Search results for: total hip arthroplasty biomechanics
8923 Multiscale Model of Blast Explosion Human Injury Biomechanics
Authors: Raj K. Gupta, X. Gary Tan, Andrzej Przekwas
Abstract:
Bomb blasts from Improvised Explosive Devices (IEDs) account for vast majority of terrorist attacks worldwide. Injuries caused by IEDs result from a combination of the primary blast wave, penetrating fragments, and human body accelerations and impacts. This paper presents a multiscale computational model of coupled blast physics, whole human body biodynamics and injury biomechanics of sensitive organs. The disparity of the involved space- and time-scales is used to conduct sequential modeling of an IED explosion event, CFD simulation of blast loads on the human body and FEM modeling of body biodynamics and injury biomechanics. The paper presents simulation results for blast-induced brain injury coupling macro-scale brain biomechanics and micro-scale response of sensitive neuro-axonal structures. Validation results on animal models and physical surrogates are discussed. Results of our model can be used to 'replicate' filed blast loadings in laboratory controlled experiments using animal models and in vitro neuro-cultures.Keywords: blast waves, improvised explosive devices, injury biomechanics, mathematical models, traumatic brain injury
Procedia PDF Downloads 2498922 A Comparison and Discussion of Modern Anaesthetic Techniques in Elective Lower Limb Arthroplasties
Authors: P. T. Collett, M. Kershaw
Abstract:
Introduction: The discussion regarding which method of anesthesia provides better results for lower limb arthroplasty is a continuing debate. Multiple meta-analysis has been performed with no clear consensus. The current recommendation is to use neuraxial anesthesia for lower limb arthroplasty; however, the evidence to support this decision is weak. The Enhanced Recovery After Surgery (ERAS) society has recommended, either technique can be used as part of a multimodal anesthetic regimen. A local study was performed to see if the current anesthetic practice correlates with the current recommendations and to evaluate the efficacy of the different techniques utilized. Method: 90 patients who underwent total hip or total knee replacements at Nevill Hall Hospital between February 2019 to July 2019 were reviewed. Data collected included the anesthetic technique, day one opiate use, pain score, and length of stay. The data was collected from anesthetic charts, and the pain team follows up forms. Analysis: The average of patients undergoing lower limb arthroplasty was 70. Of those 83% (n=75) received a spinal anaesthetic and 17% (n=15) received a general anaesthetic. For patients undergoing knee replacement under general anesthetic the average day, one pain score was 2.29 and 1.94 if a spinal anesthetic was performed. For hip replacements, the scores were 1.87 and 1.8, respectively. There was no statistical significance between these scores. Day 1 opiate usage was significantly higher in knee replacement patients who were given a general anesthetic (45.7mg IV morphine equivalent) vs. those who were operated on under spinal anesthetic (19.7mg). This difference was not noticeable in hip replacement patients. There was no significant difference in length of stay between the two anesthetic techniques. Discussion: There was no significant difference in the day one pain score between the patients who received a general or spinal anesthetic for either knee or hip replacements. The higher pain scores in the knee replacement group overall are consistent with this being a more painful procedure. This is a small patient population, which means any difference between the two groups is unlikely to be representative of a larger population. The pain scale has 4 points, which means it is difficult to identify a significant difference between pain scores. Conclusion: There is currently little standardization between the different anesthetic approaches utilized in Nevill Hall Hospital. This is likely due to the lack of adherence to a standardized anesthetic regimen. In accordance with ERAS recommends a standard anesthetic protocol is a core component. The results of this study and the guidance from the ERAS society will support the implementation of a new health board wide ERAS protocol.Keywords: anaesthesia, orthopaedics, intensive care, patient centered decision making, treatment escalation
Procedia PDF Downloads 1278921 An Intelligent Steerable Drill System for Orthopedic Surgery
Authors: Wei Yao
Abstract:
A steerable and flexible drill is needed in orthopaedic surgery. For example, osteoarthritis is a common condition affecting millions of people for which joint replacement is an effective treatment which improves the quality and duration of life in elderly sufferers. Conventional surgery is not very accurate. Computer navigation and robotics can help increase the accuracy. For example, In Total Hip Arthroplasty (THA), robotic surgery is currently practiced mainly on acetabular side helping cup positioning and orientation. However, femoral stem positioning mostly uses hand-rasping method rather than robots for accurate positioning. The other case for using a flexible drill in surgery is Anterior Cruciate Ligament (ACL) Reconstruction. The majority of ACL Reconstruction failures are primarily caused by technical mistakes and surgical errors resulting from drilling the anatomical bone tunnels required to accommodate the ligament graft. The proposed new steerable drill system will perform orthopedic surgery through curved tunneling leading to better accuracy and patient outcomes. It may reduce intra-operative fractures, dislocations, early failure and leg length discrepancy by making possible a new level of precision. This technology is based on a robotically assisted, steerable, hand-held flexible drill, with a drill-tip tracking device and a multi-modality navigation system. The critical differentiator is that this robotically assisted surgical technology now allows the surgeon to prepare 'patient specific' and more anatomically correct 'curved' bone tunnels during orthopedic surgery rather than drilling straight holes as occurs currently with existing surgical tools. The flexible and steerable drill and its navigation system for femoral milling in total hip arthroplasty had been tested on sawbones to evaluate the accuracy of the positioning and orientation of femoral stem relative to the pre-operative plan. The data show the accuracy of the navigation system is better than traditional hand-rasping method.Keywords: navigation, robotic orthopedic surgery, steerable drill, tracking
Procedia PDF Downloads 1668920 Surgical Prep-Related Burns in Laterally Positioned Hip Procedures
Authors: B. Kenny, M. Dixon, A. Boshell
Abstract:
The use of alcoholic surgical prep was recently introduced into the Royal Newcastle Center for elective procedures. In the past 3 months there have been a significant number of burns believed to be related to ‘pooling’ of this surgical prep in patients undergoing procedures where they are placed in the lateral position with hip bolsters. The aim of the audit was to determine the reason for the burns, analyze what pre-existing factors may contribute to the development of the burns and what can be changed to prevent further burns occurring. All patients undergoing a procedure performed on the hip who were placed in the lateral position with sacral and anterior, superior iliac spine (ASIS) support with ‘bolsters’ were included in the audit. Patients who developed a ‘burn’ were recorded, details of the surgery, demographics, surgical prep used and length of surgery were obtained as well as photographs taken to document the burn. Measures were then taken to prevent further burns and the efficacy was documented. Overall 14 patients developed burns over the ipsilateral ASIS. Of these, 13 were Total Hip Arthroplasty (THA) and 1 was a removal of femoral nail. All patients had Chlorhexidine 0.5% in Alcohol 70% Tinted Red surgical preparation or Betadine Alcoholic Skin Prep (70% etoh). Patients were set up in the standard lateral decubitus position with sacral and bilateral ASIS bolsters with a valband covering. 86% of patients were found to have pre-existing hypersensitivities to various substances. There is very little literature besides a few case reports on surgical prep-related burns. The case reports that do exist are related to the use of tourniquet-related burns and there is no mention in the literature examining ‘bolster’ related burns. The burns are hypothesized to be caused by pooling of the alcoholic solution which is amplified by the use of Valband.Keywords: arthroplasty, chemical burns, wounds, rehabilitation
Procedia PDF Downloads 3008919 Surgical Hip Dislocation of Femoroacetabular Impingement: Survivorship and Functional Outcomes at 10 Years
Authors: L. Hoade, O. O. Onafowokan, K. Anderson, G. E. Bartlett, E. D. Fern, M. R. Norton, R. G. Middleton
Abstract:
Aims: Femoroacetabular impingement (FAI) was first recognised as a potential driver for hip pain at the turn of the last millennium. While there is an increasing trend towards surgical management of FAI by arthroscopic means, open surgical hip dislocation and debridement (SHD) remains the Gold Standard of care in terms of reported outcome measures. (1) Long-term functional and survivorship outcomes of SHD as a treatment for FAI are yet to be sufficiently reported in the literature. This study sets out to help address this imbalance. Methods: We undertook a retrospective review of our institutional database for all patients who underwent SHD for FAI between January 2003 and December 2008. A total of 223 patients (241 hips) were identified and underwent a ten year review with a standardised radiograph and patient-reported outcome measures questionnaire. The primary outcome measure of interest was survivorship, defined as progression to total hip arthroplasty (THA). Negative predictive factors were analysed. Secondary outcome measures of interest were survivorship to further (non-arthroplasty) surgery, functional outcomes as reflected by patient reported outcome measure scores (PROMS) scores, and whether a learning curve could be identified. Results: The final cohort consisted of 131 females and 110 males, with a mean age of 34 years. There was an overall native hip joint survival rate of 85.4% at ten years. Those who underwent a THA were significantly older at initial surgery, had radiographic evidence of preoperative osteoarthritis and pre- and post-operative acetabular undercoverage. In those whom had not progressed to THA, the average Non-arthritic Hip Score and Oxford Hip Score at ten year follow-up were 72.3% and 36/48, respectively, and 84% still deemed their surgery worthwhile. A learning curve was found to exist that was predicated on case selection rather than surgical technique. Conclusion: This is only the second study to evaluate the long-term outcomes (beyond ten years) of SHD for FAI and the first outside the originating centre. Our results suggest that, with correct patient selection, this remains an operation with worthwhile outcomes at ten years. How the results of open surgery compared to those of arthroscopy remains to be answered. While these results precede the advent of collison software modelling tools, this data helps set a benchmark for future comparison of other techniques effectiveness at the ten year mark.Keywords: femoroacetabular impingement, hip pain, surgical hip dislocation, hip debridement
Procedia PDF Downloads 848918 3D Biomechanics Analysis of Tennis Elbow Factors & Injury Prevention Using Computer Vision and AI
Authors: Aaron Yan
Abstract:
Tennis elbow has been a leading injury and problem among amateur and even professional players. Many factors contribute to tennis elbow. In this research, we apply state of the art sensor-less computer vision and AI technology to study the biomechanics of a player’s tennis movements during training and competition as they relate to the causes of tennis elbow. We provide a framework for the analysis of key biomechanical parameters and their correlations with specific tennis stroke and movements that can lead to tennis elbow or elbow injury. We also devise a method for using AI to automatically detect player’s forms that can lead to tennis elbow development for on-court injury prevention.Keywords: Tennis Elbow, Computer Vision, AI, 3DAT
Procedia PDF Downloads 468917 Comparison of Intraocular Pressure Measurement Prior and Following Full Intracorneal Ring Implantation in Patient with Keratoconus by Three Different Instruments
Authors: Seyed Aliasghar Mosavi, Mostafa Naderi, Khosrow Jadidi, Amir Hashem Mohammadi
Abstract:
To study the measurement of intraocular pressure (IOP) before and after implantation of intrastromal corneal ring (MyoRing) in patients with keratoconus. Setting: Baqiyatallah University of Medical Sciences, Tehran, Iran. Methods: We compared the IOP of 13 eyes which underwent MyoRing implantation prior and six months post operation using Goldman applanation (as gold standard), Icare, and Corvis ST (uncorrected, corrected and corrected with cornea biomechanics). Results: The resulting intraocular pressure measurements prior to surgery, Icare, Corvis (corrected with cornea biomechanics) overestimated the IOP, however measurements by Corvis uncorrected underestimate the IOP. The resulting intraocular pressure measurements after surgery, Icare, Corvis (corrected with cornea biomechanics) overestimated the IOP but measurements by Corvis uncorrected underestimate the IOP. Conclusion: Consistent intraocular pressure measurements on eyes with Myoring in keratoconus can be obtained with the Goldman applanation tonometer as the gold standard measurement. We were not able to obtain consistent results when we measured the IOP by Icare and Corvis prior and after surgery.Keywords: intraocular pressure, MyoRing, Keratoconus, Goldmann applanation, Icare, Corvis ST
Procedia PDF Downloads 2438916 Effect of Institution Volume on Mortality and Outcomes in Osteoporotic Hip Fracture Care
Authors: J. Milton, C. Uzoigwe, O. Ayeko, B. Offorha, K. Anderson, R. G. Middleton
Abstract:
Background: We used the UK National Hip Fracture database to determine the effect of institution hip fracture case volume on hip fracture healthcare outcomes in 2019. Using logistic regression for each healthcare outcome, we compared the best performing 50 units with the poorest performing 50 units in order to determine if the unit volume was associated with performance for each particular outcome. Method: We analysed 175 institutions treating a total of 67,673 patients over the course of a year. Results: The number of hip fractures seen per unit ranged between 86 and 952. Larger units tendered to perform health assessments more consistently and mobilise patients more expeditiously post-operatively. Patients treated at large institutions had shorter lengths of stay. With regard to most other outcomes, there was no association between unit case volume and performance, notably compliance with the Best Practice Tariff, time to surgery, proportion of eligible patients undergoing total hip arthroplasty, length of stay, delirium risk, and pressure sore risk assessments. Conclusion: There is no relationship between unit volume and the majority of health care outcomes. It would seem that larger institutions tend to perform better at parameters that are dependent upon personnel numbers. However, where the outcome is contingent, even partially, on physical infrastructure capacity, there was no difference between larger and smaller units.Keywords: institution volume, mortality, neck of femur fractures, osteoporosis
Procedia PDF Downloads 968915 New Thromboprophylaxis Regime for Knee Arthroplasties
Authors: H. Noureddine, P. Rao, R. Guru, A. Chandratreya
Abstract:
The nice guidance for elective total knee replacements states that patients should be given mechanical thrombo-prophylaxis, and if no contraindications chemical thromboprophylaxis in the form of Dabigatran etexilate, Rivaroxiban, UFH, LMWH, or Fondaparinux sodium (CG92, 1.5.14, January 2010). In Practice administering oral agents has been the dominant practice as it reduces the nursing needs, and shortens hospital stay and is generally received better by patients. However, there are well documented associated bleeding risks, and their effects are difficult to reverse in case of major bleeding. Our experience with oral factor 10 inhibitors used for thromboprophylaxis was marked with several patients developing complications necessitating return to the theatre for wound washouts. This has led us to try a different protocol for thromboprophylaxis that we applied on our patients undergoing total and unicondylar knee replacements. We applied mechanical thromboprophylaxis in the form of intermittent pneumatic pressure devices, and chemical thromboprophylaxis in the form of a dose of prophylactic LMWH pre-op, then 150 mg of Aspirin to start 24 hours after the surgery and to continue for 6 weeks, alongside GI cover with PPIs or antihistamines. We also administered local anaesthetics intra-operatively in line with the ERAS protocol thus encouraging early mobilization. We have identified a cohort of 133 patients who underwent one of the aforementioned procedures in the same trust, and by the same surgeon, where this protocol was applied and examined their medical notes retrospectively with a mean follow-up period of 14 months, to identify the rate and percentage of patients who had thrombo-embolic events in the post-operative period.Keywords: aspirin, heparin, knee arthroplasty, thromboprophylaxis
Procedia PDF Downloads 3698914 Biomechanics of Atalantoaxial Complex for Various Posterior Fixation Techniques
Authors: Arun C. O., Shrijith M. B., Thakur Rajesh Singh
Abstract:
The study aims to analyze and understand the biomechanical stability of the atlantoaxial complex under different posterior fixation techniques using the finite element method in the Indian context. The conventional cadaveric studies performed show heterogeneity in biomechanical properties. The finite element method being a versatile numerical tool, is being wisely used for biomechanics analysis of atlantoaxial complex. However, the biomechanics of posterior fixation techniques for an Indian subject is missing in the literature. It is essential to study in this context as the bone density and geometry of vertebrae vary from region to region, thereby requiring different screw lengths and it can affect the range of motion(ROM), stresses generated. The current study uses CT images for developing a 3D finite element model with C1-C2 geometry without ligaments. Instrumentation is added to this geometry to develop four models for four fixation techniques, namely C1-C2 TA, C1LM-C2PS, C1LM-C2Pars, C1LM-C2TL. To simulate Flexion, extension, lateral bending, axial rotation, 1.5 Nm is applied to C1 while the bottom nodes of C2 are fixed. Then Range of Motion (ROM) is compared with the unstable model(without ligaments). All the fixation techniques showed more than 97 percent reduction in the Range of Motion. The von-mises stresses developed in the screw constructs are obtained. From the studies, it is observed that Transarticular technique is most stable in Lateral Bending, C1LM-C2 Translaminar is found most stable in Flexion/extension. The Von-Mises stresses developed minimum in Trasarticular technique in lateral bending and axial rotation, whereas stress developed in C2 pars construct minimum in Flexion/ Extension. On average, the TA technique is stable in all motions and also stresses in constructs are less in TA. Tarnsarticular technique is found to be the best fixation technique for Indian subjects among the 4 methods.Keywords: biomechanics, cervical spine, finite element model, posterior fixation
Procedia PDF Downloads 1438913 Esports: A Biomechanics and Performance Perspective
Authors: Alex S. Talan
Abstract:
The introduction of scientific terms for esports can directly affect the quality of the training process. This is a critically important scientific task since esports is a rapidly developing global sport that has only recently begun to receive scientific and methodological consideration. In this report, we evaluate esports from a biomechanical perspective. First, we examine the relationship between physical performance and esports gaming techniques, with consideration toward engineering more effective physical and in-game training methodologies for amateur and professional esports competitors. In addition, we advocate that applying biomechanical research methodologies has the added potential to improve physical performance and endurance in esports athletes. With the budding attention on the esports enterprise globally, scientific research into esports would benefit from standardizing terminologies and methodological approaches that are specifically tailored to assess esports training efficacy to enhance individual and team performance within the esports community.Keywords: cybersport, esports, biomechanics, sports technique, training standards, dental occlusion, sports engineering, sitting pose
Procedia PDF Downloads 878912 Development and Validation of Work Movement Task Analysis: Part 1
Authors: Mohd Zubairy Bin Shamsudin
Abstract:
Work-related Musculoskeletal Disorder (WMSDs) is one of the occupational health problems encountered by workers over the world. In Malaysia, there is increasing in trend over the years, particularly in the manufacturing sectors. Current method to observe workplace WMSDs is self-report questionnaire, observation and direct measurement. Observational method is most frequently used by the researcher and practitioner because of the simplified, quick and versatile when it applies to the worksite. However, there are some limitations identified e.g. some approach does not cover a wide spectrum of biomechanics activity and not sufficiently sensitive to assess the actual risks. This paper elucidates the development of Work Movement Task Analysis (WMTA), which is an observational tool for industrial practitioners’ especially untrained personnel to assess WMSDs risk factors and provide a basis for suitable intervention. First stage of the development protocol involved literature reviews, practitioner survey, tool validation and reliability. A total of six themes/comments were received in face validity stage. New revision of WMTA consisted of four sections of postural (neck, back, shoulder, arms, and legs) and associated risk factors; movement, load, coupling and basic environmental factors (lighting, noise, odorless, heat and slippery floor). For inter-rater reliability study shows substantial agreement among rater with K = 0.70. Meanwhile, WMTA validation shows significant association between WMTA score and self-reported pain or discomfort for the back, shoulder&arms and knee&legs with p<0.05. This tool is expected to provide new workplace ergonomic observational tool to assess WMSDs for the next stage of the case study.Keywords: assessment, biomechanics, musculoskeletal disorders, observational tools
Procedia PDF Downloads 4698911 The Affect of Total Quality Management on Firm's Innovation Performance: A Literature Review
Authors: Omer Akkaya, Nurullah Ekmekcı, Muammer Zerenler
Abstract:
Innovation for businesses means a new product and service and sometimes a new implementation. Total Quality Management is a management philosophy which focus on customer, process and system.There is a certain relationship between principles of Total Quality Management and innovation performance. Main aim of this study is to show how the implementation and principles of Total Quality Management (TQM) affect a firm's innovation performance. Also, this paper discusses positive and negative affects of Total Quality Management on innovation performance and demonstrates some examples.Keywords: innovation, innovation types, total quality management, principles of total quality management
Procedia PDF Downloads 6308910 Vancomycin Resistance Enterococcus and Implications to Trauma and Orthopaedic Care
Authors: O. Davies, K. Veravalli, P. Panwalkar, M. Tofighi, P. Butterick, B. Healy, A. Mofidi
Abstract:
Vancomycin resistant enterococcus infection is a condition that usually impacts ICUs, transplant, dialysis, and cancer units, often as a nosocomial infection. After an outbreak in the acute trauma and orthopaedic unit in Morriston hospital, we aimed to access the conditions that predispose VRE infections in our unit. Thirteen cases of VRE infection and five cases of VRE colonisations were identified in patients who were treated for orthopaedic care between 1/1/2020 and 1/11/2021. Cases were reviewed to identify predisposing factors, specifically looking at age, presenting condition and treatment, presence of infection and antibiotic care, active haemo-oncological condition, long term renal dialysis, previous hospitalisation, VRE predisposition, and clearance (PREVENT) scores, and outcome of care. The presenting condition, treatment, presence of postoperative infection, VRE scores, age was compared between colonised and the infected cohort. VRE type in both colonised and infection group was Enterococcus Faecium in all but one patient. The colonised group had the same age (T=0.6 P>0.05) and sex (2=0.115, p=0.74), presenting condition and treatment which consisted of peri-femoral fixation or arthroplasty in all patients. The infected group had one case of myelodysplasia and four cases of chronic renal failure requiring dialysis. All of the infected patient had sustained an infected complication of their fracture fixation or arthroplasty requiring reoperation and antibiotics. The infected group had an average VRE predisposition score of 8.5 versus the score of 3 in the colonised group (F=36, p<0.001). PREVENT score was 7 in the infected group and 2 in the colonised group(F=153, p<0.001). Six patients(55%) succumbed to their infection, and one VRE infection resulted in limb loss. In the orthopaedic cohort, VRE infection is a nosocomial condition that has peri-femoral predilection and is seen in association with immunosuppression or renal failure. The VRE infection cohort has been treated for infective complication of original surgery weeks prior to VRE infection. Based on our findings, we advise avoidance of infective complications, change of practice in use of antibiotics and use radical surgery and surveillance for VRE infections beyond infective precautions. PREVENT score shows that the infected group are unlikely to clear their VRE in the future but not the colonised group.Keywords: surgical site infection, enterococcus, orthopaedic surgery, vancomycin resistance
Procedia PDF Downloads 1488909 Viscoelastic Response of the Human Corneal Stroma Induced by Riboflavin/UVA Cross-Linking
Authors: C. Labate, M. P. De Santo, G. Lombardo, R. Barberi, M. Lombardo, N. M. Ziebarth
Abstract:
In the past decades, the importance of corneal biomechanics in the normal and pathological functions of the eye has gained its credibility. In fact, the mechanical properties of biological tissues are essential to their physiological function. We are convinced that an improved understanding of the nanomechanics of corneal tissue is important to understand the basic molecular interactions between collagen fibrils. Ultimately, this information will help in the development of new techniques to cure ocular diseases and in the development of biomimetic materials. Therefore, nanotechnology techniques are powerful tools and, in particular, Atomic Force Microscopy has demonstrated its ability to reliably characterize the biomechanics of biological tissues either at the micro- or nano-level. In the last years, we have investigated the mechanical anisotropy of the human corneal stroma at both the tissue and molecular levels. In particular, we have focused on corneal cross-linking, an established procedure aimed at slowing down or halting the progression of the disease known as keratoconus. We have obtained the first evidence that riboflavin/UV-A corneal cross-linking induces both an increase of the elastic response and a decrease of the viscous response of the most anterior stroma at the scale of stromal molecular interactions.Keywords: atomic force spectroscopy, corneal stroma, cross-linking, viscoelasticity
Procedia PDF Downloads 3128908 The Impact of a Gait Assessment Model on Learning Outcomes
Authors: Seema Saini, Arsh Shikalgar, Neelam Tejani, Tushar J. Palekar
Abstract:
This study introduces and evaluates a gait assessment system device as an educational model for healthcare students. The system aims to enhance learning through active experimentation with educators, focusing on teaching fundamental concepts like torque, potential energy, and kinetic movements. A total of 80 fourth-year healthcare students specializing in physiotherapy participated in this study. The study utilized a pre-post multiple-choice question (MCQ) examination format to evaluate the student's learning outcomes. Post-test performance significantly improved compared to pre-test scores (mean difference p<0.001, t=5.96). Participants reported that the gait assessment model effectively aided in achieving learning objectives, increasing topic understanding and interest, and enhancing comprehension of biomechanical events in gait.Keywords: biomechanics, educational innovation, interactive learning, healthcare education
Procedia PDF Downloads 208907 Inertial Motion Capture System for Biomechanical Analysis in Rehabilitation and Sports
Authors: Mario Sandro F. Rocha, Carlos S. Ande, Anderson A. Oliveira, Felipe M. Bersotti, Lucas O. Venzel
Abstract:
The inertial motion capture systems (mocap) are among the most suitable tools for quantitative clinical analysis in rehabilitation and sports medicine. The inertial measuring units (IMUs), composed by accelerometers, gyroscopes, and magnetometers, are able to measure spatial orientations and calculate displacements with sufficient precision for applications in biomechanical analysis of movement. Furthermore, this type of system is relatively affordable and has the advantages of portability and independence from external references. In this work, we present the last version of our inertial motion capture system, based on the foregoing technology, with a unity interface designed for rehabilitation and sports. In our hardware architecture, only one serial port is required. First, the board client must be connected to the computer by a USB cable. Next, an available serial port is configured and opened to establish the communication between the client and the application, and then the client starts scanning for the active MOCAP_S servers around. The servers play the role of the inertial measuring units that capture the movements of the body and send the data to the client, which in turn create a package composed by the ID of the server, the current timestamp, and the motion capture data defined in the client pre-configuration of the capture session. In the current version, we can measure the game rotation vector (grv) and linear acceleration (lacc), and we also have a step detector that can be abled or disabled. The grv data are processed and directly linked to the bones of the 3D model, and, along with the data of lacc and step detector, they are also used to perform the calculations of displacements and other variables shown on the graphical user interface. Our user interface was designed to calculate and present variables that are important for rehabilitation and sports, such as cadence, speed, total gait cycle, gait cycle length, obliquity and rotation, and center of gravity displacement. Our goal is to present a low-cost portable and wearable system with a friendly interface for application in biomechanics and sports, which also performs as a product of high precision and low consumption of energy.Keywords: biomechanics, inertial sensors, motion capture, rehabilitation
Procedia PDF Downloads 1408906 Comparing the Knee Kinetics and Kinematics during Non-Steady Movements in Recovered Anterior Cruciate Ligament Injured Badminton Players against an Uninjured Cohort: Case-Control Study
Authors: Anuj Pathare, Aleksandra Birn-Jeffery
Abstract:
Background: The Anterior Cruciate Ligament(ACL) helps stabilize the knee joint minimizing tibial anterior translation. Anterior Cruciate Ligament (ACL) injury is common in racquet sports and often occurs due to sudden acceleration, deceleration or changes of direction. This mechanism in badminton most commonly occurs during landing after an overhead stroke. Knee biomechanics during dynamic movements such as walking, running and stair negotiation, do not return to normal for more than a year after an ACL reconstruction. This change in the biomechanics may lead to re-injury whilst performing non-steady movements during sports, where these injuries are most prevalent. Aims: To compare if the knee kinetics and kinematics in ACL injury recovered athletes return to the same level as those from an uninjured cohort during standard movements used for clinical assessment and badminton shots. Objectives: The objectives of the study were to determine: Knee valgus during the single leg squat, vertical drop jump, net shot and drop shot; Degree of internal or external rotation during the single leg squat, vertical drop jump, net shot and drop shot; Maximum knee flexion during the single leg squat, vertical drop jump and net shot. Methods: This case-control study included 14 participants with three ACL injury recovered athletes and 11 uninjured participants. The participants performed various functional tasks including vertical drop jump, single leg squat; the forehand net shot and the forehand drop shot. The data was analysed using the two-way ANOVA test, and the reliability of the data was evaluated using the Intra Class Coefficient. Results: The data showed a significant decrease in the range of knee rotation in ACL injured participants as compared to the uninjured cohort (F₇,₅₅₆=2.37; p=0.021). There was also a decrease in the maximum knee flexion angles and an increase in knee valgus angles in ACL injured participants although they were not statistically significant. Conclusion: There was a significant decrease in the knee rotation angles in the ACL injured participants which could be a potential cause for re-injury in these athletes in the future. Although the results for decrease in maximum knee flexion angles and increase in knee valgus angles were not significant, this may be due to a limited sample of ACL injured participants; there is potential for it to be identified as a variable of interest in the rehabilitation of ACL injuries. These changes in the knee biomechanics could be vital in the rehabilitation of ACL injured athletes in the future, and an inclusion of sports based tasks, e.g., Net shot along with standard protocol movements for ACL assessment would provide a better measure of the rehabilitation of the athlete.Keywords: ACL, biomechanics, knee injury, racquet sport
Procedia PDF Downloads 1748905 Altered Lower Extremity Biomechanical Risk Factor Related to Anterior Cruciate Ligament Injury in Athlete with Functional Ankle Instability
Authors: Mohammad Karimizadehardakani, Hooman Minoonejad, Reza Rajabi, Ali Sharifnejad
Abstract:
Background: Ankle sprain is one of the most important risk factor of anterior cruciate ligament (ACL) injury. Also, functional ankle instability (FAI) population has alterations in lower extremity sagittal plane biomechanics during landing task. We want to examine whether biomechanical alterations demonstrated by FAI patients are associated with the mechanism of ACL injury during high risk and sport related tasks. Methods: Sixteen basketball player with FAI and 16 non-injured control performed a single-leg cross drop landing. Knee sagittal and frontal (ATSF) was calculated. Independent t-tests, multiple linear regression, and Pearson correlation were used for analysis data. Result: Subject with FAI showed more peak ATFS, posterior ground reaction force (GRF) and less knee flexion, compared to the controls (P= 0.001, P= 0.004, P= 0.011). Knee flexion (r= −0.824, P = 0.011) and posterior GRF (r= 0.901, P = .001) were correlated with ATSF; Posterior GRF was factor that most explained the variance in ATSF (R2= 0.645; P = .001) in the FAI group. Conclusions: Result of our study showed there is a potential biomechanical relationship between the presence of FAI and risk factors associated with ACL injury mechanism.Keywords: functional ankle instability, anterior cruciate ligament, biomechanics, risk factor
Procedia PDF Downloads 2228904 Review and Analyze on the Journal of Sport Science
Authors: Zhan Dong, Qiu Jianrong, Li Qinghui, Zhang Lei
Abstract:
The quantity and quality of the papers published on sport science from 2001 to 2013 had been counted and analysed and compared with the papers published on the journal from 1990 to 2000. The result showed that: 1. In the sports medicine field, the proportion of basic/application was abnormal. Basic research was far more than the application research. The papers on researching of imitating altitude training was the main part. Gene research made great progress.The research on sport injury and medical supervision were lower and lower. Research on sports prescription had made much progress, especially in the patients of heart infarction. 2. In building up people’s health field, the research on the old people had been more and more compared with the 10 years before, but it was not enough. 3. In the field of sports psychology, the research on disable people had been more compared with the 10 years before. Solved the problem of the sportmen before the game. 4. In the field of sports biomechanics, it showed that methods had made great progress compared with the 10 years before. Sport biomechanics combined with sports medicine, helped the sportsmen in good condition in the game. 5. In the exercise training field, the experts pay more attention to the outstanding sportsmen, and the researches emphasized that biology knowledge is the main basic for them to the research.Keywords: sport medicine, sport injury, medical supervision
Procedia PDF Downloads 4958903 WILCKO-PERIO, Periodontally Accelerated Orthodontics
Authors: Kruttika Bhuse
Abstract:
Aim: Synergism between periodontists and orthodontists (periodontal accelerated osteogenic orthodontics- PAOO) creates crucial opportunities to enhance clinical outcomes of combined therapies regarding both disciplines and has made adult orthodontics a reality. Thus, understanding the biomechanics of bone remodelling may increase the clinical applications of corticotomy facilitated orthodontics with or without alveolar augmentation. Wilckodontics can be an attractive treatment option and be a “win-win” situation for both the dental surgeon and patient by reducing the orthodontic treatment time in adults. Materials and methods: In this review, data related to the clinical aspects, steps of procedure, biomechanics of bone, indications and contraindications and final outcome of wilckodontic shall be discussed. 50 supporting articles from various international journals and 70 clinical cases were reviewed to get a better understanding to design this wilckodontic - meta analysis. Various journals like the Journal Of Clinical And Diagnostic Research, Journal Of Indian Society Of Periodontology, Journal Of Periodontology, Pubmed, Boston Orthodontic University Journal, Good Practice Orthodontics Volume 2, have been referred to attain valuable information on wilckodontics which was then compiled in this single review study. Result: As a promising adjuvant technique based on the transient nature of demineralization-remineralisation process in healthy tissues, wilckodontics consists of regional acceleratory phenomenon by alveolar corticotomy and bone grafting of labial and palatal/lingual surfaces, followed by orthodontic force. The surgical wounding of alveolar bone potentiates tissue reorganization and healing by a way of transient burst of localized hard and soft tissue remodelling.This phenomenon causes bone healing to occur 10-50 times faster than normal bone turnover. Conclusion: This meta analysis helps understanding that the biomechanics of bone remodelling may increase the clinical applications of corticotomy facilitated orthodontics with or without alveolar augmentation. The main benefits being reduced orthodontic treatment time, increased bone volume and post-orthodontic stability.Keywords: periodontal osteogenic accelerated orthodontics, alveolar corticotomy, bone augmentation, win-win situation
Procedia PDF Downloads 3918902 The Effects of Extracorporeal Shock Wave Therapy on Plantar Pressure in Patients with Calcaneal Spur
Authors: Zehra Betül Karakoç
Abstract:
Aim: The aim of our study is to determine the changement pf plantar pressure after extracorporeal shock wave therapy (ESWT) in a patient with calcaneal spur (CS). Method: Thirty patients with CS who received ESWT treatment at Kartal Yavuz Selim State Hospital between May 2020 and November 2022 participated in this study. Demographic information of the cases was obtained. Pain levels and plantar pressure were measured with Visuel Analog Scale (VAS) and pedobarography, respectively. Pedobarography measured the maximal strength, peak pressure level, and contact area values of the hind, middle, forefoot, and toes. The cases were re-evaluated 4 weeks after the application of 15 Hz, 2-3 bar, 2,000 beats ESWT for 3 sessions. 22 cases participated in the second evaluation. The data of all patients were evaluated bilaterally. Results: Pain intensity levels after treatment were statistically significantly decreased compared to before treatment (p=0.012). Maximum force and contact area values of total foot and forefoot increased significantly (p < 0.05). Conclusion: We consider that the increased max force value of total foot and forefoot area after ESWT is due to the normal walking rate gained related to decreased pain. ESWT treatment may have positive effects on foot pressure distribution and body biomechanics. In order to interpret the results of our study more clearly, randomized controlled studies with a larger number of cases were planned in the future.Keywords: calcaneal spur, ESWT, plantar pressure, pain
Procedia PDF Downloads 728901 A Literature Review of Ergonomics Sitting Studies to Characterize Safe and Unsafe Sitting Behaviors
Authors: Yoonjin Lee, Dongwook Hwang, Juhee Park, Woojin Park
Abstract:
As undesirable sitting posture is known to be a major cause of musculoskeletal disorder of office workers, sitting has attracted attention on occupational health. However, there seems to be no consensus on what are safe and unsafe sitting behaviors. The purpose of this study was to characterize safe and unsafe behaviors based on scientific findings of sitting behavior. Three objectives were as follows; to identify different sitting behaviors measure used in ergonomics studies on safe sitting, for each measure identified, to find available findings or recommendations on safe and unsafe sitting behaviors along with relevant empirical grounds, and to synthesize the findings or recommendations to provide characterizations of safe and unsafe behaviors. A systematic review of electronic databases (Google Scholar, PubMed, Web of Science) was conducted for extensive search of sitting behavior. Key terms included awkward sitting position, sedentary sitting, dynamic sitting, sitting posture, sitting posture, and sitting biomechanics, etc. Each article was systemically abstracted to extract a list of studied sitting behaviors, measures used to study the sitting behavior, and presence of empirical evidence of safety of the sitting behaviors. Finally, characterization of safe and unsafe sitting behavior was conducted based on knowledge with empirical evidence. This characterization is expected to provide useful knowledge for evaluation of sitting behavior and about postures to be measured in development of sensing chair.Keywords: sitting position, sitting biomechanics, sitting behavior, unsafe sitting
Procedia PDF Downloads 3028900 Comparing Implications of Manual and ROSA-assisted Total Knee Replacements on Patients and Physicians: A Scoping Review
Authors: Bassem M. Darwish, Robert H. Ablove
Abstract:
Introduction: Total knee arthroscopy (TKA) is a commonly performed procedure in patients with end-stage osteoarthritis and inaccuracy of component alignment in TKA has been shown to have many adverse post-operative outcomes such as accelerated implant wear, reduced functional outcomes, and shorter overall implant survival. Robotic surgical systems have been introduced to try and improve joint alignment and functional outcomes in knee arthroscopy, one recent iteration is the ROSA knee system, released to the market in 2019. The objective of this scoping review is to map the available evidence, identify the current types of evidence, and identify knowledge gaps to guide future studies on patient outcomes following ROSA-assisted total knee arthroplasties. Methods: An electronic search was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) extension for scoping reviews. Search terms included ROSA, knee arthroscopy, osteoarthritis, robotic, and malalignment. Types of study participants included patients with osteoarthritis, ages 18 and older, male or female, who received manual TKA (mTKA) or ROSA-assisted TKA (rTKA), and human patients or cadavers. Published, peer-reviewed controlled trials, observational studies, and case series were included. Case reports were not included in article review. Resulting articles were first screened based on title and abstract. Articles meeting inclusion criteria based on title and abstract review then underwent full-text review by the same reviewer. Results: This scoping review identified 11 total studies, 3 prospective observational studies, and 8 retrospective observational studies - a total of 970 rTKA patients and 1745 mTKA patients. There were no case series or randomized controlled trials comparing rTKA and mTKA. Patient-centered outcomes showed promise for rTKA, where it frequently showed significantly favorable functional outcomes, measured via KOOS-JR, VAS, KSS, OKS, FJS, and PROMIS scores, at various times postoperatively. However, there was much discrepancy about which score yielded significance at which postoperative follow-up. Complication rates, reoperation rates, and LOS were very similar between mTKA and rTKA groups. Studies also showed rTKA had more accurate joint alignment within the 0 ± 3o corridor and had significantly higher rates of achieving postoperative joint angles similar to the preoperative plan. Finally, there was major agreement that rTKA cases take significantly longer time at the start, however, there is a rapid learning curve. Once past the learning curve, rTKA cases are performed in a similar time to mTKA and reduced physician stress and strain. Conclusion: The ROSA knee system represents a promising option for the management of osteoarthritis via total knee arthroscopy. The studies reviewed in this paper favor the patient-centered function outcomes, joint alignments, and physician health implications of the ROSA knee system to conventional total knee arthroscopy. Further study is warranted, however, to better understand recovery periods, longer-term functional outcomes, operative fatigue, and reduction in radiation exposure.Keywords: arthroplasty, knee, robotics, malalignment
Procedia PDF Downloads 278899 Examination of Porcine Gastric Biomechanics in the Antrum Region
Authors: Sif J. Friis, Mette Poulsen, Torben Strom Hansen, Peter Herskind, Jens V. Nygaard
Abstract:
Gastric biomechanics governs a large range of scientific and engineering fields, from gastric health issues to interaction mechanisms between external devices and the tissue. Determination of mechanical properties of the stomach is, thus, crucial, both for understanding gastric pathologies as well as for the development of medical concepts and device designs. Although the field of gastric biomechanics is emerging, advances within medical devices interacting with the gastric tissue could greatly benefit from an increased understanding of tissue anisotropy and heterogeneity. Thus, in this study, uniaxial tensile tests of gastric tissue were executed in order to study biomechanical properties within the same individual as well as across individuals. With biomechanical tests in the strain domain, tissue from the antrum region of six porcine stomachs was tested using eight samples from each stomach (n = 48). The samples were cut so that they followed dominant fiber orientations. Accordingly, from each stomach, four samples were longitudinally oriented, and four samples were circumferentially oriented. A step-wise stress relaxation test with five incremental steps up to 25 % strain with 200 s rest periods for each step was performed, followed by a 25 % strain ramp test with three different strain rates. Theoretical analysis of the data provided stress-strain/time curves as well as 20 material parameters (e.g., stiffness coefficients, dissipative energy densities, and relaxation time coefficients) used for statistical comparisons between samples from the same stomach as well as in between stomachs. Results showed that, for the 20 material parameters, heterogeneity across individuals, when extracting samples from the same area, was in the same order of variation as the samples within the same stomach. For samples from the same stomach, the mean deviation percentage for all 20 parameters was 21 % and 18 % for longitudinal and circumferential orientations, compared to 25 % and 19 %, respectively, for samples across individuals. This observation was also supported by a nonparametric one-way ANOVA analysis, where results showed that the 20 material parameters from each of the six stomachs came from the same distribution with a level of statistical significance of P > 0.05. Direction-dependency was also examined, and it was found that the maximum stress for longitudinal samples was significantly higher than for circumferential samples. However, there were no significant differences in the 20 material parameters, with the exception of the equilibrium stiffness coefficient (P = 0.0039) and two other stiffness coefficients found from the relaxation tests (P = 0.0065, 0.0374). Nor did the stomach tissue show any significant differences between the three strain-rates used in the ramp test. Heterogeneity within the same region has not been examined earlier, yet, the importance of the sampling area has been demonstrated in this study. All material parameters found are essential to understand the passive mechanics of the stomach and may be used for mathematical and computational modeling. Additionally, an extension of the protocol used may be relevant for compiling a comparative study between the human stomach and the pig stomach.Keywords: antrum region, gastric biomechanics, loading-unloading, stress relaxation, uniaxial tensile testing
Procedia PDF Downloads 4308898 Effect of Nitrogen Management on Nitrogen Uptake, Dry Matter Production and Some Yield Parameters
Authors: Mandana Tayefe, Ebrahim Amiri, Azin Nasrollah Zade
Abstract:
Effect of nitrogen (N) fertilizer levels on nitrogen uptake, dry matter production, yield and some yield components of rice (Hashemi, Kazemi, Khazar) was investigated in an experiment as factorial in RCBD with 3 replications in a paddy light soil at Guilan province, Iran, 2008-2009. In this experiment, four treatments including: N1-control (no N fertilizer); N2- 30 kgN/ha; N3- 60 kgN/ha; N4- 90 kgN/ha were compared. Results showed that total biomass (8386 kg/ha), grain yield (3662 kg/ha), panicles m-2 (235.8) and total grain per panicle (103.8) were reached the highest value at high nitrogen level. Among the varieties the highest total biomass (7734 kg/ha), grain yield (3414 kg/ha) and total grain per panicle (78.2) belonged to Khazar. Dry matter, total N uptake was varied in different cultivars significantly and Khazar variety had the highest contents. Total biomass and total N uptake was varied significantly with the increasement of the amount of nitrogen applied. As total biomass and total N uptake increased with increasing in N fertilizing.Keywords: rice, nitrogen, nitrogen uptake, dry matter
Procedia PDF Downloads 4148897 Seasonal Influence on Environmental Indicators of Beach Waste
Authors: Marcus C. Garcia, Giselle C. Guimarães, Luciana H. Yamane, Renato R. Siman
Abstract:
The environmental indicators and the classification of beach waste are essential tools to diagnose the current situation and to indicate ways to improve the quality of this environment. The purpose of this paper was to perform a quali-quantitative analysis of the beach waste on the Curva da Jurema Beach (Espírito Santo - Brazil). Three transects were used with equidistant positioning over the total length of the beach for the solid waste collection. Solid wastes were later classified according to their use and primary raw material from the low and high summer season. During the low season, average values of 7.10 items.m-1, 18.22 g.m-1 and 0.91 g.m-2 were found for the whole beach, and transect 3 contributed the most waste, with the total sum of items equal to 999 (49%), a total mass of 5.62 kg and a total volume of 21.31 L. During the high summer season, average values of 8.22 items.m-1, 54.40 g.m-1 and 2.72 g.m-2 were found, with transect 2 contributing the most to the total sum with 1,212 items (53%), a total mass of 10.76 kg and a total volume of 51.99 L. Of the total collected, plastic materials represented 51.4% of the total number of items, 35.9% of the total mass and 68% of the total volume. The implementation of reactive and proactive measures is necessary so that the management of the solid wastes on Curva da Jurema Beach is in accordance with principles of sustainability.Keywords: beach solid waste, environmental indicators, quali-quantitative analysis, waste management
Procedia PDF Downloads 3068896 Biomechanical Study of a Type II Superior Labral Anterior to Posterior Lesion in the Glenohumeral Joint Using Finite Element Analysis
Authors: Javier A. Maldonado E., Duvert A. Puentes T., Diego F. Villegas B.
Abstract:
The SLAP lesion (Superior Labral Anterior to Posterior) involves the labrum, causing pain and mobility problems in the glenohumeral joint. This injury is common in athletes practicing sports that requires throwing or those who receive traumatic impacts on the shoulder area. This paper determines the biomechanical behavior of soft tissues of the glenohumeral joint when type II SLAP lesion is present. This pathology is characterized for a tear in the superior labrum which is simulated in a 3D model of the shoulder joint. A 3D model of the glenohumeral joint was obtained using the free software Slice. Then, a Finite Element analysis was done using a general purpose software which simulates a compression test with external rotation. First, a validation was done assuming a healthy joint shoulder with a previous study. Once the initial model was validated, a lesion of the labrum built using a CAD software and the same test was done again. The results obtained were stress and strain distribution of the synovial capsule and the injured labrum. ANOVA was done for the healthy and injured glenohumeral joint finding significant differences between them. This study will help orthopedic surgeons to know the biomechanics involving this type of lesion and also the other surrounding structures affected by loading the injured joint.Keywords: biomechanics, computational model, finite elements, glenohumeral joint, superior labral anterior to posterior lesion
Procedia PDF Downloads 2088895 Thermography Evaluation on Facial Temperature Recovery after Elastic Gum
Authors: A. Dionísio, L. Roseiro, J. Fonseca, P. Nicolau
Abstract:
Thermography is a non-radiating and contact-free technology which can be used to monitor skin temperature. The efficiency and safety of thermography technology make it a useful tool for detecting and locating thermal changes in skin surface, characterized by increases or decreases in temperature. This work intends to be a contribution for the use of thermography as a methodology for evaluation of skin temperature in the context of orofacial biomechanics. The study aims to identify the oscillations of skin temperature in the left and right hemiface regions of the masseter muscle, during and after thermal stimulus, and estimate the time required to restore the initial temperature after the application of the stimulus. Using a FLIR T430sc camera, a data acquisition protocol was followed with a group of eight volunteers, aged between 22 and 27 years. The tests were performed in a controlled environment with the volunteers in a comfortably static position. The thermal stimulus involves the use of an ice volume with controlled size and contact surface. The skin surface temperature was recorded in two distinct situations, namely without further stimulus and with the additions of a stimulus obtained by a chewing gum. The data obtained were treated using FLIR Research IR Max software. The time required to recover the initial temperature ranged from 20 to 52 minutes when no stimulus was added and varied between 8 and 26 minutes with the chewing gum stimulus. These results show that recovery is faster with the addition of the stimulus and may guide clinicians regarding the pre and post-operative times with ice therapy, in the presence or absence of mechanical stimulus that increases muscle functions (e.g. phonetics or mastication).Keywords: thermography, orofacial biomechanics, skin temperature, ice therapy
Procedia PDF Downloads 2558894 The Curvature of Bending Analysis and Motion of Soft Robotic Fingers by Full 3D Printing with MC-Cells Technique for Hand Rehabilitation
Authors: Chaiyawat Musikapan, Ratchatin Chancharoen, Saknan Bongsebandhu-Phubhakdi
Abstract:
For many recent years, soft robotic fingers were used for supporting the patients who had survived the neurological diseases that resulted in muscular disorders and neural network damages, such as stroke and Parkinson’s disease, and inflammatory symptoms such as De Quervain and trigger finger. Generally, the major hand function is significant to manipulate objects in activities of daily living (ADL). In this work, we proposed the model of soft actuator that manufactured by full 3D printing without the molding process and one material for use. Furthermore, we designed the model with a technique of multi cavitation cells (MC-Cells). Then, we demonstrated the curvature bending, fluidic pressure and force that generated to the model for assistive finger flexor and hand grasping. Also, the soft actuators were characterized in mathematics solving by the length of chord and arc length. In addition, we used an adaptive push-button switch machine to measure the force in our experiment. Consequently, we evaluated biomechanics efficiency by the range of motion (ROM) that affected to metacarpophalangeal joint (MCP), proximal interphalangeal joint (PIP) and distal interphalangeal joint (DIP). Finally, the model achieved to exhibit the corresponding fluidic pressure with force and ROM to assist the finger flexor and hand grasping.Keywords: biomechanics efficiency, curvature bending, hand functional assistance, multi cavitation cells (MC-Cells), range of motion (ROM)
Procedia PDF Downloads 260