Search results for: laboratory test
11005 Moderating Effects of Future Career Interest in Science and Gender on Students' Achievement in Basic Science in Oyo State, Nigeria
Authors: Segun Jacob Ogunkunle
Abstract:
The study examined the moderating effects of future career interest in science and gender on achievement in basic science of students taught in a simulated laboratory and enriched laboratory guide material environments. It adopted the pretest-posttest control group quasi experimental design with a 3x2x2 factorial matrix. A total of 277 (130 males, 147 females; ± 17 years) junior secondary three students randomly selected from six purposively selected secondary schools based on availability of functional computer and physics laboratories participated in the study. Data were collected using achievement test in basic science (r=0.87) and future career interest in science (r=0.99) while analysis of covariance and estimated marginal means were used to test three hypotheses at 0.05 level of significance. The findings of the study show that future career interest in science had significant effect on students’ achievement in basic science whereas gender did not. The interaction effect of future career interest in science and gender on students’ achievement in basic science was not significant. It is therefore recommended that prior knowledge of students’ future career interest in science could be used to improve participation in basic science practical in order to enhance achievement in biology, chemistry, and physics at the post-basic education level in Nigeria.Keywords: future career interest in science, basic science, simulated laboratory, enriched laboratory guide materials, achievement in science
Procedia PDF Downloads 16111004 Mechanical Qualification Test Campaign on the Demise Observation Capsule
Authors: B. Tiseo, V. Quaranta, G. Bruno, R. Gardi, T. Watts, S. Dussy
Abstract:
This paper describes the qualification test campaign performed on the Demise Observation Capsule DOC-EQM as part of the Future Launch Preparatory Program FLPP3. The mechanical environment experienced during launch ascent and separation phase was first identified and then replicated in terms of sine, random and shock vibration. The loads identification is derived by selecting the worst possible case. Vibration and shock qualification test performed at CIRA Space Qualification laboratory is herein described. Mechanical fixtures’ design and validation, carried out by means of FEM, is also addressed due to its fundamental role in the vibrational test campaign. The Demise Observation Capsule (DOC) successfully passed the qualification test campaign. Functional test and resonance search have not been point any fault and damages of the capsule.Keywords: capsule, demise, demise observation capsule, DOC, launch environment, re-ntry, qualification
Procedia PDF Downloads 15311003 The Benefits of Security Culture for Improving Physical Protection Systems at Detection and Radiation Measurement Laboratory
Authors: Ari S. Prabowo, Nia Febriyanti, Haryono B. Santosa
Abstract:
Security function that is called as Physical Protection Systems (PPS) has functions to detect, delay and response. Physical Protection Systems (PPS) in Detection and Radiation Measurement Laboratory needs to be improved continually by using internal resources. The nuclear security culture provides some potentials to support this research. The study starts by identifying the security function’s weaknesses and its strengths of security culture as a purpose. Secondly, the strengths of security culture are implemented in the laboratory management. Finally, a simulation was done to measure its effectiveness. Some changes were happened in laboratory personnel behaviors and procedures. All became more prudent. The results showed a good influence of nuclear security culture in laboratory security functions.Keywords: laboratory, physical protection system, security culture, security function
Procedia PDF Downloads 19211002 Laboratory Evaluation of Geogrids Used for Stabilizing Soft Subgrades
Authors: Magdi M. E. Zumrawi, Nehla Mansour
Abstract:
This paper aims to assess the efficiency of using geogrid reinforcement for subgrade stabilization. The literature of applying geogrid reinforcement technique for pavements built on soft subgrades and the previous experiences were reviewed. Laboratory tests were conducted on soil reinforced with geogrids in one or several layers. The soil specimens were compacted in four layers with or without geogrid sheets. The California Bearing Ratio (CBR) test, in soaking condition, was performed on natural soil and soil-geogrid specimens. The test results revealed that the CBR value is much affected by the geogrid sheet location and the number of sheets used in the soil specimen. When a geogrid sheet was placed at the 1st layer of the soil, there was an increment of 26% in the CBR value. Moreover, the CBR value was significantly increased by 62% when geogrid sheets were placed at all four layers. The high CBR value is attributed to interface friction and interlock involved in the geogrid/ soil interactions. It could be concluded that geogrid reinforcement is successful and more economical technique.Keywords: geogrid, reinforcement, stabilization, subgrade
Procedia PDF Downloads 32411001 Evaluation of Liquefaction Potential of Fine Grained Soil: Kerman Case Study
Authors: Reza Ziaie Moayed, Maedeh Akhavan Tavakkoli
Abstract:
This research aims to investigate and evaluate the liquefaction potential in a project in Kerman city based on different methods for fine-grained soils. Examining the previous damages caused by recent earthquakes, it has been observed that fine-grained soils play an essential role in the level of damage caused by soil liquefaction. But, based on previous investigations related to liquefaction, there is limited attention to evaluating the cyclic resistance ratio for fine-grain soils, especially with the SPT method. Although using a standard penetration test (SPT) to find the liquefaction potential of fine-grain soil is not common, it can be a helpful method based on its rapidness, serviceability, and availability. In the present study, the liquefaction potential has been first determined by the soil’s physical properties obtained from laboratory tests. Then, using the SPT test and its available criterion for evaluating the cyclic resistance ratio and safety factor of liquefaction, the correction of effecting fine-grained soils is made, and then the results are compared. The results show that using the SPT test for liquefaction is more accurate than using laboratory tests in most cases due to the contribution of different physical parameters of soil, which leads to an increase in the ultimate N₁(60,cs).Keywords: liquefaction, cyclic resistance ratio, SPT test, clay soil, cohesion soils
Procedia PDF Downloads 10311000 Correlation between the Undrained Shear Strength of Clay of the Champlain Sea as Determined by the Vane Test and the Swedish Cone
Authors: Tahar Ayadat
Abstract:
The undrained shear strength is an essential parameter for determining the consistency and the ultimate bearing capacity of a clay layer. The undrained shear strength can be determined by field tests such as the in situ vane test or in laboratory, including hand vane test, triaxial, simple compression test, and the consistency penetrometer (i.e. Swedish cone). However, the field vane test and the Swedish cone are the most commonly used tests by geotechnical experts. In this technical note, a comparison between the shear strength results obtained by the in situ vane test and the cone penetration test (Swedish cone) was conducted. A correlation between the results of these two tests, concerning the undrained shear strength of the Champlain sea clay, has been developed. Moreover, some applications of the proposed correlation on some geotechnical problems have been included, such as the determination of the consistency and the bearing capacity of a clay layer.Keywords: correlation, shear strength, clay, vane test, Swedish cone
Procedia PDF Downloads 39610999 In Online and Laboratory We Trust: Comparing Trust Game Behavior in Three Environments
Authors: Kaisa M. Herne, Hanna E. Björkstedt
Abstract:
Comparisons of online and laboratory environments are important for assessing whether the environment influences behavioral results. Trust game behavior was examined in three environments: 1) The standard laboratory setting with physically present participants (laboratory), 2) An online environment with an online meeting before playing the trust game (online plus a meeting); and 3) An online environment without a meeting (online without a meeting). In laboratory, participants were present in a classroom and played the trust game anonymously via computers. Online plus a meeting mimicked the laboratory in that participants could see each other in an online meeting before sessions started, whereas online without a meeting was a standard online experiment in which participants did not see each other at any stages of the experiment. Participants were recruited through pools of student subjects at two universities. The trust game was identical in all conditions; it was played with the same software, anonymously, and with stranger matching. There were no statistically significant differences between the treatment conditions regarding trust or trustworthiness. Results suggest that conducting trust game experiments online will yield similar results to experiments implemented in a laboratory.Keywords: laboratory vs. online experiment, trust behavior, trust game, trustworthiness behavior
Procedia PDF Downloads 8210998 Verification of Space System Dynamics Using the MATLAB Identification Toolbox in Space Qualification Test
Authors: Yuri V. Kim
Abstract:
This article presents a new approach to the Functional Testing of Space Systems (SS). It can be considered as a generic test and used for a wide class of SS that from the point of view of System Dynamics and Control may be described by the ordinary differential equations. Suggested methodology is based on using semi-natural experiment- laboratory stand that doesn’t require complicated, precise and expensive technological control-verification equipment. However, it allows for testing system as a whole totally assembled unit during Assembling, Integration and Testing (AIT) activities, involving system hardware (HW) and software (SW). The test physically activates system input (sensors) and output (actuators) and requires recording their outputs in real time. The data is then inserted in laboratory PC where it is post-experiment processed by Matlab/Simulink Identification Toolbox. It allows for estimating system dynamics in form of estimation of system differential equations by the experimental way and comparing them with expected mathematical model prematurely verified by mathematical simulation during the design process.Keywords: system dynamics, space system ground tests and space qualification, system dynamics identification, satellite attitude control, assembling, integration and testing
Procedia PDF Downloads 16510997 Effect of Open-Ended Laboratory toward Learners Performance in Environmental Engineering Course: Case Study of Civil Engineering at Universiti Malaysia Sabah
Authors: N. Bolong, J. Makinda, I. Saad
Abstract:
Laboratory activities have produced benefits in student learning. With current drives of new technology resources and evolving era of education methods, renewal status of learning and teaching in laboratory methods are in progress, for both learners and the educators. To enhance learning outcomes in laboratory works particularly in engineering practices and testing, learning via hands-on by instruction may not sufficient. This paper describes and compares techniques and implementation of traditional (expository) with open-ended laboratory (problem-based) for two consecutive cohorts studying environmental laboratory course in civil engineering program. The transition of traditional to problem-based findings and effect were investigated in terms of course assessment student feedback survey, course outcome learning measurement and student performance grades. It was proved that students have demonstrated better performance in their grades and 12% increase in the course outcome (CO) in problem-based open-ended laboratory style than traditional method; although in perception, students has responded less favorable in their feedback.Keywords: engineering education, open-ended laboratory, environmental engineering lab
Procedia PDF Downloads 31910996 Memory Consolidation: Application of Retrieval Strategies in the Classroom
Authors: Eric Tardif, Nicolas Meylan
Abstract:
Recent studies suggest that the consolidation of episodic memory is better achieved through repeated retrieval than with the use of concept mapping or repeated study. Although such laboratory results highly appeal to educationalists, it remains to be shown whether they can be directly used in a classroom setting. Forty-five college students (42 girls; mean age 16.1 y/o) were asked to remember pairs of biology-related words (e.g. mitochondria-energy) in two configurations. The first configuration consisted of a three-minute study of pairs of words followed by a final one-minute test in which the first word of a pair was shown and the subject asked to write down the second associated word. This procedure was repeated three times. The second configuration consisted of a one-minute study of a list of pairs of words, which was immediately followed by a one-minute test. This procedure was repeated 6 times. Subjects filled out a small questionnaire assessing their general mood, level of fatigue, stress and motivation to do the exercise. One week later, subjects were given a final test using the same words. A total of 8 lists of words were studied and tested during the semester. Results showed that subjects recalled more correct words when using the second configuration, both within the study period and one week later, confirming laboratory findings. However, the general performance (mean items recalled) as well as the motivation to do the exercise gradually decreased during the semester. Motivation was positively correlated with performance (r=0.77, p<0.05). The results suggest that laboratory findings may provide some applications in education but other variables inherent to the classroom setting must also be considered.Keywords: long-term, episodic memory, consolidation, retrieval, school setting
Procedia PDF Downloads 34210995 The Effects of Microsilis, Super Plasticizer and Air Entrain in Lightweight Expanded Perlite Concrete
Authors: Yousef Zandi, Hoseyn Leka, Mahin Ganadi
Abstract:
This paper presents the results of a laboratory study carried out on effect of using the simultaneous of microsilis, super plasticizer and air entrain additives on compressive strength of light weight perlite concrete. In this study, 63 test specimens with different percentage and mixtures including microsilis, super plasticizer and air entrain were used. 63 test specimens with different mixtures including microsilis and air entrain were also prepared for comparison purposes. In the mixtures, lightweight perlite aggregate, microsilis, super plasticizer, air entrain, cement type I, sand and water were used. Laboratory test results showed that workability of lightweight perlite concrete was increased and compressive strength was released by the use of super plasticizer, without any change in water/cement ratio. We know that compressive strength of concrete is depends on water/cement ratio. Since, it was expected that the use of air entrain and super plasticizer lower water/cement ratio and raised strengths, considerably. It was concluded that use of simultaneous of air entrains and super plasticizer additive were not economical and use of air entrain and microsilis is better than use of air entrain, super plasticizer and microsilis. It was concluded that the best results were obtained by using 10% microsilis and 0.5% air entrain.Keywords: perlite, microsilis, air entrain, super plasticizer
Procedia PDF Downloads 38510994 Application of Web Aided Education on Laboratory of the Physics Course
Authors: Nigmet Koklu, Dundar Yener
Abstract:
Recently, distance education that make use of web technology is used widely all around the world to overcome geographical and time based problems in education. Graphics, animation and other auxiliary visual sources help student to understand the subjects easily. Especially some theoretical courses that are quite difficult to understand such as physics and chemistry require visual material for students to understand topics clearly. In this study, physics applications for laboratory of physics course were developed. All facilities of web-based educational technology were used for students in laboratory studies to avoid making mistakes and to learn better physics subjects.Keywords: physics education, laboratory, web-based education, distance education
Procedia PDF Downloads 52010993 The Quest for Personal Protective Equipment Arc Rating: Implications for Electrical Workers' Safety and Health
Authors: Marcio Bottaro, Luis Eduardo Caires, Thais Ohara de Carvalho, Paulo Futoshi Obase, Hedio Tatizawa
Abstract:
Since the primary numerical metric used to evaluate Personal Protective Equipment – PPE, including protective clothing or other equipment designs, is typically derived from a single arc rating report, researchers and occupational safety professionals have raised significant concerns regarding the reliability of assigning a safety rating based on a single thermal performance test. Moreover, questions arise about the adequacy of determining PPE conformity solely from a single arc flash test. Although it is well known that the arc rated PPE work and show unquestionable evolution in workers’ safety, a tendency to pursue every higher arc rating value is evidenced in the marketing, and in Brazil, it has been a special concern on the reliability of such practice of “select” a more convenient arc rating report to use as base parameter on final PPE test and subsequently certification process. In fact, this procedure is not forbidden and it ends up being supported and encouraged due to the way such tests are conducted according to international standards. Although commonly practiced, variations in test laboratory procedures, as well as inherent variations in materials such as textiles, introduce significant concerns regarding the reliability of higher reference values across batches of final products. This study highlights the discrepancies between claimed arc rating values and those obtained through laboratory testing over time for various textile materials. The findings reveal that focusing on the upper margins of thermal characterization can lead to adverse effects on the final versions of PPE, which are ostensibly ready for worker use. Deterministic failures such as charring, dripping, and breakopen in proof undergarments were observed, with a notable increase in the frequency of these failures in 2024 tests in Brazilian arc flash laboratory. These results underscore the urgent need for advancements in standardization processes to ensure the reliability of PPE and safety of workers.Keywords: arc rating, arc flash protection, arc flash risk, PPE certification, PPE open arc test
Procedia PDF Downloads 1110992 Analysis of Efficiency Production of Grass Black Jelly (Mesona palustris) in Double Scale
Authors: Irvan Adhin Cholilie, Susinggih Wijana, Yusron Sugiarto
Abstract:
The aim of this research is to compare the results of black grass jelly produced using laboratory scale and double scale. In this research, the production from the laboratory scale is using ingredients of 1 kg black grass jelly added with 5 liters of water, while the double scale is using 5 kg black grass jelly and 75 liters of water. The results of organoleptic tests performed by 30 panelists (general) to the sample gels of grass black powder produced from both of laboratory and double scale are not different significantly in color, odor, flavor, and texture. Proximate test results conducted in both of grass black jelly powder produced in laboratory scale and double scale also have no significant differences in all parameters. Grass black jelly powder from double scale contains water, carbohydrate, crude fiber, and yield in the amount of 12,25 %; 43,7 %; 5,89 %; and 16,28 % respectively. The results of the energy efficiency analysis by boiling, draining, evaporation, drying, and milling processes are 85,11 %; 76,97 %; 99,64 %; 99,99% and 99,39% respectively. The utility needs including water needs for each batch amounted 0.1 m3 and cost Rp 220,5 per batch, the electricity needs for each batch is 20.01 kWh and cost Rp 18569.28 per batch, and LPG needs for each batch is 30 kg costed Rp 234,000.00 so that the total cost spent for the process is Rp 252,789.78 .Keywords: black grass jelly, powder, mass balance, energy balance, cost
Procedia PDF Downloads 38710991 Findings in Vascular Catheter Cultures at the Laboratory of Microbiology of General Hospital during One Year
Authors: P. Christodoulou, M. Gerasimou, S. Mantzoukis, N. Varsamis, G. Kolliopoulou, N. Zotos
Abstract:
Abstract— Purpose: The Intensive Care Unit (ICU) environment is conducive to the growth of microorganisms. A variety of microorganisms gain access to the intravascular area and are transported throughout the circulatory system. Therefore, examination of the catheters used in ICU patients is of paramount importance. Material and Method: The culture medium is a catheter tip, which is enriched with Tryptic soy broth (TSB). After one day of incubation, the broth is passaged in the following selective media: Blood, Mac conkey No. 2, chocolate, Mueller Hinton, Chapman, and Saboureaud agar. The above selective media is incubated for 2 days. After this period, if any number of microbial colonies is detected, gram staining is performed and then the microorganisms are identified by biochemical techniques in the automated Microscan (Siemens) system followed by a sensitivity test in the same system using the minimum inhibitory concentration (MIC) technique. The sensitivity test is verified by a Kirby Bauer test. Results: In 2017, the Microbiology Laboratory received 84 catheters from the ICU. 42 were found positive. Of these, S. epidermidis was identified at 8, A. baumannii in 10, K. pneumoniae in 6, P. aeruginosa in 6, P. mirabilis in 3, S. simulans in 1, S. haemolyticus in 4, S. aureus in 3 and S. hominis in 1. Conclusions: The results show that the placement and maintenance of the catheters in ICU patients are relatively successful, despite the unfavorable environment of the unit.Keywords: culture, intensive care unit, microorganisms, vascular catheters
Procedia PDF Downloads 28810990 Determination of Unsaturated Soil Permeability Based on Geometric Factor Development of Constant Discharge Model
Authors: A. Rifa’i, Y. Takeshita, M. Komatsu
Abstract:
After Yogyakarta earthquake in 2006, the main problem that occurred in the first yard of Prambanan Temple is ponding area that occurred after rainfall. Soil characterization needs to be determined by conducting several processes, especially permeability coefficient (k) in both saturated and unsaturated conditions to solve this problem. More accurate and efficient field testing procedure is required to obtain permeability data that present the field condition. One of the field permeability test equipment is Constant Discharge procedure to determine the permeability coefficient. Necessary adjustments of the Constant Discharge procedure are needed to be determined especially the value of geometric factor (F) to improve the corresponding value of permeability coefficient. The value of k will be correlated with the value of volumetric water content (θ) of an unsaturated condition until saturated condition. The principle procedure of Constant Discharge model provides a constant flow in permeameter tube that flows into the ground until the water level in the tube becomes constant. Constant water level in the tube is highly dependent on the tube dimension. Every tube dimension has a shape factor called the geometric factor that affects the result of the test. Geometric factor value is defined as the characteristic of shape and radius of the tube. This research has modified the geometric factor parameters by using empty material tube method so that the geometric factor will change. Saturation level is monitored by using soil moisture sensor. The field test results were compared with the results of laboratory tests to validate the results of the test. Field and laboratory test results of empty tube material method have an average difference of 3.33 x 10-4 cm/sec. The test results showed that modified geometric factor provides more accurate data. The improved methods of constant discharge procedure provide more relevant results.Keywords: constant discharge, geometric factor, permeability coefficient, unsaturated soils
Procedia PDF Downloads 29710989 Effects of Ubiquitous 360° Learning Environment on Clinical Histotechnology Competence
Authors: Mari A. Virtanen, Elina Haavisto, Eeva Liikanen, Maria Kääriäinen
Abstract:
Rapid technological development and digitalization has affected also on higher education. During last twenty years multiple of electronic and mobile learning (e-learning, m-learning) platforms have been developed and have become prevalent in many universities and in the all fields of education. Ubiquitous learning (u-learning) is not that widely known or used. Ubiquitous learning environments (ULE) are the new era of computer-assisted learning. They are based on ubiquitous technology and computing that fuses the learner seamlessly into learning process by using sensing technology as tags, badges or barcodes and smart devices like smartphones and tablets. ULE combines real-life learning situations into virtual aspects and can be flexible used in anytime and anyplace. The aim of this study was to assess the effects of ubiquitous 360 o learning environment on higher education students’ clinical histotechnology competence. A quasi-experimental study design was used. 57 students in biomedical laboratory science degree program was assigned voluntarily to experiment (n=29) and to control group (n=28). Experimental group studied via ubiquitous 360o learning environment and control group via traditional web-based learning environment (WLE) in a 8-week educational intervention. Ubiquitous 360o learning environment (ULE) combined authentic learning environment (histotechnology laboratory), digital environment (virtual laboratory), virtual microscope, multimedia learning content, interactive communication tools, electronic library and quick response barcodes placed into authentic laboratory. Web-based learning environment contained equal content and components with the exception of the use of mobile device, interactive communication tools and quick response barcodes. Competence of clinical histotechnology was assessed by using knowledge test and self-report developed for this study. Data was collected electronically before and after clinical histotechnology course and analysed by using descriptive statistics. Differences among groups were identified by using Wilcoxon test and differences between groups by using Mann-Whitney U-test. Statistically significant differences among groups were identified in both groups (p<0.001). Competence scores in post-test were higher in both groups, than in pre-test. Differences between groups were very small and not statistically significant. In this study the learning environment have developed based on 360o technology and successfully implemented into higher education context. And students’ competence increases when ubiquitous learning environment were used. In the future, ULE can be used as a learning management system for any learning situation in health sciences. More studies are needed to show differences between ULE and WLE.Keywords: competence, higher education, histotechnology, ubiquitous learning, u-learning, 360o
Procedia PDF Downloads 28810988 Challenges for Implementing Standards Compliant with Iso/Iec 17025, for Narcotics and DNA Laboratory’s
Authors: Blerim Olluri
Abstract:
A forensic science laboratory in Kosovo has never been organized at the level of most modern forensic science laboratories. This was made possible after the war of 1999 with the help and support from the United States. The United States Government/ICITAP provided 9.5 million dollars to support this project, this support have greatly benefitted law enforcement in Kosovo. With the establishment of Operative Procedures of Work and the law for Kosovo Agency of Forensic, the accreditation with ISO/IEC 17025 of the KAF labs it becomes mandatory. Since 2012 Laboratory’s DNA/Serology and Narcotics has begun reviewing and harmonizing their procedures according to ISO/IEC 17025. The focus of this work was to create quality manuals, procedures, work instructions, quality documentation and quality records. Furthermore, during this time is done the validation of work methods from scientific qualified personnel of KAF, without any help from other foreign agencies or accreditation body.In October 2014 we had the first evaluation based on ISO 17025 standards. According to the initial report of this assessment we have non conformity in test and Calibration methods method’s, and accommodation and environmental conditions. We identified several issues that are of extreme importance to KAF. One the most important issue is to create a professional group with experts of KAF, which will work in all the obligations, requested from ISO/IEC 17025. As conclusions that we earn in this path of accreditation, are that laboratory’s need to take corrective action, and all nonconformance’s must be addressed and corrective action taken before accreditation can be granted.Keywords: accreditation, assessment, narcotics, DNA
Procedia PDF Downloads 36610987 Effect of Inclusion of Rubber on the Compaction Characteristics of Cement - MSWIFA- Clayey Soil Mixtures
Authors: Gehan Aouf, Diala Tabbal, Abd El Rahim Sabsabi, Rashad Aouf
Abstract:
The aim of this study is to show the effect of adding cement municipal solid incineration fly ash and rubber as stabilizer materials on weak soil. A detailed experimental study was conducted in order to show the viability of using these admixtures in improving the maximum dry density and optimum moisture content of the composite soil. Soil samples were prepared by adding Rubber and Cement to municipal solid waste incineration fly-ash - oil mix at different percentages. Then, a series of laboratory tests were performed, namely: Sieve analysis, Atterberg limits tests, Unconfined compression test, and Proctor tests. Three different percentages of fly ash (10%, 20%, and 30%) MSWFA by total dry weight of soil and three different percentages of Portland cement (10%, 15%, and 20%) by total dry weight of the mix and 0%, 5%, 10% for Rubber by total dry weight of the mix were used to find the optimum value. The test results reveal that adding MSWIFA to the soil up to 20% increased the MDD of the mixture and decreased the OMC, then an opposite trend for results were found when the percentage of MSWIFA exceeded 20%. This is due to the low specific gravity of MSWIFA and to the greater water absorption of MSWIFA. The laboratory tests also indicate that adding Rubber to the mix Soil-MSWIFA-Cement decreases its MDD due to the low specific gravity of rubber and it affects a slight decrease in OMC because the rubber has low absorption of water.Keywords: clayey soil, MSWIFA, proctor test, rubber
Procedia PDF Downloads 12110986 150 KVA Multifunction Laboratory Test Unit Based on Power-Frequency Converter
Authors: Bartosz Kedra, Robert Malkowski
Abstract:
This paper provides description and presentation of laboratory test unit built basing on 150 kVA power frequency converter and Simulink RealTime platform. Assumptions, based on criteria which load and generator types may be simulated using discussed device, are presented, as well as control algorithm structure. As laboratory setup contains transformer with thyristor controlled tap changer, a wider scope of setup capabilities is presented. Information about used communication interface, data maintenance, and storage solution as well as used Simulink real-time features is presented. List and description of all measurements are provided. Potential of laboratory setup modifications is evaluated. For purposes of Rapid Control Prototyping, a dedicated environment was used Simulink RealTime. Therefore, load model Functional Unit Controller is based on a PC computer with I/O cards and Simulink RealTime software. Simulink RealTime was used to create real-time applications directly from Simulink models. In the next step, applications were loaded on a target computer connected to physical devices that provided opportunity to perform Hardware in the Loop (HIL) tests, as well as the mentioned Rapid Control Prototyping process. With Simulink RealTime, Simulink models were extended with I/O cards driver blocks that made automatic generation of real-time applications and performing interactive or automated runs on a dedicated target computer equipped with a real-time kernel, multicore CPU, and I/O cards possible. Results of performed laboratory tests are presented. Different load configurations are described and experimental results are presented. This includes simulation of under frequency load shedding, frequency and voltage dependent characteristics of groups of load units, time characteristics of group of different load units in a chosen area and arbitrary active and reactive power regulation basing on defined schedule.Keywords: MATLAB, power converter, Simulink Real-Time, thyristor-controlled tap changer
Procedia PDF Downloads 32610985 Determination of Small Shear Modulus of Clayey Sand Using Bender Element Test
Authors: R. Sadeghzadegan, S. A. Naeini, A. Mirzaii
Abstract:
In this article, the results of a series of carefully conducted laboratory test program were represented to determine the small strain shear modulus of sand mixed with a range of kaolinite including zero to 30%. This was experimentally achieved using a triaxial cell equipped with bender element. Results indicate that small shear modulus tends to increase, while clay content decreases and effective confining pressure increases. The exponent of stress in the power model regression analysis was not sensitive to the amount of clay content for all sand clay mixtures, while coefficient A was directly affected by change in clay content.Keywords: small shear modulus, bender element test, plastic fines, sand
Procedia PDF Downloads 47610984 Conducting Computational Physics Laboratory Course Using Cloud Storage Space
Authors: Ajay Wadhwa
Abstract:
A Laboratory course on computational physics is different from the conventional lab course on other topics of physics like Mechanics, Heat, Optics, etc. because it involves active participation of the teacher as well as one-to-one interaction between teacher and the student. The course content requires the teacher to teach programming language as well as numerical methods along with their applications in physics. The task becomes more daunting when about 90% of the students in the class have no previous experience of any programming language. In the presented work, we have described a methodology for conducting the computational physics course by using the Google Drive and Dropitto.me cloud storage services. We have evaluated the performance in a class of sixty students by dividing them equally into four groups. One of the groups was made the peer group on whom the presented methodology was tested. The other groups were taught by using conventional method of classroom lectures. In order to assess our methodology, we analyzed the performance of students in four class tests. A study of certain statistical parameters like the mean, standard deviation, and Z-test hypothesis revealed that the cyber methodology based on cloud storage is more efficient than the conventional method of teaching.Keywords: computational Physics, Z-test hypothesis, cloud storage, Google drive
Procedia PDF Downloads 30210983 The Effect of Irradiation Distance on Microhardness of Hybrid Resin Composite Polymerization Using Light-Emitting Diodes
Authors: Deli Mona, Rafika Husni
Abstract:
The aim of this research is to evaluate the effect of lighting distance on surface hardness of light composite resin. We held laboratory experimental research with post-test only group design. The samples used are 30 disc-like hybrid composite resins with the diameter is 6 mm and the thickness is 2 mm, lighted by an LED for 20 seconds. They were divided into 3 groups, and every group was consisted by 10 samples, which were 0 mm, 2 mm, and 5 mm lighting distance group. Every samples group was treated with hardness test, Vicker Hardness Test, then analyzed with one-way ANOVA test to evaluate the effect of lighting distance differences on surface hardness of light composite resin. Statistic test result shown hardness mean change of composite renin between 0 mm and 2 mm lighting distance with 0.00 significance (p<0.05), between 0 mm and 5 mm lighting distance with 0.00 significance (p<0.05), and 2 mm and 5 mm lighting distance with 0.05 significance (p<0.05). According to the result of this research, we concluded that the further lighting distance, the more surface hardness decline of hybrid composite resin.Keywords: composite resin hybrid, tip distance, microhardness, light curing LED
Procedia PDF Downloads 35110982 Laboratory Investigation of Fly Ash Based Geopolymer Stabilized Recycled Asphalt Pavement as a Base Material
Authors: Menglim Hoy, Suksun Horpibulsuk, Arul Arulrajah
Abstract:
The results of laboratory investigation of recycled asphalt pavement (RAP) – fly ash (FA) based geopolymer as a base material is presented in this paper. An alkaline activator, the mixture of NaOH and Na₂SiO₃, is used to synthesis RAP-FA based geopolymer. RAP-FA with water (RAP-FA blend) prepared as a control material. The strength develops and the strength against wet-dry was determined by the unconfined compression strength (UCS) test, then the microstructural properties were examined by scanning electron microscopy (SEM) and X-ray Diffraction (XRD) analysis. The toxicity characteristic leaching procedure (TCLP) test is conducted to measure its leachability of heavy metal. The results show both the RAP-FA blend and geopolymer can be used as a base course as its UCS values meet the minimum strength requirement specified by the Department of Highway, Thailand. The durability test results show the UCS of these materials increases with increasing the number of wet-dry cycles, reaching its peak at six wet-dry cycles. The XRD and SEM analyses indicate strength development of the RAP-FA blend occurs due to chemical reaction between a high Calcium in RAP with a high Silica and Alumina in FA led to producing calcium aluminate hydrate formation. The strength development of the RAP-FA geopolymer occurred resulted from the polymerization reaction. The TCLP results demonstrate there is no environmental risk of these stabilized materials. Furthermore, FA based geopolymer can reduce the leachability of heavy metal in the RAP-FA blend.Keywords: recycled asphalt pavement, geopolymer, heavy metal, microstructure
Procedia PDF Downloads 10110981 A Future Technology: Solar Winged Autonomous Underwater Vehicle Design
Authors: Mohammad Moonesun
Abstract:
One of the most important future technologies is related to solar Autonomous Underwater Vehicles (AUVs). In this technical paper, some aspects of solar winged AUV design are mentioned. The case study is for Arya project. The submarine movement cyclograms, weight quotas for internal equipment, hydrodynamic test results are mentioned, and some other technical notes are discussed here. The main body is the SUBOFF type and has two hydroplanes on the both sides of the body with the NACA0015 cross section. On these two hydroplanes, two 50-W photovoltaic panel will be mounted. Four small hydroplanes with the same cross section of the NACA0015 are arranged at the stern of the body at a 90° angle to each other. This test is performed in National Iranian Marine Laboratory with the length of 402 m.Keywords: AUV, solar, model test, hydrodynamic resistance
Procedia PDF Downloads 13410980 Challenges in Experimental Testing of a Stiff, Overconsolidated Clay
Authors: Maria Konstadinou, Etienne Alderlieste, Anderson Peccin da Silva, Ben Arntz, Leonard van der Bijl, Wouter Verschueren
Abstract:
The shear strength and compression properties of stiff Boom clay from Belgium at the depth of about 30 m has been investigated by means of cone penetration and laboratory testing. The latter consisted of index classification, constant rate of strain, direct, simple shear, and unconfined compression tests. The Boom clay samples exhibited strong swelling tendencies. The suction pressure was measured via different procedures and has been compared to the expected in-situ stress. The undrained shear strength and OCR profile determined from CPTs is not compatible with the experimental measurements, which gave significantly lower values. The observed response can be attributed to the presence of pre-existing discontinuities, as shown in microscale CT scans of the samples. The results of this study demonstrate that the microstructure of the clay prior to testing has an impact on the mechanical behaviour and can cause inconsistencies in the comparison of the laboratory test results with in-situ data.Keywords: boom clay, laboratory testing, overconsolidation ratio, stress-strain response, swelling, undrained shear strength
Procedia PDF Downloads 15010979 Effect of Nano-SiO2 Solution on the Strength Characteristics of Kaolinite
Authors: Reza Ziaie Moayed, Hamidreza Rahmani
Abstract:
Today, with developments in science and technology, there is an excessive potential for the use of nanomaterials in various fields of geotechnical project such as soil stabilization. This study investigates the effect of Nano-SiO2 solution on the unconfined compression strength and Young's elastic modulus of Kaolinite. For this purpose, nano-SiO2 was mixed with kaolinite in five different contents: 1, 2, 3, 4 and 5% by weight of the dry soil and a series of the unconfined compression test with curing time of one-day was selected as laboratory test. Analyses of the tests results show that stabilization of kaolinite with Nano-SiO2 solution can improve effectively the unconfined compression strength of modified soil up to 1.43 times compared to the pure soil.Keywords: kaolinite, Nano-SiO2, stabilization, unconfined compression test, Young's modulus
Procedia PDF Downloads 39610978 Establishing Reference Intervals for Routine Coagulation Tests
Authors: Santina Sahibon, Sivasooriar Sivaneson, Martin Giddy, Nelson Nheu, Siti Sazeelah, Choo Kok Ming, Thuhairah Abdul Rahman, Fatmawati Binti Kamal
Abstract:
Introduction: Establishing population-based reference intervals (RI) are essential when evaluating laboratory test results and for method verification. Our laboratory initiated an exercise to establish RI for routine coagulation profile as part of the method verification procedure and to determine any differences in RI between three analyzers planned to be used in the laboratory. Methodology: 145 blood samples were collected and analysed for activated partial thromboplastin time (aPTT), prothrombin time (PT), international normalized ratio (INR), and fibrinogen] using three coagulation analysers which were CA104, CA660, and CS-2500 (Sysmex, USA). RI was established at 2.5th and 97.5th percentiles. Results: The RI for aPTT between C104, C660 and CS-2500 are (RI: 20.5-30.2 sec), (RI: 21.5-29.2 sec) and (RI: 22.7-30.3 sec) respectively. The RI for PT were (RI: 7.5-10.3 sec), (RI: 9.2- 11.1 sec) and (RI: 9.8-11.9 sec) for C104, CA660 and CS-2500 respectively. INR had an RI of (RI: 0.87- 1.16), (RI: 0.89-1.10) and (0.90-1.11) respectively on CA104, C660 and CS-2500. Fibrinogen RI was (RI: 2.04-4.62 g/L) and (2.05-4.76 g/L) on the CA660 and CS-2500, respectively. Conclusion: The RI was similar across the analytical platforms for aPTT, INR, and fibrinogen. However, CA104 showed lower RI compared to the other two analysers for PT. This highlights the potential variability in results between instruments that need to be addressed when verifying RI.Keywords: coagulation, reference interval, APTT, PT, INR, fibrinogen
Procedia PDF Downloads 19210977 The Dynamic Cone Penetration Test: A Review of Its Correlations and Applications
Authors: Abdulrahman M. Hamid
Abstract:
Dynamic Cone Penetration Test (DCPT) is widely used for field quality assessment of soils. Its application to predict the engineering properties of soil is globally promoted by the fact that it is difficult to obtain undisturbed soil samples, especially when loose or submerged sandy soil is encountered. Detailed discussion will be presented on the current development of DCPT correlations with resilient modulus, relative density, California Bearing Ratio (CBR), unconfined compressive strength and shear strength that have been developed for different materials in both the laboratory and field, as well as on the usage of DCPT in quality control of compaction of earth fills and performance evaluation of pavement layers. In addition, the relationship of the DCPT with other instruments such as falling weight deflectometer, nuclear gauge, soil stiffens gauge, and plate load test will be reported. Lastely, the application of DCPT in Saudi Arabia in recent years will be addressed in this manuscript.Keywords: dynamic cone penetration test, falling weight deflectometer, nuclear gauge, soil stiffens gauge, plate load test, automated dynamic cone penetration
Procedia PDF Downloads 44410976 Anlaytical Studies on Subgrade Soil Using Jute Geotextile
Authors: A. Vinod Kumar, G. Sunny Deol, Rakesh Kumar, B. Chandra
Abstract:
Application of fiber reinforcement in road construction is gaining some interest in enhancing soil strength. In this paper, the natural geotextile material obtained from gunny bags was used due to its vast local availability. Construction of flexible pavement on weaker soil such as clay soils is a significant problem in construction as well as in design due to its expansive characteristics. Jute geotextile (JGT) was used on a foundation layer of flexible pavement on rural roads. This problem will be conquered by increasing the subgrade strength by decreasing sub-base layer thickness by improving their overall pavement strength characteristics which ultimately reduces the cost of construction and leads to an economical design. California Bearing Ratio (CBR), unconfined compressive strength (UCS) and triaxial laboratory tests were conducted on two different soil samples, CI and MI. Weaker soil is reinforced with JGT, JGT+Bitumen. JGT+polythene sheet was varied with heights while performing the laboratory tests. Subgrade strength evaluation was investigated by conducting soak CBR test in the laboratory for clayey and silt soils. Laboratory results reveal that reinforced soak CBR value of clayey soil (CI) observed was 10.35%, and silty soil (MI) was 15.6%. This study intends to develop new technique for reinforcing weaker soil with JGT varying parameters for the need of low volume flexible pavements. It was observed that the performance of JGT is inferior when used with bitumen and polyethylene sheets.Keywords: CBR, jute geotextile, low volume road, weaker soil
Procedia PDF Downloads 446