Search results for: length of shadows
2507 Computational Fluid Dynamic Modelling of the Desander: A Case Study from Pakistan
Authors: Ali Heidari, Hosain Ardalan
Abstract:
A CFD model was developed for a desander on the waterway of the Madyan Hydro Power Plant (MHPP), which is under construction in northeast Pakistan. An underground desander was designed to settle the sediments before the headrace tunnel, which is 14 km long. The desander chamber consists of 2 caverns, each including 2 basins with flushing-type desander, adopted in the feasibility design on the left bank of the river. A 3D flow simulation was developed to interpret the desander performance according to flow velocity. Then, a particle-based model was developed to check the sediment particle sizes in different areas of the desander. 11 Scenarios were defined for different configurations of the desander, including the transition vertical slope, symmetric and asymmetric entrance, the basin net length, and tranquilizer racks specifications. The model's runtime using a medium-class supper computer was several days for each scenario because of the required time interval for the defined pixel size of the 3D model. It also needed to extend the duration time of the modeling to the travel time of sediment particles along the desander. The results of the 3D models for different entrance transition slopes showed that a high slope transition zone is not acceptable due to the turbulence/vortex at the transition. The sediment drainage channel was extended to the transition with an expanding side slope upstream to have a better trapping performance for bigger particles. The desander configuration and the net length were modeled in different scenarios to reach the design particle size removal criteria of 0.2 and 0.3 mm. The results show that the desander design configuration in the feasibility stage with a net length of 204 meters and transition angle of 34° is an overdesign configuration. On the other hand, reducing the desander net length to less than 135 meters does not fulfill the design criterion of 0.2 mm particle size removal. The Scenarios included asymmetric and symmetric entrance transition zone configurations for the four basins. The CFD results confirmed the symmetric desander configuration, with a net length of 135 m and a transition angle of 34° to the horizon, as the optimum configuration. The configuration provides a removal efficiency of 97% for a particle size of 0.2 mm. The CFD results also show that horizontal tranquilizing racks are risky and do not help sediment trapping in the basin. However, the horizontally inclined tranquilizer decreases the turbulence by transferring the flow energy into the main basin. Nonetheless, more evaluation is needed to optimize the transition zone length by using a tranquilizer at the entrance and evaluating the tranquilizer racks with vertical alignments by building a convenient physical model.Keywords: CFD, sediment, desander, madyan
Procedia PDF Downloads 52506 Comparison of Agree Method and Shortest Path Method for Determining the Flow Direction in Basin Morphometric Analysis: Case Study of Lower Tapi Basin, Western India
Authors: Jaypalsinh Parmar, Pintu Nakrani, Bhaumik Shah
Abstract:
Digital Elevation Model (DEM) is elevation data of the virtual grid on the ground. DEM can be used in application in GIS such as hydrological modelling, flood forecasting, morphometrical analysis and surveying etc.. For morphometrical analysis the stream flow network plays a very important role. DEM lacks accuracy and cannot match field data as it should for accurate results of morphometrical analysis. The present study focuses on comparing the Agree method and the conventional Shortest path method for finding out morphometric parameters in the flat region of the Lower Tapi Basin which is located in the western India. For the present study, open source SRTM (Shuttle Radar Topography Mission with 1 arc resolution) and toposheets issued by Survey of India (SOI) were used to determine the morphometric linear aspect such as stream order, number of stream, stream length, bifurcation ratio, mean stream length, mean bifurcation ratio, stream length ratio, length of overland flow, constant of channel maintenance and aerial aspect such as drainage density, stream frequency, drainage texture, form factor, circularity ratio, elongation ratio, shape factor and relief aspect such as relief ratio, gradient ratio and basin relief for 53 catchments of Lower Tapi Basin. Stream network was digitized from the available toposheets. Agree DEM was created by using the SRTM and stream network from the toposheets. The results obtained were used to demonstrate a comparison between the two methods in the flat areas.Keywords: agree method, morphometric analysis, lower Tapi basin, shortest path method
Procedia PDF Downloads 2402505 Passive Control of Elliptic Jet by Using Triangular and Truncated Tabs
Authors: Saif Akram, E. Rathakrishnan
Abstract:
The mixing promoting efficiency of two identical sharp and truncated vertex triangular tabs offering geometrical blockage of 2.5% each, placed at the exit of a Mach 1.5 elliptic nozzle was studied experimentally. The effectiveness of both the tabs in enhancing the mixing of jets with the ambient air are determined by measuring the Pitot pressure along the jet axis and the jet spread in both the minor and major axes of the elliptic nozzle, covering marginally overexpanded to moderately underexpanded levels at the nozzle exit. The results reveal that both the tabs enhance mixing characteristics of the uncontrolled elliptic jet when placed at minor axis. A core length reduction of 67% is achieved at NPR 3 which is the overexpanded state. Similarly, the core length is reduced by about 67%, 50% and 57% at NPRs of 4, 5 and 6 (underexpanded states) respectively. However, unlike the considerable increment in mixing promoting efficiency by the use of truncated vertex tabs for axisymmetric jets, the effect is not much pronounced for the case of supersonic elliptic jets. The CPD plots for both the cases almost overlap, especially when tabs are placed at minor axis, at all the pressure conditions. While, when the tabs are used at major axis, in the case of overexpanded condition, the sharp vertex triangular tabs act as a better mixing enhancer for the supersonic elliptic jets. For the jet controlled with truncated vertex triangular tabs, the core length reductions are of the same order as those for the sharp vertex triangular tabs. The jet mixing is hardly influenced by the tip effect in case of supersonic elliptic jet.Keywords: elliptic jet, tabs, truncated, triangular
Procedia PDF Downloads 3882504 Effects of Length of Time of Fasting upon Subjective and Objective Variables When Controlling Sleep, Food and Fluid Intakes
Authors: H. Alabed, K. Abuzayan. L. Fgie, K. Zarug
Abstract:
Ramadan requires individuals to abstain from food and fluid intake between sunrise and sunset; physiological considerations predict that poorer mood, physical performance and mental performance will result. In addition, any difficulties will be worsened because preparations for fasting and recovery from it often mean that nocturnal sleep is decreased in length, and this independently affects mood and performance. A difficulty of interpretation in many studies is that the observed changes could be due to fasting but also to the decreased length of sleep and altered food and fluid intakes before and after the daytime fasting. These factors were separated in this study, which took place over three separate days and compared the effects of different durations of fasting (4, 8 or 16h) upon a wide variety of measures (including subjective and objective assessments of performance, body composition, dehydration and responses to a short bout of exercise) - but with an unchanged amount of nocturnal sleep, controlled supper the previous evening, controlled intakes at breakfast and daytime naps not being allowed. Many of the negative effects of fasting observed in previous studies were present in this experiment also. These findings indicate that fasting was responsible for many of the changes previously observed, though some effect of sleep loss, particularly if occurring on successive days (as would occur in Ramadan) cannot be excluded.Keywords: drinking, eating, mental performance, physical performance, social activity, blood, sleepiness
Procedia PDF Downloads 4012503 Oscillatory Electroosmotic Flow in a Microchannel with Slippage at the Walls and Asymmetric Wall Zeta Potentials
Authors: Oscar Bautista, Jose Arcos
Abstract:
In this work, we conduct a theoretical analysis of an oscillatory electroosmotic flow in a parallel-plate microchannel taking into account slippage at the microchannel walls. The governing equations given by the Poisson-Boltzmann (with the Debye-Huckel approximation) and momentum equations are nondimensionalized from which four dimensionless parameters appear; a Reynolds angular number, the ratio between the zeta potentials of the microchannel walls, the electrokinetic parameter and the dimensionless slip length which measures the competition between the Navier slip length and the half height microchannel. The principal results indicate that the slippage has a strong influence on the magnitude of the oscillatory electroosmotic flow increasing the velocity magnitude up to 50% for the numerical values used in this work.Keywords: electroosmotic flows, oscillatory flow, slippage, microchannel
Procedia PDF Downloads 2262502 Effect of Passive Pectoralis Minor Stretching on Scapular Kinematics in Scapular Dyskinesia
Authors: Seema Saini, Nidhi Chandra, Tushar Palekar
Abstract:
Objective: To determine the effect of Passive pectoralis minor muscle stretching on scapular kinematics in individuals with scapular dyskinesia. Design: A randomized controlled study was conducted in Pune. The sample size was 30 subjects, which were randomly allocated to either Group A, the experimental group in which passive pectoralis minor stretch was given, or Group B, the control group, in which conventional exercises were given for 3 days a week over 4 weeks. Pre and Post treatment readings of the outcome measures, pectoralis minor length, scapular upward rotation, and lateral scapular slide test were recorded. Results: The results obtained prove a significant difference between pre and post mean values of pectoralis minor length in group A (pre 21.91, post 22.87) and in group B (pre 23.55 post 23.99); scapular upward rotation in group A (pre 49.95, post 50.61) and group B (pre 52.64, post 53.51); lateral scapular slide test at 0° abduction in group A (pre 6.613, post 6.14) and group B (pre 6.84, post 6.22); lateral scapular slide test at 45° abduction in group A (pre 7.14 and post 7.12) and group B (pre 8.18, post 7.53). With an inter-group analysis, it was found that mean of pectoralis minor length, scapular upward rotation, and LSST at 0° abduction in group A was significant than group B (p<0.05). Conclusion: Passive pectoralis minor stretching along with conventional strengthening exercises was shown to be more effective in improving scapular kinematics among patients with scapular dyskinesia.Keywords: scapulohumeral rhythm, scapular upward rotation, rounded shoulders, scapular strengthening
Procedia PDF Downloads 1652501 Effects of Length of Time of Fasting Upon Subjective and Objective Variables When Prior Sleep and Food and Fluid Intakes Have Been Controlled
Authors: H. Alabed, K. Abuzayan, J. Ezarrugh, S. Ali, M. Touba
Abstract:
Ramadan requires individuals to abstain from food and fluid intake between sunrise and sunset, Physiological considerations predict that poorer mood, Physical performance and mental performance will result. In addition, Any difficulties will be worsened because preparations for fasting and recovery from it often mean that nocturnal sleep is decreased in length and this independently affects mood and performance. A difficulty of interpretation in many studies is that the observed changes could be due to fasting but also to the decreased length of sleep and altered food and fluid intakes before and after the daytime fasting. These factors were separated in this study, Which took place over three separate days and compared the effects of different durations of fasting (4, 8 or 16 h) upon a wide variety of measures (including subjective and objective assessments of performance, body composition, Dehydration and responses to a short bout of exercise) but with an unchanged amount of nocturnal sleep, Controlled supper the previous evening, Controlled intakes at breakfast and daytime naps not being allowed. Many of the negative effects of fasting observed in previous studies were present in this experiment also. These findings indicate that fasting was responsible for many of the changes previously observed, Though some effect of sleep loss, Particularly if occurring on successive days (as would occur in Ramadan) cannot be excluded.Keywords: Drinking, eating, mental performance, physical performance, social activity, blood, sleepiness
Procedia PDF Downloads 3202500 Exploring Factors Influencing Orthopedic Patients' Willingness to Recommend a Hospital: Insights from a Cross-Sectional Survey
Authors: Merav Ben Natan, David Maman, Milana Avramov, Galina Shamilov, Yaron Berkovich
Abstract:
Introduction: Patient satisfaction and the willingness to recommend a hospital are vital for improving healthcare quality. This study examines orthopedic patients to identify factors influencing their willingness to recommend the hospital. Aim: This study to explore the demographic and clinical variables affecting orthopedic patients' willingness to recommend the hospital and to understand the role of patient satisfaction in this context. Methods: A cross-sectional survey was conducted with 200 orthopedic patients hospitalized between July and December 2023 in north-central Israel. Data were analyzed to assess the impact of various factors on the willingness to recommend the hospital. Results: Age was positively associated with the willingness to recommend (OR=2.44), while the length of stay in the Emergency Department negatively impacted this willingness (OR=0.58). Satisfaction with hospital care had a positive effect on willingness to recommend (OR=1.96). Gender, comorbidities, and total hospital stay length did not significantly influence willingness to recommend. Conclusions: Satisfaction with hospital care and the length of Emergency Department stays are crucial factors affecting orthopedic patients' willingness to recommend the hospital. This underscores the need for strategies to improve patient experiences and address delays in the Emergency Department. The findings offer valuable insights for healthcare providers and policymakers.Keywords: orthopedic patients, patient satisfaction, willingness to recommend, hospital recommendation
Procedia PDF Downloads 392499 Heat Exchanger Optimization of a Domestic Refrigerator with Separate Cooling Circuits
Authors: Tugba Tosun, Mert Tosun
Abstract:
Cooling system performance and energy consumption in the bypass two-circuit cycle have been studied experimentally to find optimum evaporator type and geometry, capillary tube diameter and capillary length. Two types of evaporators, such as wire on the tube and finned tube evaporators were used for the experiments in the fresh food compartment. As capillary tube inner diameter and total length; 0.66 mm and 0.8mm, and 3000 mm and 3500 mm were selected as parameters, respectively. Experiments were performed at the 25⁰C ambient temperature while the average temperature of the fresh food compartment is kept at 5⁰C and the highest package temperature of the freezer compartment is kept at -18⁰C, which are defined in IEC 62552 European standard. The Design of Experiments (DOE) technique which is six sigma method has been used to indicate of effective parameters in the bypass two-circuit cycle. The experimental results revealed that the most effective parameter of the system is the evaporator type. Finned tube evaporator with 12 tube passes was found as the best option for the bypass two-circuit refrigeration cycle among the 8 different opportunities. The optimum cooling performance and the lowest energy consumption were provided with 0.66 mm capillary tube inner diameter and 3500 mm capillary tube length.Keywords: capillary tube, energy consumption, heat exchanger, refrigerator, separate cooling circuits
Procedia PDF Downloads 1752498 Optimization of Slider Crank Mechanism Using Design of Experiments and Multi-Linear Regression
Authors: Galal Elkobrosy, Amr M. Abdelrazek, Bassuny M. Elsouhily, Mohamed E. Khidr
Abstract:
Crank shaft length, connecting rod length, crank angle, engine rpm, cylinder bore, mass of piston and compression ratio are the inputs that can control the performance of the slider crank mechanism and then its efficiency. Several combinations of these seven inputs are used and compared. The throughput engine torque predicted by the simulation is analyzed through two different regression models, with and without interaction terms, developed according to multi-linear regression using LU decomposition to solve system of algebraic equations. These models are validated. A regression model in seven inputs including their interaction terms lowered the polynomial degree from 3rd degree to 1st degree and suggested valid predictions and stable explanations.Keywords: design of experiments, regression analysis, SI engine, statistical modeling
Procedia PDF Downloads 1892497 Buckling of Plates on Foundation with Different Types of Sides Support
Authors: Ali N. Suri, Ahmad A. Al-Makhlufi
Abstract:
In this paper the problem of buckling of plates on foundation of finite length and with different side support is studied. The Finite Strip Method is used as tool for the analysis. This method uses finite strip elastic, foundation, and geometric matrices to build the assembly matrices for the whole structure, then after introducing boundary conditions at supports, the resulting reduced matrices is transformed into a standard Eigenvalue-Eigenvector problem. The solution of this problem will enable the determination of the buckling load, the associated buckling modes and the buckling wave length. To carry out the buckling analysis starting from the elastic, foundation, and geometric stiffness matrices for each strip a computer program FORTRAN list is developed. Since stiffness matrices are function of wave length of buckling, the computer program used an iteration procedure to find the critical buckling stress for each value of foundation modulus and for each boundary condition. The results showed the use of elastic medium to support plates subject to axial load increase a great deal the buckling load, the results found are very close with those obtained by other analytical methods and experimental work. The results also showed that foundation compensates the effect of the weakness of some types of constraint of side support and maximum benefit found for plate with one side simply supported the other free.Keywords: buckling, finite strip, different sides support, plates on foundation
Procedia PDF Downloads 2452496 Multi-Path Signal Synchronization Model with Phase Length Constraints
Authors: Tzu-Jung Huang, Hsun-Jung Cho, Chien-Chia Liäm Huang
Abstract:
To improve the level of service (LoS) of urban arterial systems containing a series of signalized intersections, a proper design of offsets for all intersections associated is of great importance. The MAXBAND model has been the most common approach for this purpose. In this paper, we propose a MAXBAND model with phase constraints so that the lengths of the phases in a cycle are variable. In other words, the length of a cycle is also variable in our setting. We conduct experiments on a real-world traffic network, having several major paths, in Taiwan for numerical evaluations. Actual traffic data were collected through on-site experiments. Numerical evidences suggest that the improvements are around 32%, on average, in terms of total delay of the entire network.Keywords: arterial progression, MAXBAND, signal control, offset
Procedia PDF Downloads 3642495 Nuclear Characteristics of a Heterogeneous Thorium-Based Fuel Design Aimed at Increasing Fuel Cycle Length of a Typical PWR
Authors: Hendrik Bernard Van Der Walt, Frik Van Niekerk
Abstract:
Heterogeneous thorium-based fuels have been proposed as an alternative for conventional reactor fuels and many studies have shown promising results. Fuel cycle characteristics still have to be explored in detail. This study investigates the use of a novel thorium-based fuel design aimed at increasing fuel cycle length of a typical PWR with an explicit focus on thorium- uranium content, neutron spectrum, flux considerations and neutron economy.As nuclear reactions are highly dependent on reactor flux and material matrix, analytical and numerical calculations have been completed to predict the behaviour of the proposed nuclear fuel. The proposed design utilizes various ratios of thorium oxide and uranium oxide pellets within fuel pins, divided into heterogeneous sections of specified length. This design renders multiple regions with unique characteristics. The goal of this study is to determine and optimally utilize these characteristics. Proliferation considerations result in the need for denaturing of heterogeneous regions, which renders more unique characteristics, these aspects were examined in this study. Finally, the use of fertile thorium to emulate a burnable poison for managing excess BOL reactivity has been investigated, as well as an option for flux shaping in a typical PWR.Keywords: nuclear fuel, nuclear characteristics, nuclear fuel cycle, thorium-based fuel, heterogeneous design
Procedia PDF Downloads 1412494 Numerical Study of Piled Raft Foundation Under Vertical Static and Seismic Loads
Authors: Hamid Oumer Seid
Abstract:
Piled raft foundation (PRF) is a union of pile and raft working together through the interaction of soil-pile, pile-raft, soil-raft and pile-pile to provide adequate bearing capacity and controlled settlement. A uniform pile positioning is used in PRF; however, there is a wide room for optimization through parametric study under vertical load to result in a safer and economical foundation. Addis Ababa is found in seismic zone 3 with a peak ground acceleration (PGA) above the threshold of damage, which makes investigating the performance of PRF under seismic load considering the dynamic kinematic soil structure interaction (SSI) vital. The study area is located in Addis Ababa around Mexico (commercial bank) and Kirkos (Nib, Zemen and United Bank) in which input parameters (pile length, pile diameter, pile spacing, raft area, raft thickness and load) are taken. A finite difference-based numerical software, FLAC3D V6, was used for the analysis. The Kobe (1995) and Northridge (1994) earthquakes were selected, and deconvolution analysis was done. A close load sharing between pile and raft was achieved at a spacing of 7D with different pile lengths and diameters. The maximum settlement reduction achieved is 9% for a pile of 2m diameter by increasing length from 10m to 20m, which shows pile length is not effective in reducing settlement. The installation of piles results in an increase in the negative bending moment of the raft compared with an unpiled raft. Hence, the optimized design depends on pile spacing and the raft edge length, while pile length and diameter are not significant parameters. An optimized piled raft configuration (𝐴𝐺/𝐴𝑅 = 0.25 at the center and piles provided around the edge) has reduced pile number by 40% and differential settlement by 95%. The dynamic analysis shows acceleration plot at the top of the piled raft has PGA of 0.25𝑚2/𝑠𝑒𝑐 and 0.63𝑚2/𝑠𝑒𝑐 for Northridge (1994) and Kobe (1995) earthquakes, respectively, due to attenuation of seismic waves. Pile head displacement (maximum is 2mm, and it is under the allowable limit) is affected by the PGA rather than the duration of an earthquake. End bearing and friction PRF performed similarly under two different earthquakes except for their vertical settlement considering SSI. Hence, PRF has shown adequate resistance to seismic loads.Keywords: FLAC3D V6, earthquake, optimized piled raft foundation, pile head department
Procedia PDF Downloads 352493 Estimation of Consolidating Settlement Based on a Time-Dependent Skin Friction Model Considering Column Surface Roughness
Authors: Jiang Zhenbo, Ishikura Ryohei, Yasufuku Noriyuki
Abstract:
Improvement of soft clay deposits by the combination of surface stabilization and floating type cement-treated columns is one of the most popular techniques worldwide. On the basis of one dimensional consolidation model, a time-dependent skin friction model for the column-soil interaction is proposed. The nonlinear relationship between column shaft shear stresses and effective vertical pressure of the surrounding soil can be described in this model. The influence of column-soil surface roughness can be represented using a roughness coefficient R, which plays an important role in the design of column length. Based on the homogenization method, a part of floating type improved ground will be treated as an unimproved portion, which with a length of αH1 is defined as a time-dependent equivalent skin friction length. The compression settlement of this unimproved portion can be predicted only using the soft clay parameters. Apart from calculating the settlement of this composited ground, the load transfer mechanism is discussed utilizing model tests. The proposed model is validated by comparing with calculations and laboratory results of model and ring shear tests, which indicate the suitability and accuracy of the solutions in this paper.Keywords: floating type improved foundation, time-dependent skin friction, roughness, consolidation
Procedia PDF Downloads 4722492 Approximate Spring Balancing for Swimming Pool Lift Mechanism to Reduce Actuator Torque
Authors: Apurva Patil, Sujatha Srinivasan
Abstract:
Reducing actuator loads is important for applications in which human effort is required for actuation. The potential benefit of applying spring balancing to rehabilitation devices which work against gravity on a nonhorizontal plane is well recognized, but practical applications have been elusive. Although existing methods provide exact spring balance, they require additional masses or auxiliary links, or all the springs used originate from the ground, which makes the resulting device bulky and space-inefficient. This paper uses a method of static balancing of mechanisms with conservative loads such as gravity and spring loads using non-zero-free-length springs and no auxiliary links. Application of this method to a manually operated swimming pool lift mechanism which lowers and raises the physically challenged users into or out of the swimming pool is presented here. Various possible configurations using extension and compression springs as well as gas spring in the mechanism are compared. This work involves approximate spring balancing of the mechanism using minimization of potential energy variance. It uses the approach of flattening the potential energy distribution over the workspace and fuses it with numerical optimization. The results show the considerable reduction in actuator torque requirement with practical spring design and arrangement. Although the method provides only an approximate balancing, it is versatile, flexible in choosing appropriate control variables that are relevant to the design problem and easy to implement. The true potential of this technique lies in the fact that it uses a very simple optimization to find the spring constant, free length of the spring and the optimal attachment points subject to the optimization constraints. Also, it uses physically realizable non-zero-free-length springs directly, thereby reducing the complexity involved in simulating zero-free-length springs from non-zero-free-length springs. This method allows springs to be attached inside the mechanism, which makes the implementation of spring balancing practical. Because auxiliary linkages can be avoided, the resultant swimming pool lift mechanism is compact. The cost benefits and reduced complexity can be significant advantages in the development of this user-actuated swimming pool lift for developing countries.Keywords: gas spring, rehabilitation device, spring balancing, swimming pool lift
Procedia PDF Downloads 2452491 Phonological Encoding and Working Memory in Kannada Speaking Adults Who Stutter
Authors: Nirmal Sugathan, Santosh Maruthy
Abstract:
Background: A considerable number of studies have evidenced that phonological encoding (PE) and working memory (WM) skills operate differently in adults who stutter (AWS). In order to tap these skills, several paradigms have been employed such as phonological priming, phoneme monitoring, and nonword repetition tasks. This study, however, utilizes a word jumble paradigm to assess both PE and WM using different modalities and this may give a better understanding of phonological processing deficits in AWS. Aim: The present study investigated PE and WM abilities in conjunction with lexical access in AWS using jumbled words. The study also aimed at investigating the effect of increase in cognitive load on phonological processing in AWS by comparing the speech reaction time (SRT) and accuracy scores across various syllable lengths. Method: Participants were 11 AWS (Age range=19-26) and 11 adults who do not stutter (AWNS) (Age range=19-26) matched for age, gender and handedness. Stimuli: Ninety 3-, 4-, and 5-syllable jumbled words (JWs) (n=30 per syllable length category) constructed from Kannada words served as stimuli for jumbled word paradigm. In order to generate jumbled words (JWs), the syllables in the real words were randomly transpositioned. Procedures: To assess PE, the JWs were presently visually using DMDX software and for WM task, JWs were presented through auditory mode through headphones. The participants were asked to silently manipulate the jumbled words to form a Kannada real word and verbally respond once. The responses for both tasks were audio recorded using record function in DMDX software and the recorded responses were analyzed using PRAAT software to calculate the SRT. Results: SRT: Mann-Whitney test results demonstrated that AWS performed significantly slower on both tasks (p < 0.001) as indicated by increased SRT. Also, AWS presented with increased SRT on both the tasks in all syllable length conditions (p < 0.001). Effect of syllable length: Wilcoxon signed rank test was carried out revealed that, on task assessing PE, the SRT of 4syllable JWs were significantly higher in both AWS (Z= -2.93, p=.003) and AWNS (Z= -2.41, p=.003) when compared to 3-syllable words. However, the findings for 4- and 5-syllable words were not significant. Task Accuracy: The accuracy scores were calculated for three syllable length conditions for both PE and PM tasks and were compared across the groups using Mann-Whitney test. The results indicated that the accuracy scores of AWS were significantly below that of AWNS in all the three syllable conditions for both the tasks (p < 0.001). Conclusion: The above findings suggest that PE and WM skills are compromised in AWS as indicated by increased SRT. Also, AWS were progressively less accurate in descrambling JWs of increasing syllable length and this may be interpreted as, rather than existing as a uniform deficiency, PE and WM deficits emerge when the cognitive load is increased. AWNS exhibited increased SRT and increased accuracy for JWs of longer syllable length whereas AWS was not benefited from increasing the reaction time, thus AWS had to compromise for both SRT and accuracy while solving JWs of longer syllable length.Keywords: adults who stutter, phonological ability, working memory, encoding, jumbled words
Procedia PDF Downloads 2462490 Biometry and Pathology of Internal Genital Organs of Female Camel (Camelus dromedarius) in Lahore, Pakistan
Authors: Umair Riaz, Mudassar Iqbal, Umer Farooq, Farah Ali, Musadiq Idris
Abstract:
The present work was designed to establish biometrical norms for ovaries, oviducts and crevices of one humped camels (Camelus dromedarius) and the diseases associated thereof in various age groups viz. calves (< 2 years, n=15), heifers (2-4 years, n=34) and adults (> 4 years, n=81). The genitalia were attained from Lahore Abbatoir, Punjab, Pakistan. Ovaries, oviducts and cervices of experimental genitalia were assessed for their length, width, thickness and weight. Statistically, there was no difference in the length and width of both left and right ovaries which however, increased with the advancement of age of camel. Similar results were noticed regarding the width of oviducts. The mean length of cervices of female camels correlated well with the number of cervical annular rings amongst the age groups. Regarding the abnormalities of ovaries and cervices in the 3 age groups, camel calves did not have any of the abnormalities. However, ovarian hypoplasia in heifers (2.94%) and follicular cyst in adult female camels (1.23%) were revealed in the present study. Mucocervix in heifers (2.96%) and cervicitis 1.23% in adult camels was also noticed. The present work presents a preliminary data on biometrical analysis for one humped camels and envisages a broader study with increased population and sample size.Keywords: camelus dromedarius, pathology, biometry, female genital tract
Procedia PDF Downloads 5962489 Various Body Measurements of Hair, Boer x Hair F1 Crossbred Kids and Effects of Some Environmental Factors on These Traits
Authors: M. Bolacalı, Y. Öztürk, O. Yılmaz, M. Küçük, M. A. Karslı
Abstract:
The aim of the study was to determine various body measurements from the birth to the 30-day age of Boer x Hair goats F1 crossbred kids and pure Hair goat kids raised in Van in Eastern Anatolia region, and reveal factors such as the effects of year, dame body weight, genotype, dame age, birth type and sex on this parameter. 49 kids born in 2012 and 76 kids born in 2014 were utilized in the study. In the statistical analysis of various body measurements data was performed using the General Lineer Model procedure in SPSS software. Duncan's multiple range test was used for multiple comparisons. Boer x Hair goats F1 crossbred kids and pure Hair goat kids from various body measurements cidago height, body length, chest length, chest depth, chest circumference, circumference of leg, cannon bone circumference, chest width were determinated in general respectively 29.90 and 27.88 cm; 29.49 and 27.93 cm; 17.28 and 16.68 cm; 13.34 and 12.82 cm; 31.74 and 29.85 cm; 28.43 and 23.95 cm; 5.41 and 5.15 cm; 8.71 and 7.63 cm at birth, respectively; 35.01 and 32.98 cm; 35.20 and 33.30 cm; 18.82 and 18.17 cm; 15.64 and 14.83 cm; 39.08 and 37.30 cm; 34.29 and 29.25 cm; 5.80 and 5.42 cm; 9.87 and 8.85 cm at 30 days age, respectively. Among factors affecting cidago height in this study, the effect of dame body weight and sex were not significant, but genotype, dame age and birth type were significant (P < 0,05 and P < 0,01) at birth; dame body weight effect of the cidago height was not significant, but the effect of genotype, birth type, of dame age and sex were significant (P < 0.05, P < 0.05 and P<0.001) at 30-day age. The effect of genotype and sex of body length were not significant, but dam age, dame body weight and birth type were significant (P < 0.05, P < 0.05 and P<0.001, respectively) at birth; the effect of sex to body length was not significant, but genotype, dame age, dame body weight and birth type were significant (P < 0.01, P < 0.05, P < 0.05 and P < 0.001, respectively) at 30-day age. While circumference of leg was insignificant the effect of dame age and sex, genotype, dame body weight and type of the birth were significant (P < 0.001, P < 0.05 and P < 0.001) at birth; the circumstance of leg at 30-day age was found to be important the effect of examined other factors except for sex (P < 0.05 and P < 0.001). The obtained results, when considered in terms of a variety of body sizes, from birth to 30-day age growth period, showed that the kids of Boer x Hair Goat F1 hybrids have higher values than the kids of Hair Goats.Keywords: Boer x hair goat F1 crossbred, hair goat, body measurements, cidago height
Procedia PDF Downloads 3532488 Establishment of Diagnostic Reference Levels for Computed Tomography Examination at the University of Ghana Medical Centre
Authors: Shirazu Issahaku, Isaac Kwesi Acquah, Simon Mensah Amoh, George Nunoo
Abstract:
Introduction: Diagnostic Reference Levels are important indicators for monitoring and optimizing protocol and procedure in medical imaging between facilities and equipment. This helps to evaluate whether, in routine clinical conditions, the median value obtained for a representative group of patients within an agreed range from a specified procedure is unusually high or low for that procedure. This study aimed to propose Diagnostic Reference Levels for Computed Tomography examination of the most common routine examination of the head, chest and abdominal pelvis regions at the University of Ghana Medical Centre. Methods: The Diagnostic Reference Levels were determined based on the investigation of the most common routine examinations, including head Computed Tomography examination with and without contrast, abdominopelvic Computed Tomography examination with and without contrast, and chest Computed Tomography examination without contrast. The study was based on two dose indicators: the volumetric Computed Tomography Dose Index and Dose-Length Product. Results: The estimated median distribution for head Computed Tomography with contrast for volumetric-Computed Tomography dose index and Dose-Length Product were 38.33 mGy and 829.35 mGy.cm, while without contrast, were 38.90 mGy and 860.90 mGy.cm respectively. For an abdominopelvic Computed Tomography examination with contrast, the estimated volumetric-Computed Tomography dose index and Dose-Length Product values were 40.19 mGy and 2096.60 mGy.cm. In the absence of contrast, the calculated values were 14.65 mGy and 800.40 mGy.cm, respectively. Additionally, for chest Computed Tomography examination, the estimated values were 12.75 mGy and 423.95 mGy.cm for volumetric-Computed Tomography dose index and Dose-Length Product, respectively. These median values represent the proposed diagnostic reference values of the head, chest, and abdominal pelvis regions. Conclusions: The proposed Diagnostic Reference Level is comparable to the recommended International Atomic Energy Agency and International Commission Radiation Protection Publication 135 and other regional published data by the European Commission and Regional National Diagnostic Reference Level in Africa. These reference levels will serve as benchmarks to guide clinicians in optimizing radiation dose levels while ensuring accurate diagnostic image quality at the facility.Keywords: diagnostic reference levels, computed tomography dose index, computed tomography, radiation exposure, dose-length product, radiation protection
Procedia PDF Downloads 672487 CMOS Solid-State Nanopore DNA System-Level Sequencing Techniques Enhancement
Authors: Syed Islam, Yiyun Huang, Sebastian Magierowski, Ebrahim Ghafar-Zadeh
Abstract:
This paper presents system level CMOS solid-state nanopore techniques enhancement for speedup next generation molecular recording and high throughput channels. This discussion also considers optimum number of base-pair (bp) measurements through channel as an important role to enhance potential read accuracy. Effective power consumption estimation offered suitable rangeof multi-channel configuration. Nanopore bp extraction model in statistical method could contribute higher read accuracy with longer read-length (200 < read-length). Nanopore ionic current switching with Time Multiplexing (TM) based multichannel readout system contributed hardware savings.Keywords: DNA, nanopore, amplifier, ADC, multichannel
Procedia PDF Downloads 4562486 Characteristic Study on Conventional and Soliton Based Transmission System
Authors: Bhupeshwaran Mani, S. Radha, A. Jawahar, A. Sivasubramanian
Abstract:
Here, we study the characteristic feature of conventional (ON-OFF keying) and soliton based transmission system. We consider 20 Gbps transmission system implemented with Conventional Single Mode Fiber (C-SMF) to examine the role of Gaussian pulse which is the characteristic of conventional propagation and hyperbolic-secant pulse which is the characteristic of soliton propagation in it. We note the influence of these pulses with respect to different dispersion lengths and soliton period in conventional and soliton system, respectively, and evaluate the system performance in terms of quality factor. From the analysis, we could prove that the soliton pulse has more consistent performance even for long distance without dispersion compensation than the conventional system as it is robust to dispersion. For the length of transmission of 200 Km, soliton system yielded Q of 33.958 while the conventional system totally exhausted with Q=0.Keywords: dispersion length, retrun-to-zero (rz), soliton, soliton period, q-factor
Procedia PDF Downloads 3482485 Analysis of Evolution of Higher Order Solitons by Numerical Simulation
Authors: K. Khadidja
Abstract:
Solitons are stable solution of nonlinear Schrodinger equation. Their stability is due to the exact combination between nonlinearity and dispersion which causes pulse broadening. Higher order solitons are born when nonlinear length is N multiple of dispersive length. Soliton order is determined by the number N itself. In this paper, evolution of higher order solitons is illustrated by simulation using Matlab. Results show that higher order solitons change their shape periodically, the reason why they are bad for transmission comparing to fundamental solitons which are constant. Partial analysis of a soliton of higher order explains that the periodic shape is due to the interplay between nonlinearity and dispersion which are not equal during a period. This class of solitons has many applications such as generation of supercontinuum and the impulse compression on the Femtosecond scale. As a conclusion, the periodicity which is harmful to transmission can be beneficial in other applications.Keywords: dispersion, nonlinearity, optical fiber, soliton
Procedia PDF Downloads 1722484 Investigation of Length Effect on Power Conversion Efficiency of Perovskite Solar Cells Composed of ZnO Nanowires
Authors: W. S. Li, S. T. Yang, H. C. Cheng
Abstract:
The power conversion efficiency (PCE) of the perovskite solar cells has been achieved by inserting vertically-aligned ZnO nanowires (NWs) between the cathode and the active layer and shows better solar cells performance. Perovskite solar cells have drawn significant attention due to the superb efficiency and low-cost fabrication process. In this experiment, ZnO nanowires are used as the electron transport layer (ETL) due to its low temperature process. The main idea of this thesis is utilizing the 3D structures of the hydrothermally-grown ZnO nanowires to increase the junction area to improve the photovoltaic performance of the perovskite solar cells. The infiltration and the surface coverage of the perovskite precursor solution changed as tuning the length of the ZnO nanowires. It is revealed that the devices with ZnO nanowires of 150 nm demonstrated the best PCE of 8.46 % under the AM 1.5G illumination (100 mW/cm2).Keywords: hydrothermally-grown ZnO nanowires, perovskite solar cells, low temperature process, pinholes
Procedia PDF Downloads 3332483 Role of Preoperative and Postoperative Endovaginal Ultrasound and 24-Hour Pad Test in Evaluation of Efficacy of Various Treatment Modalities for Stress Urinary Incontinence
Authors: J. B. Sharma, Vivek Kakkar, Sunesh Kumar, K. K. Roy, Rajesh Kumari, Kavita Pandey, Smriti Hari
Abstract:
Background: Stress urinary incontinence (SUI) is a common problem affecting the quality of life of women. Methods: It is a prospective study conducted over 40 women of SUI by endovaginal ultrasound on rest and Valsalva preoperatively and six months postoperatively for levator hiatus, pubovisceral thickness, urethral length, and bladder neck position. A 24-hour pad test was also performed on all women at the same time for grading of SUI. Treatment given was medical in 4 (10%), Burch colposuspension in 18 (45%), and tension-free obturator tape in 18 (45%). Results: Mean age, parity, and body mass index in the study were 41.60 years, 2.73, and 24.2 kg/m², respectively. All 40 (100%) patients had SUI, with the mean duration of symptoms being 4.04 years. On the 24-hour pad test, mild SUI was in 4 (10%), moderate SUI in 33 (82.5%), and severe SUI in 3 (7.5%), with mean preoperative 24-hour pad test being 36.69 gm which significantly reduced to 9.79 gm postoperatively (p 0.001). There was a significant change in levator hiatus and pubovisceral thickness with the treatment of SUI. Overall urethral length increased, but there was a significant decrease in urethral length on Valsalva after the treatment (0.40 versus 0.28 cm, p 0.04) and a significant reduction in bladder neck descent after Valsalva after treatment (0.41 cm versus 0.27 cm, p 0.001). Conclusion: Endovaginal ultrasound and 24-hour pad test are useful diagnostic modalities for SUI diagnosis and to see the impact of treatment.Keywords: stress urinary incontinence, endovaginal ultrasound, 24-hours pad test, pubovisceral muscle thickness
Procedia PDF Downloads 982482 Quality Fabric Optimization Using Genetic Algorithms
Authors: Halimi Mohamed Taher, Kordoghli Bassem, Ben Hassen Mohamed, Sakli Faouzi
Abstract:
Textile industry has been an important part of many developing countries economies such as Tunisia. This industry is confronted with a challenging and increasing competitive environment. Good quality management in production process is the key factor for retaining existence especially in raw material exploitation. The present work aims to develop an intelligent system for fabric inspection. In the first step, we have studied the method used for fabric control which takes into account the default length and localization in woven. In the second step, we have used a method based on the fuzzy logic to minimize the Demerit point indicator with appropriate total rollers length, so that the quality problem becomes multi-objective. In order to optimize the total fabric quality, we have applied the genetic algorithm (GA).Keywords: fabric control, Fuzzy logic, genetic algorithm, quality management
Procedia PDF Downloads 5942481 Predicting Dose Level and Length of Time for Radiation Exposure Using Gene Expression
Authors: Chao Sima, Shanaz Ghandhi, Sally A. Amundson, Michael L. Bittner, David J. Brenner
Abstract:
In a large-scale radiologic emergency, potentially affected population need to be triaged efficiently using various biomarkers where personal dosimeters are not likely worn by the individuals. It has long been established that radiation injury can be estimated effectively using panels of genetic biomarkers. Furthermore, the rate of radiation, in addition to dose of radiation, plays a major role in determining biological responses. Therefore, a better and more accurate triage involves estimating both the dose level of the exposure and the length of time of that exposure. To that end, a large in vivo study was carried out on mice with internal emitter caesium-137 (¹³⁷Cs). Four different injection doses of ¹³⁷Cs were used: 157.5 μCi, 191 μCi, 214.5μCi, and 259 μCi. Cohorts of 6~7 mice from the control arm and each of the dose levels were sacrificed, and blood was collected 2, 3, 5, 7 and 14 days after injection for microarray RNA gene expression analysis. Using a generalized linear model with penalized maximum likelihood, a panel of 244 genes was established and both the doses of injection and the number of days after injection were accurately predicted for all 155 subjects using this panel. This has proven that microarray gene expression can be used effectively in radiation biodosimetry in predicting both the dose levels and the length of exposure time, which provides a more holistic view on radiation exposure and helps improving radiation damage assessment and treatment.Keywords: caesium-137, gene expression microarray, multivariate responses prediction, radiation biodosimetry
Procedia PDF Downloads 2012480 Performance Evaluations of Lap Spliced Joint of Decked Bulb-Tee Type Modular Bridge
Authors: Sang-Yoon Lee, Jae-Joon Song
Abstract:
Precast decked bulb-tee girder or precast deck generally adopts in-situ connections of loop joints. Loop joint could be an effective method to connect precast concrete members where the width of joint is not wide sufficiently to allow the lap splice length of reinforcing bars. However, the regulation for the minimum bend diameter of looped rebar gives limitation not to reduce the thickness of precast concrete member; thus, in-situ connection adopting loop joint place a constraint on improving the structural efficiency of precast concrete member. Ultra high strength concrete (UHSC) is effective on reduce the development and lap splice length of reinforcing bar. In-situ connection with UHSC gives a merit to reduce connection width. This study intends to investigate the details of the longitudinal joint to be applied in the precast modular bridge using decked bulb-tee girder that has been recently developed in Korea. This paper presents the details applying UHSC and lap splices of straight reinforcement and results of tests. Several tests were performed on flexural specimens with longitudinal joints to verify the length of the lap splices and amount of transverse reinforcement, and to examine the flexural strength of the longitudinal joint.Keywords: precast structure, decked bulb-tee girder, in-situ connection, UHSC, modular bridge
Procedia PDF Downloads 4642479 Performance Evaluation of a Piano Key Weir
Authors: M. Shaheer Ali, Talib Mansoor
Abstract:
The Piano Key Weir (PKW) is a particular shape of labyrinth weir, using up- and/or downstream overhangs. The horizontal rectangular labyrinth shape allows to multiply the crest length for a given weir width. With the increasing demand of power, it is becoming greatly essential to increase the storage capacity of existing dams without neglecting their safety. The present aims at comparing the performance of piano key weirs in respect to the normal sharp-crested weirs. The discharge v/s head data for the piano key weir and normal sharp-crested weir obtained from the experimental study were compared and analysed using regression analysis. Piano key weir was found to perform doubly w.r.t a normal weir. The flow profiles show the parabolic nature of flow and the nappe interference in the inlet keys.Keywords: crest length, flow profile, labyrinth weir, normal weir, nappe interference, overhangs, piano key weir
Procedia PDF Downloads 2982478 Cotton Fiber Quality Improvement by Introducing Sucrose Synthase (SuS) Gene into Gossypium hirsutum L.
Authors: Ahmad Ali Shahid, Mukhtar Ahmed
Abstract:
The demand for long staple fiber having better strength and length is increasing with the introduction of modern spinning and weaving industry in Pakistan. Work on gene discovery from developing cotton fibers has helped to identify dozens of genes that take part in cotton fiber development and several genes have been characterized for their role in fiber development. Sucrose synthase (SuS) is a key enzyme in the metabolism of sucrose in a plant cell, in cotton fiber it catalyzes a reversible reaction, but preferentially converts sucrose and UDP into fructose and UDP-glucose. UDP-glucose (UDPG) is a nucleotide sugar act as a donor for glucose residue in many glycosylation reactions and is essential for the cytosolic formation of sucrose and involved in the synthesis of cell wall cellulose. The study was focused on successful Agrobacterium-mediated stable transformation of SuS gene in pCAMBIA 1301 into cotton under a CaMV35S promoter. Integration and expression of the gene were confirmed by PCR, GUS assay, and real-time PCR. Young leaves of SuS overexpressing lines showed increased total soluble sugars and plant biomass as compared to non-transgenic control plants. Cellulose contents from fiber were significantly increased. SEM analysis revealed that fibers from transgenic cotton were highly spiral and fiber twist number increased per unit length when compared with control. Morphological data from field plants showed that transgenic plants performed better in field conditions. Incorporation of genes related to cotton fiber length and quality can provide new avenues for fiber improvement. The utilization of this technology would provide an efficient import substitution and sustained production of long-staple fiber in Pakistan to fulfill the industrial requirements.Keywords: agrobacterium-mediated transformation, cotton fiber, sucrose synthase gene, staple length
Procedia PDF Downloads 237