Search results for: postoperative radiation therapy
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 3480

Search results for: postoperative radiation therapy

3090 Calculation of Solar Ultraviolet Irradiant Exposure of the Cornea through Sunglasses

Authors: Mauro Masili, Fernanda O. Duarte, Liliane Ventura

Abstract:

Ultraviolet (UV) radiation is electromagnetic waves from 100 – 400 nm wavelength. The World Health Organization and the International Commission on Non-Ionizing Radiation Protection (ICNIRP) recommend guidelines on the exposure of the eyes to UV radiation because it is correlated to ophthalmic diseases. Those exposure limits for an 8-h period are 1) UV radiant exposure should not exceed 30 J/m2 when irradiance is spectrally weighted using an actinic action spectrum; 2) unweighted radiant exposure in the UV-A spectral region 315 – 400 nm should not exceed 10 kJ/m2. Sunglasses play an important role in preventing eye injuries related to Sun exposure. We have calculated the direct and diffuse solar UV irradiance in a geometry that refers to an individual wearing a sunglass, in which the solar rays strike on a vertical surface. The diffuse rays are those scattered from the atmosphere and from the local environment. The calculations used the open-source SMARTS2 spectral model, in which we assumed a clear sky condition, aside from information about site location, date, time, ozone column, aerosols, and turbidity. In addition, we measured the spectral transmittance of a typical sunglasses lens and the global solar irradiance was weighted with the spectral transmittance profile of the lens. The radiant exposure incident on the eye’s surface was calculated in the UV and UV-A ranges following the ICNIRP’s recommendations for each day of the year. The tested lens failed the UV-A safe limit, while the UV limit failed to comply with this limit after the aging process. Hence, the ICNIRP safe limits should be considered in the standards to increase the protection against UV radiation on the eye.

Keywords: ICNIRP safe limits, ISO-12312-1, sunglasses, ultraviolet radiation

Procedia PDF Downloads 90
3089 Evaluation of the Gamma-H2AX Expression as a Biomarker of DNA Damage after X-Ray Radiation in Angiography Patients

Authors: Reza Fardid, Aliyeh Alipour

Abstract:

Introduction: Coronary heart disease (CHD) is the most common and deadliest diseases. A coronary angiography is an important tool for the diagnosis and treatment of this disease. Because angiography is performed by exposure to ionizing radiation, it can lead to harmful effects. Ionizing radiation induces double-stranded breaks in DNA, which is a potentially life-threatening injury. The purpose of the present study is an investigation of the phosphorylation of histone H2AX in the location of the double-stranded break in Peripheral blood lymphocytes as an indication of Biological effects of radiation on angiography patients. Materials and Methods: This method is based on measurement of the phosphorylation of histone (gamma-H2AX, gH2AX) level on serine 139 after formation of DNA double-strand break. 5 cc of blood from 24 patients with angiography were sampled before and after irradiation. Blood lymphocytes were removed, fixed and were stained with specific ϒH2AX antibodies. Finally, ϒH2AX signal as an indicator of the double-strand break was measured with Flow Cytometry Technique. Results and discussion: In all patients, an increase was observed in the number of breaks in double-stranded DNA after irradiation (20.15 ± 14.18) compared to before exposure (1.52 ± 0.34). Also, the mean of DNA double-strand break was showed a linear correlation with DAP. However, although induction of DNA double-strand breaks associated with radiation dose in patients, the effect of individual factors such as radiosensitivity and regenerative capacity should not be ignored. If in future we can measure DNA damage response in every patient angiography and it will be used as a biomarker patient dose, will look very impressive on the public health level. Conclusion: Using flow cytometry readings which are done automatically, it is possible to detect ϒH2AX in the number of blood cells. Therefore, the use of this technique could play a significant role in monitoring patients.

Keywords: coronary angiography, DSB of DNA, ϒH2AX, ionizing radiation

Procedia PDF Downloads 184
3088 Study on the Mechanical Properties of Bamboo Fiber-Reinforced Polypropylene Based Composites: Effect of Gamma Radiation

Authors: Kamrun N. Keya, Nasrin A. Kona, Ruhul A. Khan

Abstract:

Bamboo fiber (BF) reinforced polypropylene (PP) based composites were fabricated by a conventional compression molding technique. In this investigation, bamboo composites were manufactured using different percentages of fiber, which were varying from 25-65% on the total weight of the composites. To fabricate the BF/PP composites untreated and treated fibers were selected. A systematic study was done to observe the physical, mechanical, and interfacial behavior of the composites. In this study, mechanical properties of the composites such as tensile, impact, and bending properties were observed precisely. Maximum tensile strength (TS) and bending strength (BS) were found for 50 wt% fiber composites, 65 MPa, and 85.5 MPa respectively, whereas the highest tensile modulus (TM) and bending modulus (BM) was examined, 5.73 GPa and 7.85 GPa respectively. The BF/PP based composites were treated with irradiated under gamma radiation (the source strength 50 kCi Cobalt-60) of various doses (i.e. 10, 20, 30, 40, 50 and 60 kGy doses). The effect of gamma radiation on the composites was also investigated, and it found that the effect of 30.0 kGy (i.e. units for radiation measurement is 'gray', kGy=kilogray) gamma dose showed better mechanical properties than other doses. After flexural testing, fracture sides of the untreated and treated both composites were studied by scanning electron microscope (SEM). SEM results of the treated BF/PP based composites showed better fiber-matrix adhesion and interfacial bonding than untreated BF/PP based composites. Water uptake and soil degradation tests of untreated and treated composites were also investigated.

Keywords: bamboo fiber, polypropylene, compression molding technique, gamma radiation, mechanical properties, scanning electron microscope

Procedia PDF Downloads 133
3087 Modeling of Strong Motion Generation Areas of the 2011 Tohoku, Japan Earthquake Using Modified Semi-Empirical Technique Incorporating Frequency Dependent Radiation Pattern Model

Authors: Sandeep, A. Joshi, Kamal, Piu Dhibar, Parveen Kumar

Abstract:

In the present work strong ground motion has been simulated using a modified semi-empirical technique (MSET), with frequency dependent radiation pattern model. Joshi et al. (2014) have modified the semi-empirical technique to incorporate the modeling of strong motion generation areas (SMGAs). A frequency dependent radiation pattern model is applied to simulate high frequency ground motion more precisely. Identified SMGAs (Kurahashi and Irikura 2012) of the 2011 Tohoku earthquake (Mw 9.0) were modeled using this modified technique. Records are simulated for both frequency dependent and constant radiation pattern function. Simulated records for both cases are compared with observed records in terms of peak ground acceleration and pseudo acceleration response spectra at different stations. Comparison of simulated and observed records in terms of root mean square error suggests that the method is capable of simulating record which matches in a wide frequency range for this earthquake and bears realistic appearance in terms of shape and strong motion parameters. The results confirm the efficacy and suitability of rupture model defined by five SMGAs for the developed modified technique.

Keywords: strong ground motion, semi-empirical, strong motion generation area, frequency dependent radiation pattern, 2011 Tohoku Earthquake

Procedia PDF Downloads 537
3086 The Effect of Patient Positioning on Pleth Variability Index during Surgery

Authors: Omid Azimaraghi, Noushin Khazaei

Abstract:

Background: Fluid therapy is an important aspect of the perioperative period and a major challenge for anesthesiologists. To authors best knowledge, there is a lack of strong guidance and evidence regarding the optimal approach to fluid therapy. Therefore a variety of medical devices have been introduced to help physicians. In this study, we aimed to evaluate the effectiveness of pleth variability index in guiding fluid therapy in different patient positions. Materials and Methods: Inclusion criteria consisted of patients aged 18-50 years old and classified as American Society of Anesthesiologists physical status I and II, who were candidates for elective thyroidectomy surgery. In total, 36 patients meeting the inclusion criteria were enrolled in the study. After induction of anesthesia and start of mechanical ventilation Pleth variability index was measured in the supine position, then patients were placed in Trendelenburg and reverse Trendelenburg position (30 degrees, 5 minutes); Pleth Variability Index has measured again in the mentioned positions. Results: Mean PVI (Pleth Variability Index) in the supine position was 14.3 ± 3.7 in comparison to 21.5 ± 4.3 in the reverse Trendelenburg position. The mean PVI in Trendelenburg position was 9.1 ± 2.0 in Trendelenburg position (p < 0.05). Conclusion: In conclusion, we found that Pleth Variability Index varies with patient position and this should be taken into account when using this index during fluid therapy.

Keywords: fluid therapy, Pleth Variability Index, position, surgery

Procedia PDF Downloads 166
3085 Development of Typical Meteorological Year for Passive Cooling Applications Using World Weather Data

Authors: Nasser A. Al-Azri

Abstract:

The effectiveness of passive cooling techniques is assessed based on bioclimatic charts that require the typical meteorological year (TMY) for a specified location for their development. However, TMYs are not always available; mainly due to the scarcity of records of solar radiation which is an essential component used in developing common TMYs intended for general uses. Since solar radiation is not required in the development of the bioclimatic chart, this work suggests developing TMYs based solely on the relevant parameters. This approach improves the accuracy of the developed TMY since only the relevant parameters are considered and it also makes the development of the TMY more accessible since solar radiation data are not used. The presented paper will also discuss the development of the TMY from the raw data available at the NOAA-NCDC archive of world weather data and the construction of the bioclimatic charts for some randomly selected locations around the world.

Keywords: bioclimatic charts, passive cooling, TMY, weather data

Procedia PDF Downloads 240
3084 Radiological Hazard Assessments and Control of Radionuclides Emitted from Building Materials in Kuwait Using Expert Systems

Authors: Abdulla Almulla, Wafaa Mahdi

Abstract:

Building materials can make a significant contribution to the level of natural radioactivity in closed dwelling areas. Therefore, developing an expert system for monitoring the activity concentrations (ACs) of naturally occurring radioactive materials (NORMs) existing in building materials is useful for limiting the population’s exposure to gamma radiation emitted from those materials. The present work not only is aimed at examining the indoor radon concentration emitted by the building materials that are originated from various countries but are commercially available in Kuwait, but also is aimed at developing an expert system for monitoring the radiation emitted from these materials and classifying it as normal (acceptable) or dangerous (unacceptable). This system makes it possible to always monitor any radiological risks to human health. When detecting high doses of radiation, the system gives warning messages.

Keywords: building materials, NORMs, HNBRA, radionuclides, activity concentrations, expert systems

Procedia PDF Downloads 169
3083 Effect of Rituximab Therapy Depending on the Age of Disease Onset in Systemic Sclerosis

Authors: Liudmila Garzanova, Lidia Ananyeva, Olga Koneva, Olga Ovsyannikova, Oxana Desinova, Mayya Starovoytova, Rushana Shayahmetova, Anna Khelkovskaya-Sergeeva

Abstract:

Objectives. The age of the disease onset could have an impact on the effect of therapy in systemic sclerosis(SSc). Late-age onset in SSc could have a more severe course of the disease and worse clinical effects on therapy. The aim of our study was to evaluate changes in skin fibrosis on rituximab(RTX) therapy in patients with SSc and different ages of the disease onset. Methods. 151 patients with SSc were included in this study. Patients were divided into groups depending on the age of the disease onset: group 1 - younger than 30 years (40 patients(26%), group 2 - 31-59 years (90 patients(60%) and group 3 – more than 60 years (21 patients(14%). The mean follow-up period was 13±2.3month. The mean age was 48±13years, female-83% of patients, and the diffuse cutaneous subset of the disease had 52% of patients. The mean disease duration was 6.4±5years. The cumulative mean dose of RTX was 1.5±0.6grams. Patients received RTX as a therapy for interstitial lung disease. All patients received prednisone at a dose of 11.6±4.8mg/day, immunosuppressants received 48% of them. The results at baseline and at the end of the follow-up are presented in the form of mean values. Results. There was a significant decrease of modified Rodnan skin score(mRss) in all groups: in group 1 - from 10.2±8 to 7.7±6.5(p=0.01); in group 2 - from 9±7.2 to 6.2±4.7(p=0.0001); in group 3 - from 20.5±14.1 to 10.8±9.4(p=0.001). There was a significant decrease of the activity index (EScSG-AI): in group 1 from 2.5±1.8 to 1.3±1.1; in group 2 – from 3.2±1.6 to 1.5±1.2; in group 3 – from 4.2±2.1 to 1.3±1. Conclusion. There was a significant improvement in skin fibrosis in a year after initiation of RTX therapy regardless of the age of the disease onset. The improvement was more pronounced in the group with late-age onset of the disease, but these data require further investigations.

Keywords: skin fibrosis, systemic sclerosis, rituximab, disease onset

Procedia PDF Downloads 31
3082 Estimation of Hydrogen Production from PWR Spent Fuel Due to Alpha Radiolysis

Authors: Sivakumar Kottapalli, Abdesselam Abdelouas, Christoph Hartnack

Abstract:

Spent nuclear fuel generates a mixed field of ionizing radiation to the water. This radiation field is generally dominated by gamma rays and a limited flux of fast neutrons. The fuel cladding effectively attenuates beta and alpha particle radiation. Small fraction of the spent nuclear fuel exhibits some degree of fuel cladding penetration due to pitting corrosion and mechanical failure. Breaches in the fuel cladding allow the exposure of small volumes of water in the cask to alpha and beta ionizing radiation. The safety of the transport of radioactive material is assured by the package complying with the IAEA Requirements for the Safe Transport of Radioactive Material SSR-6. It is of high interest to avoid generation of hydrogen inside the cavity which may to an explosive mixture. The risk of hydrogen production along with other radiation gases should be analyzed for a typical spent fuel for safety issues. This work aims to perform a realistic study of the production of hydrogen by radiolysis assuming most penalizing initial conditions. It consists in the calculation of the radionuclide inventory of a pellet taking into account the burn up and decays. Westinghouse 17X17 PWR fuel has been chosen and data has been analyzed for different sets of enrichment, burnup, cycles of irradiation and storage conditions. The inventory is calculated as the entry point for the simulation studies of hydrogen production by radiolysis kinetic models by MAKSIMA-CHEMIST. Dose rates decrease strongly within ~45 μm from the fuel surface towards the solution(water) in case of alpha radiation, while the dose rate decrease is lower in case of beta and even slower in case of gamma radiation. Calculations are carried out to obtain spectra as a function of time. Radiation dose rate profiles are taken as the input data for the iterative calculations. Hydrogen yield has been found to be around 0.02 mol/L. Calculations have been performed for a realistic scenario considering a capsule containing the spent fuel rod. Thus, hydrogen yield has been debated. Experiments are under progress to validate the hydrogen production rate using cyclotron at > 5MeV (at ARRONAX, Nantes).

Keywords: radiolysis, spent fuel, hydrogen, cyclotron

Procedia PDF Downloads 521
3081 A Design of Beam-Steerable Antenna Array for Use in Future Mobile Handsets

Authors: Naser Ojaroudi Parchin, Atta Ullah, Haleh Jahanbakhsh Basherlou, Raed A. Abd-Alhameed, Peter S. Excell

Abstract:

A design of beam-steerable antenna array for the future cellular communication (5G) is presented. The proposed design contains eight elements of compact end-fire antennas arranged on the top edge of smartphone printed circuit board (PCB). Configuration of the antenna element consists of the conductive patterns on the top and bottom copper foil layers and a substrate layer with a via-hole. The simulated results including input-impedance and also fundamental radiation properties have been presented and discussed. The impedance bandwidth (S11 ≤ -10 dB) of the antenna spans from 17.5 to 21 GHz (more than 3 GHz bandwidth) with a resonance at 19 GHz. The antenna exhibits end-fire (directional) radiation beams with wide-angle scanning property and could be used for the future 5G beam-forming. Furthermore, the characteristics of the array design in the vicinity of user-hand are studied.

Keywords: beam-steering, end-fire radiation mode, mobile-phone antenna, phased array

Procedia PDF Downloads 154
3080 A Brief Narrative Intervention to Improve Well-being and Relational Ethics in Couples: A Mixed-Method Case Study

Authors: Kevser Cakmak, Adrián Montesano, Lourdes Artigas, Marta Salla, Clara Mateu

Abstract:

The main objective of this research is to explore the relational letter writing technique as an intervention in couple therapy for reconnecting couples with their values and ethical preferences. This is a recently developed therapeutic tool within the framework of Narrative Therapy that consists of two interviews and a letter writing task, in which a meta-conversation between the relationship itself, the couple members, and the therapists is fostered. Although this specific therapeutic technique can be used within the therapy process, in this case study, it is used as a brief stand-alone narrative intervention for a middle age heterosexual couple breast cancer survivor. Couple’s relational and personal wellbeing was monitored before, during, and after the intervention by means of the dyadic adjustment and the clinical outcomes in routine evaluation-outcome measure, respectively. The couple showed a significant improvement after the intervention in both levels. The content of the letter writing exercises was qualitatively analysed to explore the reconstruction of their ethical values. Results from both methods are integrated in order to get an in-depth perspective of the newly developed tool. The potential of the letter writing technique as stand-alone and as adjunct brief intervention is discussed.

Keywords: couple therapy, narrative therapy, psychotherapy tool, relational letter writing

Procedia PDF Downloads 134
3079 The Use of Coronary Calcium Scanning for Cholesterol Assessment and Management

Authors: Eva Kirzner

Abstract:

Based on outcome studies published over the past two decades, in 2018, the ACC/AHA published new guidelines for the management of hypercholesterolemia that incorporate the use of coronary artery calcium (CAC) scanning as a decision tool for ascertaining which patients may benefit from statin therapy. This use is based on the recognition that the absence of calcium on CAC scanning (i.e., a CAC score of zero) usually signifies the absence of significant atherosclerotic deposits in the coronary arteries. Specifically, in patients with a high risk for atherosclerotic cardiovascular disease (ASCVD), initiation of statin therapy is generally recommended to decrease ASCVD risk. However, among patients with intermediate ASCVD risk, the need for statin therapy is less certain. However, there is a need for new outcome studies that provide evidence that the management of hypercholesterolemia based on these new ACC/AHA recommendations is safe for patients. Based on a Pub-Med and Google Scholar literature search, four relevant population-based or patient-based cohort studies that studied the relationship between CAC scanning, risk assessment or mortality, and statin therapy that were published between 2017 and 2021 were identified (see references). In each of these studies, patients were assessed for their baseline risk for atherosclerotic cardiovascular disease (ASCVD) using the Pooled Cohorts Equation (PCE), an ACC/AHA calculator for determining patient risk based on assessment of patient age, gender, ethnicity, and coronary artery disease risk factors. The combined findings of these four studies provided concordant evidence that a zero CAC score defines patients who remain at low clinical risk despite the non-use of statin therapy. Thus, these new studies confirm the use of CAC scanning as a safe tool for reducing the potential overuse of statin therapy among patients with zero CAC scores. Incorporating these new data suggest the following best practice: (1) ascertain ASCVD risk according to the PCE in all patients; (2) following an initial attempt trial to lower ASCVD risk with optimal diet among patients with elevated ASCVD risk, initiate statin therapy for patients who have a high ASCVD risk score; (3) if the ASCVD score is intermediate, refer patients for CAC scanning; and (4) and if the CAC score is zero among the intermediate risk ASCVD patients, statin therapy can be safely withheld despite the presence of an elevated serum cholesterol level.

Keywords: cholesterol, cardiovascular disease, statin therapy, coronary calcium

Procedia PDF Downloads 115
3078 Predictors of Pericardial Effusion Requiring Drainage Following Coronary Artery Bypass Graft Surgery: A Retrospective Analysis

Authors: Nicholas McNamara, John Brookes, Michael Williams, Manish Mathew, Elizabeth Brookes, Tristan Yan, Paul Bannon

Abstract:

Objective: Pericardial effusions are an uncommon but potentially fatal complication after cardiac surgery. The goal of this study was to describe the incidence and risk factors associated with the development of pericardial effusion requiring drainage after coronary artery bypass graft surgery (CABG). Methods: A retrospective analysis was undertaken using prospectively collected data. All adult patients who underwent CABG at our institution between 1st January 2017 and 31st December 2018 were included. Pericardial effusion was diagnosed using transthoracic echocardiography (TTE) performed for clinical suspicion of pre-tamponade or tamponade. Drainage was undertaken if considered clinically necessary and performed via a sub-xiphoid incision, pericardiocentesis, or via re-sternotomy at the discretion of the treating surgeon. Patient demographics, operative characteristics, anticoagulant exposure, and postoperative outcomes were examined to identify those variables associated with the development of pericardial effusion requiring drainage. Tests of association were performed using the Fischer exact test for dichotomous variables and the Student t-test for continuous variables. Logistic regression models were used to determine univariate predictors of pericardial effusion requiring drainage. Results: Between January 1st, 2017, and December 31st, 2018, a total of 408 patients underwent CABG at our institution, and eight (1.9%) required drainage of pericardial effusion. There was no difference in age, gender, or the proportion of patients on preoperative therapeutic heparin between the study and control groups. Univariate analysis identified preoperative atrial arrhythmia (37.5% vs 8.8%, p = 0.03), reduced left ventricular ejection fraction (47% vs 56%, p = 0.04), longer cardiopulmonary bypass (130 vs 84 min, p < 0.01) and cross-clamp (107 vs 62 min, p < 0.01) times, higher drain output in the first four postoperative hours (420 vs 213 mL, p <0.01), postoperative atrial fibrillation (100% vs 32%, p < 0.01), and pleural effusion requiring drainage (87.5% vs 12.5%, p < 0.01) to be associated with development of pericardial effusion requiring drainage. Conclusion: In this study, the incidence of pericardial effusion requiring drainage was 1.9%. Several factors, mainly related to preoperative or postoperative arrhythmia, length of surgery, and pleural effusion requiring drainage, were identified to be associated with developing clinically significant pericardial effusions. High clinical suspicion and low threshold for transthoracic echo are pertinent to ensure this potentially lethal condition is not missed.

Keywords: coronary artery bypass, pericardial effusion, pericardiocentesis, tamponade, sub-xiphoid drainage

Procedia PDF Downloads 161
3077 The Effects of Therapy on Oxidative Stress, Ghrelin and Nesfatin-1 Levels in Iron Deficiency Anemia

Authors: Emrah Caylak

Abstract:

The aim of this study is to investigate the effect of iron therapy on oxidative stress, ghrelin, and nesfatin-1 levels in patients with iron deficiency anemia (IDA). Thirty patients who applied to Internal Medicine Clinic and were diagnosed with IDA and also 30 healthy individuals as a control were included in the study. The samples were collected from IDA patients before and after treatment. Differences in serum MDA, TAC, and plasma ghrelin, nesfatin-1 were analyzed among the three groups. Serum MDA and TAC levels were found higher and lower in IDA patients before the treatment group compared to the controls (p < 0.05). After the iron therapy, plasma acylated ghrelin and nesfatin-1 levels in IDA patients were found higher in IDA patients before the treatment group and controls (p < 0.05). Plasma ghrelin and nesfatin-1 levels increase with iron treatment in IDA patients. The iron therapy induces the synthesis of ghrelin and nesfatin-1 in human body, thus causes increased appetite and food intake.

Keywords: anemia, oxidative stress, ghrelin, nesfatin-1

Procedia PDF Downloads 144
3076 Effect of Low Level Laser for Athletic Achilles Tendinopathy: A Systematic Review

Authors: Sameh Eldaly, Rola Essam

Abstract:

Objective: The purpose of this study was to determine the benefits of low-level laser therapy for Athletic Achilles Tendinopathy. Data sources: Search strategies were conducted on 2 Randomized control trial and one pilot study. Results: three trials (103 participants) were analyzed. Laser therapy associated to eccentric exercises, when compared to eccentric exercises and placebo, had low to very low certainty of evidence in pain and function assessment. Conclusion: those three trials evidenced low to very low effect of LLLT, and the results are insufficient to support the routine use LLLT for Achilles tendinopathy.

Keywords: achilles tendinopathy, evidence-based, low-level laser therapy, review

Procedia PDF Downloads 81
3075 The Use of Music Therapy to Improve Non-Verbal Communication Skills for Children with Autism

Authors: Maria Vinca Novenia

Abstract:

The number of school-aged children with autism in Indonesia has been increasing each year. Autism is a developmental disorder which can be diagnosed in childhood. One of the symptoms is the lack of communication skills. Music therapy is known as an effective treatment for children with autism. Music elements and structures create a good space for children with autism to express their feelings and communicate their thoughts. School-aged children are expected to be able to communicate non-verbally very well, but children with autism experience the difficulties of communicating non-verbally. The aim of this research is to analyze the significance of music therapy treatment to improve non-verbal communication tools for children with autism. This research informs teachers and parents on how music can be used as a media to communicate with children with autism. The qualitative method is used to analyze this research, while the result is described with the microanalysis technique. The result is measured specifically from the whole experiment, hours of every week, minutes of every session, and second of every moment. The samples taken are four school-aged children with autism in the age range of six to 11 years old. This research is conducted within four months started with observation, interview, literature research, and direct experiment. The result demonstrates that music therapy could be effectively used as a non-verbal communication tool for children with autism, such as changes of body gesture, eye contact, and facial expression.

Keywords: autism, improvisation, microanalysis, music therapy, nonverbal communication, school-aged

Procedia PDF Downloads 222
3074 Simulations to Predict Solar Energy Potential by ERA5 Application at North Africa

Authors: U. Ali Rahoma, Nabil Esawy, Fawzia Ibrahim Moursy, A. H. Hassan, Samy A. Khalil, Ashraf S. Khamees

Abstract:

The design of any solar energy conversion system requires the knowledge of solar radiation data obtained over a long period. Satellite data has been widely used to estimate solar energy where no ground observation of solar radiation is available, yet there are limitations on the temporal coverage of satellite data. Reanalysis is a “retrospective analysis” of the atmosphere parameters generated by assimilating observation data from various sources, including ground observation, satellites, ships, and aircraft observation with the output of NWP (Numerical Weather Prediction) models, to develop an exhaustive record of weather and climate parameters. The evaluation of the performance of reanalysis datasets (ERA-5) for North Africa against high-quality surface measured data was performed using statistical analysis. The estimation of global solar radiation (GSR) distribution over six different selected locations in North Africa during ten years from the period time 2011 to 2020. The root means square error (RMSE), mean bias error (MBE) and mean absolute error (MAE) of reanalysis data of solar radiation range from 0.079 to 0.222, 0.0145 to 0.198, and 0.055 to 0.178, respectively. The seasonal statistical analysis was performed to study seasonal variation of performance of datasets, which reveals the significant variation of errors in different seasons—the performance of the dataset changes by changing the temporal resolution of the data used for comparison. The monthly mean values of data show better performance, but the accuracy of data is compromised. The solar radiation data of ERA-5 is used for preliminary solar resource assessment and power estimation. The correlation coefficient (R2) varies from 0.93 to 99% for the different selected sites in North Africa in the present research. The goal of this research is to give a good representation for global solar radiation to help in solar energy application in all fields, and this can be done by using gridded data from European Centre for Medium-Range Weather Forecasts ECMWF and producing a new model to give a good result.

Keywords: solar energy, solar radiation, ERA-5, potential energy

Procedia PDF Downloads 211
3073 Xenografts: Successful Penetrating Keratoplasty Between Two Species

Authors: Francisco Alvarado, Luz Ramírez

Abstract:

Corneal diseases are one of the main causes of visual impairment and affect almost 4 million, and this study assesses the effects of deep anterior lamellar keratoplasty (DALK) with porcine corneal stroma and postoperative topical treatment with tacrolimus in patients with infectious keratitis. No patient was observed with clinical graft rejection. Among the cases: 2 were positive to fungal culture, 2 with Aspergillus and the other 8 cases were confirmed by bacteriological culture. Corneal diseases are one of the main causes of visual impairment and affect almost 4 million. This study assesses the effects of deep anterior lamellar keratoplasty (DALK) with porcine corneal stroma and postoperative topical treatment with tacrolimus in patients with infectious keratitis. Receiver bed diameters ranged from 7.00 to 9.00 mm. No incidents of Descemet's membrane perforation were observed during surgery. During the follow-up period, no corneal graft splitting, IOP increase, or intolerance to tacrolimus were observed. Deep anterior lamellar keratoplasty seems to be the best option to avoid xenograft rejection, and it could help new surgical techniques in humans.

Keywords: ophthalmology, cornea, corneal transplant, xenografts, surgical innovations

Procedia PDF Downloads 83
3072 Thermal Radiation Effect on Mixed Convection Boundary Layer Flow over a Vertical Plate with Varying Density and Volumetric Expansion Coefficient

Authors: Sadia Siddiqa, Z. Khan, M. A. Hossain

Abstract:

In this article, the effect of thermal radiation on mixed convection boundary layer flow of a viscous fluid along a highly heated vertical flat plate is considered with varying density and volumetric expansion coefficient. The density of the fluid is assumed to vary exponentially with temperature, however; volumetric expansion coefficient depends linearly on temperature. Boundary layer equations are transformed into convenient form by introducing primitive variable formulations. Solutions of transformed system of equations are obtained numerically through implicit finite difference method along with Gaussian elimination technique. Results are discussed in view of various parameters, like thermal radiation parameter, volumetric expansion parameter and density variation parameter on the wall shear stress and heat transfer rate. It is concluded from the present investigation that increase in volumetric expansion parameter decreases wall shear stress and enhances heat transfer rate.

Keywords: thermal radiation, mixed convection, variable density, variable volumetric expansion coefficient

Procedia PDF Downloads 368
3071 Design and Simulation of a Radiation Spectrometer Using Scintillation Detectors

Authors: Waleed K. Saib, Abdulsalam M. Alhawsawi, Essam Banoqitah

Abstract:

The idea of this research is to design a radiation spectrometer using LSO scintillation detector coupled to a C series of SiPM (silicon photomultiplier). The device can be used to detects gamma and X-ray radiation. This device is also designed to estimates the activity of the source contamination. The SiPM will detect light in the visible range above the threshold and read them as counts. Three gamma sources were used for these experiments Cs-137, Am-241 and Co-60 with various activities. These sources are applied for four experiments operating the SiPM as a spectrometer, energy resolution, pile-up set and efficiency. The SiPM is connected to a MCA to perform as a spectrometer. Cerium doped Lutetium Silicate (Lu₂SiO₅) with light yield 26000 photons/Mev coupled with the SiPM. As a result, all the main features of the Cs-137, Am-241 and Co-60 are identified in MCA. The experiment shows how photon energy and probability of interaction are inversely related. Total attenuation reduces as photon energy increases. An analytical calculation was made to obtain the FWHM resolution for each gamma source. The FWHM resolution for Am-241 (59 keV) is 28.75 %, for Cs-137 (662 keV) is 7.85 %, for Co-60 (1173 keV) is 4.46 % and for Co-60 (1332 keV) is 3.70%. Moreover, the experiment shows that the dead time and counts number decreased when the pile-up rejection was disabled and the FWHM decreased when the pile-up was enabled. The efficiencies were calculated at four different distances from the detector 2, 4, 8 and 16 cm. The detection efficiency was observed to declined exponentially with increasing distance from the detector face. Conclusively, the SiPM board operated with an LSO scintillator crystal as a spectrometer. The SiPM energy resolution for the three gamma sources used was a decent comparison to other PMTs.

Keywords: PMT, radiation, radiation detection, scintillation detectors, silicon photomultiplier, spectrometer

Procedia PDF Downloads 154
3070 Fabrication and Mechanical Characterization of Sugarcane Bagasse Fiber-Reinforced Polypropylene Based Composites: Effect of Gamma Radiation

Authors: Kamrun N. Keya, Nasrin A. Kona, Ruhul A. Khan

Abstract:

Sugarcane bagasse (SCB)-reinforced Polypropylene (PP) Based matrix composites (25-45 wt% fiber) were fabricated by a compression molding technique. The SCB surface was chemically modified using 5%-10% sodium hydroxide (NaOH), and after that, mechanical properties, water uptake, and soil degradation of the composites were investigated. Tensile strength (TS), tensile modulus (TM), bending strength (BS), bending modulus (BM) and elongation at break (Eb%) of the 30wt% composites were found to be 35.6 MPa, 10.2 GPa, 56 MPa, 5.6 GPa, and 11%, respectively. The SCB/PP based composites were treated with irradiated under gamma radiation (the source strength 50 kCi Cobalt-60) of various doses (2.5 kGy to 10 kGy). The effect of gamma radiation on the composites was also investigated, and it found that the effect of 5.0 kGy (i.e. units for radiation measurement is 'gray', kGy=kilogray ) gamma dose showed better mechanical properties than other doses. The results revealed that the combination of the chemical modification of the SCB fibers and irradiation of the composites were more effective in compatibility improvement than chemical modification alone. After flexural testing, fracture sides of the untreated and treated both composites were studied by scanning electron microscope (SEM). SEM results of the treated SCB/PP based composites showed better fiber-matrix adhesion than untreated SCB/PP based composites. However, it was found that the treated SCB/PP composite has better mechanical strength, durability, and more receptivity than untreated SCB/PP based composite.

Keywords: sugarcane bagasse (SCB), polypropylene (PP), mechanical properties, scanning electron microscope (SEM), gamma radiation, water uptake tests and soil degradation

Procedia PDF Downloads 137
3069 Design of a Portable Shielding System for a Newly Installed NaI(Tl) Detector

Authors: Mayesha Tahsin, A.S. Mollah

Abstract:

Recently, a 1.5x1.5 inch NaI(Tl) detector based gamma-ray spectroscopy system has been installed in the laboratory of the Nuclear Science and Engineering Department of the Military Institute of Science and Technology for radioactivity detection purposes. The newly installed NaI(Tl) detector has a circular lead shield of 22 mm width. An important consideration of any gamma-ray spectroscopy is the minimization of natural background radiation not originating from the radioactive sample that is being measured. Natural background gamma-ray radiation comes from naturally occurring or man-made radionuclides in the environment or from cosmic sources. Moreover, the main problem with this system is that it is not suitable for measurements of radioactivity with a large sample container like Petridish or Marinelli beaker geometry. When any laboratory installs a new detector or/and new shield, it “must” first carry out quality and performance tests for the detector and shield. This paper describes a new portable shielding system with lead that can reduce the background radiation. Intensity of gamma radiation after passing the shielding will be calculated using shielding equation I=Ioe-µx where Io is initial intensity of the gamma source, I is intensity after passing through the shield, µ is linear attenuation coefficient of the shielding material, and x is the thickness of the shielding material. The height and width of the shielding will be selected in order to accommodate the large sample container. The detector will be surrounded by a 4π-geometry low activity lead shield. An additional 1.5 mm thick shield of tin and 1 mm thick shield of copper covering the inner part of the lead shielding will be added in order to remove the presence of characteristic X-rays from the lead shield.

Keywords: shield, NaI (Tl) detector, gamma radiation, intensity, linear attenuation coefficient

Procedia PDF Downloads 158
3068 Modeling of Global Solar Radiation on a Horizontal Surface Using Artificial Neural Network: A Case Study

Authors: Laidi Maamar, Hanini Salah

Abstract:

The present work investigates the potential of artificial neural network (ANN) model to predict the horizontal global solar radiation (HGSR). The ANN is developed and optimized using three years meteorological database from 2011 to 2013 available at the meteorological station of Blida (Blida 1 university, Algeria, Latitude 36.5°, Longitude 2.81° and 163 m above mean sea level). Optimal configuration of the ANN model has been determined by minimizing the Root Means Square Error (RMSE) and maximizing the correlation coefficient (R2) between observed and predicted data with the ANN model. To select the best ANN architecture, we have conducted several tests by using different combinations of parameters. A two-layer ANN model with six hidden neurons has been found as an optimal topology with (RMSE=4.036 W/m²) and (R²=0.999). A graphical user interface (GUI), was designed based on the best network structure and training algorithm, to enhance the users’ friendliness application of the model.

Keywords: artificial neural network, global solar radiation, solar energy, prediction, Algeria

Procedia PDF Downloads 498
3067 Stress Hyperglycaemia and Glycaemic Control Post Cardiac Surgery: Relaxed Targets May Be Acceptable

Authors: Nicholas Bayfield, Liam Bibo, Charley Budgeon, Robert Larbalestier, Tom Briffa

Abstract:

Introduction: Stress hyperglycaemia is common following cardiac surgery. Its optimal management is uncertain and may differ by diabetic status. This study assesses the in-hospital glycaemic management of cardiac surgery patients and associated postoperative outcomes. Methods: A retrospective cohort analysis of all patients undergoing cardiac surgery at Fiona Stanley Hospital from February 2015 to May 2019 was undertaken. Management and outcomes of hyperglycaemia following cardiac surgery were assessed. Follow-up was assessed to 1 year postoperatively. Multivariate regression modelling was utilised. Results: 1050 non-diabetic patients and 689 diabetic patients were included. In the non-diabetic cohort, patients with mild (peak blood sugar level [BSL] < 14.3), transient stress hyperglycaemia managed without insulin were not at an increased risk of wound-related morbidity (P=0.899) or mortality at 1 year (P=0.483). Insulin management was associated with wound-related readmission to hospital (P=0.004) and superficial sternal wound infection (P=0.047). Prolonged or severe stress hyperglycaemia was predictive of hospital re-admission (P=0.050) but not morbidity or mortality (P=0.546). Diabetes mellitus was an independent risk factor 1-year mortality (OR; 1.972 [1.041–3.736], P=0.037), graft harvest site wound infection (OR; 1.810 [1.134–2.889], P=0.013) and wound-related readmission (OR; 1.866 [1.076–3.236], P=0.026). In diabetics, postoperative peak BSL > 13.9mmol/L was predictive of graft harvest site infections (OR; 3.528 [1.724-7.217], P=0.001) and wound-related readmission OR; 3.462 [1.540-7.783], P=0.003) regardless of modality of management. A peak BSL of 10.0-13.9 did not increase the risk of morbidity/mortality compared to a peak BSL of < 10.0 (P=0.557). Diabetics with a peak BSL of 13.9 or less did not have significantly increased morbidity/mortality outcomes compared to non-diabetics (P=0.418). Conclusion: In non-diabetic patients, transient mild stress hyperglycaemia following cardiac surgery does not uniformly require treatment. In diabetic patients, postoperative hyperglycaemia with peak BSL exceeding 13.9mmol/L was associated with wound-related morbidity and hospital readmission following cardiac surgery.

Keywords: cardiac surgery, pulmonary embolism, pulmonary embolectomy, cardiopulmonary bypass

Procedia PDF Downloads 162
3066 Benefits of Therapeutic Climbing on Multiple Components of Attention in Attention Deficit Hyperactivity Disorder Children

Authors: Elaheh Hosseini, Otmar Bock, Monika Thomas

Abstract:

The purpose of the present study was to determine the effect of climbing therapy on the components of attention of children with attention-deficit hyperactivity disorder (ADHD). Forty children with ADHD were assigned to either an intervention group or a control group. The exercise group participated in a climbing therapy program for ten weeks, whereas no intervention was administered to the control group. All two groups were then assessed with the same battery of attention tests used in our earlier study. We found that compared to the ‘intervention’ group, performance was higher in the ‘control’ group on tests of sustained, divided and distributed attention, on all four tests. The intervention group showed a significant improvement in components of attention after ten weeks. From this we conclude that climbing therapy can improve the attention of children with ADHD and can be considered as a promising intervention and a standalone treatment for children with ADHD.

Keywords: ADHD, climbing therapy, distributed attention, divided attention, selective attention, sustained attention

Procedia PDF Downloads 162
3065 Analysis of Combined Heat Transfer through the Core Materials of VIPs with Various Scattering Properties

Authors: Jaehyug Lee, Tae-Ho Song

Abstract:

Vacuum insulation panel (VIP) can achieve very low thermal conductivity by evacuating its inner space. Heat transfer in the core materials of highly-evacuated VIP occurs by conduction through the solid structure and radiation through the pore. The effect of various scattering modes in combined conduction-radiation in VIP is investigated through numerical analysis. The discrete ordinates interpolation method (DOIM) incorporated with the commercial code FLUENT® is employed. It is found that backward scattering is more effective in reducing the total heat transfer while isotropic scattering is almost identical with pure absorbing/emitting case of the same optical thickness. For a purely scattering medium, the results agree well with additive solution with diffusion approximation, while a modified term is added in the effect of optical thickness to backward scattering is employed. For other scattering phase functions, it is also confirmed that backwardly scattering phase function gives a lower effective thermal conductivity. Thus, the materials with backward scattering properties, with radiation shields are desirable to lower the thermal conductivity of VIPs.

Keywords: combined conduction and radiation, discrete ordinates interpolation method, scattering phase function, vacuum insulation panel

Procedia PDF Downloads 366
3064 Gait Analysis in Total Knee Arthroplasty

Authors: Neeraj Vij, Christian Leber, Kenneth Schmidt

Abstract:

Introduction: Total knee arthroplasty is a common procedure. It is well known that the biomechanics of the knee do not fully return to their normal state. Motion analysis has been used to study the biomechanics of the knee after total knee arthroplasty. The purpose of this scoping review is to summarize the current use of gait analysis in total knee arthroplasty and to identify the preoperative motion analysis parameters for which a systematic review aimed at determining the reliability and validity may be warranted. Materials and Methods: This IRB-exempt scoping review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) checklist strictly. Five search engines were searched for a total of 279 articles. Articles underwent a title and abstract screening process followed by full-text screening. Included articles were placed in the following sections: the role of gait analysis as a research tool for operative decisions, other research applications for motion analysis in total knee arthroplasty, gait analysis as a tool in predicting radiologic outcomes, gait analysis as a tool in predicting clinical outcomes. Results: Eleven articles studied gait analysis as a research tool in studying operative decisions. Motion analysis is currently used to study surgical approaches, surgical techniques, and implant choice. Five articles studied other research applications for motion analysis in total knee arthroplasty. Other research applications for motion analysis currently include studying the role of the unicompartmental knee arthroplasty and novel physical therapy protocols aimed at optimizing post-operative care. Two articles studied motion analysis as a tool for predicting radiographic outcomes. Preoperative gait analysis has identified parameters than can predict postoperative tibial component migration. 15 articles studied motion analysis in conjunction with clinical scores. Conclusions: There is a broad range of applications within the research domain of total knee arthroplasty. The potential application is likely larger. However, the current literature is limited by vague definitions of ‘gait analysis’ or ‘motion analysis’ and a limited number of articles with preoperative and postoperative functional and clinical measures. Knee adduction moment, knee adduction impulse, total knee range of motion, varus angle, cadence, stride length, and velocity have the potential for integration into composite clinical scores. A systematic review aimed at determining the validity, reliability, sensitivities, and specificities of these variables is warranted.

Keywords: motion analysis, joint replacement, patient-reported outcomes, knee surgery

Procedia PDF Downloads 93
3063 The Effectiveness of Solution-Focused Group Therapy on Improving Depressed Mothers of Child Abuser Families

Authors: Roya Maqami, Kaveh Qaderi Bagajan, Mohammad Mahdi Yousefi, Saeed Moradi

Abstract:

The purpose of this study is to investigate the efficacy of solution-focused group therapy on improving the depressed mothers of child abuser families. This study was carried out in the form of a semi-pilot, pre-test and post-test on two groups (experimental and control). Subjects include all mothers and their children that are the members of Shush and Naser Khosro child home. Beck Depression Inventory and Child Trauma Questionnaire were used to collect data. First, child abuse questionnaire was completed by children, Then Beck Depression Inventory was completed by their mothers that 22 of them were recognized as depressed and randomly divided in two groups of experimental and control. After applying pre-test for both of these groups, the intervention of solution- focused group therapy was performed in five sessions on experimental group. Finally, post-test was applied on both groups and subsequently in a month, follow-up test was performed. T-test, multivariate variance, and repeated measurement analysis of variance were used to analyze the data. According to the findings, it can be concluded that this therapy leads to the improvement of depressed mother's mood. As a result, the intervention of solution-focused group therapy is useful in order to improve the depressing mood of mothers of child abuser families.

Keywords: child abuse, depressed mothers, child abuser families, solution focused group therapy

Procedia PDF Downloads 359
3062 Investigating Nanocrystalline CaF2:Tm for Carbon Beam and Gamma Radiation Dosimetry

Authors: Kanika Sharma, Shaila Bahl, Birendra Singh, Pratik Kumar, S. P. Lochab, A. Pandey

Abstract:

In the present investigation, initially nano-particles of CaF2 were prepared by the chemical co-precipitation method and later the prepared salt was activated by thulium (0.1 mol%) using the combustion technique. The final product was characterized and confirmed by X-Ray diffraction (XRD) and transmission electron microscopy (TEM). Further, the thermoluminescence (TL) properties of the nanophosphor were studied by irradiating it with 1.25 MeV of gamma radiation and 65 MeV of carbon (C6+) ion beam. For gamma rays, two prominent TL peaks were observed with a low temperature peak at around 1070C and a high temperature peak at around 1570C. Furthermore, the nanophosphor maintained a linear TL response for the entire range of studied doses i.e. 10 Gy to 2000 Gy for both the temperature peaks. Moreover, when the nanophosphor was irradiated with 65 MeV of C6+ ion beam the shape and structure of the glow curves remained spectacularly similar and the nanophosphor displayed a linear TL response for the full range of studied fluences i.e. 5*1010 ions/cm2 to 1 *1012 ions/ cm2. Finally, various tests like reproducibility test and batch homogeneity were also carried out to define the final product. Thus, co-precipitation method followed by combustion technique was successful in effectively producing dosimetric grade CaF2:Tm for dosimetry of gamma as well as carbon (C6+) beam.

Keywords: gamma radiation, ion beam, nanocrystalline, radiation dosimetry

Procedia PDF Downloads 184
3061 The MCNP Simulation of Prompt Gamma-Ray Neutron Activation Analysis at TRR-1/M1

Authors: S. Sangaroon, W. Ratanatongchai, S. Khaweerat, R. Picha, J. Channuie

Abstract:

The prompt gamma-ray neutron activation analysis system (PGNAA) has been constructed and installed at a 6 inch diameter neutron beam port of the Thai Research Reactor-1/ Modification 1 (TRR-1/M1) since 1989. It was designed for the reactor operating power at 1.2 MW. The purpose of the system is for an elemental and isotopic analytical. In 2016, the PGNAA facility will be developed to reduce the leakage and background of neutrons and gamma radiation at the sample and detector position. In this work, the designed condition of these facilities is carried out based on the Monte Carlo method using MCNP5 computer code. The conditions with different modification materials, thicknesses and structure of the PGNAA facility, including gamma collimator and radiation shields of the detector, are simulated, and then the optimal structure parameters with a significantly improved performance of the facility are obtained.

Keywords: MCNP simulation, PGNAA, Thai research reactor (TRR-1/M1), radiation shielding

Procedia PDF Downloads 383