Search results for: measurement validity
3299 Stray Light Reduction Methodology by a Sinusoidal Light Modulation and Three-Parameter Sine Curve Fitting Algorithm for a Reflectance Spectrometer
Authors: Hung Chih Hsieh, Cheng Hao Chang, Yun Hsiang Chang, Yu Lin Chang
Abstract:
In the applications of the spectrometer, the stray light that comes from the environment affects the measurement results a lot. Hence, environment and instrument quality control for the stray reduction is critical for the spectral reflectance measurement. In this paper, a simple and practical method has been developed to correct a spectrometer's response for measurement errors arising from the environment's and instrument's stray light. A sinusoidal modulated light intensity signal was incident on a tested sample, and then the reflected light was collected by the spectrometer. Since a sinusoidal signal modulated the incident light, the reflected light also had a modulated frequency which was the same as the incident signal. Using the three-parameter sine curve fitting algorithm, we can extract the primary reflectance signal from the total measured signal, which contained the primary reflectance signal and the stray light from the environment. The spectra similarity between the extracted spectra by this proposed method with extreme environment stray light is 99.98% similar to the spectra without the environment's stray light. This result shows that we can measure the reflectance spectra without the affection of the environment's stray light.Keywords: spectrometer, stray light, three-parameter sine curve fitting, spectra extraction
Procedia PDF Downloads 2513298 Study on Intensity Modulated Non-Contact Optical Fiber Vibration Sensors of Different Configurations
Authors: Dinkar Dantala, Kishore Putha, Padmavathi Manchineelu
Abstract:
Optical fibers are widely used in the measurement of several physical parameters like temperature, pressure, vibrations etc. Measurement of vibrations plays a vital role in machines. In this paper, three fiber optic non-contact vibration sensors were discussed, which are designed based on the principle of light intensity modulation. The Dual plastic optical fiber, Fiber optic fused 1x2 coupler and Fiber optic fused 2x2 coupler vibration sensors are compared based on range of frequency, resolution and sensitivity. It is to conclude that 2x2 coupler configuration shows better response than other two sensors.Keywords: fiber optic, PMMA, vibration sensor, intensity-modulated
Procedia PDF Downloads 3733297 Study on Concentration and Temperature Measurement with 760 nm Diode Laser in Combustion System Using Tunable Diode Laser Absorption Spectroscopy
Authors: Miyeon Yoo, Sewon Kim, Changyeop Lee
Abstract:
It is important to measure the internal temperature or temperature distribution precisely in combustion system to increase energy efficiency and reduce the pollutants. Especially in case of large combustion systems such as power plant boiler and reheating furnace of steel making process, it is very difficult to measure those physical properties in detail. Tunable diode laser absorption spectroscopy measurement and analysis can be attractive method to overcome the difficulty. In this paper, TDLAS methods are used to measure the oxygen concentration and temperature distribution in various experimental conditions.Keywords: tunable diode laser absorption Spectroscopy, temperature distribution, gas concentration
Procedia PDF Downloads 3873296 Reliability and Validity of a Portable Inertial Sensor and Pressure Mat System for Measuring Dynamic Balance Parameters during Stepping
Authors: Emily Rowe
Abstract:
Introduction: Balance assessments can be used to help evaluate a person’s risk of falls, determine causes of balance deficits and inform intervention decisions. It is widely accepted that instrumented quantitative analysis can be more reliable and specific than semi-qualitative ordinal scales or itemised scoring methods. However, the uptake of quantitative methods is hindered by expense, lack of portability, and set-up requirements. During stepping, foot placement is actively coordinated with the body centre of mass (COM) kinematics during pre-initiation. Based on this, the potential to use COM velocity just prior to foot off and foot placement error as an outcome measure of dynamic balance is currently being explored using complex 3D motion capture. Inertial sensors and pressure mats might be more practical technologies for measuring these parameters in clinical settings. Objective: The aim of this study was to test the criterion validity and test-retest reliability of a synchronised inertial sensor and pressure mat-based approach to measure foot placement error and COM velocity while stepping. Methods: Trials were held with 15 healthy participants who each attended for two sessions. The trial task was to step onto one of 4 targets (2 for each foot) multiple times in a random, unpredictable order. The stepping target was cued using an auditory prompt and electroluminescent panel illumination. Data was collected using 3D motion capture and a combined inertial sensor-pressure mat system simultaneously in both sessions. To assess the reliability of each system, ICC estimates and their 95% confident intervals were calculated based on a mean-rating (k = 2), absolute-agreement, 2-way mixed-effects model. To test the criterion validity of the combined inertial sensor-pressure mat system against the motion capture system multi-factorial two-way repeated measures ANOVAs were carried out. Results: It was found that foot placement error was not reliably measured between sessions by either system (ICC 95% CIs; motion capture: 0 to >0.87 and pressure mat: <0.53 to >0.90). This could be due to genuine within-subject variability given the nature of the stepping task and brings into question the suitability of average foot placement error as an outcome measure. Additionally, results suggest the pressure mat is not a valid measure of this parameter since it was statistically significantly different from and much less precise than the motion capture system (p=0.003). The inertial sensor was found to be a moderately reliable (ICC 95% CIs >0.46 to >0.95) but not valid measure for anteroposterior and mediolateral COM velocities (AP velocity: p=0.000, ML velocity target 1 to 4: p=0.734, 0.001, 0.000 & 0.376). However, it is thought that with further development, the COM velocity measure validity could be improved. Possible options which could be investigated include whether there is an effect of inertial sensor placement with respect to pelvic marker placement or implementing more complex methods of data processing to manage inherent accelerometer and gyroscope limitations. Conclusion: The pressure mat is not a suitable alternative for measuring foot placement errors. The inertial sensors have the potential for measuring COM velocity; however, further development work is needed.Keywords: dynamic balance, inertial sensors, portable, pressure mat, reliability, stepping, validity, wearables
Procedia PDF Downloads 1533295 Smart Energy Consumers: An Empirical Investigation on the Intention to Adopt Innovative Consumption Behaviour
Authors: Cecilia Perri, Vincenzo Corvello
Abstract:
The aim of the present study is to investigate consumers' determinants of intention toward the adoption of Smart Grid solutions and technologies. Ajzen's Theory of Planned Behaviour (TPB) model is applied and tested to explain the formation of such adoption intention. An exogenous variable, taking into account the resistance to change of individuals, was added to the basic model. The elicitation study allowed obtaining salient modal beliefs, which were used, with the support of literature, to design the questionnaire. After the screening phase, data collected from the main survey were analysed for evaluating measurement model's reliability and validity. Consistent with the theory, the results of structural equation analysis revealed that attitude, subjective norm, and perceived behavioural control positively, which affected the adoption intention. Specifically, the variable with the highest estimate loading factor was found to be the perceived behavioural control, and, the most important belief related to each construct was determined (e.g., energy saving was observed to be the most significant belief linked with attitude). Further investigation indicated that the added exogenous variable has a negative influence on intention; this finding confirmed partially the hypothesis, since this influence was indirect: such relationship was mediated by attitude. Implications and suggestions for future research are discussed.Keywords: adoption of innovation, consumers behaviour, energy management, smart grid, theory of planned behaviour
Procedia PDF Downloads 4093294 Gas Pressure Evaluation through Radial Velocity Measurement of Fluid Flow Modeled by Drift Flux Model
Authors: Aicha Rima Cheniti, Hatem Besbes, Joseph Haggege, Christophe Sintes
Abstract:
In this paper, we consider a drift flux mixture model of the blood flow. The mixture consists of gas phase which is carbon dioxide and liquid phase which is an aqueous carbon dioxide solution. This model was used to determine the distributions of the mixture velocity, the mixture pressure, and the carbon dioxide pressure. These theoretical data are used to determine a measurement method of mean gas pressure through the determination of radial velocity distribution. This method can be applicable in experimental domain.Keywords: mean carbon dioxide pressure, mean mixture pressure, mixture velocity, radial velocity
Procedia PDF Downloads 3253293 Blood Glucose Level Measurement from Breath Analysis
Authors: Tayyab Hassan, Talha Rehman, Qasim Abdul Aziz, Ahmad Salman
Abstract:
The constant monitoring of blood glucose level is necessary for maintaining health of patients and to alert medical specialists to take preemptive measures before the onset of any complication as a result of diabetes. The current clinical monitoring of blood glucose uses invasive methods repeatedly which are uncomfortable and may result in infections in diabetic patients. Several attempts have been made to develop non-invasive techniques for blood glucose measurement. In this regard, the existing methods are not reliable and are less accurate. Other approaches claiming high accuracy have not been tested on extended dataset, and thus, results are not statistically significant. It is a well-known fact that acetone concentration in breath has a direct relation with blood glucose level. In this paper, we have developed the first of its kind, reliable and high accuracy breath analyzer for non-invasive blood glucose measurement. The acetone concentration in breath was measured using MQ 138 sensor in the samples collected from local hospitals in Pakistan involving one hundred patients. The blood glucose levels of these patients are determined using conventional invasive clinical method. We propose a linear regression classifier that is trained to map breath acetone level to the collected blood glucose level achieving high accuracy.Keywords: blood glucose level, breath acetone concentration, diabetes, linear regression
Procedia PDF Downloads 1723292 An Efficiency Measurement of E-Government Performance for United Nation Ranking Index
Authors: Yassine Jadi, Lin Jie
Abstract:
In order to serve the society in an electronic manner, many developing countries have launched tremendous e-government projects. The strategies of development and implementation e-government system have reached different levels, and to ensure consistency of development, the governments need to evaluate e-government performance. The United nation has design e-government development ranking index (EGDI) that rely on three indexes, Online service index (OSI), Telecommunication Infrastructure index (TII), and human capital index( HCI) which are not reflecting the interaction between a government and their citizens. Based on data envelopment analyses (DEA) technique, we are using E-participating index (EPI) as an output of government effort to evaluate the performance of e-government system. Therefore, the ranking index can be achieved in efficiency manner.Keywords: e-government, DEA, efficiency measurement, EGDI
Procedia PDF Downloads 3763291 Alternate Approaches to Quality Measurement: An Exploratory Study in Differentiation of “Quality” Characteristics in Services and Supports
Authors: Caitlin Bailey, Marian Frattarola Saulino, Beth Steinberg
Abstract:
Today, virtually all programs offered to people with intellectual and developmental disabilities tout themselves as person-centered, community-based and inclusive, yet there is a vast range in type and quality of services that use these similar descriptors. The issue is exacerbated by the fields’ measurement practices around quality, inclusion, independent living, choice and person-centered outcomes. For instance, community inclusion for people with disabilities is often measured by the number of times person steps into his or her community. These measurement approaches set standards for quality too low so that agencies supporting group home residents to go bowling every week can report the same outcomes as an agency that supports one person to join a book club that includes people based on their literary interests rather than disability labels. Ultimately, lack of delineation in measurement contributes to the confusion between face value “quality” and true quality services and supports for many people with disabilities and their families. This exploratory study adopts alternative approaches to quality measurement including co-production methods and systems theoretical framework in order to identify the factors that 1) lead to high-quality supports and, 2) differentiate high-quality services. Project researchers have partnered with community practitioners who are all committed to providing quality services and supports but vary in the degree to which they are actually able to provide them. The study includes two parts; first, an online survey distributed to more than 500 agencies that have demonstrated commitment to providing high-quality services; and second, four in-depth case studies with agencies in three United States and Israel providing a variety of supports to children and adults with disabilities. Results from both the survey and in-depth case studies were thematically analyzed and coded. Results show that there are specific factors that differentiate service quality; however meaningful quality measurement practices also require that researchers explore the contextual factors that contribute to quality. These not only include direct services and interactions, but also characteristics of service users, their environments as well as organizations providing services, such as management and funding structures, culture and leadership. Findings from this study challenge researchers, policy makers and practitioners to examine existing quality service standards and measurements and to adopt alternate methodologies and solutions to differentiate and scale up evidence-based quality practices so that all people with disabilities have access to services that support them to live, work, and enjoy where and with whom they choose.Keywords: co-production, inclusion, independent living, quality measurement, quality supports
Procedia PDF Downloads 4003290 On-Chip Aging Sensor Circuit Based on Phase Locked Loop Circuit
Authors: Ararat Khachatryan, Davit Mirzoyan
Abstract:
In sub micrometer technology, the aging phenomenon starts to have a significant impact on the reliability of integrated circuits by bringing performance degradation. For that reason, it is important to have a capability to evaluate the aging effects accurately. This paper presents an accurate aging measurement approach based on phase-locked loop (PLL) and voltage-controlled oscillator (VCO) circuit. The architecture is rejecting the circuit self-aging effect from the characteristics of PLL, which is generating the frequency without any aging phenomena affects. The aging monitor is implemented in low power 32 nm CMOS technology, and occupies a pretty small area. Aging simulation results show that the proposed aging measurement circuit improves accuracy by about 2.8% at high temperature and 19.6% at high voltage.Keywords: aging effect, HCI, NBTI, nanoscale
Procedia PDF Downloads 3603289 Improving the Quality of Staff Performance with a Talent-Driven Approach: Case Study of SAIPA Automotive Manufacturing Company in Iran
Authors: Abdolmajid Mosleh, Afzal Ghasimi
Abstract:
The purpose of this research is to investigate and identify effective factors that can improve the quality of personal performance in industrial companies. In the present study, it was assumed that the hidden variables of talent management could be explained by an important part of the variance in improving the quality of employee performance. This research is targeted in terms of applied research. The statistical population of the research is SAIPA automobile company with a number (N=10291); the sample of 380 people was selected based on the Cochran formula in a random sampling method among employed people. The measurement tool in this research was a questionnaire of 33 items with a control questionnaire that included two talent management departments (talent identification and talent exploitation) and improvements in staff performance (enhancement of technical and specialized capabilities, managerial capability, organizational interaction, and communication). The reliability of the internal consistency method was confirmed by the Cronbach's alpha coefficient and the two half-ways. In order to determine the validity of the questionnaire structure, confirmatory factor analysis was used. Based on the results of the data analysis, the effect of talent management on improving the quality of staff performance was confirmed. Based on the results of inferential statistics and structural equations of the proposed model, it had high fitness.Keywords: employee performance, talent management, performance improvement, SAIPA automobile manufacturing company
Procedia PDF Downloads 923288 Virtual Assessment of Measurement Error in the Fractional Flow Reserve
Authors: Keltoum Chahour, Mickael Binois
Abstract:
Due to a lack of standardization during the invasive fractional flow reserve (FFR) procedure, the index is subject to many sources of uncertainties. In this paper, we investigate -through simulation- the effect of the (FFR) device position and configuration on the obtained value of the (FFR) fraction. For this purpose, we use computational fluid dynamics (CFD) in a 3D domain corresponding to a diseased arterial portion. The (FFR) pressure captor is introduced inside it with a given length and coefficient of bending to capture the (FFR) value. To get over the computational limitations, basically, the time of the simulation is about 2h 15min for one (FFR) value; we generate a Gaussian Process (GP) model for (FFR) prediction. The (GP) model indicates good accuracy and demonstrates the effective error in the measurement created by the random configuration of the pressure captor.Keywords: fractional flow reserve, Gaussian processes, computational fluid dynamics, drift
Procedia PDF Downloads 1383287 Online Measurement of Fuel Stack Elongation
Authors: Sung Ho Ahn, Jintae Hong, Chang Young Joung, Tae Ho Yang, Sung Ho Heo, Seo Yun Jang
Abstract:
The performances of nuclear fuels and materials are qualified at an irradiation system in research reactors operating under the commercial nuclear power plant conditions. Fuel centerline temperature, coolant temperature, neutron flux, deformations of fuel stack and swelling are important parameters needed to analyze the nuclear fuel performances. The dimensional stability of nuclear fuels is a key parameter measuring the fuel densification and swelling. In this study, the fuel stack elongation is measured using a LVDT. A mockup LVDT instrumented fuel rod is developed. The performances of mockup LVDT instrumented fuel rod is evaluated by experiments.Keywords: axial deformation, elongation measurement, in-pile instrumentation, LVDT
Procedia PDF Downloads 5343286 Neural Synchronization - The Brain’s Transfer of Sensory Data
Authors: David Edgar
Abstract:
To understand how the brain’s subconscious and conscious functions, we must conquer the physics of Unity, which leads to duality’s algorithm. Where the subconscious (bottom-up) and conscious (top-down) processes function together to produce and consume intelligence, we use terms like ‘time is relative,’ but we really do understand the meaning. In the brain, there are different processes and, therefore, different observers. These different processes experience time at different rates. A sensory system such as the eyes cycles measurement around 33 milliseconds, the conscious process of the frontal lobe cycles at 300 milliseconds, and the subconscious process of the thalamus cycle at 5 milliseconds. Three different observers experience time differently. To bridge observers, the thalamus, which is the fastest of the processes, maintains a synchronous state and entangles the different components of the brain’s physical process. The entanglements form a synchronous cohesion between the brain components allowing them to share the same state and execute in the same measurement cycle. The thalamus uses the shared state to control the firing sequence of the brain’s linear subconscious process. Sharing state also allows the brain to cheat on the amount of sensory data that must be exchanged between components. Only unpredictable motion is transferred through the synchronous state because predictable motion already exists in the shared framework. The brain’s synchronous subconscious process is entirely based on energy conservation, where prediction regulates energy usage. So, the eyes every 33 milliseconds dump their sensory data into the thalamus every day. The thalamus is going to perform a motion measurement to identify the unpredictable motion in the sensory data. Here is the trick. The thalamus conducts its measurement based on the original observation time of the sensory system (33 ms), not its own process time (5 ms). This creates a data payload of synchronous motion that preserves the original sensory observation. Basically, a frozen moment in time (Flat 4D). The single moment in time can then be processed through the single state maintained by the synchronous process. Other processes, such as consciousness (300 ms), can interface with the synchronous state to generate awareness of that moment. Now, synchronous data traveling through a separate faster synchronous process creates a theoretical time tunnel where observation time is tunneled through the synchronous process and is reproduced on the other side in the original time-relativity. The synchronous process eliminates time dilation by simply removing itself from the equation so that its own process time does not alter the experience. To the original observer, the measurement appears to be instantaneous, but in the thalamus, a linear subconscious process generating sensory perception and thought production is being executed. It is all just occurring in the time available because other observation times are slower than thalamic measurement time. For life to exist in the physical universe requires a linear measurement process, it just hides by operating at a faster time relativity. What’s interesting is time dilation is not the problem; it’s the solution. Einstein said there was no universal time.Keywords: neural synchronization, natural intelligence, 99.95% IoT data transmission savings, artificial subconscious intelligence (ASI)
Procedia PDF Downloads 1273285 Turkish Validation of the Nursing Outcomes for Urinary Incontinence and Their Sensitivities on Nursing Interventions
Authors: Dercan Gencbas, Hatice Bebis, Sue Moorhead
Abstract:
In the nursing process, many of the nursing classification systems were created to be used in international. From these, NANDA-I, Nursing Outcomes Classification (NOC) and Nursing Interventions Classification (NIC). In this direction, the main objective of this study is to establish a model for caregivers in hospitals and communities in Turkey and to ensure that nursing outputs are assessed by NOC-based measures. There are many scales to measure Urinary Incontinence (UI), which is very common in children, in old age, vaginal birth, NOC scales are ideal for use in the nursing process for comprehensive and holistic assessment, with surveys available. For this reason, the purpose of this study is to evaluate the validity of the NOC outputs and indicators used for UI NANDA-I. This research is a methodological study. In addition to the validity of scale indicators in the study, how much they will contribute to recovery after the nursing intervention was assessed by experts. Scope validations have been applied and calculated according to Fehring 1987 work model. According to this, nursing inclusion criteria and scores were determined. For example, if experts have at least four years of clinical experience, their score was 4 points or have at least one year of the nursing classification system, their score was 1 point. The experts were a publication experience about nursing classification, their score was 1 point, or have a doctoral degree in nursing, their score was 2 points. If the expert has a master degree, their score was 1 point. Total of 55 experts rated Fehring as a “senior degree” with a score of 90 according to the expert scoring. The nursing interventions to be applied were asked to what extent these indicators would contribute to recovery. For coverage validity tailored to Fehring's model, each NOC and NOC indicator from specialists was asked to score between 1-5. Score for the significance of indicators was from 1=no precaution to 5=very important. After the expert opinion, these weighted scores obtained for each NOC and NOC indicator were classified as 0.8 critical, 0.8 > 0.5 complements, > 0.5 are excluded. In the NANDA-I / NOC / NIC system (guideline), 5 NOCs proposed for nursing diagnoses for UI were proposed. These outputs are; Urinary Continence, Urinary Elimination, Tissue Integrity, Self CareToileting, Medication Response. After the scales are translated into Turkish, the weighted average of the scores obtained from specialists for the coverage of all 5 NOCs and the contribution of nursing initiatives exceeded 0.8. After the opinions of the experts, 79 of the 82 indicators were calculated as critical, 3 of the indicators were calculated as supplemental. Because of 0.5 > was not obtained, no substance was removed. All NOC outputs were identified as valid and usable scales in Turkey. In this study, five NOC outcomes were verified for the evaluation of the output of individuals who have received nursing knowledge of UI and variant types. Nurses in Turkey can benefit from the outputs of the NOC scale to perform the care of the elderly incontinence.Keywords: nursing outcomes, content validity, nursing diagnosis, urinary incontinence
Procedia PDF Downloads 1253284 Measurement of Temperature, Humidity and Strain Variation Using Bragg Sensor
Authors: Amira Zrelli, Tahar Ezzeddine
Abstract:
Measurement and monitoring of temperature, humidity and strain variation are very requested in great fields and areas such as structural health monitoring (SHM) systems. Currently, the use of fiber Bragg grating sensors (FBGS) is very recommended in SHM systems due to the specifications of these sensors. In this paper, we present the theory of Bragg sensor, therefore we try to measure the efficient variation of strain, temperature and humidity (SV, ST, SH) using Bragg sensor. Thus, we can deduce the fundamental relation between these parameters and the wavelength of Bragg sensor.Keywords: Fiber Bragg Grating Sensors (FBGS), strain, temperature, humidity, structural health monitoring (SHM)
Procedia PDF Downloads 3163283 Measuring Social Dimension of Sustainable Development in New Zealand Cities
Authors: Taimaz Larimian
Abstract:
During recent years, sustainable development has increasingly influenced urban policy, housing and planning in cities all over the world. Debates about sustainability no longer consider it solely as an environmental concern, but also incorporate social and economic dimensions. However, while a social dimension of sustainability is extensively accepted, the exact definition of the concept is still vague and unclear. This study is addressing this lack of specificity through a detailed exploration of social sustainability as the least studied pillar of sustainable development and sheds light on the debate over the definition of social sustainability through developing a measurement model of the constitutive dimensions of the concept. With this aim, a conceptual framework is developed based on the existing literature, determining seven main dimensions of the social sustainability concept namely: social interaction, safety and security, social equity, social participation, neighborhood satisfaction, housing satisfaction and sense of place. The validity and reliability of the model is then tested using exploratory and confirmatory factor analysis. In order to do so, five case study neighborhoods from Dunedin city with a range of urban forms and characters are investigated, to define social sustainability concept and its consisting dimensions from people’s perspective. The findings of this study present a clear definition of social sustainability at neighborhood scale and highlight all different dimensions of the concept in the context of New Zealand cities. According to the results, among the investigated dimensions, neighborhood satisfaction and safety and security had the most influence on people’s feeling of social sustainability in their neighborhood.Keywords: social sustainability, factor analysis, neighborhood level, New Zealand cities
Procedia PDF Downloads 3013282 Experimental and Finite Element Forming Limit Diagrams for Interstitial Free Steels
Authors: Basavaraj Vadavadagi, Satishkumar Shekhawat
Abstract:
Interstitial free steels posses better formability and have many applications in automotive industries. Forming limit diagrams (FLDs) indicate the formability of materials which can be determined by experimental and finite element (FE) simulations. FLDs were determined experimentally by LDH test, utilizing optical strain measurement system for measuring the strains in different width specimens and by FE simulations in Interstitial Free (IF) and Interstitial Free High Strength (IFHS) steels. In this study, the experimental and FE simulated FLDs are compared and also the stress based FLDs were investigated.Keywords: forming limit diagram, limiting dome height, optical strain measurement, interstitial
Procedia PDF Downloads 2333281 Memristive Properties of Nanostructured Porous Silicon
Authors: Madina Alimova, Margulan Ibraimov, Ayan Tileu
Abstract:
The paper describes methods for obtaining porous structures with the properties of a silicon-based memristor and explains the electrical properties of porous silicon films. Based on the results, there is a positive shift in the current-voltage characteristics (CVC) after each measurement, i.e., electrical properties depend not only on the applied voltage but also on the previous state. After 3 minutes of rest, the film returns to its original state (reset). The method for obtaining a porous silicon nanofilm with the properties of a memristor is simple and does not require additional effort. Based on the measurement results, the typical memristive behavior of the porous silicon nanofilm is analyzed.Keywords: porous silicon, current-voltage characteristics, memristor, nanofilms
Procedia PDF Downloads 1303280 The Readaptation of the Subscale 3 of the NLit-IT (Nutrition Literacy Assessment Instrument for Italian Subjects)
Authors: Virginia Vettori, Chiara Lorini, Vieri Lastrucci, Giulia Di Pisa, Alessia De Blasi, Sara Giuggioli, Guglielmo Bonaccorsi
Abstract:
The design of the Nutrition Literacy Assessment Instrument (NLit) responds to the need to provide a tool to adequately assess the construct of nutrition literacy (NL), which is strictly connected to the quality of the diet and nutritional health status. The NLit was originally developed and validated in the US context, and it was recently validated for Italian people too (NLit-IT), involving a sample of N = 74 adults. The results of the cross-cultural adaptation of the tool confirmed its validity since it was established that the level of NL contributed to predicting the level of adherence to the Mediterranean Diet (convergent validity). Additionally, results obtained proved that Internal Consistency and reliability of the NLit-IT were good (Cronbach’s alpha (ρT) = 0.78; 95% CI, 0.69–0.84; Intraclass Correlation Coefficient (ICC) = 0.68, 95% CI, 0.46–0.85). However, the Subscale 3 of the NLit-IT “Household Food Measurement” showed lower values of ρT and ICC (ρT = 0.27; 95% CI, 0.1–0.55; ICC = 0.19, 95% CI, 0.01–0.63) than the entire instrument. Subscale 3 includes nine items which are constituted by written questions and the corresponding pictures of the meals. In particular, items 2, 3, and 8 of Subscale 3 had the lowest level of correct answers. The purpose of the present study was to identify the factors that influenced the Internal Consistency and reliability of Subscale 3 of NLit-IT using the methodology of a focus group. A panel of seven experts was formed, involving professionals in the field of public health nutrition, dietetics, and health promotion and all of them were trained on the concepts of nutrition literacy and food appearance. A member of the group drove the discussion, which was oriented in the identification of the reasons for the low levels of reliability and Internal Consistency. The members of the group discussed the level of comprehension of the items and how they could be readapted. From the discussion, it emerges that the written questions were clear and easy to understand, but it was observed that the representations of the meal needed to be improved. Firstly, it has been decided to introduce a fork or a spoon as a reference dimension to better understand the dimension of the food portion (items 1, 4 and 8). Additionally, the flat plate of items 3 and 5 should be substituted with a soup plate because, in the Italian national context, it is common to eat pasta or rice on this kind of plate. Secondly, specific measures should be considered for some kind of foods such as the brick of yogurt instead of a cup of yogurt (items 1 and 4). Lastly, it has been decided to redo the photos of the meals basing on professional photographic techniques. In conclusion, we noted that the graphical representation of the items strictly influenced the level of participants’ comprehension of the questions; moreover, the research group agreed that the level of knowledge about nutrition and food portion size is low in the general population.Keywords: nutritional literacy, cross cultural adaptation, misinformation, food design
Procedia PDF Downloads 1723279 Validity and Reliability of Assessment of Language-Related Functional Activities: Evidence from Arab Aphasics
Authors: Sadeq Al Yaari, Nassr Almaflehi, Ayman Al Yaari, Adham Al Yaari, Montaha Al Yaari, Aayah Al Yaari, Sajedah Al Yaari
Abstract:
Background: Assessment of language-related functional activities (ALFA) is of vital importance in assessing aphasics’ performance of both sexes. However, the validity and reliability of this language therapeutic test has never been validated in the Arabic medical literature. Purpose: The aim of this study was to validate the test by assessing the language-related functional activities of 100 gender aphasics based in a medical faculty. Design: ALFA Pre-and-posttest was administered twice in three weeks to test the language-related functional activities of 100 gender aphasics. Settings: Al Khars hospital in Al Ahsa’a, Kingdom of Saudi Arabia (KSA). Participants: Sixteen to eight-year-old participants (N = 100 men and women) were enrolled in this experiment. Again, the purpose was to assess their language-related functional activities using ALFA. Procedures: The first step was to translate the English version of ALFA test into the mother tongue of the patients (Arabic). Secondly, the translated text is reviewed and edited by three specialists of Arabic language. Having the test standardized, the third step was to assess language-related functional activities of the participants in natural environment. Assessment took place in three weeks. In the first week, a pre-test was administered to the participants at hand and after two weeks, a post-test was administered to identify whether or not significant differences between the two tests (pre-and-posttest) could be observed. Interventions: Outcomes of the results obtained from the analyses were broadly discussed. Linguistic and statistical comparisons were held to illustrate the findings of this study. Main outcomes and Results: The analysis of the obtained results indicated that the performance of the aphasic participants in the post-test did not differ from that of the pre-test (, respectively). Conclusions & Implications: ALFA was proved to be a valid and reliable test. Moreover, outlined results pointed out the importance of assessing not only gender aphasics’ language, but also their language-related functional activities. Further research is needed to explore how gender aphasics’ verbal and non-verbal performances interact.Keywords: ALFA, language test, Arab aphasics, validity, reliability, psychoneurolinguistics.
Procedia PDF Downloads 493278 Comparison of Intraocular Pressure Measurement Prior and Following Full Intracorneal Ring Implantation in Patient with Keratoconus by Three Different Instruments
Authors: Seyed Aliasghar Mosavi, Mostafa Naderi, Khosrow Jadidi, Amir Hashem Mohammadi
Abstract:
To study the measurement of intraocular pressure (IOP) before and after implantation of intrastromal corneal ring (MyoRing) in patients with keratoconus. Setting: Baqiyatallah University of Medical Sciences, Tehran, Iran. Methods: We compared the IOP of 13 eyes which underwent MyoRing implantation prior and six months post operation using Goldman applanation (as gold standard), Icare, and Corvis ST (uncorrected, corrected and corrected with cornea biomechanics). Results: The resulting intraocular pressure measurements prior to surgery, Icare, Corvis (corrected with cornea biomechanics) overestimated the IOP, however measurements by Corvis uncorrected underestimate the IOP. The resulting intraocular pressure measurements after surgery, Icare, Corvis (corrected with cornea biomechanics) overestimated the IOP but measurements by Corvis uncorrected underestimate the IOP. Conclusion: Consistent intraocular pressure measurements on eyes with Myoring in keratoconus can be obtained with the Goldman applanation tonometer as the gold standard measurement. We were not able to obtain consistent results when we measured the IOP by Icare and Corvis prior and after surgery.Keywords: intraocular pressure, MyoRing, Keratoconus, Goldmann applanation, Icare, Corvis ST
Procedia PDF Downloads 2453277 Image Multi-Feature Analysis by Principal Component Analysis for Visual Surface Roughness Measurement
Authors: Wei Zhang, Yan He, Yan Wang, Yufeng Li, Chuanpeng Hao
Abstract:
Surface roughness is an important index for evaluating surface quality, needs to be accurately measured to ensure the performance of the workpiece. The roughness measurement based on machine vision involves various image features, some of which are redundant. These redundant features affect the accuracy and speed of the visual approach. Previous research used correlation analysis methods to select the appropriate features. However, this feature analysis is independent and cannot fully utilize the information of data. Besides, blindly reducing features lose a lot of useful information, resulting in unreliable results. Therefore, the focus of this paper is on providing a redundant feature removal approach for visual roughness measurement. In this paper, the statistical methods and gray-level co-occurrence matrix(GLCM) are employed to extract the texture features of machined images effectively. Then, the principal component analysis(PCA) is used to fuse all extracted features into a new one, which reduces the feature dimension and maintains the integrity of the original information. Finally, the relationship between new features and roughness is established by the support vector machine(SVM). The experimental results show that the approach can effectively solve multi-feature information redundancy of machined surface images and provides a new idea for the visual evaluation of surface roughness.Keywords: feature analysis, machine vision, PCA, surface roughness, SVM
Procedia PDF Downloads 2133276 Validation of the Female Sexual Function Index and the Female Sexual Distress Scale-Desire/Arousal/Orgasm in Chinese Women
Authors: Lan Luo, Jingjing Huang, Huafang Li
Abstract:
Introduction: Distressing low sexual desire is common in China, while the lack of reliable and valid instruments to evaluate symptoms of hypoactive sexual desire disorder (HSDD) impedes related research and clinical services. Aim: This study aimed to validate the reliability and validity of the Female Sexual Function Index (FSFI) and the Female Sexual Distress Scale-Desire/Arousal/Orgasm (FSDS-DAO) in Chinese female HSDD patients. Methods: We administered FSFI and FSDS-DAO in a convenient sample of Chinese adult women. Participants were diagnosed by a psychiatrist according to the Diagnostic and Statistical Manual of Mental Disorders, 4th Edition, Text Revision (DSM-IV-TR). Results: We had a valid analysis sample of 279 Chinese women, of which 107 were HSDD patients. The Cronbach's α of FSFI and FSDS-DAO were 0.947 and 0.956, respectively, and the intraclass correlation coefficients of which were 0.86 and 0.89, respectively (the interval was 13-15 days). The correlation coefficient between the Revised Adult Attachment Scale (RAAS) and FSFI (or FSDS-DAO) did not exceed 0.4; the area under the receiver operating characteristic (ROC) curve was 0. 83 when combined FSFI-d (the desire domain of FSFI) and FSDS-DAO to diagnose HSDD, which was significantly different from that of using these scales individually. FSFI-d of less than 2.7 (1.2-6) and FSDS-DAO of no less than 15 (0-60) (Sensitivity 65%, Specificity 83%), or FSFI-d of no more than 3.0 (1.2-6) and FSDS-DAO of no less than 14 (0-60) (Sensitivity 74%, Specificity 77%) can be used as cutoff scores in clinical research or outpatient screening. Clinical implications: FSFI (including FSFI-d) and FSDS-DAO are suitable for the screening and evaluation of Chinese female HSDD patients of childbearing age. Strengths and limitations: Strengths include a thorough validation of FSFI and FSDS-DAO and the exploration of the cutoff score combing FSFI-d and FSDS-DAO. Limitations include a small convenience sample and the requirement of being sexually active for HSDD patients. Conclusion: FSFI (including FSFI-d) and FSDS-DAO have good internal consistency, test-retest reliability, construct validity, and criterion validity in Chinese female HSDD patients of childbearing age.Keywords: sexual desire, sexual distress, hypoactive sexual desire disorder, scale
Procedia PDF Downloads 763275 Biosignal Measurement System Based on Ultra-Wide Band Human Body Communication
Authors: Jonghoon Kim, Gilwon Yoon
Abstract:
A wrist-band type biosignal measurement system and its data transfer through human body communication (HBC) were investigated. An HBC method based on pulses of ultra-wide band instead of using frequency or amplitude modulations was studied and implemented since the system became very compact and it was more suited for personal or mobile health monitoring. Our system measured photo-plethysmogram (PPG) and measured PPG signals were transmitted through a finger to a monitoring PC system. The device was compact and low-power consuming. HBC communication has very strong security measures since it does not use wireless network. Furthermore, biosignal monitoring system becomes handy because it does not need to have wire connections.Keywords: biosignal, human body communication, mobile health, PPG, ultrawide band
Procedia PDF Downloads 4763274 Development of a Force-Sensing Toothbrush for Gum Recession Measurement Using Programmable Automation Controller
Authors: Sorayya Kazemi, Hamed Kharrati, Mehdi Abedinpour Fallah
Abstract:
This paper presents the design and implementation of a novel electric pressure-sensitive toothbrush, capable of measuring the forces applied to the head of the brush. The developed device is used for gum recession measurement. In particular, the percentage of gum recession is measured by a Programmable Automation controller (PAC). Moreover, the brushing forces are measured by a Force Sensing Resistor (FSR) sensor. These forces are analog inputs of PAC. According to the applied forces during patient’s brushing and the patient’s percentage of gum recession, dentist sets the standard force range. The instrument alarms when the patient applies a force over the set range.Keywords: gum recession, force sensing resistor, controller, toothbrush
Procedia PDF Downloads 4973273 Development of a Performance Measurement Model for Hospitals Using Multi-Criteria Decision Making (MCDM) Techniques: A Case Study of Three South Australian Major Public Hospitals
Authors: Mohammad Safaeipour, Yousef Amer
Abstract:
This study directs its focus on developing a conceptual model to offer a systematic and integrated method to weigh the related measures and evaluate a competence of hospitals and rank of the selected hospitals that involve and consider the stakeholders’ key performance indicators (KPI’s). The Analytical Hierarchy Process (AHP) approach will use to weigh the dimensions and related sub- components. The weights and performance scores will combine by using the Technique for Order Performance by Similarity to Ideal Solution (TOPSIS) and rank the selected hospitals. The results of this study provide interesting insight into the necessity of process improvement implementation in which hospital that received the lowest ranking score.Keywords: performance measurement system, PMS, hospitals, AHP, TOPSIS
Procedia PDF Downloads 3743272 Assessment of Solid Insulating Material Using Partial Discharge Characteristics
Authors: Qasim Khan, Furkan Ahmad, Asfar A. Khan, M. Saad Alam, Faiz Ahmad
Abstract:
In this paper, partial discharge analysis is performed in cavities artificially created in insulation. The setup is according with Cigre-II Method. Circular Samples created from Perspex Sheet with different configuration with changing number of cavities. Assessment of insulation health can be performed by Partial Discharge measurement as this has been found to be important means of condition monitoring. The experiments are done using MPD 540, which is a modern partial discharge measurement system. By analyzing the PD activity obtained for various voids/cavities, it is observed that the PD voltages show variation for cavity’s diameter, depth even for its ratios. This can be employed for scrutiny of insulation system.Keywords: partial discharges, condition monitoring, insulation defects, degradation and corrosion, PMMA
Procedia PDF Downloads 5183271 Development and Psychometric Properties of the Dutch Contextual Assessment of Social Skills: A Blinded Observational Outcome Measure of Social Skills for Adolescents with Autism Spectrum Disorder
Authors: Sakinah Idris, Femke Ten Hoeve, Kirstin Greaves-Lord
Abstract:
Background: Social skills interventions are considered to be efficacious if social skills are improved as a result of an intervention. Nevertheless, the objective assessment of social skills is hindered by a lack of sensitive and validated measures. To measure the change in social skills after an intervention, questionnaires reported by parents, clinicians and/or teachers are commonly used. Observations are the most ecologically valid method of assessing improvements in social skills after an intervention. For this purpose, The Program for the Educational and Enrichment of Relational Skills (PEERS) was developed for adolescents, in order to teach them the age-appropriate skills needed to participate in society. It is an evidence-based intervention for adolescents with ASD that taught ecologically valid social skills techniques. Objectives: The current study aims to describe the development and psychometric evaluation of the Dutch Contextual Assessment of Social Skills (CASS), an observational outcome measure of social skills for adolescents with Autism Spectrum Disorder (ASD). Methods: 64 adolescents (M = 14.68, SD = 1.41, 71% boys) with ASD performed the CASS before and after a social skills intervention (i.e. PEERS or the active control condition). Each adolescent completed a 3-minute conversation with a confederate. The conversation was prompt as a natural introduction between two-unfamiliar, similar ages, opposite-sex peers who meet for the first time. The adolescent and the confederate completed a brief questionnaire about the conversation (Conversation Rating Scale). Results: Results indicated sufficient psychometric properties. The Dutch CASS has a high level of internal consistency (Cronbach's α coefficients = 0.84). Data supported the convergent validity (i.e., significant correlated with the Social Skills Improvement System (SSiS). The Dutch CASS did not significantly correlate with the autistic mannerism subscale from Social Responsiveness Scale (SRS), thus proved the divergent validity. Based on scorings made by raters who were kept blind to the time points, reliable change index was computed to assess the change in social skills. With regard to the content validity, only the learning objectives of the first two meetings of PEERS about conversational skills relatively matched with rating domains of the CASS. Due to this underrepresentation, we found an existing observational measure (TOPICC) that covers some of the other learning objectives of PEERS. TOPICC covers 22% of the learning objectives of PEERS about conversational skills, meanwhile, CASS is 45%. Unfortunately, 33% of the learning objectives of PEERS was not covered by CASS or TOPICC. Conclusion: Recommendations are made to improve the psychometric properties and content validity of the Dutch CASS.Keywords: autism spectrum disorder, observational, PEERS, social skills
Procedia PDF Downloads 1563270 Wheel Diameter and Width Influence in Variability of Brake Data Measurement at Ministry of Transport Facilities
Authors: Carolina Senabre, Sergio Valero, Emilio Velasco
Abstract:
The brake systems of vehicles are tested periodically by a “brake tester” at Ministry of Transport (MOT) stations. This tester measures the effectiveness of vehicle. This parameter is established by the International Committee of Vehicle Inspection (CITA). In this paper, we present an investigation of the influence of the tire size on the measurements of brake force on three MOT brake testers. We performed an analysis of the vehicle braking capacity test at MOT stations. The influence of varying wheel diameter and width on the measurement of braking at MOT stations has been analyzed. Thereby, the MOT brake tester as a verification system for a vehicle has been evaluated.Keywords: brake tester, ministry of transport facilities, wheel diameter, efficiency
Procedia PDF Downloads 376