Search results for: Ali Eltayeb Muhsin
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 9

Search results for: Ali Eltayeb Muhsin

9 Design of Reliable and Low Cost Substrate Heater for Thin Film Deposition

Authors: Ali Eltayeb Muhsin, Mohamed Elhadi Elsari

Abstract:

The substrate heater designed for this investigation is a front side substrate heating system. It consists of 10 conventional tungsten halogen lamps and an aluminum reflector, total input electrical power of 5 kW. The substrate is heated by means of a radiation from conventional tungsten halogen lamps directed to the substrate through a glass window. This design allows easy replacement of the lamps and maintenance of the system. Within 2 to 6 minutes the substrate temperature reaches 500 to 830 C by varying the vertical distance between the glass window and the substrate holder. Moreover, the substrate temperature can be easily controlled by controlling the input power to the system. This design gives excellent opportunity to deposit many deferent films at deferent temperatures in the same deposition time. This substrate heater was successfully used for Chemical Vapor Deposition (CVD) of many thin films, such as Silicon, iron, etc.

Keywords: CVD, Halogen Lamp, Substrate Heater, Thin Films.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2690
8 Modal Analysis of Power System with a Microgrid

Authors: Burak Yildirim, Muhsin Tunay Gençoğlu

Abstract:

A microgrid (MG) is a small power grid composed of localized medium or low level power generation, storage systems, and loads. In this paper, the effects of a MG on power systems voltage stability are shown. The MG model, designed to demonstrate the effects of the MG, was applied to the IEEE 14 bus power system which is widely used in power system stability studies. Eigenvalue and modal analysis methods were used in simulation studies. In the study results, it is seen that MGs affect system voltage stability positively by increasing system voltage instability limit value for buses of a power system in which MG are placed.

Keywords: Eigenvalue analysis, microgrid, modal analysis, voltage stability.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1547
7 The Framework of BeeBot: Binus Multi-Client of Intelligent Telepresence Robot

Authors: Widod Budiharto, Muhsin Shodiq, Bayu Kanigoro, Jurike V. Moniaga Hutomo

Abstract:

We present a BeeBot, Binus Multi-client Intelligent Telepresence Robot, a custom-build robot system specifically designed for teleconference with multiple person using omni directional actuator. The robot is controlled using a computer networks, so the manager/supervisor can direct the robot to the intended person to start a discussion/inspection. People tracking and autonomous navigation are intelligent features of this robot. We build a web application for controlling the multi-client telepresence robot and open-source teleconference system used. Experimental result presented and we evaluated its performance.

Keywords: Telepresence robot, robot vision, intelligent robot.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1507
6 Performance Evaluation of Intelligent Controllers for AGC in Thermal Systems

Authors: Muhammad Muhsin, Abhishek Mishra, Shreyansh Vishwakarma, K. Dasaratha Babu, Anudevi Samuel

Abstract:

In an interconnected power system, any sudden small load perturbation in any of the interconnected areas causes the deviation of the area frequencies, the tie line power and voltage deviation at the generator terminals. This paper deals with the study of performance of intelligent Fuzzy Logic controllers coupled with Conventional Controllers (PI and PID) for Load Frequency Control. For analysis, an isolated single area and interconnected two area thermal power systems with and without generation rate constraints (GRC) have been considered. The studies have been performed with conventional PI and PID controllers and their performance has been compared with intelligent fuzzy controllers. It can be demonstrated that these controllers can successfully bring back the excursions in area frequencies and tie line powers within acceptable limits in smaller time periods and with lesser transients as compared to the performance of conventional controllers under same load disturbance conditions. The simulations in MATLAB have been used for comparative studies.

Keywords: Area Control Error, Fuzzy Logic, Generation rate constraint, Load Frequency, Tie line Power.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2368
5 Improving the Compaction Properties and Shear Resistance of Sand Reinforced with COVID-19 Waste Mask Fibers

Authors: Samah Said, Muhsin Elie Rahhal

Abstract:

Due to the COVID-19 pandemic, disposable plastic-based face-masks were excessively used worldwide. Therefore, the production and consumption rates of these masks were significantly brought up, which led to severe environmental problems. The main purpose of this research is to test the possibility of reinforcing soil deposits with mask fibers to reuse pandemic-generated waste materials. When testing the compaction properties, the sand was reinforced with a fiber content that increased from 0% to 0.5%, with successive small increments of 0.1%. The optimum content of 0.1% remarkably increased the maximum dry density of the soil and dropped its optimum moisture content. Added to that, it was noticed that 15 mm and rectangular chips were, respectively, the optimum fiber length and shape to maximize the improvement of the sand compaction properties. Regarding the shear strength, fiber contents of 0.1%, 0.25%, and 0.5% were adopted. The direct shear tests have shown that the highest enhancement was observed for the optimum fiber content of 0.25%. Similar to compaction tests, 15 mm and rectangular chips were respectively the optimum fiber length and shape to extremely enhance the shear resistance of the tested sand.

Keywords: COVID-19, mask fibers, compaction properties, soil reinforcement, shear resistance.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 265
4 Laboratory Investigation of Expansive Soil Stabilized with Calcium Chloride

Authors: Magdi M. E. Zumrawi, Khalid A. Eltayeb

Abstract:

Chemical stabilization is a technique commonly used to improve the expansive soil properties. In this regard, an attempt has been made to evaluate the influence of Calcium Chloride (CaCl2) stabilizer on the engineering properties of expansive soil. A series of laboratory experiments including consistency limits, free swell, compaction, and shear strength tests were performed to investigate the effect of CaCl2 additive with various percentages 0%, 2%, 5%, 10% and 15% for improving expansive soil. The results obtained shows that the increase in the percentage of CaCl2decreased the liquid limit and plasticity index leading to significant reduction in the free swell index. This, in turn, increased the maximum dry density and decreased the optimum moisture content which results in greater strength. The unconfined compressive strength of soil stabilized with 5% CaCl2 increased approximately by 50% as compared to virgin soil. It can be concluded that CaCl2 had shown promising influence on the strength and swelling properties of expansive soil, thereby giving an advantage in improving problematic expansive soil.

Keywords: Calcium chloride, chemical stabilization, expansive soil, improving.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2957
3 Investigation of the Effect of Impulse Voltage to Flashover by Using Water Jet

Authors: Harun Gülan, Muhsin Tunay Gencoglu, Mehmet Cebeci

Abstract:

The main function of the insulators used in high voltage (HV) transmission lines is to insulate the energized conductor from the pole and hence from the ground. However, when the insulators fail to perform this insulation function due to various effects, failures occur. The deterioration of the insulation results either from breakdown or surface flashover. The surface flashover is caused by the layer of pollution that forms conductivity on the surface of the insulator, such as salt, carbonaceous compounds, rain, moisture, fog, dew, industrial pollution and desert dust. The source of the majority of failures and interruptions in HV lines is surface flashover. This threatens the continuity of supply and causes significant economic losses. Pollution flashover in HV insulators is still a serious problem that has not been fully resolved. In this study, a water jet test system has been established in order to investigate the behavior of insulators under dirty conditions and to determine their flashover performance. Flashover behavior of the insulators is examined by applying impulse voltages in the test system. This study aims to investigate the insulator behaviour under high impulse voltages. For this purpose, a water jet test system was installed and experimental results were obtained over a real system and analyzed. By using the water jet test system instead of the actual insulator, the damage to the insulator as a result of the flashover that would occur under impulse voltage was prevented. The results of the test system performed an important role in determining the insulator behavior and provided predictability.

Keywords: Insulator, pollution flashover, high impulse voltage, water jet model.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1184
2 In vitro Susceptibility of Madurella mycetomatis to the Extracts of Anogeissus leiocarpus Leaves

Authors: Ikram Mohamed Eltayeb Elsiddig, Abdel Khalig Muddather, Hiba Abdel Rahman Ali, Saad Mohamed Hussein Ayoub

Abstract:

Anogeissus leiocarpus (Combretaceae) is well known for its medicinal uses in African traditional medicine, for treating many human diseases mainly skin diseases and infections. Mycetoma disease is a fungal and/ or bacterial skininfection, mainly cause by Madurella mycetomatis fungus. This study was carried out in vitro to investigate the antifungal activity of Anogeissus leiocarpus leaf extracts against the isolated pathogenic Madurella mycetomatis, by using the NCCLS modified method compared to Ketoconazole standard drug, and MTT assay. The bioactive fraction was subjected to chemical analysis implementing different chromatographic analytical methods (TLC, HPLC, and LC-MS/MS). The results showed significance antifungal activity of A. leiocarpus leaf extracts against the isolated pathogenic M. mycetomatis, compared to negative and positive controls. The chloroform fraction showed the highest antifungal activity. The chromatographic analysis of the chloroform fraction with the highest activity showed the presence of important bioactive compounds such as ellagic and flavellagic acids derivatives, flavonoids and stilbenoid, which are well known for their antifungal activity.

Keywords: Anogeissus leiocarpus, crude extracts and fractions of Anogeissus leiocarpus, in vitro susceptibility of Madurella mycetomatis, Madurella mycetomatis.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2257
1 Phytochemical Screening, Antioxidant Activity and Lipid Profile Effects of Citrus reticulata Fruit Peel, Zingiber officinale Rhizome and Sesamum indicum Seed Extracts

Authors: Samar Saadeldin Abdelmotalab Omer, Ikram Mohamed Eltayeb Elsiddig, Amna Beshir Medani Ahmed, Saad Mohamed Hussein Ayoub

Abstract:

Many herbal medicinal products are considered potential anti-hypercholesterolemic agents with encouraging safety profiles, however only a limited amount of clinical research exists to support their efficacy. The present study was designed to compare the antihypercholesterolemic and antioxidant activities of the crude ethanolic extracts of Citrus reticulata fruit peel, Zingiber officinale rhizome and Sesamum indicum seeds. Forty-five rats were used throughout the experiment which are extended for four weeks. These were divided into nine groups, five rats per each group as follows; group 1 was the normal control group (rats only fed standard normal rat diet), group 2 was the hypercholesterolemic control group (rats fed only hypercholesterolemic diet which contained 1% cholesterol plus 10% saturated animal fat added to the normal rat diet), groups 3 and 4 were fed hypercholesterolemic diet in addition to Citrus reticulata ethanolic extract at doses of (250mg/kg (group 3) and 500mg/kg (group 4)) administered daily via oral route, groups 5 and 6 were given hypercholesterolemic diet in addition to Zingiber officinale ethanolic extract at doses of (250mg/kg (group 5) and 500mg/kg (group 6)) daily through oral route, groups 7 and 8 fed on hypercholesterolemic diet in addition to Sesamum indicum ethanolic extract at doses of (250mg/kg (group 7) and 500mg/kg (group 8)) daily orally; and group 9 rats were given hypercholesterolemic diet in addition to atorvastatin (0.18mg/kg) daily via oral route as a standard reference antihypercholesterolemic drug. Blood samples from all groups were drawn from the retro-orbital venous plexus four weeks following treatment after overnight fasting and the lipid profile (total cholesterol (TC), high density lipoprotein-cholesterol (HDL-C), low density lipoprotein-cholesterol (LDL-C) and triglyceride levels) were measured and the risk ratio (TC/HDL-C) was assessed. The antioxidant activity of the three plants extracts was determined using DPPH free-radical antioxidant assay. Results of in vivo and in vitro antihypercholesterolemic and antioxidant assay respectively, revealed that the three extracts possess comparable antioxidant and antihypercholesterolemic activities.

Keywords: Antihypercholesterolemic effects, Antioxidant activity, HDL, LDL, TC, TGs, Citrus reticulata, Sesamum indicum, Zingiber officinale.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2629