Search results for: median sacral crest
612 Changes in the Median Sacral Crest Associated with Sacrocaudal Fusion in the Greyhound
Authors: S. M. Ismail, H-H Yen, C. M. Murray, H. M. S. Davies
Abstract:
A recent study reported a 33% incidence of complete sacrocaudal fusion in greyhounds compared to a 3% incidence in other dogs. In the dog, the median sacral crest is formed by the fusion of sacral spinous processes. Separation of the 1st spinous process from the median crest of the sacrum in the dog has been reported as a diagnostic tool of type one lumbosacral transitional vertebra (LTV). LTV is a congenital spinal anomaly, which includes either sacralization of the caudal lumbar part or lumbarization of the most cranial sacral segment of the spine. In this study, the absence or reduction of fusion (presence of separation) between the 1st and 2ndspinous processes of the median sacral crest has been identified in association with sacrocaudal fusion in the greyhound, without any feature of LTV. In order to provide quantitative data on the absence or reduction of fusion in the median sacral crest between the 1st and 2nd sacral spinous processes, in association with sacrocaudal fusion. 204 dog sacrums free of any pathological changes (192 greyhound, 9 beagles and 3 labradors) were grouped based on the occurrence and types of fusion and the presence, absence, or reduction in the median sacral crest between the 1st and 2nd sacral spinous processes., Sacrums were described and classified as follows: F: Complete fusion (crest is present), N: Absence (fusion is absent), and R: Short crest (fusion reduced but not absent (reduction). The incidence of sacrocaudal fusion in the 204 sacrums: 57% of the sacrums were standard (3 vertebrae) and 43% were fused (4 vertebrae). Type of sacrum had a significant (p < .05) association with the absence and reduction of fusion between the 1st and 2nd sacral spinous processes of the median sacral crest. In the 108 greyhounds with standard sacrums (3 vertebrae) the percentages of F, N and R were 45% 23% and 23% respectively, while in the 84 fused (4 vertebrae) sacrums, the percentages of F, N and R were 3%, 87% and 10% respectively and these percentages were significantly different between standard (3 vertebrae) and fused (4 vertebrae) sacrums (p < .05). This indicates that absence of spinous process fusion in the median sacral crest was found in a large percentage of the greyhounds in this study and was found to be particularly prevalent in those with sacrocaudal fusion – therefore in this breed, at least, absence of sacral spinous process fusion may be unlikely to be associated with LTV.Keywords: greyhound, median sacral crest, sacrocaudal fusion, sacral spinous process
Procedia PDF Downloads 446611 Variations in the Angulation of the First Sacral Spinous Process Angle Associated with Sacrocaudal Fusion in Greyhounds
Authors: Sa'ad M. Ismail, Hung-Hsun Yen, Christina M. Murray, Helen M. S. Davies
Abstract:
In the dog, the median sacral crest is formed by the fusion of three sacral spinous processes. In greyhounds with standard sacrums, this fusion in the median sacral crest consists of the fusion of three sacral spinous processes while it consists of four in greyhounds with sacrocaudal fusion. In the present study, variations in the angulation of the first sacral spinous process in association with different types of sacrocaudal fusion in the greyhound were investigated. Sacrums were collected from 207 greyhounds (102 sacrums; type A (unfused) and 105 with different types of sacrocaudal fusion; types: B, C and D). Sacrums were cleaned by boiling and dried and then were placed on their ventral surface on a flat surface and photographed from the left side using a digital camera at a fixed distance. The first sacral spinous process angle (1st SPA) was defined as the angle formed between the cranial border of the cranial ridge of the first sacral spinous process and the line extending across the most dorsal surface points of the spinous processes of the S1, S2, and S3. Image-Pro Express Version 5.0 imaging software was used to draw and measure the angles. Two photographs were taken for each sacrum and two repeat measurements were also taken of each angle. The mean value of the 1st SPA in greyhounds with sacrocaudal fusion was less (98.99°, SD ± 11, n = 105) than those in greyhounds with standard sacrums (99.77°, SD ± 9.18, n = 102) but was not significantly different (P < 0.05). Among greyhounds with different types of sacrocaudal fusion the mean value of the 1st SPA was as follows: type B; 97.73°, SD ± 10.94, n = 39, type C: 101.42°, SD ± 10.51, n = 52, and type D: 94.22°, SD ± 11.30, n = 12. For all types of fusion these angles were significantly different from each other (P < 0.05). Comparing the mean value of the1st SPA in standard sacrums (Type A) with that for each type of fusion separately showed that the only significantly different angulation (P < 0.05) was between standard sacrums and sacrums with sacrocaudal fusion sacrum type D (only body fusion between the S1 and Ca1). Different types of sacrocaudal fusion were associated with variations in the angle of the first sacral spinous process. These variations may affect the alignment and biomechanics of the sacral area and the pattern of movement and/or the force produced by both hind limbs to the cranial parts of the body and may alter the loading of other parts of the body. We concluded that any variations in the sacrum anatomical features might change the function of the sacrum or surrounding anatomical structures during movement.Keywords: angulation of first sacral spinous process, biomechanics, greyhound, locomotion, sacrocaudal fusion
Procedia PDF Downloads 311610 Variations in the 7th Lumbar (L7) Vertebra Length Associated with Sacrocaudal Fusion in Greyhounds
Authors: Sa`ad M. Ismail, Hung-Hsun Yen, Christina M. Murray, Helen M. S. Davies
Abstract:
The lumbosacral junction (where the 7th lumbar vertebra (L7) articulates with the sacrum) is a clinically important area in the dog. The 7th lumbar vertebra (L7) is normally shorter than other lumbar vertebrae, and it has been reported that variations in the L7 length may be associated with other abnormal anatomical findings. These variations included the reduction or absence of the portion of the median sacral crest. In this study, 53 greyhound cadavers were placed in right lateral recumbency, and two lateral radiographs were taken of the lumbosacral region for each greyhound. The length of the 6th lumbar (L6) vertebra and L7 were measured using radiographic measurement software and was defined to be the mean of three lines drawn from the caudal to the cranial edge of the L6 and L7 vertebrae (a dorsal, middle, and ventral line) between specific landmarks. Sacrocaudal fusion was found in 41.5% of the greyhounds. The mean values of the length of L6, L7, and the ratio of the L6/L7 length of the greyhounds with sacrocaudal fusion were all greater than those with standard sacrums (three sacral vertebrae). There was a significant difference (P < 0.05) in the mean values of the length of L7 between the greyhounds without sacrocaudal fusion (mean = 29.64, SD ± 2.07) and those with sacrocaudal fusion (mean = 30.86, SD ± 1.80), but, there was no significant difference in the mean value of the length of the L6 measurement. Among different types of sacrocaudal fusion, the longest L7 was found in greyhounds with sacrum type D, intermediate length in those with sacrum type B, and the shortest was found in those with sacrums type C, and the mean values of the ratio of the L6/L7 were 1.11 (SD ± 0.043), 1.15, (SD ± 0.025), and 1.15 (SD ± 0.011) for the types B, C, and D respectively. No significant differences in the mean values of the length of L6 or L7 were found among the different types of sacrocaudal fusion. The occurrence of sacrocaudal fusion might affect direct anatomically connected structures such as the L7. The variation in the length of L7 between greyhounds with sacrocaudal fusion and those without may reflect the possible sequences of the process of fusion. Variations in the length of the L7 vertebra in greyhounds may be associated with the occurrence of sacrocaudal fusion. The variation in the vertebral length may affect the alignment and biomechanical properties of the sacrum and may alter the loading. We concluded that any variations in the sacrum anatomical features might change the function of the sacrum or the surrounding anatomical structures.Keywords: biomechanics, Greyhound, sacrocaudal fusion, locomotion, 6th Lumbar (L6) Vertebra, 7th Lumbar (L7) Vertebra, ratio of the L6/L7 length
Procedia PDF Downloads 371609 Topping Failure Analysis of Anti-Dip Bedding Rock Slopes Subjected to Crest Loads
Authors: Chaoyi Sun, Congxin Chen, Yun Zheng, Kaizong Xia, Wei Zhang
Abstract:
Crest loads are often encountered in hydropower, highway, open-pit and other engineering rock slopes. Toppling failure is one of the most common deformation failure types of anti-dip bedding rock slopes. Analysis on such failure of anti-dip bedding rock slopes subjected to crest loads has an important influence on engineering practice. Based on the step-by-step analysis approach proposed by Goodman and Bray, a geo-mechanical model was developed, and the related analysis approach was proposed for the toppling failure of anti-dip bedding rock slopes subjected to crest loads. Using the transfer coefficient method, a formulation was derived for calculating the residual thrust of slope toe and the support force required to meet the requirements of the slope stability under crest loads, which provided a scientific reference to design and support for such slopes. Through slope examples, the influence of crest loads on the residual thrust and sliding ratio coefficient was investigated for cases of different block widths and slope cut angles. The results show that there exists a critical block width for such slope. The influence of crest loads on the residual thrust is non-negligible when the block thickness is smaller than the critical value. Moreover, the influence of crest loads on the slope stability increases with the slope cut angle and the sliding ratio coefficient of anti-dip bedding rock slopes increases with the crest loads. Finally, the theoretical solutions and numerical simulations using Universal Distinct Element Code (UDEC) were compared, in which the consistent results show the applicability of both approaches.Keywords: anti-dip bedding rock slope, crest loads, stability analysis, toppling failure
Procedia PDF Downloads 176608 Fracture Dislocation of Upper Sacrum in an Adolescent: Case Report and Review of Literature
Authors: S. Alireza Mirghasemi, Narges Rahimi Gabaran
Abstract:
Although sacral fractures in children are rare due to the fact that the occurrence of pelvic fracture is not common in childhood. Sacral fractures present a high risk of neurological damage. This kind of fracture is often missed because the routine pelvic X-rays imaging scarcely show this fracture. Also, the treatment is controversial, and it ranges from fine reduction to conservative treatments without any try to reduce the dislocation. In this article, a case of fracture dislocation of S1 and S2 along with a suggested diagnostic test and treatment based on similar cases are presented. The case investigates a 14-year-old boy who entered the hospital one week after a car accident that knocked him to the ground in crawling position and a rack fell down on his body. Pain and tenderness in the sacral region and a fracture in the left leg were notable--we detected incomplete bilateral palsy of L5, S1 and S2 roots. In radiographs of the spine fracture dislocation of S1, the sacral fracture was seen. The treatment included a skeletal traction with a halo over the patient’s head and two femoral pins. After one week, another surgery was performed in order to stabilize and reduce the fracture, and we employed a posterior approach with CD and a pedicular screw. After two years of follow-up, the fracture is completely cured without any loss of reduction.Keywords: adolescent, fracture in adolescent, fracture dislocation, sacrum
Procedia PDF Downloads 292607 Transcranial and Sacral Magnetic Stimulation as a Therapeutic Resource for Urinary Incontinence – A Brief Bibliographic Review
Authors: Ana Lucia Molina
Abstract:
Transcranial magnetic stimulation (TMS) is a non-invasive neuromodulation technique for the investigation and modulation of cortical excitability in humans. The modulation of the processing of different cortical areas can result in several areas for rehabilitation, showing great potential in the treatment of motor disorders. In the human brain, the supplementary motor area (SMA) is involved in the control of the pelvic floor muscles (MAP), where dysfunctions of these muscles can lead to urinary incontinence. Peripheral magnetic stimulation, specifically sacral magnetic stimulation, has been used as a safe and effective treatment option for patients with lower urinary tract dysfunction. A systematic literature review was carried out (Pubmed, Medline and Google academic database) without a time limit using the keywords: "transcranial magnetic stimulation", "sacral neuromodulation", and "urinary incontinence", where 11 articles attended to the inclusion criteria. Results: Thirteen articles were selected. Magnetic stimulation is a non-invasive neuromodulation technique widely used in the evaluation of cortical areas and their respective peripheral areas, as well as in the treatment of lesions of brain origin. With regard to pelvic-perineal disorders, repetitive transcranial stimulation showed significant effects in controlling urinary incontinence, as well as sacral peripheral magnetic stimulation, in addition to exerting the potential to restore bladder sphincter function. Conclusion: Data from the literature suggest that both transcranial stimulation and peripheral stimulation are non-invasive references that can be promising and effective means of treatment in pelvic and perineal disorders. More prospective and randomized studies on a larger scale are needed, adapting the most appropriate and resolving parameters.Keywords: urinary incontinence, non-invasive neuromodulation, sacral neuromodulation, transcranial magnetic stimulation.
Procedia PDF Downloads 97606 Anatomical Characteristics of Superior Gluteal Artery
Authors: Nawaf Al-Kharashi, Waseem Al-Talalwah, Shorok Al Dorazi, Roger Soames
Abstract:
Superior gluteal artery is one of the largest branches of posterior division of the internal iliac artery. It passes between the lumbosacral and first sacral root to escape from the pelvic cavity through the grater sciatic foramen just above the piriformis. The current study includes 41 cadaver investigates the origin and branch of the superior gluteal artery and clarify the clinical significance. In present study, the superior gluteal artery arises from the posterior division of the internal iliac artery directly in 82.5% whereas it arises indirectly as from the sciatic artery in 15.9%. However, it is congenital absence in 1.6% which is compensated by sciatic artery. The sciatic nerve gains vascular supply from superior gluteal artery in two ways either during its course or giving lateral sacral artery in 27% and lumbar branches in 1.6%. It also supplies the adductors group and iliacus via giving obturator artery in 14.3% and in 1.6% respectively. The superior gluteal artery usually passes between lumbosacral trunk and first sacral root in 82.5% whereas it does not passes the sciatic roots as it arises behind them in 15.9%. With a variability of the superior gluteal artery origin, there is a variability of sciatic nerve roots supply. Further, the superior gluteal artery arising from sciatic artery behind the sciatic roots carries a high risk of intra-pelvic bleeding in case of posterior pelvic fracture. Prolonged ligation of the superior gluteal artery which gives lateral sacral artery may result in sciatic neuropathy. Therefore, surgeons have to be aware of the superior gluteal artery variation in origin, course and branches to reduce the iatrogenic faults.Keywords: internal pudendal artery, inferior gluteal artery, superior gluteal artery, internal iliac artery. sciatic neuropathy, sciatic nerve
Procedia PDF Downloads 350605 Impact of Hard Limited Clipping Crest Factor Reduction Technique on Bit Error Rate in OFDM Based Systems
Authors: Theodore Grosch, Felipe Koji Godinho Hoshino
Abstract:
In wireless communications, 3GPP LTE is one of the solutions to meet the greater transmission data rate demand. One issue inherent to this technology is the PAPR (Peak-to-Average Power Ratio) of OFDM (Orthogonal Frequency Division Multiplexing) modulation. This high PAPR affects the efficiency of power amplifiers. One approach to mitigate this effect is the Crest Factor Reduction (CFR) technique. In this work, we simulate the impact of Hard Limited Clipping Crest Factor Reduction technique on BER (Bit Error Rate) in OFDM based Systems. In general, the results showed that CFR has more effects on higher digital modulation schemes, as expected. More importantly, we show the worst-case degradation due to CFR on QPSK, 16QAM, and 64QAM signals in a linear system. For example, hard clipping of 9 dB results in a 2 dB increase in signal to noise energy at a 1% BER for 64-QAM modulation.Keywords: bit error rate, crest factor reduction, OFDM, physical layer simulation
Procedia PDF Downloads 365604 Median Versus Ulnar Medial Thenar Motor Recording in Diagnosis Of Carpal Tunnel Syndrome
Authors: Emmanuel Kamal Aziz Saba
Abstract:
Aim of the work: This study proposed to assess the role of the median versus ulnar medial thenar motor (MTM) recording in supporting the diagnosis of carpal tunnel syndrome (CTS). Patients and methods: The present study included 130 hands (70 CTS and 60 controls). Clinical examination was done for all patients. The following tests were done (using surface electrodes recording) for patients and control: (1) sensory nerve conduction studies: median nerve, ulnar nerve and median versus ulnar digit four sensory study; (2) motor nerve conduction studies: median nerve, ulnar nerve, median (second lumbrical) versus ulnar (interosseous) (2-LINT) motor study and median versus ulnar (MTM) study. Results: The tests with higher sensitivity in diagnosing CTS were median versus ulnar (2-LINT) motor latency difference (87.1%), median versus ulnar (MTM) motor latency difference (80%) and median versus ulnar digit four sensory latency differences (91.4%). There was no statistically significant difference between median versus ulnar (MTM) motor latency difference with both median versus ulnar (2-LINT) motor latency difference and median versus ulnar digit four sensory latency difference (P > 0.05) as regards the confirmation of CTS. Conclusions: Median versus ulnar (MTM) motor latency difference has high sensitivity and specificity for the diagnosis of CTS as for both median versus ulnar (2-LINT) motor latency difference and median versus ulnar digit four sensory latency differences. It can be considered a useful neurophysiological test to be used in combination with another median versus ulnar comparative tests for confirming the diagnosis of CTS beside other well-known electrophysiological tests.Keywords: carpal tunnel syndrome, medial thenar motor, median nerve, ulnar nerve
Procedia PDF Downloads 440603 Speed up Vector Median Filtering by Quasi Euclidean Norm
Authors: Vinai K. Singh
Abstract:
For reducing impulsive noise without degrading image contours, median filtering is a powerful tool. In multiband images as for example colour images or vector fields obtained by optic flow computation, a vector median filter can be used. Vector median filters are defined on the basis of a suitable distance, the best performing distance being the Euclidean. Euclidean distance is evaluated by using the Euclidean norms which is quite demanding from the point of view of computation given that a square root is required. In this paper an optimal piece-wise linear approximation of the Euclidean norm is presented which is applied to vector median filtering.Keywords: euclidean norm, quasi euclidean norm, vector median filtering, applied mathematics
Procedia PDF Downloads 473602 The Effect of Jet Grouting on the Behavior of Strip Footing Adjacent to Slope Crest
Authors: Ahmed M. El-Tuhami, Ahmed A. Mohamed
Abstract:
This paper studies the behavior of strip footing adjacent to slope crest and the effect of jet grouting under the footing. This problem is investigated numerically in the present study. Two dimensional plane strain program PLAXIS is used in this study. 15 nodes triangular element is used to idealize soil with hardening soil model. Five nodes isoperimetric beam element is used to idealize stripe footing. Interface element is used to represent the contact between beam element and soil. Two parameters were studied, the first is the foundation depth and the second is the Stripe footing distance from the slope crest. Settlement and horizontal displacement of strip footing were obtained and studied from the analyzed finite element model results. The reduction influence of jet grouting on footing displacement were studied and investigated. The results indicate that the inclusion of jet grouting under strip footing adjacent to slope crest has significant effect in improving the response of the strip footing and the slope.Keywords: strip footing, jet grouting, slope, PLAXIS, relative distance
Procedia PDF Downloads 475601 Clinical and Radiographic Evaluation of Split-Crest Technique by Ultrasonic Bone Surgery Combined with Platelet Concentrates Prior to Dental Implant Placement
Authors: Ahmed Mohamed El-Shamy, Akram Abbas El-Awady, Mahmoud Taha Eldestawy
Abstract:
Background: The present study was to evaluate clinically and radiographically the combined effect of split crest technique by ultrasonic bone surgery and platelet concentrates in implant site development. Methods: Forty patients with narrow ridge were participated in this study. Patients were assigned randomly into one of the following four groups according to treatment: Group 1: Patients received split-crest technique by ultrasonic bone surgery with implant placement. Group 2: Patients received split-crest technique by ultrasonic bone surgery with implant placement and PRF. Group 3: Patients received split-crest technique by ultrasonic bone surgery with implant placement and PRP. Group 4: Patients received split-crest technique by ultrasonic bone surgery with implant placement and collagen membrane. Modified plaque index, modified sulcus bleeding index, and implant stability were recorded as a baseline and measured again at 3 and 6 months. CBCT scans were taken immediately after surgery completion and at 9 months to evaluate bone density at the bone-implant interface. Results after 6 months; collagen group showed statistically significantly lower mean modified bleeding index than the other groups. After 3 months, the PRF group showed statistically significantly higher mean implant stability with ostell ISQ units' than the other groups. After 6 months, the PRF group showed statistically significantly higher mean implant stability with ostell ISQ units' than the other groups. After 6 months, the PRF group showed statistically significantly higher mean bone density than the collagen group. Conclusion: Ultrasonic bone surgery in split-crest technique can be a successful option for increasing implant stability values throughout the healing period. The use of a combined technique of ultrasonic bone surgery with PRF and simultaneous implant placement potentially improves osseointegration (bone density). PRF membranes represent advanced technology for the stimulation and acceleration of bone regeneration.Keywords: dental implants, split-crest, PRF, PRP
Procedia PDF Downloads 160600 The Effect of the Side-Weir Crest Height to Scour in Clay-Sand Mixed Sediments
Authors: F. A. Saracoglu Varol, H. Agaccıoglu
Abstract:
Experimental studies to investigate the depth of the scour conducted at a side-weir intersection located at the 1800 curved flume which located Hydraulic Laboratory of Yıldız Technical University, Istanbul, Turkey. Side weirs were located at the middle of the straight part of the main channel. Three different lengths (25, 40 and 50 cm) and three different weir crest height (7, 10 and 12 cm) of the side weir placed on the side weir station. There is no scour when the material is only kaolin. Therefore, the cohesive bed was prepared by properly mixing clay material (kaolin) with 31% sand in all experiments. Following 24h consolidation time, in order to observe the effect of flow intensity on the scour depth, experiments were carried out for five different upstream Froude numbers in the range of 0.33-0.81. As a result of this study the relation between scour depth and upstream flow intensity as a function of time have been established. The longitudinal velocities decreased along the side weir; towards the downstream due to overflow over the side-weirs. At the beginning, the scour depth increases rapidly with time and then asymptotically approached constant values in all experiments for all side weir dimensions as in non-cohesive sediment. Thus, the scour depth reached equilibrium conditions. Time to equilibrium depends on the approach flow intensity and the dimensions of side weirs. For different heights of the weir crest, dimensionless scour depths increased with increasing upstream Froude number. Equilibrium scour depths which formed 7 cm side-weir crest height were obtained higher than that of the 12 cm side-weir crest height. This means when side-weir crest height increased equilibrium scour depths decreased. Although the upstream side of the scour hole is almost vertical, the downstream side of the hole is inclined.Keywords: clay-sand mixed sediments, scour, side weir, hydraulic structures
Procedia PDF Downloads 308599 Ulnar Nerve Changes Associated with Carpal Tunnel Syndrome Not Affecting Median versus Ulnar Comparative Studies
Authors: Emmanuel Kamal Aziz Saba, Sarah Sayed El-Tawab
Abstract:
The present study was conducted to assess the involvement of ulnar sensory and/or motor nerve fibers in patients with carpal tunnel syndrome (CTS) and whether this affects the accuracy of the median versus ulnar comparative tests. The present study included 145 CTS hands and 71 asymptomatic control hands. Clinical examination was done. The following tests were done: Sensory conduction studies: median, ulnar and dorsal ulnar cutaneous nerves; and median versus ulnar digit (D) four sensory comparative study; and motor conduction studies: median nerve, ulnar nerve and median versus ulnar motor comparative study. It was found that 17 CTS hands (11.7%) had ulnar sensory abnormalities in 17 different patients. The median versus ulnar sensory and motor comparative studies were abnormal among all these 17 CTS hands. There were significant negative correlations between median motor latency and both ulnar sensory amplitudes recording D5 and D4. In conclusion, there is ulnar sensory nerve abnormality among CTS patients. This abnormality affects the amplitude of ulnar sensory nerve action potential. This does not affect the median versus ulnar sensory and motor comparative tests accuracy for use in CTS.Keywords: median nerve, motor comparative study, sensory comparative study, ulnar nerve
Procedia PDF Downloads 428598 A Rare Case of Clinically Amyopathic Dermatomyositis in a Filipino Female
Authors: Rene A. Amadore Jr., Ramar John Bangayan, Therese Eileen L. Natividad
Abstract:
This is a case of a 59-year-old female who presented with a two-year history of heliotrope rash, Gottron's papules, shawl sign, V-neck sign, and muscle weakness. She was previously managed as a case of systemic lupus erythematosus, who initially responded to unrecalled corticosteroids. She was, however, admitted due to a one-month progressively enlarging sacral mass, which eventually turned out to be an abscess. While the abscess was being treated, her autoimmune condition was worked up, and she was then managed as a case of clinically amyopathic dermatomyositis (CADM) with interstitial lung disease (ILD). She received corticosteroids and underwent the first cycle of cyclophosphamide infusion prior to discharge.Keywords: clinically amyopathic dermatomyositis, interstitial lung disease, corticosteroids, sacral abscess
Procedia PDF Downloads 138597 An Accidental Forecasting Modelling for Various Median Roads
Authors: Pruethipong Xinghatiraj, Rajwanlop Kumpoopong
Abstract:
Considering the current situation of road safety, Thailand has the world’s second-highest road fatality rate. Therefore, decreasing the road accidents in Thailand is a prime policy of the Thai government seeking to accomplish. One of the approaches to reduce the accident rate is to improve road environments to fit with the local behavior of the road users. The Department of Highways ensures that choosing the road median types right to the road characteristics, e.g. roadside characteristics, traffic volume, truck traffic percentage, etc., can decrease the possibility of accident occurrence. Presently, raised median, depressed median, painted median and median barriers are typically used in Thailand Highways. In this study, factors affecting road accident for each median type will be discovered through the analysis of the collecting of accident data, death numbers on sample of 600 Kilometers length across the country together with its roadside characteristics, traffic volume, heavy vehicles percentage, and other key factors. The benefits of this study can assist the Highway designers to select type of road medians that can match local environments and then cause less accident prone.Keywords: highways, road safety, road median, forecasting model
Procedia PDF Downloads 264596 Novel Algorithm for Restoration of Retina Images
Authors: P. Subbuthai, S. Muruganand
Abstract:
Diabetic Retinopathy is one of the complicated diseases and it is caused by the changes in the blood vessels of the retina. Extraction of retina image through Fundus camera sometimes produced poor contrast and noises. Because of this noise, detection of blood vessels in the retina is very complicated. So preprocessing is needed, in this paper, a novel algorithm is implemented to remove the noisy pixel in the retina image. The proposed algorithm is Extended Median Filter and it is applied to the green channel of the retina because green channel vessels are brighter than the background. Proposed extended median filter is compared with the existing standard median filter by performance metrics such as PSNR, MSE and RMSE. Experimental results show that the proposed Extended Median Filter algorithm gives a better result than the existing standard median filter in terms of noise suppression and detail preservation.Keywords: fundus retina image, diabetic retinopathy, median filter, microaneurysms, exudates
Procedia PDF Downloads 341595 Parametric Estimation of U-Turn Vehicles
Authors: Yonas Masresha Aymeku
Abstract:
The purpose of capacity modelling at U-turns is to develop a relationship between capacity and its geometric characteristics. In fact, the few models available for the estimation of capacity at different transportation facilities do not provide specific guidelines for median openings. For this reason, an effort is made to estimate the capacity by collecting the data sets from median openings at different lane roads in Hyderabad City, India. Wide difference (43% -59%) among the capacity values estimated by the existing models shows the limitation to consider for mixed traffic situations. Thus, a distinct model is proposed for the estimation of the capacity of U-turn vehicles at median openings considering mixed traffic conditions, which would further prompt to investigate the effect of different factors that might affect the capacity.Keywords: geometric, guiddelines, median, vehicles
Procedia PDF Downloads 65594 A Semi-Automated GIS-Based Implementation of Slope Angle Design Reconciliation Process at Debswana Jwaneng Mine, Botswana
Authors: K. Mokatse, O. M. Barei, K. Gabanakgosi, P. Matlhabaphiri
Abstract:
The mining of pit slopes is often associated with some level of deviation from design recommendations, and this may translate to associated changes in the stability of the excavated pit slopes. Therefore slope angle design reconciliations are essential for assessing and monitoring compliance of excavated pit slopes to accepted slope designs. These associated changes in slope stability may be reflected by changes in the calculated factors of safety and/or probabilities of failure. Reconciliations of as-mined and slope design profiles are conducted periodically to assess the implications of these deviations on pit slope stability. Currently, the slope design reconciliation process being implemented in Jwaneng Mine involves the measurement of as-mined and design slope angles along vertical sections cut along the established geotechnical design section lines on the GEOVIA GEMS™ software. Bench retentions are calculated as a percentage of the available catchment area, less over-mined and under-mined areas, to that of the designed catchment area. This process has proven to be both tedious and requires a lot of manual effort and time to execute. Consequently, a new semi-automated mine-to-design reconciliation approach that utilizes laser scanning and GIS-based tools is being proposed at Jwaneng Mine. This method involves high-resolution scanning of targeted bench walls, subsequent creation of 3D surfaces from point cloud data and the derivation of slope toe lines and crest lines on the Maptek I-Site Studio software. The toe lines and crest lines are then exported to the ArcGIS software where distance offsets between the design and actual bench toe lines and crest lines are calculated. Retained bench catchment capacity is measured as distances between the toe lines and crest lines on the same bench elevations. The assessment of the performance of the inter-ramp and overall slopes entails the measurement of excavated and design slope angles along vertical sections on the ArcGIS software. Excavated and design toe-to-toe or crest-to-crest slope angles are measured for inter-ramp stack slope reconciliations. Crest-to-toe slope angles are also measured for overall slope angle design reconciliations. The proposed approach allows for a more automated, accurate, quick and easier workflow for carrying out slope angle design reconciliations. This process has proved highly effective and timeous in the assessment of slope performance in Jwaneng Mine. This paper presents a newly proposed process for assessing compliance to slope angle designs for Jwaneng Mine.Keywords: slope angle designs, slope design recommendations, slope performance, slope stability
Procedia PDF Downloads 232593 Ulnar Nerve Changes Associated with Carpal Tunnel Syndrome and Effect on Median Ersus Ulnar Comparative Studies
Authors: Emmanuel K. Aziz Saba, Sarah S. El-Tawab
Abstract:
Objectives: Carpal tunnel syndrome (CTS) was found to be associated with high pressure within the Guyon’s canal. The aim of this study was to assess the involvement of sensory and/or motor ulnar nerve fibers in patients with CTS and whether this affects the accuracy of the median versus ulnar sensory and motor comparative tests. Patients and methods: The present study included 145 CTS hands and 71 asymptomatic control hands. Clinical examination was done for all patients. The following tests were done for the patients and control: (1) Sensory conduction studies: median nerve, ulnar nerve, dorsal ulnar cutaneous nerve and median versus ulnar digit (D) four sensory comparative study; (2) Motor conduction studies: median nerve, ulnar nerve and median versus ulnar motor comparative study. Results: There were no statistically significant differences between patients and control group as regards parameters of ulnar motor study and dorsal ulnar cutaneous sensory conduction study. It was found that 17 CTS hands (11.7%) had ulnar sensory abnormalities in 17 different patients. The median versus ulnar sensory and motor comparative studies were abnormal among all these 17 CTS hands. There were statistically significant negative correlations between median motor latency and both ulnar sensory amplitudes recording D5 and D4. There were statistically significant positive correlations between median sensory conduction velocity and both ulnar sensory nerve action potential amplitude recording D5 and D4. Conclusions: There is ulnar sensory nerve abnormality among CTS patients. This abnormality affects the amplitude of ulnar sensory nerve action potential. The presence of abnormalities in ulnar nerve occurs in moderate and severe degrees of CTS. This does not affect the median versus ulnar sensory and motor comparative tests accuracy and validity for use in electrophysiological diagnosis of CTS.Keywords: carpal tunnel syndrome, ulnar nerve, median nerve, median versus ulnar comparative study, dorsal ulnar cutaneous nerve
Procedia PDF Downloads 566592 Constant Factor Approximation Algorithm for p-Median Network Design Problem with Multiple Cable Types
Authors: Chaghoub Soraya, Zhang Xiaoyan
Abstract:
This research presents the first constant approximation algorithm to the p-median network design problem with multiple cable types. This problem was addressed with a single cable type and there is a bifactor approximation algorithm for the problem. To the best of our knowledge, the algorithm proposed in this paper is the first constant approximation algorithm for the p-median network design with multiple cable types. The addressed problem is a combination of two well studied problems which are p-median problem and network design problem. The introduced algorithm is a random sampling approximation algorithm of constant factor which is conceived by using some random sampling techniques form the literature. It is based on a redistribution Lemma from the literature and a steiner tree problem as a subproblem. This algorithm is simple, and it relies on the notions of random sampling and probability. The proposed approach gives an approximation solution with one constant ratio without violating any of the constraints, in contrast to the one proposed in the literature. This paper provides a (21 + 2)-approximation algorithm for the p-median network design problem with multiple cable types using random sampling techniques.Keywords: approximation algorithms, buy-at-bulk, combinatorial optimization, network design, p-median
Procedia PDF Downloads 202591 Additive White Gaussian Noise Filtering from ECG by Wiener Filter and Median Filter: A Comparative Study
Authors: Hossein Javidnia, Salehe Taheri
Abstract:
The Electrocardiogram (ECG) is the recording of the heart’s electrical potential versus time. ECG signals are often contaminated with noise such as baseline wander and muscle noise. As these signals have been widely used in clinical studies to detect heart diseases, it is essential to filter these noises. In this paper we compare performance of Wiener Filtering and Median Filtering methods to filter Additive White Gaussian (AWG) noise with the determined signal to noise ratio (SNR) ranging from 3 to 5 dB applied to long-term ECG recordings samples. Root mean square error (RMSE) and coefficient of determination (R2) between the filtered ECG and original ECG was used as the filter performance indicator. Experimental results show that Wiener filter has better noise filtering performance than Median filter.Keywords: ECG noise filtering, Wiener filtering, median filtering, Gaussian noise, filtering performance
Procedia PDF Downloads 528590 Performance Evaluation of a Piano Key Weir
Authors: M. Shaheer Ali, Talib Mansoor
Abstract:
The Piano Key Weir (PKW) is a particular shape of labyrinth weir, using up- and/or downstream overhangs. The horizontal rectangular labyrinth shape allows to multiply the crest length for a given weir width. With the increasing demand of power, it is becoming greatly essential to increase the storage capacity of existing dams without neglecting their safety. The present aims at comparing the performance of piano key weirs in respect to the normal sharp-crested weirs. The discharge v/s head data for the piano key weir and normal sharp-crested weir obtained from the experimental study were compared and analysed using regression analysis. Piano key weir was found to perform doubly w.r.t a normal weir. The flow profiles show the parabolic nature of flow and the nappe interference in the inlet keys.Keywords: crest length, flow profile, labyrinth weir, normal weir, nappe interference, overhangs, piano key weir
Procedia PDF Downloads 293589 The Origin Variability of the Iliolumbar Artery
Authors: Raid Hommady, Waseem Al-Talalwah, Shorok Al Dorazi, Roger Soames
Abstract:
The iliolumbar artery is a regular branch of posterior division of the internal iliac artery. The present study investigate 82 specimens to identify the origin of iliolumbar artery. The present study targets the sciatic nerve root supply from iliolumbar artery based on its origin and course. In present study, the ililumbar artery arose from the posterior division of internal iliac artery in 52.2%. In few cases, it arose from dorsomedial aspect of the internal iliac artery in 28.8%. In few cases, the iliolumbar artery arose from the dorsal aspects of the internal iliac artery as well as from the common and external iliac artery 1.7%. Also, the iliolumbar artery arose from the sciatic artery as well as from superior and inferior gluteal arteries in 5.1%. Conversely, it found to be congenital absent in 8.5%. Therefore, the posterior trunk of the internal iliac artery is the most common origin of the iliolumbar artery. With the origin variability of the iliolumbar artery, there is a vascular supply variability of the lumbosacral trunk and sacral root of sciatic nerve. The iliolumbar artery provides vascular supply for lumbosacral trunk 57.3% in whereas the sacral root in 5.1%. As a result, surgeons should pay attention to these variations to decrease iatrogenic fault.Keywords: iliolumbar, sciatic artery, internal iliac, external iliac, posterior division
Procedia PDF Downloads 309588 Riding the Crest of the Wave: Inclusive Education in New Zealand
Authors: Barbara A. Perry
Abstract:
In 1996, the New Zealand government and the Ministry of Education announced that they were setting up a "world class system of inclusive education". As a parent of a son with high and complex needs, a teacher, school Principal and Disability studies Lecturer, this author will track the changes in the journey towards inclusive education over the last 20 years. Strategies for partnering with families to ensure educational success along with insights from one of those on the crest of the wave will be presented. Using a narrative methodology the author will illuminate how far New Zealand has come towards this world class system of inclusion promised and share from personal experience some of the highlights and risks in the system. This author has challenged the old structures and been part of the setting up of new structures particularly for providing parent voice and insight; this paper provides a unique view from an insider’s voice as well as a professional in the system.Keywords: disability studies, inclusive education, special education, working with families with children with disability
Procedia PDF Downloads 250587 Multi-Level Pulse Width Modulation to Boost the Power Efficiency of Switching Amplifiers for Analog Signals with Very High Crest Factor
Authors: Jan Doutreloigne
Abstract:
The main goal of this paper is to develop a switching amplifier with optimized power efficiency for analog signals with a very high crest factor such as audio or DSL signals. Theoretical calculations show that a switching amplifier architecture based on multi-level pulse width modulation outperforms all other types of linear or switching amplifiers in that respect. Simulations on a 2 W multi-level switching audio amplifier, designed in a 50 V 0.35 mm IC technology, confirm its superior performance in terms of power efficiency. A real silicon implementation of this audio amplifier design is currently underway to provide experimental validation.Keywords: audio amplifier, multi-level switching amplifier, power efficiency, pulse width modulation, PWM, self-oscillating amplifier
Procedia PDF Downloads 340586 Revisiting Classic Triad of Japanese Spotted Fever: A Case Series of Forty-Three Patients
Authors: Y. Kunitani, Y. Nakashima, S. Yamauchi, Y. Ishigami, K. Naito, K. Numata, M. Mizobe, Y. Homma, J. Takahashi, T. Inoue, T. Shiga, H. Funakoshi
Abstract:
Background: Japanese Spotted Fever (JSF) is one of the Rickettsial infections, caused by Rickettsia japonica, which is transmitted by ticks. JSF is seen in limited area, such as Japan and South Korea. Its clinical triad is rash, eschar and fever. It often shows leukocytopenia, thrombopenia, elevated transaminase and high C-reactive protein (CRP). Sometimes it can be life-threatening due to disseminated intravascular coagulation or multiple organ failure. Study Aim: The aim of this study is to describe the features of JSF, as this unique infection is rapidly growing in Japan. Methods: This is a case series of JSF from 2009 to 2016, in Mie Prefectural Hospital in Japan. We collected JSF cases, which were diagnosed by polymerase chain reaction (PCR) of the skin or blood serum, or the elevation of the antibody titer of paired blood samples. Results: There were 43 JSF patients (19 male, 24 female) with a median age of 71 years [IQR:65-80]. The median body temperature was 38.1°C[IQR: 37.5-39.0]. 95% had a rash, 67% had eschar and 50% had fever. The median WBC count was 6,700 [IQR: 5,750-8,200] and leukocytopenia was observed in only 7%. The median platelet count was 14x104 [IQR10x104-17x104], thrombopenia was observed in 65%. The median aspartate transaminase (AST) was 53 IU/L [IQR: 41-93]; the median alanine aminotransferase (ALT) was 34 IU/L [IQR: 24-54]; the median CRP was 10.4 mg/dL [IQR:7.2-13.9]; the median lactate dehydrogenase (LDH) was 352IU/L [IQR:282-451]. CRP and LDH were elevated in almost all of the patients. Median length of stay in hospital was 8 days [IQR: 6-11]. All patients were treated with tetracycline and quinolone on the day of the presentation. There was no fatality from JSF. Conclusion: The patients with JSF classically presents with eschar, rash and fever. However, in this study, the half of the patients were afebrile. Although JSF is not a common infectious disease worldwide, if the patient had previously visited Japan or South Korea and presented with rash and eschar with or without fever, we should consider JSF as a potential diagnosis.Keywords: infectious disease, Japanese spotted fever, Rickettsial disease, Rickettsia japonica
Procedia PDF Downloads 229585 BeamGA Median: A Hybrid Heuristic Search Approach
Authors: Ghada Badr, Manar Hosny, Nuha Bintayyash, Eman Albilali, Souad Larabi Marie-Sainte
Abstract:
The median problem is significantly applied to derive the most reasonable rearrangement phylogenetic tree for many species. More specifically, the problem is concerned with finding a permutation that minimizes the sum of distances between itself and a set of three signed permutations. Genomes with equal number of genes but different order can be represented as permutations. In this paper, an algorithm, namely BeamGA median, is proposed that combines a heuristic search approach (local beam) as an initialization step to generate a number of solutions, and then a Genetic Algorithm (GA) is applied in order to refine the solutions, aiming to achieve a better median with the smallest possible reversal distance from the three original permutations. In this approach, any genome rearrangement distance can be applied. In this paper, we use the reversal distance. To the best of our knowledge, the proposed approach was not applied before for solving the median problem. Our approach considers true biological evolution scenario by applying the concept of common intervals during the GA optimization process. This allows us to imitate a true biological behavior and enhance genetic approach time convergence. We were able to handle permutations with a large number of genes, within an acceptable time performance and with same or better accuracy as compared to existing algorithms.Keywords: median problem, phylogenetic tree, permutation, genetic algorithm, beam search, genome rearrangement distance
Procedia PDF Downloads 265584 Hybrid Robust Estimation via Median Filter and Wavelet Thresholding with Automatic Boundary Correction
Authors: Alsaidi M. Altaher, Mohd Tahir Ismail
Abstract:
Wavelet thresholding has been a power tool in curve estimation and data analysis. In the presence of outliers this non parametric estimator can not suppress the outliers involved. This study proposes a new two-stage combined method based on the use of the median filter as primary step before applying wavelet thresholding. After suppressing the outliers in a signal through the median filter, the classical wavelet thresholding is then applied for removing the remaining noise. We use automatic boundary corrections; using a low order polynomial model or local polynomial model as a more realistic rule to correct the bias at the boundary region; instead of using the classical assumptions such periodic or symmetric. A simulation experiment has been conducted to evaluate the numerical performance of the proposed method. Results show strong evidences that the proposed method is extremely effective in terms of correcting the boundary bias and eliminating outlier’s sensitivity.Keywords: boundary correction, median filter, simulation, wavelet thresholding
Procedia PDF Downloads 428583 The Origin Variability of the Obturator Artery
Authors: Halimah Al Hifzi, Waseem Al-Talalwah, Shorok Al Dorazi, Hassan Al Mousa, Zainab Al-Hashim, Roger Soames
Abstract:
The obturator artery is one branches of anterior division of the internal iliac artery. It passes on the lateral wall of pelvis to escape into thigh region via obturator foremen. Based on previous research studies, it found to be extremely variable in origin and course. It may arise from internal or external iliac artery. The current study includes 82 dissected specimens to investigate the origin of the obturator artery and explain the clinical importance. The obturator artery arises from the internal iliac artery in 75% either from its anterior or posterior division in 46.9% or 25% respectively. Further, it arises neither from the anterior nor posterior division of the internal iliac artery but it arises between them in 3.1%. In 25%, the obturator artery arises from the external iliac artery. In case of aneurysmectomy of posterior division, carries a high risk of insufficient of vascular supply for demand structures such as proximal adductors attachment and hip joint. Therefore, vascular surgeons have to pay attention to the posterior division being an origin of the obturator artery beside its usual three classical branches: superior gluteal, iliolumbar and lateral sacral arteries. Further, the obturator artery arising from the external iliac system is in great dangerous of laceration in case of anterior pelvic fracture. Therefore, it may lead to haemorrhagic shock threatening life.Keywords: obturator artery, external iliac, internal iliac artery, anterior division, posterior division, superior gluteal, iliolumbar and lateral sacral, pubic fracture, aneurysm, shock
Procedia PDF Downloads 356