1556 Investigation of Ignition Delay for Low Molecular Hydrocarbon Fuel and Oxygen Mixture behind the Reflected Shock

Authors: K. R. Guna, Aldin Justin Sundararaj, B. C. Pillai, A. N. Subash

Abstract:

A systematic study has been made for ignition delay times measurement behind a reflected shock wave for the low molecular weight hydrocarbon fuel in argon simulated gas mixtures. The low molecular hydrocarbon fuel–oxygen was diluted with argon for desired concentration is taken for the study. The suitability of the shock tube for measuring the ignition delay time is demonstrated by measuring the ignition delay for the liquefied petroleum gas for equivalence ratios (ф=0.5 & 1) in the temperature range 1150-1650 K. The pressure range was fixed from 5-15 bar. The ignition delay was measured by recording the ignition-induced pressure jump and emission from CH radical simultaneously. From conducting experiments, it was found that the ignition delay time for liquefied petroleum gas reduces with increase in temperature. The shock tube was calibrated for ethane-oxygen gas mixture and the results obtained from this study is compared with the earlier reported values and found to be comparably well suited for the measurement of ignition delay times. The above work was carried out using the shock tube facility at propulsion and high enthalpy laboratory, Karunya University.

Keywords: ignition delay, LPG, reflected shock, shock wave

Procedia PDF Downloads 229
1555 The Effectiveness of Electronic Local Financial Management Information System (ELFMIS) in Mempawah Regency, West Borneo Province, Indonesia

Authors: Muhadam Labolo, Afdal R. Anwar, Sucia Miranti Sipisang

Abstract:

Electronic Local Finance Management Information System (ELFMIS) is integrated application that was used as a tool for local governments to improve the effectiveness of the implementation of the various areas of financial management regulations. Appropriate With Exceptions Opinion (WDP) of Indonesia Audit Agency (BPK) for local governments Mempawah is a financial management problem that must be improved to avoid mistakes in decision-making. The use of Electronic Local Finance Management Information System (ELFMIS) by Mempawah authority has not yet performed maximally. These problems became the basis for research in measuring the effectiveness LFMIS in Mempawah regency. This research uses an indicator variable for measuring information systems effectiveness proposed by Bodnar. This research made use descriptive with inductive approach. Data collection techniques were mixed from qualitative and quantitative techniques, used questionnaires, interviews and documentation. The obstacles in Local Finance Board (LFB) for the application of ELFMIS such as connection, the quality and quantity of human resources, realization of financial resources, absence of maintenance and another facilities of ELFMIS and verification for financial information.

Keywords: effectiveness, E-LFMIS, finance, local government, system

Procedia PDF Downloads 192
1554 Multilayer Ceramic Capacitors: Based Force Sensor Array for Occlusal Force Measurement

Authors: Sheng-Che Chen, Keng-Ren Lin, Che-Hsin Lin, Hao-Yuan Tseng, Chih-Han Chang

Abstract:

Teeth play an important role in providing the essential nutrients. The force loading of chewing on the crow is important condition to evaluate long-term success of many dental treatments. However, the quantification of the force regarding forces are distributed over the dental crow is still not well recognized. This study presents an industrial-grade piezoelectric-based multilayer ceramic capacitors (MLCCs) force sensor for measuring the distribution of the force distribute over the first molar. The developed sensor array is based on a flexible polyimide electrode and barium titanate-based MLCCs. MLCCs are commonly used in the electronic industry and it is a typical electric component composed of BaTiO₃, which is used as a capacitive material. The most important is that it also can be used as a force-sensing component by its piezoelectric property. In this study, to increase the sensitivity as well as to reduce the variation of different MLCCs, a treatment process is utilized. The MLCC force sensors are able to measure large forces (above 500 N), making them suitable for measuring the bite forces on the tooth crown. Moreover, the sensors also show good force response and good repeatability.

Keywords: force sensor array, multilayer ceramic capacitors, occlusal force, piezoelectric

Procedia PDF Downloads 387
1553 Inter Laboratory Comparison with Coordinate Measuring Machine and Uncertainty Analysis

Authors: Tugrul Torun, Ihsan A. Yuksel, Si̇nem On Aktan, Taha K. Vezi̇roglu

Abstract:

In the quality control processes in some industries, the usage of CMM has increased in recent years. Consequently, the CMMs play important roles in the acceptance or rejection of manufactured parts. For parts, it’s important to be able to make decisions by performing fast measurements. According to related technical drawing and its tolerances, measurement uncertainty should also be considered during assessment. Since uncertainty calculation is difficult and time-consuming, most companies ignore the uncertainty value in their routine inspection method. Although studies on measurement uncertainty have been carried out on CMM’s in recent years, there is still no applicable method for analyzing task-specific measurement uncertainty. There are some standard series for calculating measurement uncertainty (ISO-15530); it is not possible to use it in industrial measurement because it is not a practical method for standard measurement routine. In this study, the inter-laboratory comparison test has been carried out in the ROKETSAN A.Ş. with all dimensional inspection units. The reference part that we used is traceable to the national metrology institute TUBİTAK UME. Each unit has measured reference parts according to related technical drawings, and the task-specific measuring uncertainty has been calculated with related parameters. According to measurement results and uncertainty values, the En values have been calculated.

Keywords: coordinate measurement, CMM, comparison, uncertainty

Procedia PDF Downloads 173
1552 Framework to Quantify Customer Experience

Authors: Anant Sharma, Ashwin Rajan

Abstract:

Customer experience is measured today based on defining a set of metrics and KPIs, setting up thresholds and defining triggers across those thresholds. While this is an effective way of measuring against a Key Performance Indicator ( referred to as KPI in the rest of the paper ), this approach cannot capture the various nuances that make up the overall customer experience. Customers consume a product or service at various levels, which is not reflected in metrics like Customer Satisfaction or Net Promoter Score, but also across other measurements like recurring revenue, frequency of service usage, e-learning and depth of usage. Here we explore an alternative method of measuring customer experience by flipping the traditional views. Rather than rolling customers up to a metric, we roll up metrics to hierarchies and then measure customer experience. This method allows any team to quantify customer experience across multiple touchpoints in a customer’s journey. We make use of various data sources which contain information for metrics like CXSAT, NPS, Renewals, and depths of service usage collected across a customer lifecycle. This data can be mined systematically to get linkages between different data points like geographies, business groups, products and time. Additional views can be generated by blending synthetic contexts into the data to show trends and top/bottom types of reports. We have created a framework that allows us to measure customer experience using the above logic.

Keywords: analytics, customers experience, BI, business operations, KPIs, metrics

Procedia PDF Downloads 41
1551 Prediction Model of Body Mass Index of Young Adult Students of Public Health Faculty of University of Indonesia

Authors: Yuwaratu Syafira, Wahyu K. Y. Putra, Kusharisupeni Djokosujono

Abstract:

Background/Objective: Body Mass Index (BMI) serves various purposes, including measuring the prevalence of obesity in a population, and also in formulating a patient’s diet at a hospital, and can be calculated with the equation = body weight (kg)/body height (m)². However, the BMI of an individual with difficulties in carrying their weight or standing up straight can not necessarily be measured. The aim of this study was to form a prediction model for the BMI of young adult students of Public Health Faculty of University of Indonesia. Subject/Method: This study used a cross sectional design, with a total sample of 132 respondents, consisted of 58 males and 74 females aged 21- 30. The dependent variable of this study was BMI, and the independent variables consisted of sex and anthropometric measurements, which included ulna length, arm length, tibia length, knee height, mid-upper arm circumference, and calf circumference. Anthropometric information was measured and recorded in a single sitting. Simple and multiple linear regression analysis were used to create the prediction equation for BMI. Results: The male respondents had an average BMI of 24.63 kg/m² and the female respondents had an average of 22.52 kg/m². A total of 17 variables were analysed for its correlation with BMI. Bivariate analysis showed the variable with the strongest correlation with BMI was Mid-Upper Arm Circumference/√Ulna Length (MUAC/√UL) (r = 0.926 for males and r = 0.886 for females). Furthermore, MUAC alone also has a very strong correlation with BMI (r = 0,913 for males and r = 0,877 for females). Prediction models formed from either MUAC/√UL or MUAC alone both produce highly accurate predictions of BMI. However, measuring MUAC/√UL is considered inconvenient, which may cause difficulties when applied on the field. Conclusion: The prediction model considered most ideal to estimate BMI is: Male BMI (kg/m²) = 1.109(MUAC (cm)) – 9.202 and Female BMI (kg/m²) = 0.236 + 0.825(MUAC (cm)), based on its high accuracy levels and the convenience of measuring MUAC on the field.

Keywords: body mass index, mid-upper arm circumference, prediction model, ulna length

Procedia PDF Downloads 191
1550 Development of Colorimetric Based Microfluidic Platform for Quantification of Fluid Contaminants

Authors: Sangeeta Palekar, Mahima Rana, Jayu Kalambe

Abstract:

In this paper, a microfluidic-based platform for the quantification of contaminants in the water is proposed. The proposed system uses microfluidic channels with an embedded environment for contaminants detection in water. Microfluidics-based platforms present an evident stage of innovation for fluid analysis, with different applications advancing minimal efforts and simplicity of fabrication. Polydimethylsiloxane (PDMS)-based microfluidics channel is fabricated using a soft lithography technique. Vertical and horizontal connections for fluid dispensing with the microfluidic channel are explored. The principle of colorimetry, which incorporates the use of Griess reagent for the detection of nitrite, has been adopted. Nitrite has high water solubility and water retention, due to which it has a greater potential to stay in groundwater, endangering aquatic life along with human health, hence taken as a case study in this work. The developed platform also compares the detection methodology, containing photodetectors for measuring absorbance and image sensors for measuring color change for quantification of contaminants like nitrite in water. The utilization of image processing techniques offers the advantage of operational flexibility, as the same system can be used to identify other contaminants present in water by introducing minor software changes.

Keywords: colorimetric, fluid contaminants, nitrite detection, microfluidics

Procedia PDF Downloads 172
1549 A Development of Portable Intrinsically Safe Explosion-Proof Type of Dual Gas Detector

Authors: Sangguk Ahn, Youngyu Kim, Jaheon Gu, Gyoutae Park

Abstract:

In this paper, we developed a dual gas leak instrument to detect Hydrocarbon (HC) and Monoxide (CO) gases. To two kinds of gases, it is necessary to design compact structure for sensors. And then it is important to draw sensing circuits such as measuring, amplifying and filtering. After that, it should be well programmed with robust, systematic and module coding methods. In center of them, improvement of accuracy and initial response time are a matter of vital importance. To manufacture distinguished gas leak detector, we applied intrinsically safe explosion-proof structure to lithium ion battery, main circuits, a pump with motor, color LCD interfaces and sensing circuits. On software, to enhance measuring accuracy we used numerical analysis such as Lagrange and Neville interpolation. Performance test result is conducted by using standard Methane with seven different concentrations with three other products. We want raise risk prevention and efficiency of gas safe management through distributing to the field of gas safety. Acknowledgment: This study was supported by Small and Medium Business Administration under the research theme of ‘Commercialized Development of a portable intrinsically safe explosion-proof type dual gas leak detector’, (task number S2456036).

Keywords: gas leak, dual gas detector, intrinsically safe, explosion proof

Procedia PDF Downloads 208
1548 Adaptation and Validation of the Program Sustainability Assessment Tool

Authors: Henok Metaferia Gebremariam

Abstract:

Worldwide, considerable resources are spent implementing public health interventions that are interrupted soon after the initial funding ends. However, ambiguity remains as to how health programs can be effectively sustained over time because of the diversity of perspectives, definitions, study methods, outcomes measures and timeframes. From all the above-mentioned research challenges, standardized measures of sustainability should ultimately become a key research issue. To resolve this key challenge, the objective of the study was to adapt a tool for measuring the program’s capacity for sustainability and evaluating its reliability and validity. To adapt and validate the tool, a cross-sectional and cohort study design was conducted at 26 programs in Addis Ababa between September 2014 and May 2015. An adapted version of the tool after the pilot test was administered to 220 staff. The tool was analyzed for reliability and validity. Results show that a 40-item PSAT tool had been adapted into the Amharic version with good internal consistency (Cronbach’s alpha= 0.80), test-retest reliability(r=0.916) and construct validity. Factor analysis resulted in 7 components explaining 56.67 % of the variance. In conclusion, it was found that the Amharic version of PAST was a reliable and valid tool for measuring the program’s capacity for sustainability.

Keywords: program sustainability, public health interventions, reliability, validity

Procedia PDF Downloads 4
1547 Measuring and Evaluating the Effectiveness of Mobile High Efficiency Particulate Air Filtering on Particulate Matter within the Road Traffic Network of a Sample of Non-Sparse and Sparse Urban Environments in the UK

Authors: Richard Maguire

Abstract:

This research evaluates the efficiency of using mobile HEPA filters to reduce localized Particulate Matter (PM), Total Volatile Organic Chemical (TVOC) and Formaldehyde (HCHO) Air Pollution. The research is being performed using a standard HEPA filter that is tube fitted and attached to a motor vehicle. The velocity of the vehicle is used to generate the pressure difference that allows the filter to remove PM, VOC and HCOC pollution from the localized atmosphere of a road transport traffic route. The testing has been performed on a sample of traffic routes in Non-Sparse and Sparse urban environments within the UK. Pre and Post filter measuring of the PM2.5 Air Quality has been carried out along with demographics of the climate environment, including live filming of the traffic conditions. This provides a base line for future national and international research. The effectiveness measurement is generated through evaluating the difference in PM2.5 Air Quality measured pre- and post- the mobile filter test equipment. A series of further research opportunities and future exploitation options are made based on the results of the research.

Keywords: high efficiency particulate air, HEPA filter, particulate matter, traffic pollution

Procedia PDF Downloads 95
1546 Opportunity Integrated Assessment Facilitating Critical Thinking and Science Process Skills Measurement on Acid Base Matter

Authors: Anggi Ristiyana Puspita Sari, Suyanta

Abstract:

To recognize the importance of the development of critical thinking and science process skills, the instrument should give attention to the characteristics of chemistry. Therefore, constructing an accurate instrument for measuring those skills is important. However, the integrated instrument assessment is limited in number. The purpose of this study is to validate an integrated assessment instrument for measuring students’ critical thinking and science process skills on acid base matter. The development model of the test instrument adapted McIntire model. The sample consisted of 392 second grade high school students in the academic year of 2015/2016 in Yogyakarta. Exploratory factor analysis (EFA) was conducted to explore construct validity, whereas content validity was substantiated by Aiken’s formula. The result shows that the KMO test is 0.714 which indicates sufficient items for each factor and the Bartlett test is significant (a significance value of less than 0.05). Furthermore, content validity coefficient which is based on 8 expert judgments is obtained at 0.85. The findings support the integrated assessment instrument to measure critical thinking and science process skills on acid base matter.

Keywords: acid base matter, critical thinking skills, integrated assessment instrument, science process skills, validity

Procedia PDF Downloads 295
1545 Blood Oxygen Saturation Measurement System Using Broad-Band Light Source with LabVIEW Program

Authors: Myoung Ah Kim, Dong Ho Sin, Chul Gyu Song

Abstract:

Blood oxygen saturation system is a well-established, noninvasive photoplethysmographic method to monitor vital signs. Conventional blood oxygen saturation measurements for the two LED light source is the ambiguity of the oxygen saturation measurement principle and the measurement results greatly influenced and heat and motion artifact. A high accuracy in order to solve these problems blood oxygen saturation measuring method has been proposed using a broadband light source that can be easily understood by the algorithm. The measurement of blood oxygen saturation based on broad-band light source has advantage of simple testing facility and easy understanding. Broadband light source based on blood oxygen saturation measuring program proposed in this paper is a combination of LabVIEW and MATLAB. Using the wavelength range of 450 nm-750 nm using a floating light absorption of oxyhemoglobin and deoxyhemoglobin to measure the blood oxygen saturation. Hand movement is to fix the probe to the motor stage in order to prevent oxygen saturation measurement that affect the sample and probe kept constant interval. Experimental results show that the proposed method noticeably increases the accuracy and saves time compared with the conventional methods.

Keywords: oxygen saturation, broad-band light source, CCD, light reflectance theory

Procedia PDF Downloads 417
1544 Analytical Formulae for the Approach Velocity Head Coefficient

Authors: Abdulrahman Abdulrahman

Abstract:

Critical depth meters, such as abroad crested weir, Venture Flume and combined control flume are standard devices for measuring flow in open channels. The discharge relation for these devices cannot be solved directly, but it needs iteration process to account for the approach velocity head. In this paper, analytical solution was developed to calculate the discharge in a combined critical depth-meter namely, a hump combined with lateral contraction in rectangular channel with subcritical approach flow including energy losses. Also analytical formulae were derived for approach velocity head coefficient for different types of critical depth meters. The solution was derived by solving a standard cubic equation considering energy loss on the base of trigonometric identity. The advantage of this technique is to avoid iteration process adopted in measuring flow by these devices. Numerical examples are chosen for demonstration of the proposed solution.

Keywords: broad crested weir, combined control meter, control structures, critical flow, discharge measurement, flow control, hydraulic engineering, hydraulic structures, open channel flow

Procedia PDF Downloads 247
1543 Effects of Paroxetine on Biochemical Parameters and Reproductive Function in Male Rats

Authors: Rachid Mosbah, Aziez Chettoum, Zouhir Djerrou, Alberto Mantovani

Abstract:

Selective serotonin reuptake inhibitors (SSRI) are a class of molecules used in treating depression, anxiety, and mood disorders. Paroxetine (PRT) is one of the mostly prescribed antidepressant which has attracted great attention regarding its side effects in recent years. This study was planned to assess the adverse effects of PRT on the biochemical parameters and reproductive system. Fourteen male Wistar rats were randomly allocated into two groups (7 rats or each): control and treated with PRT at dose of 5mg/kg.bw for two weeks. At the end of the experiment, blood was collected from retro orbital plexus for measuring the biochemical parameters, whereas the reproductive organs were removed for measuring semen quality and the histological investigations. Results showed that PRT induced significant changes in some biochemical parameters and alteration of semen quality including sperm count, spermatids number and sperm viability, motility, and abnormalities. The histopathological examinations of testis and epididymis revealed an alteration of spermatogenesis, cellular disorganization and vacuolization, enlargement of interstitial space, shrinkage and degenerative changes in the epithelium of seminiferous and epididymal tubules with few to nil numbers of spermatozoa in their lumen. In conclusion, PRT treatment caused changes in some biochemical parameters and sperm profile as well as histopathologic effects of reproductive organs.

Keywords: antidepressant, biochemical parameters, reproductive function, paroxetine

Procedia PDF Downloads 96
1542 A Relational View for Financial Metrics in Logistics Service Providers

Authors: Paulo Sergio Altman Ferreira

Abstract:

Relationship development plays an essential role in every logistics company. Logistics companies are service-based businesses essentially performing the flow of materials, housing, and inventory management for a wide range of customers. The service encounter between the logistics provider’s personnel and the customers may form a connection that will demonstrate a strong impact, not only to the customers' overall satisfaction but may also provide the perception of individualized services. Logistics services must drive value. It also shows a close influence on the quality and costs of client-centered services. If we describe logistics value creation as the function of quality perception of the client divided by service costs, there is a requirement to better outline and explain the measures and analytics for logistics costs and relationship performance. This critical shift to understand logistics services is a relevant contribution to capture how relationship value can be quantified. This might involve changing our current perspective on logistics providers beyond uniquely measuring the services in terms of activities, personnel levels, and financial/costs ratios. This paper argues that measuring value creation accomplishments of logistics services needs to consider the relational improvements for the wider range of logistics companies. Accurate logistics value requires a description of the financial impact of the relational perspective of the service.

Keywords: logistics services providers, financial metrics, relationship management, value creation

Procedia PDF Downloads 120
1541 Study on the Non-Contact Sheet Resistance Measuring of Silver Nanowire Coated Film Using Terahertz Wave

Authors: Dong-Hyun Kim, Wan-Ho Chung, Hak-Sung Kim

Abstract:

In this work, non-destructive evaluation was conducted to measure the sheet resistance of silver nanowire coated film and find a damage of that film using terahertz (THz) wave. Pulse type THz instrument was used, and the measurement was performed under transmission and pitch-catch reflection modes with 30 degree of incidence angle. In the transmission mode, the intensity of the THz wave was gradually increased as the conductivity decreased. Meanwhile, the intensity of THz wave was decreased as the conductivity decreased in the pitch-catch reflection mode. To confirm the conductivity of the film, sheet resistance was measured by 4-point probe station. Interaction formula was drawn from a relation between the intensity and the sheet resistance. Through substituting sheet resistance to the formula and comparing the resultant value with measured maximum THz wave intensity, measurement of sheet resistance using THz wave was more suitable than that using 4-point probe station. In addition, the damage on the silver nanowire coated film was detected by applying the THz image system. Therefore, the reliability of the entire film can be also be ensured. In conclusion, real-time monitoring using the THz wave can be applied in the transparent electrodes with detecting the damaged area as well as measuring the sheet resistance.

Keywords: terahertz wave, sheet resistance, non-destructive evaluation, silver nanowire

Procedia PDF Downloads 464
1540 Design and Fabrication of a Programmable Stiffness-Sensitive Gripper for Object Handling

Authors: Mehdi Modabberifar, Sanaz Jabary, Mojtaba Ghodsi

Abstract:

Stiffness sensing is an important issue in medical diagnostic, robotics surgery, safe handling, and safe grasping of objects in production lines. Detecting and obtaining the characteristics in dwelling lumps embedded in a soft tissue and safe removing and handling of detected lumps is needed in surgery. Also in industry, grasping and handling an object without damaging in a place where it is not possible to access a human operator is very important. In this paper, a method for object handling is presented. It is based on the use of an intelligent gripper to detect the object stiffness and then setting a programmable force for grasping the object to move it. The main components of this system includes sensors (sensors for measuring force and displacement), electrical (electrical and electronic circuits, tactile data processing and force control system), mechanical (gripper mechanism and driving system for the gripper) and the display unit. The system uses a rotary potentiometer for measuring gripper displacement. A microcontroller using the feedback received by the load cell, mounted on the finger of the gripper, calculates the amount of stiffness, and then commands the gripper motor to apply a certain force on the object. Results of Experiments on some samples with different stiffness show that the gripper works successfully. The gripper can be used in haptic interfaces or robotic systems used for object handling.

Keywords: gripper, haptic, stiffness, robotic

Procedia PDF Downloads 329
1539 Enhanced Calibration Map for a Four-Hole Probe for Measuring High Flow Angles

Authors: Jafar Mortadha, Imran Qureshi

Abstract:

This research explains and compares the modern techniques used for measuring the flow angles of a flowing fluid with the traditional technique of using multi-hole pressure probes. In particular, the focus of the study is on four-hole probes, which offer great reliability and benefits in several applications where the use of modern measurement techniques is either inconvenient or impractical. Due to modern advancements in manufacturing, small multi-hole pressure probes can be made with high precision, which eliminates the need for calibrating every manufactured probe. This study aims to improve the range of calibration maps for a four-hole probe to allow high flow angles to be measured accurately. The research methodology comprises a literature review of the successful calibration definitions that have been implemented on five-hole probes. These definitions are then adapted and applied on a four-hole probe using a set of raw pressures data. A comparison of the different definitions will be carried out in Matlab and the results will be analyzed to determine the best calibration definition. Taking simplicity of implementation into account as well as the reliability of flow angles estimation, an adapted technique from a research paper written in 2002 offered the most promising outcome. Consequently, the method is seen as a good enhancement for four-hole probes and it can substitute for the existing calibration definitions that offer less accuracy.

Keywords: calibration definitions, calibration maps, flow measurement techniques, four-hole probes, multi-hole pressure probes

Procedia PDF Downloads 266
1538 A Non-Invasive Neonatal Jaundice Screening Device Measuring Bilirubin on Eyes

Authors: Li Shihao, Dieter Trau

Abstract:

Bilirubin is a yellow substance that is made when the body breaks down old red blood cells. High levels of bilirubin can cause jaundice, a condition that makes the newborn's skin and the white part of the eyes look yellow. Jaundice is a serial-killer in developing countries in Southeast Asia such as Myanmar and most parts of Africa where jaundice screening is largely unavailable. Worldwide, 60% of newborns experience infant jaundice. One in ten will require therapy to prevent serious complications and lifelong neurologic sequelae. Limitations of current solutions: - Blood test: Blood tests are painful may largely unavailable in poor areas of developing countries, and also can be costly and unsafe due to the insufficient investment and lack of access to health care systems. - Transcutaneous jaundice-meter: 1) can only provide reliable results to caucasian newborns, due to skin pigmentations since current technologies measure bilirubin by the color of the skin. Basically, the darker the skin is, the harder to measure, 2) current jaundice meters are not affordable for most underdeveloped areas in Africa like Kenya and Togo, 3) fat tissue under the skin also influences the accuracy, which will give overestimated results, 4) current jaundice meters are not reliable after treatment (phototherapy) because bilirubin levels underneath the skin will be reduced first, while overall levels may be quite high. Thus, there is an urgent need for a low-cost non-invasive device, which can be effective not only for caucasian babies but also Asian and African newborns, to save lives at the most vulnerable time and prevent any complications like brain damage. Instead of measuring bilirubin on skin, we proposed a new method to do the measurement on the sclera, which can avoid the difference of skin pigmentations and ethnicities, due to the necessity for the sclera to be white regardless of racial background. This is a novel approach for measuring bilirubin by an optical method of light reflection off the white part of the eye. Moreover, the device is connected to a smart device, which can provide a user-friendly interface and the ability to record the clinical data continuously A disposable eye cap will be provided avoiding contamination and fixing the distance to the eye.

Keywords: Jaundice, bilirubin, non-invasive, sclera

Procedia PDF Downloads 213
1537 The Design and Implementation of a Calorimeter for Evaluation of the Thermal Performance of Materials: The Case of Phase Change Materials

Authors: Ebrahim Solgi, Zahra Hamedani, Behrouz Mohammad Kari, Ruwan Fernando, Henry Skates

Abstract:

The use of thermal energy storage (TES) as part of a passive design strategy can reduce a building’s energy demand. TES materials do this by increasing the lag between energy consumption and energy supply by absorbing, storing and releasing energy in a controlled manner. The increase of lightweight construction in the building industry has made it harder to utilize thermal mass. Consequently, Phase Change Materials (PCMs) are a promising alternative as they can be manufactured in thin layers and used with lightweight construction to store latent heat. This research investigates utilizing PCMs, with the first step being measuring their performance under experimental conditions. To do this requires three components. The first is a calorimeter for measuring indoor thermal conditions, the second is a pyranometer for recording the solar conditions: global, diffuse and direct radiation and the third is a data-logger for recording temperature and humidity for the studied period. This paper reports on the design and implementation of an experimental setup used to measure the thermal characteristics of PCMs as part of a wall construction. The experimental model has been simulated with the software EnergyPlus to create a reliable simulation model that warrants further investigation.

Keywords: phase change materials, EnergyPlus, experimental evaluation, night ventilation

Procedia PDF Downloads 226
1536 Study of Human Upper Arm Girth during Elbow Isokinetic Contractions Based on a Smart Circumferential Measuring System

Authors: Xi Wang, Xiaoming Tao, Raymond C. H. So

Abstract:

As one of the convenient and noninvasive sensing approaches, the automatic limb girth measurement has been applied to detect intention behind human motion from muscle deformation. The sensing validity has been elaborated by preliminary researches but still need more fundamental study, especially on kinetic contraction modes. Based on the novel fabric strain sensors, a soft and smart limb girth measurement system was developed by the authors’ group, which can measure the limb girth in-motion. Experiments were carried out on elbow isometric flexion and elbow isokinetic flexion (biceps’ isokinetic contractions) of 90°/s, 60°/s, and 120°/s for 10 subjects (2 canoeists and 8 ordinary people). After removal of natural circumferential increments due to elbow position, the joint torque is found not uniformly sensitive to the limb circumferential strains, but declining as elbow joint angle rises, regardless of the angular speed. Moreover, the maximum joint torque was found as an exponential function of the joint’s angular speed. This research highly contributes to the application of the automatic limb girth measuring during kinetic contractions, and it is useful to predict the contraction level of voluntary skeletal muscles.

Keywords: fabric strain sensor, muscle deformation, isokinetic contraction, joint torque, limb girth strain

Procedia PDF Downloads 302
1535 Measurement of Turbulence with PITOT Static Tube in Low Speed Subsonic Wind Tunnel

Authors: Gopikrishnan, Bharathiraja, Boopalan, Jensin Joshua

Abstract:

The Pitot static tube has proven their values and practicability in measuring velocity of fluids for many years. With the aim of extensive usage of such Pitot tube systems, one of the major enabling technologies is to use the design and fabricate a high sensitive pitot tube for the purpose of calibration of the subsonic wind tunnel. Calibration of wind tunnel is carried out by using different instruments to measure variety of parameters. Using too many instruments inside the tunnel may not only affect the fluid flow but also lead to drag or losses. So, it is essential to replace the different system with a single system that would give all the required information. This model of high sensitive Pitot tube has been designed to ease the calibration process. It minimizes the use of different instruments and this single system is capable of calibrating the wind tunnel test section. This Pitot static tube is completely digitalized and so that the velocity data`s can be collected directly from the instrument. Since the turbulence factors are dependent on velocity, the data’s that are collected from the pitot static tube are then processed and the level of turbulence in the fluid flow is calculated. It is also capable of measuring the pressure distribution inside the wind tunnel and the flow angularity of the fluid. Thus, the well-designed high sensitive Pitot static tube is utilized in calibrating the tunnel and also for the measurement of turbulence.

Keywords: pitot static tube, turbulence, wind tunnel, velocity

Procedia PDF Downloads 498
1534 A POX Controller Module to Collect Web Traffic Statistics in SDN Environment

Authors: Wisam H. Muragaa, Kamaruzzaman Seman, Mohd Fadzli Marhusin

Abstract:

Software Defined Networking (SDN) is a new norm of networks. It is designed to facilitate the way of managing, measuring, debugging and controlling the network dynamically, and to make it suitable for the modern applications. Generally, measurement methods can be divided into two categories: Active and passive methods. Active measurement method is employed to inject test packets into the network in order to monitor their behaviour (ping tool as an example). Meanwhile the passive measurement method is used to monitor the traffic for the purpose of deriving measurement values. The measurement methods, both active and passive, are useful for the collection of traffic statistics, and monitoring of the network traffic. Although there has been a work focusing on measuring traffic statistics in SDN environment, it was only meant for measuring packets and bytes rates for non-web traffic. In this study, a feasible method will be designed to measure the number of packets and bytes in a certain time, and facilitate obtaining statistics for both web traffic and non-web traffic. Web traffic refers to HTTP requests that use application layer; while non-web traffic refers to ICMP and TCP requests. Thus, this work is going to be more comprehensive than previous works. With a developed module on POX OpenFlow controller, information will be collected from each active flow in the OpenFlow switch, and presented on Command Line Interface (CLI) and wireshark interface. Obviously, statistics that will be displayed on CLI and on wireshark interfaces include type of protocol, number of bytes and number of packets, among others. Besides, this module will show the number of flows added to the switch whenever traffic is generated from and to hosts in the same statistics list. In order to carry out this work effectively, our Python module will send a statistics request message to the switch requesting its current ports and flows statistics in every five seconds; while the switch will reply with the required information in a message called statistics reply message. Thus, POX controller will be notified and updated with any changes could happen in the entire network in a very short time. Therefore, our aim of this study is to prepare a list for the important statistics elements that are collected from the whole network, to be used for any further researches; particularly, those that are dealing with the detection of the network attacks that cause a sudden rise in the number of packets and bytes like Distributed Denial of Service (DDoS).

Keywords: mininet, OpenFlow, POX controller, SDN

Procedia PDF Downloads 196
1533 Variables for Measuring the Impact of the Social Enterprises in the Field of Community Development

Authors: A. Irudaya Veni Mary, M. Victor Louis Anthuvan, P. Christie, A. Indira

Abstract:

In India, social enterprises are working to create social value in various fields including education; health; women and child development; environment protection and community development. Although social enterprises have brought about tremendous changes in the lives of beneficiaries, the importance of their works is not understood thoroughly. One of the ways to prove themselves is to measure the impact, which in recent times has received much attention. This paper focuses on the study of social value created by the social enterprises in the field of community development. It also aims to put forth a research tool for measuring the social value created by the social enterprises in the field of community development. A close-ended interview schedule was prepared to measure the social value creation and it was administered among 60 beneficiaries of two social enterprises who work in the field of community development. The study results show that the social enterprises have brought four types of impact in the life of their beneficiaries; economic impact, social impact, political impact and cultural impact. This study is limited to the social enterprises those who work towards community development. This empirical finding will enable the reader to understand various types of social value created by the social enterprises working in the field of community development. This study will also serve as guide for social enterprises in community development activities to measure their impact and thereby improve their operation towards the betterment of the society. This paper is derived from an empirical research carried out to describe the different types of social value created by the social enterprises in India.

Keywords: social enterprise, social entrepreneurs, social impact, social value, tool for social impact measurement

Procedia PDF Downloads 246
1532 Expression of Metallothionein Gen and Protein on Hepatopancreas, Gill and Muscle of Perna viridis Caused by Biotoxicity Hg, Pb and Cd

Authors: Yulia Irnidayanti , J. J. Josua, A. Sugianto

Abstract:

Jakarta Bay with 13 rivers that flow into, the environment has deteriorated and is the most polluted bays in Asia. The entry of waste into the waters of the Bay of Jakarta has caused pollution. Heavy metal contamination has led to pollution levels and may cause toxicity to organisms that live in the sea, down to the cellular level and may affect the ecological balance. Various ways have been conducted to measure the impact of environmental degradation, such as by measuring the levels of contaminants in the environment, including measuring the accumulation of toxic compounds in the tissues of organisms. Biological responses or biomarkers known as a sensitive indicator but need relevant predictions. In heavy metal pollution monitoring, analysis of aquatic biota is very important from the analysis of the water itself. The content of metals in aquatic biota will usually always be increased from time to time due to the nature of metal bioaccumulation, so the aquatic biota is best used as an indicator of metal pollution in aquatic environments. The results of the content analysis results of sea water in coastal estuaries Angke, Kaliadem and Panimbang detected heavy metals cadmium, mercury, lead, but did not find zinc metal. Based on the results of protein electrophoresis methallotionein found heavy metals in the tissues hepatopancreas, gills and muscles, and also the mRNA expression of has detected.

Keywords: gills, heavy metal, hepatopancreas, metallothionein, muscle

Procedia PDF Downloads 365
1531 Response Delay Model: Bridging the Gap in Urban Fire Disaster Response System

Authors: Sulaiman Yunus

Abstract:

The need for modeling response to urban fire disaster cannot be over emphasized, as recurrent fire outbreaks have gutted most cities of the world. This necessitated the need for a prompt and efficient response system in order to mitigate the impact of the disaster. Promptness, as a function of time, is seen to be the fundamental determinant for efficiency of a response system and magnitude of a fire disaster. Delay, as a result of several factors, is one of the major determinants of promptgness of a response system and also the magnitude of a fire disaster. Response Delay Model (RDM) intends to bridge the gap in urban fire disaster response system through incorporating and synchronizing the delay moments in measuring the overall efficiency of a response system and determining the magnitude of a fire disaster. The model identified two delay moments (pre-notification and Intra-reflex sequence delay) that can be elastic and collectively plays a significant role in influencing the efficiency of a response system. Due to variation in the elasticity of the delay moments, the model provides for measuring the length of delays in order to arrive at a standard average delay moment for different parts of the world, putting into consideration geographic location, level of preparedness and awareness, technological advancement, socio-economic and environmental factors. It is recommended that participatory researches should be embarked on locally and globally to determine standard average delay moments within each phase of the system so as to enable determining the efficiency of response systems and predicting fire disaster magnitudes.

Keywords: delay moment, fire disaster, reflex sequence, response, response delay moment

Procedia PDF Downloads 179
1530 Double Beta Decay Experiments in Novi Sad

Authors: Nataša Todorović, Jovana Nikolov

Abstract:

Despite the great interest in β⁻β⁻ decay, β⁺β⁺ decays are rarely investigated due to the low probability of detecting these processes with available low-level equipment. If β⁺β⁺, β⁺EC, or ECEC decay occurs in a thin sample of a material, the positrons will be stopped and annihilated inside the material, leading to the emission of two or four coincidence gamma photons energy of 511 keV. The paper presents the results of measurements of double beta decay of ⁶⁴Zn, ⁵⁰Cr, and ⁵⁴Fe isotopes. In the first experiment, 511-keV gamma rays originating from the annihilation of positrons in natural zinc were measured by a coincidence technique to obtain a non-zero value for the (0ν+2ν) half-life. In the second experiment, the result of measuring double beta decay of ⁵⁰Cr is presented, which suggests a result other than zero at 95% CL and gives the lowest limit for the half-life of this process. In the third experiment, neutrino-less ECEC decay of ⁵⁴Fe was examined. Under the decay theory, gamma rays are emitted whose energy does not coincide with the energies of gamma rays emitted by nuclei from known discrete excited states. Iron shield of an internal volume of 1 m³ and thickness of 25 cm served as a source for measuring the (0ν+2ν) process in ⁵⁴Fe, whose yield in natural iron is 5.4%. We obtain the lower limit for the half-life for ⁵⁴Fe: T(0ν, K, K)>4.4x10²⁰ yr, T(0ν, K, L)>4.1x10²⁰ yr, and T(0ν, L, L)>5.0x10²⁰ yr. For ⁵⁰Cr limit for the half-life is T(0ν+2ν)>1.3(6)x10¹⁸ yr, and for ⁶⁴Zn T(0ν+2ν, ECβ+)=1.1(0.9)x10⁹ years.

Keywords: neutrinoless double beta decay, half-life, ⁶⁴Zn, ⁵⁰Cr, and, ⁵⁴Fe

Procedia PDF Downloads 82
1529 Food Irradiation in the Third Sector Development and Validation of Questionnaire to Standard Measuring Instrument for Evaluation of Acceptance and Sensory Analysis of Irradiated Foods

Authors: Juliana Sagretti, Susy Sabato

Abstract:

Despite the poverty in the world, a third of all food produced in the world is wasted. FAO, the United Nations Organization of Agriculture and Food, points out the need to combine actions and new technologies to combat hunger and waste in contrast to the high production of food in the world. The energy of ionizing radiation in food brought many positive results, such as increased validity and insect infestation control. The food banks are organizations that act at various points of food chain to collect and distribute food to the needy. So, the aim of this study was to initiate a partnership between irradiation and the food bank through the development of a questionnaire to evaluate and disseminate the knowledge and acceptance of individuals in the food bank in Brazil. In addition, this study aimed to standardize a basis questionnaire for future research assessment of irradiated foods. For the construction of the questionnaire as a measuring instrument, a comprehensive and rigorous literature review was made. Its covered qualitative research, questionnaires, sensory evaluation and food irradiated. Three stages of pre - tests were necessary and related fields of experts were consulted. As a result, the questionnaire has three parts, personal issues, assertive issues and questions of multiple choices and finally an informative question. The questionnaire was applied in Ceagesp food bank in the biggest center of food in Brazil (data not shown).

Keywords: food bank, food irradiation, food waste, sustainability

Procedia PDF Downloads 291
1528 Astronmical Panels of Measuring and Dividing Time in Ancient Egypt

Authors: Laila Mahrous Moursy Moawad El-Habiby

Abstract:

The ancient Egyptian used the stars to measure time or in a more precise sense as one of the astronomical means of measuring time. These methods differed throughout the historical ages. They began with simple observations of observing astronomical phenomena and watching them, such as observing the movements of the stars in the sky. The year, to know the days, nights, and other means used to help set the time when the sky overcast, and so the researcher tries through archaeological evidence to demonstrate the knowledge of the ancient Egyptian stars of heaven, and movements through the first pre-history. It is not believed that the astronomical information possessed by the Egyptian was limited, and simple, it was reaching a level of almost optimal in terms of importance, and the goal he wanted to reach the ancient Egyptian, and also help him to know the time, and the passage of time; which ended in finally trying to find a system of timing and calculation of time. It was noted that there were signs that the stellar creed was known, and prosperous, especially since the pre-family ages, and this is evident on the inscriptions that come back to that period. The Egyptian realized that some of the stars remain visible at night, The ancient Egyptian was familiar with the daily journey of the stars. This is what was adopted in many paragraphs of the texts of the pyramids, and its references to the rise of the deceased king of the heavenly world between the stars of the eternal sky. It was noted that the ancient Egyptian link between the doctrine of the star, we find that the public The lunar was known to the ancient Egyptian, and sang it for two years: and the stellar solar; but it was based on the appearance of the star Sirius, and this is the first means used to measure time, and know the calendar stars.

Keywords: archaeology, ancient Egypt, ancient Egyptian, astronomical panels

Procedia PDF Downloads 54
1527 Astronmical Panels of Measuring and Dividing Time in Ancient Egypt

Authors: Haitham Nabil Zaghlol Hasan

Abstract:

The ancient Egyptian used the stars to measure time or, in a more precise sense, as one of the astronomical means of measuring time. These methods differed throughout the historical ages. They began with simple observations of observing astronomical phenomena and watching them, such as observing the movements of the stars in the sky. The year, to know the days, nights, and other means used to help set the time when the sky overcast, and so the researcher tries through archaeological evidence to demonstrate the knowledge of the ancient Egyptian stars of heaven and movements through the first pre-history. It is not believed that the astronomical information possessed by the Egyptian was limited and simple, it was reaching a level of almost optimal in terms of importance, and the goal he wanted to reach the ancient Egyptian and also help him to know the time, and the passage of time; which ended in finally trying to find a system of timing and calculation of time. It was noted that there were signs that the stellar creed was known and prosperous, especially since the pre-family ages, and this is evident on the inscriptions that come back to that period. The Egyptian realized that some of the stars remain visible at night, The ancient Egyptian was familiar with the daily journey of the stars. This is what was adopted in many paragraphs of the texts of the pyramids and its references to the rise of the deceased king of the heavenly world between the stars of the eternal sky. It was noted that the ancient Egyptian link between the doctrine of the star, we find that the public The lunar was known to the ancient Egyptian, and sang it for two years: and the stellar solar; but it was based on the appearance of the star Sirius, and this is the first means used to measure time and know the calendar stars.

Keywords: ancient Egypt, astronmical panels, archaeology, civilization

Procedia PDF Downloads 48