Search results for: breakout rooms
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 214

Search results for: breakout rooms

184 Horizontal Stress Magnitudes Using Poroelastic Model in Upper Assam Basin, India

Authors: Jenifer Alam, Rima Chatterjee

Abstract:

Upper Assam sedimentary basin is one of the oldest commercially producing basins of India. Being in a tectonically active zone, estimation of tectonic strain and stress magnitudes has vast application in hydrocarbon exploration and exploitation. This East North East –West South West trending shelf-slope basin encompasses the Bramhaputra valley extending from Mikir Hills in the southwest to the Naga foothills in the northeast. Assam Shelf lying between the Main Boundary Thrust (MBT) and Naga Thrust area is comparatively free from thrust tectonics and depicts normal faulting mechanism. The study area is bounded by the MBT and Main Central Thrust in the northwest. The Belt of Schuppen in the southeast, is bordered by Naga and Disang thrust marking the lower limit of the study area. The entire Assam basin shows low-level seismicity compared to other regions of northeast India. Pore pressure (PP), vertical stress magnitude (SV) and horizontal stress magnitudes have been estimated from two wells - N1 and T1 located in Upper Assam. N1 is located in the Assam gap below the Bramhaputra river while T1, lies in the Belt of Schuppen. N1 penetrates geological formations from top Alluvial through Dhekiajuli, Girujan, Tipam, Barail, Kopili, Sylhet and Langpur to the granitic basement while T1 in trusted zone crosses through Girujan Suprathrust, Tipam Suprathrust, Barail Suprathrust to reach Naga Thrust. Normal compaction trend is drawn through shale points through both wells for estimation of PP using the conventional Eaton sonic equation with an exponent of 1.0 which is validated with Modular Dynamic Tester and mud weight. Observed pore pressure gradient ranges from 10.3 MPa/km to 11.1 MPa/km. The SV has a gradient from 22.20 to 23.80 MPa/km. Minimum and maximum horizontal principal stress (Sh and SH) magnitudes under isotropic conditions are determined using poroelastic model. This approach determines biaxial tectonic strain utilizing static Young’s Modulus, Poisson’s Ratio, SV, PP, leak off test (LOT) and SH derived from breakouts using prior information on unconfined compressive strength. Breakout derived SH information is used for obtaining tectonic strain due to lack of measured SH data from minifrac or hydrofracturing. Tectonic strain varies from 0.00055 to 0.00096 along x direction and from -0.0010 to 0.00042 along y direction. After obtaining tectonic strains at each well, the principal horizontal stress magnitudes are calculated from linear poroelastic model. The magnitude of Sh and SH gradient in normal faulting region are 12.5 and 16.0 MPa/km while in thrust faulted region the gradients are 17.4 and 20.2 MPa/km respectively. Model predicted Sh and SH matches well with the LOT data and breakout derived SH data in both wells. It is observed from this study that the stresses SV>SH>Sh prevailing in the shelf region while near the Naga foothills the regime changes to SH≈SV>Sh area corresponds to normal faulting regime. Hence this model is a reliable tool for predicting stress magnitudes from well logs under active tectonic regime in Upper Assam Basin.

Keywords: Eaton, strain, stress, poroelastic model

Procedia PDF Downloads 179
183 The Efficiency of the Resin for Steel Concrete Adhesion

Authors: Oualid Benyamina Douma

Abstract:

Repair is always the result of the appearance of apparent disorder or aggravation of a mass. Which had hitherto been considered minor if not negligible: The work was not done according to plan. So; the examination of causes can lead to thinking about repair. While the application of the epoxy resin has become a hot topic. In this context, we conducted an experimental campaign (48 specimens are tested beakout) whose objective is based on three points: 1- Highlight the importance and influence of important parameters (compressive strength of concrete anchorage length and diameter of the steel bar) on routes (steel-concrete and steel–concrete epoxy resin) 2- Understanding the influence of the parameters mentioned above on the relationship that may exist between the peel strength and slippage. 3- Faces of cracks and failure modes. This study shows that passage of a compressive strength of 40 MPa to 62 MPa increases the adhesion between the steel bar and concrete and for specimens with or without epoxy resin. The loading force was increased form 40 to 81 kM kN, a rate if increase in loading over 100% In addition, for specimens with and without epoxy resin. increased breakout force through a specimen without a specimen with resin ranging from 20% to 32%.

Keywords: epoxy resin, peel strength, anchors, slip diameter steel rod, anchor plain concrete and concrete with moderate resistance

Procedia PDF Downloads 404
182 Reduction of Cooling Demands in a Subtropical Humid Climate Zone: A Study on Roofs of Existing Residential Building Using Passive

Authors: Megha Jain, K. K. Pathak

Abstract:

In sub-tropical humid climates, it is estimated most of the urban peak load of energy consumption is used to satisfy air-conditioning or air-coolers cooling demand in summer time. As the urbanization rate in developing nation – like the case in India is rising rapidly, the pressure placed on energy resources to satisfy inhabitants’ indoor comfort requirements is consequently increasing too. This paper introduces passive cooling through roof as a means of reducing energy cooling loads for satisfying human comfort requirements in a sub-tropical climate. Experiments were performed by applying different insulators which are locally available solar reflective materials to insulate the roofs of five rooms of 4 case buildings; three rooms having RCC (Reinforced Cement Concrete) roof and two having Asbestos sheet roof of existing buildings. The results are verified by computer simulation using Computational Fluid Dynamics tools with FLUENT software. The result of using solar reflective paint with high albedo coating shows a fall of 4.8⁰C in peak hours and saves 303 kWh considering energy load with air conditioner during the summer season in comparison to non insulated flat roof energy load of residential buildings in Bhopal. An optimum solution of insulator for both types of roofs is presented. It is recommended that the selected cool roof solution be combined with insulation on other elements of envelope, to increase the indoor thermal comfort. The application is intended for low cost residential buildings in composite and warm climate like Bhopal.

Keywords: cool roof, computational fluid dynamics, energy loads, insulators, passive cooling, subtropical climate, thermal performance

Procedia PDF Downloads 145
181 The Influence of the Visual and the Direct Physical Accessibility on the Sense of Control of Saudi Women in the Home Environment

Authors: Ahdab H. Mahdaly, Debajyoti Pati, Sharran Parkinson, Lee S. Duemer

Abstract:

The importance of providing employed mothers with the right physical environment inside the home is not an easy task, especially when the culture is involved. This study examines the typical Saudi home as a personal, emotional, social and cultural setting, especially on the interactions between the physical design and perceived control of working mothers. However, owing to the scarcity of published literature on Saudi homes, American employed mothers were included in the study to provide a baseline. With the ongoing transformations in women’s role in Saudi Arabia, there is a perception that traditional home designs may not afford the appropriate sense of control inside the home. Saudi Arabia has numerous interacting layers of socio-cultural-religious forces that affect residential design, and understanding the moderating role of the Saudi home is vital to the ongoing national policy transition on women. The study investigated one narrow, albeit critical, influence of home design on ones sense of control – direct visual and physical accessibility between sets of rooms. Ten subjects, five Saudis and five American, examined visual and physical access between 171 room sets, and provided qualitative responses on how each access influences their sense of control. Three main themes emerged, with potential effects on control: 1- Openness, 2- Proximity, and 3- Separation. Data suggest that although the Saudi home is a substantially more complex setting than the American ones, a class of spaces that can be termed as ‘Neutral Rooms’ serving as cultural separators may represent the ideal solution for optimizing sense of control, without ignoring cultural-religious traditions, during the transition of the Saudi women.

Keywords: direct physical accessibility, home environment, sense of control, visual accessibility, working mothers

Procedia PDF Downloads 288
180 A Study of the Implications for the Health and Wellbeing of Energy-Efficient House Occupants: A UK-Based Investigation of Indoor Climate and Indoor Air Quality

Authors: Patricia Kermeci

Abstract:

Policies related to the reduction of both carbon dioxide and energy consumption within the residential sector have contributed towards a growing number of energy-efficient houses being built in several countries. Many of these energy-efficient houses rely on the construction of very well insulated and highly airtight structures, ventilated mechanically. Although energy-efficient houses are indeed more energy efficient than conventional houses, concerns have been raised over the quality of their indoor air and, consequently, the possible adverse health and wellbeing effects for their occupants. Using a longitudinal study design over three different weather seasons (winter, spring and summer), this study has investigated the indoor climate and indoor air quality of different rooms (bedroom, living room and kitchen) in five energy-efficient houses and four conventional houses in the UK. Occupants have kept diaries of their activities during the studied periods and interviews have been conducted to investigate possible behavioural explanations for the findings. Data has been compared with reviews of epidemiological, toxicological and other health related published literature to reveals three main findings. First, it shows that the indoor environment quality of energy-efficient houses cannot be treated as a holistic entity as different rooms presented dissimilar indoor climate and indoor air quality. Thus, such differences might contribute to the health and wellbeing of occupants in different ways. Second, the results show that the indoor environment quality of energy-efficient houses can vary following changes in weather season, leaving occupants at a lower or higher risk of adverse health and wellbeing effects during different weather seasons. Third, one cannot assume that even identical energy-efficient houses provide a similar indoor environment quality. Fourth, the findings reveal that the practices and behaviours of the occupants of energy-efficient houses likely determine whether they enjoy a healthier indoor environment when compared with their control houses. In conclusion, it has been considered vital to understand occupants’ practices and behaviours in order to explain the ways they might contribute to the indoor climate and indoor air quality in energy-efficient houses.

Keywords: energy-efficient house, health and wellbeing, indoor environment, indoor air quality

Procedia PDF Downloads 198
179 Evaluating the Effect of Spatial Qualities, Openness and Complexity, on Human Cognitive Performance within Virtual Reality

Authors: Pierre F. Gerard, Frederic F. Leymarie, William Latham

Abstract:

Architects have developed a series of objective evaluations, using spatial analysis tools such as Isovist, that show how certain spatial qualities are beneficial to specific human activities hosted in the built environments. In return, they can build more adapted environments by tuning those spatial qualities in their design. In parallel, virtual reality technologies have been developed by engineers with the dream of creating a system that immerses users in a new form of spatial experiences. They already have demonstrated a useful range of benefits not only in simulating critical events to assist people in acquiring new skills, but also to enhance memory retention, to name just a few. This paper investigates the effects of two spatial qualities, openness, and complexity, on cognitive performance within immersive virtual environments. Isovist measure is used to design a series of room settings with different levels of each spatial qualities. In an empirical study, each room was then used by every participant to solve a navigational puzzle game and give a rating of their spatial experience. They were then asked to fill in a questionnaire before solving the visual-spatial memory quiz, which addressed how well they remembered the different rooms. Findings suggest that those spatial qualities have an effect on some of the measures, including navigation performance and memory retention. In particular, there is an order effect for the navigation puzzle game. Participants tended to spend a longer time in the complex room settings. Moreover, there is an interaction effect while with more open settings, participants tended to perform better when in a simple setting; however, with more closed settings, participants tended to perform better in a more complex setting. For the visual-spatial memory quiz, participants performed significantly better within the more open rooms. We believe this is a first step in using virtual environments to enhance participant cognitive performances through better use of specific spatial qualities.

Keywords: architecture, navigation, spatial cognition, virtual reality

Procedia PDF Downloads 96
178 A System for Preventing Inadvertent Exposition of Staff Present outside the Operating Theater: Description and Clinical Test

Authors: Aya Al Masri, Kamel Guerchouche, Youssef Laynaoui, Safoin Aktaou, Malorie Martin, Fouad Maaloul

Abstract:

Introduction: Mobile C-arms move throughout operating rooms of the operating theater. Being designed to move between rooms, they are not equipped with relays to retrieve the exposition information and export it outside the room. Therefore, no light signaling is available outside the room to warn the X-ray emission for staff. Inadvertent exposition of staff outside the operating theater is a real problem for radiation protection. The French standard NFC 15-160 require that: (1) access to any room containing an X-ray emitting device must be controlled by a light signage so that it cannot be inadvertently crossed, and (2) setting up an emergency button to stop the X-ray emission. This study presents a system that we developed to meet these requirements and the results of its clinical test. Materials and methods: The system is composed of two communicating boxes: o The "DetectBox" is to be installed inside the operating theater. It identifies the various operation states of the C-arm by analyzing its power supply signal. The DetectBox communicates (in wireless mode) with the second box (AlertBox). o The "AlertBox" can operate in socket or battery mode and is to be installed outside the operating theater. It detects and reports the state of the C-arm by emitting a real time light signal. This latter can have three different colors: red when the C-arm is emitting X-rays, orange when it is powered on but does not emit X-rays, and green when it is powered off. The two boxes communicate on a radiofrequency link exclusively carried out in the ‘Industrial, Scientific and Medical (ISM)’ frequency bands and allows the coexistence of several on-site warning systems without communication conflicts (interference). Taking into account the complexity of performing electrical works in the operating theater (for reasons of hygiene and continuity of medical care), this system (having a size <10 cm²) works in complete safety without any intrusion in the mobile C-arm and does not require specific electrical installation work. The system is equipped with emergency button that stops X-ray emission. The system has been clinically tested. Results: The clinical test of the system shows that: it detects X-rays having both high and low energy (50 – 150 kVp), high and low photon flow (0.5 – 200 mA: even when emitted for a very short time (<1 ms)), Probability of false detection < 10-5, it operates under all acquisition modes (continuous, pulsed, fluoroscopy mode, image mode, subtraction and movie mode), it is compatible with all C-arm models and brands. We have also tested the communication between the two boxes (DetectBox and AlertBox) in several conditions: (1) Unleaded room, (2) leaded room, and (3) rooms with particular configuration (sas, great distances, concrete walls, 3 mm of lead). The result of these last tests was positive. Conclusion: This system is a reliable tool to alert the staff present outside the operating room for X-ray emission and insure their radiation protection.

Keywords: Clinical test, Inadvertent staff exposition, Light signage, Operating theater

Procedia PDF Downloads 100
177 A Post-Occupancy Evaluation of the Impact of Indoor Environmental Quality on Health and Well-Being in Office Buildings

Authors: Suyeon Bae, Abimbola Asojo, Denise Guerin, Caren Martin

Abstract:

Post-occupancy evaluations (POEs) have been recognized for documenting occupant well-being and responses to indoor environmental quality (IEQ) factors such as thermal, lighting, and acoustic conditions. Sustainable Post-Occupancy evaluation survey (SPOES) developed by an interdisciplinary team at a Midwest University provides an evidence-based quantitative analysis of occupants’ satisfaction in office, classroom, and residential spaces to help direct attention to successful areas and areas that need improvement in buildings. SPOES is a self-administered and Internet-based questionnaire completed by building occupants. In this study, employees in three different office buildings rated their satisfaction on a Likert-type scale about 12 IEQ criteria including thermal condition, indoor air quality, acoustic quality, daylighting, electric lighting, privacy, view conditions, furnishings, appearance, cleaning and maintenance, vibration and movement, and technology. Employees rated their level of satisfaction on a Likert-type scale from 1 (very dissatisfied) to 7 (very satisfied). They also rate the influence of their physical environment on their perception of their work performance and the impact of their primary workspaces on their health on a scale from 1 (hinders) to 7 (enhances). Building A is a three-story building that includes private and group offices, classrooms, and conference rooms and amounted to 55,000 square-feet for primary workplace (N=75). Building B, a six-story building, consisted of private offices, shared enclosed office, workstations, and open desk areas for employees and amounted to 14,193 square-feet (N=75). Building C is a three-story 56,000 square-feet building that included classrooms, therapy rooms, an outdoor playground, gym, restrooms, and training rooms for clinicians (N=76). The results indicated that 10 IEQs for Building A except acoustic quality and privacy showed statistically significant correlations on the impact of the primary workspace on health. In Building B, 11 IEQs except technology showed statistically significant correlations on the impact of the primary workspace on health. Building C had statistically significant correlations between all 12 IEQ and the employees’ perception of the impact of their primary workspace on their health in two-tailed correlations (P ≤ 0.05). Out of 33 statistically significant correlations, 25 correlations (76%) showed at least moderate relationship (r ≥ 0.35). For the three buildings, daylighting, furnishings, and indoor air quality IEQs ranked highest on the impact on health. IEQs about vibration and movement, view condition, and electric lighting ranked second, followed by IEQs about cleaning and maintenance and appearance. These results imply that 12 IEQs developed in SPOES are highly related to employees’ perception of how their primary workplaces impact their health. The IEQs in this study offer an opportunity for improving occupants’ well-being and the built environment.

Keywords: post-occupancy evaluation, built environment, sustainability, well-being, indoor air quality

Procedia PDF Downloads 257
176 Improving Pediatric Patient Experience

Authors: Matthew Pleshaw, Caroline Lynch, Caleb Eaton, Ali Kiapour

Abstract:

The problem addressed in this proposal is that of the lacking comfort and safety of inpatient rooms, specifically at Boston Children’s Hospital, with the implementation of a system that will allow inpatient children to feel more comfortable in the unfamiliar environment of a hospital. The focus is that of advancing and enhancing the healing process for children in a long-term inpatient stay at the hospital, though a combination of announcing a clinician or hospital staff’s arrival utilizing RFID (Fig. 1), and improving communication between clinicians, parents/guardians, patients, etc. by integrating a mobile application.

Keywords: Pediatrics, Hospital, RFID, Technology

Procedia PDF Downloads 132
175 Teaching University Students Lateral Reading to Detect Disinformation and Misinformation

Authors: Diane Prorak, Perri Moreno

Abstract:

University students may have been born in the digital age, but they need to be taught the critical thinking skills to detect misinformation and social media manipulation online. In recent years, librarians have been active in designing instructional methods to help students learn information evaluation skills. At the University of Idaho Library (USA), librarians have developed new teaching methods for these skills. Last academic year, when classes were taught via Zoom, librarians taught these skills to an online session of each first-year rhetoric and composition course. In the Zoom sessions, students were placed in breakout groups where they practiced using an evaluation method known as lateral reading. Online collaborative software was used to give each group an evaluative task and break the task into steps. Groups reported back to the full class. Students learned to look at an information source, then search outside the source to find information about the organization, publisher or author, before evaluating the source itself. Class level pre-and post-test comparison results showed students learned better techniques for evaluation than they knew before instruction.

Keywords: critical thinking, information evaluation, information literacy instruction, lateral reading.

Procedia PDF Downloads 154
174 Application of Building Information Modeling in Energy Management of Individual Departments Occupying University Facilities

Authors: Kung-Jen Tu, Danny Vernatha

Abstract:

To assist individual departments within universities in their energy management tasks, this study explores the application of Building Information Modeling in establishing the ‘BIM based Energy Management Support System’ (BIM-EMSS). The BIM-EMSS consists of six components: (1) sensors installed for each occupant and each equipment, (2) electricity sub-meters (constantly logging lighting, HVAC, and socket electricity consumptions of each room), (3) BIM models of all rooms within individual departments’ facilities, (4) data warehouse (for storing occupancy status and logged electricity consumption data), (5) building energy management system that provides energy managers with various energy management functions, and (6) energy simulation tool (such as eQuest) that generates real time 'standard energy consumptions' data against which 'actual energy consumptions' data are compared and energy efficiency evaluated. Through the building energy management system, the energy manager is able to (a) have 3D visualization (BIM model) of each room, in which the occupancy and equipment status detected by the sensors and the electricity consumptions data logged are displayed constantly; (b) perform real time energy consumption analysis to compare the actual and standard energy consumption profiles of a space; (c) obtain energy consumption anomaly detection warnings on certain rooms so that energy management corrective actions can be further taken (data mining technique is employed to analyze the relation between space occupancy pattern with current space equipment setting to indicate an anomaly, such as when appliances turn on without occupancy); and (d) perform historical energy consumption analysis to review monthly and annually energy consumption profiles and compare them against historical energy profiles. The BIM-EMSS was further implemented in a research lab in the Department of Architecture of NTUST in Taiwan and implementation results presented to illustrate how it can be used to assist individual departments within universities in their energy management tasks.

Keywords: database, electricity sub-meters, energy anomaly detection, sensor

Procedia PDF Downloads 282
173 Pore Pressure and In-situ Stress Magnitudes with Image Log Processing and Geological Interpretation in the Haoud Berkaoui Hydrocarbon Field, Northeastern Algerian Sahara

Authors: Rafik Baouche, Rabah Chaouchi

Abstract:

This work reports the first comprehensive stress field interpretation from the eleven recently drilled wells in the Berkaoui Basin, Algerian Sahara. A cumulative length of 7000+m acoustic image logs from 06 vertical wells were investigated, and a mean NW-SE (128°-145° N) maximum horizontal stress (SHMax) orientation is inferred from the B-D quality wellbore breakouts. The study integrates log-based approach with the downhole measurements to infer pore pressure, in-situ stress magnitudes. Vertical stress (Sv), interpreted from the bulk-density profiles, has an average gradient of 22.36 MPa/km. The Ordovician and Cambrian reservoirs have a pore pressure gradient of 13.47-13.77 MPa/km, which is more than the hydrostatic pressure regime. A 17.2-18.3 MPa/km gradient of minimum horizontal stress (Shmin) is inferred from the fracture closure pressure in the reservoirs. Breakout widths constrained the SHMax magnitude in the 23.8-26.5 MPa/km range. Subsurface stress distribution in the central Saharan Algeria indicates that the present-day stress field in the Berkaoui Basin is principally strike-slip faulting (SHMax > Sv > Shmin). Inferences are drawn on the regional stress pattern and drilling and reservoir development.

Keywords: stress, imagery, breakouts, sahara

Procedia PDF Downloads 45
172 Human Factors Issues and Measures in Advanced NPPs

Authors: Jun Su Ha

Abstract:

Various advanced technologies will be adopted in Advanced Control Rooms (ACRs) of advanced Nuclear Power Plants (NPPs), which is thought to increase operators’ performance. However, potential human factors issues coupled with digital technologies might be troublesome. Human factors issues in ACRs are identified and strategies (or countermeasures) for evaluating and analyzing each of issues are addressed in this study.

Keywords: advanced control room, human factor issues, human performance, human error, nuclear power plant

Procedia PDF Downloads 436
171 Evaluation of Indoor Radon as Air Pollutant in Schools and Control of Exposure of the Children

Authors: Kremena Ivanona, Bistra Kunovska, Jana Djunova, Desislava Djunakova, Zdenka Stojanovska

Abstract:

In recent decades, the general public has become increasingly interested in the impact of air pollutions on their health. Currently, numerous studies are aimed at identifying pollutants in the indoor environment where they carry out daily activities. Internal pollutants can be of both natural and artificial origin. With regard to natural pollutants, special attention is paid to natural radioactivity. In recent years, radon has been one of the most studied indoor pollutants because it has the greatest contribution to human exposure to natural radionuclides. It is a known fact that lung cancer can be caused by radon radiation and it is the second risk factor after smoking for the onset of the disease. The main objective of the study under the National Science Fund of Bulgaria, in the framework of grant No КП-06-Н23/1/07.12.2018 is to evaluate the indoor radon as an important air pollutant in school buildings in order to reduce the exposure to children. The measurements were performed in 48 schools located in 55 buildings in one Bulgarian administrative district (Kardjaly). The nuclear track detectors (CR-39) were used for measurements. The arithmetic and geometric means of radon concentrations are AM = 140 Bq/m3, and GM = 117 Bq/m3 respectively. In 51 school rooms, the radon levels were greater than 200 Bq/m3, and in 28 rooms, located in 17 school buildings, it exceeded the national reference level of 300 Bq/m3, defined in the Bulgarian ordinance on radiation protection (or 30% of the investigated buildings). The statistically significant difference in the values of radon concentration by municipalities (KW, р < 0.001) obtained showed that the most likely reason for the differences between the groups is the geographical location of the buildings and the possible influence of the geological composition. The combined effect of the year of construction (technical condition of the buildings) and the energy efficiency measures was considered. The values of the radon concentration in the buildings where energy efficiency measures have been implemented are higher than those in buildings where they have not been performed. This result confirms the need for investigation of radon levels before conducting the energy efficiency measures in buildings. Corrective measures for reducing the radon levels have been recommended in school buildings with high radon levels in order to decrease the children's exposure.

Keywords: air pollution, indoor radon, children exposure, schools

Procedia PDF Downloads 145
170 Effect of Pulmonary Rehabilitation towards Length of Stay and IL-6 Level on Community-Acquired Pneumonia Patients

Authors: Santony Santony, Teguh Rahayu Sartono, Iin Noor Chozin

Abstract:

Introduction: Pneumonia is acute inflammation on lung parenchyma which is caused by bacteria, virus, fungi, or parasite. In Indonesia, Pneumonia is among the ten inpatient cases. Length of stay is related to the increased morbidity rate, nosocomial infection, and costs. The aim of this study is to assess the effect of pulmonary rehabilitation on the difference in length of stay and the level of Interleukin 6 (IL-6) as an inflammation biomarker for community-acquired pneumonia (CAP) patients in non-intensive rooms. Therefore, pulmonary rehabilitation as adjunctive therapy can be routinely exercised in order to shorten the length of stay, along with the decrease in IL-6 level. Methods: This study was conducted from May to October 2019 at Saiful Anwar General Hospital, Malang. 40 community-acquired pneumonia patients in non-intensive rooms were divided into two groups. 20 patients in the treatment group and 20 patients in the control group, all of them were selected through both inclusion and exclusion criteria. This study used simple consecutive random sampling. In the treatment group, pulmonary rehabilitation performed was composed of breathing exercise, effective coughing technique, clapping (percussion), postural drainage, as well as respiratory muscle training using incentive spirometry device. Pulmonary rehabilitation was conducted twice over five days with a minimum duration of 15 minutes. Blood samples were taken both on the first and the fifth day of the treatment to measure IL-6 level as an inflammation biomarker. Result: For the treatment group, the length of stay was 5.35 days whereas the control group 7.6 days. It can be seen that the treatment group had a shorter length of stay by 2.25 days (P<0,001). The IL-6 level on the first day for the treatment group was 36.27 pg/ml, whereas on the fifth day was 34.36 pg/ml. There was a decrease in IL-6 level on the fifth day of treatment even though it was not statistically significant (P=0.628). IL-6 level on the control group for the first day was 67.76 pg/ml, and after the fifth day, the level decreased to 54.43 pg/ml. There seemed to be a decrease in the IL-6, but it was not statistically significant (P=0.502). On the fifth day, the treatment group showed an average IL-6 level of 34.36 pg/ml. This value was lower than that of the control group which did not receive pulmonary rehabilitation having an IL-6 level of 54.43 pg/ml, even though it was not statistically significant (p=0.221). Conclusion: This study concluded that pulmonary rehabilitation as an adjunctive therapy shortened length of stay by 2.25 days for community-acquired pneumonia patients in a non-intensive room. Both groups experienced a decrease in IL-6 level on the fifth day in comparison with the first day even though it was not statistically significant P>0,05. IL-6 level as an inflammation biomarker decreased on the fifth day of treatment which was in accordance with improvement on pneumonia patients.

Keywords: community-acquired pneumonia, interleukin-6, length of stay, pulmonary rehabilitation

Procedia PDF Downloads 76
169 Communication Strategies of Russian-English Asymmetric Bilinguals Given Insufficient Language Faculty

Authors: Varvara Tyurina

Abstract:

In the age of globalization Internet communication as a new format of interactions have become an integral part of our daily routine. Internet environment allows for new conditions and provides participants to a communication act with extra communication tools which can be used on Internet forums or in chat rooms. As a result communicants tend to alternate their behavior patterns in contrast to those practiced in live communication. It is not yet clear which communication strategies participants to Internet communication abide by and what determines their choices. Given the continually changing environment of a forum or a chat the behavior of a communicant can be interpreted in terms of autopoiesis theory which sees adaptation as the major tool for coexistence between the living system and its niche. Each communication act is seen as interaction between the communicant (i.e. the living system) and the overall environment of the forum (i.e. the niche) rather than one particular interlocutor. When communicating via the Internet participants are believed to aim at reaching a balance between themselves and the environment of a forum or a chat. The research focuses on unveiling the adaptation strategies employed by a communicant in particular cases and looks into the reasons they are employed. There is a correlation between language faculty of the communicants and the strategies they opt for when communicating on Internet forums and in chat rooms. The research included an experiment with a sample of Russian-English asymmetric bilinguals aged 16-25. Respondents were given two texts of equivalent contents, but of different language complexity. They had to respond to the texts as if they were making a reciprocal comment at a forum. It has been revealed that when communicants realize that their language faculty is not sufficient to understand the initial text they tend to amend their communication strategy in order to maintain the balance with the niche (remain involved in the communication). Most common strategies for responding to a difficult-to-understand text were self-presentation, veiling poor language faculty and response evasion. The research has so far focused on a very narrow aspect of correlation between language faculty and communication behavior, namely the syntactic and lexicological complexity of initial texts. It is essential to conduct a series of experiments that dwell on other characteristics of the texts to determine the range of cases when language faculty determines the choice of adaptation strategy.

Keywords: adaptation, communication strategies, internet communication, verbal interaction, autopoiesis theory

Procedia PDF Downloads 331
168 The Influence of Cage versus Floor Pen Management of Broilers

Authors: Hanan Al-Khalifa

Abstract:

There has been an interest in raising poultry in environmentally controlled cages rather than on floor, because poultry raised on floor are more susceptible to environmental stress including pathogens and heat stress. A study was conducted to investigate the effect of managerial environmental conditions on body weight gain of Cobb 500 broiler breed. Broilers were raised in cages and on floor in two separate rooms. Body weight at different ages of the broilers was monitored. It was found that body weight at slaughter age (5weeks) for boilers raised in batteries were significantly higher than those raised on the floor.

Keywords: broilers, cages, floor, poultry

Procedia PDF Downloads 385
167 Influence of Concrete Cracking in the Tensile Strength of Cast-in Headed Anchors

Authors: W. Nataniel, B. Lima, J. Manoel, M. P. Filho, H. Marcos, Oliveira Mauricio, P. Ferreira

Abstract:

Headed reinforcement bars are increasingly used for anchorage in concrete structures. Applications include connections in composite steel-concrete structures, such as beam-column joints, in several strengthening situations as well as in more traditional uses in cast-in-place and precast structural systems. This paper investigates the reduction in the ultimate tensile capacity of embedded cast-in headed anchors due to concrete cracking. A series of nine laboratory tests are carried out to evaluate the influence of cracking on the concrete breakout strength in tension. The experimental results show that cracking affects both the resistance and load-slip response of the headed bar anchors. The strengths measured in these tests are compared to theoretical resistances calculated following the recommendations presented by fib Bulletin no. 58 (2011), ETAG 001 (2010) and ACI 318 (2014). The influences of parameters such as the effective embedment depth (hef), bar diameter (ds), and the concrete compressive strength (fc) are analysed and discussed. The theoretical recommendations are shown to be over-conservative for both embedment depths and were, in general, inaccurate in comparison to the experimental trends. The ACI 318 (2014) was the design code which presented the best performance regarding to the predictions of the ultimate load, with an average of 1.42 for the ratio between the experimental and estimated strengths, standard deviation of 0.36, and coefficient of variation equal to 0.25.

Keywords: cast-in headed anchors, concrete cone failure, uncracked concrete, cracked concrete

Procedia PDF Downloads 177
166 Engaging Students with Special Education Needs through Technology-Enhanced Interactive Activities in Class

Authors: Pauli P.Y. Lai

Abstract:

Students with Special Education Needs (SEN) face many challenges in learning. Various challenges include difficulty in handwriting, slow understanding and assimilation, difficulty in paying attention during class, and lack of communication skills. To engage students with Special Education Needs in class with general students, Blackboard Collaborate is used as a teaching and learning tool to deliver a lecture with interactive activities. Blackboard Collaborate provides a good platform to create and enhance active, collaborative and interactive learning experience whereby the SEN students can easily interact with their general peers and the instructor by using the features of drawing on a virtual whiteboard, file sharing, classroom chatter, breakout room, hand-raising feature, polling, etc. By integrating a blended learning approach with Blackboard Collaborate, the students with Special Education Needs could engage in interactive activities with ease in class. Our research aims at exploring and discovering the use of Blackboard Collaborate for inclusive education based on a qualitative design with in-depth interviews. Being served in a general education environment, three university students with different kinds of learning disabilities have participated in our study. All participants agreed that functions provided by Blackboard Collaborate have enhanced their learning experiences and helped them learn better. Their academic performances also showed that SEN students could perform well with the help of technology. This research studies different aspects of using Blackboard Collaborate to create an inclusive learning environment for SEN students.

Keywords: blackboard collaborate, enhanced learning experience, inclusive education, special education needs

Procedia PDF Downloads 108
165 Design of the Ice Rink of the Future

Authors: Carine Muster, Prina Howald Erika

Abstract:

Today's ice rinks are important energy consumers for the production and maintenance of ice. At the same time, users demand that the other rooms should be tempered or heated. The building complex must equally provide cooled and heated zones, which does not translate as carbon-zero ice rinks. The study provides an analysis of how the civil engineering sector can significantly impact minimizing greenhouse gas emissions and optimizing synergies across an entire ice rink complex. The analysis focused on three distinct aspects: the layout, including the volumetric layout of the premises present in an ice rink; the materials chosen that can potentially use the most ecological structural approach; and the construction methods based on innovative solutions to reduce carbon footprint. The first aspect shows that the organization of the interior volumes and defining the shape of the rink play a significant role. Its layout makes the use and operation of the premises as efficient as possible, thanks to the differentiation between heated and cooled volumes while optimising heat loss between the different rooms. The sprayed concrete method, which is still little known, proves that it is possible to achieve the strength of traditional concrete for the structural aspect of the load-bearing and non-load-bearing walls of the ice rink by using materials excavated from the construction site and providing a more ecological and sustainable solution. The installation of an empty sanitary space underneath the ice floor, making it independent of the rest of the structure, provides a natural insulating layer, preventing the transfer of cold to the rest of the structure and reducing energy losses. The addition of active pipes as part of the foundation of the ice floor, coupled with a suitable system, gives warmth in the winter and storage in the summer; this is all possible thanks to the natural heat in the ground. In conclusion, this study provides construction recommendations for future ice rinks with a significantly reduced energy demand, using some simple preliminary design concepts. By optimizing the layout, materials, and construction methods of ice rinks, the civil engineering sector can play a key role in reducing greenhouse gas emissions and promoting sustainability.

Keywords: climate change, energy optimization, green building, sustainability

Procedia PDF Downloads 32
164 Control Algorithm for Home Automation Systems

Authors: Marek Długosz, Paweł Skruch

Abstract:

One of purposes of home automation systems is to provide appropriate comfort to the users by suitable air temperature control and stabilization inside the rooms. The control of temperature level is not a simple task and the basic difficulty results from the fact that accurate parameters of the object of control, that is a building, remain unknown. Whereas the structure of the model is known, the identification of model parameters is a difficult task. In this paper, a control algorithm allowing the present temperature to be reached inside the building within the specified time without the need to know accurate parameters of the building itself is presented.

Keywords: control, home automation system, wireless networking, automation engineering

Procedia PDF Downloads 579
163 Optimal Pricing Based on Real Estate Demand Data

Authors: Vanessa Kummer, Maik Meusel

Abstract:

Real estate demand estimates are typically derived from transaction data. However, in regions with excess demand, transactions are driven by supply and therefore do not indicate what people are actually looking for. To estimate the demand for housing in Switzerland, search subscriptions from all important Swiss real estate platforms are used. These data do, however, suffer from missing information—for example, many users do not specify how many rooms they would like or what price they would be willing to pay. In economic analyses, it is often the case that only complete data is used. Usually, however, the proportion of complete data is rather small which leads to most information being neglected. Also, the data might have a strong distortion if it is complete. In addition, the reason that data is missing might itself also contain information, which is however ignored with that approach. An interesting issue is, therefore, if for economic analyses such as the one at hand, there is an added value by using the whole data set with the imputed missing values compared to using the usually small percentage of complete data (baseline). Also, it is interesting to see how different algorithms affect that result. The imputation of the missing data is done using unsupervised learning. Out of the numerous unsupervised learning approaches, the most common ones, such as clustering, principal component analysis, or neural networks techniques are applied. By training the model iteratively on the imputed data and, thereby, including the information of all data into the model, the distortion of the first training set—the complete data—vanishes. In a next step, the performances of the algorithms are measured. This is done by randomly creating missing values in subsets of the data, estimating those values with the relevant algorithms and several parameter combinations, and comparing the estimates to the actual data. After having found the optimal parameter set for each algorithm, the missing values are being imputed. Using the resulting data sets, the next step is to estimate the willingness to pay for real estate. This is done by fitting price distributions for real estate properties with certain characteristics, such as the region or the number of rooms. Based on these distributions, survival functions are computed to obtain the functional relationship between characteristics and selling probabilities. Comparing the survival functions shows that estimates which are based on imputed data sets do not differ significantly from each other; however, the demand estimate that is derived from the baseline data does. This indicates that the baseline data set does not include all available information and is therefore not representative for the entire sample. Also, demand estimates derived from the whole data set are much more accurate than the baseline estimation. Thus, in order to obtain optimal results, it is important to make use of all available data, even though it involves additional procedures such as data imputation.

Keywords: demand estimate, missing-data imputation, real estate, unsupervised learning

Procedia PDF Downloads 259
162 Food Safety and Quality Assurance and Skills Development among Farmers in Georgia

Authors: Kakha Nadiardze, Nana Phirosmanashvili

Abstract:

The goal of this paper is to present the problems of lack of information among farmers in food safety. Global food supply chains are becoming more and more diverse, making traceability systems much harder to implement across different food markets. In this abstract, we will present our work for analyzing the key developments in Georgian food market from regulatory controls to administrative procedures to traceability technologies. Food safety and quality assurance are most problematic issues in Georgia as food trade networks become more and more complex, food businesses are under more and more pressure to ensure that their products are safe and authentic. The theme follow-up principles from farm to table must be top-of-mind for all food manufacturers, farmers and retailers. Following the E. coli breakout last year, as well as more recent cases of food mislabeling, developments in food traceability systems is essential to food businesses if they are to present a credible brand image. Alongside this are the ever-developing technologies in food traceability networks, technologies that manufacturers and retailers need to be aware of if they are to keep up with food safety regulations and avoid recall. How to examine best practice in food management is the main question in order to protect company brand through safe and authenticated food. We are working with our farmers to work with our food safety experts and technology developers throughout the food supply chain. We provide time by time food analyses on heavy metals, pesticide residues and different pollutants. We are disseminating information among farmers how the latest food safety regulations will impact the methods to use to identify risks within their products.

Keywords: food safety, GMO, LMO, E. coli, quality

Procedia PDF Downloads 476
161 Corrosion Mitigation in Gas Facilities Piping Through the Use of FBE Coated Pipes and Corrosion Resistant Alloy Girth Welds

Authors: Fadi Chammas, Saad Alkhaldi, Tariq Alghamdi, Stefano Alexandirs

Abstract:

The operating conditions and corrosive nature of the process fluid in the Haradh and Hawiyah areas are subjecting facility piping to undesirable corrosion phenomena. Therefore, production headers inside remote headers have been internally cladded with high alloy material to mitigate the corrosion damage mechanism. Corrosion mitigation in the jump-over lines, constructed between the existing flowlines and the newly constructed facilities to provide operational flexibility, is proposed. This corrosion mitigation system includes the application of fusion bond epoxy (FBE) coating on the internal surface of the pipe and depositing corrosion-resistant alloy (CRA) weld layers at pipe and fittings ends to protect the carbon steel material. In addition, high alloy CRA weld material is used to deposit the girth weld between the 90-degree elbows and mating internally coated segments. A rigorous testing and qualification protocol was established prior to actual adoption at the Haradh and Hawiyah Field Gas Compression Program, currently being executed by Saudi Aramco. The proposed mitigation system, aimed at applying the cladding at the ends of the internally FBE coated pipes/elbows, will resolve field joint coating challenges, eliminate the use of approximately (1700) breakout flanges, and prevent the potential hydrocarbon leaks.

Keywords: pipelines, corrosion, cost-saving, project completion

Procedia PDF Downloads 92
160 The Usefulness of Medical Scribes in the Emengecy Department

Authors: Victor Kang, Sirene Bellahnid, Amy Al-Simaani

Abstract:

Efficient documentation and completion of clerical tasks are pillars of efficient patient-centered care in acute settings such as the emergency department (ED). Medical scribes aid physicians with documentation, navigation of electronic health records, results gathering, and communication coordination with other healthcare teams. However, the use of medical scribes is not widespread, with some hospitals even continuing to discontinue their programs. One reason for this could be the lack of studies that have outlined concrete improvements in efficiency and patient and provider satisfaction in emergency departments before and after incorporating scribes. Methods: We conducted a review of the literature concerning the implementation of a medical scribe program and emergency department performance. For this review, a narrative synthesis accompanied by textual commentaries was chosen to present the selected papers. PubMed was searched exclusively. Initially, no date limits were set, but seeing as the electronic medical record was officially implemented in Canada in 2013, studies published after this date were preferred as they provided insight into the interplay between its implementation and scribes on quality improvement. Results: Throughput, efficiency, and cost-effectiveness were the most commonly used parameters in evaluating scribes in the Emergency Department. Important throughput metrics, specifically door-to-doctor and disposition time, were significantly decreased in emergency departments that utilized scribes. Of note, this was shown to be the case in community hospitals, where the burden of documentation and clerical tasks would fall directly upon the attending physician. Academic centers differ in that they rely heavily on residents and students; so the implementation of scribes has been shown to have limited effect on these metrics. However, unique to academic centers was the provider’s perception of incrased time for teaching was unique to academic centers. Consequently, providers express increased work satisfaction in relation to time spent with patients and in teaching. Patients, on the other hand, did not demonstrate a decrease in satisfaction in regards to the care that was provided, but there was no significant increase observed either. Of the studies we reviewed, one of the biggest limitations was the lack of significance in the data. While many individual studies reported that medical scribes in emergency rooms improved relative value units, patient satisfaction, provider satisfaction, and increased number of patients seen, there was no statistically significant improvement in the above criteria when compiled in a systematic review. There is also a clear publication bias; very few studies with negative results were published. To prove significance, data from more emergency rooms with scribe programs would need to be compiled which also includes emergency rooms who did not report noticeable benefits. Furthermore, most data sets focused only on scribes in academic centers. Conclusion: Ultimately, the literature suggests that while emergency room physicians who have access to medical scribes report higher satisfaction due to lower clerical burdens and can see more patients per shift, there is still variability in terms of patient and provider satisfaction. Whether or not this variability exists due to differences in training (in-house trainees versus contractors), population profile (adult versus pediatric), setting (academic versus community), or which shifts scribe work cannot be determined based on the studies that exist. Ultimately, more scribe programs need to be evaluated to determine whether these variables affect outcomes and prove whether scribes significantly improve emergency room efficiency.

Keywords: emergency medicine, medical scribe, scribe, documentation

Procedia PDF Downloads 69
159 Evaluation of Musical Conductor Exposure to Noise

Authors: Ahmed Saleh Summan

Abstract:

This article presents the results of a technical report on the evaluation of occupational noise exposures among a musical conductor in a musical rehearsal hall (party–center). A calibrated noise dosimeter was used to measure the personal exposure of a music teacher/conductor for 8 hours in two days of rehearsal involving 90 players. Results showed that noise exposure levels were much higher than the permissible levels regulated 85dBA/8hr by NIOSH. In fact, the first day of measurements recorded the highest exposure levels (91 dBA). A number of factors contributed to these results, such as players number, types of instruments used, and activities. Noise control measures were recommended to solve this situation.

Keywords: noise exposure, music conductors, occupational noise, noise in rooms

Procedia PDF Downloads 82
158 Intelligent IT Infrastructure in the Gas and Oil Industry

Authors: Ahmad Fahad Alotaibi, Khalid Hamed Hajri, Humoud Hudiban Rashidi

Abstract:

Intelligent information technology infrastructure is considered one of the enablers to enhance digital transformation in the gas and oil fields to optimize IT infrastructure reliability by supporting operations and maintenance in a safe and secure method to optimize resources. Smart IT buildings, communication rooms and shelters with intelligent technologies can strengthen the performance and profitability of gas and oil companies by ensuring business continuity. This paper describes the advantages of deploying intelligent IT infrastructure in the oil and gas industry by illustrating its positive impacts on some development aspects, for instance, operations, maintenance, safety, security and resource optimization. Moreover, it highlights the challenges and difficulties of providing smart IT services in a remote area and proposes solutions to overcome such difficulties.

Keywords: intelligent IT infrastructure, remote areas, oil and gas field, digitalization

Procedia PDF Downloads 23
157 Assessment of the Occupancy’s Effect on Speech Intelligibility in Al-Madinah Holy Mosque

Authors: Wasim Orfali, Hesham Tolba

Abstract:

This research investigates the acoustical characteristics of Al-Madinah Holy Mosque. Extensive field measurements were conducted in different locations of Al-Madinah Holy Mosque to characterize its acoustic characteristics. The acoustical characteristics are usually evaluated by the use of objective parameters in unoccupied rooms due to practical considerations. However, under normal conditions, the room occupancy can vary such characteristics due to the effect of the additional sound absorption present in the room or by the change in signal-to-noise ratio. Based on the acoustic measurements carried out in Al-Madinah Holy Mosque with and without occupancy, and the analysis of such measurements, the existence of acoustical deficiencies has been confirmed.

Keywords: Al-Madinah Holy Mosque, mosque acoustics, speech intelligibility, worship sound

Procedia PDF Downloads 145
156 Thermal and Visual Comfort Assessment in Office Buildings in Relation to Space Depth

Authors: Elham Soltani Dehnavi

Abstract:

In today’s compact cities, bringing daylighting and fresh air to buildings is a significant challenge, but it also presents opportunities to reduce energy consumption in buildings by reducing the need for artificial lighting and mechanical systems. Simple adjustments to building form can contribute to their efficiency. This paper examines how the relationship between the width and depth of the rooms in office buildings affects visual and thermal comfort, and consequently energy savings. Based on these evaluations, we can determine the best location for sedentary areas in a room. We can also propose improvements to occupant experience and minimize the difference between the predicted and measured performance in buildings by changing other design parameters, such as natural ventilation strategies, glazing properties, and shading. This study investigates the condition of spatial daylighting and thermal comfort for a range of room configurations using computer simulations, then it suggests the best depth for optimizing both daylighting and thermal comfort, and consequently energy performance in each room type. The Window-to-Wall Ratio (WWR) is 40% with 0.8m window sill and 0.4m window head. Also, there are some fixed parameters chosen according to building codes and standards, and the simulations are done in Seattle, USA. The simulation results are presented as evaluation grids using the thresholds for different metrics such as Daylight Autonomy (DA), spatial Daylight Autonomy (sDA), Annual Sunlight Exposure (ASE), and Daylight Glare Probability (DGP) for visual comfort, and Predicted Mean Vote (PMV), Predicted Percentage of Dissatisfied (PPD), occupied Thermal Comfort Percentage (occTCP), over-heated percent, under-heated percent, and Standard Effective Temperature (SET) for thermal comfort that are extracted from Grasshopper scripts. The simulation tools are Grasshopper plugins such as Ladybug, Honeybee, and EnergyPlus. According to the results, some metrics do not change much along the room depth and some of them change significantly. So, we can overlap these grids in order to determine the comfort zone. The overlapped grids contain 8 metrics, and the pixels that meet all 8 mentioned metrics’ thresholds define the comfort zone. With these overlapped maps, we can determine the comfort zones inside rooms and locate sedentary areas there. Other parts can be used for other tasks that are not used permanently or need lower or higher amounts of daylight and thermal comfort is less critical to user experience. The results can be reflected in a table to be used as a guideline by designers in the early stages of the design process.

Keywords: occupant experience, office buildings, space depth, thermal comfort, visual comfort

Procedia PDF Downloads 153
155 Solving Operating Room Scheduling Problem by Using Dispatching Rule

Authors: Yang-Kuei Lin, Yin-Yi Chou

Abstract:

In this research, we have considered operating room scheduling problem. The objective is to minimize total operating cost. The total operating cost includes idle cost and overtime cost. We have proposed a dispatching rule that can guarantee to find feasible solutions for the studied problem efficiently. We compared the proposed dispatching rule with the optimal solutions found by solving Inter Programming, and other solutions found by using modified existing dispatching rules. The computational results indicates that the proposed heuristic can find near optimal solutions efficiently.

Keywords: assignment, dispatching rule, operation rooms, scheduling

Procedia PDF Downloads 207