Search results for: interior wall area
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 10095

Search results for: interior wall area

10095 A Validated Estimation Method to Predict the Interior Wall of Residential Buildings Based on Easy to Collect Variables

Authors: B. Gepts, E. Meex, E. Nuyts, E. Knaepen, G. Verbeeck

Abstract:

The importance of resource efficiency and environmental impact assessment has raised the interest in knowing the amount of materials used in buildings. If no BIM model or energy performance certificate is available, material quantities can be obtained through an estimation or time-consuming calculation. For the interior wall area, no validated estimation method exists. However, in the case of environmental impact assessment or evaluating the existing building stock as future material banks, knowledge of the material quantities used in interior walls is indispensable. This paper presents a validated method for the estimation of the interior wall area for dwellings based on easy-to-collect building characteristics. A database of 4963 residential buildings spread all over Belgium is used. The data are collected through onsite measurements of the buildings during the construction phase (between mid-2010 and mid-2017). The interior wall area refers to the area of all interior walls in the building, including the inner leaf of exterior (party) walls, minus the area of windows and doors, unless mentioned otherwise. The two predictive modelling techniques used are 1) a (stepwise) linear regression and 2) a decision tree. The best estimation method is selected based on the best R² k-fold (5) fit. The research shows that the building volume is by far the most important variable to estimate the interior wall area. A stepwise regression based on building volume per building, building typology, and type of house provides the best fit, with R² k-fold (5) = 0.88. Although the best R² k-fold value is obtained when the other parameters ‘building typology’ and ‘type of house’ are included, the contribution of these variables can be seen as statistically significant but practically irrelevant. Thus, if these parameters are not available, a simplified estimation method based on only the volume of the building can also be applied (R² k-fold = 0.87). The robustness and precision of the method (output) are validated three times. Firstly, the prediction of the interior wall area is checked by means of alternative calculations of the building volume and of the interior wall area; thus, other definitions are applied to the same data. Secondly, the output is tested on an extension of the database, so it has the same definitions but on other data. Thirdly, the output is checked on an unrelated database with other definitions and other data. The validation of the estimation methods demonstrates that the methods remain accurate when underlying data are changed. The method can support environmental as well as economic dimensions of impact assessment, as it can be used in early design. As it allows the prediction of the amount of interior wall materials to be produced in the future or that might become available after demolition, the presented estimation method can be part of material flow analyses on input and on output.

Keywords: buildings as material banks, building stock, estimation method, interior wall area

Procedia PDF Downloads 0
10094 The Influence of Interior Decoration on Customer's Perception of Hotels in Uyo, Akwa Ibom State Nigeria

Authors: O. B. Enemuo, A. A. Onubuogu

Abstract:

This work evaluated the influence of interior of decoration on customer perception of hotels in Uyo Akwa Ibom State. Specifically the study identified the various interior decoration used in hotels in the study area, determined the interior decoration used in hotels that appeal to the customer more, ascertained the influence of interior decoration on the level of patronage in the hotel in the study area and suggested ways of improving the interior decoration of hotels in the study area for sustainability. The study was guided by four research questions and two hypotheses. It adopted survey research design; structured questionnaire was used for data collection. The samples for the study were four hundred (400) staff and managers from the various hotels in the study area. Data generated were analyzed using mean and standard deviation analyses of variance (ANOVA) derived from regression analyses to test the hypotheses. The result of the finding showed that satisfactory interior decoration has a positive influence on the sustainability of the hospitality establishments in Uyo. The hypothesis showed that there was a significant relationship between the gender perception on the influence of interior decoration in the hotel and significant relationship between the gender perceptions on the influence of interior decoration in the hotels. From the finding, it was recommended that the hotels should design interior decorative service delivery system which has an impact on customer satisfaction in the hospitality industry and practiced healthy decorative environment and increased customer satisfaction.

Keywords: influence, interior decoration, customer’s perception, hotels

Procedia PDF Downloads 276
10093 Hygrothermal Assessment of Internally Insulated Prefabricated Concrete Wall in Polish Climatic Condition

Authors: D. Kaczorek

Abstract:

Internal insulation of external walls is often problematic due to increased moisture content in the wall and interstitial or surface condensation risk. In this paper, the hygrothermal performance of prefabricated, concrete, large panel, external wall typical for WK70 system, commonly used in Poland in the 70’s, with inside, additional insulation was investigated. Thermal insulation board made out of hygroscopic, natural materials with moisture buffer capacity and extruded polystyrene (EPS) board was used as interior insulation. Experience with this natural insulation is rare in Poland. The analysis was performed using WUFI software. First of all, the impact of various standard boundary conditions on the behavior of the different wall assemblies was tested. The comparison of results showed that the moisture class according to the EN ISO 13788 leads to too high values of total moisture content in the wall since the boundary condition according to the EN 15026 should be usually applied. Then, hygrothermal 1D-simulations were conducted by WUFI Pro for analysis of internally added insulation, and the weak point like the joint of the wall with the concrete ceiling was verified using 2D simulations. Results showed that, in the Warsaw climate and the indoor conditions adopted in accordance with EN 15026, in the tested wall assemblies, regardless of the type of interior insulation, there would not be any problems with moisture - inside the structure and on the interior surface.

Keywords: concrete large panel wall, hygrothermal simulation, internal insulation, moisture related issues

Procedia PDF Downloads 153
10092 Investigation of Dynamic Heat Transfer in Masonry Walls

Authors: Joelle Al Fakhoury, Emilio Sassine, Yassine Cherif, Joseph Dgheim, Emmanuel Antczak

Abstract:

Hollow block masonry is the most used building technology in the Lebanese context. These blocks are manufactured in an artisanal way and have unknown thermal properties; their overall thermos-physical performance is thus unknown and also poorly investigated scientifically in both single wall and also double wall configurations. In this work, experimental measurements and numerical simulations are performed for a better understanding of the heat transfer in masonry walls. This study was realized using an experimental setup consisting of a masonry hollow block wall (0.1m x 1m x 1m) and two heat boxes, such that each covers one side of the wall. The first is a reference box having a constant interior temperature, and the other is a control box having an adjustable interior temperature. At first, the numerical model is validated using an experimental setup; then 3D numerical analyzes are held in order to investigate the effect of the air gap, the mortar joints, and the plastering on the thermal performance of masonry walls for a better understanding of the heat transfer process and the recommendation of suitable thermal improvements.

Keywords: masonry wall, hollow blocks, heat transfer, wall instrumentation, thermal improvement

Procedia PDF Downloads 218
10091 Evaluation of Seismic Behavior of Steel Shear Wall with Opening with Hardener and Beam with Reduced Cross Section under Cycle Loading with Finite Element Analysis Method

Authors: Masoud Mahdavi

Abstract:

During an earthquake, the structure is subjected to seismic loads that cause tension in the members of the building. The use of energy dissipation elements in the structure reduces the percentage of seismic forces on the main members of the building (especially the columns). Steel plate shear wall, as one of the most widely used types of energy dissipation element, has evolved today, and regular drilling of its inner plate is one of the common cases. In the present study, using a finite element method, the shear wall of the steel plate is designed as a floor (with dimensions of 447 × 6/246 cm) with Abacus software and in three different modes on which a cyclic load has been applied. The steel shear wall has a horizontal element (beam) with a reduced beam section (RBS). The hole in the interior plate of the models is created in such a way that it has the process of increasing the area, which makes the effect of increasing the surface area of the hole on the seismic performance of the steel shear wall completely clear. In the end, it was found that with increasing the opening level in the steel shear wall (with reduced cross-section beam), total displacement and plastic strain indicators increased, structural capacity and total energy indicators decreased and the Mises Monson stress index did not change much.

Keywords: steel plate shear wall with opening, cyclic loading, reduced cross-section beam, finite element method, Abaqus software

Procedia PDF Downloads 111
10090 Transcending Boundaries: Integrating Urban Vibrancy with Contemporary Interior Design through Vivid Wall Pieces

Authors: B. C. Biermann

Abstract:

This in-depth exploration investigates the transformative integration of urban vibrancy into contemporary interior design through the strategic incorporation of vivid wall pieces. Bridging the gap between public dynamism and private tranquility, this study delves into the nuanced methodologies, creative processes, and profound impacts of this innovative approach. Drawing inspiration from street art's dynamic language and the timeless allure of natural beauty, these artworks serve as conduits, orchestrating a dialogue that challenges traditional boundaries and redefines the relationship between external chaos and internal sanctuaries. The fusion of urban vibrancy with contemporary interior design represents a paradigm shift, where the inherent dynamism of public spaces harmoniously converges with the curated tranquility of private environments. This paper aims to explore the underlying principles, creative processes, and transformative impacts of integrating vivid wall pieces as instruments for bringing the "outside in." Employing an innovative and meticulous methodology, street art elements are synthesized with the refined aesthetics of contemporary design. This delicate balance necessitates a nuanced understanding of both artistic realms, ensuring a synthesis that captures the essence of urban energy while seamlessly blending with the sophistication of modern interior design. The creative process involves a strategic selection of street art motifs, colors, and textures that resonate with the organic beauty found in natural landscapes, creating a symbiotic relationship between the grittiness of the streets and the elegance of interior spaces. This groundbreaking approach defies traditional boundaries by integrating dynamic street art into interior spaces, blurring the demarcation between external chaos and internal tranquility. Vivid wall pieces serve as dynamic focal points, transforming physical spaces and challenging conventional perceptions of where art belongs. This redefinition asserts that boundaries are fluid and meant to be transcended. Case studies illustrate the profound impact of integrating vivid wall pieces on the aesthetic appeal of interior spaces. Urban vibrancy revitalizes the atmosphere, infusing it with palpable energy that resonates with the vivacity of public spaces. The curated tranquility of private interiors coexists harmoniously with the dynamic visual language of street art, fostering a unique and evolving relationship between inhabitants and their living spaces. Emphasizing harmonious coexistence, the paper underscores the potential for a seamless dialogue between public urban spaces and private interiors. The integration of vivid wall pieces acts as a bridge rather than a dichotomy, merging the dynamism of street art with the curated elegance of contemporary design. This unique visual tapestry transcends traditional categorizations, fostering a symbiotic relationship between contrasting worlds. In conclusion, this paper posits that the integration of vivid wall pieces represents a transformative tool for contemporary interior design, challenging and redefining conventional boundaries. By strategically bringing the "outside in," this approach transforms interior spaces and heralds a paradigm shift in the relationship between urban aesthetics and contemporary living. The ongoing narrative between urban vibrancy and interior design creates spaces that reflect the dynamic and ever-evolving nature of the surrounding environment.

Keywords: Art Integration, Contemporary Interior Design, Interior Space Transformation, Vivid Wall Pieces

Procedia PDF Downloads 62
10089 Healing Architecture and Evidence Based Design: An Interior Design Example in Medicana KızıLtoprak Hospital

Authors: Yunus Emre Kara, Atilla Kuzu, Levent Cirpici

Abstract:

Recently, in the interior design of hospitals, the effect of the physical environment on the healing process has been frequently emphasized, and the importance of psychological and behavioral factors has increased day by day. When designing new hospital interiors, it became important to create spaces that not only meet medical requirements but also support the healing process of patients with interior design. In this study, the patient rooms, corridor, atrium area, waiting area, and entrance counter in a hospital were handled with patient-centered design, evidence-based design, and remedial architectural approaches, and it was seen that the healing and reassuring elements in hospitals were extremely important.

Keywords: evidence based design, healing architecture, hospital, organic design, parametric design

Procedia PDF Downloads 171
10088 Re-shaping Ancient Historical Courtyards in a Sustainable Design

Authors: Andreea Anamaria Anghel, Flaviu Mihai Frigura-Lliasa, Attila Simo

Abstract:

In recent years, there has been a renewed interest in revitalizing the historical area of Timisoara, a city located in western Romania, with a focus on preserving its architectural heritage while also promoting sustainable urban development. This has led to several initiatives aimed at improving public spaces, promoting sustainable transport, and encouraging the use of green infrastructure, such as green interior courtyards, to enhance the livability and sustainability of the area. A preliminary study regarding history, characteristics and current condition was carried out by the authors regarding these interior courtyards in the historical areas of Timisoara, the European Capital of Culture, in 2023, highlighting their potential to contribute to the sustainable development of the city. Modern interventions in interior historical courtyards should aim to preserve the historic character of these spaces while also promoting their sustainable and functional use in the 21st century. By doing so, these courtyards can continue to serve as vital urban oases and cultural landmarks for generations to come.

Keywords: architectural heritage, green interior courtyards, public spaces, sustainable development

Procedia PDF Downloads 71
10087 Understanding Seismic Behavior of Masonry Buildings in Earthquake

Authors: Alireza Mirzaee, Soosan Abdollahi, Mohammad Abdollahi

Abstract:

Unreinforced Masonry (URM) wall is vulnerable in resisting horizontal load such as wind and seismic loading. It is due to the low tensile strength of masonry, the mortar connection between the brick units. URM structures are still widely used in the world as an infill wall and commonly constructed with door and window openings. This research aimed to investigate the behavior of URM wall with openings when horizontal load acting on it and developed load-drift relationship of the wall. The finite element (FE) method was chosen to numerically simulate the behavior of URM with openings. In this research, ABAQUS, commercially available FE software with explicit solver was employed. In order to ensure the numerical model can accurately represent the behavior of an URM wall, the model was validated for URM wall without openings using available experimental results. Load-displacement relationship of numerical model is well agreed with experimental results. Evidence shows the same load displacement curve shape obtained from the FE model. After validating the model, parametric study conducted on URM wall with openings to investigate the influence of area of openings and pre-compressive load on the horizontal load capacity of the wall. The result showed that the increasing of area of openings decreases the capacity of the wall in resisting horizontal loading. It is also well observed from the result that capacity of the wall increased with the increasing of pre-compressive load applied on the top of the walls.

Keywords: masonry constructions, performance at earthquake, MSJC-08 (ASD), bearing wall, tie-column

Procedia PDF Downloads 235
10086 The Performance Evaluation of the Modular Design of Hybrid Wall with Surface Heating and Cooling System

Authors: Selcen Nur Eri̇kci̇ Çeli̇k, Burcu İbaş Parlakyildiz, Gülay Zorer Gedi̇k

Abstract:

Reducing the use of mechanical heating and cooling systems in buildings, which accounts for approximately 30-40% of total energy consumption in the world has a major impact in terms of energy conservation. Formations of buildings that have sustainable and low energy utilization, structural elements with mechanical systems should be evaluated with a holistic approach. In point of reduction of building energy consumption ratio, wall elements that are vertical building elements and have an area broadly (m2) have proposed as a regulation with a different system. In the study, designing surface heating and cooling energy with a hybrid type of modular wall system and the integration of building elements will be evaluated. The design of wall element; - Identification of certain standards in terms of architectural design and size, -Elaboration according to the area where the wall elements (interior walls, exterior walls) -Solution of the joints, -Obtaining the surface in terms of building compatible with both conceptual structural put emphasis on upper stages, these elements will be formed. The durability of the product to the various forces, stability and resistance are so much substantial that are used the establishment of ready-wall element section and the planning of structural design. All created ready-wall alternatives will be paid attention at some parameters; such as adapting to performance-cost by optimum level and size that can be easily processed and reached. The restrictions such as the size of the zoning regulations, building function, structural system, wheelbase that are imposed by building laws, should be evaluated. The building aims to intend to function according to a certain standardization system and construction of wall elements will be used. The scope of performance criteria determined on the wall elements, utilization (operation, maintenance) and renovation phase, alternative material options will be evaluated with interim materials located in the contents. Design, implementation and technical combination of modular wall elements in the use phase and installation details together with the integration of energy saving, heat-saving and useful effects on the environmental aspects will be discussed in detail. As a result, the ready-wall product with surface heating and cooling modules will be created and defined as hybrid wall and will be compared with the conventional system in terms of thermal comfort. After preliminary architectural evaluations, certain decisions for all architectural design processes (pre and post design) such as the implementation and performance in use, maintenance, renewal will be evaluated in the results.

Keywords: modular ready-wall element, hybrid, architectural design, thermal comfort, energy saving

Procedia PDF Downloads 240
10085 A Combined CFD Simulation of Plateau Borders including Films and Transitional Areas of Liquid Foams

Authors: Abdolhamid Anazadehsayed, Jamal Naser

Abstract:

An integrated computational fluid dynamics model is developed for a combined simulation of Plateau borders, films, and transitional areas between the film and the Plateau borders to reduce the simplifications and shortcomings of available models for foam drainage in micro-scale. Additionally, the counter-flow related to the Marangoni effect in the transitional area is investigated. The results of this combined model show the contribution of the films, the exterior Plateau borders, and Marangoni flow in the drainage process more accurately since the inter-influence of foam's elements is included in this study. The exterior Plateau borders flow rate can be four times larger than the interior ones. The exterior bubbles can be more prominent in the drainage process in cases where the number of the exterior Plateau borders increases due to the geometry of container. The ratio of the Marangoni counter-flow to the Plateau border flow increases drastically with an increase in the mobility of air-liquid interface. However, the exterior bubbles follow the same trend with much less intensity since typically, the flow is less dependent on the interface of air-liquid in the exterior bubbles. Moreover, the Marangoni counter-flow in a near-wall transition area is less important than an internal one. The influence of air-liquid interface mobility on the average velocity of interior foams is attained with more accuracy with more realistic boundary condition. Then it has been compared with other numerical and analytical results. The contribution of films in the drainage is significant for the mobile foams as the velocity of flow in the film has the same order of magnitude as the velocity in the Plateau border. Nevertheless, for foams with rigid interfaces, film's contribution in foam drainage is insignificant, particularly for the films near the wall of the container.

Keywords: foam, plateau border, film, Marangoni, CFD, bubble

Procedia PDF Downloads 332
10084 Examination of Wall Art in Slums to Prevent Crime Case Study: Jabal Al-Natheef

Authors: Dana Jaber, Lilian Mansor, Lilan Al-Nablsi, Lujain Arabiat, Mariam Attoun

Abstract:

Preventing crime through environmental designs (CPTED) and situational crime prevention methods (SCP) are used to prevent crimes before they occur by anticipating people's actions and behavior in social situations. Many theories focused on wall art in preventing crimes, Graffiti, and situational crime prevention. The main aim of this research is to assess the wall art in slums and how it could avoid crimes by increasing surveillance by studying Jabal Al-Natheef—using a quantitative methodology to study the social life in the site and accumulate the intended actions to prevent crimes by using art. It was shown that the crimes in the area are severe, and they occur in slums due to the bad conditions, maintenance, and lack of surveillance. A finding of how people in the area would react to the art was a positive conclusion to how it could prevent the crimes. The research findings revealed that implementing wall art in slums would decrease the crimes in the area. This research concluded with a proposal to recommend implementing such skills to deter crimes.

Keywords: CPTED, situational crime prevention, wall art, slums

Procedia PDF Downloads 68
10083 Colors and Interiority - A Study on the Relationship of Colors and Interior Spaces

Authors: Mahwish Ghulam Rasool

Abstract:

The design of a space is a complex process that involves multiple stages, from conceptualization, identifying design problems to understanding the context, materiality, and functionality of the space. Out of all the design elements, color is one of the most dominant and expressive factors that affect the spatial dynamics of the interior space. Color affects aesthetic comfort in space and has a lasting impact on human perception and psychology. Using color as a tool for creating spatial experiences is a new paradigm. Color semantics in spaces are not only used for surface treatment or aesthetics, but it also has more powerful functional characteristics. As interior spaces are evolving and becoming experiential with each decade, designers are looking for new processes to enhance the spatial and experiential quality of interior spaces. The relationship between color and interior typologies is a relatively new paradigm. This paper discusses the role of colors in interior spaces from various perspectives, exploring their impact on the formation of interior typologies and the use of colors in space design. The paper analyzes interior typologies worldwide, from residential to commercial interior spaces, where color semantics plays a prominent role in the design. The paper also emphasizes the design process and the creation of design language, unveiling the possibilities of applying colors in interior spaces that can be in harmony with the building context, space functionality, or in opposition to the existing building envelope or environment. The paper aims to contribute to the field of interior design education and practices. By using experimental and various research methodologies for investigation, it aims to fill the gap in the literature regarding color semantics and the relationship between interior typologies.

Keywords: color psychology, color semantics, interior environments, interior typologies

Procedia PDF Downloads 74
10082 Comparative Study of Various Wall Finishes in Buildings in Ondo State, Nigeria

Authors: Ayodele Oluwole Alejo

Abstract:

Wall finishes are the term to describe an application over a wall surface to provide a suitable surface. Wall finishes are smelt, touched and seen by building occupiers even colour and design affects the user psychology and the atmosphere of our building. Building users/owners seem not to recognize the function of various wall finishes in building and factors to be considered in selecting them suitable for the type and purpose of proposed buildings. Therefore, defects such as deterioration, dampness, and stain may occur when comparisons of wall finishes are not made before the selection of appropriate materials at the design stage with knowledge of the various factors that may hinder the performance or maintenance culture of proposed building of a particular location. This research work investigates and compares various wall finishes in building. Buildings in Ondo state, Nigeria were used as the target area to conduct the research works. The factors bearing on various wall finishes were analyzed to find out their individual and collective impact using suitable analytical tools. The findings revealed that paint with high percentage score was the most preferred wall finishes, whereas wall paper was ranked the least by the respondent findings, Factors considered most in the selection of wall finishes was durability with the highest ranking percentage and least was the cost. The study recommends that skilled worker should carry out operations, quality product should be used and all of wall finishes and materials should be considered before selection.

Keywords: building, construction, design, finishes, wall

Procedia PDF Downloads 118
10081 Numerical Simulation of the Coal Spontaneous Combustion Dangerous Area in Composite Long-Wall Gobs

Authors: Changshan Zhang, Zhijin Yu, Shixing Fan

Abstract:

A comprehensive hazard evaluation for coal self-heating in composite long-wall gobs is heavily dependent on computational simulation. In this study, the spatial distributions of cracks which caused significant air leakage were simulated by universal distinct element code (UDEC) simulation. Based on the main routes of air leakage and characteristics of coal self-heating, a computational fluid dynamics (CFD) modeling was conducted to model the coal spontaneous combustion dangerous area in composite long-wall gobs. The results included the oxygen concentration distributions and temperature profiles showed that the numerical approach is validated by comparison with the test data. Furthermore, under the conditions of specific engineering, the major locations where some techniques for extinguishing and preventing long-wall gob fires need to be put into practice were also examined.

Keywords: computational simulation, UDEC simulation, coal self-heating, CFD modeling, long-wall gobs

Procedia PDF Downloads 296
10080 Surveying Coastal Society Perception on Giant Sea Wall Jakarta Development Planning

Authors: Ammar Asfari, Faizah Finur Fithriah, Shighia Ajeng Savitri

Abstract:

Jakarta as the capital city of Indonesia held an important role for the country, that is being the city where central government is located. But its topographic character which categorized as lowland area is causing an ultimate trouble. With average height of 7 meters above the sea level, flood keeps occurring in this city. On the other hand, water exploitation that caused land subsidence and sea-levels increasing by global warming make it even worse. Giant Sea Wall Development is a project created by Jakarta’s government to overcome flood, which is inspired by Saemangeum Dam in South Korea. For further planning, Giant Sea Wall is planned to be water reservoir for Jakarta’s inhabitants. This research’s aim is to fully understand the knowledge and opinion of people living in North Jakarta (Jakarta’s Coastal Area) on Giant Sea Wall development planning using qualitative method analysis with descriptive approach. The result of this research will be one of the determining factors in Giant Sea Wall Jakarta development planning continuance.

Keywords: descriptive approach, Giant Sea Wall Jakarta, qualitative method analysis, society perception

Procedia PDF Downloads 271
10079 Hydraulic Headloss in Plastic Drainage Pipes at Full and Partially Full Flow

Authors: Velitchko G. Tzatchkov, Petronilo E. Cortes-Mejia, J. Manuel Rodriguez-Varela, Jesus Figueroa-Vazquez

Abstract:

Hydraulic headloss, expressed by the values of friction factor f and Manning’s coefficient n, is an important parameter in designing drainage pipes. Their values normally are taken from manufacturer recommendations, many times without sufficient experimental support. To our knowledge, currently there is no standard procedure for hydraulically testing such pipes. As a result of research carried out at the Mexican Institute of Water Technology, a laboratory testing procedure was proposed and applied on 6 and 12 inches diameter polyvinyl chloride (PVC) and high-density dual wall polyethylene pipe (HDPE) drainage pipes. While the PVC pipe is characterized by naturally smooth interior and exterior walls, the dual wall HDPE pipe has corrugated exterior wall and, although considered smooth, a slightly wavy interior wall. The pipes were tested at full and partially full pipe flow conditions. The tests for full pipe flow were carried out on a 31.47 m long pipe at flow velocities between 0.11 and 4.61 m/s. Water was supplied by gravity from a 10 m-high tank in some of the tests, and from a 3.20 m-high tank in the rest of the tests. Pressure was measured independently with piezometer readings and pressure transducers. The flow rate was measured by an ultrasonic meter. For the partially full pipe flow the pipe was placed inside an existing 49.63 m long zero slope (horizontal) channel. The flow depth was measured by piezometers located along the pipe, for flow rates between 2.84 and 35.65 L/s, measured by a rectangular weir. The observed flow profiles were then compared to computer generated theoretical gradually varied flow profiles for different Manning’s n values. It was found that Manning’s n, that normally is assumed constant for a given pipe material, is in fact dependent on flow velocity and pipe diameter for full pipe flow, and on flow depth for partially full pipe flow. Contrary to the expected higher values of n and f for the HDPE pipe, virtually the same values were obtained for the smooth interior wall PVC pipe and the slightly wavy interior wall HDPE pipe. The explanation of this fact was found in Henry Morris’ theory for smooth turbulent conduit flow over isolated roughness elements. Following Morris, three categories of the flow regimes are possible in a rough conduit: isolated roughness (or semi smooth turbulent) flow, wake interference (or hyper turbulent) flow, and skimming (or quasi-smooth) flow. Isolated roughness flow is characterized by friction drag turbulence over the wall between the roughness elements, independent vortex generation, and dissipation around each roughness element. In this regime, the wake and vortex generation zones at each element develop and dissipate before attaining the next element. The longitudinal spacing of the roughness elements and their height are important influencing agents. Given the slightly wavy form of the HDPE pipe interior wall, the flow for this type of pipe belongs to this category. Based on that theory, an equation for the hydraulic friction factor was obtained. The obtained coefficient values are going to be used in the Mexican design standards.

Keywords: drainage plastic pipes, hydraulic headloss, hydraulic friction factor, Manning’s n

Procedia PDF Downloads 264
10078 Wall Shear Stress Under an Impinging Planar Jet Using the Razor Blade Technique

Authors: A. Ritcey, J. R. Mcdermid, S. Ziada

Abstract:

Wall shear stress was experimentally measured under a planar impinging air jet as a function of jet Reynolds number (Rejet = 5000, 8000, 11000) and different normalized impingement distances (H/D = 4, 6, 8, 10, 12) using the razor blade technique to complete a parametric study. The wall pressure, wall pressure gradient, and wall shear stress information were obtained.

Keywords: experimental fluid mechanics, impinging planar jets, skin friction factor, wall shear stress

Procedia PDF Downloads 310
10077 The Effect of Opening on Mode Shapes and Frequencies of Composite Shear Wall

Authors: A. Arabzadeh, H. R. Kazemi Nia Korrani

Abstract:

Composite steel plate shear wall is a lateral loading resistance system, which is used especially in tall buildings. This wall is made of a thin steel plate with reinforced a concrete cover, which is attached to one or both sides of the steel plate. This system is similar to stiffened steel plate shear wall, in which reinforced concrete replaces the steel stiffeners. Composite shear wall have in-plane and out-plane significant strength. Also, they have appropriate ductility. The present numerical investigations were focused on the effects of opening on wall mode shapes. In addition, frequencies of composite shear wall with and without opening are compared. For analyzing composite shear wall, a new program will be developed using of finite element theory and the effects of shape, size and position openings on the behavior of composite shear wall will be studied. Results indicated that the existence of opening decreases wall frequency.

Keywords: composite shear wall, opening, finite element method, modal analysis

Procedia PDF Downloads 520
10076 Structural Analysis and Evolution of 18th Century Ottoman Imperial Mosques (1750-1799) in Comparison with the Classical Period Examples

Authors: U. Demir

Abstract:

18th century which is the period of 'change' in the Ottoman Empire, affects the architecture as well, where the Classical period is left behind, architecture is differentiated in the form language. This change is especially noticeable in monumental buildings and thus manifested itself in the mosques. But, is it possible to talk about the structural context of the 'change' which has been occurred in decoration? The aim of this study is to investigate the changes and classical relations of the 18th century mosques through plan schedules and structure systems. This study focuses on the monumental mosques constructed during the reign of the three sultans who ruled in the second half of the century (Mustafa the 3rd 1757-1774, Abdülhamid the 1st 1774-1789 and Selim the 3rd). According to their construction years these are 'Ayazma, Laleli, Zeyneb Sultan, Fatih, Beylerbeyi, Şebsefa Kadın, Eyüb Sultan, Mihrişah Valide Sultan and Üsküdar-Selimiye' mosques. As a plan scheme, four mosques have a square or close to a rectangular square scheme, while the others have a rectangle scheme and showing the longitudinal development of the mihrab axis. This situation is widespread throughout the period. In addition to the longitudinal development plan, which is the general characteristic of the 18th century mosques, the use of the classical plan schemes continued in the same direction. Spatialization of the mihrab area was applied to the five mosques while other mosques were applied as niches on the wall surface. This situation is widespread in the period of the second half of the century. In the classical period, the lodges may be located at the back of the mosques interior, not interfering with the main worship area. In the period, the lodges were withdrawn from the main worship area. They are separated from the main interior with their own structural and covering systems. The plans seem to be formed as a result of the addition of lodge parts to the northern part of the Classical period mosques. The 18th century mosques are the constructions where the change of the architectural language and style can be observed easily. This change and the break from the classical period manifest themselves quickly in the structural elements, wall surface decorations, pencil work designs, small scale decor elements, motifs. The speed and intensity of change in the decor does not occur the same as in structural context. The mosque construction rules from the traditional and classical era still continues in the century. While some mosque structures have a plan which is inherited from the classical successor, some of were constructed with the same classical period rules. Nonetheless, the location and transformation of the lodges, which are affecting the interior design, are noteworthy. They provide a significant transition on the way to the new language of the mosque design that will be experienced in the next century. It is intended to draw attention to the structural evolution of the 18th century Ottoman architecture through the royal mosques within the scope of this conference.

Keywords: mosque structure, Ottoman architecture, structural evolution, 18th century architecture

Procedia PDF Downloads 183
10075 Congolese Wood in the Antwerp Interwar Interior

Authors: M. Jaenen, M. de Bouw, A. Verdonck, M. Leus

Abstract:

During the interwar period artificial materials were often preferred, but many Antwerp architects relied on the application of wood for most of the interior finishing works and furnishings. Archival, literature and on site research of interwar suburban townhouses and the Belgian wood and furniture industry gave a new insight to the application of wood in the interwar interior. Many interwar designers favored the decorative values in all treatments of wood because of its warmth, comfort, good-wearing, and therefore, economic qualities. For the creation of a successful modern interior the texture and surface of the wood becomes as important as the color itself. This aesthetics valuation was the result of the modernization of the wood industry. The development of veneer and plywood gave the possibility to create strong, flat, long and plain wooden surfaces which are capable of retaining their shape. Also the modernization of cutting machines resulted in high quality and diversity in texture of veneer. The flat and plain plywood surfaces were modern decorated with all kinds of veneer-sliced options. In addition, wood species from the former Belgian Colony Congo were imported. Limba (Terminalia superba), kambala (Chlorophora excelsa), mubala (Pentaclethra macrophylla) and sapelli (Entandrophragma cylindricum) were used in the interior of many Antwerp interwar suburban town houses. From the thirties onwards Belgian wood firms established modern manufactures in Congo. There the local wood was dried, cut and prepared for exportation to the harbor of Antwerp. The presence of all kinds of strong and decorative Congolese wood products supported its application in the interwar interior design. The Antwerp architects combined them in their designs for doors, floors, stairs, built-in-furniture, wall paneling and movable furniture.

Keywords: Antwerp, congo, furniture, interwar

Procedia PDF Downloads 208
10074 Case Study: Hybrid Mechanically Stabilized Earth Wall System Built on Basal Reinforced Raft

Authors: S. Kaymakçı, D. Gündoğdu, H. Özçelik

Abstract:

The truck park of a warehouse for a chain of supermarket was going to be constructed on a poor ground. Rather than using a piled foundation, the client was convinced that a ground improvement using a reinforced foundation raft also known as “basal reinforcement” shall work. The retaining structures supporting the truck park area were designed using a hybrid structure made up of the Terramesh® Wall System and MacGrid™ high strength geogrids. The total wall surface area is nearly 2740 sq.m , reaching a maximum height of 13.00 meters. The area is located in the first degree seismic zone of Turkey and the design seismic acceleration is high. The design of walls has been carried out using pseudo-static method (limit equilibrium) taking into consideration different loading conditions using Eurocode 7. For each standard approach stability analysis in seismic condition were performed. The paper presents the detailed design of the reinforced soil structure, basal reinforcement and the construction methods; advantages of using such system for the project are discussed.

Keywords: basal reinforcement, geogrid, reinforced soil raft, reinforced soil wall, soil reinforcement

Procedia PDF Downloads 290
10073 Dynamic Active Earth Pressure on Flexible Cantilever Retaining Wall

Authors: Snehal R. Pathak, Sachin S. Munnoli

Abstract:

Evaluation of dynamic earth pressure on retaining wall is a topic of primary importance. In present paper, dynamic active earth pressure and displacement of flexible cantilever retaining wall has been evaluated analytically using 2-DOF mass-spring-dashpot model by incorporating both wall and backfill properties. The effect of wall flexibility on dynamic active earth pressure and wall displacement are studied and presented in graphical form. The obtained results are then compared with the various conventional methods, experimental analysis and also with PLAXIS analysis. It is observed that the dynamic active earth pressure decreases with increase in the wall flexibility while wall displacement increases linearly with flexibility of the wall. The results obtained by proposed 2-DOF analytical model are found to be more realistic and economical.

Keywords: earth pressure, earthquake, 2-DOF model, Plaxis, retaining walls, wall movement

Procedia PDF Downloads 520
10072 Studying the Impact of Soil Characteristics in Displacement of Retaining Walls Using Finite Element

Authors: Mojtaba Ahmadabadi, Akbar Masoudi, Morteza Rezai

Abstract:

In this paper, using the finite element method, the effect of soil and wall characteristics was investigated. Thirty and two different models were studied by different parameters. These studies could calculate displacement at any height of the wall for frictional-cohesive soils. The main purpose of this research is to determine the most effective soil characteristics in reducing the wall displacement. Comparing different models showed that the overall increase in internal friction angle, angle of friction between soil and wall and modulus of elasticity reduce the replacement of the wall. In addition, increase in special weight of soil will increase the wall displacement. Based on results, it can be said that all wall displacements were overturning and in the backfill, soil was bulging. Results show that the highest impact is seen in reducing wall displacement, internal friction angle, and the angle friction between soil and wall. One of the advantages of this study is taking into account all the parameters of the soil and walls replacement distribution in wall and backfill soil. In this paper, using the finite element method and considering all parameters of the soil, we investigated the impact of soil parameter in wall displacement. The aim of this study is to provide the best conditions in reducing the wall displacement and displacement wall and soil distribution.

Keywords: retaining wall, fem, soil and wall interaction, angle of internal friction of the soil, wall displacement

Procedia PDF Downloads 377
10071 The Importance of Contemporary Interior Design in today's Day and Age

Authors: Rabab Bamboat, Reenu Singh

Abstract:

Today, contemporary modular interior design components provide us the ease to rethink or change our spaces with flexibility. Specifically, contemporary design is perfect for all those people who feel the need to “change” to feel at home again. The variables such as color, furniture, furnishings, fixtures are some of the elements that are changed and re-furnished at periodic intervals. With contemporary interior design, one can customize the interiors to suit the respective personality and passions. A questionnaire survey was conducted to understand how contemporary interior design and its variables play an important role and should be applied while designing an interior space in today's time. Thus, helping us understand better the needs of people and what they would prefer whilst one keeps practicality and functionality in mind. Based on the analysis and extensive literature review, the study develops an understanding of how contemporary interior design should be applied in today's day and age, making living more practical easy but also stylish. The findings provide a more sustainable, functional, simple, and classy way of living while having customed furniture, color, art in an interior space. These variables provided solutions for effective ideation to support the functionality in a minimal and contemporary interior space. This concludes in providing a better understanding to the designers to incorporate a minimalist or contemporary lifestyle while keeping their requirements and other factors in mind.

Keywords: contemporary, minimal, practicality, personality

Procedia PDF Downloads 161
10070 Effects of Front Porch and Loft on Indoor Ventilation in the Renewal of Beijing Courtyard

Authors: Zhongzhong Zeng, Zichen Liang

Abstract:

In recent years, Beijing courtyards have been facing the problem of renewal and renovation, and the residents are faced with the problems of small house areas, large household sizes, old and dangerous houses, etc. Among the many renovation methods, the authors note two more common practices of using the front porch to expand the floor area and adding a loft. Residents and architects, however, did not give the ventilation performance of the significant interior consideration before beginning the remodeling. The aim of this article is to explore the good or negative impacts of both front porch and loft structures on the manner of interior ventilation in the courtyard. Ventilation, in turn, is crucial to the indoor environmental quality of a home. The major method utilized in this study is the comparative analysis method, in which the authors create four alternative house models with or without a front porch and an attic as two variables and examine internal ventilation using the CFD(Computational Fluid Dynamics) technique. The authors compare the indoor ventilation of four different architectural models with or without front porches and lofts as two variables. The results obtained from the analysis of the sectional airflow and the plane 1.5m height cloud are the existence of the loft, to a certain extent, disrupts the airflow organization of the building and makes the rear wall high windows of the building less effective. Occupying the front porch to become the area of the house has no significant effect on ventilation, but try not to occupy the front porch and add the loft at the same time in the building renovation. The findings of this study led to the following recommendations: strive to preserve the courtyard building's original architectural design and make adjustments to only the inappropriate elements or constructions. The ventilation in the loft portion is inadequate, and the inhabitants typically use the loft as a living area. This may lead to the building relying more on air conditioning in the summer, which would raise energy demand. The front porch serves as a transition place as well as a source of shade, weather protection, and inside ventilation. In conclusion, the examination of interior environments in upcoming studies should concentrate on cross-disciplinary, multi-angle, and multi-level research topics.

Keywords: Beijing courtyard renewal, CFD, indoor environment, ventilation analysis

Procedia PDF Downloads 71
10069 Cultural Transformation in Interior Design in Commercial Space in India

Authors: Siddhi Pedamkar, Reenu Singh

Abstract:

This report is based on how a culture transforms from one era to another era in commercial space. This transformation is observed in commercial as well as residential spaces. The spaces have specific color concepts, surface detailing furniture, and function-specific layouts. But the cultural impact is very rarely seen in commercial spaces, mostly because the interior is divine by function to a large extent. Information was collected from books and research papers. A quantitative survey was conducted to understand people's perceptions about the impact of culture on design entities and how culture dictates the different types of space and their character. The survey also highlights the impact of types of interior lighting, colour schemes, and furniture types on the interior environment. The questionnaire survey helped in framing design parameters for contemporary interior design. The design parameters are used to propose design options for new-age furniture that can be used in co-working spaces. For the new and contemporary working spaces, new age design furniture, interior elements such as visual partition, semi-visual partition, lighting, and layout can be transformed by cultural changes in the working style of people and organization.

Keywords: commercial space, culture, environment, furniture, interior

Procedia PDF Downloads 93
10068 Identification of the Interior Noise Sources of Rail Vehicles

Authors: Hyo-In Koh, Anders Nordborg, Alex Sievi, Chun-Kwon Park

Abstract:

The noise source for the interior room of the high speed train is constituted by the rolling contact between the wheel and the rail, aerodynamic noise and structure-borne sound generated through the vibrations of bogie, connection points to the carbody. Air-borne sound is radiated through the panels and structures into the interior room of the trains. The high-speed lines are constructed with slab track systems and many tunnels. The interior noise level and the frequency characteristics vary according to types of the track structure and the infrastructure. In this paper the main sound sources and the transfer paths are studied to find out the contribution characteristics of the sources to the interior noise of a high-speed rail vehicle. For the identification of the acoustic power of each parts of the rolling noise sources a calculation model of wheel/rail noise is developed and used. For the analysis of the transmission of the sources to the interior noise noise and vibration are measured during the operation of the vehicle. According to operation speeds, the mainly contributed sources and the paths could be analyzed. Results of the calculations on the source generation and the results of the measurement with a high-speed train are shown and discussed.

Keywords: rail vehicle, high-speed, interior noise, noise source

Procedia PDF Downloads 384
10067 Living Wall Systems: An Approach for Reducing Energy Consumption in Curtain Wall Façades

Authors: Salma Maher, Ahmed Elseragy, Sally Eldeeb

Abstract:

Nowadays, Urbanism and climate change lead to the rapid growth in energy consumption and the increase of using air-conditioning for cooling. In a hot climate area, there is a need for a new sustainable alternative that is more convenient for an existing situation. The Building envelope controls the heat transfer between the outside and inside the building. While the building façade is the most critical part, types of façade material play a vital role in influences of the energy demand for heating and cooling due to exposure to direct solar radiation throughout the day. Since the beginning of the twentieth century, the use of curtain walls in office buildings façades started to increase rapidly, which lead to more cooling loads in energy consumption. Integrating the living wall system in urban areas as a sustainable renovation and energy-saving method for the built environment will reduce the energy demand of buildings and will also provide environmental benefits. Also, it will balance the urban ecology and enhance urban life quality. The results show that the living wall systems reduce the internal temperature up to 4.0 °C. This research carries on an analytical study by highlighting the different types of living wall systems and verifying their thermal performance, energy-saving, and life potential on the building. These assessing criteria include the reason for using the Living wall systems in the building façade as well as the effect it has upon the surrounding environment. Finally, the paper ends with concluding the effect of using living wall systems on building. And, it suggests a system as long-lasting, and energy-efficient solution to be applied in curtain wall façades in a hot climate area.

Keywords: living wall systems, energy consumption, curtain walls, energy-saving, sustainability, urban life quality

Procedia PDF Downloads 129
10066 Research on Renovation of Existing Interior Space Based on Post Occupancy Evaluation: A Case Study of the Atrium Space of Zhejiang University Library in Hangzhou

Authors: Qin Dai

Abstract:

The renovation of existing interior space is big issue for architects in today’s China. However the traditional way of space renovation in China mostly focuses on the object itself, and the method also focuses on subjective level without the support of specific data. This research focuses the application of renovation of existing interior space based on post occupancy evaluation by a case study of a typical interior space. The research hopes to give a more scientific method of interior space renovation for architects and help promoting and guiding renovation practice. This research studies the post occupancy evaluation of the atrium space of Zhejiang University Library including subjective satisfaction and physical environmental satisfaction. The result provides necessary data support to conclude the design principles and strategies of renovation. Then the research uses simulation software to verify the availability of the strategy given based on the study. In conclusion, the research summarizes the application process of design methods of renovation of existing interior space based on the post-occupancy evaluation, and testifies to the practical significance of the renovation of existing interior space.

Keywords: existing interior space, physical environmental satisfaction, post occupancy evaluation, renovation of space, subjective satisfaction of space

Procedia PDF Downloads 227