Search results for: bypass diode
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 294

Search results for: bypass diode

264 Heat Exchanger Optimization of a Domestic Refrigerator with Separate Cooling Circuits

Authors: Tugba Tosun, Mert Tosun

Abstract:

Cooling system performance and energy consumption in the bypass two-circuit cycle have been studied experimentally to find optimum evaporator type and geometry, capillary tube diameter and capillary length. Two types of evaporators, such as wire on the tube and finned tube evaporators were used for the experiments in the fresh food compartment. As capillary tube inner diameter and total length; 0.66 mm and 0.8mm, and 3000 mm and 3500 mm were selected as parameters, respectively. Experiments were performed at the 25⁰C ambient temperature while the average temperature of the fresh food compartment is kept at 5⁰C and the highest package temperature of the freezer compartment is kept at -18⁰C, which are defined in IEC 62552 European standard. The Design of Experiments (DOE) technique which is six sigma method has been used to indicate of effective parameters in the bypass two-circuit cycle. The experimental results revealed that the most effective parameter of the system is the evaporator type. Finned tube evaporator with 12 tube passes was found as the best option for the bypass two-circuit refrigeration cycle among the 8 different opportunities. The optimum cooling performance and the lowest energy consumption were provided with 0.66 mm capillary tube inner diameter and 3500 mm capillary tube length.

Keywords: capillary tube, energy consumption, heat exchanger, refrigerator, separate cooling circuits

Procedia PDF Downloads 133
263 SiC Merged PiN and Schottky (MPS) Power Diodes Electrothermal Modeling in SPICE

Authors: A. Lakrim, D. Tahri

Abstract:

This paper sets out a behavioral macro-model of a Merged PiN and Schottky (MPS) diode based on silicon carbide (SiC). This model holds good for both static and dynamic electrothermal simulations for industrial applications. Its parameters have been worked out from datasheets curves by drawing on the optimization method: Simulated Annealing (SA) for the SiC MPS diodes made available in the industry. The model also adopts the Analog Behavioral Model (ABM) of PSPICE in which it has been implemented. The thermal behavior of the devices was also taken into consideration by making use of Foster’ canonical network as figured out from electro-thermal measurement provided by the manufacturer of the device.

Keywords: SiC MPS diode, electro-thermal, SPICE model, behavioral macro-model

Procedia PDF Downloads 380
262 Pressure Surge Analysis for Al Gardabiya Pump Station Phase III of the Man-Made River Project

Authors: Ahmed Bensreti, Mohamed Gouarsha

Abstract:

This paper presents a review of the pressure surge simulations carried out for Phase III of the Man Made River project in Libya with particular emphasis on the transient generated by simultaneous pump trips at Al Gardabiya Pump Station. The omission of the surge vessel check valve and bypass system on the grounds of cost, ease of design, and construction will result in, as expected, increased surge fluctuations as the damping effect in the form was removed. From the hydraulic and control requirements, it is recommended for Al Gardabiya Pump station that the check valve and check valve bypass be included in the final surge vessel design.

Keywords: computational fluid dynamics, surge vessel design, transient surge analysis, water pipe hydraulics

Procedia PDF Downloads 37
261 Arginase Activity and Nitric Oxide Levels in Patients Undergoing Open Heart Surgery with Cardiopulmonary Bypass

Authors: Mehmet Ali Kisaçam, P. Sema Temizer Ozan, Ayşe Doğan, Gonca Ozan, F. Sarper Türker

Abstract:

Cardiovascular disease which is one of the most common health problems worldwide has crucial importance because of its’ morbidity and mortality rates. Nitric oxide synthase and arginase use L-arginine as a substrate and produce nitric oxide (NO), citrulline and urea, ornithine respectively. Endothelial dysfunction is characterized by reduced bioavailability of vasodilator and anti-inflammatory molecule NO. The purpose of the study to assess endothelial function via arginase activity and NO levels in patients undergoing coronary artery bypass grafting (CABG) surgery. The study was conducted on 26 patients (14 male, 12 female) undergoing CABG surgery. Blood samples were collected from the subjects before surgery, after the termination and after 24 hours of the surgery. Arginase activity and NO levels measured in collected samples spectrophotometrically. Arginase activity decreased significantly in subjects after the termination of the surgery compared to before surgery data. 24 hours after the surgery there wasn’t any significance in arginase activity as it compared to before surgery and after the termination of the surgery. On the other hand, NO levels increased significantly in the subject after the termination of the surgery. However there was no significant increase in NO levels after 24 hours of the surgery, but there was an insignificant increase compared to before surgery data. The results indicate that after the termination of the surgery vascular and endothelial function improved and after 24 hours of the surgery arginase activity and NO levels returned to normal.

Keywords: arginase, bypass, cordiopulmonary, nitric oxide

Procedia PDF Downloads 183
260 Chaotic Electronic System with Lambda Diode

Authors: George Mahalu

Abstract:

The Chua diode has been configured over time in various ways, using electronic structures like operational amplifiers (AOs) or devices with gas or semiconductors. When discussing the use of semiconductor devices, tunnel diodes (Esaki diodes) are most often considered, and more recently, transistorized configurations such as lambda diodes. The paperwork proposed here uses in the modeling a lambda diode type configuration consisting of two junction field effect transistors (JFET). The original scheme is created in the MULTISIM electronic simulation environment and is analyzed in order to identify the conditions for the appearance of evolutionary unpredictability specific to nonlinear dynamic systems with chaos-induced behavior. The chaotic deterministic oscillator is one autonomous type, a fact that places it in the class of Chua’s type oscillators, the only significant and most important difference being the presence of a nonlinear device like the one mentioned structure above. The chaotic behavior is identified both by means of strange attractor-type trajectories and visible during the simulation and by highlighting the hypersensitivity of the system to small variations of one of the input parameters. The results obtained through simulation and the conclusions drawn are useful in the further research of ways to implement such constructive electronic solutions in theoretical and practical applications related to modern small signal amplification structures, to systems for encoding and decoding messages through various modern ways of communication, as well as new structures that can be imagined both in modern neural networks and in those for the physical implementation of some requirements imposed by current research with the aim of obtaining practically usable solutions in quantum computing and quantum computers.

Keywords: chua, diode, memristor, chaos

Procedia PDF Downloads 57
259 Mild Hypothermia Versus Normothermia in Patients Undergoing Cardiac Surgery: A Propensity Matched Analysis

Authors: Ramanish Ravishankar, Azar Hussain, Mahmoud Loubani, Mubarak Chaudhry

Abstract:

Background and Aims: Currently, there are no strict guidelines in cardiopulmonary bypass temperature management in cardiac surgery not involving the aortic arch. This study aims to compare patient outcomes undergoing mild hypothermia and normothermia. The aim of this study was to compare patient outcomes between mild hypothermia and normothermia undergoing on-pump cardiac surgery not involving the aortic arch. Methods: This was a retrospective cohort study from January 2015 until May 2023. Patients who underwent cardiac surgery with cardiopulmonary bypass temperatures ≥32oC were included and stratified into mild hypothermia (32oC – 35oC) and normothermia (>35oC) cohorts. Propensity matching was applied through the nearest neighbour method (1:1) using the risk factors detailed in the EuroScore using RStudio. The primary outcome was mortality. Secondary outcomes included post-op stay, intensive care unit readmission, re-admission, stroke, and renal complications. Patients who had major aortic surgery and off-pump operations were excluded. Results: Each cohort had 1675 patients. There was a significant increase in overall mortality with the mild hypothermia cohort (3.59% vs. 2.32%; p=0.04912). There was also a greater stroke incidence (2.09% vs. 1.13%; p=0.0396) and transient ischaemic attack (TIA) risk (3.1% vs. 1.49%; p=0.0027). There was no significant difference in renal complications (9.13% vs. 7.88%; p=0.2155). Conclusions: Patient’s who underwent mild hypothermia during cardiopulmonary bypass have a significantly greater mortality, stroke, and transient ischaemic attack incidence. Mild hypothermia does not appear to provide any benefit over normothermia and does not appear to provide any neuroprotective benefits. This shows different results to that of other major studies; further trials and studies need to be conducted to reach a consensus.

Keywords: cardiac surgery, therapeutic hypothermia, neuroprotection, cardiopulmonary bypass

Procedia PDF Downloads 43
258 An Improved Visible Range Absorption Spectroscopy on Soil Macronutrient

Authors: Suhaila Isaak, Yusmeeraz Yusof, Khairunnisa Mohd Yusof, Ahmad Safuan Abdul Rashid

Abstract:

Soil fertility is commonly evaluated by soil macronutrients such as nitrate, potassium, and phosphorus contents. Optical spectroscopy is an emerging technology which is rapid and simple has been widely used in agriculture to measure soil fertility. For visible and near infrared absorption spectroscopy, the absorbed light level in is useful for soil macro-nutrient measurement. This is because the absorption of light in a soil sample influences sensitivity of the measurement. This paper reports the performance of visible and near infrared absorption spectroscopy in the 400–1400 nm wavelength range using light-emitting diode as the excitation light source to predict the soil macronutrient content of nitrate, potassium, and phosphorus. The experimental results show an improved linear regression analysis of various soil specimens based on the Beer–Lambert law to determine sensitivity of soil spectroscopy by evaluating the absorption of characteristic peaks emitted from a light-emitting diode and detected by high sensitivity optical spectrometer. This would denote in developing a simple and low-cost soil spectroscopy with light-emitting diode for future implementation.

Keywords: macronutrients absorption, optical spectroscopy, soil, absorption

Procedia PDF Downloads 255
257 Chaotic Electronic System with Lambda Diode

Authors: George Mahalu

Abstract:

The Chua diode has been configured over time in various ways, using electronic structures like as operational amplifiers (OAs) or devices with gas or semiconductors. When discussing the use of semiconductor devices, tunnel diodes (Esaki diodes) are most often considered, and more recently, transistorized configurations such as lambda diodes. The paper-work proposed here uses in the modeling a lambda diode type configuration consisting of two Junction Field Effect Transistors (JFET). The original scheme is created in the MULTISIM electronic simulation environment and is analyzed in order to identify the conditions for the appearance of evolutionary unpredictability specific to nonlinear dynamic systems with chaos-induced behavior. The chaotic deterministic oscillator is one autonomous type, a fact that places it in the class of Chua’s type oscillators, the only significant and most important difference being the presence of a nonlinear device like the one mentioned structure above. The chaotic behavior is identified both by means of strange attractor-type trajectories and visible during the simulation and by highlighting the hypersensitivity of the system to small variations of one of the input parameters. The results obtained through simulation and the conclusions drawn are useful in the further research of ways to implement such constructive electronic solutions in theoretical and practical applications related to modern small signal amplification structures, to systems for encoding and decoding messages through various modern ways of communication, as well as new structures that can be imagined both in modern neural networks and in those for the physical implementation of some requirements imposed by current research with the aim of obtaining practically usable solutions in quantum computing and quantum computers.

Keywords: chaos, lambda diode, strange attractor, nonlinear system

Procedia PDF Downloads 50
256 Beating Heart Coronary Artery Bypass Grafting on Intermittent Pump Support

Authors: Sushil Kumar Singh, Vivek Tewarson, Sarvesh Kumar, Shobhit Kumar

Abstract:

Objective: ‘Beating Heart coronary artery bypass grafting on Intermittent Pump Support’ is a more reliable method of coronary revascularization that takes advantage of off and on-pump CABG while eliminating the disadvantage of both techniques. Methods: From January 2015 to December 2021, a new technique, “Intermittent On pump beating heart CABG” using a suction stabilizer was used by putting aortic and venous cannulas electively in all the patients. Patients were supported by a pump intermittently, as and when required (Group 1, n=254). Retrospective data were collected from our record of the patients who underwent off-pump CABG electively by the same surgeon and team (Group 2, n=254). Results: Significant advantage was noted in Group 1 patients in terms of the number of grafts (3.31 ± 1.16 vs. 2.30 ±0.66), grafting of lateral vessels (316 vs.202), mean operating time (1.37 ± 0.23 hrs vs. 2.22 ± 0.45 hrs) and postoperative blood loss (406.30 ± 257.90 ml vs. 567.41 ± 265.20 ml).CPB support time was less than 15 minutes in the majority of patients (n=179, 70.37 %), with a mean of 16.81 minutes. It was required, particularly during the grafting of lateral vessels. A rise in enzymes level (CRP, CKMB, Trop I, and NTPro BNP) was noted in Group 1 patients. But, these did not affect the postoperative course in patients. There was no mortality in Group 1 patients, while four patients in Group 2 died. Coclusions: Intermittent on-pump CABG technique is a promising method of surgical revascularization for all patients requiring CABG. It has shown its superiority in terms of safety, the number of grafts, operating time, and better perioperative course.

Keywords: cardiopulmonary bypass, CABG, beating heart CABG, on-pump CABG

Procedia PDF Downloads 87
255 Simulation of I–V Characteristics of Lateral PIN Diode on Polysilicon Films

Authors: Abdelaziz Rabhi, Mohamed Amrani, Abderrazek Ziane, Nabil Belkadi, Abdelraouf Hocini

Abstract:

In this paper, a bedimensional simulation program of the electric characteristics of reverse biased lateral polysilicon PIN diode is presented. In this case we have numerically solved the system of partial differential equations formed by Poisson's equation and both continuity equations that take into account the effect of impact ionization. Therefore we will obtain the current-voltage characteristics (I-V) of the reverse-biased structure which may include the effect of breakdown.The geometrical model assumes that the polysilicon layer is composed by a succession of defined mean grain size crystallites, separated by lateral grain boundaries which are parallel to the metallurgic junction.

Keywords: breakdown, polycrystalline silicon, PIN, grain, impact ionization

Procedia PDF Downloads 340
254 A Rare Case of Acquired Benign Tracheoesophageal Fistula: Case Report and Literature Review

Authors: Sarah Bouayyad, Ajay Nigam, Meera Beena

Abstract:

Acquired benign tracheoesophageal fistula is a rare medical condition that usually results from trauma, foreign bodies, or granulomatous infections. This is an unusual presentation of a male patient with a history of laryngectomy who had had over a period of several years inappropriately and vigorously used valve cleaning brushes to clean tracheal secretions, which had led to the formation of a tracheoesophageal fistula. Due to the patient’s obsessive habit, we couldn’t manage him using conventional surgical methods. Instead, we opted for the placement of a salivary bypass tube, which yielded good results and recovery. To the best of our knowledge, no other case of similar etiology has been published. We would like to highlight the importance of appropriate patient selection and education prior to performing a tracheoesophageal puncture to avoid developing life-threatening complications as demonstrated in our case report.

Keywords: tracheoesophageal fistula, speech valve, endoscopic insertion of salivary bypass tube, head and neck malignancies

Procedia PDF Downloads 97
253 Flip-Chip Bonding for Monolithic of Matrix-Addressable GaN-Based Micro-Light-Emitting Diodes Array

Authors: Chien-Ju Chen, Chia-Jui Yu, Jyun-Hao Liao, Chia-Ching Wu, Meng-Chyi Wu

Abstract:

A 64 × 64 GaN-based micro-light-emitting diode array (μLEDA) with 20 μm in pixel size and 40 μm in pitch by flip-chip bonding (FCB) is demonstrated in this study. Besides, an underfilling (UF) technology is applied to the process for improving the uniformity of device. With those configurations, good characteristics are presented, operation voltage and series resistance of a pixel in the 450 nm flip chip μLEDA are 2.89 V and 1077Ω (4.3 mΩ-cm²) at 25 A/cm², respectively. The μLEDA can sustain higher current density compared to conventional LED, and the power of the device is 9.5 μW at 100 μA and 0.42 mW at 20 mA.

Keywords: GaN, micro-light-emitting diode array(μLEDA), flip-chip bonding, underfilling

Procedia PDF Downloads 391
252 An Adaptive Controller Method Based on Full-State Linear Model of Variable Cycle Engine

Authors: Jia Li, Huacong Li, Xiaobao Han

Abstract:

Due to the more variable geometry parameters of VCE (variable cycle aircraft engine), presents an adaptive controller method based on the full-state linear model of VCE and has simulated to solve the multivariate controller design problem of the whole flight envelops. First, analyzes the static and dynamic performances of bypass ratio and other state parameters caused by variable geometric components, and develops nonlinear component model of VCE. Then based on the component model, through small deviation linearization of main fuel (Wf), the area of tail nozzle throat (A8) and the angle of rear bypass ejector (A163), setting up multiple linear model which variable geometric parameters can be inputs. Second, designs the adaptive controllers for VCE linear models of different nominal points. Among them, considering of modeling uncertainties and external disturbances, derives the adaptive law by lyapunov function. The simulation results showed that, the adaptive controller method based on full-state linear model used the angle of rear bypass ejector as input and effectively solved the multivariate control problems of VCE. The performance of all nominal points could track the desired closed-loop reference instructions. The adjust time was less than 1.2s, and the system overshoot was less than 1%, at the same time, the errors of steady states were less than 0.5% and the dynamic tracking errors were less than 1%. In addition, the designed controller could effectively suppress interference and reached the desired commands with different external random noise signals.

Keywords: variable cycle engine (VCE), full-state linear model, adaptive control, by-pass ratio

Procedia PDF Downloads 291
251 High-Performance Liquid Chromatographic Method with Diode Array Detection (HPLC-DAD) Analysis of Naproxen and Omeprazole Active Isomers

Authors: Marwa Ragab, Eman El-Kimary

Abstract:

Chiral separation and analysis of omeprazole and naproxen enantiomers in tablets were achieved using high-performance liquid chromatographic method with diode array detection (HPLC-DAD). Kromasil Cellucoat chiral column was used as a stationary phase for separation and the eluting solvent consisted of hexane, isopropanol and trifluoroacetic acid in a ratio of: 90, 9.9 and 0.1, respectively. The chromatographic system was suitable for the enantiomeric separation and analysis of active isomers of the drugs. Resolution values of 2.17 and 3.84 were obtained after optimization of the chromatographic conditions for omeprazole and naproxen isomers, respectively. The determination of S-isomers of each drug in their dosage form was fully validated.

Keywords: chiral analysis, esomeprazole, S-Naproxen, HPLC-DAD

Procedia PDF Downloads 281
250 A Study on Evaluation for Performance Verification of Ni-63 Radioisotope Betavoltaic Battery

Authors: Youngmok Yun, Bosung Kim, Sungho Lee, Kyeongsu Jeon, Hyunwook Hwangbo, Byounggun Choi

Abstract:

A betavoltaic battery converts nuclear energy released as beta particles (β-) directly into electrical energy. Betavoltaic cells are analogous to photovoltaic cells. The beta particle’s kinetic energy enters a p-n junction and creates electron-hole pairs. Subsequently, the built-in potential of the p-n junction accelerates the electrons and ions to their respective collectors. The major challenges are electrical conversion efficiencies and exact evaluation. In this study, the performance of betavoltaic battery was evaluated. The betavoltaic cell was evaluated in the same condition as radiation from radioactive isotope using by FE-SEM(field emission scanning electron microscope). The average energy of the radiation emitted from the Ni-63 radioisotope is 17.42 keV. FE-SEM is capable of emitting an electron beam of 1-30keV. Therefore, it is possible to evaluate betavoltaic cell without radioactive isotopes. The betavoltaic battery consists of radioisotope that is physically connected on the surface of Si-based PN diode. The performance of betavoltaic battery can be estimated by the efficiency of PN diode unit cell. The current generated by scanning electron microscope with fixed accelerating voltage (17keV) was measured by using faraday cup. Electrical characterization of the p-n junction diode was performed by using Nano Probe Work Station and I-V measurement system. The output value of the betavoltaic cells developed by this research team was 0.162 μw/cm2 and the efficiency was 1.14%.

Keywords: betavoltaic, nuclear, battery, Ni-63, radio-isotope

Procedia PDF Downloads 233
249 The Incidence of Postoperative Atrial Fibrillation after Coronary Artery Bypass Grafting in Patients with Local and Diffuse Coronary Artery Disease

Authors: Kamil Ganaev, Elina Vlasova, Andrei Shiryaev, Renat Akchurin

Abstract:

De novo atrial fibrillation (AF) after coronary artery bypass grafting (CABG) is a common complication. To date, there are no data on the possible effect of diffuse lesions of coronary arteries on the incidence of postoperative AF complications. Methods. Patients operated on-pump under hypothermic conditions during the calendar year (2020) were studied. Inclusion criteria - isolated CABG and achievement of complete myocardial revascularization. Patients with a history of AF moderate and severe valve dysfunction, hormonal thyroid pathology, initial CHF(Congestive heart failure), as well as patients with developed perioperative complications (IM, acute heart failure, massive blood loss) and deceased were excluded. Thus 227 patients were included; mean age 65±9 years; 69% were men. 89% of patients had a 3-vessel lesion of the coronary artery; the remainder had a 2-vessel lesion. Mean LV size: 3.9±0.3 cm, indexed LV volume: 29.4±5.3 mL/m2. Two groups were considered: D (n=98), patients with diffuse coronary heart disease, and L (n=129), patients with local coronary heart disease. Clinical and demographic characteristics in the groups were comparable. Rhythm assessment: continuous bedside ECG monitoring up to 5 days; ECG CT at 5-7 days after CABG; daily routine ECG registration. Follow-up period - postoperative hospital period. Results. The Median follow-up period was 9 (7;11) days. POFP (Postoperative atrial fibrillation) was detected in 61/227 (27%) patients: 34/98 (35%) in group D versus 27/129 (21%) in group L; p<0.05. Moreover, the values of revascularization index in groups D and L (3.9±0.7 and 3.8±0.5, respectively) were equal, and the mean time Cardiopulmonary bypass (CPB) (107±27 and 80±13min), as well as the mean ischemic time (67±17 and 55±11min) were significantly longer in group D (p<0.05). However, a separate analysis of these parameters in patients with and without developed AF did not reveal any significant differences in group D (CPB time 99±21.2 min, ischemic time 63±12.2 min), or in group L (CPB time 88±13.1 min, ischemic time 58.7±13.2 min). Conclusion. With the diffuse nature of coronary lesions, the incidence of AF in the hospital period after isolated CABG definitely increases. To better understand the role of severe coronary atherosclerosis in the development of POAF, it is necessary to distinguish the influence of organic features of atrial and ventricular myocardium (as a consequence of chronic coronary disease) from the features of surgical correction in diffuse coronary lesions.

Keywords: atrial fibrillation, diffuse coronary artery disease, coronary artery bypass grafting, local coronary artery disease

Procedia PDF Downloads 183
248 Characterization of current–voltage (I–V) and capacitance–voltage–frequency (C–V–f) features of Au/GaN Schottky diodes

Authors: Abdelaziz Rabehi

Abstract:

The current–voltage (I–V) characteristics of Au/GaN Schottky diodes were measured at room temperature. In addition, capacitance–voltage–frequency (C–V–f) characteristics are investigated by considering the interface states (Nss) at frequency range 100 kHz to 1 MHz. From the I–V characteristics of the Schottky diode, ideality factor (n) and barrier height (Φb) values of 1.22 and 0.56 eV, respectively, were obtained from a forward bias I–V plot. In addition, the interface states distribution profile as a function of (Ess − Ev) was extracted from the forward bias I–V measurements by taking into account the bias dependence of the effective barrier height (Φe) for the Schottky diode. The C–V curves gave a barrier height value higher than those obtained from I–V measurements. This discrepancy is due to the different nature of the I–V and C–V measurement techniques.

Keywords: Schottky diodes, frequency dependence, barrier height, interface states

Procedia PDF Downloads 279
247 AI-Driven Strategies for Sustainable Electronics Repair: A Case Study in Energy Efficiency

Authors: Badiy Elmabrouk, Abdelhamid Boujarif, Zhiguo Zeng, Stephane Borrel, Robert Heidsieck

Abstract:

In an era where sustainability is paramount, this paper introduces a machine learning-driven testing protocol to accurately predict diode failures, merging reliability engineering with failure physics to enhance repair operations efficiency. Our approach refines the burn-in process, significantly curtailing its duration, which not only conserves energy but also elevates productivity and mitigates component wear. A case study from GE HealthCare’s repair center vividly demonstrates the method’s effectiveness, recording a high prediction of diode failures and a substantial decrease in energy consumption that translates to an annual reduction of 6.5 Tons of CO2 emissions. This advancement sets a benchmark for environmentally conscious practices in the electronics repair sector.

Keywords: maintenance, burn-in, failure physics, reliability testing

Procedia PDF Downloads 25
246 Investigating the Energy Gap and Wavelength of (AlₓGa₁₋ₓAs)ₘ/(GaAs)ₙ Superlattices in Terms of Material Thickness and Al Mole Fraction Using Empirical Tight-Binding Method

Authors: Matineh Sadat Hosseini Gheidari, Vahid Reza Yazdanpanah

Abstract:

In this paper, we used the empirical tight-binding method (ETBM) with sp3s* approximation and considering the first nearest neighbor with spin-orbit interactions in order to model superlattice structure (SLS) of (AlₓGa₁₋ₓAs)ₘ/(GaAs)ₙ grown on GaAs (100) substrate at 300K. In the next step, we investigated the behavior of the energy gap and wavelength of this superlattice in terms of different thicknesses of core materials and Al mole fractions. As a result of this survey, we found out that as the Al composition increases, the energy gap of this superlattice has an upward trend and ranges from 1.42-1.63 eV. Also, according to the wavelength range that we gained from this superlattice in different Al mole fractions and various thicknesses, we can find a suitable semiconductor for a special light-emitting diode (LED) application.

Keywords: energy gap, empirical tight-binding method, light-emitting diode, superlattice, wavelength

Procedia PDF Downloads 159
245 Direct Power Control Applied on 5-Level Diode Clamped Inverter Powered by a Renewable Energy Source

Authors: A. Elnady

Abstract:

This paper presents an improved Direct Power Control (DPC) scheme applied to the multilevel inverter that forms a Distributed Generation Unit (DGU). This paper demonstrates the performance of active and reactive power injected by the DGU to the smart grid. The DPC is traditionally operated by the hysteresis controller with the Space Vector Modulation (SVM) which is applied on the 2-level inverters or 3-level inverters. In this paper, the DPC is operated by the PI controller with the Phase-Disposition Pulse Width Modulation (PD-PWM) applied to the 5-level diode clamped inverter. The new combination of the DPC, PI controller, PD-PWM and multilevel inverter proves that its performance is much better than the conventional hysteresis-SVM based DPC. Simulations results have been presented to validate the performance of the suggested control scheme in the grid-connected mode.

Keywords: direct power control, PI controller, PD-PWM, and power control

Procedia PDF Downloads 219
244 Comparative Analysis of SVPWM and the Standard PWM Technique for Three Level Diode Clamped Inverter fed Induction Motor

Authors: L. Lakhdari, B. Bouchiba, M. Bechar

Abstract:

The multi-level inverters present an important novelty in the field of energy control with high voltage and power. The major advantage of all multi-level inverters is the improvement and spectral quality of its generated output signals. In recent years, various pulse width modulation techniques have been developed. From these technics we have: Sinusoidal Pulse Width Modulation (SPWM) and Space Vector Pulse Width Modulation (SVPWM). This work presents a detailed analysis of the comparative advantage of space vector pulse width modulation (SVPWM) and the standard SPWM technique for Three Level Diode Clamped Inverter fed Induction Motor. The comparison is based on the evaluation of harmonic distortion THD.

Keywords: induction motor, multilevel inverters, SVPWM, SPWM, THD

Procedia PDF Downloads 309
243 2106 kA/cm² Peak Tunneling Current Density in GaN-Based Resonant Tunneling Diode with an Intrinsic Oscillation Frequency of ~260GHz at Room Temperature

Authors: Fang Liu, JunShuai Xue, JiaJia Yao, GuanLin Wu, ZuMaoLi, XueYan Yang, HePeng Zhang, ZhiPeng Sun

Abstract:

Terahertz spectra is in great demand since last two decades for many photonic and electronic applications. III-Nitride resonant tunneling diode is one of the promising candidates for portable and compact THz sources. Room temperature microwave oscillator based on GaN/AlN resonant tunneling diode was reported in this work. The devices, grown by plasma-assisted molecular-beam epitaxy on free-standing c-plane GaN substrates, exhibit highly repeatable and robust negative differential resistance (NDR) characteristics at room temperature. To improve the interface quality at the active region in RTD, indium surfactant assisted growth is adopted to enhance the surface mobility of metal atoms on growing film front. Thanks to the lowered valley current associated with the suppression of threading dislocation scattering on low dislocation GaN substrate, a positive peak current density of record-high 2.1 MA/cm2 in conjunction with a peak-to-valley current ratio (PVCR) of 1.2 are obtained, which is the best results reported in nitride-based RTDs up to now considering the peak current density and PVCR values simultaneously. When biased within the NDR region, microwave oscillations are measured with a fundamental frequency of 0.31 GHz, yielding an output power of 5.37 µW. Impedance mismatch results in the limited output power and oscillation frequency described above. The actual measured intrinsic capacitance is only 30fF. Using a small-signal equivalent circuit model, the maximum intrinsic frequency of oscillation for these diodes is estimated to be ~260GHz. This work demonstrates a microwave oscillator based on resonant tunneling effect, which can meet the demands of terahertz spectral devices, more importantly providing guidance for the fabrication of the complex nitride terahertz and quantum effect devices.

Keywords: GaN resonant tunneling diode, peak current density, microwave oscillation, intrinsic capacitance

Procedia PDF Downloads 104
242 The Effect of Health Promoting Programs on Patient's Life Style after Coronary Artery Bypass Graft–Hospitalized in Shiraz Hospitals

Authors: Azizollah Arbabisarjou, Leila Safabakhsh, Mozhgan Jahantigh, Mahshid Nazemzadeh, Shahindokht Navabi

Abstract:

Background: Health promotion is an essential strategy for reduction of health disparities. Health promotion includes all activities that encourage optimum physical, spiritual, and mental function. The aim of this study was to determine the impact of a Health Promotion Program (HPP) on behavior in terms of the dimensions of the Health Promoting Lifestyle Profile (HPLP) in patients after Coronary Artery Bypass Graft (CABG). Methods and Materials: In this clinical trial study, 80 patients who had undergone CABG surgery (2011-2012) were selected and randomly divided in two groups: Experimental and Control that investigated by (HPLP II). Then the experimental group was educated about diet, walking and stress management. The program process was followed up for 3months and after that all variables were investigated again. The overall score and the scores for the six dimensions of the HPLP (self-actualization, health responsibility, exercise, nutrition, interpersonal support and stress management) were measured in the pre- and post-test periods. Statistical analysis was performed using Student's t-test and paired t-test. Results: Results showed that Score of stress management (p=.036), diet (p=.002), Spiritual Growth (p=.001) and interrelationship (p=002) increase in experimental group after intervention .Average scores after 3 months in the control group had no significant changes; except responsibility for health (p < .05). Results of the study revealed that comparison the scores of the experimental group were significantly different from the control group in all lifestyle aspects except for spiritual growth. Conclusion: This study showed that Health promoting program on lifestyle and health promotion in patients who suffer from CAD could enhance patient's awareness of healthy behaviors and improves the quality of life.

Keywords: coronary artery bypass graft, health promotion, lifestyle, education

Procedia PDF Downloads 426
241 Performance of Armchair Graphene Nanoribbon Resonant Tunneling Diode under Uniaxial Strain

Authors: Milad Zoghi, M. Zahangir Kabir

Abstract:

Performance of armchair graphene nanoribbon (AGNR) resonant tunneling diodes (RTD) alter if they go under strain. This may happen due to either using stretchable substrates or real working conditions such as heat generation. Therefore, it is informative to understand how mechanical deformations such as uniaxial strain can impact the performance of AGNR RTDs. In this paper, two platforms of AGNR RTD consist of width-modified AGNR RTD and electric-field modified AGNR RTD are subjected to both compressive and tensile uniaxial strain ranging from -2% to +2%. It is found that characteristics of AGNR RTD markedly change under both compressive and tensile strain. In particular, peak to valley ratio (PVR) can be totally disappeared upon strong enough strain deformation. Numerical tight binding (TB) coupled with Non-Equilibrium Green's Function (NEGF) is derived for this study to calculate corresponding Hamiltonian matrices and transport properties.

Keywords: armchair graphene nanoribbon, resonant tunneling diode, uniaxial strain, peak to valley ratio

Procedia PDF Downloads 146
240 Comprehensive Validation of High-Performance Liquid Chromatography-Diode Array Detection (HPLC-DAD) for Quantitative Assessment of Caffeic Acid in Phenolic Extracts from Olive Mill Wastewater

Authors: Layla El Gaini, Majdouline Belaqziz, Meriem Outaki, Mariam Minhaj

Abstract:

In this study, it introduce and validate a high-performance liquid chromatography method with diode-array detection (HPLC-DAD) specifically designed for the accurate quantification of caffeic acid in phenolic extracts obtained from olive mill wastewater. The separation process of caffeic acid was effectively achieved through the use of an Acclaim Polar Advantage column (5µm, 250x4.6mm). A meticulous multi-step gradient mobile phase was employed, comprising water acidified with phosphoric acid (pH 2.3) and acetonitrile, to ensure optimal separation. The diode-array detection was adeptly conducted within the UV–VIS spectrum, spanning a range of 200–800 nm, which facilitated precise analytical results. The method underwent comprehensive validation, addressing several essential analytical parameters, including specificity, repeatability, linearity, as well as the limits of detection and quantification, alongside measurement uncertainty. The generated linear standard curves displayed high correlation coefficients, underscoring the method's efficacy and consistency. This validated approach is not only robust but also demonstrates exceptional reliability for the focused analysis of caffeic acid within the intricate matrices of wastewater, thus offering significant potential for applications in environmental and analytical chemistry.

Keywords: high-performance liquid chromatography (HPLC-DAD), caffeic acid analysis, olive mill wastewater phenolics, analytical method validation

Procedia PDF Downloads 30
239 LEDs Based Indoor Positioning by Distances Derivation from Lambertian Illumination Model

Authors: Yan-Ren Chen, Jenn-Kaie Lain

Abstract:

This paper proposes a novel indoor positioning algorithm based on visible light communications, implemented by light-emitting diode fixtures. In the proposed positioning algorithm, distances between light-emitting diode fixtures and mobile terminal are derived from the assumption of ideal Lambertian optic radiation model, and Trilateration positioning method is proceeded immediately to get the coordinates of mobile terminal. The proposed positioning algorithm directly obtains distance information from the optical signal modeling, and therefore, statistical distribution of received signal strength at different positions in interior space has no need to be pre-established. Numerically, simulation results have shown that the proposed indoor positioning algorithm can provide accurate location coordinates estimation.

Keywords: indoor positioning, received signal strength, trilateration, visible light communications

Procedia PDF Downloads 392
238 Predictors of Pericardial Effusion Requiring Drainage Following Coronary Artery Bypass Graft Surgery: A Retrospective Analysis

Authors: Nicholas McNamara, John Brookes, Michael Williams, Manish Mathew, Elizabeth Brookes, Tristan Yan, Paul Bannon

Abstract:

Objective: Pericardial effusions are an uncommon but potentially fatal complication after cardiac surgery. The goal of this study was to describe the incidence and risk factors associated with the development of pericardial effusion requiring drainage after coronary artery bypass graft surgery (CABG). Methods: A retrospective analysis was undertaken using prospectively collected data. All adult patients who underwent CABG at our institution between 1st January 2017 and 31st December 2018 were included. Pericardial effusion was diagnosed using transthoracic echocardiography (TTE) performed for clinical suspicion of pre-tamponade or tamponade. Drainage was undertaken if considered clinically necessary and performed via a sub-xiphoid incision, pericardiocentesis, or via re-sternotomy at the discretion of the treating surgeon. Patient demographics, operative characteristics, anticoagulant exposure, and postoperative outcomes were examined to identify those variables associated with the development of pericardial effusion requiring drainage. Tests of association were performed using the Fischer exact test for dichotomous variables and the Student t-test for continuous variables. Logistic regression models were used to determine univariate predictors of pericardial effusion requiring drainage. Results: Between January 1st, 2017, and December 31st, 2018, a total of 408 patients underwent CABG at our institution, and eight (1.9%) required drainage of pericardial effusion. There was no difference in age, gender, or the proportion of patients on preoperative therapeutic heparin between the study and control groups. Univariate analysis identified preoperative atrial arrhythmia (37.5% vs 8.8%, p = 0.03), reduced left ventricular ejection fraction (47% vs 56%, p = 0.04), longer cardiopulmonary bypass (130 vs 84 min, p < 0.01) and cross-clamp (107 vs 62 min, p < 0.01) times, higher drain output in the first four postoperative hours (420 vs 213 mL, p <0.01), postoperative atrial fibrillation (100% vs 32%, p < 0.01), and pleural effusion requiring drainage (87.5% vs 12.5%, p < 0.01) to be associated with development of pericardial effusion requiring drainage. Conclusion: In this study, the incidence of pericardial effusion requiring drainage was 1.9%. Several factors, mainly related to preoperative or postoperative arrhythmia, length of surgery, and pleural effusion requiring drainage, were identified to be associated with developing clinically significant pericardial effusions. High clinical suspicion and low threshold for transthoracic echo are pertinent to ensure this potentially lethal condition is not missed.

Keywords: coronary artery bypass, pericardial effusion, pericardiocentesis, tamponade, sub-xiphoid drainage

Procedia PDF Downloads 140
237 Electron Microscopical Analysis of Arterial Line Filters During Cardiopulmonary Bypass

Authors: Won-Gon Kim

Abstract:

Introduction: The clinical value of arterial line filters is still a controversial issue. Proponents of arterial line filtration argue that filters remove particulate matter and undissolved gas from circulation, while opponents argue the absence of conclusive clinical data. We conducted scanning electron microscope (SEM) studies of arterial line filters used clinically in the CPB circuits during adult cardiac surgery and analyzed the types and characteristics of materials entrapped in the arterial line filters. Material and Methods: Twelve arterial line filters were obtained during routine hypothermic cardiopulmonary bypass in 12 adult cardiac patients. The arterial line filter was a screen type with a pore size of 40 ㎛ (Baxter Health care corporation Bentley division, Irvine, CA, U.S.A.). After opening the housing, the woven polyester strands were examined with SEM. Results and Conclusion: All segments examined(120 segments, each 2.5 X 2.5 cm in size) contained no embolic particles larger in their cross-sectional area than the pore size of the filter(40 ㎛). The origins of embolic particulates were mostly from environmental foreign bodies. This may suggest a possible need for more aggressive filtration of smaller particulates than is generally carried out at the present time.

Keywords: arterial line filter, tubing wear, scanning electron microscopy, SEM

Procedia PDF Downloads 418
236 Developing and Evaluating Clinical Risk Prediction Models for Coronary Artery Bypass Graft Surgery

Authors: Mohammadreza Mohebbi, Masoumeh Sanagou

Abstract:

The ability to predict clinical outcomes is of great importance to physicians and clinicians. A number of different methods have been used in an effort to accurately predict these outcomes. These methods include the development of scoring systems based on multivariate statistical modelling, and models involving the use of classification and regression trees. The process usually consists of two consecutive phases, namely model development and external validation. The model development phase consists of building a multivariate model and evaluating its predictive performance by examining calibration and discrimination, and internal validation. External validation tests the predictive performance of a model by assessing its calibration and discrimination in different but plausibly related patients. A motivate example focuses on prediction modeling using a sample of patients undergone coronary artery bypass graft (CABG) has been used for illustrative purpose and a set of primary considerations for evaluating prediction model studies using specific quality indicators as criteria to help stakeholders evaluate the quality of a prediction model study has been proposed.

Keywords: clinical prediction models, clinical decision rule, prognosis, external validation, model calibration, biostatistics

Procedia PDF Downloads 267
235 Parametric Investigation of Aircraft Door’s Emergency Power Assist System (EPAS)

Authors: Marshal D. Kafle, Jun H. Kim, Hyun W. Been, Kyoung M. Min

Abstract:

Fluid viscous damping systems are well suited for many air vehicles subjected to shock and vibration. These damping system work with the principle of viscous fluid throttling through the orifice to create huge pressure difference between compression and rebound chamber and obtain the required damping force. One application of such systems is its use in aircraft door system to counteract the door’s velocity and safely stop it. In exigency situations like crash or emergency landing where the door doesn’t open easily, possibly due to unusually tilting of fuselage or some obstacles or intrusion of debris obstruction to move the parts of the door, such system can be combined with other systems to provide needed force to forcefully open the door and also securely stop it simultaneously within the required time i.e.less than 8seconds. In the present study, a hydraulic system called snubber along with other systems like actuator, gas bottle assembly which together known as emergency power assist system (EPAS) is designed, built and experimentally studied to check the magnitude of angular velocity, damping force and time required to effectively open the door. Whenever needed, the gas pressure from the bottle is released to actuate the actuator and at the same time pull the snubber’s piston to operate the emergency opening of the door. Such EPAS installed in the suspension arm of the aircraft door is studied explicitly changing parameters like orifice size, oil level, oil viscosity and bypass valve gap and its spring of the snubber at varying temperature to generate the optimum design case. Comparative analysis of the EPAS at several cases is done and conclusions are made. It is found that during emergency condition, the systemopening time and angular velocity, when snubber with 0.3mm piston and shaft orifice and bypass valve gap of 0.5 mm with its original spring is used,shows significant improvement over the old ones.

Keywords: aircraft door damper, bypass valve, emergency power assist system, hydraulic damper, oil viscosity

Procedia PDF Downloads 398