Search results for: finite groups
8797 Comparative Study of Propensity for Amyloidogenesis in Male and Female Mice
Authors: Keivan Jamshidi, Afshin Zahedi
Abstract:
Reactive amyloidosis is a condition that complicates a long list of chronic inflammation, chronic infectious, malignant, and hereditary disorders. In the present study the propensity for amyloidogenesis in male and female rats on spatio-temporal pattern was evaluated. For this purpose a total of 40 male and female Swiss mice, obtained from Pasteur Institute Tehran, after being weighted were randomly divided into 4 groups including 2 treatment groups [ 10 male (Group A1) and 10 female (Group B1) each], and 2 control groups [10 male (Group A2) and 10 female (Group B2) each]. At the end of 3rd, 5th and 7th weeks of experiment 3 mice were randomly selected and euthnised. Spleen samples of each animal were obtained and preserved in 10% neutral buffer formalin. Sample were then processed through different stages of dehydration, clearing and impregnation and finally embedded in paraffin blocks. Sections of 5µm thickness then cut and stained by alkaline Congo red techniques. The data obtained from polarized microscopic quantitative analysis did show significant differences between groups A1 and B1. A preferential expression of reactive amyloidosis is concluded in male, indicating sex differences in amyloidosis.Keywords: amyloidosis, amyloidogenesis, mice, gender
Procedia PDF Downloads 5948796 An Investigation on Electric Field Distribution around 380 kV Transmission Line for Various Pylon Models
Authors: C. F. Kumru, C. Kocatepe, O. Arikan
Abstract:
In this study, electric field distribution analyses for three pylon models are carried out by a Finite Element Method (FEM) based software. Analyses are performed in both stationary and time domains to observe instantaneous values along with the effective ones. Considering the results of the study, different line geometries is considerably affecting the magnitude and distribution of electric field although the line voltages are the same. Furthermore, it is observed that maximum values of instantaneous electric field obtained in time domain analysis are quite higher than the effective ones in stationary mode. In consequence, electric field distribution analyses should be individually made for each different line model and the limit exposure values or distances to residential buildings should be defined according to the results obtained.Keywords: electric field, energy transmission line, finite element method, pylon
Procedia PDF Downloads 7288795 Evaluation of Seismic Behavior of Steel Shear Wall with Opening with Hardener and Beam with Reduced Cross Section under Cycle Loading with Finite Element Analysis Method
Authors: Masoud Mahdavi
Abstract:
During an earthquake, the structure is subjected to seismic loads that cause tension in the members of the building. The use of energy dissipation elements in the structure reduces the percentage of seismic forces on the main members of the building (especially the columns). Steel plate shear wall, as one of the most widely used types of energy dissipation element, has evolved today, and regular drilling of its inner plate is one of the common cases. In the present study, using a finite element method, the shear wall of the steel plate is designed as a floor (with dimensions of 447 × 6/246 cm) with Abacus software and in three different modes on which a cyclic load has been applied. The steel shear wall has a horizontal element (beam) with a reduced beam section (RBS). The hole in the interior plate of the models is created in such a way that it has the process of increasing the area, which makes the effect of increasing the surface area of the hole on the seismic performance of the steel shear wall completely clear. In the end, it was found that with increasing the opening level in the steel shear wall (with reduced cross-section beam), total displacement and plastic strain indicators increased, structural capacity and total energy indicators decreased and the Mises Monson stress index did not change much.Keywords: steel plate shear wall with opening, cyclic loading, reduced cross-section beam, finite element method, Abaqus software
Procedia PDF Downloads 1228794 Finite Difference Modelling of Temperature Distribution around Fire Generated Heat Source in an Enclosure
Authors: A. A. Dare, E. U. Iniegbedion
Abstract:
Industrial furnaces generally involve enclosures of fire typically initiated by the combustion of gases. The fire leads to temperature distribution inside the enclosure. A proper understanding of the temperature and velocity distribution within the enclosure is often required for optimal design and use of the furnace. This study was therefore directed at numerical modeling of temperature distribution inside an enclosure as typical in a furnace. A mathematical model was developed from the conservation of mass, momentum and energy. The stream function-vorticity formulation of the governing equations was solved by an alternating direction implicit (ADI) finite difference technique. The finite difference formulation obtained were then developed into a computer code. This was used to determine the temperature, velocities, stream function and vorticity. The effect of the wall heat conduction was also considered, by assuming a one-dimensional heat flow through the wall. The computer code (MATLAB program) developed was used for the determination of the aforementioned variables. The results obtained showed that the transient temperature distribution assumed a uniform profile which becomes more chaotic with increasing time. The vertical velocity showed increasing turbulent behavior with time, while the horizontal velocity assumed decreasing laminar behavior with time. All of these behaviours were equally reported in the literature. The developed model has provided understanding of heat transfer process in an industrial furnace.Keywords: heat source, modelling, enclosure, furnace
Procedia PDF Downloads 2558793 Vaccination of Algerian Local Rabbits with Precocious Strains of Eimeria magna and Eimeria media
Authors: Mohamed Sadek Bachene, Soraya Temim, Hassina Ainbaziz, Asma Bachene
Abstract:
The present study was conducted to assess the safety and the efficacy of a vaccine containing the Algerian precocious strains of Eimeria magna and Eimeria media used separately or together against rabbit coccidiosis. The samples consisted of 56 young rabbits reared in specific pathogen-free conditions. Following the challenge inoculation, statistically significant decreases in oocyst excretion were noticed in the vaccinated rabbits with the precocious strain of Eimeria magna, Eimeria media, and both species leading toa good immune response acquired by the vaccination associated with a good growth rate. Moreover, there was a statistically significant increase in oocyst output following the challenge in all challenged groups. Unlike the vaccinated groups, the challenged groups showed poor weight gains. More than 50% of the young rabbits from all the challenged groups presented diarrhea. Consequently, these precocious strains constitute good candidates for mono or polyvalent anticoccidial vaccines in the future.Keywords: precocious strain, rabbits, vaccination, wild strain
Procedia PDF Downloads 918792 Development of 3D Particle Method for Calculating Large Deformation of Soils
Authors: Sung-Sik Park, Han Chang, Kyung-Hun Chae, Sae-Byeok Lee
Abstract:
In this study, a three-dimensional (3D) Particle method without using grid was developed for analyzing large deformation of soils instead of using ordinary finite element method (FEM) or finite difference method (FDM). In the 3D Particle method, the governing equations were discretized by various particle interaction models corresponding to differential operators such as gradient, divergence, and Laplacian. The Mohr-Coulomb failure criterion was incorporated into the 3D Particle method to determine soil failure. The yielding and hardening behavior of soil before failure was also considered by varying viscosity of soil. First of all, an unconfined compression test was carried out and the large deformation following soil yielding or failure was simulated by the developed 3D Particle method. The results were also compared with those of a commercial FEM software PLAXIS 3D. The developed 3D Particle method was able to simulate the 3D large deformation of soils due to soil yielding and calculate the variation of normal and shear stresses following clay deformation.Keywords: particle method, large deformation, soil column, confined compressive stress
Procedia PDF Downloads 5728791 Seismic Performance Evaluation of Bridge Structures Using 3D Finite Element Methods in South Korea
Authors: Woo Young Jung, Bu Seog Ju
Abstract:
This study described the seismic performance evaluation of bridge structures, located near Daegu metropolitan city in Korea. The structural design code or regulatory guidelines is focusing on the protection of brittle failure or collapse in bridges’ lifetime during an earthquake. This paper illustrated the procedure in terms of the safety evaluation of bridges using simple linear elastic 3D Finite Element (FE) model in ABAQUS platform. The design response spectra based on KBC 2009 were then developed, in order to understand the seismic behavior of bridge structures. Besides, the multiple directional earthquakes were applied and it revealed that the most dominated earthquake direction was transverse direction of the bridge. Also, the bridge structure under the compressive stress was more fragile than the tensile stress and the vertical direction of seismic ground motions was not significantly affected to the structural system.Keywords: seismic, bridge, FEM, evaluation, numerical analysis
Procedia PDF Downloads 3668790 Numerical Investigation of Material Behavior During Non-Equal Channel Multi Angular Extrusion
Authors: Mohamed S. El-Asfoury, Ahmed Abdel-Moneim, Mohamed N. A. Nasr
Abstract:
The current study uses finite element modeling to investigate and analyze a modified form of the from the conventional equal channel multi-angular pressing (ECMAP), using non-equal channels, on the workpiece material plastic deformation. The modified process non-equal channel multi-angular extrusion (NECMAE) is modeled using two-dimensional plane strain finite element model built using the commercial software ABAQUS. The workpiece material used is pure aluminum. The model was first validated by comparing its results to analytical solutions for single-pass equal channel angular extrusion (ECAP), as well as previously published data. After that, the model was used to examine the effects of different % of reductions of the area (for the second stage) on material plastic deformation, corner gap, and required the load. Three levels of reduction in the area were modeled; 10%, 30%, and 50%, and compared to single-pass and double-pass ECAP. Cases with a higher reduction in the area were found to have smaller corner gaps, higher and much uniform plastic deformation, as well as higher required loads. The current results are mainly attributed to the back pressure effects exerted by the second stage, as well as strain hardening effects experienced during the first stage.Keywords: non-equal channel angular extrusion, multi-pass, sever plastic deformation, back pressure, Finite Element Modelling (FEM)
Procedia PDF Downloads 4228789 Effect of Mesh Size on the Supersonic Viscous Flow Parameters around an Axisymmetric Blunt Body
Authors: Haoui Rabah
Abstract:
The aim of this work is to analyze a viscous flow around the axisymmetric blunt body taken into account the mesh size both in the free stream and into the boundary layer. The resolution of the Navier-Stokes equations is realized by using the finite volume method to determine the flow parameters and detached shock position. The numerical technique uses the Flux Vector Splitting method of Van Leer. Here, adequate time stepping parameter, CFL coefficient and mesh size level are selected to ensure numerical convergence. The effect of the mesh size is significant on the shear stress and velocity profile. The best solution is obtained with using a very fine grid. This study enabled us to confirm that the determination of boundary layer thickness can be obtained only if the size of the mesh is lower than a certain value limits given by our calculations.Keywords: supersonic flow, viscous flow, finite volume, blunt body
Procedia PDF Downloads 6048788 Biodegradable Poly D,L-Lactide-Co-Glycolic Acid Microparticle Vaccine against Aeromonas hydrophila Infection
Authors: Saekil Yun, Sib Sankar Giri, Jin Woo Jun, Hyoun Joong Kim, Sang Guen Kim, Sang Wha Kim, Jung Woo Kang, Se Jin Han, Se Chang Park
Abstract:
In aquaculture, vaccination is important to control and prevent diseases. In the study, we utilized poly D,L-lactide-co-glycolic acid (PLGA) microparticles (MPs) for encapsulating formalin-killed Aeromonas hydrophila cells. To assess the innate and adaptive immune responses, carps and loaches were used for the experiments. Fish were divided into three groups (A, B, C). Total antigen of 0.1 ml vaccine was adjusted by 2 x 108 CFU and injected via intraperitoneal route. Group A was vaccinated with 0.1 ml of PLGA vaccine, group B was with 0.1 ml of FKC vaccine and group C was with 0.1 ml of sterile PBS. All three groups were challenged with A. hydrophila and challenge dose was lethal dose (LD50). Loaches and carp were then challenged with A. hydrophila at 12 and 20 weeks post vaccination (wpv), and 10 and 14 wpv, respectively, and relative survival rates were calculated. For both fish species, the curve of antibody titer over time was shallower in the PLGA group than the FKC group and the PLGA groups demonstrated higher survival rates at all time-points. In the groups of PLGA-MP, relative mRNA levels of IL-1β, TNF-α, lysozyme C and IgM were significantly upregulated than FKC treated groups. Biodegradable PLGA microparticle vaccine could induce longer immune responses than original FKC vaccines to protect from A. hydrophila infection.Keywords: PLGA, microparticles, Aeromonas hydrophila, vaccine
Procedia PDF Downloads 2728787 Modal FDTD Method for Wave Propagation Modeling Customized for Parallel Computing
Authors: H. Samadiyeh, R. Khajavi
Abstract:
A new FD-based procedure, modal finite difference method (MFDM), is proposed for seismic wave propagation modeling, in which simulation is dealt with in the modal space. The method employs eigenvalues of a characteristic matrix formed by appropriate time-space FD stencils. Since MFD runs for different modes are totally independent of each other, MFDM can easily be parallelized while considerable simplicity in parallel-algorithm is also achieved. There is no requirement to any domain-decomposition procedure and inter-core data exchange. More important is the possibility to skip processing of less-significant modes, which enables one to adjust the procedure up to the level of accuracy needed. Thus, in addition to considerable ease of parallel programming, computation and storage costs are significantly reduced. The method is qualified for its efficiency by some numerical examples.Keywords: Finite Difference Method, Graphics Processing Unit (GPU), Message Passing Interface (MPI), Modal, Wave propagation
Procedia PDF Downloads 2968786 Guided Wave in a Cylinder with Trepezoid Cross-Section
Authors: Nan Tang, Bin Wu, Cunfu He
Abstract:
The trapezoid rods are widely used in civil engineering as load –carrying members. Ultrasonic guided wave is one of the most popular techniques in analyzing the propagation of elastic guided wave. The goal of this paper is to investigate the propagation of elastic waves in the isotropic bar with trapezoid cross-section. Dispersion curves that describe the relationship between the frequency and velocity provide the fundamental information to describe the propagation of elastic waves through a structure. Based on the SAFE (semi-analytical finite element) a linear algebraic system of equations is obtained. By using numerical methods, dispersion curves solved for the rods with the trapezoid cross-section. These fundamental information plays an important role in applying ultrasonic guided waves to NTD for structures with trapezoid cross section.Keywords: guided wave, dispersion, finite element method, trapezoid rod
Procedia PDF Downloads 2928785 Vibration Frequencies Analysis of Nanoporous Graphene Membrane
Authors: Haw-Long Lee, Win-Jin Chang, Yu-Ching Yang
Abstract:
In this study, we use the atomic-scale finite element method to investigate the vibrational behavior of the armchair- and zigzag-structured nanoporous graphene layers with different size under the SFSF and CFFF boundary conditions. The fundamental frequencies computed for the graphene layers without pore are compared with the results of previous studies. We observe very good correspondence of our results with that of the other studies in all the considered cases. For the armchair- and zigzag-structured nanoporous graphene layers under the SFSF and CFFF boundary conditions, the frequencies decrease as the size of the nanopore increase. When the positions of the pore are symmetric with respect to the center of the graphene, the frequency of the zigzag pore graphene is higher than that of the armchair one.Keywords: atomic-scale finite element method, graphene, nanoporous, natural frequency
Procedia PDF Downloads 3618784 Haematological Changes and Anticoccidial Activities of Kaempferol in Eimeria Tenella Infected Broiler Chickens
Authors: Ya'u Muhammad, Umar Umar A. Mallammadori, Dahiru Mansur
Abstract:
Effect of kaempferol on haematological parameters in two weeks old broiler chickens with experimental Eimeria tenella infection was evaluated in this study. Sixty-day old broilers were randomly allotted into six groups (I-VI) of ten broilers each and brooded for two weeks with commercial broiler feed (vital feed®) and provided water ad libitum. At two weeks of age broilers in group 1 were neither infected nor treated. Broilers in groups II-VI were infected with Eimeria tenella sporulated oocyst (104/ml) via oral inoculation. After infection was established, broilers in groups II-IV were treated orally with 1 mg/kg, 1.5 mg/kg, and 2 mg/kg of kaempferol, respectively. Broilers in group V were treated for five days with amprolium, 1.25 g/L in drinking water. Broilers in group VI were administered normal saline, 5 ml/kg per os for five days. Five days post infection; all broilers were sacrificed by severing their jugular veins. Blood sample from each bird was collected in EDTA container for haematology. Caecal contents were harvested and used to determine the lesion score and caecal Oocyst count respectively. Data obtained was analyzed using pad prism version 5.0. Mean Packed Cell Volume (PCV), haemoglobin (Hb) concentration, and Red Blood Cell (RBC) count significantly (P < 0.05) increased in groups II, III, and IV in a dose dependent manner. Similarly, PCV, Hb concentration, and RBC count significantly (P < 0.05) increased in groups II, III, and IV when compared to VI. No significant (P > 0.05) difference in the mean values of PCV, Hb and RBC count were recorded between groups treated with kaempferol and group V. Caecal Oocyst counts and lesion scores reduced significantly (P < 0.05) in groups II, III, and IV in a dose dependent manner. It was therefore observed in this study that kaempferol improved haematological parameters and reduced Oocyst count as well as the lesion scores in broilers infected with Eimeria tenella.Keywords: broilers, Eimeria tenella, kaempferol, lesion scores, oocyst count,
Procedia PDF Downloads 1948783 Numerical and Experimental Analysis of Stiffened Aluminum Panels under Compression
Authors: Ismail Cengiz, Faruk Elaldi
Abstract:
Within the scope of the study presented in this paper, load carrying capacity and buckling behavior of a stiffened aluminum panel designed by adopting current ‘buckle-resistant’ design application and ‘Post –Buckling’ design approach were investigated experimentally and numerically. The test specimen that is stabilized by Z-type stiffeners and manufactured from aluminum 2024 T3 Clad material was test under compression load. Buckling behavior was observed by means of 3 – dimensional digital image correlation (DIC) and strain gauge pairs. The experimental study was followed by developing an efficient and reliable finite element model whose ability to predict behavior of the stiffened panel used for compression test is verified by compering experimental and numerical results in terms of load – shortening curve, strain-load curves and buckling mode shapes. While finite element model was being constructed, non-linear behaviors associated with material and geometry was considered. Finally, applicability of aluminum stiffened panel in airframe design against to composite structures was evaluated thorough the concept of ‘Structural Efficiency’. This study reveals that considerable amount of weight saving could be gained if the concept of ‘post-buckling design’ is preferred to the already conventionally used ‘buckle resistant design’ concept in aircraft industry without scarifying any of structural integrity under load spectrum.Keywords: post-buckling, stiffened panel, non-linear finite element method, aluminum, structural efficiency
Procedia PDF Downloads 1488782 The Effects of Combination of Melatonin with and without Zinc on Gonadotropin Hormones in Female Rats
Authors: Fariba Rahimi, Morteza Zendedel, Mohammad Jaafar Rezaee, Bita Vazir, Shahin Fakour
Abstract:
The present study was carried out to investigate the effect of melatonin (Mel) with and without zinc (Zn) on the gonadotropin hormones, also thyroid (T3 and T4) hormone concentration in female rats. A total of 40 adult female rats were randomly grouped into five treatment groups, each of 2 rats in a Completely Randomized Design (CRD) entire research time. Daily was treated by gavage with Zn and melatonin as follows: T1 (control1, basal diet), T2 (control 2, treated with normal saline) and other experimental groups, including T3, T4 and T5, were treated with a dose of zinc (40 ppm), melatonin (5 mg/kg), and combination zinc plus melatonin with the same level, respectively. Blood FSH and LH concentrations were measured. The result showed no significant differences between treatments in FSH and LH levels. The estrogen and progesterone and TSH levels in rats that received 5 mg of melatonin per day were higher than in other groups but not statistically significant (P>0.05). However, T3 (thyroid) concentration significantly (P<0.05) decreased in the group that received 40 mg/zinc per Kg compared to other groups. No significant (P>0.05) difference was detected among treatments in T4 levels. In conclusion, except for T3, had no significant (P>0.05) effect on another parameter in the female rats that received melatonin or zinc and a blend of melatonin and Zn.Keywords: zinc, melatonin, hormone, rat
Procedia PDF Downloads 1098781 Impact of Relaxing Incisions on Maxillofacial Growth Following Sommerlad–Furlow Modified Technique in Patients with Isolated Cleft Palate: A Preliminary Comparative Study
Authors: Sadam Elayah, Yang Li, Bing Shi
Abstract:
Background: The impact of relaxing incisions on maxillofacial growth during palatoplasty remains a topic of debate, and further research is needed to understand its effects fully. Thus, the current study is the first long-term study that aimed to assess the maxillofacial growth of patients with isolated cleft palate following the Sommerlad-Furlow modified (S.F) technique and to estimate the impact of relaxing incisions on maxillofacial growth following S.F technique in patients with isolated cleft palate. Methods: A total of 85 participants, 55 patients with non-syndromic isolated soft and hard cleft palate underwent primary palatoplasty with our technique (30 patients received the Sommerlad-Furlow modified technique without relaxing incision (S.F+RI group), and 25 received Sommerlad-Furlow modified technique without relaxing (S.F-RI group) with no significant difference found between them regarding the cleft type, cleft width, and age at repair. While the other 30 were normal participants with skeletal class I pattern (C group). The control group was matched with the study group in number, age, and sex. All the study variables were measured using stable landmarks, including 12 linear and 10 angular variants. Results: The mean ages at collection of cephalograms were 6.03±0.80 in the S.F+RI group, 5.96±0.76 in the S.F-RI group, and 5.91±0.87 in the C group. Regarding cranial base, the results showed no statistically significant differences between the three groups in S-N and S-N-Ba. The S.F+R.I group had a significantly shorter S-Ba than the S.F-R.I & C groups (P= 0.01). However, there was no statistically significant difference between the S.F-R.I & C groups (P=0.80). Regarding the skeletal maxilla, there was no significant difference between the S.F+R.I and S.F-R.I groups in all linear measurements (N-ANS, S- PM & SN-PP ) except Co-A, the S.F+R.I group had significantly shorter Co-A than the S.F-R.I & C groups (P= <0.01). While the angular measurement, S.F+R.I group had significantly less SNA angle than the S.F-R.I & C groups (P= <0.01). Regarding mandibular bone, there were no statistically significant differences in all linear and angular mandibular measurements between the S.F+R.I and S.F-R.I groups. Regarding intermaxillary relation, the S.F+R.I group had significant differences in Co-Gn - Co-A and ANB compared to the S.F-R.I & C groups (P= <0.01). There was no statistically significant difference in PP-MP among the three groups. Conclusion: As a preliminary report, the Sommerlad-Furlow modified technique without relaxing incisions was found to have good maxillary positioning in the face and a satisfactory intermaxillary relationship compared to the Sommerlad-Furlow modified technique with relaxing incisions.Keywords: relaxing incisions, cleft palate, palatoplasty, maxillofacial growth
Procedia PDF Downloads 1118780 The Impact of Co-Administration of Phosphodiesterase-5 Inhibitor and Sodium Selenite on Ischemia/Reperfusion Injury in a Rat Ovary Model: Biochemical and Histopathologic Evaluation
Authors: Waleed Aly Sayed Ahmed, Eman Kishk, Tahani Shams
Abstract:
Aim: To study the effects of co-administration of phosphodiesterase-5 inhibitor (PDE-5) and sodium selenite against the damage induced by ovarian ischemia-reperfusion in rats. Materials and Methods: A total of forty-two sexually mature, virgin, female rats were divided randomly into six groups of seven each: sham group (C), ischemia group (I), ischemia/reperfusion group (I/R), ischemia/reperfusion plus 1.4mg/kg sildenafil (I/R+S) group, ischemia/reperfusion plus 0.2mg/kg selenium (I/R+Se) group and ischemia/reperfusion plus combination of sildenafil and selenium (I/R+S+Se) group. In ischemia group (I), rats were exposed to ischemia for 3 hours (h). In ischemia/reperfusion group (I/R), rats were exposed to ischemia for 3 h followed by 6 h of reperfusion. Treated groups received 1.4mg/kg sildenafil or 0.2 mg/kg selenium or both 30 min before reperfusion. Both ovaries were surgically removed carefully. One ovary was examined for histopathological changes and the other was subject to biochemical analysis including malondialdehyde (MDA), catalase (CAT) and glutathione peroxidase (GPx). Results: Assessment of ovarian tissue damage using a scoring system showed marked vascular congestion, interstitial edema, leukocyte infiltration, hemorrhage, and follicular degeneration in ischemia and ischemia/reperfusion groups. Tissue damage score for I, IR and all treated groups were significantly higher than those of the sham group (p<0.001), while tissue damage score decreased significantly in I/R+S and I/R+Se groups compared to I/R group (p<0.05), and notably, the difference was highly significant in I/R+S+Se group (p<0.001). There was significant increase in MDA levels and reduction in activities of CAT and GPx in I/R group compared to the sham group (p < 0.05). In I/R+S and I/R+Se groups, MDA was significantly decreased compared to the I/R group (p<0.05) and the difference was highly significant with co-administration of sildenafil and selenium (p<0.001). CAT and GPx were higher in all treated groups compared to I/R group (p<0.05). Conclusion: The co-administration of sildenafil citrate and selenium are highly protective against damage induced by ovarian ischemia/reperfusion in rats.Keywords: phosphodiesterase-5 inhibitor, sildenafil, antioxidant, selenium, ovarian ischemia
Procedia PDF Downloads 3128779 Gaussian Particle Flow Bernoulli Filter for Single Target Tracking
Authors: Hyeongbok Kim, Lingling Zhao, Xiaohong Su, Junjie Wang
Abstract:
The Bernoulli filter is a precise Bayesian filter for single target tracking based on the random finite set theory. The standard Bernoulli filter often underestimates the number of targets. This study proposes a Gaussian particle flow (GPF) Bernoulli filter employing particle flow to migrate particles from prior to posterior positions to improve the performance of the standard Bernoulli filter. By employing the particle flow filter, the computational speed of the Bernoulli filters is significantly improved. In addition, the GPF Bernoulli filter provides a more accurate estimation compared with that of the standard Bernoulli filter. Simulation results confirm the improved tracking performance and computational speed in two- and three-dimensional scenarios compared with other algorithms.Keywords: Bernoulli filter, particle filter, particle flow filter, random finite sets, target tracking
Procedia PDF Downloads 928778 Development of an Artificial Ear for Bone-Conducted Objective Occlusion Measurement
Authors: Yu Luan
Abstract:
The bone-conducted objective occlusion effect (OE) is characterized by a discomforting sensation of fullness experienced in an occluded ear. This phenomenon arises from various external stimuli, such as human speech, chewing, and walking, which generate vibrations transmitted through the body to the ear canal walls. The bone-conducted OE occurs due to the pressure build-up inside the occluded ear caused by sound radiating into the ear canal cavity from its walls. In the hearing aid industry, artificial ears are utilized as a tool for developing hearing aids. However, the currently available commercial artificial ears primarily focus on pure acoustics measurements, neglecting the bone-conducted vibration aspect. This research endeavors to develop an artificial ear specifically designed for bone-conducted occlusion measurements. Finite element analysis (FEA) modeling has been employed to gain insights into the behavior of the artificial ear.Keywords: artificial ear, bone conducted vibration, occlusion measurement, finite element modeling
Procedia PDF Downloads 878777 Experimental Study on Flexural Strength of Reinforced Geopolymer Concrete Beams
Authors: Khoa Tan Nguyen, Tuan Anh Le, Kihak Lee
Abstract:
This paper presents the flexural response of Reinforced Geopolymer Concrete (RGPC) beams. A commercial finite element (FE) software ABAQUS has been used to perform a structural behavior of RGPC beams. Using parameters such: stress, strain, Young’s modulus, and Poisson’s ratio obtained from experimental results, a beam model has been simulated in ABAQUS. The results from experimental tests and ABAQUS simulation were compared. Due to friction forces at the supports and loading rollers; slip occurring, the actual deflection of RGPC beam from experimental test results were slightly different from the results of ABAQUS. And there is good agreement between the crack patterns of fly ash-based geopolymer concrete generated by FE analysis using ABAQUS, and those in experimental data.Keywords: geopolymer concrete beam, finite element mehod, stress strain relation, modulus elasticity
Procedia PDF Downloads 3928776 An Assessment of Different Blade Tip Timing (BTT) Algorithms Using an Experimentally Validated Finite Element Model Simulator
Authors: Mohamed Mohamed, Philip Bonello, Peter Russhard
Abstract:
Blade Tip Timing (BTT) is a technology concerned with the estimation of both frequency and amplitude of rotating blades. A BTT system comprises two main parts: (a) the arrival time measurement system, and (b) the analysis algorithms. Simulators play an important role in the development of the analysis algorithms since they generate blade tip displacement data from the simulated blade vibration under controlled conditions. This enables an assessment of the performance of the different algorithms with respect to their ability to accurately reproduce the original simulated vibration. Such an assessment is usually not possible with real engine data since there is no practical alternative to BTT for blade vibration measurement. Most simulators used in the literature are based on a simple spring-mass-damper model to determine the vibration. In this work, a more realistic experimentally validated simulator based on the Finite Element (FE) model of a bladed disc (blisk) is first presented. It is then used to generate the necessary data for the assessment of different BTT algorithms. The FE modelling is validated using both a hammer test and two firewire cameras for the mode shapes. A number of autoregressive methods, fitting methods and state-of-the-art inverse methods (i.e. Russhard) are compared. All methods are compared with respect to both synchronous and asynchronous excitations with both single and simultaneous frequencies. The study assesses the applicability of each method for different conditions of vibration, amount of sampling data, and testing facilities, according to its performance and efficiency under these conditions.Keywords: blade tip timing, blisk, finite element, vibration measurement
Procedia PDF Downloads 3108775 Modeling and Simulation of Ship Structures Using Finite Element Method
Authors: Javid Iqbal, Zhu Shifan
Abstract:
The development in the construction of unconventional ships and the implementation of lightweight materials have shown a large impulse towards finite element (FE) method, making it a general tool for ship design. This paper briefly presents the modeling and analysis techniques of ship structures using FE method for complex boundary conditions which are difficult to analyze by existing Ship Classification Societies rules. During operation, all ships experience complex loading conditions. These loads are general categories into thermal loads, linear static, dynamic and non-linear loads. General strength of the ship structure is analyzed using static FE analysis. FE method is also suitable to consider the local loads generated by ballast tanks and cargo in addition to hydrostatic and hydrodynamic loads. Vibration analysis of a ship structure and its components can be performed using FE method which helps in obtaining the dynamic stability of the ship. FE method has developed better techniques for calculation of natural frequencies and different mode shapes of ship structure to avoid resonance both globally and locally. There is a lot of development towards the ideal design in ship industry over the past few years for solving complex engineering problems by employing the data stored in the FE model. This paper provides an overview of ship modeling methodology for FE analysis and its general application. Historical background, the basic concept of FE, advantages, and disadvantages of FE analysis are also reported along with examples related to hull strength and structural components.Keywords: dynamic analysis, finite element methods, ship structure, vibration analysis
Procedia PDF Downloads 1368774 Numerical Analysis of the Response of Thin Flexible Membranes to Free Surface Water Flow
Authors: Mahtab Makaremi Masouleh, Günter Wozniak
Abstract:
This work is part of a major research project concerning the design of a light temporary installable textile flood control structure. The motivation for this work is the great need of applying light structures for the protection of coastal areas from detrimental effects of rapid water runoff. The prime objective of the study is the numerical analysis of the interaction among free surface water flow and slender shaped pliable structures, playing a key role in safety performance of the intended system. First, the behavior of down scale membrane is examined under hydrostatic pressure by the Abaqus explicit solver, which is part of the finite element based commercially available SIMULIA software. Then the procedure to achieve a stable and convergent solution for strongly coupled media including fluids and structures is explained. A partitioned strategy is imposed to make both structures and fluids be discretized and solved with appropriate formulations and solvers. In this regard, finite element method is again selected to analyze the structural domain. Moreover, computational fluid dynamics algorithms are introduced for solutions in flow domains by means of a commercial package of Star CCM+. Likewise, SIMULIA co-simulation engine and an implicit coupling algorithm, which are available communication tools in commercial package of the Star CCM+, enable powerful transmission of data between two applied codes. This approach is discussed for two different cases and compared with available experimental records. In one case, the down scale membrane interacts with open channel flow, where the flow velocity increases with time. The second case illustrates, how the full scale flexible flood barrier behaves when a massive flotsam is accelerated towards it.Keywords: finite element formulation, finite volume algorithm, fluid-structure interaction, light pliable structure, VOF multiphase model
Procedia PDF Downloads 1868773 Dam Break Model Using Navier-Stokes Equation
Authors: Alireza Lohrasbi, Alireza Lavaei, Mohammadali M. Shahlaei
Abstract:
The liquid flow and the free surface shape during the initial stage of dam breaking are investigated. A numerical scheme is developed to predict the wave of an unsteady, incompressible viscous flow with free surface. The method involves a two dimensional finite element (2D), in a vertical plan. The Naiver-Stokes equations for conservation of momentum and mass for Newtonian fluids, continuity equation, and full nonlinear kinematic free-surface equation were used as the governing equations. The mapping developed to solve highly deformed free surface problems common in waves formed during wave propagation, transforms the run up model from the physical domain to a computational domain with Arbitrary Lagrangian Eulerian (ALE) finite element modeling technique.Keywords: dam break, Naiver-Stokes equations, free-surface flows, Arbitrary Lagrangian-Eulerian
Procedia PDF Downloads 3368772 Numerical Study of Laminar Natural Flow Transitions in Rectangular Cavity
Authors: Sabrina Nouri, Abderahmane Ghezal, Said Abboudi, Pierre Spiteri
Abstract:
This paper deals with the numerical study of heat and mass transfer of laminar flow transition at low Prandtl numbers. The model includes the two-directional momentum, the energy and mass transfer equations. These equations are discretized by the finite volume method and solved by a self-made simpler like Fortran code. The effect of governing parameters, namely the Lewis and Prandtl numbers, on the transition of the flow and solute distribution is studied for positive and negative thermal and solutal buoyancy forces ratio. Nusselt and Sherwood numbers are derived for of Prandtl [10⁻²-10¹] and Lewis numbers [1-10⁴]. The results show unicell and multi-cell flow. Solute and flow boundary layers appear for low Prandtl number.Keywords: natural convection, low Prandtl number, heat and mass transfer, finite volume method
Procedia PDF Downloads 1988771 Buckling Analysis of Composite Shells under Compression and Torsional Loads: Numerical and Analytical Study
Authors: Güneş Aydın, Razi Kalantari Osgouei, Murat Emre Öztürk, Ahmad Partovi Meran, Ekrem Tüfekçi
Abstract:
Advanced lightweight laminated composite shells are increasingly being used in all types of modern structures, for enhancing their structural efficiency and performance. Such thin-walled structures are susceptible to buckling when subjected to various loading. This paper focuses on the buckling of cylindrical shells under axial compression and torsional loads. Effects of fiber orientation on the maximum buckling load of carbon fiber reinforced polymer (CFRP) shells are optimized. Optimum fiber angles have been calculated analytically by using MATLAB program. Numerical models have been carried out by using Finite Element Method program ABAQUS. Results from analytical and numerical analyses are also compared.Keywords: buckling, composite, cylindrical shell, finite element, compression, torsion, MATLAB, optimization
Procedia PDF Downloads 5878770 The Effect of Meta-Cognitive Therapy on Meta-Cognitive Defects and Emotional Regulation in Substance Dependence Patients
Authors: Sahra Setorg
Abstract:
The purpose of this study was to determine the effect of meta-cognitive therapy on meta-cognitive defects and emotional regulation in industrial substance dependence patients. This quasi-experimental research was conducted with post-test and two-month follow-up design with control and experimental groups. The statistical population consisted of all industrial Substance dependence patients refer to addictive withdrawal clinics in Esfahan city, in Iran in 2013. 45 patients were selected from three clinics through the convenience sampling method and were randomly divided into two experimental groups (15 crack dependences, 15 amphetamine dependences) and one control group (n=15). The meta-cognitive questionnaire (MCQ) and difficulties in emotional regulation questionnaire (DERS) were used as pre-test measures and the experimental groups (crack and amphetamine) received 8 MC therapy sessions in groups. The data were analyzed via multivariate covariance statistic method by spss-18. The results showed that MCT had a significant effect in improving the meta-cognitive defects in crack and amphetamine dependences. Also, this therapy can increase the emotional regulation in both groups (p<0/05).The effect of this therapy is confirmed in two months followup. According to these findings, met-cognitive is as an interface and important variable in prevention, control, and treatment of the new industrial substance dependences.Keywords: meta-cognitive therapy, meta-cognitive defects, emotional regulation, substance dependence disorder
Procedia PDF Downloads 5138769 The Effect of Choke on the Efficiency of Coaxial Antenna for Percutaneous Microwave Coagulation Therapy for Hepatic Tumor
Authors: Surita Maini
Abstract:
There are many perceived advantages of microwave ablation have driven researchers to develop innovative antennas to effectively treat deep-seated, non-resectable hepatic tumors. In this paper a coaxial antenna with a miniaturized sleeve choke has been discussed for microwave interstitial ablation therapy, in order to reduce backward heating effects irrespective of the insertion depth into the tissue. Two dimensional Finite Element Method (FEM) is used to simulate and measure the results of miniaturized sleeve choke antenna. This paper emphasizes the importance of factors that can affect simulation accuracy, which include mesh resolution, surface heating and reflection coefficient. Quarter wavelength choke effectiveness has been discussed by comparing it with the unchoked antenna with same dimensions.Keywords: microwave ablation, tumor, finite element method, coaxial slot antenna, coaxial dipole antenna
Procedia PDF Downloads 3578768 The Effects of Combination of Melatonin with and Without Zinc on Gonadotropin Hormones in Female Rats
Authors: Fariba Rahimi, Morteza Zendedel, Mohammad Jaafar Rezaee, Bita Vazir, Shahin Fakour
Abstract:
The present study was carried out to investigate the effect of melatonin (Mel) with and without zinc (Zn) on the gonadotropin hormones, also thyroid (T3 and T4) hormone concentration in female rat. A total of 40 adult female rats were randomly grouped into five treatment groups, each of 2 rats in a Completely Randomized Design (CRD) entire research time. Daily were treated by gavaging with Zn and melatonin as following: T1 (control1, basal diet), T2 (control 2, treated with normal saline) and other experimental groups including T3, T4 and T5 were treated with dose of zinc (40 ppm), melatonin (5 mg/kg), and combination zinc plus melatonin with the same level, respectively. Blood FSH and LH concentration were measured. Result showed no significantly differences between treatments in FSH and LH levels. The estrogen and progesterone and TSH levels in rats that received 5 mg of melatonin per day were higher than other groups, but not statistically significant (P>0.05). However, T3 (thyroid) concentration significantly (P<0.05) decreased in group that received 40 mg/zinc per Kg compared other groups. No significant (P>0.05) difference was detected among treatments in T4 levels. In conclusion, except for T3, had not significantly (P>0.05) effect on another parameters in the female rats that received melatonin or zinc and blend of melatonin and Zn.Keywords: zinc, melatonin, hormone, rat
Procedia PDF Downloads 122