Search results for: forceps
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 11

Search results for: forceps

11 Mini-Open Repair Using Ring Forceps Show Similar Results to Repair Using Achillon Device in Acute Achilles Tendon Rupture

Authors: Chul Hyun Park

Abstract:

Background:Repair using the Achillon deviceis a representative mini-open repair technique;however, the limitations of this technique includethe need for special instruments and decreasedrepair strength.A modifiedmini-open repair using ring forcepsmight overcome these limitations. Purpose:This study was performed to compare the Achillon device with ring forceps in mini-open repairsof acute Achilles tendon rupture. Study Design:This was a retrospective cohort study, and the level of evidence was3. Methods:Fifty patients (41 men and 9 women), withacute Achilles tendon rupture on one foot, were consecutively treated using mini-open repair techniques. The first 20 patients were treated using the Achillon device (Achillon group) and the subsequent 30 patients were treated using a ring forceps (Forcep group). Clinical, functional, and isokinetic results,and postoperative complications were compared between the two groups at the last follow-up. Clinical evaluations wereperformed using the American Orthopedic Foot and Ankle Society (AOFAS) score, Achilles tendon Total Rupture Score (ATRS), length of incision, and operation time. Functional evaluationsincludedactive range of motion (ROM) of the ankle joint, maximum calf circumference (MCC), hopping test, and single limb heel-rise (SLHR) test. Isokinetic evaluations were performed using the isokinetic test for ankle plantar flexion. Results:The AOFAS score (p=0.669), ATRS (p=0.753), and length of incision (p=0.305) were not significantly different between the groups. Operative times in the Achillon group were significantly shorter than that in the Forcep group (p<0.001).The maximum height of SLHR (p=0.023) and number of SLHRs (p=0.045) in the Forcep group were significantly greater than that in the Achillon group. No significant differences in the mean peak torques for plantar flexion at angular speeds of 30°/s (p=0.219) and 120°/s (p=0.656) were detected between the groups. There was no significant difference in the occurrence of postoperative complications between the groups (p=0.093). Conclusion:The ring forceps technique is comparable with the Achillon technique with respect to clinical, functional, and isokinetic results and the postoperative complications. Given that no special instrument is required, the ring forceps technique could be a better option for acute Achilles tendon rupture repair.

Keywords: achilles tendon, acute rupture, repair, mini-open

Procedia PDF Downloads 51
10 Risk Factors for Significant Obstetric Anal Sphincter Injury in a District General Hospital

Authors: A. Wahid Uddin

Abstract:

Obstetric anal sphincter injury carries significant morbidity for a woman and affects the quality of life to the extent of permanent damage to anal sphincter musculature. The study was undertaken in a district general hospital by retrospectively reviewing random 63 case notes of patients diagnosed with a significant third or fourth-degree perineal tear admitted between the year of 2015 to 2018. The observations were collected by a pre-designed questionnaire. All variables were expressed as percentages. The major risk factors noted were nulliparity (37%), instrumental delivery (25%), and birth weight of more than 4 kg (14%). Forceps delivery with or without episiotomy was the major contributing factor (75%). In the majority of the cases (71%), no record of any perineal protection measures undertaken. The study concluded that recommended perineal protection measures should be adopted as a routine practise.

Keywords: forceps, obstetrics, perineal, sphincter

Procedia PDF Downloads 100
9 Development of a Real-Time Simulink Based Robotic System to Study Force Feedback Mechanism during Instrument-Object Interaction

Authors: Jaydip M. Desai, Antonio Valdevit, Arthur Ritter

Abstract:

Robotic surgery is used to enhance minimally invasive surgical procedure. It provides greater degree of freedom for surgical tools but lacks of haptic feedback system to provide sense of touch to the surgeon. Surgical robots work on master-slave operation, where user is a master and robotic arms are the slaves. Current, surgical robots provide precise control of the surgical tools, but heavily rely on visual feedback, which sometimes cause damage to the inner organs. The goal of this research was to design and develop a real-time simulink based robotic system to study force feedback mechanism during instrument-object interaction. Setup includes three Velmex XSlide assembly (XYZ Stage) for three dimensional movement, an end effector assembly for forceps, electronic circuit for four strain gages, two Novint Falcon 3D gaming controllers, microcontroller board with linear actuators, MATLAB and Simulink toolboxes. Strain gages were calibrated using Imada Digital Force Gauge device and tested with a hard-core wire to measure instrument-object interaction in the range of 0-35N. Designed simulink model successfully acquires 3D coordinates from two Novint Falcon controllers and transfer coordinates to the XYZ stage and forceps. Simulink model also reads strain gages signal through 10-bit analog to digital converter resolution of a microcontroller assembly in real time, converts voltage into force and feedback the output signals to the Novint Falcon controller for force feedback mechanism. Experimental setup allows user to change forward kinematics algorithms to achieve the best-desired movement of the XYZ stage and forceps. This project combines haptic technology with surgical robot to provide sense of touch to the user controlling forceps through machine-computer interface.

Keywords: surgical robot, haptic feedback, MATLAB, strain gage, simulink

Procedia PDF Downloads 496
8 A New Manoeuvre for Prevention of Post-Partum Haemorrhage

Authors: Amr Hamdy

Abstract:

Background: Postpartum haemorrhage (PPH) is the leading cause of maternal mortality worldwide. Many methods have been developed to decrease its rate. The aim of this study was to evaluate the applicability of a new non-pharmacologic maneuver in decreasing its rate. Methods: This case series study was conducted in one centre in Cairo, Egypt, from January-2010 to June-2013. 400 pregnant–women aged 18 years or more and candidate for normal labour; were enrolled to this study. High-risk subjects for PPH were excluded. After placental delivery, the new maneuver was done by sustained traction of the anterior and posterior lips of the cervix by two ovum forceps for duration of 90 seconds. The amount of blood loss was estimated by standardized visual estimation after removal of the forceps. All subjects were followed up for 6 hours. Results: The rate of PPH, defined as more than 500 ml, was 8 cases (2%) with 95% CI (0.63-3.37%). The rate of PPH was not affected by parity, gestational age, episiotomy or the presence of tears. PPH is more in cases with anemia (p 0.032). It occurred in all cases with uterine atony (p <0.001). The range of estimated blood loss was 550-600ml in cases with PPH and 150-450ml in cases without PPH. Severe PPH more than 1000 ml, did not occur. Conclusion: This pilot study introduced a novel maneuver that can be helpful in decreasing the rate of PPH and reducing the amount of post partum blood loss.Despite the low rate of PPH showed in this study, the need for conducting a randomized controlled study is at its highest level before further inclusion of such manoeuvre to be a part of the current medical practice and before considering it as an evident tool to decrease the burden of PPH.

Keywords: maternal mortality, new manoeuvre, post-partum haemorrhage, uterine atony

Procedia PDF Downloads 157
7 Men’s Attendance in Labour and Birth Room: A Choice and Coercion in Childbirth

Authors: A/Prof Marjan Khajehei

Abstract:

In the last century, the role of fathers in the birth has changed exponentially. Before the 1970s, the principal view was that birth was a female business and not a man’s place. Changing cultural and professional attitudes around the emotional bond between a man and a woman, family structure and the more proactive involved role of men in the family have encouraged fathers’ attendance at birth. There is evidence that fathers’ support can make birthing less traumatic for some women and can make couples closer. This has made some clinicians to believe the fathers should be more involved throughout the birth process. Some clinicians even go further and ask the fathers to watch the medical procedures, such as inserting vaginal speculum, forceps or vacuum, episiotomy and stitches. Although birth can unfold like a beautiful picture captured by birth photographers, with fathers massaging women’s backs by candle light and the miraculous moment of birth, it can be overshadowed by less attractive images of cervical mucous, emptying bowels and the invasive medical procedures. What happens in the birth room and the fathers’ reaction to the graphic experience of birthing can be unpredictable. Despite the fact that most men are absolutely thrilled to be in the delivery room, for some men, a very intimate body part can become completely desexualised, and they can experience psychological and sexual scarring. They see someone they cherish dramatically sliced open and can then associate their partners with a disturbing scene, and it can dramatically affect their relationships. While most women want the expectant fathers by their side for this life-changing event, not all of them may be happy for their partners to watch the perineum to be cut or stitched or when large blades of forceps are inserted inside the vagina. Anecdotal reports have shown that consent is not sought from the labouring women as to whether they want their partners to watch these procedures. The majority of research1, 2, 3 focuses on men’s and women’s retrospective attitudes towards their birth experience. However, the effect of witnessing invasive procedures during childbirth on a man's attraction to his partner, while she is most vulnerable, and also an increased risk of post-traumatic stress disorder in fathers have not been widely investigated. There is a lack of sufficient research investigating whether women need to be asked for their consent before inviting their partners to closely watch medical procedures during childbirth. Future research is required to provide a basis for better awareness and involve the consumers to understanding the men’s and women’s experience and their expectations for labour and birth.

Keywords: birth, childbirth, father, labour, men, women

Procedia PDF Downloads 90
6 Risk Factors for Maternal and Neonatal Morbidities Associated with Operative Vaginal Deliveries

Authors: Maria Reichenber Arcilla

Abstract:

Objective: To determine the risk factors for maternal and neonatal complications associated with operative vaginal deliveries. Methods: A retrospective chart review of 435 patients who underwent operative vaginal deliveries was done. Patient profiles – age, parity, AOG, duration of labor – and outcomes – birthweight, maternal and neonatal complications - were tabulated and multivariable analysis and logistic regression were performed using SPSS® Statistics Base. Results and Conclusion: There was no significant difference in the incidence of maternal and neonatal complications between those that underwent vacuum and forceps extraction. Among the variables analysed, parity and duration of labor reached statistical significance. The odds of maternal complications were 3 times higher among nulliparous patients. Neonatal complications were seen in those whose labor lasted more than 9 hours.

Keywords: operative vaginal deliveries, maternal, neonatal, morbidity

Procedia PDF Downloads 371
5 Microbial Corrosion on Oil and Gas Facilities: A Case Study of Oil and Gas Facilities in the Niger-Delta

Authors: Frederick Otite Ighovojah

Abstract:

Corrosion in the oil and gas industries is one of the most common causes of failure. Such failure includes leaks in above-ground storage tanks (AGST). The involvement of microorganisms in the corrosion process in AGST systems is often ignored, and this outlines the need to investigate the effect of microbial corrosion in oil and gas facilities. This study's methodology comprised gathering generated water samples from a nearby AGST oil facility that was operating, which were then equally divided into two batch reactors, 1 and 2. Each batch reactor was filled with five prepared X60 coupons using sterilized forceps. To provide nutrients for the microorganisms in batch reactor 1 during the test period, 2g of NPK 15- 15-15 fertilizer was added on a weekly basis. To kill the microorganisms and significantly lower their concentration in the generated water, 5ml of dissolved ozone (a biocide) with a 0.5ppm concentration was added to batch reactor 2. The weight loss measurement (WLM) was used to evaluate for corrosion. Coupons were removed from each batch reactor, and weight loss was measured at every interval of 336 hrs for 2016 hrs. The overall results obtained indicated that coupons from the batch 1 reactor showed a higher corrosion rate and higher mass loss, and this was due to the metabolic production of an aggressive compound in the medium.

Keywords: AGST, microbial corrosion, reactor, X60 steel

Procedia PDF Downloads 37
4 One Way to Address the Complications of Dental Implantology

Authors: Predrag Kavaric, Vladimir L. Jubic, Maxim Cadenovic

Abstract:

The patient was transferred from his dentist to our tertiary medical institution. In anamnesis, we got information that his dental intervention was two years ago when he got dental implants but because of the coronavirus pandemic event, he didn’t finish the whole procedure. After two years, he decided that he will continue his work at his dentist, then his dentist noticed that there is no earlier inserted implant in the upper jaw on the right side. They do Panoramic X-ray and find that the implant is all in the maxillary sinus cavity. The flour of the maxilla was intact without any fistula on the place where the implant was inserted in the maxilla bone, After that initial diagnostic they sent the patient to maxillofacial surgery and otorhinolaryngology. We asked for a CT scan of paranasal sinuses, which confirmed the foreign body in the right maxillary sinus. The plan was that in general anesthesia we do FESS and try to find a foreign body in the maxillary sinus or in case of failure to do Caldwel Luc on that side. After preoperative preparation in GA, we do FESS. In inspection, we find small polyps and chronically changed mucosa of osteomeatal complex and right maxillary sinus. After removing polyps we did uncinectomy and medial maxillectomy. With Heuweiser Antrum grasping forceps after several attempts we managed to extract a foreign body from the bottom of the right maxillary sinus. On the first postoperative day we did detamponade, and then we discharge the patient from hospital. The Covid pandemic has contributed to the postponement of a large number of planned operations, which has resulted in various complications in the treatment of a number of patients. In this case, it happened that the implant was most likely rejected by the bone but in the direction of the maxillary sinus, which is not a common cause. On the other hand, the success was that less traumatic intervention was able to remove the foreign body from the maxillary sinus in which it was located. Since the sinus floor is free of bone defects, it can be continued relatively quickly with dental procedures.

Keywords: x-ray, surgery, maxillar sinus, complication, fees

Procedia PDF Downloads 117
3 A Microsurgery-Specific End-Effector Equipped with a Bipolar Surgical Tool and Haptic Feedback

Authors: Hamidreza Hoshyarmanesh, Sanju Lama, Garnette R. Sutherland

Abstract:

In tele-operative robotic surgery, an ideal haptic device should be equipped with an intuitive and smooth end-effector to cover the surgeon’s hand/wrist degrees of freedom (DOF) and translate the hand joint motions to the end-effector of the remote manipulator with low effort and high level of comfort. This research introduces the design and development of a microsurgery-specific end-effector, a gimbal mechanism possessing 4 passive and 1 active DOFs, equipped with a bipolar forceps and haptic feedback. The robust gimbal structure is comprised of three light-weight links/joint, pitch, yaw, and roll, each consisting of low-friction support and a 2-channel accurate optical position sensor. The third link, which provides the tool roll, was specifically designed to grip the tool prongs and accommodate a low mass geared actuator together with a miniaturized capstan-rope mechanism. The actuator is able to generate delicate torques, using a threaded cylindrical capstan, to emulate the sense of pinch/coagulation during conventional microsurgery. While the tool left prong is fixed to the rolling link, the right prong bears a miniaturized drum sector with a large diameter to expand the force scale and resolution. The drum transmits the actuator output torque to the right prong and generates haptic force feedback at the tool level. The tool is also equipped with a hall-effect sensor and magnet bar installed vis-à-vis on the inner side of the two prongs to measure the tooltip distance and provide an analogue signal to the control system. We believe that such a haptic end-effector could significantly increase the accuracy of telerobotic surgery and help avoid high forces that are known to cause bleeding/injury.

Keywords: end-effector, force generation, haptic interface, robotic surgery, surgical tool, tele-operation

Procedia PDF Downloads 87
2 Comparative Study for Neonatal Outcome and Umbilical Cord Blood Gas Parameters in Balanced and Inhalant Anesthesia for Elective Cesarean Section in Dogs

Authors: Agnieszka Antończyk, MałGorzata Ochota, Wojciech Niżański, ZdzisłAw Kiełbowicz

Abstract:

The goal of the cesarean section (CS) is the delivery of healthy, vigorous pups with the provision of surgical plane anesthesia, appropriate analgesia, and rapid recovery of the dam. In human medicine, spinal or epidural anesthesia is preferred for a cesarean section as associated with a lower risk of neonatal asphyxia and the need for resuscitation. Nevertheless, the specificity of veterinary patients makes the application of regional anesthesia as a sole technique impractical, thus to obtain patient compliance the general anesthesia is required. This study aimed to compare the influence of balanced (inhalant with epidural) and inhalant anesthesia on neonatal umbilical cord blood gas (UCBG) parameters and vitality (modified Apgar scoring). The bitches (31) undergoing elective CS were enrolled in this study. All females received a single dose of 0.2 mg/kg s.c. Meloxicam. Females were randomly assigned into two groups: Gr I (Isoflurane, n=16) and Gr IE (Isoflurane plus Epidural, n=15). Anesthesia was induced with propofol at 4-6 mg/kg to effect, and maintained with isoflurane in oxygen; in IE group epidural anesthesia was also done using lidocaine (3-4 mg/kg) into the lumbosacral space. CSs were performed using a standard mid-line approach. Directly after the puppy extraction, the umbilical cord was double clamped before the placenta detachment. The vessels were gently stretched between forceps to allow blood sampling. At least 100 mcl of mixed umbilical cord blood was collected into a heparinized syringe for further analysis. The modified Apgar scoring system (AS) was used to objectively score neonatal health and vitality immediately after birth (before first aid or neonatal care was instituted), at 5 and 20 min after birth. The neonates were scored as normal (AS 7-10), weak (AS 4-6), or critical (AS 0-3). During surgery, the IE group required a lower isoflurane concentration compared to the females in group I (MAC 1.05±0.2 and 1.4±0.13, respectively, p<0.01). All investigated UCBG parameters were not statistically different between groups. All pups had mild acidosis (pH 7.21±0.08 and 7.21±0.09 in Gr I and IE, respectively) with moderately elevated pCO2 (Gr I 57.18±11.48, Gr IE 58.74±15.07), HCO3- on the lower border (Gr I 22.58±3.24, Gr IE 22.83±3.6), lowered BE (Gr I -6.1±3.57, Gr IE -5.6±4.19) and mildly elevated level of lactates (Gr I 2.58±1.48, Gr IE2.53±1.03). The glucose levels were above the reference limits in both groups of puppies (74.50±25.32 in Gr I, 79.50±29.73 in Gr IE). The initial Apgar score results were similar in I and IE groups. However, the subsequent measurements of AS revealed significant differences between both groups. Puppies from the IE group received better AS scores at 5 and 20 min compared to the I group (6.86±2.23 and 8.06±2.06 vs 5.11±2.40 and 7.83±2.05, respectively). The obtained results demonstrated that administration of epidural anesthesia reduced the requirement for isoflurane in dams undergoing cesarean section and did not affect the neonatal umbilical blood gas results. Moreover, newborns from the epidural anesthesia group were scored significantly higher in AS at 5 and 20 min, indicating their better vitality and quicker improvement post-surgery.

Keywords: apgar scoring, balanced anesthesia, cesarean section, umbilical blood gas

Procedia PDF Downloads 140
1 A Rare Case of Dissection of Cervical Portion of Internal Carotid Artery, Diagnosed Postpartum

Authors: Bidisha Chatterjee, Sonal Grover, Rekha Gurung

Abstract:

Postpartum dissection of the internal carotid artery is a relatively rare condition and is considered as an underlying aetiology in 5% to 25% of strokes under the age of 30 to 45 years. However, 86% of these cases recover completely and 14% have mild focal neurological symptoms. Prognosis is generally good with early intervention. The risk quoted for a repeat carotid artery dissection in subsequent pregnancies is less than 2%. 36-year Caucasian primipara presented on postnatal day one of forceps delivery with tachycardia. In the intrapartum period she had a history of prolonged rupture of membranes and developed intrapartum sepsis and was treated with antibiotics. Postpartum ECG showed septal inferior T wave inversion and a troponin level of 19. Subsequently Echocardiogram ruled out post-partum cardiomyopathy. Repeat ECG showed improvement of the previous changes and in the absence of symptoms no intervention was warranted. On day 4 post-delivery, she had developed symptoms of droopy right eyelid, pain around the right eye and itching in the right ear. On examination, she had developed right sided ptosis, unequal pupils (Rt miotic pupil). Cranial nerve examination, reflexes, sensory examination and muscle power was normal. Apart from migraine, there was no medical or family history of note. In view of Horner’s on the right, she had a CT Angiogram and subsequently MR/MRA and was diagnosed with dissection of the cervical portion of the right internal carotid artery. She was discharged on a course of Aspirin 75mg. By 6 week post-natal follow up patient had recovered significantly with occasional episodes of unequal pupils and tingling of right toes which resolved spontaneously. Cervical artery dissection, including VAD and carotid artery dissection, are rare complications of pregnancy with an estimated annual incidence of 2.6–3 per 100,000 pregnancy hospitalizations. Aetiology remains unclear though trauma during straining at labour, underlying arterial disease and preeclampsia have been implicated. Hypercoagulable state during pregnancy and puerperium could also be an important factor. 60-90% cases present with severe headache and neck pain and generally precede neurological symptoms like ipsilateral Horner’s syndrome, retroorbital pain, tinnitus and cranial nerve palsy. Although rare, the consequences of delayed diagnosis and management can lead to severe and permanent neurological deficits. Patients with a strong index of suspicion should undergo an MRI or MRA of head and neck. Antithrombotic and antiplatelet therapy forms the mainstay of therapy with selected cases needing endovascular stenting. Long term prognosis is favourable with either complete resolution or minimal deficit if treatment is prompt. Patients should be counselled about the recurrence risk and possibility of stroke in future pregnancy. Coronary artery dissection is rare and treatable but needs early diagnosis and treatment. Post-partum headache and neck pain with neurological symptoms should prompt urgent imaging followed by antithrombotic and /or antiplatelet therapy. Most cases resolve completely or with minimal sequelae.

Keywords: postpartum, dissection of internal carotid artery, magnetic resonance angiogram, magnetic resonance imaging, antiplatelet, antithrombotic

Procedia PDF Downloads 63