Search results for: Reem Adas
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 67

Search results for: Reem Adas

7 Safety Tolerance Zone for Driver-Vehicle-Environment Interactions under Challenging Conditions

Authors: Matjaž Šraml, Marko Renčelj, Tomaž Tollazzi, Chiara Gruden

Abstract:

Road safety is a worldwide issue with numerous and heterogeneous factors influencing it. On the side, driver state – comprising distraction/inattention, fatigue, drowsiness, extreme emotions, and socio-cultural factors highly affect road safety. On the other side, the vehicle state has an important role in mitigating (or not) the road risk. Finally, the road environment is still one of the main determinants of road safety, defining driving task complexity. At the same time, thanks to technological development, a lot of detailed data is easily available, creating opportunities for the detection of driver state, vehicle characteristics and road conditions and, consequently, for the design of ad hoc interventions aimed at improving driver performance, increase awareness and mitigate road risks. This is the challenge faced by the i-DREAMS project. i-DREAMS, which stands for a smart Driver and Road Environment Assessment and Monitoring System, is a 3-year project funded by the European Union’s Horizon 2020 research and innovation program. It aims to set up a platform to define, develop, test and validate a ‘Safety Tolerance Zone’ to prevent drivers from getting too close to the boundaries of unsafe operation by mitigating risks in real-time and after the trip. After the definition and development of the Safety Tolerance Zone concept and the concretization of the same in an Advanced driver-assistance system (ADAS) platform, the system was tested firstly for 2 months in a driving simulator environment in 5 different countries. After that, naturalistic driving studies started for a 10-month period (comprising a 1-month pilot study, 3-month baseline study and 6 months study implementing interventions). Currently, the project team has approved a common evaluation approach, and it is developing the assessment of the usage and outcomes of the i-DREAMS system, which is turning positive insights. The i-DREAMS consortium consists of 13 partners, 7 engineering universities and research groups, 4 industry partners and 2 partners (European Transport Safety Council - ETSC - and POLIS cities and regions for transport innovation) closely linked to transport safety stakeholders, covering 8 different countries altogether.

Keywords: advanced driver assistant systems, driving simulator, safety tolerance zone, traffic safety

Procedia PDF Downloads 45
6 Corneal Confocal Microscopy As a Surrogate Marker of Neuronal Pathology In Schizophrenia

Authors: Peter W. Woodruff, Georgios Ponirakis, Reem Ibrahim, Amani Ahmed, Hoda Gad, Ioannis N. Petropoulos, Adnan Khan, Ahmed Elsotouhy, Surjith Vattoth, Mahmoud K. M. Alshawwaf, Mohamed Adil Shah Khoodoruth, Marwan Ramadan, Anjushri Bhagat, James Currie, Ziyad Mahfoud, Hanadi Al Hamad, Ahmed Own, Peter Haddad, Majid Alabdulla, Rayaz A. Malik

Abstract:

Introduction:- We aimed to test the hypothesis that, using corneal confocal microscopy (a non-invasive method for assessing corneal nerve fibre integrity), patients with schizophrenia would show neuronal abnormalities compared with healthy participants. Schizophrenia is a neurodevelopmental and progressive neurodegenerative disease, for which there are no validated biomarkers. Corneal confocal microscopy (CCM) is a non-invasive ophthalmic imaging biomarker that can be used to detect neuronal abnormalities in neuropsychiatric syndromes. Methods:- Patients with schizophrenia (DSM-V criteria) without other causes of peripheral neuropathy and healthy controls underwent CCM, vibration perception threshold (VPT) and sudomotor function testing. The diagnostic accuracy of CCM in distinguishing patients from controls was assessed using the area under the curve (AUC) of the Receiver Operating Characterstics (ROC) curve. Findings:- Participants with schizophrenia (n=17) and controls (n=38) with comparable age (35.7±8.5 vs 35.6±12.2, P=0.96) were recruited. Patients with schizophrenia had significantly higher body weight (93.9±25.5 vs 77.1±10.1, P=0.02), lower Low Density Lipoproteins (2.6±1.0 vs 3.4±0.7, P=0.02), but comparable systolic and diastolic blood pressure, HbA1c, total cholesterol, triglycerides and High Density Lipoproteins were comparable with control participants. Patients with schizophrenia had significantly lower corneal nerve fiber density (CNFD, fibers/mm2) (23.5±7.8 vs 35.6±6.5, p<0.0001), branch density (CNBD, branches/mm2) (34.4±26.9 vs 98.1±30.6, p<0.0001), and fiber length (CNFL, mm/mm2) (14.3±4.7 vs 24.2±3.9, p<0.0001) but no difference in VPT (6.1±3.1 vs 4.5±2.8, p=0.12) and electrochemical skin conductance (61.0±24.0 vs 68.9±12.3, p=0.23) compared with controls. The diagnostic accuracy of CNFD, CNBD and CNFL to distinguish patients with schizophrenia from healthy controls were, according to the AUC, (95% CI): 87.0% (76.8-98.2), 93.2% (84.2-102.3), 93.2% (84.4-102.1), respectively. Conclusion:- In conclusion, CCM can be used to help identify neuronal changes and has a high diagnostic accuracy to distinguish subjects with schizophrenia from healthy controls.

Keywords:

Procedia PDF Downloads 253
5 Validation of the Arabic Version of the Positive and Negative Syndrome Scale (PANSS)

Authors: Arij Yehya, Suhaila Ghuloum, Abdlmoneim Abdulhakam, Azza Al-Mujalli, Mark Opler, Samer Hammoudeh, Yahya Hani, Sundus Mari, Reem Elsherbiny, Ziyad Mahfoud, Hassen Al-Amin

Abstract:

Introduction: The Positive and Negative Syndrome Scale (PANSS) is a valid instrument developed by Kay and colleagues6 to assess symptoms of patients with schizophrenia. It consists of 30 items that factor the symptoms into three subscales: positive, negative and general psychopathology. This scale has been translated and validated in several languages. Objective: This study aims to determine the validity and psychometric properties of the Arabic version of the PANSS. Methods: A standardized translation and cultural adaptation method was adopted. Patients diagnosed with schizophrenia (n=98), according to psychiatrist’s diagnosis based on DSM-IV criteria, were recruited from the Psychiatry Department at Rumailah Hospital, Qatar. A first rater confirmed the diagnosis using the Arabic version of Mini International Neuropsychiatric Interview (MINI 6). A second and independent rater-administered the Arabic version of PANSS. Also, a control group (n=101), with no history of psychiatric disorder was recruited from the family and friends of the patients and from primary health care centers in Qatar. Results: There were more males than females in our sample of patients with schizophrenia (68.9% and 31.6%, respectively). On the other hand, in the control group the number of females outweighed that of males (58.4% and 41.6% respectively). The scale had a good internal consistency with Cronbach’s alpha 0.91. There was a significant difference between the scores on the three subscales of the PANSS. Patients with schizophrenia scored significantly higher (p<.0001) than the control subjects on subscales for positive symptoms 20.01(SD=7.21) and 7.30(SD=1.38), negative symptoms 18.89(SD=8.88) and 7.37(SD=2.38) and general psychopathology 34.41 (SD=11.56) and 16.93 (SD=3.93), respectively. Factor analysis and ROC curve were carried out to further test the psychometrics of the scale. Conclusions: The Arabic version of PANSS is a reliable and valid tool to assess both positive and negative symptoms of patients with schizophrenia in a balanced manner. In addition to providing the Arab population with a standardized tool to monitor symptoms of schizophrenia, this version provides a gateway to compare the prevalence of positive and negative symptoms in the Arab world which can be compared to others done elsewhere.

Keywords: Arabic version, assessment, diagnosis, schizophrenia, validation

Procedia PDF Downloads 615
4 Projected Impact of Population Aging on Noncommunicable Disease Burden and Costs in the Kingdom of Saudi Arabia, 2020–2030

Authors: David C. Boettiger, Tracy Kuo Lin, Maram Almansour, Mariam M. Hamza, Reem Alsukait, Christopher H. Herbst, Nada Altheyab, Ayman Afghani, Faisal Kattan

Abstract:

Background The number of people aged greater than 65 years per 100 people aged 20–64 years is expected to almost double in The Kingdom of Saudi Arabia (KSA) between 2020 and 2030. We therefore aimed to quantify the growing non-communicable disease (NCD) burden in KSA between 2020 and 2030, and the impact this will have on the national health budget. Methods Ten priority NCDs were selected: ischemic heart disease, stroke, type 2 diabetes, chronic obstructive pulmonary disease, chronic kidney disease, dementia, depression, osteoarthritis, colorectal cancer, and breast cancer. Age- and sex-specific prevalence was projected for each priority NCD between 2020 and 2030. Treatment coverage rates were applied to the projected prevalence estimates to calculate the number of patients incurring treatment costs for each condition. For each priority NCD, the average cost-of-illness was estimated based on published literature. The impact of changes to our base-case model in terms of assumed disease prevalence, treatment coverage, and costs of care, coming into effect from 2023 onwards, were explored. Results The prevalence estimates for colorectal cancer and stroke were estimated to almost double between 2020 and 2030 (97% and 88% increase, respectively). The only priority NCD prevalence projected to increase by less than 60% between 2020 and 2030 was for depression (22% increase). It is estimated that the total cost of managing priority NCDs in KSA will increase from USD 19.8 billion in 2020 to USD 32.4 billion in 2030 (an increase of USD 12.6 billion or 63%). The largest USD value increases were projected for osteoarthritis (USD 4.3 billion), diabetes (USD 2.4 billion), and dementia (USD 1.9 billion). In scenario analyses, our 2030 projection for the total cost of managing priority NCDs varied between USD 29.2 billion - USD 35.7 billion. Conclusions Managing the growing NCD burden in KSA’s aging population will require substantial healthcare spending increases over the coming years.

Keywords: aging, non communicable disease, costs, Saudi Arabia

Procedia PDF Downloads 25
3 Effective Use of X-Box Kinect in Rehabilitation Centers of Riyadh

Authors: Reem Alshiha, Tanzila Saba

Abstract:

Physical rehabilitation is the process of helping people to recover and be able to go back to their former activities that have been delayed due to external factors such as car accidents, old age and victims of strokes (chronic diseases and accidents, and those related to sport activities).The cost of hiring a personal nurse or driving the patient to and from the hospital could be costly and time-consuming. Also, there are other factors to take into account such as forgetfulness, boredom and lack of motivation. In order to solve this dilemma, some experts came up with rehabilitation software to be used with Microsoft Kinect to help the patients and their families for in-home rehabilitation. In home rehabilitation software is becoming more and more popular, since it is more convenient for all parties affiliated with the patient. In contrast to the other costly market-based systems that have no portability, Microsoft’s Kinect is a portable motion sensor that reads body movements and interprets it. New software development has made rehabilitation games available to be used at home for the convenience of the patient. The game will benefit its users (rehabilitation patients) in saving time and money. There are many software's that are used with the Kinect for rehabilitation, but the software that is chosen in this research is Kinectotherapy. Kinectotherapy software is used for rehabilitation patients in Riyadh clinics to test its acceptance by patients and their physicians. In this study, we used Kinect because it was affordable, portable and easy to access in contrast to expensive market-based motion sensors. This paper explores the importance of in-home rehabilitation by using Kinect with Kinectotherapy software. The software targets both upper and lower limbs, but in this research, the main focus is on upper-limb functionality. However, the in-home rehabilitation is applicable to be used by all patients with motor disability, since the patient must have some self-reliance. The targeted subjects are patients with minor motor impairment that are somewhat independent in their mobility. The presented work is the first to consider the implementation of in-home rehabilitation with real-time feedback to the patient and physician. This research proposes the implementation of in-home rehabilitation in Riyadh, Saudi Arabia. The findings show that most of the patients are interested and motivated in using the in-home rehabilitation system in the future. The main value of the software application is due to these factors: improve patient engagement through stimulating rehabilitation, be a low cost rehabilitation tool and reduce the need for expensive one-to-one clinical contact. Rehabilitation is a crucial treatment that can improve the quality of life and confidence of the patient as well as their self-esteem.

Keywords: x-box, rehabilitation, physical therapy, rehabilitation software, kinect

Procedia PDF Downloads 322
2 Correlation Between Different Radiological Findings and Histopathological diagnosis of Breast Diseases: Retrospective Review Conducted Over Sixth Years in King Fahad University Hospital in Eastern Province, Saudi Arabia

Authors: Sadeem Aljamaan, Reem Hariri, Rahaf Alghamdi, Batool Alotaibi, Batool Alsenan, Lama Althunayyan, Areej Alnemer

Abstract:

The aim of this study is to correlate between radiological findings and histopathological results in regard to the breast imaging-reporting and data system scores, size of breast masses, molecular subtypes and suspicious radiological features, as well as to assess the concordance rate in histological grade between core biopsy and surgical excision among breast cancer patients, followed by analyzing the change of concordance rate in relation to neoadjuvant chemotherapy in a Saudi population. A retrospective review was conducted over 6-year period (2017-2022) on all breast core biopsies of women preceded by radiological investigation. Chi-squared test (χ2) was performed on qualitative data, the Mann-Whitney test for quantitative non-parametric variables, and the Kappa test for grade agreement. A total of 641 cases were included. Ultrasound, mammography, and magnetic resonance imaging demonstrated diagnostic accuracies of 85%, 77.9% and 86.9%; respectively. magnetic resonance imaging manifested the highest sensitivity (72.2%), and the lowest was for ultrasound (61%). Concordance in tumor size with final excisions was best in magnetic resonance imaging, while mammography demonstrated a higher tendency of overestimation (41.9%), and ultrasound showed the highest underestimation (67.7%). The association between basal-like molecular subtypes and the breast imaging-reporting and data system score 5 classifications was statistically significant only for magnetic resonance imaging (p=0.04). Luminal subtypes demonstrated a significantly higher percentage of speculation in mammography. Breast imaging-reporting and data system score 4 manifested a substantial number of benign pathologies in all the 3 modalities. A fair concordance rate (k= 0.212 & 0.379) was demonstrated between excision and the preceding core biopsy grading with and without neoadjuvant therapy, respectively. The results demonstrated a down-grading in cases post-neoadjuvant therapy. In cases who did not receive neoadjuvant therapy, underestimation of tumor grade in biopsy was evident. In summary, magnetic resonance imaging had the highest sensitivity, specificity, positive predictive value and accuracy of both diagnosis and estimation of tumor size. Mammography demonstrated better sensitivity than ultrasound and had the highest negative predictive value, but ultrasound had better specificity, positive predictive value and accuracy. Therefore, the combination of different modalities is advantageous. The concordance rate of core biopsy grading with excision was not impacted by neoadjuvant therapy.

Keywords: breast cancer, mammography, MRI, neoadjuvant, pathology, US

Procedia PDF Downloads 65
1 Molecular Identification of Camel Tick and Investigation of Its Natural Infection by Rickettsia and Borrelia in Saudi Arabia

Authors: Reem Alajmi, Hind Al Harbi, Tahany Ayaad, Zainab Al Musawi

Abstract:

Hard ticks Hyalomma spp. (family: Ixodidae) are obligate ectoparasite in their all life stages on some domestic animals mainly camels and cattle. Ticks may lead to many economic and public health problems because of their blood feeding behavior. Also, they act as vectors for many bacterial, viral and protozoan agents which may cause serious diseases such as tick-born encephalitis, Rocky-mountain spotted fever, Q-fever and Lyme disease which can affect human and/or animals. In the present study, molecular identification of ticks that attack camels in Riyadh region, Saudi Arabia based on the partial sequence of mitochondrial 16s rRNA gene was applied. Also, the present study aims to detect natural infections of collected camel ticks with Rickessia spp. and Borelia spp. using PCR/hybridization of Citrate synthase encoding gene present in bacterial cells. Hard ticks infesting camels were collected from different camels located in a farm in Riyadh region, Saudi Arabia. Results of the present study showed that the collected specimens belong to two species: Hyalomma dromedari represent 99% of the identified specimens and Hyalomma marginatum which account for 1 % of identified ticks. The molecular identification was made through blasting the obtained sequence of this study with sequences already present and identified in GeneBank. All obtained sequences of H. dromedarii specimens showed 97-100% identity with the same gene sequence of the same species (Accession # L34306.1) which was used as a reference. Meanwhile, no intraspecific variations of H. marginatum mesured because only one specimen was collected. Results also had shown that the intraspecific variability between individuals of H. dromedarii obtained in 92 % of samples ranging from 0.2- 6.6%, while the remaining 7 % of the total samples of H. dromedarii showed about 10.3 % individual differences. However, the interspecific variability between H. dromedarii and H. marginatum was approximately 18.3 %. On the other hand, by using the technique of PCR/hybridization, we could detect natural infection of camel ticks with Rickettsia spp. and Borrelia spp. Results revealed the natural presence of both bacteria in collected ticks. Rickettsial spp. infection present in 29% of collected ticks, while 35% of collected specimen were infected with Borrelia spp. The valuable results obtained from the present study are a new record for the molecular identification of camel ticks in Riyadh, Saudi Arabia and their natural infection with both Rickettsia spp. and Borrelia spp. These results may help scientists to provide a good and direct control strategy of ticks in order to protect one of the most important economic animals which are camels. Also results of this project spotlight on the disease that might be transmitted by ticks to put out a direct protective plan to prevent spreading of these dangerous agents. Further molecular studies are needed to confirm the results of the present study by using other mitochondrial and nuclear genes for tick identification.

Keywords: Camel ticks, Rickessia spp. , Borelia spp. , mitochondrial 16s rRNA gene

Procedia PDF Downloads 254