Search results for: sensitivity analyses
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 5102

Search results for: sensitivity analyses

4952 Neural Network Mechanisms Underlying the Combination Sensitivity Property in the HVC of Songbirds

Authors: Zeina Merabi, Arij Dao

Abstract:

The temporal order of information processing in the brain is an important code in many acoustic signals, including speech, music, and animal vocalizations. Despite its significance, surprisingly little is known about its underlying cellular mechanisms and network manifestations. In the songbird telencephalic nucleus HVC, a subset of neurons shows temporal combination sensitivity (TCS). These neurons show a high temporal specificity, responding differently to distinct patterns of spectral elements and their combinations. HVC neuron types include basal-ganglia-projecting HVCX, forebrain-projecting HVCRA, and interneurons (HVC¬INT), each exhibiting distinct cellular, electrophysiological and functional properties. In this work, we develop conductance-based neural network models connecting the different classes of HVC neurons via different wiring scenarios, aiming to explore possible neural mechanisms that orchestrate the combination sensitivity property exhibited by HVCX, as well as replicating in vivo firing patterns observed when TCS neurons are presented with various auditory stimuli. The ionic and synaptic currents for each class of neurons that are presented in our networks and are based on pharmacological studies, rendering our networks biologically plausible. We present for the first time several realistic scenarios in which the different types of HVC neurons can interact to produce this behavior. The different networks highlight neural mechanisms that could potentially help to explain some aspects of combination sensitivity, including 1) interplay between inhibitory interneurons’ activity and the post inhibitory firing of the HVCX neurons enabled by T-type Ca2+ and H currents, 2) temporal summation of synaptic inputs at the TCS site of opposing signals that are time-and frequency- dependent, and 3) reciprocal inhibitory and excitatory loops as a potent mechanism to encode information over many milliseconds. The result is a plausible network model characterizing auditory processing in HVC. Our next step is to test the predictions of the model.

Keywords: combination sensitivity, songbirds, neural networks, spatiotemporal integration

Procedia PDF Downloads 36
4951 Delamination of Scale in a Fe Carbon Steel Surface by Effect of Interface Roughness and Oxide Scale Thickness

Authors: J. M. Lee, W. R. Noh, C. Y. Kim, M. G. Lee

Abstract:

Delamination of oxide scale has been often discovered at the interface between Fe carbon steel and oxide scale. Among several mechanisms of this delamination behavior, the normal tensile stress to the substrate-scale interface has been described as one of the main factors. The stress distribution at the interface is also known to be affected by thermal expansion mismatch between substrate and oxide scale, creep behavior during cooling and the geometry of the interface. In this study, stress states near the interface in a Fe carbon steel with oxide scale have been investigated using FE simulations. The thermal and mechanical properties of oxide scales are indicated in literature and Fe carbon steel is measured using tensile testing machine. In particular, the normal and shear stress components developed at the interface during bending are investigated. Preliminary numerical sensitivity analyses are provided to explain the effects of the interface geometry and oxide thickness on the delamination behavior.

Keywords: oxide scale, delamination, Fe analysis, roughness, thickness, stress state

Procedia PDF Downloads 317
4950 Utility of the Loop-Mediated Isothermal Amplification Assay for the Diagnosis of Visceral Leishmaniasis from Blood Samples in Ethiopia

Authors: Dawit Gebreegzabher Hagos, Yazezew Kebede Kiro, Mahmud Abdulkader, Henk H. D. F. Schallig, Dawit Wolday

Abstract:

Rapid and accurate visceral leishmaniasis (VL) diagnosis is needed to initiate prompt treatment to reduce morbidity and mortality. Here, we evaluated the performance of loop-mediated isothermal amplification (LAMP) assay for the diagnosis of VL from blood in an endemic area in Ethiopia. LAMP was positive in 117/122 confirmed VL cases and negative in 149/152 controls, resulting in a sensitivity of 95.9% (95% CI: 90.69–98.66) and a specificity of 98.0% (95% CI: 94.34–99.59), respectively. The sensitivity of the LAMP assay was 95.0% (95% CI: 88.61–98.34) in HIV-negatives and 100% (95% CI: 85.18–100.0) in HIV-positives. Compared with microscopy, LAMP detected 82/87 (94.3%, 95% CI: 87.10–98.11) of the microscopy1 cases and was negative in 11/27 (40.7%, 95% CI: 22.39–61.20) of the microscopy2 cases. Compared with the rK39 serology, LAMP detected 113/120 (94.2%, 95% CI: 88.35–97.62) of the rK391 cases and was negative in 149/154 (96.8%, 95% CI: 92.59–98.94) of the rK392 cases. However, when compared with microscopy only, rK39 detected 83/87 (95.4%, 95% CI: 88.64–98.73) of the microscopy1 cases and negative in only 12/27 (44.4%, 95% CI: 25.48–64.67) of the microscopy– cases. There was an excellent agreement between rK39 and LAMP (Kappa 5 0.91, 95% CI: 0.86–0.96). Furthermore, an algorithm using rK39 followed by LAMP would yield a sensitivity of 99.2% (95%CI: 95.52–99.89) and a specificity of 98.0% (95% CI: 94.34–99.59). The findings demonstrate that the LAMP assay is an accurate and rapid molecular assay for VL diagnosis, including in HIV-1 co-infected patients, in an endemic setting.

Keywords: visceral leishmaniasis, HIV, diagnosis, LAMP, Ethiopia

Procedia PDF Downloads 62
4949 Powder Flow with Normalized Powder Particles Size Distribution and Temperature Analyses in Laser Melting Deposition: Analytical Modelling and Experimental Validation

Authors: Muhammad Arif Mahmood, Andrei C. Popescu, Mihai Oane, Diana Chioibascu, Carmen Ristoscu, Ion N. Mihailescu

Abstract:

Powder flow and temperature distributions are recognized as influencing factors during laser melting deposition (LMD) process, that not only affect the consolidation rate but also characteristics of the deposited layers. Herewith, two simplified analytical models will be presented to simulate the powder flow with the inclusion of powder particles size distribution in Gaussian form, under three powder jet nozzles, and temperature analyses during LMD process. The output of the 1st model will serve as the input in the 2nd model. The models will be validated with experimental data, i.e., weight measurement method for powder particles distribution and infrared imaging for temperature analyses. This study will increase the cost-efficiency of the LMD process by adjustment of the operating parameters for reaching optimal powder debit and energy. This research has received funds under the Marie Sklodowska-Curie grant agreement No. 764935, from the European Union’s Horizon 2020 research and innovation program.

Keywords: laser additive manufacturing, powder particles size distribution in Gaussian form, powder stream distribution, temperature analyses

Procedia PDF Downloads 109
4948 Contribution to the Study of the Microbiological Quality of Chawarma Sold in Biskra

Authors: Sara Boulmai̇z

Abstract:

In order to study the microbiological quality of chawarma sold in Biskra, a sampling through some fastfoods of the city was done, the parameters studied are highlighted according to the criteria required by the country's trade management. Microbiological analyzes revealed different levels of contamination by microorganisms. The 10 samples were of an overall view of unsatisfactory quality, and according to the standards, no sample was satisfactory. The range of total aerobic mesophilic flora found is between 105 and 1.2 × 10 7 CFU / g, that of fecal coliforms is 104 to 2.4 × 10 5 CFU / g. The suspected pathogenic staphylococci were between 3.103 and 2.7.106 CFU / g. Salmonellae were absent in all samples, whereas sulphite-reducing anaerobes were present in a single sample. The rate of E. cloacae was between 103 and 6.104 CFU / g. As for fungi and safe mice, their rate was 103 to 107 CFU / g. The study of the sensitivity of antibiotics showed multi-resistance to all the antibiotics tested, although there is a sensitivity towards others. All strains of Staphylococcus aureus tested demonstrated resistance against erythromycin, 30% against streptomycin, and 10% against tetracycline. While the strains of E. cloacae were resistant in all strains to amoxicillin, ceftazidime, cefotaxime, and erythromycin, while they were sensitive to fosfomycin, sulfamethoxazole trimethoperine, ciprofloxacin, and tetracycline. While against chlorophenicol and ofloxacin, the sensitivity was dominant, although there was intermediate resistance. In this study demonstrates that foodborne illnesses remain a problem that arises in addition to the increasingly observed bacterial resistance and that, after all, healthy eating is a right.

Keywords: chawarma, microbiological quality, pathogens., street food

Procedia PDF Downloads 82
4947 Cross-Layer Design of Event-Triggered Adaptive OFDMA Resource Allocation Protocols with Application to Vehicle Clusters

Authors: Shaban Guma, Naim Bajcinca

Abstract:

We propose an event-triggered algorithm for the solution of a distributed optimization problem by means of the projected subgradient method. Thereby, we invoke an OFDMA resource allocation scheme by applying an event-triggered sensitivity analysis at the access point. The optimal resource assignment of the subcarriers to the involved wireless nodes is carried out by considering the sensitivity analysis of the overall objective function as defined by the control of vehicle clusters with respect to the information exchange between the nodes.

Keywords: consensus, cross-layer, distributed, event-triggered, multi-vehicle, protocol, resource, OFDMA, wireless

Procedia PDF Downloads 303
4946 Sensitivity and Specificity of Clinical Testing for Digital Nerve Injury

Authors: Guy Rubin, Ravit Shay, Nimrod Rozen

Abstract:

The accuracy of a diagnostic test used to classify a patient as having disease or being disease-free is a valuable piece of information to be used by the physician when making treatment decisions. Finger laceration, suspected to have nerve injury is a challenging decision for the treating surgeon. The purpose of this study was to evaluate the sensitivity, specificity and predictive values of six clinical tests in the diagnosis of digital nerve injury. The six clinical tests included light touch, pin prick, static and dynamic 2-point discrimination, Semmes Weinstein monofilament and wrinkle test. Data comparing pre-surgery examination with post-surgery results of 42 patients with 52 digital nerve injury was evaluated. The subjective examinations, light touch, pin prick, static and dynamic 2-point discrimination and Semmes-Weinstein monofilament were not sensitive (57.6, 69.7, 42.4, 40 and 66.8% respectively) and specific (36.8, 36.8, 47.4, 42.1 and 31.6% respectively). Wrinkle test, the only objective examination, was the most sensitive (78.1%) and specific (55.6%). This result gives no pre-operative examination the ability to predict the result of explorative surgery.

Keywords: digital nerve, injury, nerve examination, Semmes-Weinstein monofilamen, sensitivity, specificity, two point discrimination, wrinkle test

Procedia PDF Downloads 303
4945 Comparison of Sensitivity and Specificity of Pap Smear and Polymerase Chain Reaction Methods for Detection of Human Papillomavirus: A Review of Literature

Authors: M. Malekian, M. E. Heydari, M. Irani Estyar

Abstract:

Human papillomavirus (HPV) is one of the most common sexually transmitted infection, which may lead to cervical cancer as the main cause of it. With early diagnosis and treatment in health care services, cervical cancer and its complications are considered to be preventable. This study was aimed to compare the efficiency, sensitivity, and specificity of Pap smear and polymerase chain reaction (PCR) in detecting HPV. A literature search was performed in Google Scholar, PubMed and SID databases using the keywords 'human papillomavirus', 'pap smear' and 'polymerase change reaction' to identify studies comparing Pap smear and PCR methods for the detection. No restrictions were considered.10 studies were included in this review. All samples that were positive by pop smear were also positive by PCR. However, there were positive samples detected by PCR which was negative by pop smear and in all studies, many positive samples were missed by pop smear technique. Although The Pap smear had high specificity, PCR based HPV detection was more sensitive method and had the highest sensitivity. In order to promote the quality of detection and high achievement of the maximum results, PCR diagnostic methods in addition to the Pap smear are needed and Pap smear method should be combined with PCR techniques according to the high error rate of Pap smear in detection.

Keywords: human papillomavirus, cervical cancer, pap smear, polymerase chain reaction

Procedia PDF Downloads 107
4944 An Investigation on Electric Field Distribution around 380 kV Transmission Line for Various Pylon Models

Authors: C. F. Kumru, C. Kocatepe, O. Arikan

Abstract:

In this study, electric field distribution analyses for three pylon models are carried out by a Finite Element Method (FEM) based software. Analyses are performed in both stationary and time domains to observe instantaneous values along with the effective ones. Considering the results of the study, different line geometries is considerably affecting the magnitude and distribution of electric field although the line voltages are the same. Furthermore, it is observed that maximum values of instantaneous electric field obtained in time domain analysis are quite higher than the effective ones in stationary mode. In consequence, electric field distribution analyses should be individually made for each different line model and the limit exposure values or distances to residential buildings should be defined according to the results obtained.

Keywords: electric field, energy transmission line, finite element method, pylon

Procedia PDF Downloads 701
4943 The Relationship between Sleep Traits and Tinnitus in UK Biobank: A Population-Based Cohort Study

Authors: Jiajia Peng, Yijun Dong, Jianjun Ren, Yu Zhao

Abstract:

Objectives: Understanding the association between sleep traits and tinnitus could help prevent and provide appropriate interventions against tinnitus. Therefore, this study aimed to assess the relationship between different sleep patterns and tinnitus. Design: A cross-sectional analysis using baseline data (2006–2010, n=168,064) by logistic regressions was conducted to evaluate the association between sleep traits (including the overall health sleep score and five sleep behaviors), and the occurrence (yes/no), frequency (constant/transient), and severity (upsetting/not upsetting) of tinnitus. Further, a prospective analysis of participants without tinnitus at baseline (n=9,581) was performed, who had been followed up for seven years (2012–2019) to assess the association between new-onset tinnitus and sleep characteristics. Moreover, a subgroup analysis was also carried out to estimate the differences in sex by dividing the participants into male and female groups. A sensitivity analysis was also conducted by excluding ear-related diseases to avoid their confounding effects on tinnitus (n=102,159). Results: In the cross-sectional analysis, participants with “current tinnitus” (OR: 1.13, 95% CI: 1.04–1.22, p=0.004) had a higher risk of having a poor overall healthy sleep score and unhealthy sleep behaviors such as short sleep durations (OR: 1.09, 95% CI: 1.04–1.14, p<0.001), late chronotypes (OR: 1.09, 95% CI: 1.05–1.13, p<0.001), and sleeplessness (OR: 1.16, 95% CI: 1.11–1.22, p<0.001) than those participants who “did not have current tinnitus.” However, this trend was not obvious between “constant tinnitus” and “transient tinnitus.” When considering the severity of tinnitus, the risk of “upsetting tinnitus” was obviously higher if participants had lower overall healthy sleep scores (OR: 1.31, 95% CI: 1.13–1.53, p<0.001). Additionally, short sleep duration (OR: 1.22, 95% CI: 1.12–1.33, p<0.001), late chronotypes (OR: 1.13, 95% CI: 1.04–1.22, p=0.003), and sleeplessness (OR: 1.43, 95% CI: 1.29–1.59, p<0.001) showed positive correlations with “upsetting tinnitus.” In the prospective analysis, sleeplessness presented a consistently significant association with “upsetting tinnitus” (RR: 2.28, P=0.001). Consistent results were observed in the sex subgroup analysis, where a much more pronounced trend was identified in females compared with males. The results of the sensitivity analysis were consistent with those of the cross-sectional and prospective analyses. Conclusions: Different types of sleep disturbance may be associated with the occurrence and severity of tinnitus; therefore, precise interventions for different types of sleep disturbance, particularly sleeplessness, may help in the prevention and treatment of tinnitus.

Keywords: tinnitus, sleep, sleep behaviors, sleep disturbance

Procedia PDF Downloads 101
4942 Clinical Trial of VEUPLEXᵀᴹ TBI Assay to Help Diagnose Traumatic Brain Injury by Quantifying Glial Fibrillary Acidic Protein and Ubiquitin Carboxy-Terminal Hydrolase L1 in the Serum of Patients Suspected of Mild TBI by Fluorescence Immunoassay

Authors: Moon Jung Kim, Guil Rhim

Abstract:

The clinical sensitivity of the “VEUPLEXTM TBI assay”, a clinical trial medical device, in mild traumatic brain injury was 28.6% (95% CI, 19.7%-37.5%), and the clinical specificity was 94.0% (95% CI, 89.3%). -98.7%). In addition, when the results analyzed by marker were put together, the sensitivity was higher when interpreting the two tests together than the two tests, UCHL1 and GFAP alone. Additionally, when sensitivity and specificity were analyzed based on CT results for the mild traumatic brain injury patient group, the clinical sensitivity for 2 CT-positive cases was 50.0% (95% CI: 1.3%-98.7%), and 19 CT-negative cases. The clinical specificity for cases was 68.4% (95% CI: 43.5% - 87.4%). Since the low clinical sensitivity for the two CT-positive cases was not statistically significant due to the small number of samples analyzed, it was judged necessary to secure and analyze more samples in the future. Regarding the clinical specificity analysis results for 19 CT-negative cases, there were a large number of patients who were actually clinically diagnosed with mild traumatic brain injury but actually received a CT-negative result, and about 31.6% of them showed abnormal results on VEUPLEXTM TBI assay. Although traumatic brain injury could not be detected in 31.6% of the CT scans, the possibility of actually suffering a mild brain injury could not be ruled out, so it was judged that this could be confirmed through follow-up observation of the patient. In addition, among patients with mild traumatic brain injury, CT examinations were not performed in many cases because the symptoms were very mild, but among these patients, about 25% or more showed abnormal results in the VEUPLEXTM TBI assay. In fact, no damage is observed with the naked eye immediately after traumatic brain injury, and traumatic brain injury is not observed even on CT. But in some cases, brain hemorrhage may occur (delayed cerebral hemorrhage) after a certain period of time, so the patients who did show abnormal results on VEUPLEXTM TBI assay should be followed up for the delayed cerebral hemorrhage. In conclusion, it was judged that it was difficult to judge mild traumatic brain injury with the VEUPLEXTM TBI assay only through clinical findings without CT results, that is, based on the GCS value. Even in the case of CT, it does not detect all mild traumatic brain injury, so it is difficult to necessarily judge that there is no traumatic brain injury, even if there is no evidence of traumatic brain injury in CT. And in the long term, more patients should be included to evaluate the usefulness of the VEUPLEXTM TBI assay in the detection of microscopic traumatic brain injuries without using CT.

Keywords: brain injury, traumatic brain injury, GFAP, UCHL1

Procedia PDF Downloads 52
4941 Effect of 8 Weeks of Intervention on Physical Fitness, Hepatokines, and Insulin Resistance in Obese Subjects

Authors: Adela Penesova, Zofia Radikova, Boris Bajer, Andrea Havranova, Miroslav Vlcek

Abstract:

Background: The aim of our study was to compare the effect of intensified lifestyle intervention on insulin resistance (HOMA-IR), alanine aminotransferase (ALT), aspartate aminotransferase (AST), and Fibroblast growth factor (FGF) 21 after 8 weeks of lifestyle intervention. Methods: A group of 43 obese patients (13M/30F; 43.0±12.4 years; BMI (body mass index) 31.2±6.3 kg/m2 participated in a weight loss interventional program (NCT02325804) following an 8-week hypocaloric diet (-30% energy expenditure) and physical activity 150 minutes/week. Insulin sensitivity was evaluated according to the homeostasis model assessment of insulin resistance (HOMA-IR) and insulin sensitivity indices according to Matsuda and Cederholm were calculated (ISImat and ISIced). Plasma ALT, AST, Fetuin-A, FGF 21, and physical fitness were measured. Results: The average reduction of body weight was 6.8±4.9 kg (0-15 kg; p=0.0006), accompanied with a significant reduction of body fat amount of fat mass (p=0.03), and waist circumference (p=0.02). Insulin sensitivity has been improved (IR HOMA 2.71±3.90 vs 1.24±0.83; p=0.01; ISIMat 6.64±4.38 vs 8.93±5.36 p ≤ 0.001). Total, LDL cholesterol, and triglycerides decreased (p=0.05, p=0.04, p=0.04, respectively). Physical fitness significantly improved after intervention (as measure VO2 max (maximal oxygen uptake) (p ≤ 0.001). ALT decreased significantly (0.44±0.26 vs post 0.33±0.18 ukat/l, p=0.004); however, AST not (pre 0.40±0.15 vs 0.35±0.09 ukat/l, p=0.07). Hepatokine Fetuin-A significantly decreased after intervention (43.1±10.8 vs 32.6±8.6 ng/ml, p < 0.001); however, FGF 21 levels tended to decrease (146±152 vs 132±164 pg/ml, p=0.07). Conclusion: 8-weeks of diet and physical activity intervention program in obese otherwise healthy subjects led to an improvement of insulin resistance parameters and liver marker profiles, as well as increased physical fitness. This study was supported by grants APVV 15-0228; VEGA 2/0161/16.

Keywords: obesity, diet, exercice, insulin sensitivity

Procedia PDF Downloads 172
4940 Modeling and Analysis of Laser Sintering Process Scanning Time for Optimal Planning and Control

Authors: Agarana Michael C., Akinlabi Esther T., Pule Kholopane

Abstract:

In order to sustain the advantages of an advanced manufacturing technique, such as laser sintering, minimization of total processing cost of the parts being produced is very important. An efficient time management would usually very important in optimal cost attainment which would ultimately result in an efficient advanced manufacturing process planning and control. During Laser Scanning Process Scanning (SLS) procedures it is possible to adjust various manufacturing parameters which are used to influence the improvement of various mechanical and other properties of the products. In this study, Modelling and mathematical analysis, including sensitivity analysis, of the laser sintering process time were carried out. The results of the analyses were represented with graphs, from where conclusions were drawn. It was specifically observed that achievement of optimal total scanning time is key for economic efficiency which is required for sustainability of the process.

Keywords: modeling and analysis, optimal planning and control, laser sintering process, scanning time

Procedia PDF Downloads 75
4939 The MoEDAL-MAPP* Experiment - Expanding the Discovery Horizon of the Large Hadron Collider

Authors: James Pinfold

Abstract:

The MoEDAL (Monopole and Exotics Detector at the LHC) experiment deployed at IP8 on the Large Hadron Collider ring was the first dedicated search experiment to take data at the Large Hadron Collider (LHC) in 2010. It was designed to search for Highly Ionizing Particle (HIP) avatars of new physics such as magnetic monopoles, dyons, Q-balls, multiply charged particles, massive, slowly moving charged particles and long-lived massive charge SUSY particles. We shall report on our search at LHC’s Run-2 for Magnetic monopoles and dyons produced in p-p and photon-fusion. In more detail, we will report our most recent result in this arena: the search for magnetic monopoles via the Schwinger Mechanism in Pb-Pb collisions. The MoEDAL detector, originally the first dedicated search detector at the LHC, is being reinstalled for LHC’s Run-3 to continue the search for electrically and magnetically charged HIPs with enhanced instantaneous luminosity, detector efficiency and a factor of ten lower thresholds for HIPs. As part of this effort, we will search for massive l long-lived, singly and multiply charged particles from various scenarios for which MoEDAL has a competitive sensitivity. An upgrade to MoEDAL, the MoEDAL Apparatus for Penetrating Particles (MAPP), is now the LHC’s newest detector. The MAPP detector, positioned in UA83, expands the physics reach of MoEDAL to include sensitivity to feebly-charged particles with charge, or effective charge, as low as 10-3 e (where e is the electron charge). Also, In conjunction with MoEDAL’s trapping detector, the MAPP detector gives us a unique sensitivity to extremely long-lived charged particles. MAPP also has some sensitivity to long-lived neutral particles. The addition of an Outrigger detector for MAPP-1 to increase its acceptance for more massive milli-charged particles is currently in the Technical Proposal stage. Additionally, we will briefly report on the plans for the MAPP-2 upgrade to the MoEDAL-MAPP experiment for the High Luminosity LHC (HL-LHC). This experiment phase is designed to maximize MoEDAL-MAPP’s sensitivity to very long-lived neutral messengers of physics beyond the Standard Model. We envisage this detector being deployed in the UGC1 gallery near IP8.

Keywords: LHC, beyond the standard model, dedicated search experiment, highly ionizing particles, long-lived particles, milli-charged particles

Procedia PDF Downloads 42
4938 Reliability-Based Design of an Earth Slope Taking into Account Unsaturated Soil Properties

Authors: A. T. Siacara, A. T. Beck, M. M. Futai

Abstract:

This paper shows how accurately and efficiently reliability analyses of geotechnical installations can be performed by directly coupling geotechnical software with a reliability solver. An earth slope is used as the study object. The limit equilibrium method of Morgenstern-Price is used to calculate factors of safety and find the critical slip surface. The deterministic software package Seep/W and Slope/W is coupled with the StRAnD reliability software. Reliability indexes of critical probabilistic surfaces are evaluated by the first-order reliability methods (FORM). By means of sensitivity analysis, the effective cohesion (c') is found to be the most relevant uncertain geotechnical parameter for slope equilibrium. The slope was tested using different geometries, taking into account unsaturated soil properties. Finally, a critical slip surface, identified in terms of minimum factor of safety, is shown here not to be the critical surface in terms of reliability index.

Keywords: slope, unsaturated, reliability, safety, seepage

Procedia PDF Downloads 116
4937 Air Pollutants Exposure and Blood High Sensitivity C-Reactive Protein Concentrations in Healthy Pregnant Women

Authors: Gwo-Hwa Wan, Tai-Ho Hung, Fen-Fang Chung, Wan-Ying Lee, Hui-Ching Yang

Abstract:

Air pollutant exposure results in elevated concentrations of oxidative stress and inflammatory biomarkers in general populations. Increased concentrations of inflammatory biomarkers in pregnant women would be associated with preterm labor and low birth weight. To our best knowledge, the associations between air pollutants exposure and inflammation in pregnant women and fetuses are unknown, as well as their effects on fetal growth. This study aimed to evaluate the influences of outdoor air pollutants in northern Taiwan areas on the inflammatory biomarker (high sensitivity C-reactive protein, hs-CRP) concentration in the blood of healthy pregnant women and how the biomarker impacts fetal growth. In this study, 38 healthy pregnant women who are in their first trimester and live in northern Taiwan area were recruited from the Taipei Chang Gung Memorial Hospital. Personal characteristics and prenatal examination data (e.g., blood pressure) were obtained from recruited subjects. The concentrations of inflammatory mediators, hs-CRP, in the blood of healthy pregnant women were analyzed. Additionally, hourly data of air pollutants (PM10, SO2, NO2, O3, CO) concentrations were obtained from air quality monitoring stations in Taipei area, established by the Taiwan Environmental Protection Administration. The definition of lag 0 and lag 01 are the exposure to air pollutants on the day of blood withdrawal, and the average exposure to air pollutants one day before and on the day of blood withdrawal, respectively. The statistical analyses were conducted using SPSS software version 22.0 (SPSS, Inc., Chicago, IL, USA). This analytical result indicates that the healthy pregnant women aged between 28 and 42 years old. The body mass index before pregnancy averaged 21.51 (sd = 2.51) kg/m2. Around 90% of the pregnant women had never smoking habit, and 28.95% of them had allergic diseases. Approximately around 84% and 5.26% of the pregnant women worked at indoor and outdoor environments, respectively. The mean hematocrit level of the pregnant women was 37.10%, and the hemoglobin levels were ranged between 10.1 and 14.7 g/dL with 12.47 g/dL of mean value. The blood hs-CRP concentrations of healthy pregnant women in the first trimester ranged between 0.32 and 32.5 mg/L with 2.83 (sd = 5.69) mg/L of mean value. The blood hs-CRP concentrations were positively associated with ozone concentrations at lag 0-14 (r = 0.481, p = 0.017) in healthy pregnant women. Significant lag effects were identified in ozone at lag 0-14 with a positive excess concentration of blood hs-CRP.

Keywords: air pollutant, hs-CRP, pregnant woman, ozone, first trimester

Procedia PDF Downloads 233
4936 Carbon Nanofilms on Diamond for All-Carbon Chemical Sensors

Authors: Vivek Kumar, Alexander M. Zaitsev

Abstract:

A study on chemical sensing properties of carbon nanofilms on diamond for developing all-carbon chemical sensors is presented. The films were obtained by high temperature graphitization of diamond followed by successive plasma etchings. Characterization of the films was done by Raman spectroscopy, atomic force microscopy, and electrical measurements. Fast and selective response to common organic vapors as seen as sensitivity of electrical conductance was observed. The phenomenological description of the chemical sensitivity is proposed as a function of the surface and bulk material properties of the films.

Keywords: chemical sensor, carbon nanofilm, graphitization of diamond, plasma etching, Raman spectroscopy, atomic force microscopy

Procedia PDF Downloads 420
4935 The Next Generation Neutrinoless Double-Beta Decay Experiment nEXO

Authors: Ryan Maclellan

Abstract:

The nEXO Collaboration is designing a very large detector for neutrinoless double beta decay of Xe-136. The nEXO detector is rooted in the current EXO-200 program, which has reached a sensitivity for the half-life of the decay of 1.9x10^25 years with an exposure of 99.8 kg-y. The baseline nEXO design assumes 5 tonnes of liquid xenon, enriched in the mass 136 isotope, within a time projection chamber. The detector is being designed to reach a half-life sensitivity of > 5x10^27 years covering the inverted neutrino mass hierarchy, with 5 years of data. We present the nEXO detector design, the current status of R&D efforts, and the physics case for the experiment.

Keywords: double-beta, Majorana, neutrino, neutrinoless

Procedia PDF Downloads 395
4934 Developing of Attitude towards Using Complementary Treatments Scale in Turkey

Authors: Ayşegül Bilge, Merve Uğuryol, Şeyda Dülgerler, Mustafa Yıldız

Abstract:

The purpose of this research is to prove the Attitude towards Using Complementary Treatments Scale reliability and validity. The research is a methodological type of research that has been planned to determine the validity and reliability of the Attitude towards Using Complementary Treatments Scale. The scale has been developed by the researchers. In the scale, there are 23 questions including complementary and modern therapies individuals apply when they have health problems 4-item Likert-type evaluation has been carried out in preparing the questionnaire. High score obtained from the scale indicates a positive attitude towards complementary therapies. In the course of validity assessment of the scale, expert opinion has been received, and the content validity of the scale has been determined by using Kendall coefficient correlation test (Wa=0.200, p = 0.460). In the course of the reliability assessment of the scale, total score correlations of 23 materials have been examined, and those under 0.20 correlation limit has been removed from the scale correlation. As a result, the scale was left to be 13 items. In the internal consistency tests of the analyses, Cronbach's alpha value has been found to be 0.79. As a result, of the validity analyses of the Attitude towards Using Complementary Treatments Scale, the content and language validity analyses has been found to be at the expected level. It has been determined to be a highly reliable scale as the result of the reliability analyses. In conclusion, Attitude towards Using Complementary Treatments Scale is a valid and reliable scale.

Keywords: alternative health care, complementary treatment, instrument development, nursing practice

Procedia PDF Downloads 367
4933 Exponential Spline Solution for Singularly Perturbed Boundary Value Problems with an Uncertain-But-Bounded Parameter

Authors: Waheed Zahra, Mohamed El-Beltagy, Ashraf El Mhlawy, Reda Elkhadrawy

Abstract:

In this paper, we consider singular perturbation reaction-diffusion boundary value problems, which contain a small uncertain perturbation parameter. To solve these problems, we propose a numerical method which is based on an exponential spline and Shishkin mesh discretization. While interval analysis principle is used to deal with the uncertain parameter, sensitivity analysis has been conducted using different methods. Numerical results are provided to show the applicability and efficiency of our method, which is ε-uniform convergence of almost second order.

Keywords: singular perturbation problem, shishkin mesh, two small parameters, exponential spline, interval analysis, sensitivity analysis

Procedia PDF Downloads 246
4932 Effect of Correlation of Random Variables on Structural Reliability Index

Authors: Agnieszka Dudzik

Abstract:

The problem of correlation between random variables in the structural reliability analysis has been extensively discussed in literature on the subject. The cases taken under consideration were usually related to correlation between random variables from one side of ultimate limit state: correlation between particular loads applied on structure or correlation between resistance of particular members of a structure as a system. It has been proved that positive correlation between these random variables reduces the reliability of structure and increases the probability of failure. In the paper, the problem of correlation between random variables from both side of the limit state equation will be taken under consideration. The simplest case where these random variables are of the normal distributions will be concerned. The case when a degree of that correlation is described by the covariance or the coefficient of correlation will be used. Special attention will be paid on questions: how much that correlation changes the reliability level and can it be ignored. In reliability analysis will be used well-known methods for assessment of the failure probability: based on the Hasofer-Lind reliability index and Monte Carlo method adapted to the problem of correlation. The main purpose of this work will be a presentation how correlation of random variables influence on reliability index of steel bar structures. Structural design parameters will be defined as deterministic values and random variables. The latter will be correlated. The criterion of structural failure will be expressed by limit functions related to the ultimate and serviceability limit state. In the description of random variables will be used only for the normal distribution. Sensitivity of reliability index to the random variables will be defined. If the reliability index sensitivity due to the random variable X will be low when compared with other variables, it can be stated that the impact of this variable on failure probability is small. Therefore, in successive computations, it can be treated as a deterministic parameter. Sensitivity analysis leads to simplify the description of the mathematical model, determine the new limit functions and values of the Hasofer-Lind reliability index. In the examples, the NUMPRESS software will be used in the reliability analysis.

Keywords: correlation of random variables, reliability index, sensitivity of reliability index, steel structure

Procedia PDF Downloads 206
4931 On the Exergy Analysis of the Aluminum Smelter

Authors: Ayoola T. Brimmo, Mohamed I. Hassan

Abstract:

The push to mitigate the aluminum smelting industry’s enormous energy consumption and high emission releases is now even more persistent with the recent climate change happenings. Common approaches to achieve this have been focused on improving energy efficiency in the pot line and cast house sections of the smelter. However, the conventional energy efficiency analyses are based on the first law of thermodynamics, which do not shed proper light on the smelter’s degradation of energy. This just gives a general idea of the furnace’s performance with no reference to locations where improvement is a possibility based on the second law of thermodynamics. In this study, we apply exergy analyses on the pot line and cast house sections of the smelter to identify the locality and causes of energy degradation. The exergy analyses, which are based on a real life smelter conditions, highlight the possible locations for technology improvement in a typical smelter. With this established, methods of minimizing the smelter’s exergy losses are assessed.

Keywords: exergy analysis, electrolytic cell, furnace, heat transfer

Procedia PDF Downloads 258
4930 A Quick Method for Seismic Vulnerability Evaluation of Offshore Structures by Static and Dynamic Nonlinear Analyses

Authors: Somayyeh Karimiyan

Abstract:

To evaluate the seismic vulnerability of vital offshore structures with the highest possible precision, Nonlinear Time History Analyses (NLTHA), is the most reliable method. However, since it is very time-consuming, a quick procedure is greatly desired. This paper presents a quick method by combining the Push Over Analysis (POA) and the NLTHA. The POA is preformed first to recognize the more critical members, and then the NLTHA is performed to evaluate more precisely the critical members’ vulnerability. The proposed method has been applied to jacket type structure. Results show that combining POA and NLTHA is a reliable seismic evaluation method, and also that none of the earthquake characteristics alone, can be a dominant factor in vulnerability evaluation.

Keywords: jacket structure, seismic evaluation, push-over and nonlinear time history analyses, critical members

Procedia PDF Downloads 260
4929 Evaluation of the Accuracy of a ‘Two Question Screening Tool’ in the Detection of Intimate Partner Violence in a Primary Healthcare Setting in South Africa

Authors: A. Saimen, E. Armstrong, C. Manitshana

Abstract:

Intimate partner violence (IPV) has been recognised as a global human rights violation. It is universally under diagnosed and the institution of timeous multi-faceted interventions has been noted to benefit IPV victims. Currently, the concept of using a screening tool to detect IPV has not been widely explored in a primary healthcare setting in South Africa, and it was for this reason that this study has been undertaken. A systematic random sampling of 1 in 8 women over a period of 3 months was conducted prospectively at the OPD of a Level 1 Hospital. Participants were asked about their experience of IPV during the past 12 months. The WAST-short, a two-question tool, was used to screen patients for IPV. To verify the result of the screening, women were also asked the remaining questions from the WAST. Data was collected from 400 participants, with a response rate of 99.3%. The prevalence of IPV in the sample was 32%. The WAST-short was shown to have the following operating characteristics: sensitivity 45.2%, specificity 98%,positive predictive value 98%, negative predictive value 79%. The WAST-short lacks sufficient sensitivity and therefore is not an ideal screening tool for this setting. Improvement in the sensitivity of the WAST-short in this setting may be achieved by lowering the threshold for a positive result for IPV screening, and modification of the screening questions to better reflect IPV as understood by the local population.

Keywords: domestic violence, intimate partner violence, screening, screening tools

Procedia PDF Downloads 279
4928 Diffusion Magnetic Resonance Imaging and Magnetic Resonance Spectroscopy in Detecting Malignancy in Maxillofacial Lesions

Authors: Mohamed Khalifa Zayet, Salma Belal Eiid, Mushira Mohamed Dahaba

Abstract:

Introduction: Malignant tumors may not be easily detected by traditional radiographic techniques especially in an anatomically complex area like maxillofacial region. At the same time, the advent of biological functional MRI was a significant footstep in the diagnostic imaging field. Objective: The purpose of this study was to define the malignant metabolic profile of maxillofacial lesions using diffusion MRI and magnetic resonance spectroscopy, as adjunctive aids for diagnosing of such lesions. Subjects and Methods: Twenty-one patients with twenty-two lesions were enrolled in this study. Both morphological and functional MRI scans were performed, where T1, T2 weighted images, diffusion-weighted MRI with four apparent diffusion coefficient (ADC) maps were constructed for analysis, and magnetic resonance spectroscopy with qualitative and semi-quantitative analyses of choline and lactate peaks were applied. Then, all patients underwent incisional or excisional biopsies within two weeks from MR scans. Results: Statistical analysis revealed that not all the parameters had the same diagnostic performance, where lactate had the highest areas under the curve (AUC) of 0.9 and choline was the lowest with insignificant diagnostic value. The best cut-off value suggested for lactate was 0.125, where any lesion above this value is supposed to be malignant with 90 % sensitivity and 83.3 % specificity. Despite that ADC maps had comparable AUCs still, the statistical measure that had the final say was the interpretation of likelihood ratio. As expected, lactate again showed the best combination of positive and negative likelihood ratios, whereas for the maps, ADC map with 500 and 1000 b-values showed the best realistic combination of likelihood ratios, however, with lower sensitivity and specificity than lactate. Conclusion: Diffusion weighted imaging and magnetic resonance spectroscopy are state-of-art in the diagnostic arena and they manifested themselves as key players in the differentiation process of orofacial tumors. The complete biological profile of malignancy can be decoded as low ADC values, high choline and/or high lactate, whereas that of benign entities can be translated as high ADC values, low choline and no lactate.

Keywords: diffusion magnetic resonance imaging, magnetic resonance spectroscopy, malignant tumors, maxillofacial

Procedia PDF Downloads 147
4927 Computational Analyses of Persian Walnut Genetic Data: Notes on Genetic Diversity and Cultivar Phylogeny

Authors: Masoud Sheidaei, Melica Tabasi, Fahimeh Koohdar, Mona Sheidaei

Abstract:

Juglans regia L. is an economically important species of edible nuts. Iran is known as a center of origin of genetically rich walnut germplasm and expected to be found a large diversity within Iranian walnut populations. A detailed population genetic of local populations is useful for developing an optimal strategy for in situ conservation and can assist the breeders in crop improvement programs. Different phylogenetic studies have been carried out in this genus, but none has been concerned with genetic changes associated with geographical divergence and the identification of adaptive SNPs. Therefore, we carried out the present study to identify discriminating ITS nucleotides among Juglans species and also reveal association between ITS SNPs and geographical variables. We used different computations approaches like DAPC, CCA, and RDA analyses for the above-mentioned tasks. We also performed population genetics analyses for population effective size changes associated with the species expansion. The results obtained suggest that latitudinal distribution has a more profound effect on the species genetic changes. Similarly, multiple analytical approaches utilized for the identification of both discriminating DNA nucleotides/ SNPs almost produced congruent results. The SNPs with different phylogenetic importance were also identified by using a parsimony approach.

Keywords: Persian walnut, adaptive SNPs, data analyses, genetic diversity

Procedia PDF Downloads 96
4926 A Theoretical Modelling and Simulation of a Surface Plasmon Resonance Biosensor for the Detection of Glucose Concentration in Blood and Urine

Authors: Natasha Mandal, Rakesh Singh Moirangthem

Abstract:

The present work reports a theoretical model to develop a plasmonic biosensor for the detection of glucose concentrations in human blood and urine as the abnormality of glucose label is the major cause of diabetes which becomes a life-threatening disease worldwide. This study is based on the surface plasmon resonance (SPR) sensor applications which is a well-established, highly sensitive, label-free, rapid optical sensing tool. Here we have introduced a sandwich assay of two dielectric spacer layers of MgF2 and BaTiO3which gives better performance compared to commonly used SiO2 and TiO2 dielectric spacers due to their low dielectric loss and higher refractive index. The sensitivity of our proposed sensor was found as 3242 nm/RIU approximately, with an excellent linear response of 0.958, which is higher than the conventional single-layer Au SPR sensor. Further, the sensitivity enhancement is also optimized by coating a few layers of two-dimensional (2D) nanomaterials (e.g., Graphene, h-BN, MXene, MoS2, WS2, etc.) on the sensor chip. Hence, our proposed SPR sensor has the potential for the detection of glucose concentration in blood and urine with enhanced sensitivity and high affinity and could be utilized as a reliable platform for the optical biosensing application in the field of medical diagnosis.

Keywords: biosensor, surface plasmon resonance, dielectric spacer, 2D nanomaterials

Procedia PDF Downloads 69
4925 Biopsy or Biomarkers: Which Is the Sample of Choice in Assessment of Liver Fibrosis?

Authors: S. H. Atef, N. H. Mahmoud, S. Abdrahman, A. Fattoh

Abstract:

Background: The aim of the study is to assess the diagnostic value of fibrotest and hyaluronic acid in discriminate between insignificant and significant fibrosis. Also, to find out if these parameters could replace liver biopsy which is currently used for selection of chronic hepatitis C patients eligible for antiviral therapy. Study design: This study was conducted on 52 patients with HCV RNA detected by polymerase chain reaction (PCR) who had undergone liver biopsy and attending the internal medicine clinic at Ain Shams University Hospital. Liver fibrosis was evaluated according to the METAVIR scoring system on a scale of F0 to F4. Biochemical markers assessed were: alpha-2 macroglobulin (α2-MG), apolipoprotein A1 (Apo-A1), haptoglobin, gamma-glutamyl transferase (GGT), total bilirubin (TB) and hyaluronic acid (HA). The fibrotest score was computed after adjusting for age and gender. Predictive values and ROC curves were used to assess the accuracy of fibrotest and HA results. Results: For fibrotest, the observed area under curve for the discrimination between minimal or no fibrosis (F0-F1) and significant fibrosis (F2-F4) was 0.6736 for cutoff value 0.19 with sensitivity of 84.2% and specificity of 85.7%. For HA, the sensitivity was 89.5% and specificity was 85.7% and area under curve was 0.540 at the best cutoff value 71 mg/dL. Multi-use of both parameters, HA at 71 mg/dL with fibrotest score at 0.22 give a sensitivity 89.5%, specificity 100 and efficacy 92.3% (AUC 0.895). Conclusion: The use of both fibrotest score and HA could be as alternative to biopsy in most patients with chronic hepaitis C putting in consideration some limitations of the proposed markers in evaluating liver fibrosis.

Keywords: fibrotest, liver fibrosis, HCV RNA, biochemical markers

Procedia PDF Downloads 262
4924 Effect of Removing Hub Domain on Human CaMKII Isoforms Sensitivity to Calcium/Calmodulin

Authors: Ravid Inbar

Abstract:

CaMKII (calcium-calmodulin dependent protein kinase II) makes up 2% of the protein in our brain and has a critical role in memory formation and long-term potentiation of neurons. Despite this, research has yet to uncover the role of one of the domains on the activation of this kinase. The following proposes to express the protein without the hub domain in E. coli, leaving only the kinase and regulatory segment of the protein. Next, a series of kinase assays will be conducted to elucidate the role the hub domain plays on CaMKII sensitivity to calcium/calmodulin activation. The hub domain may be important for activation; however, it may also be a variety of domains working together to influence protein activation and not the hub alone. Characterization of a protein is critical to the future understanding of the protein's function, as well as for producing pharmacological targets in cases of patients with diseases.

Keywords: CaMKII, hub domain, kinase assays, kinase + reg seg

Procedia PDF Downloads 56
4923 Fatigue Analysis of Spread Mooring Line

Authors: Chanhoe Kang, Changhyun Lee, Seock-Hee Jun, Yeong-Tae Oh

Abstract:

Offshore floating structure under the various environmental conditions maintains a fixed position by mooring system. Environmental conditions, vessel motions and mooring loads are applied to mooring lines as the dynamic tension. Because global responses of mooring system in deep water are specified as wave frequency and low frequency response, they should be calculated from the time-domain analysis due to non-linear dynamic characteristics. To take into account all mooring loads, environmental conditions, added mass and damping terms at each time step, a lot of computation time and capacities are required. Thus, under the premise that reliable fatigue damage could be derived through reasonable analysis method, it is necessary to reduce the analysis cases through the sensitivity studies and appropriate assumptions. In this paper, effects in fatigue are studied for spread mooring system connected with oil FPSO which is positioned in deep water of West Africa offshore. The target FPSO with two Mbbls storage has 16 spread mooring lines (4 bundles x 4 lines). The various sensitivity studies are performed for environmental loads, type of responses, vessel offsets, mooring position, loading conditions and riser behavior. Each parameter applied to the sensitivity studies is investigated from the effects of fatigue damage through fatigue analysis. Based on the sensitivity studies, the following results are presented: Wave loads are more dominant in terms of fatigue than other environment conditions. Wave frequency response causes the higher fatigue damage than low frequency response. The larger vessel offset increases the mean tension and so it results in the increased fatigue damage. The external line of each bundle shows the highest fatigue damage by the governed vessel pitch motion due to swell wave conditions. Among three kinds of loading conditions, ballast condition has the highest fatigue damage due to higher tension. The riser damping occurred by riser behavior tends to reduce the fatigue damage. The various analysis results obtained from these sensitivity studies can be used for a simplified fatigue analysis of spread mooring line as the reference.

Keywords: mooring system, fatigue analysis, time domain, non-linear dynamic characteristics

Procedia PDF Downloads 312