Search results for: invasive procedure
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2781

Search results for: invasive procedure

2421 Identification of Vehicle Dynamic Parameters by Using Optimized Exciting Trajectory on 3- DOF Parallel Manipulator

Authors: Di Yao, Gunther Prokop, Kay Buttner

Abstract:

Dynamic parameters, including the center of gravity, mass and inertia moments of vehicle, play an essential role in vehicle simulation, collision test and real-time control of vehicle active systems. To identify the important vehicle dynamic parameters, a systematic parameter identification procedure is studied in this work. In the first step of the procedure, a conceptual parallel manipulator (virtual test rig), which possesses three rotational degrees-of-freedom, is firstly proposed. To realize kinematic characteristics of the conceptual parallel manipulator, the kinematic analysis consists of inverse kinematic and singularity architecture is carried out. Based on the Euler's rotation equations for rigid body dynamics, the dynamic model of parallel manipulator and derivation of measurement matrix for parameter identification are presented subsequently. In order to reduce the sensitivity of parameter identification to measurement noise and other unexpected disturbances, a parameter optimization process of searching for optimal exciting trajectory of parallel manipulator is conducted in the following section. For this purpose, the 321-Euler-angles defined by parameterized finite-Fourier-series are primarily used to describe the general exciting trajectory of parallel manipulator. To minimize the condition number of measurement matrix for achieving better parameter identification accuracy, the unknown coefficients of parameterized finite-Fourier-series are estimated by employing an iterative algorithm based on MATLAB®. Meanwhile, the iterative algorithm will ensure the parallel manipulator still keeps in an achievable working status during the execution of optimal exciting trajectory. It is showed that the proposed procedure and methods in this work can effectively identify the vehicle dynamic parameters and could be an important application of parallel manipulator in the fields of parameter identification and test rig development.

Keywords: parameter identification, parallel manipulator, singularity architecture, dynamic modelling, exciting trajectory

Procedia PDF Downloads 261
2420 Cell-Cell Interactions in Diseased Conditions Revealed by Three Dimensional and Intravital Two Photon Microscope: From Visualization to Quantification

Authors: Satoshi Nishimura

Abstract:

Although much information has been garnered from the genomes of humans and mice, it remains difficult to extend that information to explain physiological and pathological phenomena. This is because the processes underlying life are by nature stochastic and fluctuate with time. Thus, we developed novel "in vivo molecular imaging" method based on single and two-photon microscopy. We visualized and analyzed many life phenomena, including common adult diseases. We integrated the knowledge obtained, and established new models that will serve as the basis for new minimally invasive therapeutic approaches.

Keywords: two photon microscope, intravital visualization, thrombus, artery

Procedia PDF Downloads 366
2419 A Comparative Study of Additive and Nonparametric Regression Estimators and Variable Selection Procedures

Authors: Adriano Z. Zambom, Preethi Ravikumar

Abstract:

One of the biggest challenges in nonparametric regression is the curse of dimensionality. Additive models are known to overcome this problem by estimating only the individual additive effects of each covariate. However, if the model is misspecified, the accuracy of the estimator compared to the fully nonparametric one is unknown. In this work the efficiency of completely nonparametric regression estimators such as the Loess is compared to the estimators that assume additivity in several situations, including additive and non-additive regression scenarios. The comparison is done by computing the oracle mean square error of the estimators with regards to the true nonparametric regression function. Then, a backward elimination selection procedure based on the Akaike Information Criteria is proposed, which is computed from either the additive or the nonparametric model. Simulations show that if the additive model is misspecified, the percentage of time it fails to select important variables can be higher than that of the fully nonparametric approach. A dimension reduction step is included when nonparametric estimator cannot be computed due to the curse of dimensionality. Finally, the Boston housing dataset is analyzed using the proposed backward elimination procedure and the selected variables are identified.

Keywords: additive model, nonparametric regression, variable selection, Akaike Information Criteria

Procedia PDF Downloads 261
2418 Report of a Realistic Simulation Training in Using Bougie Guide for Endotracheal Intubation

Authors: Cleto J. Sauer Jr., Rita C. Sauer, Chaider G. Andrade, Dóris F. Rabelo

Abstract:

Some patients with COVID-19 disease and difficult airway characteristics undergo to endotracheal intubation (ETI) procedure. The tracheal introducer, known as the bougie guide, can aid ETI in patients with difficult airway pattern. Realistic simulation (RS) is a methodology utilized for healthcare professionals training. To improve skills in using the bougie guide of physicians from Recôncavo da Bahia region in Brazil, during COVID-19 outbreak, RS training was carried out. Simulated scenario included the Nasco Lifeform realistic simulator for ETI and a bougie guide introducer. Training was a capacitation program organized by the Health Department of Bahia State. Objective: To report effects in participants´ self-confidence perception for using bougie guide after a RS based training. Methods: Descriptive study, secondary data extracted from questionnaires. Priority workplace and previous knowledge about bougie were reported on a preparticipation formulary. Participants also completed pre- and post-training qualitative self-assessment (10-point Likert scale) regarding to self-confidence in using bougie guide. Distribution analysis for qualitative data was performed with Wilcoxon Signed Rank Test, and self-confidence increase analysis in frequency contingency tables with Fisher's exact test. Results: From May to June 2020 a total of 36 physicians participated of training, 25 (69%) from primary care setting, 32 (89%) with no previous knowledge about the bougie guide utilization. For those who had previous knowledge about bougie pre-training self-confidence median was 6,5, and 2 for participants who had not. In overall there was an increase in self-confidence median for bougie utilization. Median (variation) before and after training was 2.5 (1-7) vs. 8 (4-10) (p <0.0001). Among those who had no previous knowledge about bougie (n = 32) an increase in self-confidence greater than 3 points for bougie utilization was reported by 31 vs. 1 participants (p = 0.71). Conclusions: Most of participants had no previous knowledge about using the bougie guide. RS training contributed to self-confidence increase for using bougie for ETI procedure. RS methodology can contribute for training in using the bougie guide for ETI procedure during COVID-19 outbreak.

Keywords: bougie, confidence, COVID-19, endotracheal intubation, realistic simulation

Procedia PDF Downloads 138
2417 Short Teaching Sessions for Emergency Front of Neck Access

Authors: S. M. C. Kelly, A. Hargreaves, S. Hargreaves

Abstract:

Introduction: The Can’t intubate, Can’t ventilate emergency scenario is one which has been shown to be managed badly in the past. Reasons identified included gaps in knowledge of the procedure and the emergency equipment used. We aimed to show an increase in confidence amongst anesthetists and operating department practitioners in the technique following a short tea trolley style teaching intervention. Methods: We carried out the teaching on a one-to-one basis. Two Anaesthetists visited each operating theatre during normal working days. One carried out the teaching session and one took over the intra‐operative care of the patient, releasing the listed anaesthetist for a short teaching session. The teaching was delivered to mixture of students and healthcare professionals, both anaesthetists and anaesthetic practitioners. The equipment includes a trolley, an airway manikin, size 10 scalpel, bougie and size 6.0 tracheal tube. The educator discussed the equipment, performed a demonstration and observed the participants performing the procedure. We asked each person to fill out a pre and post teaching questionnaire, stating their confidence with the procedure. Results: The teaching was delivered to 63 participants in total, which included 21 consultant anaesthetists, 23 trainee doctors and 19 anaesthetic practitioners. The teaching sessions lasted on average 9 minutes (range 5– 15 minutes). All participants reported an increase in confidence in both the equipment and technique in front of neck access. Anaesthetic practitioners reported the greatest increase in confidence (53%), with trainee anaesthetists reporting 27% increase and consultant anaesthetists 22%. Overall, confidence in the performance of emergency front of neck access increased by 31% after the teaching session. Discussion: Short ‘Trolley style’ teaching improves confidence in the equipment and technique used for the emergency front of neck access. This is true for students and for consultant anaesthetists. This teaching style is quick with minimal running costs and is relevant for all anesthetic departments.

Keywords: airway teaching, can't intubate can't ventilate, cricothyroidotomy, front-of-neck

Procedia PDF Downloads 142
2416 Numerical Calculation of Dynamic Response of Catamaran Vessels Based on 3D Green Function Method

Authors: Md. Moinul Islam, N. M. Golam Zakaria

Abstract:

Seakeeping analysis of catamaran vessels in the earlier stages of design has become an important issue as it dictates the seakeeping characteristics, and it ensures safe navigation during the voyage. In the present paper, a 3D numerical method for the seakeeping prediction of catamaran vessel is presented using the 3D Green Function method. Both steady and unsteady potential flow problem is dealt with here. Using 3D linearized potential theory, the dynamic wave loads and the subsequent response of the vessel is computed. For validation of the numerical procedure catamaran vessel composed of twin, Wigley form demi-hull is used. The results of the present calculation are compared with the available experimental data and also with other calculations. The numerical procedure is also carried out for NPL-based round bilge catamaran, and hydrodynamic coefficients along with heave and pitch motion responses are presented for various Froude number. The results obtained by the present numerical method are found to be in fairly good agreement with the available data. This can be used as a design tool for predicting the seakeeping behavior of catamaran ships in waves.

Keywords: catamaran, hydrodynamic coefficients , motion response, 3D green function

Procedia PDF Downloads 211
2415 Experimental Assessment of the Effectiveness of Judicial Instructions and of Expert Testimony in Improving Jurors’ Evaluation of Eyewitness Evidence

Authors: Alena Skalon, Jennifer L. Beaudry

Abstract:

Eyewitness misidentifications can sometimes lead to wrongful convictions of innocent people. This occurs in part because jurors tend to believe confident eyewitnesses even when the identification took place under suggestive conditions. Empirical research demonstrated that jurors are often unaware of the factors that can influence the reliability of eyewitness identification. Most common legal safeguards that are designed to educate jurors about eyewitness evidence are judicial instructions and expert testimony. To date, very few studies assessed the effectiveness of judicial instructions and most of them found that judicial instructions make jurors more skeptical of eyewitness evidence or do not have any effect on jurors’ judgments. Similar results were obtained for expert testimony. However, none of the previous studies focused on the ability of legal safeguards to improve jurors’ assessment of evidence obtained from suggestive identification procedures—this is one of the gaps addressed by this paper. Furthermore, only three studies investigated whether legal safeguards improve the ultimate accuracy of jurors’ judgments—that is, whether after listening to judicial instructions or expert testimony jurors can differentiate between accurate and inaccurate eyewitnesses. This presentation includes two studies. Both studies used genuine eyewitnesses (i.e., eyewitnesses who watched the crime) and manipulated the suggestiveness of identification procedures. The first study manipulated the presence of judicial instructions; the second study manipulated the presence of one of two types of expert testimony: a traditional, verbal expert testimony or expert testimony accompanied by visual aids. All participant watched a video-recording of an identification procedure and of an eyewitness testimony. The results indicated that neither judicial instructions nor expert testimony affected jurors’ judgments. However, consistent with the previous findings, when the identification procedure was non-suggestive, jurors believed accurate eyewitnesses more often than inaccurate eyewitnesses. When the procedure was suggestive, jurors believed accurate and inaccurate eyewitnesses at the same rate. The paper will discuss the implications of these studies and directions for future research.

Keywords: expert testimony, eyewitness evidence, judicial instructions, jurors’ decision making, legal safeguards

Procedia PDF Downloads 172
2414 Test Method Development for Evaluation of Process and Design Effect on Reinforced Tube

Authors: Cathal Merz, Gareth O’Donnell

Abstract:

Coil reinforced thin-walled (CRTW) tubes are used in medicine to treat problems affecting blood vessels within the body through minimally invasive procedures. The CRTW tube considered in this research makes up part of such a device and is inserted into the patient via their femoral or brachial arteries and manually navigated to the site in need of treatment. This procedure replaces the requirement to perform open surgery but is limited by reduction of blood vessel lumen diameter and increase in tortuosity of blood vessels deep in the brain. In order to maximize the capability of these procedures, CRTW tube devices are being manufactured with decreasing wall thicknesses in order to deliver treatment deeper into the body and to allow passage of other devices through its inner diameter. This introduces significant stresses to the device materials which have resulted in an observed increase in the breaking of the proximal segment of the device into two separate pieces after it has failed by buckling. As there is currently no international standard for measuring the mechanical properties of these CRTW tube devices, it is difficult to accurately analyze this problem. The aim of the current work is to address this discrepancy in the biomedical device industry by developing a measurement system that can be used to quantify the effect of process and design changes on CRTW tube performance, aiding in the development of better performing, next generation devices. Using materials testing frames, micro-computed tomography (micro-CT) imaging, experiment planning, analysis of variance (ANOVA), T-tests and regression analysis, test methods have been developed for assessing the impact of process and design changes on the device. The major findings of this study have been an insight into the suitability of buckle and three-point bend tests for the measurement of the effect of varying processing factors on the device’s performance, and guidelines for interpreting the output data from the test methods. The findings of this study are of significant interest with respect to verifying and validating key process and design changes associated with the device structure and material condition. Test method integrity evaluation is explored throughout.

Keywords: neurovascular catheter, coil reinforced tube, buckling, three-point bend, tensile

Procedia PDF Downloads 113
2413 Pharmaceutical Scale up for Solid Dosage Forms

Authors: A. Shashank Tiwari, S. P. Mahapatra

Abstract:

Scale-up is defined as the process of increasing batch size. Scale-up of a process viewed as a procedure for applying the same process to different output volumes. There is a subtle difference between these two definitions: batch size enlargement does not always translate into a size increase of the processing volume. In mixing applications, scale-up is indeed concerned with increasing the linear dimensions from the laboratory to the plant size. On the other hand, processes exist (e.g., tableting) where the term ‘scale-up’ simply means enlarging the output by increasing the speed. To complete the picture, one should point out special procedures where an increase of the scale is counterproductive and ‘scale-down’ is required to improve the quality of the product. In moving from Research and Development (R&D) to production scale, it is sometimes essential to have an intermediate batch scale. This is achieved at the so-called pilot scale, which is defined as the manufacturing of drug product by a procedure fully representative of and simulating that used for full manufacturing scale. This scale also makes it possible to produce enough products for clinical testing and to manufacture samples for marketing. However, inserting an intermediate step between R&D and production scales does not, in itself, guarantee a smooth transition. A well-defined process may generate a perfect product both in the laboratory and the pilot plant and then fail quality assurance tests in production.

Keywords: scale up, research, size, batch

Procedia PDF Downloads 407
2412 Influence of Pressure from Compression Textile Bands: Their Using in the Treatment of Venous Human Leg Ulcers

Authors: Bachir Chemani, Rachid Halfaoui

Abstract:

The aim of study was to evaluate pressure distribution characteristics of the elastic textile bandages using two instrumental techniques: a prototype Instrument and a load Transference. The prototype instrument which simulates shape of real leg has pressure sensors which measure bandage pressure. Using this instrument, the results show that elastic textile bandages presents different pressure distribution characteristics and none produces a uniform distribution around lower limb. The load transference test procedure is used to determine whether a relationship exists between elastic textile bandage structure and pressure distribution characteristics. The test procedure assesses degree of load, directly transferred through a textile when loads series are applied to bandaging surface. A range of weave fabrics was produced using needle weaving machine and a sewing technique. A textile bandage was developed with optimal characteristics far superior pressure distribution than other bandages. From results, we find that theoretical pressure is not consistent exactly with practical pressure. It is important in this study to make a practical application for specialized nurses in order to verify the results and draw useful conclusions for predicting the use of this type of elastic band.

Keywords: textile, cotton, pressure, venous ulcers, elastic

Procedia PDF Downloads 355
2411 Human Performance Evaluating of Advanced Cardiac Life Support Procedure Using Fault Tree and Bayesian Network

Authors: Shokoufeh Abrisham, Seyed Mahmoud Hossieni, Elham Pishbin

Abstract:

In this paper, a hybrid method based on the fault tree analysis (FTA) and Bayesian networks (BNs) are employed to evaluate the team performance quality of advanced cardiac life support (ACLS) procedures in emergency department. According to American Heart Association (AHA) guidelines, a category relying on staff action leading to clinical incidents and also some discussions with emergency medicine experts, a fault tree model for ACLS procedure is obtained based on the human performance. The obtained FTA model is converted into BNs, and some different scenarios are defined to demonstrate the efficiency and flexibility of the presented model of BNs. Also, a sensitivity analysis is conducted to indicate the effects of team leader presence and uncertainty knowledge of experts on the quality of ACLS. The proposed model based on BNs shows that how the results of risk analysis can be closed to reality comparing to the obtained results based on only FTA in medical procedures.

Keywords: advanced cardiac life support, fault tree analysis, Bayesian belief networks, numan performance, healthcare systems

Procedia PDF Downloads 142
2410 New Approach for Melanoma Skin Cancer Controled Releasing Drugs for Neutron Capture Therapy: A Review

Authors: Lucas Bernardes Naves, Luis Almeida

Abstract:

The paper includes a review concerning the use of some composites including poly(lactide-co-glycolide) (PGLA), zeolite and Gadopentetic acid (Gd-DTPA) loaded chitosan nanoparticles (Gd-nanoCPs) in order to establish a new alternative for the treatment of Melanoma Skin Cancer. The main goal of this paper it to make a review of what scientist have done in the last few years, as well as to propose a less invasive therapy for skin cancer, by using Hydrocolloid, based on PLGA coated with Gd-nanoCPs for Neutron Capture Therapy.

Keywords: cancer therapy, dressing polymers, melanoma, wound healing

Procedia PDF Downloads 487
2409 Nutritional Impact in Patients Who Underwent Sleeve-Type Bariatric Surgery

Authors: Melissa Mattos, Camila Lima, Ibraim Castro, Augusto Carioca, Saulo Magalhães, Paula Freitas, Keciany Oliveira

Abstract:

Obesity is a chronic, multifactorial, relapsing disease that has increased dramatically over the years. Its control is considered a public health issue, and more and more treatments and interventions are being studied to reduce its prevalence. When interventions in lifestyle and the use of drugs do not generate lasting results, bariatric procedures emerge as a resource for obesity control. The main guidelines for the treatment of obesity emphasize the need for pre-procedure and post-procedure nutritional monitoring to avoid nutritional deficiencies that may occur. The individual who undergoes bariatric surgery needs to understand the changes that will be necessary for life in view of the intense anatomical and metabolic changes that result from surgical techniques. To assess the nutritional profile of patients who undergo bariatric surgery, we analyzed data from the medical records of all people who underwent sleeve-type bariatric surgery from January to June 2022 at a clinic in the City of Fortaleza. 38 patients were analyzed, 32 women and 6 men in the pre-surgical period, 6 and 12 months after surgery. The data showed an average weight loss of 24.45% at 6 months and 30.85% at 12 months, with a reduction of 21.32% and 30.41%, respectively, in the fat percentage, also indicating that 13.15% used drugs for weight loss during this period, leading to reflection on the isolated long-term efficacy of bariatric surgery, requiring multidisciplinary follow-up for a change in lifestyle. Only 12 individuals, corresponding to 31.57%, reached eutrophic BMI 12 months after surgery, 20 individuals remained overweight, corresponding to 52.63% of the sample, and 6 individuals (15.78%) remained in the BMI obese class I. As for body composition, there was a 52.39% reduction in fat mass and a 12.82% reduction in muscle mass, and 21% of individuals underwent cholecystectomy. Sleeve-type bariatric surgery promoted significant weight loss after 1 year of the procedure, with a reduction in body fat percentage and fat mass. Most patients were still overweight and had a significant reduction in muscle mass.

Keywords: bariatric surgery, sleeve gastrectomy, obesity, sleeve

Procedia PDF Downloads 64
2408 The Implication of Augmentation Cystoplasty with Mitrofanoff Channel on Reproduction Age Group and Outcome of Pregnancy

Authors: Amal A. Qedrah, Sofia A. Malik, Madiha Akbar

Abstract:

The aim of this article is to share a rare clinical case of pregnancy and surgical delivery in a patient who has undergone augmentation cystoplasty with mitrofanoff channel in the past. Methods: This case report is about a woman who conceived naturally at the age of 27, previously underwent augmentation cystoplasty at the age of 10 years with mitrofanoff procedure using self-clean intermittent catheterization. Furthermore, this pregnancy was complicated by the presence of preeclampsia diagnosed at term and PROM. Following the failure of induction for intrapartum preeclampsia, the patient delivered a healthy baby via low transverse cesarean section at 38 weeks done at Latifa Hospital, Dubai. Conclusion: The procedure is done at a pediatric or young age, after which most patients reach reproductive age. There is no contraindication to pregnancy vaginally or surgically; however, this case was complicated by preeclampsia, due to which this patient was taken for a cesarean section. It is advisable to consult a urologist frequently along with taking regular bacteriological urine samples and blood samples with renal ultrasonography for the evaluation of the kidney. Antibacterial treatment or prophylaxis should be used during pregnancy if necessary and intermittent self-catherization is mostly performed routinely. It is also important to have a urologist on standby during the surgery in order to avoid and/or fix any complications that might come forth.

Keywords: augmentation cystoplasty, cesarean section, delivery, mitrofanoff channel

Procedia PDF Downloads 153
2407 Least Squares Solution for Linear Quadratic Gaussian Problem with Stochastic Approximation Approach

Authors: Sie Long Kek, Wah June Leong, Kok Lay Teo

Abstract:

Linear quadratic Gaussian model is a standard mathematical model for the stochastic optimal control problem. The combination of the linear quadratic estimation and the linear quadratic regulator allows the state estimation and the optimal control policy to be designed separately. This is known as the separation principle. In this paper, an efficient computational method is proposed to solve the linear quadratic Gaussian problem. In our approach, the Hamiltonian function is defined, and the necessary conditions are derived. In addition to this, the output error is defined and the least-square optimization problem is introduced. By determining the first-order necessary condition, the gradient of the sum squares of output error is established. On this point of view, the stochastic approximation approach is employed such that the optimal control policy is updated. Within a given tolerance, the iteration procedure would be stopped and the optimal solution of the linear-quadratic Gaussian problem is obtained. For illustration, an example of the linear-quadratic Gaussian problem is studied. The result shows the efficiency of the approach proposed. In conclusion, the applicability of the approach proposed for solving the linear quadratic Gaussian problem is highly demonstrated.

Keywords: iteration procedure, least squares solution, linear quadratic Gaussian, output error, stochastic approximation

Procedia PDF Downloads 172
2406 Reliability Analysis of Soil Liquefaction Based on Standard Penetration: A Case Study in Babol City

Authors: Mehran Naghizaderokni, Asscar Janalizadechobbasty

Abstract:

There are more probabilistic and deterministic liquefaction evaluation procedures in order to judge whether liquefaction will occur or not. A review of this approach reveals that there is a need for a comprehensive procedure that accounts for different sources of uncertainty in liquefaction evaluation. In fact, for the same set of input parameters, different methods provide different factors of safety and/or probabilities of liquefaction. To account for the different uncertainties, including both the model and measurement uncertainties, reliability analysis is necessary. This paper has obtained information from Standard Penetration Test (SPT) and some empirical approaches such as: Seed et al, Highway bridge of Japan approach to soil liquefaction, The Overseas Coastal Area Development Institute of Japan (OCDI) and reliability method to studying potential of liquefaction in soil of Babol city in the north of Iran are compared. Evaluation potential of liquefaction in soil of Babol city is an important issue since the soil of some area contains sand, seismic area, increasing level of underground waters and consequently saturation of soil; therefore, one of the most important goals of this paper is to gain suitable recognition of liquefaction potential and find the most appropriate procedure of evaluation liquefaction potential to decrease related damages.

Keywords: reliability analysis, liquefaction, Babol, civil, construction and geological engineering

Procedia PDF Downloads 494
2405 Charcoal Production from Invasive Species: Suggested Shift for Increased Household Income and Forest Plant Diversity in Nepal

Authors: Kishor Prasad Bhatta, Suman Ghimire, Durga Prasad Joshi

Abstract:

Invasive Alien Species (IAS) are considered waste forest resources in Nepal. The rapid expansion of IAS is one of the nine main drivers of forest degradation, though the extent and distribution of this species are not well known. Further, the knowledge of the impact of IAS removal on forest plant diversity is hardly known, and the possibilities of income generation from them at the grass-root communities are rarely documented. Systematic sampling of 1% with nested circular plots of 500 square meters was performed in IAS removed and non-removed area, each of 30 hectares in Udayapur Community Forest User Group (CFUG), Chitwan, central Nepal to observe whether the removal of IAS contributed to an increase in plant diversity. In addition, ten entrepreneurs of Udaypur CFUG, involved in the charcoal production, briquette making and marketing were interviewed and interacted as well as their record keeping booklets were reviewed to understand if the charcoal production contributed to their income and employment. The average annual precipitation and temperature of the study area is 2100 mm and 34 degree Celsius respectively with Shorea robusta as main tree species and Eupatorium odoratum as dominant IAS. All the interviewed households were from the ̔below-poverty-line’ category as per Community Forestry Guidelines. A higher Shannon-Weiner plant diversity index at regeneration level was observed in IAS removed areas (2.43) than in control site (1.95). Furthermore, the number of tree seedlings and saplings in the IAS harvested blocks were significantly higher (p < 0.005) compared to the unharvested one. The sale of charcoal produced through the pyrolysis of IAS in ̔ Bio-energy kilns’ contributed for an average increased income of 30.95 % (Nepalese rupees 31,000) of the involved households. Despite above factors, some operational policy hurdles related to charcoal transport and taxation existed at field level. This study suggests that plant diversity could be increased through the removal of IAS, and considerable economic benefits could be achieved if charcoal is substantially produced and utilized.

Keywords: briquette, economic benefits, pyrolysis, regeneration

Procedia PDF Downloads 270
2404 Microscopic Analysis of Interfacial Transition Zone of Cementitious Composites Prepared by Various Mixing Procedures

Authors: Josef Fládr, Jiří Němeček, Veronika Koudelková, Petr Bílý

Abstract:

Mechanical parameters of cementitious composites differ quite significantly based on the composition of cement matrix. They are also influenced by mixing times and procedure. The research presented in this paper was aimed at identification of differences in microstructure of normal strength (NSC) and differently mixed high strength (HSC) cementitious composites. Scanning electron microscopy (SEM) investigation together with energy dispersive X-ray spectroscopy (EDX) phase analysis of NSC and HSC samples was conducted. Evaluation of interfacial transition zone (ITZ) between the aggregate and cement matrix was performed. Volume share, thickness, porosity and composition of ITZ were studied. In case of HSC, samples obtained by several different mixing procedures were compared in order to find the most suitable procedure. In case of NSC, ITZ was identified around 40-50% of aggregate grains and its thickness typically ranged between 10 and 40 µm. Higher porosity and lower share of clinker was observed in this area as a result of increased water-to-cement ratio (w/c) and the lack of fine particles improving the grading curve of the aggregate. Typical ITZ with lower content of Ca was observed only in one HSC sample, where it was developed around less than 15% of aggregate grains. The typical thickness of ITZ in this sample was similar to ITZ in NSC (between 5 and 40 µm). In the remaining four HSC samples, no ITZ was observed. In general, the share of ITZ in HSC samples was found to be significantly smaller than in NSC samples. As ITZ is the weakest part of the material, this result explains to large extent the improved mechanical properties of HSC compared to NSC. Based on the comparison of characteristics of ITZ in HSC samples prepared by different mixing procedures, the most suitable mixing procedure from the point of view of properties of ITZ was identified.

Keywords: electron diffraction spectroscopy, high strength concrete, interfacial transition zone, normal strength concrete, scanning electron microscopy

Procedia PDF Downloads 287
2403 Force Sensor for Robotic Graspers in Minimally Invasive Surgery

Authors: Naghmeh M. Bandari, Javad Dargahi, Muthukumaran Packirisamy

Abstract:

Robot-assisted minimally invasive surgery (RMIS) has been widely performed around the world during the last two decades. RMIS demonstrates significant advantages over conventional surgery, e.g., improving the accuracy and dexterity of a surgeon, providing 3D vision, motion scaling, hand-eye coordination, decreasing tremor, and reducing x-ray exposure for surgeons. Despite benefits, surgeons cannot touch the surgical site and perceive tactile information. This happens due to the remote control of robots. The literature survey identified the lack of force feedback as the riskiest limitation in the existing technology. Without the perception of tool-tissue contact force, the surgeon might apply an excessive force causing tissue laceration or insufficient force causing tissue slippage. The primary use of force sensors has been to measure the tool-tissue interaction force in real-time in-situ. Design of a tactile sensor is subjected to a set of design requirements, e.g., biocompatibility, electrical-passivity, MRI-compatibility, miniaturization, ability to measure static and dynamic force. In this study, a planar optical fiber-based sensor was proposed to mount at the surgical grasper. It was developed based on the light intensity modulation principle. The deflectable part of the sensor was a beam modeled as a cantilever Euler-Bernoulli beam on rigid substrates. A semi-cylindrical indenter was attached to the bottom surface the beam at the mid-span. An optical fiber was secured at both ends on the same rigid substrates. The indenter was in contact with the fiber. External force on the sensor caused deflection in the beam and optical fiber simultaneously. The micro-bending of the optical fiber would consequently result in light power loss. The sensor was simulated and studied using finite element methods. A laser light beam with 800nm wavelength and 5mW power was used as the input to the optical fiber. The output power was measured using a photodetector. The voltage from photodetector was calibrated to the external force for a chirp input (0.1-5Hz). The range, resolution, and hysteresis of the sensor were studied under monotonic and harmonic external forces of 0-2.0N with 0 and 5Hz, respectively. The results confirmed the validity of proposed sensing principle. Also, the sensor demonstrated an acceptable linearity (R2 > 0.9). A minimum external force was observed below which no power loss was detectable. It is postulated that this phenomenon is attributed to the critical angle of the optical fiber to observe total internal reflection. The experimental results were of negligible hysteresis (R2 > 0.9) and in fair agreement with the simulations. In conclusion, the suggested planar sensor is assessed to be a cost-effective solution, feasible, and easy to use the sensor for being miniaturized and integrated at the tip of robotic graspers. Geometrical and optical factors affecting the minimum sensible force and the working range of the sensor should be studied and optimized. This design is intrinsically scalable and meets all the design requirements. Therefore, it has a significant potential of industrialization and mass production.

Keywords: force sensor, minimally invasive surgery, optical sensor, robotic surgery, tactile sensor

Procedia PDF Downloads 224
2402 Automatic Differential Diagnosis of Melanocytic Skin Tumours Using Ultrasound and Spectrophotometric Data

Authors: Kristina Sakalauskiene, Renaldas Raisutis, Gintare Linkeviciute, Skaidra Valiukeviciene

Abstract:

Cutaneous melanoma is a melanocytic skin tumour, which has a very poor prognosis while is highly resistant to treatment and tends to metastasize. Thickness of melanoma is one of the most important biomarker for stage of disease, prognosis and surgery planning. In this study, we hypothesized that the automatic analysis of spectrophotometric images and high-frequency ultrasonic 2D data can improve differential diagnosis of cutaneous melanoma and provide additional information about tumour penetration depth. This paper presents the novel complex automatic system for non-invasive melanocytic skin tumour differential diagnosis and penetration depth evaluation. The system is composed of region of interest segmentation in spectrophotometric images and high-frequency ultrasound data, quantitative parameter evaluation, informative feature extraction and classification with linear regression classifier. The segmentation of melanocytic skin tumour region in ultrasound image is based on parametric integrated backscattering coefficient calculation. The segmentation of optical image is based on Otsu thresholding. In total 29 quantitative tissue characterization parameters were evaluated by using ultrasound data (11 acoustical, 4 shape and 15 textural parameters) and 55 quantitative features of dermatoscopic and spectrophotometric images (using total melanin, dermal melanin, blood and collagen SIAgraphs acquired using spectrophotometric imaging device SIAscope). In total 102 melanocytic skin lesions (including 43 cutaneous melanomas) were examined by using SIAscope and ultrasound system with 22 MHz center frequency single element transducer. The diagnosis and Breslow thickness (pT) of each MST were evaluated during routine histological examination after excision and used as a reference. The results of this study have shown that automatic analysis of spectrophotometric and high frequency ultrasound data can improve non-invasive classification accuracy of early-stage cutaneous melanoma and provide supplementary information about tumour penetration depth.

Keywords: cutaneous melanoma, differential diagnosis, high-frequency ultrasound, melanocytic skin tumours, spectrophotometric imaging

Procedia PDF Downloads 266
2401 Just a Heads Up: Approach to Head Shape Abnormalities

Authors: Noreen Pulte

Abstract:

Prior to the 'Back to Sleep' Campaign in 1992, 1 of every 300 infants seen by Advanced Practice Providers had plagiocephaly. Insufficient attention is given to plagiocephaly and brachycephaly diagnoses in practice and pediatric education. In this talk, Nurse Practitioners and Pediatric Providers will be able to: (1) identify red flags associated with head shape abnormalities, (2) learn techniques they can teach parents to prevent head shape abnormalities, and (3) differentiate between plagiocephaly, brachycephaly, and craniosynostosis. The presenter is a Primary Care Pediatric Nurse Practitioner at Ann & Robert H. Lurie Children's Hospital of Chicago and the primary provider for its head shape abnormality clinics. She will help participants translate key information obtained from birth history, review of systems, and developmental history to understand risk factors for head shape abnormalities and progression of deformities. Synostotic and non-synostotic head shapes will be explained to help participants differentiate plagiocephaly and brachycephaly from synostotic head shapes. This knowledge is critical for the prompt referral of infants with craniosynostosis for surgical evaluation and correction. Rapid referral for craniosynostosis can possibly direct the patient to a minimally invasive surgical procedure versus a craniectomy. As for plagiocephaly and brachycephaly, this timely referral can also aid in a physical therapy referral if necessitated, which treats torticollis and aids in improving head shape. A well-timed referral to a head shape clinic can possibly eliminate the need for a helmet and/or minimize the time in a helmet. Practitioners will learn the importance of obtaining head measurements using calipers. The presenter will explain head calculations and how the calculations are interpreted to determine the severity of the head shape abnormalities. Severity defines the treatment plan. Participants will learn when to refer patients to a head shape abnormality clinic and techniques they should teach parents to perform while waiting for the referral appointment. The purpose, mechanics, and logistics of helmet therapy, including optimal time to initiate helmet therapy, recommended helmet wear-time, and tips for helmet therapy compliance, will be described. Case scenarios will be incorporated into the presenter's presentation to support learning. The salient points of the case studies will be explained and discussed. Practitioners will be able to immediately translate the knowledge and skills gained in this presentation into their clinical practice.

Keywords: plagiocephaly, brachycephaly, craniosynostosis, red flags

Procedia PDF Downloads 92
2400 Closed Mitral Valvotomy: A Safe and Promising Procedure

Authors: Sushil Kumar Singh, Kumar Rahul, Vivek Tewarson, Sarvesh Kumar, Shobhit Kumar

Abstract:

Objective: Rheumatic mitral stenosis continues to be a major public health problem in developing countries. When the left atrium (LA) is unable to fill the left ventricle (LV) at normal LA pressures due to impaired relaxation and impaired compliance, diastolic dysfunction occurs. The assessment of left ventricular (LV) diastolic function and filling pressures is of clinical importance to identify underlying cardiac disease, its treatment, and to assess prognosis. 2D echocardiography can detect diastolic dysfunction with excellent sensitivity and minimal risk when compared to the gold standard of invasive pressure-volume measurements. Material and Method: This was a one-year study consisting of twenty-nine patients of isolated rheumatic severe mitral stenosis. Data was analyzed preoperative and post operative (at one month follow-up). Transthoracic 2D echocardiographic parameters of the diastolic function are transmitral flow, pulmonary venous flow, mitral annular tissue doppler, and color M-mode doppler. In our study, mitral valve orifice area, ejection fraction, deceleration time, E/A-wave, E/E’-wave, myocardial performance index of left ventricle (Tei index ), and Mitral inflow propagation velocity were included for echocardiographic evaluation. The statistical analysis was performed on SPSS Version 15.0 statistical analysis software. Result: Twenty-nine patients underwent successful closed mitral commissurotomy for isolated mitral stenosis. The outcome measures were observed pre-operatively and at one-month follow-up. The majority of patients were in NYHA grade III (69.0%) in the preoperative period, which improved to NYHA grade I (48.3%) after closed mitral commissurotomy. Post-surgery mitral valve area increased from 0.77 ± 0.13 to 2.32 ± 0.26 cm, ejection fraction increased from 61.38 ± 4.61 to 64.79 ± 3.22. There was a decrease in deceleration time from 231.55 ± 49.31 to 168.28 ± 14.30 ms, E/A ratio from 1.70 ± 0.54 from 0.89 ± 0.39, E/E’ ratio from 14.59 ± 3.34 to 8.86 ± 3.03. In addition, there was improvement in TIE index from 0.50 ± 0.03 to 0.39 ± 0.06 and mitral inflow propagation velocity from 47.28 ± 3.71 to 57.86 ± 3.19 cm/sec. In peri-operative and follow-up, there was no incidence of severe mitral regurgitation (MR). There was no thromboembolic incident and no mortality.

Keywords: closed mitral valvotomy, mitral stenosis, open mitral commissurotomy, balloon mitral valvotomy

Procedia PDF Downloads 81
2399 Interventional Radiology Perception among Medical Students

Authors: Shujon Mohammed Alazzam, Sarah Saad Alamer, Omar Hassan Kasule, Lama Suliman Aleid, Mohammad Abdulaziz Alakeel, Boshra Mosleh Alanazi, Abdullah Abdulelah Altowairqi, Yahya Ali Al-Asiri

Abstract:

Background: Interventional radiology (IR) is a specialized field within radiology that diagnose and treat several conditions through a minimally invasive surgical procedure that involves the use of various radiological techniques. In the last few years, the role of IR has expanded to include a variety of organ systems which have been led to an increase in demand for these Specialties. The level of knowledge regarding IR is relatively low in general. In this study, we aimed to investigate the perceptions of interventional radiology (IR) as a specialty among medical students and medical interns in Riyadh, Saudi Arabia. Methodology: This study was a cross section. The target population is medical students in January 2023 in Riyadh city, KSA. We used the questionnaire for face-to-face interviews with voluntary participants to assess their knowledge of Interventional radiology. Permission was taken from participants to use their information. Assuring them that the data in this study was used only for scientific purposes. Results: According to the inclusion criteria, a total of 314 students participated in the study. (49%) of the participants were in the preclinical years, and (51%) were in the clinical years. The findings indicate more than half of the students think that they had good information about IR (58%), while (42%) reported that they had poor information and knowledge about IR. Only (28%) of students were planning to take an elective and radiology rotation, (and 27%) said they would consider a career in IR. (73%) of the participants who would not consider a career in IR, the highest reasons in order were due to "I do not find it interesting" (45%), then "Radiation exposure" (14%). Around half (48%) thought that an IRs must complete a residency training program in both radiology and surgery, and just (36%) of the students believe that an IRs must finish training in radiology. Our data show the procedures performed by IRs that (66%) lower limb angioplasty and stenting (58%) Cardiac angioplasty or stenting. (68%) of the students were familiar with angioplasty. When asked about the source of exposure to angioplasty, the majority (46%) were from a cardiologist, (and 16%) were from the interventional radiologist. Regarding IR career prospects, (78%) of the students believe that IRs have good career prospects. In conclusion, our findings reveal that the perception and exposure to IR among medical students and interns are generally poor. This has a direct influence on the student's decision regarding IR as a career path. Recommendations to attract medical students and promote IR as a career should be increased knowledge among medical students and future physicians through early exposure to IR, and this will promote the specialty's growth; also, involvement of the Saudi Interventional Radiology Society and Radiological Society of Saudi Arabia is essential.

Keywords: knowledge, medical students, perceptions, radiology, interventional radiology, Saudi Arabia

Procedia PDF Downloads 81
2398 A Review of Current Knowledge on Assessment of Precast Structures Using Fragility Curves

Authors: E. Akpinar, A. Erol, M.F. Cakir

Abstract:

Precast reinforced concrete (RC) structures are excellent alternatives for construction world all over the globe, thanks to their rapid erection phase, ease mounting process, better quality and reasonable prices. Such structures are rather popular for industrial buildings. For the sake of economic importance of such industrial buildings as well as significance of safety, like every other type of structures, performance assessment and structural risk analysis are important. Fragility curves are powerful tools for damage projection and assessment for any sort of building as well as precast structures. In this study, a comparative review of current knowledge on fragility analysis of industrial precast RC structures were presented and findings in previous studies were compiled. Effects of different structural variables, parameters and building geometries as well as soil conditions on fragility analysis of precast structures are reviewed. It was aimed to briefly present the information in the literature about the procedure of damage probability prediction including fragility curves for such industrial facilities. It is found that determination of the aforementioned structural parameters as well as selecting analysis procedure are critically important for damage prediction of industrial precast RC structures using fragility curves.

Keywords: damage prediction, fragility curve, industrial buildings, precast reinforced concrete structures

Procedia PDF Downloads 187
2397 The Healthcare Costs of BMI-Defined Obesity among Adults Who Have Undergone a Medical Procedure in Alberta, Canada

Authors: Sonia Butalia, Huong Luu, Alexis Guigue, Karen J. B. Martins, Khanh Vu, Scott W. Klarenbach

Abstract:

Obesity is associated with significant personal impacts on health and has a substantial economic burden on payers due to increased healthcare use. A contemporary estimate of the healthcare costs associated with obesity at the population level are lacking. This evidence may provide further rationale for weight management strategies. Methods: Adults who underwent a medical procedure between 2012 and 2019 in Alberta, Canada were categorized into the investigational cohort (had body mass index [BMI]-defined class 2 or 3 obesity based on a procedure-associated code) and the control cohort (did not have the BMI procedure-associated code); those who had bariatric surgery were excluded. Characteristics were presented and healthcare costs ($CDN) determined over a 1-year observation period (2019/2020). Logistic regression and a generalized linear model with log link and gamma distribution were used to assess total healthcare costs (comprised of hospitalizations, emergency department visits, ambulatory care visits, physician visits, and outpatient prescription drugs); potential confounders included age, sex, region of residence, and whether the medical procedure was performed within 6-months before the observation period in the partial adjustment, and also the type of procedure performed, socioeconomic status, Charlson Comorbidity Index (CCI), and seven obesity-related health conditions in the full adjustment. Cost ratios and estimated cost differences with 95% confidence intervals (CI) were reported; incremental cost differences within the adjusted models represent referent cases. Results: The investigational cohort (n=220,190) was older (mean age: 53 standard deviation [SD]±17 vs 50 SD±17 years), had more females (71% vs 57%), lived in rural areas to a greater extent (20% vs 14%), experienced a higher overall burden of disease (CCI: 0.6 SD±1.3 vs 0.3 SD±0.9), and were less socioeconomically well-off (material/social deprivation was lower [14%/14%] in the most well-off quintile vs 20%/19%) compared with controls (n=1,955,548). Unadjusted total healthcare costs were estimated to be 1.77-times (95% CI: 1.76, 1.78) higher in the investigational versus control cohort; each healthcare resource contributed to the higher cost ratio. After adjusting for potential confounders, the total healthcare cost ratio decreased, but remained higher in the investigational versus control cohort (partial adjustment: 1.57 [95% CI: 1.57, 1.58]; full adjustment: 1.21 [95% CI: 1.20, 1.21]); each healthcare resource contributed to the higher cost ratio. Among urban-dwelling 50-year old females who previously had non-operative procedures, no procedures performed within 6-months before the observation period, a social deprivation index score of 3, a CCI score of 0.32, and no history of select obesity-related health conditions, the predicted cost difference between those living with and without obesity was $386 (95% CI: $376, $397). Conclusions: If these findings hold for the Canadian population, one would expect an estimated additional $3.0 billion per year in healthcare costs nationally related to BMI-defined obesity (based on an adult obesity rate of 26% and an estimated annual incremental cost of $386 [21%]); incremental costs are higher when obesity-related health conditions are not adjusted for. Results of this study provide additional rationale for investment in interventions that are effective in preventing and treating obesity and its complications.

Keywords: administrative data, body mass index-defined obesity, healthcare cost, real world evidence

Procedia PDF Downloads 105
2396 Prediction of Alzheimer's Disease Based on Blood Biomarkers and Machine Learning Algorithms

Authors: Man-Yun Liu, Emily Chia-Yu Su

Abstract:

Alzheimer's disease (AD) is the public health crisis of the 21st century. AD is a degenerative brain disease and the most common cause of dementia, a costly disease on the healthcare system. Unfortunately, the cause of AD is poorly understood, furthermore; the treatments of AD so far can only alleviate symptoms rather cure or stop the progress of the disease. Currently, there are several ways to diagnose AD; medical imaging can be used to distinguish between AD, other dementias, and early onset AD, and cerebrospinal fluid (CSF). Compared with other diagnostic tools, blood (plasma) test has advantages as an approach to population-based disease screening because it is simpler, less invasive also cost effective. In our study, we used blood biomarkers dataset of The Alzheimer’s disease Neuroimaging Initiative (ADNI) which was funded by National Institutes of Health (NIH) to do data analysis and develop a prediction model. We used independent analysis of datasets to identify plasma protein biomarkers predicting early onset AD. Firstly, to compare the basic demographic statistics between the cohorts, we used SAS Enterprise Guide to do data preprocessing and statistical analysis. Secondly, we used logistic regression, neural network, decision tree to validate biomarkers by SAS Enterprise Miner. This study generated data from ADNI, contained 146 blood biomarkers from 566 participants. Participants include cognitive normal (healthy), mild cognitive impairment (MCI), and patient suffered Alzheimer’s disease (AD). Participants’ samples were separated into two groups, healthy and MCI, healthy and AD, respectively. We used the two groups to compare important biomarkers of AD and MCI. In preprocessing, we used a t-test to filter 41/47 features between the two groups (healthy and AD, healthy and MCI) before using machine learning algorithms. Then we have built model with 4 machine learning methods, the best AUC of two groups separately are 0.991/0.709. We want to stress the importance that the simple, less invasive, common blood (plasma) test may also early diagnose AD. As our opinion, the result will provide evidence that blood-based biomarkers might be an alternative diagnostics tool before further examination with CSF and medical imaging. A comprehensive study on the differences in blood-based biomarkers between AD patients and healthy subjects is warranted. Early detection of AD progression will allow physicians the opportunity for early intervention and treatment.

Keywords: Alzheimer's disease, blood-based biomarkers, diagnostics, early detection, machine learning

Procedia PDF Downloads 317
2395 Non-Linear Free Vibration Analysis of Laminated Composite Beams Resting on Non-Linear Pasternak Elastic Foundation: A Homogenization Procedure

Authors: Merrimi El Bekkaye, El Bikri Khalid, Benamar Rhali

Abstract:

In the present paper, the problem of geometrically non-linear free vibration of symmetrically and asymmetrically laminated composite beams (LCB) resting on nonlinear Pasternak elastic Foundation with immovable ends is studied. A homogenization procedure has been performed to reduce the problem under consideration to that of the isotropic homogeneous beams with effective bending stiffness and axial stiffness parameters. This simple formulation is developed using the governing axial equation of the beam in which the axial inertia and damping are ignored. The theoretical model is based on Hamilton’s principle and spectral analysis. Iterative form solutions are presented to calculate the fundamental nonlinear frequency parameters which are found to be in a good agreement with the published results. On the other hand, the influence of the foundation parameters on the nonlinear frequency to the linear frequency ratio of the LCB has been studied. The non-dimensional curvatures associated to the fundamental mode are also given in the case of clamped-clamped symmetrically and asymmetrically laminated composite beams.

Keywords: large vibration amplitudes, laminated composite beam, Pasternak foundation, composite beams

Procedia PDF Downloads 526
2394 A Multilevel Approach for Stroke Prediction Combining Risk Factors and Retinal Images

Authors: Jeena R. S., Sukesh Kumar A.

Abstract:

Stroke is one of the major reasons of adult disability and morbidity in many of the developing countries like India. Early diagnosis of stroke is essential for timely prevention and cure. Various conventional statistical methods and computational intelligent models have been developed for predicting the risk and outcome of stroke. This research work focuses on a multilevel approach for predicting the occurrence of stroke based on various risk factors and invasive techniques like retinal imaging. This risk prediction model can aid in clinical decision making and help patients to have an improved and reliable risk prediction.

Keywords: prediction, retinal imaging, risk factors, stroke

Procedia PDF Downloads 295
2393 First Documented Anesthesia with Use of Low Doses of Tiletamine-Zolazepam Combination in Ovoviparous Amazon Tree Boa Undergoing Emergency Coeliotomy-Case Report

Authors: Krzysztof Buczak, Sonia Lachowska, Pawel Kucharski, Agnieszka Antonczyk

Abstract:

Tiletamine - zolazepam combination is increasingly used in veterinary anaesthesiology in wild animals, including snakes. The available literature shows a lack of information about anesthesia in this mixture in ovoviviparous snakes. The studies show the possibility of using the combination at a dose of 20 mg/kg or more for snake immobilization. This paper presents an anesthetic protocol with the use of a combination of tiletamine - zolazepam at the dose of 10 mg/kg intramuscularly and maintenance with inhalant anesthesia with isoflurane in pure oxygen. The objective of this study was to evaluate the usefulness of the anesthetic protocol to proceed with coeliotomy in Amazon Tree Boa. The patient was a five years old bicolor female Amazon Tree Boa (Corallus hortulanus) with dystocia. The clinical examination reveals significant emaciation (bodyweight 520g), high degree of dehydration, heart rate (HR = 60 / min), pale mucous membranes and poor reactivity. Meloxicam (1 mg/kg) and tramadol (10 mg/kg) were administered subcutaneously and the patient was placed in an incubator with access to fresh oxygen. Four hours later, the combination of tiletamine - zolazepam (10 mg/kg) was administered intramuscularly for induction of anesthesia. The snake was intubated and connected to inhalant anesthesia equipment. For maintenance, the anesthesia isoflurane in pure oxygen was used due to apnea, which occurs 30 minutes after the induction semi-closed system was attached and the ventilator was turned on (PCV system, four breaths per minute, 8 cm of H2O). Cardiopulmonary parameters (HR, RR, SPO2, ETCO2, ETISO) were assessed throughout the procedure. During the entire procedure, the operating room was heated to a temperature of 26 degrees Celsius. Additionally, the hose was placed on a heating mat, which maintained a temperature of 30 degrees Celsius. For 15 minutes after induction, the loss of muscle tone was observed from the head to the tail. Induction of general anesthesia was scored as good because of the possibility of intubation. During the whole procedure, the heart rate was at the rate of 58 beats per minute (bpm). Ventilation parameters were stable throughout the procedure. The recovery period lasts for about 4 hours after the end of general anesthesia. The muscle tension returned from tail to head. The snake started to breathe spontaneously within 1,5 hours after the end of general anesthesia. The protocol of general anesthesia with the combination of tiletamine- zolazepam with a dose of 10 mg/kg is useful for proceeding with the emergency coeliotomy in maintenance with isoflurane in oxygen. Further study about the impact of the combination of tiletamine- zolazepam for the recovery period is needed.

Keywords: anesthesia, corallus hortulanus, ovoviparous, snake, tiletamine, zolazepam

Procedia PDF Downloads 238
2392 Some Accuracy Related Aspects in Two-Fluid Hydrodynamic Sub-Grid Modeling of Gas-Solid Riser Flows

Authors: Joseph Mouallem, Seyed Reza Amini Niaki, Norman Chavez-Cussy, Christian Costa Milioli, Fernando Eduardo Milioli

Abstract:

Sub-grid closures for filtered two-fluid models (fTFM) useful in large scale simulations (LSS) of riser flows can be derived from highly resolved simulations (HRS) with microscopic two-fluid modeling (mTFM). Accurate sub-grid closures require accurate mTFM formulations as well as accurate correlation of relevant filtered parameters to suitable independent variables. This article deals with both of those issues. The accuracy of mTFM is touched by assessing the impact of gas sub-grid turbulence over HRS filtered predictions. A gas turbulence alike effect is artificially inserted by means of a stochastic forcing procedure implemented in the physical space over the momentum conservation equation of the gas phase. The correlation issue is touched by introducing a three-filtered variable correlation analysis (three-marker analysis) performed under a variety of different macro-scale conditions typical or risers. While the more elaborated correlation procedure clearly improved accuracy, accounting for gas sub-grid turbulence had no significant impact over predictions.

Keywords: fluidization, gas-particle flow, two-fluid model, sub-grid models, filtered closures

Procedia PDF Downloads 119