Search results for: Vibhu Dhawan
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 7

Search results for: Vibhu Dhawan

7 Implementing a Comprehensive Emergency Care and Life Support Course in a Low- and Middle-Income Country Setting: A Survey of Learners in India

Authors: Vijayabhaskar Reddy Kandula, Peter Provost Taillac, Balasubramanya M. A., Ram Krishnan Nair, Gokul Toshnival, Vibhu Dhawan, Vijaya Karanam, Buffy Cramer

Abstract:

Introduction: The lack of Emergency Care Services (ECS) is a cause of extensive and serious public health problems in low- and middle-income countries (LMIC), Many LMIC countries have ambulance services that allow timely transfer of ill patients but due to poor care during the ‘Golden Hour’ many deaths occur which are otherwise preventable. Lack of adequate training as evidenced by a study in India is a major reason for poor care during the ‘Golden Hour’. Adapting developed country models which includes staffing specialty-trained doctors in emergency care, is neither feasible nor guarantees cost-effective ECS. Methods: Based on our assessment and felt needs by first-line doctors providing emergency care in 2014, Rajiv Gandhi Health Sciences University’s JeevaRaksha Trust in partnership with the University of Utah, USA, designed, piloted and successfully implemented a 4-day Comprehensive-Emergency Care and Life Support course (C-ECLS) for allopathic doctors. 1730 doctors completed the 4-day course between June 2014 and December- 2020. Subsequently, we conducted a survey to investigate the utilization rates and usefulness of the training. 1662 were contacted but only 309 completed the survey. The respondents had the following designations: Senior faculty (33%), junior faculty (25), Resident (16%), Private-Practitioners (8%), Medical-Officer (16%) and not-working (11%). 51% were generalists (51%) and the rest were specialists (>30 specialties). Results: 97% (271/280) felt they are better doctors because of C-ECLS. 79% (244/309) reported that training helped to save life- specialists more likely than generalists (91% v/s 68%. P<0.05). 64% agreed that they were confident of managing COVID-19 symptomatic patients better because of C-ECLS. 27% (77) were neutral; 9% (24) disagreed. 66% agreed that training helps to be confident in managing COVID-19 critically ill patients. 26% (72) were neutral; 8% (23) disagreed. Frequency of use of C-ECLS skills: Hemorrhage-control (70%), Airway (67%), circulation skills (62%), Safe-transport and communication (60%), managing critically ill patients (58%), cardiac arrest (51%), Trauma (49%), poisoning/animal bites/stings (44%), neonatal-resuscitation (39%), breathing (36%), post-partum-hemorrhage and eclampsia (35%). Among those who used the skills, the majority (ranging from (88%-94%) reported that they were able to apply the skill more effectively because of ECLS training. Conclusion: JeevaRaksha’s C-ECLS is the world’s first comprehensive training. It improves the confidence of front-line doctors and enables them to provide quality care during the ‘Golden Hour’ of emergency. It also prepares doctors to manage unknown emergencies (e.g., COVID-19). C-ECLS was piloted in Morocco, and Uzbekistan and implemented countrywide in Bhutan. C-ECLS is relevant to most settings and offers a replicable model across LMIC.

Keywords: comprehensive emergency care and life support, training, capacity building, low- and middle-income countries, developing countries

Procedia PDF Downloads 32
6 Effect of Curing Temperature on Mechanical Properties of Jute Fiber Reinforced Polylactic Acid Based Green Composite

Authors: Sehijpal Singh Khangura, Jai Inder Preet Singh, Vikas Dhawan

Abstract:

Global warming, growing awareness of the environment, waste management issues, dwindling fossil resources, and rising oil prices resulted to increase the research in the materials that are friendly to our health and environment. Due to these reasons, green products are increasingly being promoted for sustainable development. In this work, fully biodegradable green composites have been developed using jute fibers as reinforcement and poly lactic acid as matrix material by film stacking technique. The effect of curing temperature during development of composites ranging from 160 °C, 170 °C, 180 °C and 190 °C was investigated for various mechanical properties. Results obtained from various tests indicate that impact strength decreases with an increase in curing temperature, but tensile and flexural strength increases till 180 °C, thereafter both the properties decrease. This study gives an optimum curing temperature for the development of jute/PLA composites.

Keywords: natural fibers, polymer matrix composites, jute, compression molding, biodegradation

Procedia PDF Downloads 120
5 Audit on the Use of T-MACS Decision Aid for Patients Presenting to ED with Chest Pain

Authors: Saurav Dhawan, Sanchit Bansal

Abstract:

Background T-MACS is a computer-based decision aid that ‘rules in’ and ‘rules out’ ACS using a combination of the presence or absence of six clinical features with only one biomarker measured on arrival: hs-cTnT. T-MACS had 99.3% negative predictive value and 98.7% sensitivity for ACS, ‘ruling out’ ACS in 40% of patients while ‘ruling in’ 5% at the highest risk. We aim at benchmarking the use of T-MACS which could help to conserve healthcare resources, facilitate early discharges, and ensure safe practice. Methodology Randomized retrospective data collection (n=300) was done from ED electronic records across 3 hospital sites within MFT over a period of 2 months. Data was analysed and compared by percentage for the usage of T-MACS, number of admissions/discharges, and in days for length of stay in hospital. Results MRI A&E had the maximum compliance with the use of T-MACS in the trust at 66%, with minimum admissions (44%) and an average length of stay of 1.825 days. NMG A&E had an extremely low compliance rate (8 %), with 75% admission and 3.387 days as the average length of stay. WYT A&E had no TMACS recorded, with a maximum of 79% admissions and the longest average length of stay at 5.07 days. Conclusion All three hospital sites had a RAG rating of ‘RED’ as per the compliance levels. The assurance level was calculated as ‘Very Limited’ across all sites. There was a positive correlation observed between compliance with TMACS and direct discharges from ED, thereby reducing the average length of stay for patients in the hospital.

Keywords: ACS, discharges, ED, T-MACS

Procedia PDF Downloads 23
4 Virtual Screening of Potential Inhibitors against Efflux Pumps of Mycobacterium tuberculosis

Authors: Gagan Dhawan

Abstract:

Mycobacterium tuberculosis was described as ‘captain of death’ with an inherent property of multiple drug resistance majorly caused by the competent mechanism of efflux pumps. In this study, various open source tools combining chemo-informatics with bioinformatics were used for efficient in-silico drug designing. The efflux pump, Rv1218c, belonging to the ABC transporter superfamily, which is predicted to be a tetronasin-transporter in M. tuberculosis was targeted. Recent studies have shown that Rv1218c forms a complex with two more efflux pumps (Rv1219c and Rv1217c) to provide multidrug resistance to the bacterium. The 3D structure of the protein was modeled (as the structure was unavailable in the previously collected databases on this gene). The TMHMM analysis of this protein in TubercuList has shown that this protein is present in the outer membrane of the bacterium. Virtual screening of compounds from various publically available chemical libraries was performed on the M. tuberculosis protein using various open source tools. These ligands were further assessed where various physicochemical properties were evaluated and analyzed. On comparison of different physicochemical properties, toxicity and docking, the ligand 2-(hydroxymethyl)-6-[4, 5, 6-trihydroxy-2-(hydroxymethyl) tetrahydropyran-3-yl] oxy-tetrahydropyran-3, 4, 5-triol was found to be best suited for further studies.

Keywords: drug resistance, efflux pump, molecular docking, virtual screening

Procedia PDF Downloads 347
3 Characterization of Mg/Sc System for X-Ray Spectroscopy in the Water Window Range

Authors: Hina Verma, Karine Le Guen, Mohammed H. Modi, Rajnish Dhawan, Philippe Jonnard

Abstract:

Periodic multilayer mirrors have potential application as optical components in X-ray microscopy, particularly working in the water window region. The water window range, located between the absorption edges of carbon (285 eV) and oxygen (530eV), along with the presence of nitrogen K absorption edge (395 eV), makes it a powerful method for imaging biological samples due to the natural optical contrast between water and carbon. We characterized bilayer, trilayer, quadrilayer, and multilayer systems of Mg/Sc with ZrC thin layers introduced as a barrier layer and capping layer prepared by ion beam sputtering. The introduction of ZrC as a barrier layer is expected to improve the structure of the Mg/Sc system. The ZrC capping layer also prevents the stack from oxidation. The structural analysis of the Mg/Sc systems was carried out by using grazing incidence X-ray reflectivity (GIXRR) to obtain non-destructively a first description of the structural parameters, thickness, roughness, and density of the layers. Resonant soft X-ray reflectivity measurements in the vicinity of Sc L-absorption edge were performed to investigate and quantify the atomic distribution of deposited layers. Near absorption edge, the atomic scattering factor of an element changes sharply depending on its chemical environment inside the structure.

Keywords: buried interfaces, resonant soft X-ray reflectivity, X-ray optics, X-ray reflectivity

Procedia PDF Downloads 129
2 Differential Expression of Biomarkers in Cancer Stem Cells and Side Populations in Breast Cancer Cell Lines

Authors: Dipali Dhawan

Abstract:

Cancerous epithelial cells are confined to a primary site by the continued expression of adhesion molecules and the intact basal lamina. However, as the cancer progresses some cells are believed to undergo an epithelial-mesenchymal transition (EMT) event, leading to increased motility, invasion and, ultimately, metastasis of the cells from the primary tumour to secondary sites within the body. These disseminated cancer cells need the ability to self-renew, as stem cells do, in order to establish and maintain a heterogeneous metastatic tumour mass. Identification of the specific subpopulation of cancer stem cells amenable to the process of metastasis is highly desirable. In this study, we have isolated and characterized cancer stem cells from luminal and basal breast cancer cell lines (MDA-MB-231, MDA-MB-453, MDA-MB-468, MCF7 and T47D) on the basis of cell surface markers CD44 and CD24; as well as Side Populations (SP) using Hoechst 33342 dye efflux. The isolated populations were analysed for epithelial and mesenchymal markers like E-cadherin, N-cadherin, Sfrp1 and Vimentin by Western blotting and Immunocytochemistry. MDA-MB-231 cell lines contain a major population of CD44+CD24- cells whereas MCF7, T47D and MDA-MB-231 cell lines show a side population. We observed higher expression of N-cadherin in MCF-7 SP cells as compared to MCF-7NSP (Non-side population) cells suggesting that the SP cells are mesenchymal like cells and hence express increased N-cadherin with stem cell-like properties. There was an expression of Sfrp1 in the MCF7- NSP cells as compared to no expression in MCF7-SP cells, which suggests that the Wnt pathway is expressed in the MCF7-SP cells. The mesenchymal marker Vimentin was expressed only in MDA-MB-231 cells. Hence, understanding the breast cancer heterogeneity would enable a better understanding of the disease progression and therapeutic targeting.

Keywords: cancer stem cells, epithelial to mesenchymal transition, biomarkers, breast cancer

Procedia PDF Downloads 484
1 Study of Ion Density Distribution and Sheath Thickness in Warm Electronegative Plasma

Authors: Rajat Dhawan, Hitendra K. Malik

Abstract:

Electronegative plasmas comprising electrons, positive ions, and negative ions are advantageous for their expanding applications in industries. In plasma cleaning, plasma etching, and plasma deposition process, electronegative plasmas are preferred because of relatively less potential developed on the surface of the material under investigation. Also, the presence of negative ions avoid the irregularity in etching shapes and also enhance the material working during the fabrication process. The interaction of metallic conducting surface with plasma becomes mandatory to understand these applications. A metallic conducting probe immersed in a plasma results in the formation of a thin layer of charged species around the probe called as a sheath. The density of the ions embedded on the surface of the material and the sheath thickness are the important parameters for the surface-plasma interaction. Sheath thickness will give rise to the information of affected plasma region due to conducting surface/probe. The knowledge of the density of ions in the sheath region is advantageous in plasma nitriding, and their temperature is equally important as it strongly influences the thickness of the modified layer during surface plasma interaction. In the present work, we considered a negatively biased metallic probe immersed in a warm electronegative plasma. For this system, we adopted the continuity equation and momentum transfer equation for both the positive and negative ions, whereas electrons are described by Boltzmann distribution. Finally, we use the Poisson’s equation. Here, we assumed the spherical geometry for small probe radius. Poisson’s equation reveals the behaviour of potential surrounding a conducting metallic probe along with the use of the continuity and momentum transfer equations, with the help of proper boundary conditions. In turn, it gives rise to the information about the density profile of charged species and most importantly the thickness of the sheath. By keeping in mind, the well-known Bohm-Sheath criterion, all calculations are done. We found that positive ion density decreases with an increase in positive ion temperature, whereas it increases with the higher temperature of the negative ions. Positive ion density decreases as we move away from the center of the probe and is found to show a discontinuity at a particular distance from the center of the probe. The distance where discontinuity occurs is designated as sheath edge, i.e., the point where sheath ends. These results are beneficial for industrial applications, as the density of ions embedded on material surface is strongly affected by the temperature of plasma species. It has a drastic influence on the surface properties, i.e., the hardness, corrosion resistance, etc. of the materials.

Keywords: electronegative plasmas, plasma surface interaction positive ion density, sheath thickness

Procedia PDF Downloads 108