Search results for: radiographic measurements
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2830

Search results for: radiographic measurements

2800 Relative Depth Dose Profile and Peak Scatter Factors Measurement for Co-60 Teletherapy Machine Using Chemical Dosimetry

Authors: O. Moussous, T. Medjadj

Abstract:

The suitability of a Fricke dosimeter for the measurement of a relative depth dose profile and the peak scatter factors was studied. The measurements were carried out in the secondary standard dosimetry laboratory at CRNA Algiers using a collimated 60Co gamma source teletherapy machine. The measurements were performed for different field sizes at the phantom front face, at a fixed source-to-phantom distance of 80 cm. The dose measurements were performed by first placing the dosimeters free-in-air at the distance-source-detector (DSD) of 80.5 cm from the source. Additional measurements were made with the phantom in place. The water phantom type Med-Tec 40x40x40 cm for vertical beam was used in this work as scattering martial. The phantom was placed on the irradiation bench of the cobalt unit at the SSD of 80 cm from the beam focus and the centre of the field coincided with the geometric centre of the dosimeters placed at the depth in water of 5 mm Relative depth dose profile and Peak scatter factors measurements were carried out using our Fricke system. This was intercompared with similar measurements by ionization chamber under identical conditions. There is a good agreement between the relative percentage depth–dose profiles and the PSF values measured by both systems using a water phantom.

Keywords: Fricke dosimeter, depth–dose profiles, peak scatter factors, DSD

Procedia PDF Downloads 228
2799 Validation of Visibility Data from Road Weather Information Systems by Comparing Three Data Resources: Case Study in Ohio

Authors: Fan Ye

Abstract:

Adverse weather conditions, particularly those with low visibility, are critical to the driving tasks. However, the direct relationship between visibility distances and traffic flow/roadway safety is uncertain due to the limitation of visibility data availability. The recent growth of deployment of Road Weather Information Systems (RWIS) makes segment-specific visibility information available which can be integrated with other Intelligent Transportation System, such as automated warning system and variable speed limit, to improve mobility and safety. Before applying the RWIS visibility measurements in traffic study and operations, it is critical to validate the data. Therefore, an attempt was made in the paper to examine the validity and viability of RWIS visibility data by comparing visibility measurements among RWIS, airport weather stations, and weather information recorded by police in crash reports, based on Ohio data. The results indicated that RWIS visibility measurements were significantly different from airport visibility data in Ohio, but no conclusion regarding the reliability of RWIS visibility could be drawn in the consideration of no verified ground truth in the comparisons. It was suggested that more objective methods are needed to validate the RWIS visibility measurements, such as continuous in-field measurements associated with various weather events using calibrated visibility sensors.

Keywords: RWIS, visibility distance, low visibility, adverse weather

Procedia PDF Downloads 229
2798 Measurement of Nasal Septal Cartilage in Adult Filipinos Using Computed Tomography

Authors: Miguel Limbert Ramos, Joseph Amado Galvez

Abstract:

Background: The nasal septal cartilage is an autologous graft that is widely used in different otolaryngologic procedures of the different subspecialties, such as in septorhinoplasty and ear rehabilitation procedures. The cartilage can be easily accessed and harvested to be utilized for such procedures. However, the dimension of the nasal septal cartilage differs, corresponding to race, gender, and age. Measurements can be done via direct measurement of harvested septal cartilage in cadavers or utilizing radiographic imaging studies giving baseline measurement of the nasal septal cartilage distinct to every race. A preliminary baseline measurement of the dimensions of Filipino nasal septal cartilage was previously established by measuring harvested nasal septal cartilage in Filipino Malay cadavers. This study intends to reinforce this baseline measurement by utilizing computed tomography (CT) scans of adult Filipinos in a tertiary government hospital in the City of Manila, Philippines, which will cover a larger sampling population. Methods: The unit of observation and analysis will be the computed tomography (CT) scans of patients ≥ 18years old who underwent cranial, facial, orbital, paranasal sinus, and temporal bone studies for the year 2019. The measurements will be done in a generated best midsagittal image (155 subjects) which is a view through the midline of the cerebrum that is simultaneously viewed with its coronal and axial views for proper orientation. The view should reveal important structures that will be used to plot the anatomic boundaries, which will be measured by a DICOM image viewing software (RadiAnt). The measured area of nasal septal cartilage will be compared by gender and age. Results: The total area of the nasal septal cartilage is larger in males compared to females, with a mean value of 6.52 cm² and 5.71 cm², respectively. The harvestable nasal septal cartilage area is also larger in males with a mean value of 3.57 cm² compared to females with only a measured mean value of 3.13 cm². The total and harvestable area of the nasal septal cartilage is largest in the 18-30 year-old age group with a mean value of 6.47 cm² and 3.60 cm² respectively and tends to decrease with the advancement of age, which can be attributed to continuous ossification changes. Conclusion: The best time to perform septorhinoplasty and other otolaryngologic procedures which utilize the nasal septal cartilage as graft material is during post-pubertal age, hence surgeries should be avoided or delayed to allow growth and maturation of the cartilage. A computed tomography scan is a cost-effective and non-invasive tool that can provide information on septal cartilage areas prior to these procedures.

Keywords: autologous graft, computed tomography, nasal septal cartilage, septorhinoplasty

Procedia PDF Downloads 123
2797 Macular Ganglion Cell Inner Plexiform Layer Thinning

Authors: Hye-Young Shin, Chan Kee Park

Abstract:

Background: To compare the thinning patterns of the ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (pRNFL) as measured using Cirrus high-definition optical coherence tomography (HD-OCT) in patients with visual field (VF) defects that respect the vertical meridian. Methods: Twenty eyes of eleven patients with VF defects that respect the vertical meridian were enrolled retrospectively. The thicknesses of the macular GCIPL and pRNFL were measured using Cirrus HD-OCT. The 5% and 1% thinning area index (TAI) was calculated as the proportion of abnormally thin sectors at the 5% and 1% probability level within the area corresponding to the affected VF. The 5% and 1% TAI were compared between the GCIPL and pRNFL measurements. Results: The color-coded GCIPL deviation map showed a characteristic vertical thinning pattern of the GCIPL, which is also seen in the VF of patients with brain lesions. The 5% and 1% TAI were significantly higher in the GCIPL measurements than in the pRNFL measurements (all P < 0.01). Conclusions: Macular GCIPL analysis clearly visualized a characteristic topographic pattern of retinal ganglion cell (RGC) loss in patients with VF defects that respect the vertical meridian, unlike pRNFL measurements. Macular GCIPL measurements provide more valuable information than pRNFL measurements for detecting the loss of RGCs in patients with retrograde degeneration of the optic nerve fibers.

Keywords: brain lesion, macular ganglion cell, inner plexiform layer, spectral-domain optical coherence tomography

Procedia PDF Downloads 313
2796 Association of Musculoskeletal and Radiological Features with Clinical and Serological Findings in Systemic Sclerosis: A Single-Centre Registry Study

Authors: Rezvan Hosseinian

Abstract:

Aim: Systemic sclerosis (SSc) is a chronic connective tissue disease with the clinical hallmark of skin thickening and tethering. The correlation of musculoskeletal features with other parameters should be considered in SSc patients. Methods: We reviewed the records of all patients who had more than one visit and standard anteroposterior radiography of hand. We used univariate analysis, and factors with p<0.05 were included in logistic regression to find out dependent factors. Results: Overall, 180 SSc patients were enrolled in our study, 161 (89.4%) of whom were women. The median age (IQR) was 47.0 years (16), and 52% had a diffuse subtype of the disease. In multivariate analysis, tendon friction rubs (TFRs) were associated with the presence of calcinosis, muscle tenderness, and flexion contracture (FC) on physical examination (p<0.05). Arthritis showed no differences in the two subtypes of the disease (p=0.98), and in multivariate analysis, there were no correlations between radiographic arthritis and serological and clinical features. The radiographic results indicated that disease duration correlated with joint erosion, acro-osteolysis, resorption of the distal ulna, calcinosis and radiologic FC (p< 0.05). Acro-osteolysis was more frequent in the dcSSc subtype, TFRs, and anti-TOPO I antibody. Radiologic FC showed an association with skin score, calcinosis and haematocrit <30% (p<0.05). Joint flexion on radiography was associated with disease duration, modified Rodnan skin score, calcinosis, and low hematocrit (P<0.01). Conclusion: Disease duration was a main dependent factor for developing joint erosion, acro-osteolysis, bone resorption, calcinosis, and flexion contracture on hand radiography. Acro-osteolysis presented in the severe form of the disease. Acro-osteolysis was the only dependent variable associated with bone demineralization.

Keywords: disease subsets, hand radiography, joint erosion, sclerosis

Procedia PDF Downloads 54
2795 Association of Musculoskeletal and Radiological Features with Clinical and Serological Findings in Systemic Sclerosis: A Single-Centre Registry Study

Authors: Nasrin Azarbani

Abstract:

Aim: Systemic sclerosis (SSc) is a chronic connective tissue disease with the clinical hallmark of skin thickening and tethering. Correlation of musculoskeletal features with other parameters should be considered in SSc patients. Methods: We reviewed the records of all patients who had more than one visit and standard anteroposterior radiography of hand. We used univariate analysis, and factors with p<0.05 were included in logistic regression to find out dependent factors. Results: Overall, 180 SSc patients were enrolled in our study, 161 (89.4%) of whom were women. Median age (IQR) was 47.0 years (16), and 52% had diffuse subtype of the disease. In multivariate analysis, tendon friction rubs (TFRs) was associated with the presence of calcinosis, muscle tenderness, and flexion contracture (FC) on physical examination (p<0.05). Arthritis showed no differences in the two subtypes of the disease (p=0.98), and in multivariate analysis, there were no correlations between radiographic arthritis and serological and clinical features. The radiographic results indicated that disease duration correlated with joint erosion, acro-osteolysis, resorption of distal ulna, calcinosis and radiologic FC (p< 0.05). Acro-osteolysis was more frequent in the dcSSc subtype, TFRs, and anti-TOPO I antibody. Radiologic FC showed an association with skin score, calcinosis and haematocrit <30% (p<0.05). Joint flexion on radiography was associated with disease duration, modified Rodnan skin score, calcinosis, and low haematocrit (P<0.01). Conclusion: Disease duration was a main dependent factor for developing joint erosion, acro-osteolysis, bone resorption, calcinosis, and flexion contracture on hand radiography. Acro-osteolysis presented in the severe form of the disease. Acro-osteolysis was the only dependent variable associated with bone demineralization.

Keywords: sclerosis, disease subsets, joint erosion, musculoskeletal

Procedia PDF Downloads 41
2794 Validating Thermal Performance of Existing Wall Assemblies Using In-Situ Measurements

Authors: Shibei Huang

Abstract:

In deep energy retrofits, the thermal performance of existing building envelopes is often difficult to determine with a high level of accuracy. For older buildings, the records of existing assemblies are often incomplete or inaccurate. To obtain greater baseline performance accuracy for energy models, in-field measurement tools can be used to obtain data on the thermal performance of the existing assemblies. For a known assembly, these field measurements assist in validating the U-factor estimates. If the field-measured U-factor consistently varies from the calculated prediction, those measurements prompt further study. For an unknown assembly, successful field measurements can provide approximate U-factor evaluation, validate assumptions, or identify anomalies requiring further investigation. Using case studies, this presentation will focus on the non-destructive methods utilizing a set of various field tools to validate the baseline U-factors for a range of existing buildings with various wall assemblies. The lessons learned cover what can be achieved, the limitations of these approaches and tools, and ideas for improving the validity of measurements. Key factors include the weather conditions, the interior conditions, the thermal mass of the measured assemblies, and the thermal profiles of the assemblies in question.

Keywords: existing building, sensor, thermal analysis, retrofit

Procedia PDF Downloads 27
2793 Correlation Results Based on Magnetic Susceptibility Measurements by in-situ and Ex-Situ Measurements as Indicators of Environmental Changes Due to the Fertilizer Industry

Authors: Nurin Amalina Widityani, Adinda Syifa Azhari, Twin Aji Kusumagiani, Eleonora Agustine

Abstract:

Fertilizer industry activities contribute to environmental changes. Changes to the environment became one of a few problems in this era of globalization. Parameters that can be seen as criteria to identify changes in the environment can be seen from the aspects of physics, chemistry, and biology. One aspect that can be assessed quickly and efficiently to describe environmental change is the aspect of physics, one of which is the value of magnetic susceptibility (χ). The rock magnetism method can be used as a proxy indicator of environmental changes, seen from the value of magnetic susceptibility. The rock magnetism method is based on magnetic susceptibility studies to measure and classify the degree of pollutant elements that cause changes in the environment. This research was conducted in the area around the fertilizer plant, with five coring points on each track, each coring point a depth of 15 cm. Magnetic susceptibility measurements were performed by in-situ and ex-situ. In-situ measurements were carried out directly by using the SM30 tool by putting the tools on the soil surface at each measurement point and by that obtaining the value of the magnetic susceptibility. Meanwhile, ex-situ measurements are performed in the laboratory by using the Bartington MS2B tool’s susceptibility, which is done on a coring sample which is taken every 5 cm. In-situ measurement shows results that the value of magnetic susceptibility at the surface varies, with the lowest score on the second and fifth points with the -0.81 value and the highest value at the third point, with the score of 0,345. Ex-situ measurements can find out the variations of magnetic susceptibility values at each depth point of coring. At a depth of 0-5 cm, the value of the highest XLF = 494.8 (x10-8m³/kg) is at the third point, while the value of the lowest XLF = 187.1 (x10-8m³/kg) at first. At a depth of 6-10 cm, the highest value of the XLF was at the second point, which was 832.7 (x10-8m³/kg) while the lowest XLF is at the first point, at 211 (x10-8m³/kg). At a depth of 11-15 cm, the XLF’s highest value = 857.7 (x10-8m³/kg) is at the second point, whereas the value of the lowest XLF = 83.3 (x10-8m³/kg) is at the fifth point. Based on the in situ and exsit measurements, it can be seen that the highest magnetic susceptibility values from the surface samples are at the third point.

Keywords: magnetic susceptibility, fertilizer plant, Bartington MS2B, SM30

Procedia PDF Downloads 315
2792 A Modified Open Posterior Approach for the Fixation of Posterior Cruciate Ligament Tibial Avulsion Fractures

Authors: Babak Mirzashahi, Arvin Najafi, Pejman Mansouri, Mahmoud Farzan

Abstract:

Background: The most effective treatment of posterior cruciate ligament (PCL) tears and the consequence of untreated PCL injuries remain controversial. Objectives: The aim of this study is to assess outcomes of fixation of tibial posterior cruciate ligament (PCL) avulsion fractures via a modified technique. Patients and Methods: From January, 2009 to March, 2012, there were 45 cases of PCL tibial avulsion fractures that were referred to our hospital and were managed through a modified open posterior approach. Fixation of Tibial PCL avulsion fractures were fixed by means of a lag screw and washer placed through our modified open posterior approach. Range of motion was begun on the first postoperative day. Clinical stability, range of motion, gastrocnemius muscle strength, radiographic investigation, and patient’s overall quality of life was analyzed at final follow up visit. Results: The average of overall musculoskeletal functional evaluation scores was 15 (range 3–35). All patients achieved union of their fracture and had clinically stable knees at the latest follow-up. The mean preoperative Lysholm score for 15 knees was 62 ± 8 (range, 50-75); the mean postoperative Lysholm score was 92± 7 (range, 75-101). A significant difference in Lysholm scores between preoperative and final follow-up evaluations was found (P < .05). At first-year follow-up, 42 (93%) patients revealed a difference of less than 10 mm in thigh circumference between their injured and healthy knees. Conclusions: The management of displaced large PCL avulsion fractures with placement of a cancellous lag screw with washer by means of the modified open posterior approach leads to satisfactory clinical, radiographic, and functional results and reduces the operation time and less blood loss. Level of evidence: IV.

Keywords: posterior cruciate ligament, tibial fracture, lysholm knee score, patient outcome assessment

Procedia PDF Downloads 279
2791 The Bone Remodeling of Mandible in Bruxers

Authors: Eni Rahmi, Rasmi Rikmasari, Taufik Soemarsongko

Abstract:

Background: One of the bad habits that requires a treatment and viewed as a risk factor of the temporomandibular disorder is bruxism. Bruxism defined as an awake and/or asleep parafunctional activities include grinding, gnashing, bracing or clenching of the teeth. In particular circumstances such as an increased frequency of episode, duration and the intensity of masseter contractions, caused phenomenon with pathological consequences, i.e., mandibular remodeling. The remodeling in mandibular angle was associated with the masseter and pterygoid medial muscles attachment which in its insertion area. The aim of this study was to compare the mandibular remodeling between bruxers and non-bruxers with ramus height, gonial angle and bigonial width as parameters, and to identify correlation among those parameters in bruxers, using panoramic radiographic. Methods: This study was conducted on 35 bruxers (10 phasic bruxism patients, 6 tonic bruxism patients, and 19 mixed bruxism patients) and 20 non-bruxers as control group. The data were obtained by using questionary, clinical examination, and radiographic measurement. Panoramic radiograph measurement was done using soft CBCT EPX Impla (E-Woo Korea). The data was analyzed by using Paired T-Test to see differences between parameters in both group and Pearson Correlation Test to evaluate correlation among parameters. Result: There was significant differences between bruxers and non-bruxers in ramus heights (p=0,04), bigonial widths (p=0,001), and gonial angles(p=0,015). The bruxers showed increased ramus heights and bigonial widths, in other hand, the gonial angles decreased. This study also found that there was highly correlation among ramus height, gonial angles, and bigonial widths. Conclusion: the bone remodeling occurred on inferior and posterior border of mandibular angle in bruxism patient, indicated by the form and size differences between bruxers (phasic bruxism, tonic bruxism, and mixed bruxism) with non-bruxers, which shown by panoramic radiograph.

Keywords: bruxism, ramus height, gonial angle, bigonial width

Procedia PDF Downloads 268
2790 Review of Dielectric Permittivity Measurement Techniques

Authors: Ahmad H. Abdelgwad, Galal E. Nadim, Tarek M. Said, Amr M. Gody

Abstract:

The prime objective of this manuscript is to provide intensive review of the techniques used for permittivity measurements. The measurement techniques, relevant for any desired application, rely on the nature of the measured dielectric material, both electrically and physically, the degree of accuracy required, and the frequency of interest. Regardless of the way that distinctive sorts of instruments can be utilized, measuring devices that provide reliable determinations of the required electrical properties including the obscure material in the frequency range of interest can be considered. The challenge in making precise dielectric property or permittivity measurements is in designing of the material specimen holder for those measurements (RF and MW frequency ranges) and adequately modeling the circuit for reliable computation of the permittivity from the electrical measurements. If the RF circuit parameters such as the impedance or admittance are estimated appropriately at a certain frequency, the material’s permittivity at this frequency can be estimated by the equations which relate the way in which the dielectric properties of the material affect on the parameters of the circuit.

Keywords: dielectric permittivity, free space measurement, waveguide techniques, coaxial probe, cavity resonator

Procedia PDF Downloads 345
2789 Assessment of the Occupancy’s Effect on Speech Intelligibility in Al-Madinah Holy Mosque

Authors: Wasim Orfali, Hesham Tolba

Abstract:

This research investigates the acoustical characteristics of Al-Madinah Holy Mosque. Extensive field measurements were conducted in different locations of Al-Madinah Holy Mosque to characterize its acoustic characteristics. The acoustical characteristics are usually evaluated by the use of objective parameters in unoccupied rooms due to practical considerations. However, under normal conditions, the room occupancy can vary such characteristics due to the effect of the additional sound absorption present in the room or by the change in signal-to-noise ratio. Based on the acoustic measurements carried out in Al-Madinah Holy Mosque with and without occupancy, and the analysis of such measurements, the existence of acoustical deficiencies has been confirmed.

Keywords: Al-Madinah Holy Mosque, mosque acoustics, speech intelligibility, worship sound

Procedia PDF Downloads 146
2788 Calibration Methods of Direct and Indirect Reading Pressure Sensor and Uncertainty Determination

Authors: Sinem O. Aktan, Musa Y. Akkurt

Abstract:

Experimental pressure calibration methods can be classified into three areas: (1) measurements in liquid or gas systems, (2) measurements in static-solid media systems, and (3) measurements in dynamic shock systems. Fluid (liquid and gas) systems high accuracies can be obtainable and commonly used for the calibration method of a pressure sensor. Pressure calibrations can be performed for metrological traceability in two ways, which are on-site (field) and in the laboratory. Laboratory and on-site calibration procedures and the requirements of the DKD-R-6-1 and Euramet cg-17 guidelines will also be addressed. In this study, calibration methods of direct and indirect reading pressure sensor and measurement uncertainty contributions will be explained.

Keywords: pressure metrology, pressure calibration, dead-weight tester, pressure uncertainty

Procedia PDF Downloads 119
2787 Cup-Cage Construct for Treatment of Severe Acetabular Bone Loss in Revision Total Hip Arthroplasty: Midterm Clinical and Radiographic Outcomes

Authors: Faran Chaudhry, Anser Daud, Doris Braunstein, Oleg Safir, Allan Gross, Paul Kuzyk

Abstract:

Background: Acetabular reconstruction in the context of massive acetabular bone loss is challenging. In rare scenarios where the extent of bone loss precludes shell placement (cup-cage), reconstruction at our center consisted of a cage combined with highly porous metal augments. This study evaluates survivorship, complications, and functional outcomes using this technique. Methods: A total of 131 cup-cage implants (129 patients) were included in our retrospective review of revisions of total hip arthroplasty from January 2003 to January 2022. Among these cases, 100/131 (76.3%) were women, the mean age at surgery time was 68.7 years (range, 29.0 to 92.0; SD, 12.4), and the mean follow-up was 7.7 years (range, 0.02 to 20.3; SD, 5.1). Kaplan-Meier survivorship analysis was conducted with failure defined as revision surgery and/or failure of the cup-cage reconstruction. Results: A total of 30 implants (23%) reached the study endpoint involving all-cause revision. Overall survivorship was 74.8% at 10 years and 69.8% at 15 years. Reasons for revision included infection 12/131 (9.1%), dislocation 10/131 (7.6%), aseptic loosening of cup and/or cage 5/131 (3.8%), and aseptic loosening of the femoral stem 2/131 (1.5%). The mean LLD improved from 12.2 ± 15.9 mm to 3.9 ± 11.8 (p<0.05). The horizontal and vertical hip centres on plain film radiographs were significantly improved (p<0.05). Functionally, there was a decrease in the number of patients requiring the use of gait aids, with fewer patients (34, 25.9%) using a cane, walker, or wheelchair post-operatively compared to pre-operatively (58, 44%). There was a significant increase in the number of independent ambulators from 24 to 47 (36%). Conclusion: The cup-cage construct is a reliable treatment option for the treatment of various acetabular defects. There are favourable survivorship, clinical and radiographic outcomes, with a satisfactory complication rate.

Keywords: revision total hip arthroplasty, acetabular defect, pelvic discontinuity, trabecular metal augment, cup-cage

Procedia PDF Downloads 32
2786 Comparison of Intraocular Pressure Measurement Prior and Following Full Intracorneal Ring Implantation in Patient with Keratoconus by Three Different Instruments

Authors: Seyed Aliasghar Mosavi, Mostafa Naderi, Khosrow Jadidi, Amir Hashem Mohammadi

Abstract:

To study the measurement of intraocular pressure (IOP) before and after implantation of intrastromal corneal ring (MyoRing) in patients with keratoconus. Setting: Baqiyatallah University of Medical Sciences, Tehran, Iran. Methods: We compared the IOP of 13 eyes which underwent MyoRing implantation prior and six months post operation using Goldman applanation (as gold standard), Icare, and Corvis ST (uncorrected, corrected and corrected with cornea biomechanics). Results: The resulting intraocular pressure measurements prior to surgery, Icare, Corvis (corrected with cornea biomechanics) overestimated the IOP, however measurements by Corvis uncorrected underestimate the IOP. The resulting intraocular pressure measurements after surgery, Icare, Corvis (corrected with cornea biomechanics) overestimated the IOP but measurements by Corvis uncorrected underestimate the IOP. Conclusion: Consistent intraocular pressure measurements on eyes with Myoring in keratoconus can be obtained with the Goldman applanation tonometer as the gold standard measurement. We were not able to obtain consistent results when we measured the IOP by Icare and Corvis prior and after surgery.

Keywords: intraocular pressure, MyoRing, Keratoconus, Goldmann applanation, Icare, Corvis ST

Procedia PDF Downloads 218
2785 Experimental Partial Discharge Localization for Internal Short Circuits of Transformers Windings

Authors: Jalal M. Abdallah

Abstract:

This paper presents experimental studies carried out on a three phase transformer to investigate and develop the transformer models, which help in testing procedures, describing and evaluating the transformer dielectric conditions process and methods such as: the partial discharge (PD) localization in windings. The measurements are based on the transfer function methods in transformer windings by frequency response analysis (FRA). Numbers of tests conditions were applied to obtain the sensitivity frequency responses of a transformer for different type of faults simulated in a particular phase. The frequency responses were analyzed for the sensitivity of different test conditions to detect and identify the starting of small faults, which are sources of PD. In more detail, the aim is to explain applicability and sensitivity of advanced PD measurements for small short circuits and its localization. The experimental results presented in the paper will help in understanding the sensitivity of FRA measurements in detecting various types of internal winding short circuits in the transformer.

Keywords: frequency response analysis (FRA), measurements, transfer function, transformer

Procedia PDF Downloads 253
2784 Percentage Change in the Selected Skinfold Measurements of Male Students of University of Delhi Due to Progressive and Constant Load of Physical Training

Authors: Seema Kaushik

Abstract:

Skinfold measurements provide considerably meaningful and consistent information about subcutaneous fat and its distribution. Physical activities in the form of conditioning and/or training leads to various structural, functional and mechanical changes and numerous training programmes exist for the improvement of physical fitness, however, most of the studies are conducted on foreign soil with foreign population as sample, which may/may not be applicable to the Indian conditions. Moreover, there is not even a single training/ conditioning programme that caters to the need of male students of University of Delhi with regard to various skinfold thickness measurements. Hence, the present study aimed at studying the effect of progressive and constant load training on selected skinfold measurements of male students of University of Delhi in form of percentage change. The sample size for the study was 90 having three groups of male; 30 samples in each group (mean age = 20.04±0.49 years). The variables included triceps, sub-scapular, supra-iliac and calf skinfolds. The experimental design adopted for the study was multi-group repeated measure design. Three different groups were measured four times repeatedly at an interval of 6 weeks, on completion of each of the three meso-cycles. Standard landmarks and protocols were followed to measure the selected variables. Mean, standard deviation and percentage were computed to analyze the data statistically. The study concluded that both the progressive and constant load of physical training bring changes in the skinfold thickness measurements of male students of University of Delhi.

Keywords: constant load, progressive load, physical training, skinfold measurements

Procedia PDF Downloads 302
2783 Eight-Week Exercise for Women: Impact on Anomalies in Width Depth and Environmental Dimension

Authors: Yalcin Kaya, Fatma Arslan, Ahmet Selim Kaya

Abstract:

This study aimed to determine the undesirable hypertrophic anomalies in the body of females and to investigate how they can be affected by the exercise program according to the applied 8 week individual conditions. The research was carried out on 35 women who did not have any regular previous sports practice and had an approximate age of 30 ± 5.0 at the gymnasium because of their asymmetric structure and weight gain of the body. Measurements of width, depth, and periphery were taken from the participants' body, and the exercise protocol was applied for 8 weeks according to the individual measurements in accordance with the obtained measurements. After 8 weeks, the same measurements were applied again. Measurements were made by using ruler and paper tape. The findings were evaluated and differences were analyzed by paired sample t test. According to the findings obtained, ulnae distal proiecturas width averages were 44.77 ± 3.65 and 43.52 ± 3.47 pre- and post-exercise respectively. Bithorachanteric width averages were 29.3 ± 3.12 before exercise and 26.67 ± 3.27 after exercise. Average abdominal widths were observed as 18.64 ± 4.14 (before exercise) and 18.01 ± 6.27 (after exercise). The distances between the malleolus were measured as 16.98 ± 1.62 (before exercise) and 16.70 ± 1.64 (after exercise). The results were statistically significant (p < 0.05). The mean of pre-exercise Externus abdominis circumference was 93.97 ± 8.91, and the mean of post-exercise mean was 90.82 ± 8.24. The results are statistically significant (p < 0.05). In conclusion, findings of the study show that inactivity, daily uncontrolled activities or erroneous postural postures, malnutrition cause some anomalies in the human body. However, with consciously standardized and regular exercises, these abnormalities are reduced by an eight-week exercise protocol in parallel with the expulsion of excess kilos and can be removed when working much longer and fitter, it is proposed to be healthier and more beautiful in appearance.

Keywords: women, body, circumference-width and depth measurements, hypertrophy, exercise

Procedia PDF Downloads 356
2782 Ankle Fracture Management: A Unique Cross Departmental Quality Improvement Project

Authors: Langhit Kurar, Loren Charles

Abstract:

Introduction: In light of recent BOAST 12 (August 2016) published guidance on management of ankle fractures, the project aimed to highlight key discrepancies throughout the care trajectory from admission to point of discharge at a district general hospital. Wide breadth of data covering three key domains: accident and emergency, radiology, and orthopaedic surgery were subsequently stratified and recommendations on note documentation, and outpatient follow up were made. Methods: A retrospective twelve month audit was conducted reviewing results of ankle fracture management in 37 patients. Inclusion criterion involved all patients seen at Darent Valley Hospital (DVH) emergency department with radiographic evidence of an ankle fracture. Exclusion criterion involved all patients managed solely by nursing staff or having sustained purely ligamentous injury. Medical notes, including discharge summaries and the PACS online radiographic tool were used for data extraction. Results: Cross-examination of the A & E domain revealed limited awareness of the BOAST 12 recent publication including requirements to document skin integrity and neurovascular assessment. This had direct implications as this would have changed the surgical plan for acutely compromised patients. The majority of results obtained from the radiographic domain were satisfactory with appropriate X-rays taken in over 95% of cases. However, due to time pressures within A & E, patients were often left without a post manipulation XRAY in a backslab. Poorly reduced fractures were subsequently left for a long period resulting in swollen ankles and a time-dependent lag to surgical intervention. This had knocked on implications for prolonged inpatient stay resulting in hospital-acquired co-morbidity including pressure sores. Discussion: The audit has highlighted several areas of improvement throughout the disease trajectory from review in the emergency department to follow up as an outpatient. This has prompted the creation of an algorithm to ensure patients with significant fractures presenting to the emergency department are seen promptly and treatment expedited as per recent guidance. This includes timing for X-rays taken in A & E. Re-audit has shown significant improvement in both documentation at time of presentation and appropriate follow-up strategies. Within the orthopedic domain, we are in the process of creating an ankle fracture pathway to ensure imaging and weight bearing status are made clear to the consulting clinicians in an outpatient setting. Significance/Clinical Relevance: As a result of the ankle fracture algorithm we have adapted the BOAST 12 guidance to shape an intrinsic pathway to not only improve patient management within the emergency department but also create a standardised format for follow up.

Keywords: ankle, fracture, BOAST, radiology

Procedia PDF Downloads 156
2781 Radiation Protection Assessment of the Emission of a d-t Neutron Generator: Simulations with MCNP Code and Experimental Measurements in Different Operating Conditions

Authors: G. M. Contessa, L. Lepore, G. Gandolfo, C. Poggi, N. Cherubini, R. Remetti, S. Sandri

Abstract:

Practical guidelines are provided in this work for the safe use of a portable d-t Thermo Scientific MP-320 neutron generator producing pulsed 14.1 MeV neutron beams. The neutron generator’s emission was tested experimentally and reproduced by MCNPX Monte Carlo code. Simulations were particularly accurate, even generator’s internal components were reproduced on the basis of ad-hoc collected X-ray radiographic images. Measurement campaigns were conducted under different standard experimental conditions using an LB 6411 neutron detector properly calibrated at three different energies, and comparing simulated and experimental data. In order to estimate the dose to the operator vs. the operating conditions and the energy spectrum, the most appropriate value of the conversion factor between neutron fluence and ambient dose equivalent has been identified, taking into account both direct and scattered components. The results of the simulations show that, in real situations, when there is no information about the neutron spectrum at the point where the dose has to be evaluated, it is possible - and in any case conservative - to convert the measured value of the count rate by means of the conversion factor corresponding to 14 MeV energy. This outcome has a general value when using this type of generator, enabling a more accurate design of experimental activities in different setups. The increasingly widespread use of this type of device for industrial and medical applications makes the results of this work of interest in different situations, especially as a support for the definition of appropriate radiation protection procedures and, in general, for risk analysis.

Keywords: instrumentation and monitoring, management of radiological safety, measurement of individual dose, radiation protection of workers

Procedia PDF Downloads 108
2780 Empirical Analysis of Velocity Behavior for Collaborative Robots in Transient Contact Cases

Authors: C. Schneider, M. M. Seizmeir, T. Suchanek, M. Hutter-Mironovova, M. Bdiwi, M. Putz

Abstract:

In this paper, a suitable measurement setup is presented to conduct force and pressure measurements for transient contact cases at the example of lathe machine tending. Empirical measurements were executed on a selected collaborative robot’s behavior regarding allowable operating speeds under consideration of sensor- and workpiece-specific factors. Comparisons between the theoretic calculations proposed in ISO/TS 15066 and the practical measurement results reveal a basis for future research. With the created database, preliminary risk assessment and economic assessment procedures of collaborative machine tending cells can be facilitated.

Keywords: biomechanical thresholds, collaborative robots, force and pressure measurements, machine tending, transient contact

Procedia PDF Downloads 204
2779 Stature and Gender Estimation Using Foot Measurements in South Indian Population

Authors: Jagadish Rao Padubidri, Mehak Bhandary, Sowmya J. Rao

Abstract:

Introduction: The significance of the human foot and its measurements in identifying an individual has been proved a lot of times by different studies in different geographical areas and its association to the stature and gender of the individual has been justified by many researches. In our study we have used different foot measurements including the length, width, malleol height and navicular height for establishing its association to stature and gender and to find out its accuracy. The purpose of this study is to show the relation of foot measurements with stature and gender, and to derive Multiple and Logistic regression equations for stature and gender estimation in South Indian population. Materials and Methods: The subjects for this study were 200 South Indian students out of which 100 were females and 100 were males, aged between 18 to 24 years. The data for the present study included the stature, foot length, foot breath, foot malleol height, foot navicular height of both right and left foot. Descriptive statistics, T-test and Pearson correlation coefficients were derived between stature, gender and foot measurements. The stature was estimated from right and left foot measurements for both male and female South Indian population using multiple regression analysis and logistic regression analysis for gender estimation. Results: The means, standard deviation, stature, right and left foot measurements and T-test in male population were higher than in females. LFL (Left foot length) is more than RFL (Right Foot length) in male groups, but in female groups the length of both foot are almost equal [RFL=226.6, LFL=227.1]. There is not much of difference in means of RFW (Right foot width) and LFW (Left foot width) in both the genders. Significant difference were seen in mean values of malleol and navicular height of right and left feet in male gender. No such difference was seen in female subjects. Conclusions: The study has successfully demonstrated the correlation of foot length in stature estimation in all the three study groups in both right and left foot. Next in parameters are Foot width and malleol height in estimating stature among male and female groups. Navicular height of both right and left foot showed poor relationship with stature estimation in both male and female groups. Multiple regression equations for both right and left foot measurements to estimate stature were derived with standard error ranging from 11-12 cm in males and 10-11 cm in females. The SEE was 5.8 when both male and female groups were pooled together. The logistic regression model which was derived to determine gender showed 85% accuracy and 92.5% accuracy using right and left foot measurements respectively. We believe that stature and gender can be estimated with foot measurements in South Indian population.

Keywords: foot length, gender, stature, South Indian

Procedia PDF Downloads 309
2778 Quality Assurances for an On-Board Imaging System of a Linear Accelerator: Five Months Data Analysis

Authors: Liyun Chang, Cheng-Hsiang Tsai

Abstract:

To ensure the radiation precisely delivering to the target of cancer patients, the linear accelerator equipped with the pretreatment on-board imaging system is introduced and through it the patient setup is verified before the daily treatment. New generation radiotherapy using beam-intensity modulation, usually associated the treatment with steep dose gradients, claimed to have achieved both a higher degree of dose conformation in the targets and a further reduction of toxicity in normal tissues. However, this benefit is counterproductive if the beam is delivered imprecisely. To avoid shooting critical organs or normal tissues rather than the target, it is very important to carry out the quality assurance (QA) of this on-board imaging system. The QA of the On-Board Imager® (OBI) system of one Varian Clinac-iX linear accelerator was performed through our procedures modified from a relevant report and AAPM TG142. Two image modalities, 2D radiography and 3D cone-beam computed tomography (CBCT), of the OBI system were examined. The daily and monthly QA was executed for five months in the categories of safety, geometrical accuracy and image quality. A marker phantom and a blade calibration plate were used for the QA of geometrical accuracy, while the Leeds phantom and Catphan 504 phantom were used in the QA of radiographic and CBCT image quality, respectively. The reference images were generated through a GE LightSpeed CT simulator with an ADAC Pinnacle treatment planning system. Finally, the image quality was analyzed via an OsiriX medical imaging system. For the geometrical accuracy test, the average deviations of the OBI isocenter in each direction are less than 0.6 mm with uncertainties less than 0.2 mm, while all the other items have the displacements less than 1 mm. For radiographic image quality, the spatial resolution is 1.6 lp/cm with contrasts less than 2.2%. The spatial resolution, low contrast, and HU homogenous of CBCT are larger than 6 lp/cm, less than 1% and within 20 HU, respectively. All tests are within the criteria, except the HU value of Teflon measured with the full fan mode exceeding the suggested value that could be due to itself high HU value and needed to be rechecked. The OBI system in our facility was then demonstrated to be reliable with stable image quality. The QA of OBI system is really necessary to achieve the best treatment for a patient.

Keywords: CBCT, image quality, quality assurance, OBI

Procedia PDF Downloads 270
2777 Adolescent and Adult Hip Dysplasia on Plain Radiographs. Analysis of Measurements and Attempt for Optimization of Diagnostic and Performance Approaches for Patients with Periacetabular Osteotomy (PAO).

Authors: Naum Simanovsky MD, Michael Zaidman MD, Vladimir Goldman MD.

Abstract:

105 plain AP radiographs of normal adult pelvises (210 hips) were evaluated. Different measurements of normal and dysplastic hip joints in 45 patients were analyzed. Attempt was made to establish reproducible, easy applicable in practice approach for evaluation and follow up of patients with hip dysplasia. The youngest of our patients was 11 years and the oldest was 47 years. Only one of our patients needed conversion to total hip replacement (THR) during ten years of follow-up. It was emphasized that selected set of measurements was built for purpose to serve, especially those who’s scheduled or undergone PAO. This approach was based on concept of acetabulum-femoral head complex and importance of reliable reference points of measurements. Comparative analysis of measured parameters between normal and dysplastic hips was performed. Among 10 selected parameters, we use already well established such as lateral center edge angle and head extrusion index, but to serve specific group of patients with PAO, new parameters were considered such as complex lateralization and complex proximal migration. By our opinion proposed approach is easy applicable in busy clinical practice, satisfactorily delineate hip pathology and give to surgeon who’s going to perform PAO guidelines in condensed form. It is also useful tools for postoperative follow up after PAO.

Keywords: periacetabular osteotomy, plain radiograph’s measurements, adolescents, adult

Procedia PDF Downloads 41
2776 Wellbore Spiraling Induced through Systematic Micro-Sliding

Authors: Christopher Viens, Bosko Gajic, Steve Krase

Abstract:

Stick-Slip is a term that is often overused and commonly diagnosed from surface drilling parameters of torque and differential pressure, but the actual magnitude of the condition is rarely captured at the BHA level as the necessary measurements are seldom deployed. Deployment of an accurate stick-slip measurement downhole has led to an interesting discovery that goes against long held traditional drilling lore. A divide has been identified between stick-slip as independent bit and BHA conditions. This phenomenon in horizontal laterals is common, but few M/LWD systems have been able to capture it. Utilizing measurements of downhole RPM bore pressure, high-speed magnetometer data, bending moment, and continuous inclination, the wellbore spiraling phenomenon is able to be captured, quantified, and intimately tied back to systematic effects of BHA stalling and micro-sliding. An operator in the Permian Basin has identified that this phenomenon is contributing to increased tortuosity and drag. Utilizing downhole torque measurements the root causes of the stick-slip and spiraling phenomenon were identified and able to engineered out of the system.

Keywords: bending moment, downhole dynamics measurements, micro sliding, wellbore spiraling

Procedia PDF Downloads 222
2775 FracXpert: Ensemble Machine Learning Approach for Localization and Classification of Bone Fractures in Cricket Athletes

Authors: Madushani Rodrigo, Banuka Athuraliya

Abstract:

In today's world of medical diagnosis and prediction, machine learning stands out as a strong tool, transforming old ways of caring for health. This study analyzes the use of machine learning in the specialized domain of sports medicine, with a focus on the timely and accurate detection of bone fractures in cricket athletes. Failure to identify bone fractures in real time can result in malunion or non-union conditions. To ensure proper treatment and enhance the bone healing process, accurately identifying fracture locations and types is necessary. When interpreting X-ray images, it relies on the expertise and experience of medical professionals in the identification process. Sometimes, radiographic images are of low quality, leading to potential issues. Therefore, it is necessary to have a proper approach to accurately localize and classify fractures in real time. The research has revealed that the optimal approach needs to address the stated problem and employ appropriate radiographic image processing techniques and object detection algorithms. These algorithms should effectively localize and accurately classify all types of fractures with high precision and in a timely manner. In order to overcome the challenges of misidentifying fractures, a distinct model for fracture localization and classification has been implemented. The research also incorporates radiographic image enhancement and preprocessing techniques to overcome the limitations posed by low-quality images. A classification ensemble model has been implemented using ResNet18 and VGG16. In parallel, a fracture segmentation model has been implemented using the enhanced U-Net architecture. Combining the results of these two implemented models, the FracXpert system can accurately localize exact fracture locations along with fracture types from the available 12 different types of fracture patterns, which include avulsion, comminuted, compressed, dislocation, greenstick, hairline, impacted, intraarticular, longitudinal, oblique, pathological, and spiral. This system will generate a confidence score level indicating the degree of confidence in the predicted result. Using ResNet18 and VGG16 architectures, the implemented fracture segmentation model, based on the U-Net architecture, achieved a high accuracy level of 99.94%, demonstrating its precision in identifying fracture locations. Simultaneously, the classification ensemble model achieved an accuracy of 81.0%, showcasing its ability to categorize various fracture patterns, which is instrumental in the fracture treatment process. In conclusion, FracXpert has become a promising ML application in sports medicine, demonstrating its potential to revolutionize fracture detection processes. By leveraging the power of ML algorithms, this study contributes to the advancement of diagnostic capabilities in cricket athlete healthcare, ensuring timely and accurate identification of bone fractures for the best treatment outcomes.

Keywords: multiclass classification, object detection, ResNet18, U-Net, VGG16

Procedia PDF Downloads 36
2774 Retrieving Iconometric Proportions of South Indian Sculptures Based on Statistical Analysis

Authors: M. Bagavandas

Abstract:

Introduction: South Indian stone sculptures are known for their elegance and history. They are available in large numbers in different monuments situated different parts of South India. These art pieces have been studied using iconography details, but this pioneering study introduces a novel method known as iconometry which is a quantitative study that deals with measurements of different parts of icons to find answers for important unanswered questions. The main aim of this paper is to compare iconometric measurements of the sculptures with canonical proportion to determine whether the sculptors of the past had followed any of the canonical proportions prescribed in the ancient text. If not, this study recovers the proportions used for carving sculptures which is not available to us now. Also, it will be interesting to see how these sculptural proportions of different monuments belonging to different dynasties differ from one another in terms these proportions. Methods and Materials: As Indian sculptures are depicted in different postures, one way of making measurements independent of size, is to decode on a suitable measurement and convert the other measurements as proportions with respect to the chosen measurement. Since in all canonical texts of Indian art, all different measurements are given in terms of face length, it is chosen as the required measurement for standardizing the measurements. In order to compare these facial measurements with measurements prescribed in Indian canons of Iconography, the ten facial measurements like face length, morphological face length, nose length, nose-to-chin length, eye length, lip length, face breadth, nose breadth, eye breadth and lip breadth were standardized using the face length and the number of measurements reduced to nine. Each measurement was divided by the corresponding face length and multiplied by twelve and given in angula unit used in the canonical texts. The reason for multiplying by twelve is that the face length is given as twelve angulas in the canonical texts for all figures. Clustering techniques were used to determine whether the sculptors of the past had followed any of the proportions prescribed in the canonical texts of the past to carve sculptures and also to compare the proportions of sculptures of different monuments. About one hundred twenty-seven stone sculptures from four monuments belonging to the Pallava, the Chola, the Pandya and the Vijayanagar dynasties were taken up for this study. These art pieces belong to a period ranging from the eighth to the sixteenth century A.D. and all of them adorning different monuments situated in different parts of Tamil Nadu State, South India. Anthropometric instruments were used for taking measurements and the author himself had measured all the sample pieces of this study. Result: Statistical analysis of sculptures of different centers of art from different dynasties shows a considerable difference in facial proportions and many of these proportions differ widely from the canonical proportions. The retrieved different facial proportions indicate that the definition of beauty has been changing from period to period and region to region.

Keywords: iconometry, proportions, sculptures, statistics

Procedia PDF Downloads 136
2773 Quartz Crystal Microbalance Holder Design for On-Line Sensing in Liquid Applications

Authors: M. A. Amer, J. A. Chávez, M. J. García-Hernández, J. Salazar, A. Turó

Abstract:

In this paper, the design of a QCM sensor for liquid media measurements in vertical position is described. A rugged and low-cost proof holder has been designed, the cost of which is significantly lower than those of traditional commercial holders. The crystal is not replaceable but it can be easily cleaned. Its small volume permits to be used by dipping it in the liquid with the desired location and orientation. The developed design has been experimentally validated by measuring changes in the resonance frequency and resistance of the QCM sensor immersed vertically in different calibrated aqueous glycerol solutions. The obtained results show a great agreement with the Kanazawa theoretical expression. Consequently, the designed QCM sensor would be appropriate for sensing applications in liquids, and might take part of a future on-line multichannel low-cost QCM-based measurement system.

Keywords: holder design, liquid-media measurements, multi-channel measurements, QCM

Procedia PDF Downloads 357
2772 Study on the Electrochemical Performance of Graphene Effect on Cadmium Oxide in Lithium Battery

Authors: Atef Y. Shenouda, Anton A. Momchilov

Abstract:

Graphene and CdO with different stoichiometric ratios of Cd(CH₃COO)₂ and graphene samples were prepared by hydrothermal reaction. The crystalline phases of pure CdO and 3CdO:1graphene were identified by X-ray diffraction (XRD). The particle morphology was studied with SEM. Furthermore, impedance measurements were applied. Galvanostatic measurements for the cells were carried out using potential limits between 0.01 and 3 V vs. Li/Li⁺. The current cycling intensity was 10⁻⁴ A. The specific discharge capacity of 3CdO-1G cell was about 450 Ah.Kg⁻¹ up to more than 100 cycles.

Keywords: CdO, graphene, negative electrode, lithium battery

Procedia PDF Downloads 125
2771 Comparison of Corneal Curvature Measurements Conducted with Tomey AO-2000® and the Current Standard Biometer IOL Master®

Authors: Mohd Radzi Hilmi, Khairidzan Mohd Kamal, Che Azemin Mohd Zulfaezal, Ariffin Azrin Esmady

Abstract:

Purpose: Corneal curvature (CC) is an important anterior segment parameter. This study compared CC measurements conducted with two optical devices in phakic eyes. Methods: Sixty phakic eyes of 30 patients were enrolled in this study. CC was measured three times with the optical biometer and topography-keratometer Tomey AO-2000 (Tomey Corporation, Nagoya, Japan), then with the standard partial optical coherence interferometry (PCI) IOL Master (Carl Zeiss Meditec, Dublin, CA) and data were statistically analysed. Results: The measurements resulted in a mean CC of 43.86 ± 1.57 D with Tomey AO-2000 and 43.84 ± 1.55 D with IOL Master. Distribution of data is normal, and no significance difference in CC values was detected (P = 0.952) between the two devices. Correlation between CC measurements was highly significant (r = 0. 99; P < 0.0001). The mean difference of CC values between devices was 0.017 D and 95% limit of agreement was -0.088 to 0.12. Duration taken for measurements with the standard biometer IOL Master was longer (55.17 ± 2.24 seconds) than with Tomey AO-2000 (39.88 ± 2.38 seconds) in automatic mode. Duration of manual measurement with Tomey AO-2000 in manual mode was the shortest (28.57 ± 2.71 seconds). Conclusion: In phakic eyes, CC measured with Tomey AO-2000 and IOL Master showed similar values, and high correlation was observed between these two devices. This shows that both devices can be used interchangeably. Tomey AO-2000 is better in terms of faster to operate and has its own topography systems.

Keywords: corneal topography, corneal curvature, IOL Master, Tomey AO2000

Procedia PDF Downloads 355