is navigated to the target via CSF or brain tissue in a minimally invasive fashion with precise control using real-time imaging. Upon reaching the pre-defined anatomical target, the external driver allows for directing the specific microsurgical action defined to achieve the surgical goal. Notable features of the proposed protocol are i) Bionaut™ access to the intraventricular target follows a clinically validated endoscopy trajectory which may not be feasible via ‘traditional’ rigid endoscopy: ii) the treatment is microsurgical, there are no foreign materials left behind post-procedure; iii) Bionaut™ is an untethered device that is navigated through the subarachnoid and intraventricular compartments of the brain, following pre-designated non-linear trajectories as determined by the safest anatomical and physiological path; iv) Overall protocol involves minimally invasive delivery and post-operational retrieval of the surgical Bionaut™. The approach is expected to be suitable to treat pediatric patients 0-12 months old as well as adult patients with obstructive hydrocephalus who fail traditional shunts or are eligible for endoscopy. Current progress, including platform optimization, Bionaut™ control, and real-time imaging and in vivo safety studies of the Bionauts™ in large animals, specifically the spine and the brain of ovine models, will be discussed.

Keywords: Bionaut™, cerebrospinal fluid, CSF, fenestration, hydrocephalus, micro-robot, microsurgery

Procedia PDF Downloads 146
3724 Communication Experience and the Perception of Media Richness among Parents Working Overseas and Their Children Left-behind in the Philippines

Authors: Dennis Caasi

Abstract:

This study analyzed four knowledge-building elements of channel expansion theory namely: communication media, communication content, communication partner, and communication influence vis-à- vis media richness dimensions among parents working overseas and their left-behind children in the Philippines. Results reveal that both parents and children consumed four out of six mediated communications tested in this research, spent one to four days a week connecting, between 30 minutes to 3 hours per engagement, and media consumption is dependent on the message content and media literacy of parents. Family, academic, household, and health were the common communication topics and parents dictate which channel to use. All six medium tested received high ratings based on the media richness constructs.

Keywords: channel expansion theory, computer-mediated communication, media richness theory, overseas Filipino worker

Procedia PDF Downloads 316
3723 Primary Fallopian Tube Carcinoma: A Case Report

Authors: Mary Abigail T. Ty, Mary Jocelyn Yu-Laygo, Jocelyn Z. Mariano

Abstract:

This is a case of L.S.T., a 61 year old, G6P4 (3124) who presented with a one month history of intermittent, brownish, watery, non foul smelling vaginal discharge. There were no other accompanying symptoms. On rectovaginal examination, a palpable adnexal mass on the left was appreciated, with the lower border measuring 3 cm. The mass was non-tender, had irregular borders and solid areas. On transvaginal sonography, it revealed a left pelvic mass measuring 3 x 4 x 2 cm, with a Sassone score of 9. It had vascularization. The primary consideration was Ovarian Newgrowth, probably malignant in nature. CA-125 results were slightly elevated at 43.2 u/ml (NV: 0-35 u/ml). After intraoperative evaluation, the left fallopian tube was converted into a 9 x 4.5 x 3 cm bulbous cystic mass with solid areas. On cut section, the ampullary portion of the fallopian tube contained necrotic and friable looking tissues. Specimen was sent for frozen section and results revealed adenocarcinoma of the left fallopian tube. Patient subsequently underwent complete surgical staging with unremarkable post-operative course. The Surg Ico pathologic diagnosis was G6P4 (3124) Fallopian tube serous cystadenocarcinoma stage 1. The mean incidence of PFTC is 3.6 per million women yearly. This is associated with a generally low survival rate. The primary diagnosis is very difficult to establish because only 0–10% of patients suffering from PFTC are diagnosed pre-operatively. Symptoms play a very important role in the discovery of this disease, because there will be no presentation to the hospital without symptoms. The most common of which may be vaginal bleeding, abdominal pain, a palpable mass and ascites. A conglomerate of manifestations may be encountered, but not at all times. This is termed hydrops tubae profluens where there is presence of colicky pain with relief from intermittent passage of serosanguinous vaginal discharge. The significance of this report is to emphasize the rarity of the case and how the dilemma in the diagnosis is almost always present despite ancillary procedures.

Keywords: fallopian tube carcinoma, prognosis, rare, risk factors

Procedia PDF Downloads 299
3722 Synchronous Carcinoma Cervix with Vulvar Carcinoma in situ: A Case Report

Authors: Bhushan Bhalgat, Suresh Singh, Phanindra Swain, Kamal Kishore Lakhera

Abstract:

Carcinoma of cervix and carcinoma of vulva have been associated with common predisposing factors like human papillomavirus and smoking. Skip metastases and metachronous appearance of both these tumours have been reported. There is no case report showing synchronous appearance of these tumours in English literature. We herewith report a case report of a middle aged female patient who presented with per vaginal bleeding, and on examination, a cervical mass was palpable. Also, a proliferative growth was seen over her left vulva. Biopsy of both lesions came out to be squamous cell carcinoma and carcinoma in situ, respectively. A radical hysterectomy and bilateral pelvic and paraaortic lymph nodal dissection was performed along with left simple vulvectomy. This thereby underscores that any lesion over vulva appearing during or after treatment of cervical carcinoma should be biopsied to rule out vulvar carcinoma.

Keywords: carcinoma of cervix, carcinoma of vulva, synchronous tumours, gynecological oncology

Procedia PDF Downloads 146
3721 Atherosclerosis Prevalence Within Populations of the Southeastern United States

Authors: Samuel P. Prahlow, Anthony Sciuva, Katherine Bombly, Emily Wilson, Shiv Dhiman, Savita Arya

Abstract:

A prevalence cohort study of atherosclerotic lesions within cadavers was performed to better understand and characterize the prevalence of atherosclerosis among Georgia residents within body donors in the Philadelphia College of Osteopathic Medicine (PCOM) - Georgia body donor program. We procured specimens from cadavers used for medical students, physical therapy students, and biomedical science students cadaveric anatomical dissection at PCOM - South Georgia and PCOM - Georgia. Tissues were prepared using hematoxylin and eosin (H&E) stainas histological slides by Colquitt Regional Medical Center Laboratory Services. One section from each of the following arteries was taken after cadaveric dissection at the site of most calcification palpated grossly (if present): left anterior descending coronary artery, left internal carotid artery, abdominal aorta, splenic artery, and hepatic artery. All specimens were graded and categorized according to the American Heart Association’s Modified and Conventional Standards for Atherosclerotic Lesions using x4, x10, x40 microscopic magnification. Our study cohort included 22 cadavers, with 16 females and 6 males. The average age was 72.54, and the median age was 72, with a range of 52 to 90 years old. The cause of death determination listing vascular and/or cardiovascular causes was present on 6 of the 22 death certificates. 19 of 22 (86%) cadavers had at least a single artery grading > 5. Of the cadavers with at least a single artery graded at greater than 5, only 5 of 19 (26%) cadavers had a vascular or cardiovascular cause of death reported. Malignancy was listed as a cause of death on 7 (32%) death certificates. The average atherosclerosis grading of the common hepatic, splenic and left internal carotid arteries (2.15, 3.05, and 3.36 respectively) were lower than the left anterior descending artery and the abdominal aorta (5.16 and 5.86 respectively). This prevalence study characterizes atherosclerosis found in five medium and large systemic arteries within cadavers from the state of Georgia.

Keywords: pathology, atherosclerosis, histology, cardiovascular

Procedia PDF Downloads 195
3720 Parasitic Capacitance Modeling in Pulse Transformer Using FEA

Authors: D. Habibinia, M. R. Feyzi

Abstract:

Nowadays, specialized software is vastly used to verify the performance of an electric machine prototype by evaluating a model of the system. These models mainly consist of electrical parameters such as inductances and resistances. However, when the operating frequency of the device is above one kHz, the effect of parasitic capacitances grows significantly. In this paper, a software-based procedure is introduced to model these capacitances within the electromagnetic simulation of the device. The case study is a high-frequency high-voltage pulse transformer. The Finite Element Analysis (FEA) software with coupled field analysis is used in this method.

Keywords: finite element analysis, parasitic capacitance, pulse transformer, high frequency

Procedia PDF Downloads 500
3719 Performance, Scalability and Reliability Engineering: Shift Left and Shift Right Approach

Authors: Jyothirmayee Pola

Abstract:

Ideally, a test-driven development (TDD) or agile or any other process should be able to define and implement performance, scalability, and reliability (PSR) of the product with a higher quality of service (QOS) and should have the ability to fix any PSR issues with lesser cost before it hits the production. Most PSR test strategies for new product introduction (NPI) include assumptions about production load requirements but never accurate. NPE (New product Enhancement) include assumptions for new features that are being developed whilst workload distribution for older features can be derived by analyzing production transactions. This paper talks about how to shift left PSR towards design phase of release management process to get better QOS w.r.t PSR for any product under development. It also explains the ROI for future customer onboarding both for Service Oriented Architectures (SOA) and Microservices architectures and how to define PSR requirements.

Keywords: component PSR, performance engineering, performance tuning, reliability, return on investment, scalability, system PSR

Procedia PDF Downloads 46
3718 Performance Evaluation of Various Displaced Left Turn Intersection Designs

Authors: Hatem Abou-Senna, Essam Radwan

Abstract:

With increasing traffic and limited resources, accommodating left-turning traffic has been a challenge for traffic engineers as they seek balance between intersection capacity and safety; these are two conflicting goals in the operation of a signalized intersection that are mitigated through signal phasing techniques. Hence, to increase the left-turn capacity and reduce the delay at the intersections, the Florida Department of Transportation (FDOT) moves forward with a vision of optimizing intersection control using innovative intersection designs through the Transportation Systems Management & Operations (TSM&O) program. These alternative designs successfully eliminate the left-turn phase, which otherwise reduces the conventional intersection’s (CI) efficiency considerably, and divide the intersection into smaller networks that would operate in a one-way fashion. This study focused on the Crossover Displaced Left-turn intersections (XDL), also known as Continuous Flow Intersections (CFI). The XDL concept is best suited for intersections with moderate to high overall traffic volumes, especially those with very high or unbalanced left turn volumes. There is little guidance on determining whether partial XDL intersections are adequate to mitigate the overall intersection condition or full XDL is always required. The primary objective of this paper was to evaluate the overall intersection performance in the case of different partial XDL designs compared to a full XDL. The XDL alternative was investigated for 4 different scenarios; partial XDL on the east-west approaches, partial XDL on the north-south approaches, partial XDL on the north and east approaches and full XDL on all 4 approaches. Also, the impact of increasing volume on the intersection performance was considered by modeling the unbalanced volumes with 10% increment resulting in 5 different traffic scenarios. The study intersection, located in Orlando Florida, is experiencing recurring congestion in the PM peak hour and is operating near capacity with volume to a capacity ratio closer to 1.00 due to the presence of two heavy conflicting movements; southbound and westbound. The results showed that a partial EN XDL alternative proved to be effective and compared favorably to a full XDL alternative followed by the partial EW XDL alternative. The analysis also showed that Full, EW and EN XDL alternatives outperformed the NS XDL and the CI alternatives with respect to the throughput, delay and queue lengths. Significant throughput improvements were remarkable at the higher volume level with percent increase in capacity of 25%. The percent reduction in delay for the critical movements in the XDL scenarios compared to the CI scenario ranged from 30-45%. Similarly, queue lengths showed percent reduction in the XDL scenarios ranging from 25-40%. The analysis revealed how partial XDL design can improve the overall intersection performance at various demands, reduce the costs associated with full XDL and proved to outperform the conventional intersection. However, partial XDL serving low volumes or only one of the critical movements while other critical movements are operating near or above capacity do not provide significant benefits when compared to the conventional intersection.

Keywords: continuous flow intersections, crossover displaced left-turn, microscopic traffic simulation, transportation system management and operations, VISSIM simulation model

Procedia PDF Downloads 288