Search results for: orthotics
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 8

Search results for: orthotics

8 The Low-Cost Design and 3D Printing of Structural Knee Orthotics for Athletic Knee Injury Patients

Authors: Alexander Hendricks, Sean Nevin, Clayton Wikoff, Melissa Dougherty, Jacob Orlita, Rafiqul Noorani

Abstract:

Knee orthotics play an important role in aiding in the recovery of those with knee injuries, especially athletes. However, structural knee orthotics is often very expensive, ranging between $300 and $800. The primary reason for this project was to answer the question: can 3D printed orthotics represent a viable and cost-effective alternative to present structural knee orthotics? The primary objective for this research project was to design a knee orthotic for athletes with knee injuries for a low-cost under $100 and evaluate its effectiveness. The initial design for the orthotic was done in SolidWorks, a computer-aided design (CAD) software available at Loyola Marymount University. After this design was completed, finite element analysis (FEA) was utilized to understand how normal stresses placed upon the knee affected the orthotic. The knee orthotic was then adjusted and redesigned to meet a specified factor-of-safety of 3.25 based on the data gathered during FEA and literature sources. Once the FEA was completed and the orthotic was redesigned based from the data gathered, the next step was to move on to 3D-printing the first design of the knee brace. Subsequently, physical therapy movement trials were used to evaluate physical performance. Using the data from these movement trials, the CAD design of the brace was refined to accommodate the design requirements. The final goal of this research means to explore the possibility of replacing high-cost, outsourced knee orthotics with a readily available low-cost alternative.

Keywords: 3D printing, knee orthotics, finite element analysis, design for additive manufacturing

Procedia PDF Downloads 150
7 Teaching Prosthetic and Orthotics in Palestine: Between Reality and Challenges

Authors: Ahmad Dawabsheh

Abstract:

The science of prosthetics is a renewable science that serves all humanity, regardless of gender, religion and race, and its causes are many: wars, conflicts, traffic accidents, and others. The researcher believes that there are challenges facing the specialization, including that society views a negative view of the amputee, especially if it is a female. This research aims to focus on the reality of teaching prosthetics in Palestine, especially in the Arab American University, as it is the only major. As well as the challenges facing this major: financial, human, academic, laboratories, and others. The researcher used the descriptive and analytical approach, which is the closest approach to studying the subject. The researcher believes that there is a failure on the part of the state and the Ministry of Health in this matter. In addition to the lack of societal culture, as well as the large quantities of prosthetic fittings.

Keywords: prothetics, orthotics, Arab American University, Palestine

Procedia PDF Downloads 105
6 3D Design of Orthotic Braces and Casts in Medical Applications Using Microsoft Kinect Sensor

Authors: Sanjana S. Mallya, Roshan Arvind Sivakumar

Abstract:

Orthotics is the branch of medicine that deals with the provision and use of artificial casts or braces to alter the biomechanical structure of the limb and provide support for the limb. Custom-made orthoses provide more comfort and can correct issues better than those available over-the-counter. However, they are expensive and require intricate modelling of the limb. Traditional methods of modelling involve creating a plaster of Paris mould of the limb. Lately, CAD/CAM and 3D printing processes have improved the accuracy and reduced the production time. Ordinarily, digital cameras are used to capture the features of the limb from different views to create a 3D model. We propose a system to model the limb using Microsoft Kinect2 sensor. The Kinect can capture RGB and depth frames simultaneously up to 30 fps with sufficient accuracy. The region of interest is captured from three views, each shifted by 90 degrees. The RGB and depth data are fused into a single RGB-D frame. The resolution of the RGB frame is 1920px x 1080px while the resolution of the Depth frame is 512px x 424px. As the resolution of the frames is not equal, RGB pixels are mapped onto the Depth pixels to make sure data is not lost even if the resolution is lower. The resulting RGB-D frames are collected and using the depth coordinates, a three dimensional point cloud is generated for each view of the Kinect sensor. A common reference system was developed to merge the individual point clouds from the Kinect sensors. The reference system consisted of 8 coloured cubes, connected by rods to form a skeleton-cube with the coloured cubes at the corners. For each Kinect, the region of interest is the square formed by the centres of the four cubes facing the Kinect. The point clouds are merged by considering one of the cubes as the origin of a reference system. Depending on the relative distance from each cube, the three dimensional coordinate points from each point cloud is aligned to the reference frame to give a complete point cloud. The RGB data is used to correct for any errors in depth data for the point cloud. A triangular mesh is generated from the point cloud by applying Delaunay triangulation which generates the rough surface of the limb. This technique forms an approximation of the surface of the limb. The mesh is smoothened to obtain a smooth outer layer to give an accurate model of the limb. The model of the limb is used as a base for designing the custom orthotic brace or cast. It is transferred to a CAD/CAM design file to design of the brace above the surface of the limb. The proposed system would be more cost effective than current systems that use MRI or CT scans for generating 3D models and would be quicker than using traditional plaster of Paris cast modelling and the overall setup time is also low. Preliminary results indicate that the accuracy of the Kinect2 is satisfactory to perform modelling.

Keywords: 3d scanning, mesh generation, Microsoft kinect, orthotics, registration

Procedia PDF Downloads 164
5 A Smart CAD Program for Custom Hand Orthosis Generation Based on Anthropometric Relationships

Authors: Elissa D. Ledoux, Eric J. Barth

Abstract:

Producing custom orthotic devices is a time-consuming and iterative process. Efficiency could be increased with a smart CAD program to rapidly generate custom part files for 3D printing, reducing the need for a skilled orthosis technician as well as the hands-on time required. Anthropometric data for the hand was analyzed in order to determine dimensional relationships and reduce the number of measurements needed to parameterize the hand. Using these relationships, a smart CAD package was developed to produce custom sized hand orthosis parts downloadable for 3D printing. Results showed that the number of anatomical parameters required could be reduced from 8 to 3, and the relationships hold for 5th to 95th percentile male hands. CAD parts regenerate correctly for the same range. This package could significantly impact the orthotics industry in terms of expedited production and reduction of required human resources and patient contact.

Keywords: CAD, hand, orthosis, orthotic, rehabilitation robotics, upper limb

Procedia PDF Downloads 193
4 Influence of Hearing Aids on Non-medically Treatable Deafness

Authors: Donatien Niragira

Abstract:

The progress of technology creates new expectations for patients. The world of deafness is no exception. In recent years, there have been considerable advances in the field of technologies aimed at assisting failing hearing. According to the usual medical vocabulary, hearing aids are actually orthotics. They do not replace an organ but compensate for a functional impairment. The Amplifier Hearing amplification is useful for a large number of people with hearing loss. Hearing aids restore speech audibility. However, their benefits vary depending on the quality of residual hearing. The hearing aid is not a "cure" for deafness. It cannot correct all affected hearing abilities. It should be considered as an aid to communication. The urge to judge from the audiogram alone should be resisted here, as audiometry only indicates the ability to detect non-verbal sounds. To prevent hearing aids from ending up in the drawer, it is important to ensure that the patient's disability situations justify the use of this type of orthosis. If the problems of receptive Pre-fitting counseling are crucial: the person with hearing loss must be informed of the advantages and disadvantages of amplification in his or her case. Their expectations must be realistic. They also need to be aware that the adaptation process requires a good deal of patience and perseverance. They should be informed about the various models and types of hearing aids, including all the aesthetic, functional and financial considerations. If the person's motivation "survives" pre-fitting counseling, we are in the presence of a good candidate for amplification. In addition to its relevance, it shows that the results found in this study significantly improve the quality of audibility in the patient, from where this technology must be made accessible everywhere in the world.

Keywords: auditives protheses, hearing, aids, no medicaly treatable deafnes

Procedia PDF Downloads 26
3 Influence of Hearing Aids on Non-Medically Treatable Deafness

Authors: Niragira Donatien

Abstract:

The progress of technology creates new expectations for patients. The world of deafness is no exception. In recent years, there have been considerable advances in the field of technologies aimed at assisting failing hearing. According to the usual medical vocabulary, hearing aids are actually orthotics. They do not replace an organ but compensate for a functional impairment. The amplifier hearing amplification is useful for a large number of people with hearing loss. Hearing aids restore speech audibility. However, their benefits vary depending on the quality of residual hearing. The hearing aid is not a "cure" for deafness. It cannot correct all affected hearing abilities. It should be considered as an aid to communicate who the best candidates for hearing aids are. The urge to judge from the audiogram alone should be resisted here, as audiometry only indicates the ability to detect non-verbal sounds. To prevent hearing aids from ending up in the drawer, it is important to ensure that the patient's disability situations justify the use of this type of orthosis. If the problems of receptive pre-fitting counselling are crucial, the person with hearing loss must be informed of the advantages and disadvantages of amplification in his or her case. Their expectations must be realistic. They also need to be aware that the adaptation process requires a good deal of patience and perseverance. They should be informed about the various models and types of hearing aids, including all the aesthetic, functional, and financial considerations. If the person's motivation "survives" pre-fitting counselling, we are in the presence of a good candidate for amplification. In addition to its relevance, hearing aids raise other questions: Should one or both ears be fitted? In short, all these questions show that the results found in this study significantly improve the quality of audibility in the patient, from where this technology must be made accessible everywhere in the world. So we want to progress with the technology.

Keywords: audiology, influence, hearing, madicaly, treatable

Procedia PDF Downloads 25
2 Epidemiological Analysis of the Patients Supplied with Foot Orthoses in Ortho-Prosthetic Center of Kosovo

Authors: Ardiana Murtezani, Ilirijana Dallku, Teuta Osmani Vllasolli, Sabit Sllamniku

Abstract:

Background: The use of foot orthoses are always indicated when there are alterations of the optimal biomechanics' position of the foot. Orthotics are very effective and very suitable for the majority of patients with pain due to overload which can be related to biomechanical disorders. Aim: To assess the frequency of patients requiring foot orthoses, type of orthoses and analysis of their disease leading to the use of foot orthoses. Material and Methods: Our study included 128 patients with various foot pathologies, treated at the outpatient department of the Ortho-Prosthetic Center of Kosovo (OPCK) in Prishtina. Prospective-descriptive clinical method was used during this study. Functional status of patients was examined, and the following parameters are noted: range of motion measurements for the affected joints/lower extremities, manual test for muscular strength below the knee and foot of the affected extremity, perimeter measurements of the lower extremities, measurements of lower extremities, foot length measurement, foot width measurements and size. In order to complete the measurements the following instruments are used: plantogram, pedogram, meter and cork shoe lift appliances. Results: The majority of subjects in this study are male (60.2% vs. 39.8%), and the dominant age group was 0-9 (47.7%), 61 subjects respectively. Most frequent foot disorders were: congenital disease 60.1%, trauma cases 13.3%, consequences from rheumatologic disease 12.5%, neurologic dysfunctions 11.7%, and the less frequented are the infectious cases 1.6%. Congenital anomalies were the most frequent cases, and from this group majority of cases suffered from pes planovalgus (37.5%), eqinovarus (15.6%) and discrepancies between extremities (6.3%). Furthermore, traumatic amputations (2.3%) and arthritis (0.8%). As far as neurologic disease, subjects with cerebral palsy are represented with (3.1%), peroneal nerve palsy (2.3%) and hemiparesis (1.6%). Infectious disease osteomyelitis sequels are represented with (1.6%). Conclusion: Based on our study results, we have concluded that the use of foot orthoses for patients suffering from rheumatoid arthritis and nonspecific arthropaty was effective treatment choice, leading to decrease of pain, less deformities and improves the quality of life.

Keywords: orthoses, epidemiological analysis, rheumatoid arthritis, rehabilitation

Procedia PDF Downloads 205
1 Characterizing the Rectification Process for Designing Scoliosis Braces: Towards Digital Brace Design

Authors: Inigo Sanz-Pena, Shanika Arachchi, Dilani Dhammika, Sanjaya Mallikarachchi, Jeewantha S. Bandula, Alison H. McGregor, Nicolas Newell

Abstract:

The use of orthotic braces for adolescent idiopathic scoliosis (AIS) patients is the most common non-surgical treatment to prevent deformity progression. The traditional method to create an orthotic brace involves casting the patient’s torso to obtain a representative geometry, which is then rectified by an orthotist to the desired geometry of the brace. Recent improvements in 3D scanning technologies, rectification software, CNC, and additive manufacturing processes have given the possibility to compliment, or in some cases, replace manual methods with digital approaches. However, the rectification process remains dependent on the orthotist’s skills. Therefore, the rectification process needs to be carefully characterized to ensure that braces designed through a digital workflow are as efficient as those created using a manual process. The aim of this study is to compare 3D scans of patients with AIS against 3D scans of both pre- and post-rectified casts that have been manually shaped by an orthotist. Six AIS patients were recruited from the Ragama Rehabilitation Clinic, Colombo, Sri Lanka. All patients were between 10 and 15 years old, were skeletally immature (Risser grade 0-3), and had Cobb angles between 20-45°. Seven spherical markers were placed at key anatomical locations on each patient’s torso and on the pre- and post-rectified molds so that distances could be reliably measured. 3D scans were obtained of 1) the patient’s torso and pelvis, 2) the patient’s pre-rectification plaster mold, and 3) the patient’s post-rectification plaster mold using a Structure Sensor Mark II 3D scanner (Occipital Inc., USA). 3D stick body models were created for each scan to represent the distances between anatomical landmarks. The 3D stick models were used to analyze the changes in position and orientation of the anatomical landmarks between scans using Blender open-source software. 3D Surface deviation maps represented volume differences between the scans using CloudCompare open-source software. The 3D stick body models showed changes in the position and orientation of thorax anatomical landmarks between the patient and the post-rectification scans for all patients. Anatomical landmark position and volume differences were seen between 3D scans of the patient’s torsos and the pre-rectified molds. Between the pre- and post-rectified molds, material removal was consistently seen on the anterior side of the thorax and the lateral areas below the ribcage. Volume differences were seen in areas where the orthotist planned to place pressure pads (usually at the trochanter on the side to which the lumbar curve was tilted (trochanter pad), at the lumbar apical vertebra (lumbar pad), on the rib connected to the apical vertebrae at the mid-axillary line (thoracic pad), and on the ribs corresponding to the upper thoracic vertebra (axillary extension pad)). The rectification process requires the skill and experience of an orthotist; however, this study demonstrates that the brace shape, location, and volume of material removed from the pre-rectification mold can be characterized and quantified. Results from this study can be fed into software that can accelerate the brace design process and make steps towards the automated digital rectification process.

Keywords: additive manufacturing, orthotics, scoliosis brace design, sculpting software, spinal deformity

Procedia PDF Downloads 121