Search results for: dosimeter
12 Dynamic Fast Tracing and Smoothing Technique for Geiger-Muller Dosimeter
Authors: M. Ebrahimi Shohani, S. M. Taheri, S. M. Golgoun
Abstract:
Environmental radiation dosimeter is a kind of detector that measures the dose of the radiation area. Dosimeter registers the radiation and converts it to the dose according to the calibration parameters. The limit of a dose is different at each radiation area and this limit should be notified and reported to the user and health physics department. The stochastic nature of radiation is the reason for the fluctuation of any gamma detector dosimetry. In this research we investigated Geiger-Muller type of dosimeter and tried to improve the dose measurement. Geiger-Muller dosimeter is a counter that converts registered radiation to the dose. Therefore, for better data analysis, it is necessary to apply an algorithm to smooth statistical variations of registered radiation. We proposed a method to smooth these fluctuations much more and also proposed a dynamic way to trace rapid changes of radiations. Results show that our method is fast and reliable method in comparison the traditional method.
Keywords: Geiger-Muller, radiation detection, smoothing algorithms, dosimeter, dose calculation.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 46611 Directionally-Sensitive Personal Wearable Radiation Dosimeter
Authors: Hai Huu Le, Paul Junor, Moshi Geso, Graeme O’Keefe
Abstract:
In this paper, the authors propose a personal wearable directionally-sensitive radiation dosimeter using multiple semiconductor CdZnTe detectors. The proposed dosimeter not only measures the real-time dose rate but also provide the direction of the radioactive source. A linear relationship between radioactive source direction and the radiation intensity measured by each detectors is established and an equation to determine the source direction is derived by the authors. The efficiency and accuracy of the proposed dosimeter is verified by simulation using Geant4 package. Results have indicated that in a measurement duration of about 7 seconds, the proposed dosimeter was able to estimate the direction of a 10μCi 137/55Cs radioactive source to within 2 degrees.Keywords: Dose rate, Geant4 package, radiation detectors, radioactive source direction.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 119210 Effect of Gamma Radiation on Bromophenol Blue Dyed Films as Dosimeter
Authors: Priyanka R. Oberoi, Chandra B. Maurya, Prakash A. Mahanwar
Abstract:
Ionizing radiation can cause a drastic change in the physical and chemical properties of the material exposed. Numerous medical devices are sterilized by ionizing radiation. In the current research paper, an attempt was made to develop precise and inexpensive polymeric film dosimeter which can be used for controlling radiation dosage. Polymeric film containing (pH sensitive dye) indicator dye Bromophenol blue (BPB) was casted to check the effect of Gamma radiation on its optical and physical properties. The film was exposed to gamma radiation at 4 kGy/hr in the range of 0 to 300 kGy at an interval of 50 kGy. Release of vinyl acetate from an emulsion on high radiation reacts with the BPB fading the color of the film from blue to light blue and then finally colorless, indicating a change in pH from basic to acidic form. The change was characterized by using CIE l*a*b*, ultra-violet spectroscopy and FT-IR respectively.Keywords: Bromophenol blue, dosimeter, gamma radiation, polymer.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 27279 Development and Characterization of Normoxic Polyhydroxyethylacrylate (PHEA) Gel Dosimeter using Raman Spectroscopy
Authors: Aifa Afirah Rozlan, Mohamad Suhaimi Jaafar, Azhar Abdul Rahman
Abstract:
Raman spectroscopy are used to characterize the chemical changes in normoxic polyhydroxyethylacrylate gel dosimeter (PHEA) induced by radiation. Irradiations in the low dose region are performed and the polymerizations of PHEA gels are monitored by the observing the changes of Raman shift intensity of the carbon covalent bond of PHEA originated from both monomer and the cross-linker. The variation in peak intensities with absorbed dose was observed. As the dose increase, the peak intensities of covalent bond of carbon in the polymer gels decrease. This point out that the amount of absorbed dose affect the polymerization of polymer gels. As the absorbed dose increase, the polymerizations also increase. Results verify that PHEA gel dosimeters are sensitive even in lower dose region.Keywords: normoxic polymer gel, ascorbic acid, Ramanspectroscopy, radiation dosimetry.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 19428 Evaluating the Radiation Dose Involved in Interventional Radiology Procedures
Authors: Kholood Baron
Abstract:
Radiologic interventional studies use fluoroscopy imaging guidance to perform both diagnostic and therapeutic procedures. These could result in high radiation doses being delivered to the patients and also to the radiology team. This is due to the prolonged fluoroscopy time and the large number of images taken, even when dose-minimizing techniques and modern fluoroscopic tools are applied. Hence, these procedures are part of the everyday routine of interventional radiology doctors, assistant nurses, and radiographers. Thus, it is important to estimate the radiation exposure dose they received in order to give objective advice and reduce both patient and radiology team radiation exposure dose. The aim of this study was to find out the total radiation dose reaching the radiologist and the patient during an interventional procedure, and to determine the impact of certain parameters on the patient dose. The radiation dose was measured by TLD devices (Thermoluminescent Dosimeter; radiation dosimeter device). Physicians, patients, nurses, and radiographers wore TLDs during 12 interventional radiology procedures performed in two hospitals, Mubarak and Chest Hospital. This study highlights the need for interventional radiologists to be mindful of the radiation doses received by both patients and medical staff during interventional radiology procedures. The findings emphasize the impact of factors such as fluoroscopy duration and the number of images taken on the patient dose. By raising awareness and providing insights into optimizing techniques and protective measures, this research contributes to the overall goal of reducing radiation doses and ensuring the safety of patients and medical staff.
Keywords: Dosimetry, radiation dose, interventional radiology procedures, patient radiation dose.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 857 Psychological Impact of Radiation Versus Its Physiological Effects: Radiation Workers’ Perspective in Medical Centers
Authors: Muhammad Waqar, Touqir Ahmad Afridi, Quratulain Soomro
Abstract:
Radiation is a ghost causing unimaginable physical damage, but its harm is not inevitable. The panic created by previously reported worst-case scenarios i.e., Three Mile Island, Fukushima, Chernobyl, has adversely affected the attitude of radiation workers towards the profession. The psychological effect of radiation-related catastrophes creates an invisible barrier that reduces the efficiency of radiation workers. Careful handling and proper monitoring of radiation decreases the hazards of radiation and proves that the psychological impairment of radiation is myriad fold adverse than its physiological damage. Thermoluminescent Dosimeter (TLD) badges with unique identity numbers were provided to 36 radiation workers for a period of one year (2021). TLDs were read quarterly, and doses were recorded for every radiation worker. Annual doses were recorded and compared with national and international standards. Moreover, the period for which an individual worker is expected to reach one year limit of 20 mSv was also calculated. The highest radiation dose for the radiation worker in 2021 was found at 3.2 mSv, which was 16% of the permissible annual dose limit. The average occupational radiation doses ranged from 1.0 mSv to 3.20 mSv. 64% of the employees did not exceed the 10% of the annual limit, receiving less than 2 mSv. The least time for 20 mSv completion was found 6.25 years for the hot-lab technician. As a whole, the 20 mSv completion period ranged from 6.25 to 20 years. We concluded that the annual professional radiation doses were well within the permissible limits of Pakistan Nuclear Regulatory Authority (PNRA) and International Commission on Radiological Protection (ICRP). The fear of radiation is unnecessary and it creates reluctance towards performing their assigned duties and it is also not favorable for the institute. It must be abolished through education and training sessions.
Keywords: TLD, thermoluminescent dosimeter, psychological impact, radiation dose, annual dose limit, PNRA, ICRP, IAEA.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 4316 Characterization of an Extrapolation Chamber for Dosimetry of Low Energy X-Ray Beams
Authors: Fernanda M. Bastos, Teógenes A. da Silva
Abstract:
Extrapolation chambers were designed to be used as primary standard dosimeter for measuring absorbed dose in a medium in beta radiation and low energy x-rays. The International Organization for Standardization established series of reference x-radiation for calibrating and determining the energy dependence of dosimeters that are to be reproduced in metrology laboratories. Standardization of the low energy x-ray beams with tube potential lower than 30 kV may be affected by the instrument used for dosimetry. In this work, parameters of a 23392 model PTW extrapolation chamber were determined aiming its use in low energy x-ray beams as a reference instrument.Keywords: Extrapolation chamber, low energy x-rays, standardization, x-ray dosimetry.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 14595 Experimental Validation of Treatment Planning for Multiple Radiotherapy Fields by EDR2 Film Dosimeter
Authors: Vahid Fayaz , Asieh Tavakol
Abstract:
To investigate the applicability of the EDR-2 film for clinical radiation dosimetry, percentage depth-doses, profiles and distributions in open and dynamically wedged fields were measured using film and compared with data from a Treatment Planning system.The validity of the EDR2 film to measure dose in a plane parallel to the beam was tested by irradiating 10 cm×10 cm and 4 cm×4 cm fields from a Siemens, primus linac with a 6MV beam and a source-to-surface distance of 100 cm. The film was placed Horizontally between solid water phantom blocks and marked with pin holes at a depth of 10 cm from the incident beam surface. The film measurement results, in absolute dose, were compared with ion chamber measurements using a Welhoffer scanning water tank system and Treatment Planning system. Our results indicate a maximum underestimate of calculated dose of 8 % with Treatment Planning system.Keywords: 6MV Photon , EDR-2 film, Radiotherapy, TreatmentPlanning system
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 15164 Characterization of Three Photodetector Types for Computed Tomography Dosimetry
Authors: C. M. M. Paschoal, D. do N. Souza, L. A. P. Santos
Abstract:
In this study three commercial semiconductor devices were characterized in the laboratory for computed tomography dosimetry: one photodiode and two phototransistors. It was evaluated four responses to the irradiation: dose linearity, energy dependence, angular dependence and loss of sensitivity after X ray exposure. The results showed that the three devices have proportional response with the air kerma; the energy dependence displayed for each device suggests that some calibration factors would be applied for each one; the angular dependence showed a similar pattern among the three electronic components. In respect to the fourth parameter analyzed, one phototransistor has the highest sensitivity however it also showed the greatest loss of sensitivity with the accumulated dose. The photodiode was the device with the smaller sensitivity to radiation, on the other hand, the loss of sensitivity after irradiation is negligible. Since high accuracy is a desired feature for a dosimeter, the photodiode can be the most suitable of the three devices for dosimetry in tomography. The phototransistors can also be used for CT dosimetry, however it would be necessary a correction factor due to loss of sensitivity with accumulated dose.Keywords: Dosimetry, computed tomography, phototransistor, photodiode
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 22763 Optimizing Exposure Parameters in Digital Mammography: A Study in Morocco
Authors: Talbi Mohammed, Oustous Aziz, Ben Messaoud Mounir, Sebihi Rajaa, Khalis Mohammed
Abstract:
Background: Breast cancer is the leading cause of death for women around the world. Screening mammography is the reference examination, due to its sensitivity for detecting small lesions and micro-calcifications. Therefore, it is essential to ensure quality mammographic examinations with the most optimal dose. These conditions depend on the choice of exposure parameters. Clinically, practices must be evaluated in order to determine the most appropriate exposure parameters. Material and Methods: We performed our measurements on a mobile mammography unit (PLANMED Sofie-classic.) in Morocco. A solid dosimeter (AGMS Radcal) and a MTM 100 phantom allow to quantify the delivered dose and the image quality. For image quality assessment, scores are defined by the rate of visible inserts (MTM 100 phantom), obtained and compared for each acquisition. Results: The results show that the parameters of the mammography unit on which we have made our measurements can be improved in order to offer a better compromise between image quality and breast dose. The last one can be reduced up from 13.27% to 22.16%, while preserving comparable image quality.
Keywords: Mammography, image quality, breast dose.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 7852 Experimental and Analytical Dose Assessment of Patient's Family Members Treated with I-131
Authors: Marzieh Ebrahimi, Vahid Changizi, Mohammad Reza Kardan, Seyed Mahdi Hosseini Pooya, Parham Geramifar
Abstract:
Radiation exposure to the patient's family members is one of the major concerns during thyroid cancer radionuclide therapy. The aim of this study was to measure the total effective dose of the family members by means of thermoluminescence personal dosimeter, and compare with those calculated by analytical methods. Eighty-five adult family members of fifty-one patients volunteered to participate in this research study. Considering the minimum and maximum range of dose rate from 15 µsv/h to 120 µsv/h at patients' release time, the calculated mean and median dose values of family members were 0.45 mSv and 0.28 mSv, respectively. Moreover, almost all family members’ doses were measured to be less than the dose constraint of 5 mSv recommended by Basic Safety Standards. Considering the influence parameters such as patient dose rate and administrated activity, the total effective doses of family members were calculated by TEDE and NRC formulas and compared with those of experimental results. The results indicated that, it is fruitful to use the quantitative calculations for releasing patients treated with I-131 and correct estimation of patients' family doses.Keywords: Effective dose, thermoluminescence, I-131, Thyroid cancer.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 15101 Investigation of Threshold Voltage Shift in Gamma Irradiated N-Channel and P-Channel MOS Transistors of CD4007
Authors: S. Boorboor, S. A. H. Feghhi, H. Jafari
Abstract:
The ionizing radiations cause different kinds of damages in electronic components. MOSFETs, most common transistors in today’s digital and analog circuits, are severely sensitive to TID damage. In this work, the threshold voltage shift of CD4007 device, which is an integrated circuit including P-channel and N-channel MOS transistors, was investigated for low dose gamma irradiation under different gate bias voltages. We used linear extrapolation method to extract threshold voltage from ID-VG characteristic curve. The results showed that the threshold voltage shift was approximately 27.5 mV/Gy for N-channel and 3.5 mV/Gy for P-channel transistors at the gate bias of |9 V| after irradiation by Co-60 gamma ray source. Although the sensitivity of the devices under test were strongly dependent to biasing condition and transistor type, the threshold voltage shifted linearly versus accumulated dose in all cases. The overall results show that the application of CD4007 as an electronic buffer in a radiation therapy system is limited by TID damage. However, this integrated circuit can be used as a cheap and sensitive radiation dosimeter for accumulated dose measurement in radiation therapy systems.
Keywords: Threshold voltage shift, MOS transistor, linear extrapolation, gamma irradiation.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1380