Search results for: popliteal
10 A Rare Case of Popliteal Artery Aneurysm Presenting with Foot Drop
Authors: John Yahng, Riteesh Bookun
Abstract:
Popliteal artery aneurysms (PAAs) are the most common arterial aneurysm of the periphery. It is defined as focal dilation of the artery more than 50% of the normal vessel diameter which usually varies between 7 mm to 11 mm. The most common presentation for PAAs is claudication due to luminal stenmosis secondary to mural thrombus or acute limb ischaemia due to occlusive thrombosis or distal thromboembolism. It is less common for patients to present with non-ischaemic symptoms secondary to mass effect and compression of adjacent structures, and of these, presentation with common peroneal nerve compression is particularly uncommon. We present a rare case of a 92-year-old female patient presenting with 4-month history of left foot drop with radiological evidence of common peroneal nerve compression secondary to PAA of 22 mm by21mm in size. To the best of our knowledge, this is the smallest reported popliteal aneurysm presenting with foot drop. We also present the endovascular treatment option taken in our case.Keywords: aneurysm, foot drop, peroneal nerve, popliteal
Procedia PDF Downloads 2999 Case Report: A Rare Case of Popliteal Artery Aneurysm Presenting with Foot Drop
Authors: John Yahng, Hansraj Riteesh Bookun
Abstract:
Popliteal artery aneurysms (PAAs) are the most common arterial aneurysm of the periphery. It is defined as focal dilation of the artery more than 50% of the normal vessel diameter which usually varies between 7 mm to 11 mm. The most common presentation for PAAs is claudication due to luminal stenosis secondary to mural thrombus or acute limb ischaemia due to occlusive thrombosis or distal thromboembolism. It is less common for patients to present with non-ischaemic symptoms secondary to mass effect and compression of adjacent structures, and of these, presentation with common peroneal nerve compression is particularly uncommon. We present a rare case of a 92-year-old female patient presenting with 4-month history of left foot drop with radiological evidence of common peroneal nerve compression secondary to PAA of 22 mm by 21mm in size. To the best of our knowledge, this is the smallest reported popliteal aneurysm presenting with foot drop. We also present the endovascular treatment option taken in our case.Keywords: aneurysm, foot drop, peroneal nerve, popliteal
Procedia PDF Downloads 4038 Homing of B Cells via Afferent Lymphatics
Authors: Sara Pereira-Nogueira, Tim Worbs, Marc Permanyer-Bosser, Reinhold Förster
Abstract:
While the entry mechanism of lymphocytes into the lymph node via the blood are well described, it is still largely unknown how cells enter lymph nodes that arrive via afferent lymphatics. In order to address this, our group has established a micro-injection technique in mice through which cells are delivered directly into the lymphatic vessel immediately afferent to the popliteal lymph node. Injected cells can then be tracked via multi-colour fluorescence or 2-photon microscopy, and their localization can be analysed within the popliteal or downstream lymph nodes by immunohistology. Since naïve B cells express the chemokine receptor CXCR5 we intra-lymphatically co-injected B cells derived from wildtype and Cxcr5-deficient mice. While CXCR5 does not play a role in guiding B cells out of the subcapsular sinus, it affects their positioning within the lymph node parenchyma, since CXCR5-deficient B cells are impaired in migrating into the B cell follicle. The knowledge obtained by studying B-cell migration may prove beneficial in clinical settings regarding tumor metastasis or autoimmune diseases.Keywords: afferent lymphatics, B cell migration, chemokine, intra-lymphatic injection
Procedia PDF Downloads 2637 In vitro and in vivo Infectivity of Coxiella burnetii Strains from French Livestock
Authors: Joulié Aurélien, Jourdain Elsa, Bailly Xavier, Gasqui Patrick, Yang Elise, Leblond Agnès, Rousset Elodie, Sidi-Boumedine Karim
Abstract:
Q fever is a worldwide zoonosis caused by the gram-negative obligate intracellular bacterium Coxiella burnetii. Following the recent outbreaks in the Netherlands, a hyper virulent clone was found to be the cause of severe human cases of Q fever. In livestock, Q fever clinical manifestations are mainly abortions. Although the abortion rates differ between ruminant species, C. burnetii’s virulence remains understudied, especially in enzootic areas. In this study, the infectious potential of three C. burnetii isolates collected from French farms of small ruminants were compared to the reference strain Nine Mile (in phase II and in an intermediate phase) using an in vivo (CD1 mice) model. Mice were challenged with 105 live bacteria discriminated by propidium monoazide-qPCR targeting the icd-gene. After footpad inoculation, spleen and popliteal lymph node were harvested at 10 days post-inoculation (p.i). The strain invasiveness in spleen and popliteal nodes was assessed by qPCR assays targeting the icd-gene. Preliminary results showed that the avirulent strains (in phase 2) failed to pass the popliteal barrier and then to colonize the spleen. This model allowed a significant differentiation between strain’s invasiveness on biological host and therefore identifying distinct virulence profiles. In view of these results, we plan to go further by testing fifteen additional C. burnetii isolates from French farms of sheep, goat and cattle by using the above-mentioned in vivo model. All 15 strains display distant MLVA (multiple-locus variable-number of tandem repeat analysis) genotypic profiles. Five of the fifteen isolates will bee also tested in vitro on ovine and bovine macrophage cells. Cells and supernatants will be harvested at day1, day2, day3 and day6 p.i to assess in vitro multiplication kinetics of strains. In conclusion, our findings might help the implementation of surveillance of virulent strains and ultimately allow adapting prophylaxis measures in livestock farms.Keywords: Q fever, invasiveness, ruminant, virulence
Procedia PDF Downloads 3606 Training Volume and Myoelectric Responses of Lower Body Muscles with Differing Foam Rolling Periods
Authors: Humberto Miranda, Haroldo G. Santana, Gabriel A. Paz, Vicente P. Lima, Jeffrey M. Willardson
Abstract:
Foam rolling is a practice that has increased in popularity before and after strength training. The purpose of this study was to compare the acute effects of different foam rolling periods for the lower body muscles on subsequent performance (total repetitions and training volume), myoelectric activity and rating of perceived exertion in trained men. Fourteen trained men (26.2 ± 3.2 years, 178 ± 0.04 cm height, 82.2 ± 10 kg weight and body mass index 25.9 ± 3.3kg/m2) volunteered for this study. Four repetition maximum (4-RM) loads were determined for hexagonal bar deadlift and 45º angled leg press during test and retest sessions over two nonconsecutive days. Five experimental protocols were applied in a randomized design, which included: a traditional protocol (control)—a resistance training session without prior foam rolling; or resistance training sessions performed following one (P1), two (P2), three (P3), or four (P4) sets of 30 sec. foam rolling for the lower extremity musculature. Subjects were asked to roll over the medial and lateral aspects of each muscle group with as much pressure as possible. All foam rolling was completed at a cadence of 50 bpm. These procedures were performed on both sides unilaterally as described below. Quadriceps: between the apex of the patella and the ASIS; Hamstring: between the gluteal fold and popliteal fossa; Triceps surae: between popliteal fossa and calcaneus tendon. The resistance training consisted of five sets with 4-RM loads and two-minute rest intervals between sets, and a four-minute rest interval between the hexagonal bar deadlift and the 45º angled leg press. The number of repetitions completed, the myoelectric activity of vastus lateralis (VL), vastus medialis oblique (VMO), semitendinosus (SM) and medial gastrocnemius (GM) were recorded, as well as the rating of perceived exertion for each protocol. There were no differences between the protocols in the total repetitions for the hexagonal bar deadlift (Control - 16.2 ± 5.9; P1 - 16.9 ± 5.5; P2 - 19.2 ± 5.7; P3 - 19.4 ± 5.2; P4 - 17.2 ± 8.2) (p > 0.05) and 45º angled leg press (Control - 23.3 ± 9.7; P1 - 25.9 ± 9.5; P2 - 29.1 ± 13.8; P3 - 28.0 ± 11.7; P4 - 30.2 ± 11.2) exercises. Similar results between protocols were also noted for myoelectric activity (p > 0.05) and rating of perceived exertion (p > 0.05). Therefore, the results of the present study indicated no deleterious effects on performance, myoelectric activity and rating of perceived exertion responses during lower body resistance training.Keywords: self myofascial release, foam rolling, electromyography, resistance training
Procedia PDF Downloads 2255 Use of a Novel Intermittent Compression Shoe in Reducing Lower Limb Venous Stasis
Authors: Hansraj Riteesh Bookun, Cassandra Monique Hidajat
Abstract:
This pilot study investigated the efficacy of a newly designed shoe which will act as an intermittent pneumatic compression device to augment venous flow in the lower limb. The aim was to assess the degree with which a wearable intermittent compression device can increase the venous flow in the popliteal vein. Background: Deep venous thrombosis and chronic venous insufficiency are relatively common problems with significant morbidity and mortality. While mechanical and chemical thromboprophylaxis measures are in place in hospital environments (in the form of TED stockings, intermittent pneumatic compression devices, analgesia, antiplatelet and anticoagulant agents), there are limited options in a community setting. Additionally, many individuals are poorly tolerant of graduated compression stockings due to the difficulty in putting them on, their constant tightness and increased associated discomfort in warm weather. These factors may hinder the management of their chronic venous insufficiency. Method: The device is lightweight, easy to wear and comfortable, with a self-contained power source. It features a Bluetooth transmitter and can be controlled with a smartphone. It is externally almost indistinguishable from a normal shoe. During activation, two bladders are inflated -one overlying the metatarsal heads and the second at the pedal arch. The resulting cyclical increase in pressure squeezes blood into the deep venous system. This will decrease periods of stasis and potentially reduce the risk of deep venous thrombosis. The shoe was fitted to 2 healthy participants and the peak systolic velocity of flow in the popliteal vein was measured during and prior to intermittent compression phases. Assessments of total flow volume were also performed. All haemodynamic assessments were performed with ultrasound by a licensed sonographer. Results: Mean peak systolic velocity of 3.5 cm/s with standard deviation of 1.3 cm/s were obtained. There was a three fold increase in mean peak systolic velocity and five fold increase in total flow volume. Conclusion: The device augments venous flow in the leg significantly. This may contribute to lowered thromboembolic risk during periods of prolonged travel or immobility. This device may also serve as an adjunct in the treatment of chronic venous insufficiency. The study will be replicated on a larger scale in a multi—centre trial.Keywords: venous, intermittent compression, shoe, wearable device
Procedia PDF Downloads 1944 Lateral Sural Artery Perforators: A Cadaveric Dissection Study to Assess Perforator Surface Anatomy Variability and Average Pedicle Length for Flap Reconstruction
Authors: L. Sun, O. Bloom, K. Anderson
Abstract:
The medial and lateral sural artery perforator flaps (MSAP and LSAP, respectively) are two recently described flaps that are less commonly used in lower limb trauma reconstructive surgeries compared to flaps such as the anterolateral thigh (ALT) flap or the gastrocnemius flap. The LSAP flap has several theoretical benefits over the MSAP, including the ability to be sensate and being more easily manoeuvred into position as a local flap for coverage of lateral knee or leg defects. It is less commonly used in part due to a lack of documented studies of the anatomical reliability of the perforator, and an unquantified average length of the pedicle used for microsurgical anastomosis (if used as a free flap) or flap rotation (if used as a pedicled flap). It has been shown to have significantly lower donor site morbidity compared to other flaps such as the ALT, due to the decreased need for intramuscular dissection and resulting in less muscle loss at the donor site. 11 cadaveric lower limbs were dissected, with a mean of 1.6 perforators per leg, with an average pedicle length of 45mm to the sural artery and 70mm to the popliteal artery. While the majority of perforating arteries lay close to the midline (average of 19mm lateral to the midline), there were patients whose artery was significantly lateral and would have been likely injured by the initial incision during an operation. Adding to the literature base of documented LSAP dissections provides a greater understanding of the anatomical basis of these perforator flaps, and the authors hope this will establish them as a more commonly used and discussed option when managing complicated lower limb trauma requiring soft tissue reconstruction.Keywords: cadaveric, dissection, lateral, perforator flap, sural artery, surface anatomy
Procedia PDF Downloads 1553 The Routine Use of a Negative Pressure Incision Management System in Vascular Surgery: A Case Series
Authors: Hansraj Bookun, Angela Tan, Rachel Xuan, Linheng Zhao, Kejia Wang, Animesh Singla, David Kim, Christopher Loupos
Abstract:
Introduction: Incisional wound complications in vascular surgery patients represent a significant clinical and econometric burden of morbidity and mortality. The objective of this study was to trial the feasibility of applying the Prevena negative pressure incision management system as a routine dressing in patients who had undergone arterial surgery. Conventionally, Prevena has been applied to groin incisions, but this study features applications on multiple wound sites such as the thigh or major amputation stumps. Method: This was a cross-sectional observational, single-centre case series of 12 patients who had undergone major vascular surgery. Their wounds were managed with the Prevena system being applied either intra-operatively or on the first post-operative day. Demographic and operative details were collated as well as the length of stay and complication rates. Results: There were 9 males (75%) with mean age of 66 years and the comorbid burden was as follows: ischaemic heart disease (92%), diabetes (42%), hypertension (100%), stage 4 or greater kidney impairment (17%) and current or ex-smoking (83%). The main indications were acute ischaemia (33%), claudication (25%), and gangrene (17%). There were single instances of an occluded popliteal artery aneurysm, diabetic foot infection, and rest pain. The majority of patients (50%) had hybrid operations with iliofemoral endarterectomies, patch arterioplasties, and further peripheral endovascular treatment. There were 4 complex arterial bypass operations and 2 major amputations. The mean length of stay was 17 ± 10 days, with a range of 4 to 35 days. A single complication, in the form of a lymphocoele, was encountered in the context of an iliofemoral endarterectomy and patch arterioplasty. This was managed conservatively. There were no deaths. Discussion: The Prevena wound management system shows that in conjunction with safe vascular surgery, absolute wound complication rates remain low and that it remains a valuable adjunct in the treatment of vasculopaths.Keywords: wound care, negative pressure, vascular surgery, closed incision
Procedia PDF Downloads 1362 Total Arterial Coronary Revascularization with Aorto-Bifemoral Bipopliteal Bypass: A Case Report
Authors: Nuruddin Mohammod Zahangir, Syed Tanvir Ahmady, Firoz Ahmed, Mainul Kabir, Tamjid Mohammad Najmus Sakib Khan, Nazmul Hossain, Niaz Ahmed, Madhava Janardhan Naik
Abstract:
The management of combined Coronary Artery Disease and Peripheral Vascular Disease is a challenge and brings with it numerous clinical dilemmas.The 56 year old gentleman presented to our department with significant triple vessel disease with occluded lower end of aorta just before bifurcation and bilateral superficial femoral arteries. Operation was done on 11.03.14. The The Left Internal Mammary Artery (LIMA) and the Right Internal Mammary Artery (RIMA) were harvested in skeletonized manner. The free RIMA was then anastomosed with LIMA to make LIMA-RIMA Y. Cardio Pulmonary Bypass was then established and coronary artery bypass grafts performed. LIMA was anastomosed to the Left Anterior Descending artery. RIMA was anastomosed to Posterior Descending Artery, 1st and 2nd Obtuse Marginal arteries in a sequential manner. Abdomen was opened by midline incision. The infrarenal aorta exposed and was found to be severely diseased. A Vascular Clamp was applied infrarenally, aortotomy done and limited endarterectomy performed. An end-to-side anastomosis was done with upper end of PTFE synthetic Y-graft (14/7 mm) to the infarenal Aorta and the Clamp released. Good flow noted in both limbs of the graft. Patient was then slowly weaned off from Cardio Pulmonary Bypass without difficulty. The distal two limbs of the Y graft were passed to the groin through retroperitoneal tunnels and anastomosed end-to-side with the common femoral arteries. Saphenous vein was interposed between common femoral and popliteal arteries bilaterally through subfascial tunnels in both thigh. On 12th postoperative day he was discharged from hospital in good general condition. Follow up after 3 months of operation the patient is doing good and free of chest pain and claudication pain.Keywords: total arterial, coronary revascularization, aorto-bifemoral bypass, bifemoro-bipopliteal bypass
Procedia PDF Downloads 4721 Angiopermissive Foamed and Fibrillar Scaffolds for Vascular Graft Applications
Authors: Deon Bezuidenhout
Abstract:
Pre-seeding with autologous endothelial cells improves the long-term patency of synthetic vascular grafts levels obtained with autografts, but is limited to a single centre due to resource, time and other constraints. Spontaneous in vivo endothelialization would obviate the need for pre-seeding, but has been shown to be absent in man due to limited transanastomotic and fallout healing, and the lack of transmural ingrowth due to insufficient porosity. Two types of graft scaffolds with increased interconnected porosity for improved tissue ingrowth and healing are thus proposed and described. Foam-type polyurethane (PU) scaffolds with small, medium and large, interconnected pores were made by phase inversion and spherical porogen extraction, with and without additional surface modification with covalently attached heparin and subsequent loading with and delivery of growth factors. Fibrillar scaffolds were made either by standard electrospinning using degradable PU (Degrapol®), or by dual electrospinning using non-degradable PU. The latter process involves sacrificial fibres that are co-spun with structural fibres and subsequently removed to increased porosity and pore size. Degrapol samples were subjected to in vitro degradation, and all scaffold types were evaluated in vivo for tissue ingrowth and vascularization using rat subcutaneous model. The foam scaffolds were additionally evaluated in a circulatory (rat infrarenal aortic interposition) model that allows for the grafts to be anastomotically and/or ablumenally isolated to discern and determine endothelialization mode. Foam-type grafts with large (150 µm) pores showed improved subcutaneous healing in terms of vascularization and inflammatory response over smaller pore sizes (60 and 90µm), and vascularization of the large porosity scaffolds was significantly increased by more than 70% by heparin modification alone, and by 150% to 400% when combined with growth factors. In the circulatory model, extensive transmural endothelialization (95±10% at 12 w) was achieved. Fallout healing was shown to be sporadic and limited in groups that were ablumenally isolated to prevent transmural ingrowth (16±30% wrapped vs. 80±20% control; p<0.002). Heparinization and GF delivery improved both mural vascularization and lumenal endothelialization. Degrapol electrospun scaffolds showed decrease in molecular mass and corresponding tensile strength over the first 2 weeks, but very little decrease in mass over the 4w test period. Studies on the effect of tissue ingrowth with and without concomitant degradation of the scaffolds, are being used to develop material models for the finite element modelling. In the case of the dual-spun scaffolds, the PU fibre fraction could be controlled shown to vary linearly with porosity (P = −0.18FF +93.5, r2=0.91), which in turn showed inverse linear correlation with tensile strength and elastic modulus (r2 > 0.96). Calculated compliance and burst pressures of the scaffolds increased with fibre fraction, and compliances matching the human popliteal artery (5-10 %/100 mmHg), and high burst pressures (> 2000 mmHg) could be achieved. Increasing porosity (76 to 82 and 90%) resulted in increased tissue ingrowth from 33±7 to 77±20 and 98±1% after 28d. Transmural endothelialization of highly porous foamed grafts is achievable in a circulatory model, and the enhancement of porosity and tissue ingrowth may hold the key the development of spontaneously endothelializing electrospun grafts.Keywords: electrospinning, endothelialization, porosity, scaffold, vascular graft
Procedia PDF Downloads 296